Attachment D - Site and Design Plans Additional Scope of Work.pdf
PDF 36 MB Posted
- Attached to
- Fairington Road Sidewalk Project
- Solicitation number
- CITB-0014-25 REBID
- Issued by
- Dekalb County, Georgia
About this file
This document is a comprehensive set of civil engineering design plans and technical specifications for the Fairington Road Sidewalk Project, prepared by Stantec Consulting Services, Inc. for the City of Stonecrest, Georgia. The project involves constructing a new 5-foot concrete sidewalk along Fairington Road, spanning approximately 2,275 linear feet from station 10+00 to station 32+75, and includes additional infrastructure improvements such as new curb and gutter, a bus shelter, and various erosion control measures. The project site covers 3.12 acres, with 1.57 acres of disturbed area, and is located just south of Highway I-20 in DeKalb County.
The project is funded through the Community Development Block Grant (CDBG) Program and is subject to federal regulations including the Davis-Bacon Act, Section 3, and other labor standards. The design plans include detailed specifications for utility relocations, storm drainage, erosion control, and construction phasing, with specific requirements for sediment control, vegetation stabilization, and site restoration. The project involves coordination with multiple utility providers, including Atlanta Gas Light, AT&T, DeKalb County Water and Sewer, and Georgia Power, and requires careful management of existing infrastructure and environmental considerations, particularly near an unnamed tributary to Pole Bridge Creek.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P:(770) 224-0200
HARI KARIKARAN
24 HOUR CONTACT
Issued
Revision
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Project Number: 234300052
FAIRINGTON ROAD SIDEWALK DESIGN
STANTEC CONSULTING SERVICES, INC.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
TEL. (770) 493-0450
WWW.STANTEC.COM
CONTACT:KEVIN W. CLARK, P.E.
DEVELOPER / CLIENT:
CITY OF STONECREST
3120 STONECREST BLVD #190
STONECREST, GA 30338
CONTACT: HARI KARIKARAN
TOTAL SITE AREA: 3.12 AC
DISTURBED AREA: 1.57 AC
FAIRINGTON ROAD
SITE LOCATION
N.T.S.
N
FAIRINGTON ROAD
BEGIN STA 10+00
END STA 32+75
1ST LDP SUBMITTAL BDG KWC 2023.08.11
PROJECT DESCRIPTION:
THIS PROJECT CONSISTS OF THE ADDITION OF A NEW SIDEWALK, NEW CURB AND GUTTER, AND
A NEW BUS SHELTER ALONG FAIRINGTON ROAD.
THE PROJECT IS LOCATED WITHIN THE CITY OF STONECREST JUST SOUTH OF HIGHWAY I-20. THE SITE IS BOUNDED IN THE NORTH BY HIGHWAY I-20, TO THE SOUTH ARE RESIDENTIAL LOTS AND UNDEVELOPED WOODED AREAS. FAIRINGTON ROAD CONTINUES TO THE WEST AND EAST.LAND LOTS 56, 55, 73 & 74 OF
THE 16TH DISTRICT, CITY OF STONECREST,
DEKALB COUNTY, GEORGIA
REVIEWING AGENCY
JURISDICTION: CITY OF STONECREST, GA
Sheet List Table Sheet Number Sheet Title
C000 COVER SHEET
C001 GENERAL NOTES
C002 LEGENDS
C200 TYPICAL SECTION
C300 CONSTRUCTION LAYOUT
C301 MAINLINE PLAN
C302 MAINLINE PLAN
C303 MAINLINE PLAN
C304 MAINLINE PLAN
C305 MAINLINE PLAN
C311 STORM DRAIN PROFILES
C321 CROSS SECTIONS
C322 CROSS SECTIONS
C323 CROSS SECTIONS
C324 CROSS SECTIONS
C325 CROSS SECTIONS
C326 CROSS SECTIONS
C401 UTILITY PLAN
C402 UTILITY PLAN
C403 UTILITY PLAN
C404 UTILITY PLAN
C405 UTILITY PLAN
C501 CONSTRUCTION DETAILS
C502 CONSTRUCTION DETAILS
C503 CONSTRUCTION DETAILS
C700 EROSION CONTROL PLAN PHASE 1 & 2
C701 EROSION CONTROL PLAN PHASE 1 & 2
C702 EROSION CONTROL PLAN PHASE 3
C703 EROSION CONTROL PLAN PHASE 3
C704 NPDES NOTES
C705 EROSION CONTROL DETAILS
C706 EROSION CONTROL DETAILS
C707 EROSION CONTROL DETAILS
Note
C504 CONSTRUCTION DETAILS
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
C505 CONSTRUCTION DETAILS
C211 C212
SIGHT DISTANCE PLAN 1 EXHIBIT
SIGHT DISTANCE PLAN 2 EXHIBIT
C001
GENERAL NOTES
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-001GN
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-0 gn
.1
1.
:4
1:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
1. TOTAL SITE AREA = 3.12 AC, DISTURBED AREA = 1.57 AC
2. ELEVATIONS ARE BASED ON MEAN SEA LEVEL.
3. EXISTING CONDITIONS FROM FIELD RUN TOPOGRAPHY & BOUNDARY PREPARED BY KCI, FEBRUARY 02, 2024.
4. CONTOUR INTERVALS ARE 1.0 FEET.
5. ALL TREE SAVE AREAS AND BUFFERS ARE TO BE CLEARLY IDENTIFIED WITH FLAGGING AND/OR FENCING
PRIOR TO COMMENCEMENT OF ANY LAND DISTURBANCE.
6. CLEARING AND GRUBBING: ON ALL AREAS WHERE GRADING, EXCAVATING AND FILL ARE TO BE DONE, ALL
TIMBER BRUSH, STUMPS, ROOTS, RUBBISH AND ORGANIC MATERIALS SHALL BE REMOVED. STUMP HOLES SHALL BE FILLED WITH COMPACTED CLEAN SOIL. A MINIMUM OF SIX INCHES MUST BE CUT BELOW EXISTING GRADE FOR ENTIRE AREA RECEIVING FILL. STORM DETENTION MEASURES MUST BE ACCOMPLISHED CONCURRENT WITH THIS PHASE. REFER TO THE CURRENT EDITION OF THE MANUAL FOR EROSION AND
SEDIMENT CONTROL.
7. ALL EARTHWORK OPERATION SHALL COMPLY WITH REQUIREMENTS OF OSHA CONSTRUCTION STANDARDS, PART 1926, SUBPART P, EXCAVATIONS, TRENCHING, AND SHORING, AND SUBPART O, MOTOR VEHICLES, MECHANIZED EQUIPMENT, AND MARINE OPERATIONS, AND SHALL BE CONDUCTED IN A MANNER ACCEPTABLE
TO THE ENGINEER.
8. FILL MATERIALS SHALL CONSIST OF CLEAN SOIL, FREE OF ORGANIC OR DELETERIOUS MATERIALS, ROCKS, OR BROKEN PIECES OF CONCRETE LARGER THAN THREE INCHES IN SIZE, OR OF ANY OTHER FOREIGN OBJECTS
THAT COULD IMPEDE THE COMPACTION RESULTS.
9. FILL MATERIALS SHALL BE SPREAD EVENLY IN HORIZONTAL LAYERS OF NOT MORE THAN 8 INCHES IN LOOSE LIFTS OVER THE FULL WIDTH OF FILL AND COMPACTED TO AT LEAST 95% MAXIMUM DRY DENSITY BY
STANDARD PROCTOR COMPACTION TEST ASTM D698.
10. MAXIMUM CUT OR FILL SLOPES IS 2H:1V.
11. GRADE TO PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDINGS INTO STORM INLETS.
12. SEE GEOTECHNICAL ENGINEER FOR RECOMMENDATIONS CONCERNING PROPER PLACEMENT AND
COMPACTION OF STRUCTURAL FILL.
