Attachment B Grand Opera House Renovation.pdf

PDF 12 MB Posted

Attached to
26-002-LH GRAND OPERA HOUSE RENOVATION (8/14/25)
Solicitation number
PE-61100-NONST-2026-000000080
Issued by
Bibb County, Georgia

About this file

This file is a set of architectural working drawings and design documentation for the Grand Opera House located at 651 Mulberry Street in Macon, Georgia. The project involves comprehensive improvements and renovations to the historic assembly building, classified as Type III-B construction with an A-1 assembly occupancy designation. The scope of work includes renovation of basement-level dressing rooms with the addition of one ADA-compliant bathroom, renovation of three stage-level dressing rooms, and replacement of existing exterior doors serving restrooms and the green room. The total building area undergoing renovation is 2,465 square feet with a design occupant load of 165 persons. The project will not include automatic sprinkler or fire alarm system installation. The drawings are issued as limited service documents dated June 27, 2025, and include 36 total sheets covering architectural, mechanical, electrical, plumbing, and interior design disciplines.

The design documentation reflects compliance with applicable codes including the 2018 International Building Code with Georgia Amendments, 2018 International Fire Code, 2018 Life Safety Code, 2019 NFPA 72, 2018 International Plumbing and Mechanical Codes with Georgia Amendments, 2015 International Energy Conservation Code with 2023 National Electrical Code, and the 2010 Americans with Disabilities Act Standards for Accessible Design. The architectural team is BTBB Inc. (609 Cherry Street, Macon, Georgia), with consulting firms including Total Engineering for mechanical and plumbing services and Camp Interiors for interior design. The contractor is responsible for coordinating all trades and utilizing professional experience to develop complete pricing estimates, as the drawings provide limited service guidance for typical conditions only.

View the file

Other files

File Type Posted
26_002_LH Grand Opera House Renovation IFB.pdf PDF
26_002_LH Pre_Bid Sign in Log.pdf PDF
26_002_LH_ Addendum 2.pdf PDF
Official Bid Tabulation 2.pdf PDF
Attachment A.pdf PDF
Official Bid Tabulation 1.pdf PDF
Notice of Solicitaton Action.pdf PDF
26_002_LH_ Addendum_1.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Rules and Regulations of the Safety Fire Commissioner Chapter 120-3-3

Safety Fire Commissioner Chapter 120-3-20.-02(2)(b) as adopted and amended by the Rules and Regulations of the

2010 Americans with Disabilities Act Standards for Accessible Design

Georgia Amendments

2015 International Energy Conservation Code with

2023 National Electrical Code

Fire Code Commissioner Chapter 120-3-3.-04(53) adopted and amended by the Rules and Regulations of the Safety

2019 edition of NFPA 72 (National Fire Alarm and Signaling Code), as

2018 International Plumbing Code with Georgia Amendments

2018 International Mechanical Code with Georgia Amendments

Chapter 120-3-3.-04(72)

Regulations of the Safety Fire Code Commissioner

2018 Life Safety Code as adopted and amended by the Rules and

Chapter 120-3-3.-04(3)

Rules and Regulations of the Safety Fire Code Commissioner

2018 International Fire Code as adopted and amended by the

2018 International Building Code with Georgia Amendments

CONSULTANTS :

BUILDING CODE ANALYSIS :

APPLICABLE CODES

PROJECT TITLE :

VICINITY MAP :

DRAWING INDEX : 36 TOTAL

GENERAL INFORMATION - 3

PROJECT NARRATIVE:

ARCHITECTURAL - 8

LS1.1

G1.2

G1.1

Life Safety Plan

General Information

Title Sheet, Drawing Index & Code Summary

Permit Set

BUILDING DATA

CONSTRUCTION TYPE:

USE CLASSIFICATION(S):

OCCUPANCY TYPE:

DESIGN OCCUPANT LOAD:

TOTAL BUILDING AREA TO BE RENOVATED:

CHANGE OF USE:

AUTO SPRINKLER SYSTEM:

FIRE ALARM SYSTEM:

DEFFERED SUBMITTALS (Separate permit)

G1.1 & Code Summary

Drawing Index Title Sheet, IMPROVEMENTS FOR:

GRAND OPERA HOUSE

651 MULBERRY STREET MACON, GEORGIA

A8.1

A3.2

A3.1

A2.1

A1.2

A1.1

EX1.2

EX1.1

Reflected Ceiling Plan

Exterior Elevations

Exterior Elevations

Door Types & Details

Main Level Floor Plan

Basement Floor Plan

Existing Main Level Plan

Existing Basement Plan

MULBERRY ST.

TYPE III-B

ASSEMBLY

ASSEMBLY - A-1

SF

NO

NO

EXISTING

Replacement of existing exterior doors-restrooms & green room

Renovation of basement level dressing rooms, -include 1-ADA bathroom).

