Attachment C - Flagpole Detail Drawing.pdf
PDF 1 MB Posted
- Attached to
- Snake River National Cemetery Flagpole Repair-
- Solicitation number
- 36C78625Q0110
About this file
This engineering drawing set details site amenity specifications for the Twin Falls National Veterans Burial Ground in Buhl, Idaho, focusing on three primary components: Gravesite Locator, Gravesite Locator Box, and Grave Site Grid Monument. The technical drawings provide precise construction details including materials (stainless steel, granite, forged aluminum), dimensional specifications, installation requirements, and technical notes for each element. Key specifications include a 4,000 PSI reinforced concrete foundation, 16 GA stainless steel grave locator box with welded corners, a 3½" domed-top forged aluminum monument marker with field-incised cross-hairs, and specific installation guidelines such as setting the monument ½" above finish grade and ensuring precise grid alignment within ±0.005'.
The document is part of the National Cemetery Administration's project documentation, created on 04-15-19 with project number 941CM3001, and includes detailed technical drawings with specific construction requirements for gravesite identification and marking infrastructure. Additional details include requirements for concrete work, surface finishes, dowel placement, epoxy grouting, and installation notes emphasizing precise positioning and durability of the gravesite grid monuments and associated infrastructure.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| IMG_3346.jpg | JPG image | |
| RFIs-AMEND 1.docx | DOCX document | |
| AMEND 1.docx | DOCX document | |
| IMG_3347.jpg | JPG image | |
| IMG_3348.jpg | JPG image | |
| Attachment B - Section 10 75 00 Flagpoles Specification.pdf | ||
| SOW.docx | DOCX document | |
| Attachment A - Pictures of damage to flagpoles.pdf | ||
| 36C78625Q0110 RFQ-Snake River Flagpole Repair.docx | DOCX document | |
| wage determination.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
2'-6"
2"
4" 1'-6"
2'-0" X 2'-6" BEVELED TOP
SECURE TOP TO PEDESTAL
BASE WITH EPOXY
" X
" STAINLESS STEEL
DOWELS @ 12" O.C. EPOXY
DOWELS AND GRANITE SLAB
END JOINTS TO PROVIDE A
MONOLITHIC PEDESTAL.
GRAVE
LOCATOR
2'-6"
2"
2"
2'-2"
2'-0"
7 8
1'-8"
BEVELED GRANITE TOP.
EPOXY GROUT TO
PEDESTAL BASE
S.S. GRAVE LOCATOR BOX.
4" THICK GRANITE SLAB, TYP.
" X 4" STAINLESS STEEL DOWELS. (4)
REQUIRED. EPOXY GROUT DOWELS
INTO CONCRETE SLAB AND GRANITE
PEDESTAL.
FINISH GRADE (CONCRETE
PAVEMENT), TYP.
CONTINUOUS
DRIP EDGE
SLOT
S.S. TAMPER-PROOF
SCREW (3) REQUIRED -
ONE EACH SIDE AND
REAR PANEL. ANCHOR
INTO GRANITE
PEDESTAL BASE
A'
A
S.S. ANCHOR PINS/BOLTS
PROVIDE SHOP DRAWINGS,
TYP.
LAYOUT POINT, SEE
CS401 FOR LOCATION
C
L
C
L
4,000 PSI REINFORCED CONC.
FOUNDATION W/BROOM FINISH TOP
LOW PERMEABLE
FILL; SEE
GEOTRECH
REPORT FOR
REQUIREMENTS.
#5 BARS VERTICAL 12"
O.C. EACH FACE, TYP.
#5 BARS VERTICAL 12"
O.C. EACH WAY, TYP.
#4 TIES @ 8" O.C., TYP.
1'-5
1'-5
"STAINLESS STEEL
CONTINUOUS HINGE
GRAVE
LOCATOR
GRAVE LOCATOR BOX TO BE FABRICATED FORM 16 GA
STAINLESS STEEL. GRAVE LOCATOR BOX LID SHALL BE
FABRICATED FROM 12 GA STAINLESS STEEL. ALL CORNERS
SHALL BE WELDED. CONTINUOUS HINGE SHALL BE STAINLESS
STEEL. SPOT WELD HINGE TO BOX AND LID. ALL DISCOLORATION
FROM WELDS SHALL BE REMOVED AND STEEL PLATES SHALL BE
POLISHED TO PROVIDE A SMOOTH FINISH FREE OF
IMPERFECTIONS. SECURE THE GRAVE LOCATOR BOX TO THE
GRANITE PEDESTAL WITH TAMPER-PROOF SCREWS.