13. THE SITE IS NOT LOCATED WITHIN ZONE A 100 YEAR FLOOD ZONE PER FEMA F.I.R.M. MAP 13089C0166J, EFFECTIVE MAY 16 2013.
14. GRADE ALL HANDICAP RAMPS 12H:1V SLOPE MAXIMUM TO TOP OF CURB.
15. ALL SPOT ELEVATIONS ARE FINISHED GRADE ELEVATIONS UNLESS OTHERWISE NOTED.
16. STORM SEWER LINE SHALL BE AS FOLLOWS: CMP, FULLY COATED PER ASTM A444 OR ALUMINIZED TYPE II
WITH REROLLED ENDS & BANDS. RCP, CLASS III PER AASHTO M170 AS INDICATED. UNLESS OTHERWISE
NOTED.
17. ALL CATCH BASINS ARE TO BE PER GDOT STANDARDS.
18. THE INSTALLATION OF ALL EROSION CONTROL MEASURES AND DETENTION FACILITIES SHOULD BE
ACCOMPLISHED PRIOR TO ANY OTHER CONSTRUCTION ON THE SITE AND MAINTAINED UNTIL PERMANENT
GROUND COVER IS ESTABLISHED.
19. COMPACTION OF ALL FILL MATERIAL BETWEEN THE FRONT AND REAR BUILDING LINES TO BE 95% STANDARD PROCTOR MUST BE CERTIFIED BY GEORGIA REGISTERED PROFESSIONAL SOILS ENGINEER PRIOR TO THE INSTALLATION OF CURB. THIS CERTIFICATION WILL BE SUBMITTED TO THE CHIEF OF DEVELOPMENT INSPECTIONS. LOTS WITH TWO (2') OF FILL OR GREATER, AS DELINEATED ON THE CONSTRUCTION PLANS WILL REQUIRE A COMPACTION CERTIFICATION PRIOR TO ISSUANCE OF BUILDING PERMITS. THE ENGINEER WILL ALSO PROVIDE A LETTER LISTING THOSE LOTS THAT REQUIRE COMPACTION CERTIFICATION. THOSE LOTS THAT REQUIRE COMPACTION CERTIFICATION WILL BE INDICATED ON THE FINAL RECORDED PLAT.
20. SATISFACTORY SOILS FOR STRUCTURAL FILL ARE AS FOLLOWS: SOIL CLASSIFICATION GROUPS GW, GP, GM, SW, SP, AND SM ACCORDING TO ASTM D 2487, OR A COMBINATION OF THESE GROUPS; FREE FROM ROCK OR GRAVEL LARGER THAN 2 INCHES IN ANY DIMENSION, DEBRIS, WASTE, FROZEN MATERIALS, VEGETATION, AND OTHER DELETERIOUS MATTER. LIQUID LIMIT: 40. PLASTICITY INDEX: A) UPPER FOUR FEET UNDER A BUILDING AND PAVEMENTS AND TWENTY FEET OUTSIDE: LESS THAN 12. B) BELOW UPPER FOUR FEET UNDER A BUILDING AND PAVEMENTS: LESS THAN 20. C) AREAS TWENTY FEET OUTSIDE BUILDING AND PAVEMENT
AREAS: LESS THAN 30.
GRADING NOTES:
1. SILT FENCE MUST MEET THE REQUIREMENTS OF SECTION 171-TEMPORARY SILT FENCE OF THE
DEPARTMENT OF TRANSPORTATION, STATE OF GEORGIA, STANDARD SPECIFICATION, LATEST
EDITION.
2. ADDITIONAL EROSION CONTROL MEASURES WILL BE EMPLOYED WHERE DETERMINED NECESSARY
BY ACTUAL SITE CONDITIONS TO PREVENT THE RELEASE OF SILT FROM THE SITE.
3. PRIOR TO ANY OTHER CONSTRUCTION, A STABILIZED CONSTRUCTION ENTRANCE SHALL BE
CONSTRUCTED AT EACH ENTRY TO OR EXIT FROM THE SITE.
4. THE CONSTRUCTION EXITS SHALL BE MAINTAINED IN A CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF MUD ONTO PUBLIC RIGHT-OF-WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH STONE, AS CONDITIONS DEMAND, AND REPAIR AND/OR CLEAN-OUT OF ANY STRUCTURES USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, OR TRACKED FROM VEHICLE OFF
SITE ONTO PUBLIC ROADWAY OR INTO STORM DRAIN MUST BE REMOVED.
5. PRIOR TO COMMENCING LAND DISTURBANCE ACTIVITIES, THE LIMITS OF LAND DISTURBANCE SHALL
BE CLEARLY AND ACCURATELY DEMARCATED WITH STAKES, RIBBONS, OR OTHER APPROPRIATE
MEANS. THE LOCATION AND EXTENT OF ALL AUTHORIZED LAND DISTURBANCE SHALL OCCUR
INSIDE THE APPROVED LIMITS INDICATED ON THE APPROVED PLANS.
6. IMMEDIATELY AFTER THE ESTABLISHMENT OF CONSTRUCTION ENTRANCES/EXITS, ALL PERIMETER
EROSION CONTROL DEVICES AND STORM WATER MANAGEMENT DEVICES SHALL BE INSTALLED
PRIOR TO ANY OTHER CONSTRUCTION.
7. THE CONTRACTOR SHALL FURNISH AND MAINTAIN ALL NECESSARY BARRICADES WHILE ROADWAY
FRONTAGE IMPROVEMENTS ARE BEING MADE.
8. THE CONSTRUCTION OF THE SITE WILL INITIATE WITH THE INSTALLATION OF EROSION CONTROL
MEASURES SUFFICIENT TO CONTROL SEDIMENT DEPOSITS AND EROSION. ALL SEDIMENT
CONTROLS WILL BE MAINTAINED UNTIL UPSTREAM GROUND WITHIN THE CONSTRUCTION AREA HAS BEEN COMPLETELY STABILIZED WITH PERMANENT VEGETATION AND ALL ROADS/DRIVEWAYS HAVE
BEEN PAVED.
9. THE LOCATION OF SOME OF THE EROSION CONTROL DEVICES MAY HAVE TO BE ALTERED FROM
THAT SHOWN ON THE APPROVED PLANS IF DRAINAGE PATTERNS DURING CONSTRUCTION ARE
DIFFERENT FROM THE FINAL PROPOSED DRAINAGE PATTERNS. IT IS THE CONTRACTOR'S
RESPONSIBILITY TO ACCOMPLISH EROSION CONTROL FOR ALL DRAINAGE PATTERNS CREATED AT
VARIOUS STAGES DURING CONSTRUCTION. ANY DIFFICULTY IN CONTROLLING EROSION DURING
ANY PHASE OF CONSTRUCTION SHALL BE REPORTED TO THE ENGINEER IMMEDIATELY.
10. ALL SILT BARRIERS MUST BE PLACED AS ACCESS IS OBTAINED DURING CLEARING. NO GRADING
SHALL BE DONE UNTIL SILT BARRIER INSTALLATION AND DETENTION FACILITIES ARE
CONSTRUCTED.
11. CONTRACTOR SHALL MAINTAIN ALL EROSION CONTROL MEASURES UNTIL PERMANENT
VEGETATION HAS BEEN ESTABLISHED. IF SEDIMENT PONDS ARE DEEMED NECESSARY,
CONTRACTOR SHALL CLEAN OUT EACH AS REQUIRED BY ENGINEER OR AUTHORITY HAVING
JURISDICTION INSPECTOR. CONTRACTOR SHALL INSPECT EROSION CONTROL MEASURES AT THE
END OF EACH WORKING DAY TO ENSURE MEASURES ARE FUNCTIONING PROPERLY.
12. THE CONTRACTOR SHALL REMOVE ACCUMULATED SILT WHEN THE SILT IS WITHIN 12" OF THE TOP
OF THE SILT FENCE UTILIZED FOR EROSION CONTROL.
13. FAILURE TO INSTALL, OPERATE OR MAINTAIN ALL EROSION CONTROL MEASURES WILL RESULT IN A POSSIBILITY OF ALL CONSTRUCTION BEING STOPPED ON JOB SITE UNTIL SUCH MEASURES ARE
CORRECTED BACK TO CURRENT STDS.