Renovation of 3 dressing rooms at stage level (to -

ELECTRICAL

Electrical Design Consultants

Macon, Georgia 31201 175 New Street, Suite 1

MECHANICAL

Total Engineering

Macon, Georgia 31201 169 New Street

AND FOR COMPLYING WITH APPLICABLE CODES AND REQUIREMENTS.

CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING OTHER TRADES

IN ADDITION TO THE INFORMATION PROVIDED ON THESE DRAWINGS, THE

SUPPLEMENT THE INFORMATION PROVIDED ON THESE DRAWINGS.

THE OWNER ON COMPONENTS TO BE INCORPORATED INTO THE WORK TO

AND KNOWLEDGE IN ESTIMATING SIMILAR PROJECTS AND TO CONFER WITH

THESE DRAWINGS. IT WILL BE REQUIRED OF HIM TO USE HIS EXPERIENCE

PRICING ESTIMATE BASED SOLELY ON THE INFORMATION CONTAINED IN

ADDRESSED. THIS MEANS THE ESTIMATOR CANNOT PREPARE A COMPLETE

ALLOWANCES TO COVER CONDITIONS NOT SHOWN OR DIRECTLY

ESTIMATE. IT IS THEREFORE REQUIRED THAT THE ESTIMATOR MAKE

ASSISTING THE ESTIMATOR IN THE PREPARATION OF HIS PRICING

THE FUNCTION OF THESE DRAWINGS IS TO SERVE AS A GUIDE IN

AND DETAILS HAVE BEEN ADDRESSED.

AND EVERY MEMBER OR CONDITION. ONLY THE TYPICAL MEMBERS

THERE HAS BEEN NO ATTEMPT MADE TO DETAIL OR LABEL EACH

THESE DRAWINGS ARE ISSUED AS LIMITED SERVICE DRAWINGS ONLY.

2,465

TOTAL = 165 PERSONS

TOTAL BASEMENT AREA TO BE RENOVATED 2,465 = 165 PERSONS / 15

TOTAL BASEMENT AREA TO BE RENOVATED

MECHANICAL - 5

ELECTRICAL - 11

INTERIOR DESIGN - 6

ID900

ID800

ID700

ID600

ID500

ID400

Reflected Ceiling Plan

Exterior Elevations

Exterior Elevations

Door Types & Details

Main Level Floor Plan

Basement Floor Plan

INTERIOR DESIGN

Camp Interiors

Macon, Georgia 31201 1080 3rd Street, Suite 400

M2.2

M2.1

M1.2

M1.1

M0.1

Main Level Mechanical Plan - New Work

Main Level Mechanical Plan - Demo

Basement Mechanical Plan - New Work

Basement Mechanical Plan - Demo

Mechanical Schedules

E4.2

E4.1

E3.2

E3.1

E2.3

E2.2

E2.1

E1.2

E1.1

E0.2

E0.1

Electrical Details & Schedules

Power Riser Diagram, Details, & Schedules

Main Level Floor Plan - Power & Systems

Basement Floor Plan - Power & Systems

Floor Plans - Stage Lighting Controls

Main Level Floor Plan - Lighting

Basement Floor Plan - Lighting

Main Level - Electrical Demolition

Basement - Electrical Demolition

Electrical Specifications

Electrical Legends, Specifications, & Schedules

PLUMBING - 3

P2.1

P1.1

P0.1

Main Level Plumbing Plan

Basement Plumbing Plan

Plumbing Specifications

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

G

.1

T it le S h e e t, D r a w in g

I n d e x

C o d e S u m m a r y

.d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

2025-08

S T

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

Permit Set6-27-2025

CLEARANCES AT DOORS

STANDARD ADA MANEUVERING

X

X Y

Y

Y

ADA NOTES :

HC.

M A

X

2'-0" 1'-0"

STANDARD WHEELCHAIR ACCESSIBLE STALLS

STANDARD ADA CLEARANCES

56" MIN.

59" MIN.

42" MIN.

TYPICAL ADA WHEELCHAIR REACH RANGES

"AMERICANS WITH DISABILITIES ACT".

ALL HANDICAPPED ACCESSORIES AND FIXTURES SHALL CONFORM TO THE

THE FOLLOWING NOTES FROM THE ADA GUIDELINES SHALL BE USED

ABOVE FINISHED FLOOR.

