About this file

This document provides building specifications for a public address system installation at a United States Coast Guard station. The installation will include approximately 19,000 feet of single pair shielded speaker wire to connect 44 interior drop ceiling speakers with volume control, 8 exterior horn speakers, 35 interior box speakers, 11 interior flush mount speakers, 12 Bogen TPU60 amplifiers, 9 Bogen TPU100 amplifiers, 2 Bogen PCM CPU's with power supplies, 6 Bogen zone modules, 1 Bogen telephone interface module, and various switches, connectors, mixers and modules. Spare equipment is also specified including additional quantities of speakers, wire, amplifiers, a CPU and zone module. Zone configuration will be determined during project kickoff. The related federal contract opportunity is solicitation number 70Z07924RUCPL0001 for USCG Telephony Lifecycle Support through the Department of Homeland Security Coast Guard.

View the file

Other files for this federal contract opportunity

Other files attached to USCG Telephony Lifecycle Support, newest first.
File Type Posted
70Z07924RUCPL00010006 USCG Telephony Lifecycle Support.pdf PDF
ATT I Pricing Sheet Telephony Lifecycle Support A0005.xlsx XLSX spreadsheet
70Z07924RUCPL00010005 USCG Telephony Lifecycle Support.pdf PDF
ATT IV PPQ USCG Telephony Lifecycle Support A0005.pdf PDF
70Z07924RUCPL00010004 Extend Solicitation Close Date.pdf PDF
70Z07924RUCPL00010003 Updates and Final Questions and Responses.pdf PDF
ATT IV PPQ USCG Telephony Lifecycle Support Rev1.pdf PDF
ATT I Pricing Sheet Telephony Lifecycle Support_A0003.xlsx XLSX spreadsheet
QandR A0003.pdf PDF
Task Order Pricing Sheet STA Ft Macon_A0003.xlsx XLSX spreadsheet
70Z07924RUCPL00010002 Questions and Responses 2.pdf PDF
70Z07923RUCPL0001A0001 Questions and Responses 1.pdf PDF
ATT II USCG Equipment Warranty.xlsx XLSX spreadsheet
ATT IV PPQ USCG Telephony Lifecycle Support.pdf PDF
70Z07924RUCPL0001 USCG Telephony Lifecycle Support IDIQ.pdf PDF
Task Order SOW Station Ft Macon PA System Install.pdf PDF
ATT I Pricing Sheet Telephony Lifecycle Support.xlsx XLSX spreadsheet
ATT III Wage Determination List 6-30-23.pdf PDF
Attachment-A-Station Ft Macon PA Install-Hardware Specifications.pdf PDF
Attachment-C Station Ft Macon Building Scematic.pdf PDF
Task Order Pricing Sheet STA Ft Macon.xlsx XLSX spreadsheet
Show all 21

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT B

USCG STATION FT MACON

PA SYSTEM INSTALLATION

BUILDING SPECIFICS

Provide all hardware and installation of speakers & amplifiers for one building with 18 zones.

The Hardware provided shall be Brand name or Equal as listed below. Refer to the Public Address Hardware Specifics for detailed descriptions.

Building specifics;

Station Building

1. Approx. 19,000 feet of single pair shielded speaker wire, PN: 2C18FS-CMR-GY-B-BED

2. 44 each, EZ interior drop ceiling speakers w/volume control, PN: SM4T

3. 8 each, exterior horn speakers, PN: SPT15

4. 35 each, interior box speakers, PN: WBS87T25BRV

5. 11 each, interior flush mount speaker, PN: S86T725PG8WBRVK

6. 12 each, Bogen TPU60 amplifiers, PN: TPU60B

7. 9 each, Bogen TPU100 amplifiers, PN: TPU100B

8. 2 each, Bogen PCM CPU’s with power supplies, PN: PCMCPU and PCMPS2.

9. 6 each, Bogen zone modules, PN: PCMZPM.

10. 1 each, Bogen telephone interface module, PN: PCMTIM.

11. 4 each, single pole / single throw toggle switches w/covers (for alarm, OPS).

12. 1 each, double pole / single throw toggle switch (for colors).

13. 1 each, 3.5mm stereo phono plug (for colors) (1 in OPS).

14. 2 each, Vector Mixer. PN: VMIX.

15. 1 each, Vector module, tone generator, PN: TNG1S.

16. 1 each, Vector module, relay in/out, PN: RIO1S.

17. 1 each, Vector module, mono aux input, PN: MAX1R.

18. 2 each, Line matching transformer, PN: WMT1 or equal.

Spares

1. Approx. 1,000 feet of single pair shielded speaker wire, PN: 2C18FS-CMR-GY-B-BED

2. 2 each, EZ interior drop ceiling speakers w/volume control, PN: SM4T

3. 2 each, exterior horn speakers, PN: SPT15

4. 2 each, interior box speakers, PN: WBS87T25BRV

5. 2 each, interior flush mount speaker, PN: S86T725PG8WBRVK

6. 1 each, Bogen TPU100 amplifiers, PN: TPU100B

7. 1 each, Bogen PCM CPU with power supply, PN: PCMCPU and PCMPS2.

8. 1 each, Bogen zone modules, PN: PCMZPM.

9. 1 each, Bogen telephone interface module, PN: PCMTIM.

10. 1 each, Vector Mixer. PN: VMIX.

11. 1 each, Vector module, tone generator, PN: TNG1S.

12. 1 each, Vector module, relay in/out, PN: RIO1S.

13. 1 each, Vector module, mono aux input, PN: MAX1R.

Zone configuration will be determined during the project kick-off.