NAVAL STATION - NORFOLK, VIRGINIA
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND
MID-ATLANTIC
DESIGN AND CONSTRUCTION
FACILITIES ENGINEERING AND ACQUISITION DIVISION
NORFOLK, VIRGINIA
03/01/2022 - FINAL SUBMITTAL
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
2:
:0
PM
C :\R ev it
L oc al F ile s\
LA
G
-2 7_
9_
A_ R
_s eb as tia n.
ra m os .rv t
GI001
BU
IL
DI
NG
L
AG
-2
CO
VE
R
SH
EE
T
ALP
12,862,930
SAR SAR
03/01/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
S. M. SWEENEY, P.E.
N/A
M
ID
LA
N
T
PW
D N
O R
FO
LK
G I0
BUILDING LAG-27
COMPLETE BUILDING REPAIR/RENOVATION
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
WILLOUGHBY BAY
NAVAL SUPPORT
ACTIVITY
U.S. NAVAL STATION
SEWELLS POINT
NORFOLK
U.S. NAVAL
AIR STATION
CHESAPEAKE BAY
LITTLE CREEK
U.S. NAVAL
AMPHIBIOUS BASE
VA BEACH
OCEANA
NAVAL AIR
STATION
CHESAPEAKE
SOUTHERN BRANCH
EASTERN BRANCH
ST. JULIEN'S CREEK
U.S. NAVAL ANNEX
ELIZABETH RIVER
58 460
PORTSMOUTH
U.S. ARMY CRANEY
ISLAND DISPOSAL AREA
NANSEMOND RIVER
WESTERN BRANCH
CRANEY
ISLAND NAVY
DEPOT
PROJECT SITE
NORTH
ROOM
A1 A-201
ROOM IDENTIFIER
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
A-401 INTERIOR ELEVATION
INDICATOR
INTERIOR ELEVATION NUMBER
SHEET WHERE DRAWN
DETAIL NUMBER
SHEET
REFERENCED FROM
EXTERIOR ELEVATION
INDICATOR
ELEVATION NUMBER
DIRECTION OF VIEW
SHEET WHERE DRAWN
A1 A-301
WALL / PARTIAL
BUILDING SECTION
INDICATOR
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
A1 A-301
BUILDING SECTION
INDICATOR
SECTION NUMBER
SHEET WHERE DRAWN
A1 A-301
BUILDING
NEW WORK
KEYNOTE INDICATOR
KEYNOTE NUMBER
DEMOLITION
KEYNOTE INDICATOR
KEYNOTE NUMBER
A-901 PHOTOGRAPH
INDICATOR
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
A1
PLAN
NORTH
TRUE NORTH
A-501
A1
A1
A1
A1 VIEW TITLE
SCALE: 1/8" = 1'-0" (A-101)
PLAN TITLE
SCALE: 1/8" = 1'-0"
A1
PROJECT SITE
LAG-27
LAG-88
LAG-109
M-114
LAG-30
MASSEY HUGHES DR
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
2:
:1
PM
C :\R ev it
L oc al F ile s\
LA
G
-2 7_
9_
A_ R
_s eb as tia n.
ra m os .rv t
GI002
BU
IL
DI
NG
L
AG
-2
G
EN
ER
AL
P
RO
JE
CT
N O
TE
S
SY
M
BO
LS
ALP
12,862,931
SAR SAR
03/01/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
S. M. SWEENEY, P.E.
N/A
M
ID
LA
N
T
PW
D N
O R
FO
LK
G I0
VICINITY MAP
GOVERNING REGULATIONS
LOCATION MAP
1 WHERE EXISTING CONSTRUCTION IS DAMAGED BY CONSTRUCTION
REQUIRED BY THESE DOCUMENTS. REPAIR THE DAMAGED ITEM(S) WITH
MATERIALS TO MATCH THE ADJACENT MATERIAL, TEXTURE AND COLOR.
2 FIELD VERIFY EXISTING DIMENSIONS (INDICATED AS “±") PRIOR TO
BEGINNING DEMOLITION, ORDERING MATERIALS, OR PROCEEDING WITH
WORK. NOTIFY THE CONTRACTING OFFICER, IN WRITING, OF
DISCREPANCIES.
