This document includes a federal contract opportunity solicitation and related waste profile attachment. The solicitation is for a turnkey operation to demolish an existing VOC abatement system, relocate a building gas line, and modify ventilation systems for four paint booths at building 350 to function as standalone systems. The scope of work includes ductwork, supply and exhaust stacks, booth interlocks, control panels, sprinklers, no loss stacks, emergency stops, paint booth controls integrated with ventilation, sprinklers and alarms. The contractor must provide all labor and materials to yield a complete, usable and compliant system. The waste profile describes filters from the VOC control device as a solid RCRA hazardous waste in bulk or containerized quantities for disposal. The generator is identified as Letterkenny Army Depot.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Waste Profile Number: VOCFILTERS Reference Sample ID: 1521 & 1589 NSN: 9999

Profile Sheet 21-DEC-20 18:28:13 Page 1

SENSITIVE BUT UNCLASSIFIED

FILTERS, VOC CONTROL DEVICE

N

Y

N

N

HW

DRUM/BULK

Name of Waste:

Process Generating Waste:

Projected Annual Volume:

Mode of Collection:

Is this waste a dioxin listed waste as defined in 40 CFR 261.31?

Is this waste restricted from land disposal (40 CFR 268)?

Does the waste meet applicable treatment standards?

Has exemption been granted?

Waste Type:

Process Type:

Waste Stream Number:

Units:

Solid NPhysical State: Treatment Group:

N NIgnitable: Corrosive:

Flash Point (F): pH:

Y

NCorrodes Steel:

Toxicity Characteristics:

NReactive:

NWater Reactive:

N

N

Cyanide Reactive:

Sulfide Reactive:

N NN

Material Characteristics

Color:

Total Solids:

Density:

Single Phase:

BTU/LB::

Bi Layered:

Ash Content::

Multi Layered:

Chemical Composition

Copper:

Zinc:

Phenolics:

Volatile Organics:

Nickel:

Chromium-Hex:

Total Halogen:

Pesticide/PCBs:

Shipping Information

RCRA Characteristics

Other Characteristics: N

Proper Shipping Name: RQ, HAZARDOUS WASTE, SOLID, N.O.S (D006) Hazard Class: 9 UN or NA Number: NA 3077 Package Group:

ERG Guide Number: Edition Year: 2008171

DOT Hazardous Material?

Method of Shipment:

Y

BULK

Generator Name : LETTERKENNY ARMY DEPOT US EPA ID :

State ID :

PA6213820503

LETTERKENNY ARMY DEPOT

CHAMBERSBURG , PA 17201-4150

Technical Contact: DOUGLAS A WARNOCK Phone:

Start Date: End Date: 26-SEP-2011 26-SEP-2012

Process Name:

State Waste Code:

High TOC (> 10%):

Low TOC (< 10%):

N

N

Other Comments:

RCRA Requirement:

Additional RCRA Requirement:

UNAG OR UN11G BOX OR ROLLOFF IF BULKED

UHC: CHROMIUM

Other:

Equipment Number:

Description:

Units:

Is this a reoccurring waste profile? Y

Sub Haz 1: Sub Haz 2:

717-267-9022

VOC Abatement System Removal 350 ATTACHMENT B 30 December 2020

Profile Sheet 21-DEC-20 18:28:13 Page 2

SENSITIVE BUT UNCLASSIFIED

Additional Description:

CERCLA Reportable Quantity (RQ): DEMIL Code:

Default Contract Line Items

SP4500-12-D-0011

SP4500-12-D-0011

CONTAINERIZED SOLIDS

BULK SOLIDS [SEE C.3.9]

9407LK

Contract Number CLIN Description

Default Handling Costs

Handling Cost Code Description

EPA Waste Codes

D006 Cadmium

EPA Code Description Range High

State Codes

State Waste Code Description Restricted

Material Composition

Component Component Name Concentration (If < 1%) Lower Range (%)

Authorized Waste Collection Sites

0350-5P200 DRMOBLDG 350

Collection Site Description Decision Code

Biennial Information

G21

W310

NIs this waste mixed with nuclear source, special nuclear, or by-product material?

Source Code:

Form Code:

Generator Certification

18-AUG-2009 CSample Collect Date: Collector: Basis for Information:

I, ______________________________, hereby certify that all information submitted in this and all attached documents is, to the best of my knowledge, an accurate representation of the waste turned in to the DRMO. All known or suspected hazards have been disclosed.:

Generator's Representative: Date:

Special Handling Information: USE PERSONAL PROTECTIVE CLOTHING AND EQUIPMENT

Mngmt Method Ship Code:

Cost Unit

Unit Range Low

Material Constituents

Constituent Name Concentration Range Percent

PRIMARY & SECONDARY FILTERS FROM VOC CONTROL DEVICE 0 100

Source Code Comment:

N.O.S. Description 1:

N.O.S. Description 2:

UOM

Mngmt Method Ship Code Comment:

Form Code Comment:

Minimization Code:

Minimization Code Comment:

Upper Range (%)

Profile Sheet 21-DEC-20 18:28:13 Page 3

SENSITIVE BUT UNCLASSIFIED

Revision Date: Jan 2006

File details come from the government source that posted it. Updated .