14. ALL SEWER EASEMENTS DISTURBED MUST BE DRESSED AND GRASSED TO CONTROL EROSION.
15. ALL OPEN SWALES MUST BE GRASSED, AND RIP-RAP MUST BE PLACED AS REQUIRED TO CONTROL
EROSION, A MINIMUM OF 4.5 SQUARE YARDS OF 50 LB STONES SHALL BE PLACED AT ALL
DOWNSTREAM HEADWALLS IMMEDIATELY UPON THE INSTALLATION OF PIPES AND DRAINAGE
DITCHES.
16. SILT BARRIERS TO BE PLACED DOWNSTREAM OF ALL FILL SLOPES.
EROSION CONTROL NOTES:
GENERAL NOTES:
1. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL, STATE AND FEDERAL LAWS AND REGULATIONS
THAT ARE PERTINENT TO THIS WORK.
2. AREAS OUTSIDE THE PROJECT LIMITS ARE DESIGNATED AS RESTRICTED AREAS. THE
CONTRACTOR'S FORCES ARE PROHIBITED FROM ENTERING RESTRICTED AREAS AT ANY TIME,
UNLESS SPECIFICALLY AUTHORIZED BY THE ADJACENT OWNER.
3. THE CONTRACTOR SHALL CONTROL DUST AND DEBRIS FROM HIS OPERATION TO A LEVEL
ACCEPTABLE TO THE COUNTY AT ALL TIMES. THE CONTRACTOR SHALL HAVE ON THE PROJECT
SITE:VACUUM SWEEPERS, WATERING TRUCKS, AND OTHER EQUIPMENT NECESSARY TO CONTROL
DUST AT ALL TIMES. ALL METHODS FOR CONTROLLING DUST SHALL BE SUBJECT TO THE COUNTY'S
APPROVAL. FAILURE TO PROPERLY CONTROL DUST OR TO RESPOND TO ANY REQUEST TO DO SO
WILL RESULT IN CONSTRUCTION ACTIVITIES BEING STOPPED.
4. ALL CONSTRUCTION TRAFFIC SHALL ENTER AND EXIT THE PROJECT AREA AS SHOWN ON THE
PHASED EROSION CONTROL PLAN.
5. THE ROADS USED BY THE CONTRACTOR FOR ACCESS OR HAULING SHALL BE KEPT CLEAN AND ACCESSIBLE TO ALL OTHER TRAFFIC FOR THE ENTIRE DURATION OF THE PROJECT. HAUL TRUCKS MUST BE COVERED AND ANY SPILLAGE OR DEBRIS BUILDUP PROMPTLY REMOVED FROM ALL HAUL
ROUTES ON AIRPORT AND PUBLIC ROADS.
UTILITY NOTES:
1. CONTRACTOR SHALL VERIFY LOCATIONS AND ELEVATIONS OF EXISTING UTILITIES PRIOR TO
BEGINNING CONSTRUCTION. CONTRACTOR SHALL BE SPECIFICALLY RESPONSIBLE FOR
CONTACTING ALL UTILITY COMPANIES THAT MIGHT HAVE EXISTING UTILITIES ON SITE TO
DETERMINE IF ANY EXIST AND HOW TO HANDLE. ENGINEER IS NOT RESPONSIBLE FOR EXISTENCE
OR LOCATION OF UNDERGROUND UTILITIES.
2. CONTRACTOR SHALL CONTACT ALL UTILITY COMPANIES PRIOR TO BEGINNING CONSTRUCTION, AND SHALL BE RESPONSIBLE FOR COORDINATING WITH THEM REGARDING UTILITY LOCATIONS, CONSTRUCTION AND SCHEDULES.
3. ALL CONNECTIONS TO EXISTING UTILITIES AND ALL UTILITY INSTALLATIONS SHALL BE IN
COMPLIANCE WITH REQUIREMENTS OF APPROPRIATE JURISDICTIONAL AGENCIES
4. NEW TESTING IS REQUIRED FOR UTILITIES PER CITY OF STONECREST STANDARDS. THIS INCLUDES, BUT IS NOT LIMITED, TO TV INSPECTION AND PRESSURE TESTING FOR SANITARY SEWER LINES AND
MANHOLES. PRESSURE TESTING AND RECHLORINATION IS REQUIRED FOR THE WATER SYSTEM.
ALL TESTING SHALL BE PER CITY OF STONECREST STANDARDS.
5. SANITARY SEWER SHALL BE AS INDICATED: EITHER PVC, SDR 26 PER ASTM D3034;OR CLASS 50 DUCTILE IRON PIPE PER AWWA C150, PER CITY OF STONECREST SPECIFICATIONS. 6" OR 8" WATER PIPE SHALL BE DUCTILE IRON CLASS 50 AWWA C151 UNLESS OTHERWISE SPECIFIED AND SHALL BE
INSTALLED IN ACCORDANCE WITH CURRENT CITY OF STONECREST STANDARDS. WATER LINES
SMALLER THAN 6" SHALL BE EITHER COPPER TUBE TYPE "K" (SOFT) PER ANSI B16.22.
6. FOR GRADING AND DRAINAGE INFORMATION, SEE GRADING AND DRAINAGE PLAN.
7. EXISTING SERVICES SHOWN WERE OBTAINED FROM AS BUILTS BY OTHERS AND ARE TO BE FIELD
VERIFIED BY THE CONTRACTOR.
8. AT COMPLETION OF SEWER AND WATER CONSTRUCTION, ALL MANHOLES, VALVE BOXES, METERS
AND APPURTENANCES SHALL BE SET FOR PROPER FINISH GRADE AND SHALL BE NOTICEABLY
STAKED AND FLAGGED. SITE UTILITY SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE
TO THE ABOVE ITEMS UNTIL SYSTEM IS ACCEPTED BY OWNER.
9. HYDRANTS AND MAINS SHALL BE INSTALLED AND UNDER PRESSURE BEFORE ANY COMBUSTIBLE
CONSTRUCTION IS STARTED.
10. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING FORTY EIGHT INCHES (48") OF COVER OVER THE PROPOSED WATER MAINS AND EIGHTEEN INCHES (18") OF VERTICAL SEPARATION FROM
OTHER UTILITIES. WHERE LIMITED ROOM EXISTS ABOVE STORM OR SANITARY SEWERS, WATER
LINE SHALL BE CONSTRUCTED UNDERNEATH AT THOSE LOCATIONS, MAINTAINING THE EIGHTEEN INCH (18")SEPARATION REQUIREMENT. ALL UTILITY REQUIREMENTS WILL BE COMPLIED WITH AT CROSSINGS. ADDITIONALLY, A 10' HORIZONTAL SEPARATION IS REQUIRED BETWEEN WATER AND
SANITARY SEWER LINES.
11. ALL SANITARY SEWER DUCTILE IRON PIPE SHALL HAVE PUSH-ON JOINTS PER AWWA C111.
12. RIGID PIPE BEDDING SHALL BE PER ASTM C-1479, FLEXIBLE PIPE BEDDING PER ASTM D-2321.
13. IRRIGATION WATER SERVICE SHALL BE IN METER BOX WITH BACKFLOW PREVENTOR PER
JURISDICTIONAL REQUIREMENTS.
14. SEE DETAIL SHEETS FOR UTILITY DETAILS.
15. ALL WATER LINE CONSTRUCTION SHALL BE TO CITY OF STONECREST SPECIFICATIONS.
16. ALL BACKFILL IN STREETS AND PARKING AREAS FOR PUBLIC SANITARY SEWER MAINS SHALL BE
APPROVED BANK-RUN SAND OR GRAVEL OR CRUSHED STONE FREE FROM LARGE STONES AND
CONTAINING NOT MORE THAN 10% BY WEIGHT OF LOAM OR CLAY.
17. CONTRACTOR SHALL COMPLY WITH REQUIREMENTS SET FORTH IN CITY OF STONECREST
DEVELOPMENT REGULATIONS FOR ALL UTILITY INSTALLATIONS.