DOOR PASSAGE SHALL BE MOUNTED NO HIGHER THAT 4'-0"

USABLE FROM BOTH SIDES. HARDWARE REQUIRED FOR ACCESSIBLE

FULLY OPEN, OPERATING HARDWARE SHALL BE EXPOSED AND

HANDLES ARE ACCEPTABLE DESIGNS. WHEN SLIDING DOORS ARE

OPERATED MECHANISMS, PUSH-TYPE MECHANISMS, AND U-SHAPED

TIGHT GRASPING OR TWISTING OF THE WRIST TO OPERATE. LEVER -

THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE

OPERATING DEVICES ON ACCESSIBLE DOORS SHALL HAVE A SHAPE

DOOR HARDWARE. HANDLES, PULLS, LATCHES, LOCKS AND OTHER 4.13.9

2.

1.

4.13.10

MEASURED TO THE LEADING EDGE OF THE DOOR.

SECONDS TO MOVE TO A POINT 3 IN FROM THE LATCH,

POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3

OF THE CLOSER SHALL BE ADJUSTED SO THAT FROM AN OPEN

DOOR CLOSER. IF A DOOR HAS A CLOSER, THEN THE SWEEP PERIOD

4.13.11

(C) SLIDING OR FOLDING DOORS: 5 LBS.

(B) INTERIOR HINGED DOORS: 5 LBS.

(A) EXTERIOR HINGED DOOR: (RESERVED).

(2) OTHER DOORS.

ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY.

(1) FIRE DOORS SHALL HAVE THE MINIMUM OPENING FORCE

PULLING OPEN A DOOR SHALL BE AS FOLLOW:

DOOR OPENING FORCE. THE MAXIMUM FORCE FOR PUSHING AND

MAY HOLD THE DOOR IN A CLOSED POSITION.

RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT

THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO

FRONT EDGE OF THE FOUNTAIN.

BE POSITIONED SO THE FLOW OF WATER IS WITHIN 3" OF THE

FOUNTAIN WITH A ROUND OR OVAL BOWL, THE SPOUT MUST

UNDER THE FLOW OF WATER. ON AN ACCESSIBLE DRINKING

HIGH SO AS TO ALLOW THE INSERTION OF A CUP OR GLASS

THE SPOUT SHALL PROVIDE A FLOW OF WATER AT LEAST 4"

PARALLEL OR NEARLY PARLLEL TO THE FRONT OF THE UNIT.

SHALL DIRECT THE WATER FLOW IN A TRAJECTORY THAT IS

WATER COOLERS SHALL BE AT THE FRONT OF THE UNIT AND

SPOUT LOCATION. THE SPOUTS OF DRINKING FOUNTAINS AND4.15.3

4.16.6

DO NOT PERMIT CONTINUOUS PAPER FLOW SHALL NOT BE USED.

THIS SHEET. DISPENSERS THAT CONTROL DELIVERY, OR THAT

WITHIN REACH, AS SHOWN ON WATER CLOSET DRAWING

DISPENSERS. TOILET PAPER DISPENSERS SHALL BE INSTALLED

4.17.5

REDUCED TO A MINIMUM OF 3'-6"

DOOR SIDE OF THE STALL AND ANY OBSTRUCTION MAY BE

THE LATCH SIDE OF THE STALL DOOR, CLEARANCE BETWEEN THE

SHALL COMPLY WITH 4.13. IF TOILET STALL APPROACH IS FROM

DOORS. TOILET STALL DOORS, INCLUDING DOOR HARDWARE,

4.18.3

WITH 2'-5" CLEARANCE BETWEEN THEM.

THE FRONT EDGE OF THE URINAL RIM MAY BE PROVIDED

ACCESSIBLE ROUTE SHIELDS THAT DO NOT EXTEND BEYOND

APPROACH. THIS CLEAR SPACE SHALL JOIN OR OVERLAP AN

SHALL BE PROVIDED IN FRONT OF URINALS TO ALLOW FORWARD

CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE 2'-6" BY 4'-0"

4.19.4

BE NO SHARP OR ABRASIVE SURFACES UNDER LAVATORIES.

CONFIGURED TO PROTECT AGAINST CONTACT. THERE SHALL

UNDER LAVATORIES SHALL BE INSULATED OR OTHERWISE

EXPOSED PIPES AND SURFACES. HOT WATER AND DRAIN PIPES

4.27.4

GREATER THAN 5 LBS.

FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO

GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE

OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT

OPERATION. CONTROLS AND OPERATING MECHANISMS SHALL BE

GRAB BARS

BLOCKING FOR

PROVIDE SOLID

GRAB BAR

WATER CLOSET

GRAB BAR

WATER CLOSETS DISPENSER

TOILET TISSUE

A D

U L

T

C H

IL

D

R E

N

M

IN

CLEARANCES

LAVATORY

WATER PIPES

AND EXPOSED HOT

INSULATE TRAP

MIRROR

DISPENSER

SOAP

DISPENSER

PAPER TOWEL

CLEARANCE

6" MAX. TOE

TO WALL

ON HANDRAIL

RETURN END

CLEARANCE

MIN. KNEE

CLEARANCE

MIN. KNEE

CLEARANCES

FOUNTAINS

DRINKING

17" TO 19"

AREA

IN SHADED

PERMITTED

EQUIPMENT

CLEARANCE

6" MAX. TOE

URINAL

MIRROR

DEPTH

MIN.