ENGRAVE OR ATTACH
PERMANENT WHITE
REFLECTIVE SIGN LETTERS
ON GRAVE LOCATOR BOX LID.
" DIA. HOLE. PROVIDE ON
BOTH SIDE PANELS AND
ONE ON THE REAR PANEL
OF THE BOX.
STAINLESS STEEL
CONTINUOUS HINGE
1'-3
1'-3
3"
7 8
7 8
D E
P T
H
T
O
F
R O
S T
SET TOP OF
MONUMENT 1/2"
ABOVE
FINISH
GRADE
MONUMENT MARKER (PROTECT
VISIBLE SURFACES DURING
PLACEMENT INTO CONCRETE)
FORGED ALUMINUM DOMED-TOP MONUMENT
MARKER WITH 3/4" DIAMETER SPLIT STYLE
STEM AND INTEGRAL LOCATION MAGNET
IMBEDED
SMOOTH-TROWEL FINISH TOP
SURFACE, ENSURING POSITIVE
DRAINAGE
8" CONC. CYLINDER W/3,500 PSI
CONCRETE @ 28 DAYS
GAP AROUND CYLINDER & SURROUNDING
EARTH SHALL BE FILLED W/CONCRETE OR
REDI-CRETE (WETTED AFTER PLACEMENT) TO
WITHIN 4" OF FINISH GRADE
COMPACTED APPROVED FILL OR
NATIVE EARTH
NOTES:
1. ALL LAWNS WITHIN THE BURIAL SECTIONS
SHALL BE INSTALLED AND ACCEPTED PRIOR
TO MONUMENT-BASE PLACEMENT; ALL LAWNS
DAMAGED DURING INSTALLATION SHALL BE
REPAIRED AT CONTRACTOR'S EXPENSE
2. AT TO CONTRACTOR'S OPTION, GRAVE SITE
GRID MONUMENTS MAY BE PROVIDED AS
PRECAST UNITS. PROVIDE SHOP DRAWINGS
AND METHOD OF INSTALLATION FOR
APPROVAL.
3. FINISH GRADE IS TOP OF TOPSOIL.
4. GRID MONUMENT CROSS HAIR TO BE INCISED
TO A MINIMUM DEPTH OF 1/64" SO AS TO BE
CLEARLY VISIBLE AND PERMANENTLY
LEGIBLE.
"Ø FORGED ALUMINUM
DOMED-TOP MONUMENT
MARKER
FIELD INCISED HAIRS ON CAP;
1/64" MIN DEPTH. CROSS-HAIRS
SHALL BE PARALLEL AND
PERPENDICULAR TO THE
GRAVESITE GRIDLINES &
PRECISE TO ±0.005'
REQUIRED TEXT ENGRAVED ON
CAP
CROSS HAIRS
MUST FALL WITHIN
3/4" OF THE
CENTER OF THE
MARKER OR THE
ENTIRE
MONUMENT MUST
BE MOVED
PLAN
G R
A V
E
S
I T E G R I D MO NU
M E
N T
FACTORY INCISED
1.5" Ø CIRCLE
1" MIN.
MONUMENT MARKER
CONCRETE BASE
EDGE OF MONUMENT MARKER SHALL
BE NO CLOSER THAN 1" TO OUTSIDE
EDGE OF CONCRETE
MONUMENT MARKER (PROTECT
G
M
I N
H
M
I N
"F"
MIN. DIA.
"D"
"E"
"A" MIN. DIA.
"C"
"B"
SEE STRUCTURAL
NOTES:
THE UNDEREXPOSED SURFACE OF THE FLAGPOLE (BELOW GRADE)
SHALL RECEIVE A HEAVY COAT OF BLACK ASPHALTIC PAINT INSIDE
AND OUT BEFORE SHIPMENT
POLE MATERIAL:
FLAGPOLE SHALL BE MADE FROM 6063-T6 ALLOY SEAMLESS COLD
DRAWN EXTRUDED ALUMINUM TUBING
POLE FINISH: SEE SPECIFICATIONS
60' HT. POLE FLAG SIZE BASIS OF DESIGN 12'X18'. U.S. FLAG
GOVERNMENT PROVIDED.