MATERIAL NOTES:
1. PRECAST STRUCTURES MAY BE USED AT THE CONTRACTOR'S OPTION. ALL CONCRETE TO HAVE A
MINIMUM 28 DAY COMPRESSIVE STRENGTH OF 3000 P.S.I.
TRAFFIC CONTROL NOTES:
1. THIS WORK CONSISTS OF PROVIDING MAINTENANCE OF TRAFFIC CONTROL DEVICES INCLUDING
FLAGMEN TO INSURE ROADWAY SAFETY BY PROVIDING FOR SAFE ORDERLY AND PREDICTABLE
MOVEMENT OF TRAFFIC THROUGH ALL ADJACENT PUBLIC ROADS AND THE AREAS TO BE
CONSTRUCTED. ALL TRAFFIC CONTROLS DEVICES SHALL BE AS REQUIRED BY THE MANUAL ON
UNIFORM TRAFFIC CONTROL DEVICES (MUTCD), LATEST EDITION, STATE AND LOCAL AGENCIES, OR
AS SHOWN BY THE CONSTRUCTION DRAWINGS, WHICHEVER IS MORE STRINGENT.
2. CONTRACTOR SHALL SUBMIT TO ENGINEER FOR HIS APPROVAL A COMPREHENSIVE PLAN
DETAILING HOW TRAFFIC WILL BE MAINTAINED UNDER THIS CONTRACT. CONSTRUCTION
AFFECTING TRAFFIC SHALL NOT COMMENCE UNTIL THIS PLAN IS APPROVED.
3. THE TRAFFIC CONTROL PLAN SHALL INCLUDE ALL REQUIRED DEVICES, INCLUDING BUT NOT
LIMITED TO; SIGNAGE, STRIPING, FLAGGER LOCATIONS, BARRELS, AND CONES TO MEET THE
REQUIREMENTS OF THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES (LATEST EDITION).
TAPER LENGTHS, DISTANCES BETWEEN TRAFFIC CONTROL MEASURES, AND DIMENSIONS BETWEEN
SIGNS MUST BE SHOWN.
UTILITY PROVIDER LIST:
NAME FACILITY TYPE PHONE
ATLANTA GAS LIGHT CONYERS- AGL109 GAS (404) 387 3164
ATT/ T - ATT02 TELECOMMUNICATION (800) 241 3624
ATT/ T - BSCA TELECOMMUNICATION (305) 409 1542
COMCAST - CMADEK TELECOMMUNICATION (678) 708 7112
DEKALB COUNTY - DCWS01 WATER (404) 731 3562
DEKALB COUNTY - DCWS02 SEWER (404) 731 3562
GEORGIA POWER - GP843 ELECTRIC (404) 506 6539
C002
LEGENDS
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-001GN
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-0 gn
.1
1.
:4
1:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
X X
RAILROAD TRACK
FENCE LINE
GUARD RAIL
RETAINING WALL
STORM SEWER
SANITARY SEWER
FM FORCEMAIN
WATERMAIN
IRR IRRIGATION LINE
G G UNDERGROUND GAS LINE
COM UNDERGROUND COMMUNICATION LINE
F/O F/O UNDERGROUND FIBER OPTIC LINE
UE UE UNDERGROUND ELECTRIC LINE
OU OVERHEAD UTILITY LINE
EDGE OF PAVEMENT / GRAVEL
ROAD CENTERLINE
DITCH CENTERLINE
WET WETLAND BOUNDARY
TREE LINE
CONCRETE PAVEMENT
BITUMINOUS PAVEMENT
GRAVEL SURFACE
BUILDING
CURB AND GUTTER
SANITARY MANHOLE
CLEANOUT
STORM SEWER MANHOLE
STORM SEWER INLET
FLARED END SECTION
CURB STOP
HYDRANT
WATER WELL
WATER VALVE
EB
GV
MB
TP
WV
W
DYH
R R
AUTO SPRINKLER
POST INDICATOR VALVE
WATER METER
SPRINKLER HEAD
IRRIGATION CONTROL VALVE
GAS MARKER
GAS VALVE
COMMUNICATIONS PEDESTAL
TELEPHONE MANHOLE
ELECTRICAL PEDESTAL
ELECTRIC METER
TRANSFORMER
ELECTRIC MANHOLE
SIGN
BOLLARD/POST
UTILITY POLE
ANCHOR CABLE
LIGHT POLE
DECORATIVE LIGHT
STUMP
DECIDUOUS TREE
CONIFEROUS TREE
SHRUB/PERENNIAL PLANT
ANTENNA
BENCH
AIR CONDITIONER
SOIL BORING
MAILBOX
HANDICAP PARKING SPACE
RAILROAD CROSSING SIGNAL
STOP LIGHT
HAND HOLE
XXXXXXXXXXXXXXXXX
ROCK CONSTRUCTION EXIT
SILT FENCE
INLET PROTECTION
BIOLOG [OR DITCH CHECK]
EROSION CONTROL BLANKET
SOD
RIPRAP
SOD
#PARKING COUNT
MINOR CONTOUR 901
MAJOR CONTOUR 900
GRADING LIMITS
CONSTRUCTION LIMITS
SPOT ELEVATION
SURFACE GRADE & FLOW DIRECTION
DRAINTILE
I I
ORNAMENTAL TREE
SEED
ROCK MULCH
GAS METER
WETLAND
TURF REINFORCEMENT MAT
VEGETATED RIPRAP
FLOTATION SILT CURTAIN
TEMPORARY DIVERSION DITCH
HAY BALES
CULVERT PROTECTION
TREE PROTECTION
TEMPORARY SEDIMENT TRAP DISCHARGE
HEAVY DUTY BITUMINOUS PAVEMENT
LIGHT DUTY BITUMINOUS PAVEMENT
X
SURFACE SLOPE (H:V) & FLOW DIRECTION
FM
I IPIPE CASING
WOOD MULCH
3.0:1
1.00%
LOT LINE
EASEMENT LINE
SETBACK LINE
RIGHT OF WAY LINE
SECTION LINE
QUARTER LINE
PROPERTY BOUNDARY
LEGAL / BOUNDARY LEGEND
DESCRIPTIONEXISTING PROPOSED
UTILITY LEGEND
DESCRIPTIONEXISTING PROPOSED
FIRE DEPARTMENT CONNECTION
VEGETATION / LANDSCAPING LEGEND
DESCRIPTIONEXISTING PROPOSED
SITE / MISC. LEGEND
DESCRIPTIONEXISTING PROPOSED
EROSION CONTROL LEGEND
DESCRIPTION PROPOSED
GRADING / TOPOGRAPHY LEGEND
DESCRIPTION PROPOSEDEXISTING
PAVEMENT LEGEND
DESCRIPTIONEXISTING PROPOSED
TIP-OUT CURB AND GUTTER
HEAVY DUTY CONCRETE PAVEMENT
REMOVE EXISTING BUILDING
REMOVE CONCRETE PAVEMENT
CLEAR AND GRUB AREA
SAWCUT & REMOVE CURB AND GUTTER
AT HEADER CURB LOCATION
REMOVE & SALAVGE SIDEWALK PAVERS
REMOVE TREE/SHRUB/STUMP
REMOVE ASPHALT PAVEMENT
SAWCUT PAVEMENT
REMOVALS LEGEND
DESCRIPTION PROPOSED
9XX.XX
ABBREVIATIONS
BV BUTTERFLY VALVE
BW BOTTOM OF WALL (AT GRADE)
BVC BEGIN VERTICAL CURVE
BOT BOTTOM
CB CATCH BASIN
CBMH CATCH BASIN MANHOLE
CO CLEANOUT
CF CUBIC FEET
CFS CUBIC FEET PER SECOND
℄ CENTERLINE
CL CLASS
CMP CORRUGATED METAL PIPE
CY CUBIC YARDS
DIP DUCTILE IRON PIPE
EG EXISTING GRADE
EOF EMERGENCY OVERFLOW
EL ELEVATION
EP EDGE OF PAVEMENT
EVC END VERTICAL CURVE
EX EXISTING
F/F FACE TO FACE
FFE FINISHED FLOOR ELEVATION
FES FLARED END SECTION
FM FORCEMAIN
FNH FRONT NOZZLE OF HYDRANT