M

A X

M

IN

LIMITS: HIGH AND LOW

UNOBSTRUCTED SIDE REACH

LIMITS: HIGH AND LOW

UNOBSTRUCTED FORWARD REACH HANDRAIL

TO WALL

ON HANDRAIL

RETURN END

2 RAILS ARE NOT USED

34" AT ALL LOCATIONS WHERE

ADULT HANDRAIL HT. SHALL BE

* NOTE:

STAIR HANDRAIL EXTENSIONS

OF ONE TREAD THAT IS REQUIRED AT EACH BOTTOM RISER.

Y IS THE MIN. HANDRAIL EXTENSION OF THE WIDTH

AT EACH TOP RISER.

NOTE: X IS THE 1'-0" MIN. HANDRAIL EXTENSION REQUIRED

SIGN

AT IN SWINGING DOORS

AT OUT SWINGING DOORS

PEEPHOLE

PEEPHOLE

ADA

HANDLE

DOOR

SIGNAGE FIRE EXTINGUISHER

THRESHOLD

DOOR

SELF-CLOSING

GRAB BAR

18" VERTICAL

DOOR LOCATION

ALTERNATE

CLEAR

MIN.

MAX.

4"

C L

E A

R M

IN

42" MIN.

12" MAX

W/ WALL MTD. WC

W/ FLOOR MTD. WC

GRAB BAR

18" VERTICAL

SPACE

FLOOR

CLEAR

MIN.

W/WALL MOUNTED WC

W/FLR MOUNTED WC

ONLY. OTHER APPROACHES = 4'-0" MIN.

MIN. LATCH APPROACH

SPACE

FLOOR

CLEAR

MIN.

CLEARANCES

LAVATORY

M

IN

M A

X

M

IN

M A

X

T O

SPACE

FLOOR

CLEAR

MIN.

CLEARANCES

FOUNTAINS

DRINKING

/4

T

O

/2

/4

M

A X

CHANGE IN LEVEL

ACCESSIBLE ROUTE

/2

M

A X

DOOR THRESHOLDS

ACCESSIBLE ROUTE

M

IN

DOORWAY

CLEAR

MINIMUM

FRONT APPROACHES - SWINGING DOORS

PULL SIDE

2'-0" PREFERRED

1'-6" MIN.

M

IN

PUSH SIDE

LATCH.

A CLOSER AND A

DOOR HAS BOTH

NOTE X = 1'-0" IF X = 3'-6" MIN. IF Y = 4'-6"

NOTE X = 3'-0" MIN. IF Y = 5'-0"

PULL SIDE

HINGE SIDE APPROACHES - SWINGING DOORS

LATCH.

A CLOSER AND A

IF DOOR HAS BOTH

NOTE Y = 4'-0" MIN.

PUSH SIDE

IF DOOR HAS CLOSER.

NOTE Y = 4'-6" MIN.

PULL SIDE

2'-0" MIN.

X

Y

M

IN

LATCH SIDE APPROACHES - SWINGING DOORS

PUSH SIDE

2'-0" MIN.

X

IF DOOR HAS CLOSER .

NOTE Y = 4'-0" MIN.

M

IN

MIN.

M

IN

M

IN

M

IN

M

IN

M

IN

10" MAX.

1 1/4" TO 1 1/2" 2 1/4"

1'-0" MIN. X

1'-6"

M

IN

C L

E A

R

M A

X A

D U

L T

O F

L A

V

O R

S

IN

K

T O

R

IM

MAX.

HC.

TOILET PARTITION

TO WALL OR

2'-8" MIN.

4'-6"

32"

M

IN

54" MIN.

36" 56" MIN.

59" MIN.

M

IN

2'-6"

2'-6"

N

O N

-A D

A

P E

R F

E R

E D

1'-0"

TREAD

/2

48"

30"

M A

X

42" 18" 39"-41"

3'-6"1'-0"

A D

U L

T

M

IN

7" - 9"

M A

X

M

IN

M

IN

M A

X A

D U

L T

8"

17"

M

IN

8"

M

IN

Information General

G1.2

A D

U L

T

C H

IL

D

R E

N

CHILDREN*

ADULT18"

12"

C H

IL

D

R E

N

* CHILDREN DIMENSIONS ARE BASE ON AGES 3-4.