3 ALL ITEMS NOT SHOWING AS "EXISTING" MUST BE PROVIDED AND
INSTALLED UNDER THE REQUIREMENTS OF THIS CONTRACT.
4 ITEMS INDICATED TO “REMOVE” MUST BE DISPOSED OF OFF SITE UNLESS
INDICATED OTHERWISE.
5 COORDINATE LAY DOWN AREA WITH THE CONTRACTING OFFICER PRIOR TO
THE PRECONSTRUCTION MEETING. THE ALLOWABLE AREA SIZE MUST BE
ESTABLISHED BY THE CONTRACTING OFFICER.
6 CONSTRUCTION WILL BE ACCOMPLISHED IN AND AROUND AREAS WHICH
WILL REMAIN OPERATIONAL. AVOID INTERFERENCE WITH THE
OPERATIONAL WORK ROUTINE.
7 ALL SUBMITTALS REQUIRED BY THESE DRAWINGS OR SPECIFICATIONS
MUST BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL TO
COMMENCEMENT OF RELATED WORK.
8 PRIOR TO DEMOLITION WORK, VERIFY AND DOCUMENT THAT EXISTING
ITEMS TO REMAIN ARE IN PROPER WORKING ORDER. IF ITEMS ARE FOUND
DAMAGED OR IN DISREPAIR, NOTIFY THE CONTRACTING OFFICER, IN
WRITING, UPON DISCOVERY.
9 COMPARE AND ANALYZE THE CONTRACT DOCUMENTS WITH EACH OTHER.
NOTIFY THE CONTRACTING OFFICER, IN WRITING, OF ERRORS,
INCONSISTENCIES, AND OMISSIONS DISCOVERED. CONSTRUCTION ACTIVITY
PERFORMED KNOWING IT INVOLVES A RECOGNIZED ERROR,
INCONSISTENCY, OR OMISSION IN THE CONTRACT DOCUMENTS WITHOUT
SUCH NOTICE TO THE CONTRACTING OFFICER, ASSUMES RESPONSIBILITY
FOR SUCH PERFORMANCE. CONTRACTOR WILL BEAR THE AMOUNT OF THE
COST OF CONSTRUCTION TO CORRECT.
BUILDING CODE:
UNIFIED FACILITIES CRITERIA (UFC) 1-200-01 (01 OCT. 2020)
UNIFIED FACILITIES CRITERIA (UFC) 1-200-02 (01 DEC. 2020)
UNIFIED FACILITIES CRITERIA (UFC) 3-110-03 (12 JUNE 2020)
INTERNATIONAL BUILDING CODE (IBC) 2018
ACCESSIBILITY CODE:
UNIFORM ACCESSIBILITY STANDARDS (UFAS)
AMERICANS WITH DISABILITIES ACT (ADA)
ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
ACCESSIBILITY GUIDELINES FOR BUILDINGS AND FACILITIES (ADAAG)
MECHANICAL CODE:
INTERNATIONAL MECHANICAL CODE (IMC) 2018
ELECTRICAL CODE:
NFPA 70, NATIONAL ELECTRIC CODE (NEC) 2020
PLUMBING CODE:
INTERNATIONAL PLUMBING CODE (IPC) 2018
GENERAL PROJECT NOTES
FIRE PREVENTION & LIFE SAFETY CODE:
UNIFIED FACILITIES CRITERIA (UFC) 3-600-01 (12 AUG. 2020) FIRE PROTECTION
ENGINEERING FOR FACILITIES, WITH CHANGES 6 (06 MAY 2021)
NFPA 101, LIFE SAFETY CODE, 2018
SY
M
DE
S C
RI
PT
I O N
DA
TE
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
2:
:1
PM
C :\R ev it
L oc al F ile s\
LA
G
-2 7_
9_
A_ R
_s eb as tia n.
ra m os .rv t
GI003
BU
IL
DI
NG
L
AG
-2
LI
ST
O F
SH
EE
TS
ALP
12,862,932
SAR SAR
03/01/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
S. M. SWEENEY, P.E.
N/A
M
ID
LA
N
T
PW
D N
O R
FO
LK
G I0
LIST OF SHEETS LIST OF SHEETS CONTINUED
SY
M
DE
S C
RI
PT
I O N
DA
TE
AP
PR
SHEET NO.