E X
P O
S E
D
H
E I G
H T
GOLD ANODIZED ALUMINUM FINIAL BALL (SEE SPECS.)
CONE STYLE, REVOLVING, INTERNAL HALYARD TRUCK (SEE SPECS)
FLAG (N.I.C.) - PROVIDED BY OWNER, INSTALLED BY CONTRACTOR
COVERED COUNTERWEIGHT & NYLON BEADED RETAINER (SEE SPECS);
LOOP WITH NICKEL PLATED SNAP HOOKS
FIELD SPLICE: SEE SPECIFICATIONS FOR REQUIREMENTS IF APPLICABLE
(NOT ALLOWED FOR POLES LESS THAN OR EQUAL TO 35')
WINCH
ASSEMBLY
E.J.
FINISH
GRADE
FLAGPOLE (SEE SPECIFICATIONS)
SILICONE SEALANT AROUND
ALUMINUM FLASHING COLLAR
WATERPROOF CEMENT SEALANT 2" MIN. DEPTH
5" CONC. WALK PVMT.
4 HARDWOOD WEDGES (TEMP.)
PACKED DRY SAND
1/16" (16 GA.) GALV. CORRUG. STEEL SLEEVE EXTENDED UP
TO FINISH GRADE
3500 psi MIN. CONCRETE
4 STEEL WEDGES WELDED TO STEEL PLATE
WELDED STEEL BASE PLATE
6" SQUARE STEEL SUPPORT PLATE WELDED TO SPIKE
3/4" Ø x (MIN. 6" BELOW CONC.) ATTACH LIGHTENING KIT TO ROD
WELDED TO PLATES
LIGHTENING KIT COPPER WIRE (SEE SPECIFICATIONS)
SELECT
GRANULAR
FILL TO
EXISTING
SUBGRADE
1'-0"
MIN.,
TYP.
ENSURE POSITIVE DRAINAGE AWAY FROM BASE, TYP.
3"X3"
POST, TYP.
1"X1"
PICKET, TYP.
C
L
"X1
RAIL, TYP.
PROVIDE 1/2" RADIUS & SMOOTH
TROWEL FINISH ACROSS TOP OF
FOOTING (TYP.)
MIN. DIA. 3X
POST WIDTH
POND LINER W/ ANCHOR
TRENCH; SEE B1/LI506
2'-WIDE SWATH OF LANDSCAPE FABRIC (TYP.); PROVIDE
WOVEN NEEDLE-PUNCHED POLYPROPYLENE FABRIC
WEIGHING 4.8 OZ./SY AND A FLOW RATE OF 90 GAL./MIN./SF
FENCE POST FOOTING
(BEYOND)
FINISH GRADE
(TYP.); TURF
T
Y P
T
Y P
T
Y P
T
Y P
6" ANDESITE COBBLE
ROAD
SIDE
POND
SIDE
B2
CI530
C
A
ATIONAL
EMETERY
DMINISTRATION
N
Revisions Date
Drawing Title
Approved:
Approved:
Project Title
Building Number
Checked Drawn
Location
Date
Project No.
DRAWING NO.
Dwg.
Of
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A B
C D
E F
A B
C D
E F
BUHL, IDAHO
TWIN FALLS
NATIONAL VETERANS
BURIAL GROUND
04-15-19
941CM3001
Seabee Construction, LLC
2213 Cochran Drive
Gresham, OR 97080
(503) 512-7647
G&C Fab-Con, LLC
5 Foster Lane, Bldg. A
Flemington, NJ 08822
(908) 782-0526
The LA Group
40 Long Alley
Saratoga Springs, NY 12866
(518) 587-8100
04-15-19
1" = 1'-0"
GRAVESITE LOCATOR
D3
1'0 6"3"
SITE AMENITY DETAILS 2
CI504
KFSDLM
1-1/2" = 1'-0"
GRAVESITE LOCATOR BOX
D7
8"0 4"2"
1" = 1'-0"
GRAVE SITE GRID MONUMENT
F3
1'0 6"3"
1" = 1'-0"
FLAG POLE
E1
1'0 6"3"
REISSUED FOR CONSTRUCTION 7/31/19
ISSUED FOR CONSTRUCTION 6/26/19
Scale: NTS
6' ORNAMENTAL PICKET FENCE FOOTING AT IRRIGATION POND
B7