A D

U L

T

C H

IL

D

R E

N

M

IN

A D

U L

T

C H

IL

D

R E

N

A D

U L

T

C H

IL

D

R E

N

A D

U L

T

C H

IL

D

R E

N

M

A X

M

A X

M A

X C

H

IL

D

M

IN

C

H

IL

D

34" CHILDREN*

C H

IL

D

R E

N

M A

X C

H

IL

D R

E N

C H

IL

D

M

IN

M A

X C

H

IL

D R

E N

C H

IL

D

M

IN

Y Y

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

G

.2

G e n e r a l

I n f o r m a ti o n

.d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

LS1.1

Life Safety Plan

UP

UP

UP

UP

6 R.

UP

RAMP UP

LIFT

UP

LIFE SAFETY PLAN

1/4" = 1'-0"

BREAK

ELEC/

WOMEN MEN

WARDROBE

DRESSING

WOMEN'S

DRESSING

MEN'S

GREEN ROOM

SHOWER

MECH.

LIFT

STACK

DRYER

WASH. WASH.

WASH.

W.H.

W.H.

HVAC

ELEC.

STAIR

G A

S

ELEC.

ELEC.

ELEC.

ELEC.

ELEC. ELEC.

E L

E C

ELEC.

SHOWER

102103

107 109

106 108

NO WORK

TA-1 TA-1

TRAVEL DISTANCE: 69'-4"

LEGEND

FE.1

FIRE EXTINGUISHER TYPE: 4A-80 BC

EXIT PATH

EXIT LIGHT

FE.1

FE.1

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts

\W o r k in g D r a w in g s \2

L

S .1

L if e S a f e ty

P la n .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

EX1.1

Basement Plan Existing

UP

UP

UP

UP

6 R.

UP

RAMP UP

LIFT

UP

EXISTING BASEMENT PLAN

1/4" = 1'-0"

BREAK

ELEC/

WOMEN MEN

WARDROBE

DRESSING

WOMEN'S

DRESSING

MEN'S

GREEN ROOM

SHOWER SHOWER

MECH.

LIFT

STACK

DRYER

WASH. WASH.

WASH.

W.H.

W.H.

HVAC

ELEC.

D.S.

STAIR

G A

S

RADIATOR

13'-1" X 14'-4"

8'-6" X 16'-0" 9'-0" X 16'-0"

13'-4" X 13'-9"

17'-9" X 23'-0"

15'-0" X 18'-4" 17'-3" X 11'-3"

4'-0"

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

E

X

.1 E x is ti n g B a s e m e n t P la n

.d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

UP

UP

UP

DN.

DN.

UP

UP

DN.

UP

F E D C

B A

H G

F

F E D C

B A

H G

F

EX1.2

Level Plan Existing Main

EXISTING MAIN LEVEL PLAN

1/4" = 1'-0"

DRESS.

DRESS.

SHOWER

TOILET TOILET

JAN.

UP

UP UP

J H G

KLMNPQR

S

J

K

L

M

NP

Q

R

S T

U

QRST

J H G

KLMNPQR

S

J

K

L

Q

R

S T

U

UP UP

RIGGING RIGGING

L A

D D

E R

RAD.ELEC.

ELEC.ELEC.

E L

E C

E L

E C

E L

E C

CONDUITS

MTR.

D.S. D.S.

RAD.

R A

D

R

IG

G

IN

G

R

IG

G

IN

G

ACOUSTICAL SHELL

MOVEABLE

OFFICE

SEATS

SEATS

STAGE

SEATS

PIT

ORCH

E

D G

E O

F S

T A

G E

L

IN

E O

F C

E

IL

IN

G

B R

E A

K

A R

C H

L

IN

E O

F F

IR

S

T B

A L

C O

N Y

L

IN

E O

F S

E C

O N

D B

A L

C O

N Y

AUDITORIUM

DRESS.

LIFT

6'-0"

6'-6"

6'-0"

6'-6" 3'-6"

4'-0"

7'-0" X 8'-8" 6'-8" X 8'-8"

13'-3" X 8'-8"

7'-9" X 4'-6" 7'-11" X 4'-0"

3'-6" X 3'-9"

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

E

X

.2 E x is ti n g M a in

L e v e l

P la n .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

A1.1

Floor Plan Basement

UP

UP

UP

UP

6 R.

UP

RAMP UP

LIFT

UP

BASEMENT FLOOR PLAN

1/4" = 1'-0"

BREAK

ELEC/

WOMEN MEN

WARDROBE

DRESSING

WOMEN'S

DRESSING

MEN'S

GREEN ROOM

SHOWER

MECH.

LIFT

STACK

DRYER

WASH. WASH.

WASH.

W.H.

W.H.

HVAC

ELEC.