NAVFAC DWG. NO. SHEET TITLENO. SHEET
ELECTRICAL
70 E-001 12,862,999 ELECTRICAL SYMBOLS, LEGEND, ABBREVIATIONS, AND NOTES
71 ED101 12,863,000 FLOOR PLAN - DEMOLITION
72 EL101 12,863,001 FLOOR PLAN - LIGHTING
73 EL501 12,863,002 LIGHTING DIAGRAMS, DETAILS, AND SCHEDULES
74 EL502 12,863,003 LIGHTING DIAGRAMS, DETAILS, AND SCHEDULES
75 EP101 12,863,004 FLOOR PLAN - POWER
76 EP501 12,863,005 POWER DIAGRAMS, DETAILS, AND SCHEDULES
77 EP601 12,863,006 POWER RISER DIAGRAM
TELECOMMUNICATIONS
78 TT101 12,863,007 FLOOR PLAN - TELECOMMUNICATIONS & SPECIAL SYSTEMS
79 TT501 12,863,008 TELECOMMUNICATIONS DIAGRAMS, DETAILS, AND SCHEDULES
SHEET NO.
NAVFAC DWG. NO. SHEET TITLENO. SHEET
GENERAL
1 GI001 12,862,930 COVER SHEET
2 GI002 12,862,931 GENERAL PROJECT NOTES & SYMBOLS
3 GI003 12,862,932 LIST OF SHEETS
HAZARDOUS MATERIALS
4 HM101 12,862,933 HAZARDOUS MATERIALS PLAN
CIVIL
5 CD101 12,862,935 CIVIL DEMOLITION PLAN
6 C-001 12,862,934 CIVIL GENERAL NOTES, LINE TYPES & SYMBOLS
7 CU101 12,862,937 CIVIL UTILITY PLAN
8 CS101 12,862,936 CIVIL SITE PLAN
9 C-501 12,862,938 CONCRETE DETAILS
10 C-502 12,862,939 WATER & SANITARY SEWER DETAILS
11 C-503 12,862,940 WATER METER DETAILS
STRUCTURAL
12 S-001 12,862,941 STRUCTURAL NOTES - GENERAL, CONCRETE, REINFORCING
13 S-002 12,862,942 STRUCTURAL NOTES - STEEL, TIMBER, ANCHORS, SYMBOLS, LEGEND, ABBREVAITIONS
14 SD101 12,862,943 DEMOLITION FOUNDATION AND GROUND FLOOR PLAN
15 SD501 12,862,944 DETAILS - DEMO
16 SD901 12,862,945 REFERENCE PHOTOS
17 S-101 12,862,946 FOUNDATION AND GROUND FLOOR PLAN
18 S-102 12,862,947 ROOF FRAMING PLAN
19 S-301 12,862,948 SECTIONS - ROOF FRAMING
20 S-302 12,862,949 SECTIONS - ROOF PLAN & DETAILS
21 S-401 12,862,950 ENLARGED FLOOR PLAN - EQUIPMENT FRAME
22 S-501 12,862,951 DETAILS
ARCHITECTURE
23 AE001 12,862,952 ARCHITECTURAL NOTES AND SYMBOLS
24 AD101 12,862,953 FIRST FLOOR PLAN - DEMOLITION
25 AD102 12,862,954 MEZZANINE PLAN - DEMOLITION
26 AD103 12,862,955 REFLECTED CEILING PLAN - DEMOLITION
27 AD104 12,862,956 ROOF PLAN - DEMOLITION
28 AD201 12,862,957 SOUTH AND WEST EXTERIOR ELEVATIONS - DEMOLITION
29 AD202 12,862,958 NORTH AND EAST EXTERIOR ELEVATIONS - DEMOLITION
30 AD901 12,862,959 PHOTO REFERENCE PLAN
31 AD902 12,862,960 REFERENCE PHOTOGRAPHS