FG FINISHED GRADE
FL FLOW LINE
GV GATE VALVE
GPM GALLONS PER MINUTE
HDPE HIGH-DENSITY POLYETHYLENE
HP HIGH POINT
HYD HYDRANT
HWL HIGH WATER LEVEL
INV INVERT
LF LINEAL FEET
LFE LOW FLOOR ELEVATION
LP LOW POINT
LVC LENGTH OF VERTICAL CURVE
OC ON CENTER
OCS OUTLET CONTROL STRUCTURE
MAX MAXIMUM
MH MANHOLE
ME MATCH EXISTING
MIN MINIMUM
NWL NORMAL WATER LEVEL
OFF OFFSET
PC POINT OF CURVATURE
PI POINT OF INTERSECTION
PL PROPERTY LINE
PR PROPOSED
PT POINT OF TANGENCY
PVC POLYVINYL CHLORIDE
PVI POINT OF VERTICAL INTERSECTION
R RADIUS
RCP REINFORCED CONCRETE PIPE
RIM STRUCTURE TOP OF CASTING/GRATE
ROW RIGHT OF WAY
SF SQUARE FEET
SS SANITARY SEWER
SSMH SANITARY SEWER MANHOLE
ST STORM SEWER
STA STATION
STD STANDARD
STMH STORM SEWER MANHOLE
SW SIDEWALK
SY SQUARE YARDS
TC TOP OF CURB
TNH TOP NUT OF HYDRANT
TOE TOE OF DITCH
TOP TOP OF DITCH
TP TOP OF PIPE
TW TOP OF WALL
TYP TYPICAL
VCP VITRIFIED CLAY PIPE
WM WATERMAIN
SEED
REDUCER
75' IMPERVIOUS
SETBACK
▲ CREEK SETBACK
WETLAND LIMITS
CREEK CENTERLINE
WETLAND
WATER
2% MAX 3:1
8'
VARIES
12'
6%
2'6'2'5'
2% MAX 3:1
8'
5' 2'
VARIES
12'
VARIES
TYPICAL SECTION 1
6%
TYPICAL SECTION 2
N.T.SN.T.S
2% MAX 3:1
VARIES
12'
6%
2'5'
TYPICAL SECTION 3
N.T.S
8'
2% MAX 3:1
VARIES
12'
6%
2'5'
TYPICAL SECTION 4
N.T.S
8'
6.5' 7.65'
2% MAX
2:1
8'
VARIES
12'
2%
6'5'
TYPICAL SECTION 5
N.T.S
2% MAX
C200
TYPICAL SECTION
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-200SP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-2 sp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
WM
WV
WV
WV
W W
T
EBX
EBX
EBX
ZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZZ
828 826
822 820
816 814
810 808
8 796
810812 80
81882 082282
4826828
W
ILLO
W
IC
K D R
IVE
(PR
IVATE)
PL
P L
TR
IBU
TAR
Y TO
PO
LE
BR
ID
G E C
R
EEK
XXX
X X
X X
X X
X X
X
XXXX
X X
X
XX
X
X X
XXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
FAIRINGTON ROAD FAIRINGTON ROAD
FAIRINGTON ROAD
C C C C C C C C F F F F F F F F F F F F F F
F
F
C
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
X
XX
X
810820 80680881281481681882
782784786
784786
79079279479
780782784786
-4+45 -4+00 -3+00 -2+00 -1+00 0+00
1+00 2+00
3+00 4+00 4+46
-4+45 -4+00
-5+00 -4+50 -4+00 -3+50 -3+00 -2+50 -2+00 -1+50 -1+00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00
6.
6.
5.
5.
4.
4.
3.
3.
2.
2.
0.
0.
8.
8.
7.
7.
5.
5.
4.
4.
2.
2.
1.
1.
9.
9.
7.
7.
6.
6.
5.
5.
3.
3.
2.
2.
0.
0.
9.
9.
7.
7.
6.
6.
5.
5.
4.
4.
4.
4.
3.
3.
2.
2.
2.
2.
1.
1.
0.
0.
0.
0.
9.
9.
9.
9.
9.
9.
9.
9.
3.5' OBJECT
HEIGHT
3.5' OBJECT
HEIGHT
3.5' OBJECT
HEIGHT
EXISTING
GROUND
EXISTING
GROUND
445 FT LINE OF
SIGHT RIGHT
445 FT LINE OF
SIGHT LEFT
PROPOSED
GRADE
PROPOSED
GRADE
C211
SIGHT DISTANCE PLAN 1
EXHIBIT
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-211-SIGHT DISTANCE2
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-2
-si gh t d ist an ce
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 50 ft.
50 10050
N
SIGHT DISTANCE 1 PROFILE
SCALE: H: 1"=50' V 1"=10'
SIGHT DISTANCE CERTIFICATION
I, THE UNDERSIGNED, HEREBY CERTIFY THE SIGHT DISTANCE FOR THE PROJECT IS
AS SHOWN BELOW. THE REGULATED SPEED LIMIT ON THE APPROACHING
THOROUGHFARE IS 40 MPH. THE DESIGNED SIGHT DISTANCE PROVIDES VISIBILITY OF
445 FEET TO THE LEFT AND 445 FEET TO THE RIGHT. THE SIGHT DISTANCE SHALL BE
MEASURED FROM A POINT OF 15 FEET BEHIND THE EDGE OF PAVEMENT AT AN EYE
LEVEL OF 3.5 FEET AND LOOKING AT AN OBJECT 3.5 FEET ABOVE THE CENTERLINE.
SIGNED _____________________________________________________ DATE 11/07/2024
FAIRINGTON ROAD SPEED LIMIT: 40 MPH
TOTAL LANES: 2
REQUIRED SIGHT DISTANCE LEFT: 445'
PROVIDED SIGHT DISTANCE LEFT: 445'
REQUIRED SIGHT DISTANCE RIGHT: 445'
PROVIDED SIGHT DISTANCE RIGHT: 445'
NOTES:
1. ENTRANCE CONFIGURATION IS EXISTING. ADJUSTMENT
TO THE ROADWAY SHOULDER GRADE ARE PROPOSED IN
THIS PROJECT.
2. EXISTING TOPOGRAPHIC DATA SHOWN IS FROM THE
SURVEY BY KCI.
EBX
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z
Z Z
Z Z
Z Z
Z
ZZZZZZZZZZZZZ
788 792
78478
L.L.
L.L.
GUARD RAIL
PL
TR
IBU
TAR
Y TO
PO
LE
BR
ID
G E C
R
EEK TIBU
R O
N D
R
IVE
(PR
IVATE)
X X
X X
X
XX
XXXXXXXX
XXXXXXX
XX
X X
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
FAIRINGTON ROAD
FAIRINGTON ROAD
CURVE #1
CURVE #2
F
F F F F F F F F
F
F F
C
C
C
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
N 1346769.7328 E 2301742.0242
END PROJECT
STATION 32+75
786788 782784786
792 794782
780782784786
-4+45 -4+00
-3+00
-2+00
-1+00
0+00
1+00
2+00
3+00
4+00 4+45
PROVIDE ADEQUATE INTERSECTION SIGHT DISTANCE.
THERE IS INSUFFICIENT SIGHT DISTANCE DUE TO TREE LIMBS
AND/OR OVERGROWN SHRUBS. CONTRACTOR TO TRIM
OVERHANGING TREE LIMBS TO PROVIDE A MINIMUM OF 10-FEET
OF VERTICAL CLEARANCE ABOVE THE EXISTING GROUND AND
REMOVE OR TRIM SHRUBS WITHIN THE SIGHT TRIANGLE SHOWN.
SHRUBS TO BE LOWER THAN 2-FEET TOTAL HEIGHT.