STAIR

G A

S

A

A

A

A

A

A

A

A

A

A

B

ELEC.

ELEC.

ELEC.

ELEC.

ELEC. ELEC.

E L

E C

ELEC.

SHOWER

102103

107 109

106 108

NO WORK

A

TO WALL AS DECOR

IN SPACE 204; INSTALL MIRRORS IN ALL PANELS; DOORS TO BE MOUNTED

SALVAGE EXISTING DOOR TO DRESSING ROOM 203 AND TO EXISTING SHOWER 3)

IN SPACE NOS. 102, 103, 107, 109, 201, 202, 203, 204 (REFER TO INTERIORS)

INSTALL 5/8" DENSGLASS TILE BACKER BOARD AT WALL TILE 2)

SPACE NOS. 107, 108, 204 (REFER TO INTERIORS)

INSTALL 5/8" DENGLASS TILE BACKER BOARD AT SHOWERS - 1)NOTES:

TA-1 TA-1

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts

\W o r k in g D r a w in g s \2

A

.1

B a s e m e n t

F lo o r P la n .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

UP

UP

DN.

DN.

UP

UP

DN.

UP

F E D C

B A

H G

F

F E D C

B A

H G

F

A1.2

Floor Plan Main Level

MAIN LEVEL FLOOR PLAN

1/4" = 1'-0"

DRESS.

DRESS.

H/C TOILET

UP

UP UP

J H G

KLMNPQR

S

J

K

L

M

NP

Q

R

S T

U

QRST

J H G

KLMNPQR

S

J

K

L

Q

R

S T

U

UP UP

L A

D D

E R

ELEC.

ELEC.ELEC.

E L

E C

E L

E C

E L

E C

CONDUITS

MTR.

OFFICE

SEATS

SEATS

STAGE

SEATS

PIT

ORCH

L

IN

E O

F C

E

IL

IN

G

B R

E A

K

A R

C H

L

IN

E O

F F

IR

S

T B

A L

C O

N Y

L

IN

E O

F S

E C

O N

D B

A L

C O

N Y

AUDITORIUM

DRESS.

LIFT

201 202

A.1

C

C

D

EX

A.1

EXEX

E

ON A3.1

SEE DTL: 1

ON A3.1

SEE DTL: 1

ON A3.1

SEE DTL: 1

ALUM. ADA DOOR THRESHOLD RAMP W/ CLOSED ENDS - SEE HARDWARE SCHEDULE

RAD.

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts

\W o r k in g D r a w in g s \2

A

.2

M a in

L e v e l

F lo o r P la n .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

A2.1

& Details Door Types

CB D E FA

7'-6" M.O. 6'-6" M.O. 4'-0" M.O. 4'-0" M.O. 3'-9" M.O.

DOOR TYPES

1/4" = 1'-0"

J-2 J-3

EXISTING WOOD TRIM TRIM O/ 2X

CEMENTITIOUS

TRIM O/ 2X

CEMENTITIOUS

NEW HOLLOW METAL FRAME

EXISTING BRICK

J-2 J-2 J-2 J-2J-3J-1

H-1

STUD WALL

NEW OR EXISTING

FRAME

HOLLOW METAL

METAL FRAME

DOOR IN HOLLOW

CORE FLUSH WOOD

3'-0" INTERIOR SOLID

MOULDING EACH SIDE

METAL DOORS W/ APPLIED

PAIR 3'-6" EXTERIOR

EXTERIOR DOORS

PAIR 3'-0"

EXTERIOR DOOR

3'-6"

EXTERIOR DOOR

3'-6"

EXTERIOR DOOR

3'-3"

DOOR DETAILS

1 1/2" = 1'-0"

3'-0"

G

W/ TRANSOM

EXTERIOR DOORS

PAIR 3'-0"

J-2

H-2

J-1

TRIM O/ 2X

CEMENTITIOUS

W/ WEATHER BARRIER

O/ PLYWD SHEATHING

CEMENTITIOUS TRIM

NEW HOLLOW METAL FRAME

EXISTING WOOD TRIM

CAULK JOINT

A

J-1

METAL FRAME

DOOR IN HOLLOW

3'-0" INTERIOR PANEL

3'-0"

H-2

H E

IG

H

T V

A R

IE

S

H-2 H-2 H-2

H-2

H-2

H-1H-1

FOR DOORS NOT SHOWN ON PLANS

NOTE: SEE EXTERIOR ELEVATIONS

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

A

.1

D o o r T y p e s

D e ta il s .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

A3.1

Elevations Exterior

L3 x3 xr

TYP. WINDOW DETAIL1

A3.1

FIRST STREET ELEVATION

1/8"=1'-0"

3/4"=1'-0"