32 AD903 12,862,961 REFERENCE PHOTOGRAPHS
33 AD904 12,862,962 REFERENCE PHOTOGRAPHS
34 AE101 12,862,963 FIRST FLOOR PLAN - NEW WORK
35 AE102 12,862,964 FIRST FLOOR REFLECTED CEILING PLAN - NEW WORK
36 AE103 12,862,965 ROOF PLAN - NEW WORK
37 AE201 12,862,966 SOUTH AND WEST EXTERIOR ELEVATIONS - NEW WORK
38 AE202 12,862,967 NORTH AND EAST EXTERIOR ELEVATIONS - NEW WORK
39 AE203 12,862,968 INTERIOR ELEVATIONS
40 AE204 12,862,969 INTERIOR ELEVATIONS
41 AE301 12,862,970 BUILDING SECTIONS
42 AE401 12,862,971 ENLARGED PLANS
43 AE402 12,862,972 ENLARGED PLANS
44 AE501 12,862,973 INTERIOR DETAILS
45 AE601 12,862,974 DOOR SCHEDULE AND DETAILS
46 AE602 12,862,975 WINDOW DETAILS
47 AE603 12,862,976 INTERIOR PARTITION TYPES AND DETAILS
INTERIORS
48 IN101 12,862,977 FIRST FLOOR FINISH PLAN - NEW WORK
49 IN102 12,862,978 FINISH SCHEDULE, SIGNAGE SCHEDULE, AND DETAILS
PLUMBING
50 P-001 12,862,979 PLUMBING LEGEND, ABBREVIATIONS AND NOTES
51 PD101 12,862,980 FLOOR PLAN - DEMOLITION - PLUMBING
52 P-101 12,862,981 FLOOR PLAN -NEW WORK - DRAIN AND WASTE
53 P-102 12,862,982 FLOOR PLAN - NEW WORK - WATER
54 P-501 12,862,983 PLUMBING DETAILS
55 P-502 12,862,984 PLUMBING DETAILS
56 P-503 12,862,985 PLUMBING DETAILS
57 P-601 12,862,986 PLUMBING SCHEDULES
58 P-701 12,862,987 DOMESTIC WATER DIAGRAM
59 P-702 12,862,988 SANITARY AND VENT DIAGRAM
MECHANICAL
60 M-001 12,862,989 MECHANICAL LEGEND, ABBREVIATIONS AND NOTES
61 MD101 12,862,990 FIRST FLOOR PLAN - DUCTWORK
62 M-101 12,862,991 FLOOR PLAN
63 M-301 12,862,992 SECTION PLANS
64 M-302 12,862,993 SECTION PLANS
65 M-501 12,862,994 MECHANICAL DETAILS
66 M-502 12,862,995 MECHANICAL DETAILS
67 M-601 12,862,996 MECHANICAL SCHEDULES
68 M-701 12,862,997 MECHANICAL CONTROLS
69 M-702 12,862,998 MECHANICAL CONTROLS
DW
REF.
A
B
C
D
E
2 3 4 5 6 7 8 9
1 1
6'-6 1/2" ± 6'-9" ± 21'-6 3/4" ± 19'-8 3/4" ± 32'-8 3/4" ± 6'-10 3/4" ±
12'-10 1/2" ± 19'-10 1/4" ± 6'-10 3/4" ±
'-1
'-2 3/
4"
'-3
3/ 4"
'-2
1/ 2"
'-5
SYMBOL DESCRIPTION
ASBESTOS CONTAINING FLOOR TILE AND MASTIC
LEAD PAINT ON EXISTING TIMBER STRUCTURE AND
WOOD SHEATHING BOARDS TO BE REMEDIATED
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
1:
:5
AM
C :\R ev it
L oc al F ile s\
LA
G
-2 7_
9_
A_ R
_s eb as tia n.