-5+00 -4+50 -4+00 -3+50 -3+00 -2+50 -2+00 -1+50 -1+00 -0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00
9.
9.
9.
9.
9.
9.
9.
9.
8.
8.
7.
7.
7.
7.
7.
7.
7.
7.
8.
8.
9.
9.
0.
0.
0.
0.
1.
1.
2.
2.
4.
4.
4.
4.
5.
5.
7.
7.
6.
6.
6.
6.
6.
6.
7.
7.
8.
8.
0.
0.
1.
1.
1.
1.
2.
2.
3.
3.
3.
3.
3.5' OBJECT
HEIGHT3.5' OBJECT
HEIGHT
3.5' OBJECT
HEIGHT
EXISTING
GROUND
EXISTING
GROUND
445 FT LINE OF
SIGHT RIGHT
445 FT LINE OF
SIGHT LEFT
PROPOSED
GRADE
PROVIDE ADEQUATE INTERSECTION SIGHT DISTANCE.
THERE IS INSUFFICIENT SIGHT DISTANCE DUE TO TREE
LIMBS AND/OR OVERGROWN SHRUBS. CONTRACTOR
TO TRIM OVERHANGING TREE LIMBS TO PROVIDE A
MINIMUM OF 10-FEET OF VERTICAL CLEARANCE ABOVE
THE EXISTING GROUND AND REMOVE OR TRIM
SHRUBS WITHIN THE SIGHT TRIANGLE SHOWN.
SHRUBS TO BE LOWER THAN 2-FEET TOTAL HEIGHT.
C212
SIGHT DISTANCE PLAN 2
EXHIBIT
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-211-SIGHT DISTANCE2
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-2
-si gh t d ist an ce
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 50 ft.
50 10050
N
SIGHT DISTANCE 2 PROFILE
SCALE: H: 1"=50' V 1"=10'
SIGHT DISTANCE CERTIFICATION
I, THE UNDERSIGNED, HEREBY CERTIFY THE SIGHT DISTANCE FOR THE PROJECT IS
AS SHOWN BELOW. THE REGULATED SPEED LIMIT ON THE APPROACHING
THOROUGHFARE IS 40 MPH. THE DESIGNED SIGHT DISTANCE PROVIDES VISIBILITY OF
445 FEET TO THE LEFT AND 445 FEET TO THE RIGHT. THE SIGHT DISTANCE SHALL BE
MEASURED FROM A POINT OF 15 FEET BEHIND THE EDGE OF PAVEMENT AT AN EYE
LEVEL OF 3.5 FEET AND LOOKING AT AN OBJECT 3.5 FEET ABOVE THE CENTERLINE.
SIGNED _____________________________________________________ DATE 11/07/2024
FAIRINGTON ROAD SPEED LIMIT: 40 MPH
TOTAL LANES: 2
REQUIRED SIGHT DISTANCE LEFT: 445'
PROVIDED SIGHT DISTANCE LEFT: 445'
REQUIRED SIGHT DISTANCE RIGHT: 445'
PROVIDED SIGHT DISTANCE RIGHT: 445'
NOTES:
1. ENTRANCE CONFIGURATION IS EXISTING. ADJUSTMENT
TO THE ROADWAY SHOULDER GRADE ARE PROPOSED IN
THIS PROJECT.
2. EXISTING TOPOGRAPHIC DATA SHOWN IS FROM THE
SURVEY BY KCI.
NOTE: SEE RIGHT-OF-WAY CLEARING REQUIREMENTS ABOVE.
DEL/5/8" REBAR W/ CAP
806.95
DEL/5/8" REBAR W/ CAP
805.08
DEL/60D NAIL
794.26DEL/60D NAIL
786.67DEL/60D NAIL
793.17
DEL/60D NAIL
810.01
DEL/60D NAIL
828.07
DEL/5/8" REBAR W/ CAP
832.27
DEL/5/8" REBAR W/ CAP
836.12
WM
WV
WV
WV
W W
T
GUARD RAIL
W
ILLO
W
IC
K D R
IVE
(PR
IVATE)
PL
P L
APPROXIMATE R/W OF I-20
TR
IBU
TAR
Y TO
PO
LE
BR
ID
G E C
R
EEK TIBU
R O
N D
R
IVE
(PR
IVATE)
A1A2A3
X
X
X X
XXXXX
XXX
X
X X
X
XX
X
X X
XX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
FAIRINGTON ROAD FAIRINGTON ROAD
FAIRINGTON ROAD FAIRINGTON ROAD
FAIRINGTON ROAD
CURVE #1
CURVE #2
F F F F C C C C F F F F F F F F F F
C
F
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
X
MA
TC
H
LIN
E
ST
AT
IO
N
+5
MA
TC
H
LIN
E
ST
AT
IO
N
+0
MA
TC
H
LIN
E
ST
AT
IO
N
+0
MA
TC
H
LIN
E
ST
AT
IO
N
+0
C301 C302 C303 C304 C305 N 1346930.9341 E 2299479.4787
N 1346769.7328 E 2301742.0242
END PROJECT
BEGIN PROJECT
S 89° 39' 19.02" E
S 66° 20' 29.93" E
S 75° 34' 06.69" E
CONTROL POINT
TYPICAL
C300
CONSTRUCTION
LAYOUT
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-300GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 100 ft.
100 200100
N
CURVE #1
PI STA= 28+04.08
N= 1346920.0801 E= 2301283.5280
DELTA= 14° 05' 12.33"
DEG=5° 02' 08.9"
T= 140.58 L= 279.73 R= 1137.77 e= EXIST
CURVE # 2
PI STA= 30+91.26
N= 1346848.1550 E=2301563.0201
DELTA= 09° 13' 36.77"
DEG= 4° 15' 56.6"
T= 108.81 L= 217.15 R= 1348.44 e= EXIST
832.27
L.L.
L.L.
L.L.
L.L.
APPROXIMATE R/W OF I-20
FAIRINGTON ROAD
F F F F F F F F F F F F F F F F F F F F F F
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
8' G
R
AS
S
ST
R
IP
5' C
O N
C R
ET
E
SI
D
EW
AL
K
N 1346930.9341 E 2299479.4787
PROPOSED
5' CONCRETE
SIDEWALK
CONTRACTOR TO
TIE INTO EXISTING
SIDEWALK.
CONTRACTOR TO
TIE INTO EXISTING
CURB AND GUTTER
BEGIN PROJECT
STATION 10+00
EXISTING R/W LINE
EXISTING EDGE OF
PAVEMENT
CONSTRUCTION
CENTER LINE
TAPER SIDEWALK
0' TO 5'
EXISTING
EDGE OF PAVEMENT
(TYP.)
RESET TEMPORARY
CONSTRUCTION
COORDINATE WITH
OWNER.CONTROL POINT
(TYP)
LIMIT OF
CONSTRUCTION
LIMIT OF
CONSTRUCTION
C301
MAINLINE PLAN
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-301GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 20 ft.
20 4020
N
MA
TC
H
LIN
E
ST
AT
IO
N
+5 0 S
EE
S
HE
ET
C
DEL/60D NAIL
810.01DEL/60D NAIL
828.07
T
828 826
822 820
816 814
810812814
81882 082282
4826828
P L
A3
FAIRINGTON ROAD
C C
C C C C C C C C C C C C C C C C C C C C
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
8' G
R
AS
S
ST
R
IP
5' C
O N
C R
ET
E
SI
D
EW
AL
K
S 89° 39' 19.02" E
EXISTING EDGE OF
PAVEMENT
CONSTRUCTION
CENTER LINE
PROPOSED 5'
CONCRETE
SIDEWALK
EXISTING
EDGE OF PAVEMENT
(TYP.)
ADJUST BOX
TO GRADE
TEMPORARY
CONSTRUCTION
SIGN COORDINATE
WITH OWNER.
EX. FH EXISTING FENCE
TO REMIAN
CONTROL POINT
(TYP)
80881281481681882
LIMIT OF
CONSTRUCTIONDO NOT
DISTURB
EX. COMM
STRUCTURE
C302
MAINLINE PLAN
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-301GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 20 ft.