2X6 STUDS W/ R.21 INSULATION

INSET 1/2" - PAINT

MDO PLYWD. AT INTERIOR SIDE,

BARRIER; SEAL & PAINT

HARDIE PANEL O/ WEATHER

SEAL SEAL

C

C

E

D

E

C

C

C

C

F

G

A3.1

TYP. WINDOW HEAD DETAIL2

A3.1 3/4"=1'-0"

EX. BRICK WALL

EX. BRICK WALL

INSET 1/2" - PAINT

MDO PLYWD. AT INTERIOR SIDE,

2X6 STUDS W/ R.21 INSULATION

BARRIER; SEAL & PAINT

HARDIE PANEL O/ WEATHER

SEAL

ACT

A3.1

W.2 W.2 W.2 W.2 W.2 W.2

W.2W.2W.2W.2W.2

W.2 W.2

W.2 W.2

W.2 W.2 W.2

W.2 W.2 W.2

W.2 W.2

W.2 W.2

W.2 W.2

W.2 W.2

W.2

W.1 W.1 W.1 W.1 W.1 W.1 W.1

W.1

W.1

W.1

W.1 W.1

W.1

W.2

W.2

EXISTING LOUVER

EXISTING LOUVER

EXISTING LOUVER

TO REMAIN

EXISTING A/C UNIT

NOTE: REMOVE EXTERIOR WINDOW

LEGEND

W.2 SEAL & PAINT AT FORMER WINDOW OPENING

W.1 REMOVE EXISTING WINDOW & CLOSE OPENING PER DETAILS 1/A3.1 & 2/A3.1 - SEAL & PAINT

F P

R O

J E

C T

S

G r a n d O p e r a H o u s e I m p r o v e m e n t s W o r k i n g D r a w i n g s

A

.1

E x t e r i o r E l e v a t i o n s .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

A3.2

Elevations Exterior

REAR ELEVATION

1/8" = 1'-0"

LIFT

B

LEGEND

W.2 SEAL & PAINT AT FORMER WINDOW OPENING

W.1 REMOVE EXISTING WINDOW & CLOSE OPENING PER DETAILS 1/A3.1 & 2/A3.1 - SEAL & PAINT

W.2 W.2

W.2 W.2

W.2 W.2

W.2 W.2

W.2W.2W.2

W.2W.2

W.2 W.2 W.2

SEAL & PAINT

F P

R O

J E

C T

S G r a n d O p e r a H o u s e I m p r o v e m e n t s W o r k i n g D r a w i n g s A

.2

E x t e r i o r E l e v a t i o n s .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

A8.1 Ceiling Plan Reflected

Basement Level

BREAK

ELEC/

WOMEN MEN

WARDROBE

DRESSING

WOMEN'S

DRESSING

MEN'S

GREEN ROOM

SHOWER

MECH.

SHOWER

102103

107 109

106 108

NO WORK

NOT IN SCOPE

REFLECTED CEILING PLAN

1/4"=1'-0"

F

P R

O J E

C T

S \2

G r a n d O p e r a H o u s e I m p r o v e m e n ts \W o r k in g

D r a w in g s \2

A

.1

R e f le c te d C e il in g

P la n .d g n

PLANNERSARCHITECTS

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

the user.

of liability and risk sole the at is drawing this on information the of use Any use. future any for professional design the of approval and review any implies drawing this of use the that indicate to or exact are etc details, dimensions, all that anyone to guarantee or warranty express any provide to construed be not should drawing this of delivery The

478.742.1208 / www.btbbinc.com

609 Cherry Street, Macon, GA 31201

G R

A N

D O

P E

R A

H O

U S

E

M A

C O

N

G E

O R

G

IA

M

U L

B E

R R

Y S

T

IM

P

R O

V E

M E

N T

S F

O R

A

T E

OF GE

O

R G

IA

W. BROWN

ROBERT

R E

G

ISTERED ARCHI

T E

C

TR

E

G

ISTERED ARCHI

T E

C T

C E R

T

IFICATE N

o

PLUMBING SPECIFICATIONS

GENERAL PLUMBING NOTES:

LEGEND

FIXTURE AND EQUIPMENT SCHEDULE

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-049 www.totalengineers.com P0.1

PLUMBING

SPECIFICATIONS

BASEMENT PLUMBING PLAN1

KEYED NOTES: (THIS SHEET ONLY)

ELEC/

BREAK

WOMEN MEN

WARDROBE

WOMEN'S

DRESSING

MEN'S

DRESSING

GREEN ROOM

SHOWER

MECH.

STAIR

SHOWER

102103

107 109

106 108

LIFT

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-049 www.totalengineers.com P1.1

BASEMENT

PLAN

MAIN LEVEL PLUMBING PLAN1

KEYED NOTES: (THIS SHEET ONLY)

DRESS.