20 4020
N
MA
TC
H
LIN
E
ST
AT
IO
N
+5 0 S
EE
S
HE
ET
C
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
793.17
DEL/60D NAIL
810.01
WM
WV
WV
WV
W W
EBX
EBX
8 796
W
ILLO
W
IC
K D R
IVE
(PR
IVATE)
A1 A2
A3
XXXXXXXX
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XX
X
XX
XXXXXXXXXX
X X
X X
X X
X X
XXXX
X
X X
X X
X
XXXX
XXXXXXXXXXXX
FAIRINGTON ROAD
F F F F F F F F F F F F F F F F F F
F
F F
F F
C C
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
X X
X X
XXXXX
X
X X
8' G
R
AS
S
ST
R
IP
5' C
O N
C R
ET
E
SI
D
EW
AL
K
PROPOSED TYPE 2
6"X30" CONCRETE
CURB AND GUTTER
MATCH EXISTING
CURB AND GUTTER
TYPE D
HANDICAP RAMP
(TYP)
PROPOSED
CROSSWALK STRIPING
SEE GDOT DETAIL T11A
(TYP)
EXISTING EDGE OF
PAVEMENT
PROPOSED
5' CONCRETE
SIDEWALK
CONSTRUCTION
CENTER LINEEX.
BUS STOP SIGN
PROP. STORM LINE
PROP. JUNCTION
BOX
RECONSTRUCT
TO JB
PROVIDE 1011 TOP
PROPOSED TYPE 2
6"X30" CONCRETE
CURB AND GUTTER
EXISTING
EDGE OF PAVEMENT
(TYP.)
PROPOSED
EDGE OF PAVEMENT
(TYP.)
DO NOT
DISTURB BOX
SAW CUT AND REMOVE
EXISTING (582.96 SF) OF
ASPHALT
SAW CUT AND REMOVE
EXISTING (433.68SF) OF
ASPHALT
PROP.
" STOP"
SIGN R1-1 36"X36"
REMOVE AND REPLACE
EXISTING CURB & GUTTER
REMOVE AND REPLACE
EXISTING CURB & GUTTER
SAW CUT AND REMOVE
31LF OF EXISTING
CURB & GUTTER
AND INSTALL NEW ASPHALT
PROP.
+/- 110 SF ASPHALT
PAVING
SAW CUT AND
REMOVE EXISTING
CURB
MATCH EXISTING
CURB AND GUTTER
ADJUST WV
TO GRADE
EXISTING
FENCE TO
REMAIN
TEMPORARY
CONSTRUCTI0N SIGN
COORDINATE WITH
OWNER.
CONTROL POINT
(TYP)
GUARDRAIL
TERMINAL TYPE 12A
806808 790
LIMIT OF
CONSTRUCTION
CONTRACTOR
TO CLEAR
DEBRIS AROUND
THE EX. PIPE.
6'X14' CONC. PAD
FOR FUTURE
MARTA BUS
SHELTER
8'X8'
CONC.PAD
8'X10' CONC.PAD
6'
SEE MARTA NOTES.
SEE TYPICAL SECTION #5
FOR MARTA BUS PAD
CONSTRUCTION.
SEE SHEET C505 FOR
MARTA DETAILS.
18'
R
' R 35'
PROPOSED
5" WHITE EDGE LINE.
(TYP)
PROPOSED
5" WHITE EDGE LINE.
(TYP)
PROPOSED 6"X30"
CONCRETE
CURB AND
GUTTER
R1'
CURB & GUTTER
TRANSITION BACK TO
GRADE SEE DETAIL (TYP.)
PROPOSED
24" WHITE STOP BAR
(TYP.)
C303
MAINLINE PLAN
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-301GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 20 ft.
20 4020
N
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
MARTA NOTES
1. CONTRACTOR TO CONTACT MARTA TO COORDINATE
CONSTRUCTION AND RESET OF THE SIGNS.
2. CONTRACTOR TO CONTACT MARTA AT LEAST THREE
WEEKS IN ADVANCE BEFORE COMMENCEMENT OF
CONSTRUCTION.
3. MARTA CONTACT: CORENTIN AUGUIN
EMAIL : CAUGUIN@ITSMARTA.COM
T:(404)848-4117
786.67
EBX
78478
P L
TR
IBU
TAR
Y TO
PO
LE
BR
ID
G E C
R
EEK
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
FAIRINGTON ROAD CURVE #1
F F F F F F F F F F F F F F F F F
F F F F F F F F F F F F F F
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
8' G
R
AS
S
ST
R
IP
5' C
O N
C R
ET
E
SI
D
EW
AL
K
R
.7
7'
PROPOSED
5' CONCRETE
SIDEWALK
EXISTING EDGE OF
PAVEMENT
CONSTRUCTION
CENTER LINE
6'X14' CONC. PAD
MARTA SHELTER
EXISTING
EDGE OF PAVEMENT
(TYP.)
EXISTING
EDGE OF PAVEMENT
(TYP.)
ADJUST BOX
TO GRADE
REMOVE AND
REPLACE EXISTING
GUARDRAIL
PROPOSED
GUARDRAIL
BEGIN GUARDRAIL
STATION 23+13
END GUARDRAIL
STATION 27+48
GUARDRAIL
TERMINAL TYPE 12A
792782
25' STREAM
BUFFER
END HANDRAIL
STATION: 25+80
START HANDRAIL
STATION: 25+00
LIMIT OF
CONSTRUCTION
LIMIT OF
CONSTRUCTION
RAISE
EX. HEADWALL 1FT.
SEE DETAIL 9031L
DOUBLE 9' x7'
CULVERT
SEE MARTA NOTES.
SEE TYPICAL SECTION #5
FOR MARTA BUS
PAD CONSTRUCTION.
SEE SHEET C505 FOR
MARTA DETAIL.
C304
MAINLINE PLAN
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-301GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 20 ft.
20 4020
N
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
805.08
DEL/60D NAIL
794.26
788 792
L.L.
L.L.
GUARD RAIL
TIBU
R
O N
D R
IVE
(PR
IVATE)
X X
X X
X X
X X
X X
X X
X X
XX
XX
XXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXX
XXX
X X
X
XXX
X X
FAIRINGTON ROAD
CURVE #2
F
F
F
F
F F F F F
F F
F F
C
C
C
C
C
C
C
C
C
F
F
F
(40 MPH STATE ROUTE 402 I-20 ADDITIONAL R/W)
8' G
RA
SS
ST
RI
P
5' C
O
NC
RE
TE
SI
DE
W
AL
K N 1346769.7328 E 2301742.0242
S 66° 20' 29.93" E
S 75° 34' 06.69" E
R
.4
4'
R
.7
7'
MATCH EXISTING
CURB AND GUTTER
TYPE D
HANDICAP RAMP
(TYP)
PROP. "STOP"
SIGN R1-1
36"X36"
PROPOSED
CROSSWALK STRIPING
SEE GDOT DETAIL T11A
(TYP)
EXISTING EDGE OF
PAVEMENT
CONSTRUCTION
CENTER LINE
6'X14' CONC. PAD
FOR FUTURE
MARTA SHELTER
RELOCATE EX.
BUS STOP SIGN
END PROJECT
STATION 32+75
8'X8'
CONC.PAD
PROPOSED 6"X30" CONCRETE
CURB AND GUTTER
PROPOSED
EDGE OF PAVEMENT
(TYP.)
EXISTING
EDGE OF PAVEMENT
(TYP.)
SAW CUT AND REMOVE
EXISTING (529.87SF) OF
ASPHALT
SAW CUT AND REMOVE
EXISTING (390.95 SF) OF
ASPHALT
REMOVE AND REPLACE
EXISTING CURB & GUTTER
REMOVE AND REPLACE
EXISTING CURB & GUTTER
GUARDRAIL
TERMINAL TYPE 12A
DO NOT DISTURB
EXISTING
MONUMENT SIGN
DO NOT
DISTURB
COMMUNICATION
BOX
792 794
LIMIT OF
CONSTRUCTION
TEMPORARY
CONSTRUCTION
SIGN COORDINATE
WITH OWNER.
SAW CUT AND REMOVE
EXISTING (527SF) OF
ASPHALT
R1
6.
R
.4
4'
8'X10'
CONC.PAD
6'
SEE MARTA NOTES.
SEE TYPICAL SECTION #5
FOR MARTA BUS PAD CONSTRUCTION.
SEE SHEET C505 FOR MARTA DETAIL.
SEE MARTA NOTES.
SEE TYPICAL SECTION #5
FOR MARTA BUS
PAD CONSTRUCTION.
SEE SHEET C505 FOR
MARTA DETAIL.
18'
R
.7
7'
CURB & GUTTER
TRANSITION BACK TO
GRADE SEE DETAIL (TYP.)
CURB & GUTTER
TRANSITION BACK TO
GRADE SEE DETAIL (TYP.)
PROPOSED
5" WHITE EDGE LINE.
(TYP)
PROPOSED
5" WHITE EDGE LINE.
(TYP)
R35'
R30'
PROPOSED
5" WHITE EDGE LINE.
(TYP)
PROVIDE ADEQUATE INTERSECTION SIGHT DISTANCE.
THERE IS INSUFFICIENT SIGHT DISTANCE DUE TO TREE
LIMBS AND/OR OVERGROWN SHRUBS. CONTRACTOR
TO TRIM OVERHANGING TREE LIMBS TO PROVIDE A
MINIMUM OF 10-FEET OF VERTICAL CLEARANCE ABOVE
THE EXISTING GROUND AND REMOVE OR TRIM SHRUBS
WITHIN THE SIGHT TRIANGLE SHOWN.
SHRUBS TO BE LOWER THAN 2-FEET TOTAL HEIGHT.
SEE SHEET C211 & C212
PROVIDE ADEQUATE INTERSECTION SIGHT DISTANCE.
THERE IS INSUFFICIENT SIGHT DISTANCE DUE TO TREE
LIMBS AND/OR OVERGROWN SHRUBS. CONTRACTOR
TO TRIM OVERHANGING TREE LIMBS TO PROVIDE A
MINIMUM OF 10-FEET OF VERTICAL CLEARANCE ABOVE
THE EXISTING GROUND AND REMOVE OR TRIM SHRUBS
WITHIN THE SIGHT TRIANGLE SHOWN.
SHRUBS TO BE LOWER THAN 2-FEET TOTAL HEIGHT.
SEE SHEET C211 & C212
C305
MAINLINE PLAN
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-301GP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 gp
.1
1.
:4
2:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
PROFESSIONAL
REENIGNE
( IN FEET )
GRAPHIC SCALE
1 inch = 20 ft.
20 4020
N
MA
TC
H
LIN
E
ST
AT
IO
N
+0 0 S
EE
S
HE
ET
C
MARTA NOTES
1. CONTRACTOR TO CONTACT MARTA TO COORDINATE
CONSTRUCTION AND RESET OF THE SIGNS.
2. CONTRACTOR TO CONTACT MARTA AT LEAST THREE WEEKS
IN ADVANCE BEFORE COMMENCEMENT OF CONSTRUCTION.
3. MARTA CONTACT: CORENTIN AUGUIN
EMAIL : CAUGUIN@ITSMARTA.COM
T:(404)848-4117
-0+20 0+00 0+20 0+40 0+60 0+80 1+00 1+20 1+40 1+60 1+80 2+00
6.
7.
8.
9.
9.
0.
1.
1.
3.
3.
3.
4.
4.
5.
5.
6.
6.
7.
7.
7.
7.
6.
A3 GDOT 1120 FES (Concrete)
RIM=807.21
INV OUT=805.50
DEPTH=???
8 LF OF RCP @ 2.57%
MAX COVER: 0.80
MIN COVER: -0.20
A2
AD
JU
ST
T
O G
R
AD
E Ju nc tio n Bo x R
IM
=8
.8
IN
V
IN
=8
.3
IN
V
O U
T=
5.
D
EP
TH
=2
.8A1
AD
JU
ST
T
O G
R
AD
E
PR
O
VI
D E
N
EW
L
ID
Ju nc tio n
Bo x
R
IM
=8
.3
IN
V
IN
=8
.6
(A
2)
IN
V O
U T=
0.
D
EP
TH
=3 .7
EXISTING GROUND
PROPOSED GRADE
COMM
COMM
COMM
C311
STORM DRAIN
PROFILES
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-311DP
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 dp
.1
1.
:4
6:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
10+00.00
0 10 20 30 40 50 60 700-10
10+50.00
0 10 20 30 40 50 60 700-10
11+00.00
0 10 20 30 40 50 60 700-10
11+50.00
0 10 20 30 40 50 60 700-10
12+00.00
0 10 20 30 40 50 60 700-10
12+50.00
0 10 20 30 40 50 60 700-10
13+00.00
0 10 20 30 40 50 60 700-10
13+50.00
0 10 20 30 40 50 60 700-10
14+00.00
0 10 20 30 40 50 60 700-10
C321
CROSS SECTIONS
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-321PR
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 pr
.1
1.
:4
9:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
14+50.00
0 10 20 30 40 50 60 700-10
15+00.00
0 10 20 30 40 50 60 700-10
15+50.00
0 10 20 30 40 50 60 700-10
16+00.00
0 10 20 30 40 50 60 700-10
16+50.00
0 10 20 30 40 50 60 700-10
17+00.00
0 10 20 30 40 50 60 700-10
17+50.00
0 10 20 30 40 50 60 700-10
18+00.00
0 10 20 30 40 50 60 700-10
18+50.00
0 10 20 30 40 50 60 700-10
C322
CROSS SECTIONS
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-321PR
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_ file s\
2c
-3 pr
.1
1.
:4
9:
P M
Tel:
www.stantec.com
Stantec Consulting Services Inc.
229 PEACHTREE ST NE #1900
ATLANTA, GA 30303
(770) 493-0450
A
B
C
D
1 2 3 4 5
CITY OF STONECREST
FAIRINGTON ROAD SIDEWALK
CITY OF STONECREST, GA
234300052
2024.02.14
DEVELOPER / CLIENT: CITY OF STONECREST
CONTACT: HARI KARIKARAN
24 HOUR CONTACT:HARI KARIKARAN
PHONE: (770) 224-0200
EMAIL: HKARIKARAN@STONECRESTGA.GOV
AS SHOWN
DMDM WN
R
EG I STEREDGEORG I A
NO. 32190
K
EV IN WAYNE CLARK
19+00.00
0 10 20 30 40 50 60 700-10
19+50.00
0 10 20 30 40 50 60 700-10
20+00.00
0 10 20 30 40 50 60 700-10
20+50.00
0 10 20 30 40 50 60 700-10
21+00.00
0 10 20 30 40 50 60 700-10
21+50.00
0 10 20 30 40 50 60 700-10
22+00.00
0 10 20 30 40 50 60 700-10
22+50.00
0 10 20 30 40 50 60 700-10
23+00.00
0 10 20 30 40 50 60 700-10
C323
CROSS SECTIONS
Project No. Scale
Revision Drawing No.Sheet
Title
Client/Project
Client/Project Logo
Permit/Seal
Issued
Revision
Consultant
Copyright Reserved
By Appd YYYY.MM.DD
By Appd YYYY.MM.DD
Dsgn. Chkd. YYYY.MM.DDDwn.
The Contractor shall verify and be responsible for all dimensions. DO NOT scale the drawing
- any errors or omissions shall be reported to Stantec without delay.
The Copyrights to all designs and drawings are the property of Stantec. Reproduction or use for any purpose other than that authorized by Stantec is forbidden.
File Name: 00052C-321PR
ORIGINAL SHEET - ARCH D
us
-p pf ss
\s ha re d_ pr oj ec ts\
2\ ci vil \d ra w in g\ sh ee t_…
This is the start of the file's text. The full file is on GovTribe.