DRESS.

H/C TOILET

OFFICE

SEATS

SEATS

STAGE

SEATS

ORCH

PIT

AUDITORIUM

DRESS.

LIFT

201 202

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-049 www.totalengineers.com P2.1

MAIN LEVEL

PLAN

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-052 www.totalengineers.com M0.1

MECHANCAL

SCHEDULES

BASEMENT MECHANICAL PLAN - DEMO1

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-052 www.totalengineers.com M1.1

BASEMENT

MECHANICAL

PLAN - DEMO

BASEMENT MECHANICAL PLAN - NEW WORK1

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-052 www.totalengineers.com M1.2

BASEMENT

PLAN - NEW WORK

MAIN LEVEL MECHANICAL PLAN - DEMO1

DRESS.

DRESS.

SHOWER

TOILET TOILET

JAN.

DRESS.

Drawing Issue Schedule

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-052 www.totalengineers.com M2.1

MAIN LEVEL

PLAN - DEMO

MAIN LEVEL MECHANICAL PLAN - NEW WORK1

Project No:

© COPYRIGHT 2025 BTBB inc.

NOT FOR REPRODUCTION

The delivery of this drawing should not be construed to provide any express warranty or guarantee to anyone that all dimensions, details, etc are exact or to indicate that the use of this drawing implies any review and approval of the design professional for any future use.

Any use of the information on this drawing is at the sole risk and liability of the user.

609 Cherry Street, Macon, GA 31201

478.742.1208 / www.btbbinc.com

G R

AN

D

O

PE

R A

H O

U

SE

M U

LB

ER

R Y

ST

M

AC

O N

, G

EO

R G

IA

IM

PR

O

VE

M

EN

TS

F

O R

2025-08

169 New Street, Macon, GA 31201 (478)741-4632 - T.E. project # 25-052 www.totalengineers.com M2.2

MAIN LEVEL

PLAN - NEW WORK

2025-08 G1.1 Title Sheet, Drawing Index & Code Summary 6-27-2025
2025-08 G1.2 General Information 6-27-2025
2025-08 LS1.1 Life Safety Plan 6-27-2025
2025-08 EX1.1 Existing Basement Plan 6-27-2025
2025-08 EX1.2 Existing Main Level Plan 6-27-2025
2025-08 A1.1 Basement Floor Plan 6-27-2025
2025-08 A1.2 Main Level Floor Plan 6-27-2025
2025-08 A2.1 Door Types & Details 6-27-2025
2025-08 A3.1 Exterior Elevations 6-27-2025
2025-08 A3.2 Exterior Elevations 6-27-2025
2025-08 A8.1 Reflected Ceiling Plan 6-27-2025
2025-08 ID400 Finish Plan 6-27-2025
2025-08 ID500 Lighting Plan & RCP 6-27-2025
2025-08 ID600 Plumbing Fixtures, Toilet Accessories 6-27-2025
2025-08 ID700 Power Plan, Furniture Plan, Interior Signage 6-27-2025
2025-08 ID800 Interior Elevations 6-27-2025
2025-08 ID900 Interior Elevations, Details 6-27-2025
2025-08 P0.1 Plumbing Specifications 6-27-2025
2025-08 P1.1 Basement Plumbing Plan 6-27-2025
2025-08 P2.1 Main Level Plumbing Plan 6-27-2025
2025-08 M0.1 Mechanical Schedules 6-27-2025
2025-08 M1.1 Basement Mechanical Plan - Demo 6-27-2025
2025-08 M1.2 Basement Mechanical Plan - New Work 6-27-2025
2025-08 M2.1 Main Level Mechanical Plan - Demo 6-27-2025
2025-08 M2.2 Main Level Mechanical Plan - New Work 6-27-2025
2025-08 E0.1 Electrical Legends, Specifications, & Schedules 6-27-2025
2025-08 E0.2 Electrical Specifications 6-27-2025
2025-08 E1.1 Basement - Electrical Demolition 6-27-2025
2025-08 E1.2 Main Level - Electrical Demolition 6-27-2025
2025-08 E2.1 Basement Floor Plan - Lighting 6-27-2025
2025-08 E2.2 Main Level Floor Plan - Lighting 6-27-2025
2025-08 E2.3 Floor Plans - Stage Lighting Controls 6-27-2025
2025-08 E3.1 Basement Floor Plan - Power & Systems 6-27-2025
2025-08 E3.2 Main Level Floor Plan - Power & Systems 6-27-2025
2025-08 E4.1 Power Riser Diagram, Details, & Schedules 6-27-2025
2025-08 E4.2 Electrical Details & Schedules 6-27-2025

File details come from the government source that posted it. Updated .