ra m os .rv t
HM101
BU
IL
DI
NG
L
AG
-2
HA
ZA
RD
O
US
M
AT
ER
IA
LS
P
LA
N
SCS
12,862,933
SAR SAR
03/01/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
S. M. SWEENEY, P.E.
N/A
M
ID
LA
N
T
PW
D N
O R
FO
LK
H M
HAZ MAT KEYNOTESGENERAL SHEET NOTES HAZARDOUS MATERIALS LEGEND#
0 2' 4' 8'
PLAN
NORTH
SCALE: 1/4" = 1'-0" (AD201)
FIRST FLOOR HAZARDOUS MATERIALS PLAN
5 REFER TO SHEET G-002 FOR ADDITIONAL PROJECT NOTES.
6 REFER TO SHEET A-001 FOR ADDITIONAL ARCHITECTURAL NOTES.
1 THE WORK WILL REQUIRE THE REMEDIATION OF ASBESTOS-CONTAINING
MATERIALS AND LEAD PAINT AS INDICATED. DESTRUCTIVE ACTIVITIES SUCH
AS BREAKING INTO WALLS, CEILINGS, AND FLOORS WAS NOT PERFORMED IN
ORDER TO LOCATE MATERIALS. IF SUSPECT MATERIALS ARE UNCOVERED,
THE CONTRACTOR MUST STOP WORK UNTIL THE MATERIALS ARE PROPERLY
IDENTIFIED AND ADDRESSED.
2 CONTRACTOR MUST REMOVE AND DISPOSE OF ALL HAZARDOUS MATERIAL
IN ACCORDANCE WITH STATE AND LOCAL REQUIREMENTS.
3 REMOVE AIR CONDITIONING, REFRIGERATION, AND OTHER EQUIPMENT
CONTAINING REFRIGERANTS WITHOUT RELEASING CHLOROFLUOROCARBON
REFRIGERANTS TO THE ATMOSPHERE IN ACCORDANCE WITH THE CLEAN AIR
ACT AMENDMENT OF 1990. RECOVER ALL REFRIGERANTS PRIOR TO
REMOVING AIR CONDITIONING, REFRIGERATION, AND OTHER EQUIPMENT
CONTAINING REFRIGERANTS AND DISPOSE OF IN ACCORDANCE WITH THE
PARAGRAPH ENTITLED "DISPOSAL OF OZONE DEPLETING SUBSTANCE (ODS)
IN SPECIFICATION SECTION, 02 41 00, "DEMOLITION".
4 CONTRACTOR MUST ASSUME THAT ALL PAINTED SURFACES IN THE EXISTING
SPACE ARE POSITIVE FOR LEAD-BASED PAINT.
1 EXISTING ASBESTOS CONTAINING FLOOR TILE AND MASTIC IN SHADED AREA.
FOR BASIS OF BIDS, CONTRACTOR TO ASSUME A TOTAL OF 1,100 SQUARE
FEET (SF) OF (2) LAYERS OF FLOOR TILE AND MASTIC IS TO BE ABATED AS
ASBESTOS CONTAINING MATERIAL.
2 REMEDIATE ALL LOOSE AND FLAKING LEAD BASED PAINT ON EXISTING
PAINTED TIMBER STRUCTURE (COLUMNS, BEAMS, BRACING MEMBERS,
RAFTERS, RIDGE BOARDS, ETC.), ASSOCIATED METAL FASTENERS AND
COMPONENTS (BOLTS, BRACKETS, PLATES, ETC.), AND EXISTING ROOF
SHEATHING BOARDS TO REMAIN WITH DRY ICE BLASTING OR SIMILAR
NON-ABRASIVE METHODS. FOR BIDDING PURPOSES ASSUME A TOTAL OF 8,800
SQUARE FEET (SF) OF PAINTED SURFACES CONTAINING LEAD BASED PAINT.
SY
M
DE
S C
RI
PT
I O N
DA
TE
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
C-001
BENCH MARK - NSN 19
GENERAL NOTES ALL SHEETS
EROSION AND SEDIMENT CONTROL GENERAL NOTES
CIVIL ABBREVIATIONS CIVIL LEGEND
N/A
GRAPHIC SCALE
BUILDING LAG-27 - CIVIL SITE PLAN
GENERAL SHEET NOTES
NEW WORK KEYNOTES
IP
EROSION & SEDIMENTATION LEGEND
IP
IP
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
CD101
IP
PARTIAL PLAN VIEW - PAVEMENT REPLACEMENT
GENERAL SHEET NOTES
NEW WORK KEYNOTES
PARTIAL PLAN LEGEND
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
CS101
BUILDING LAG-27 - CIVIL UTILITY PLAN
GENERAL SHEET NOTES
NEW WORK KEYNOTES
IP
EROSION & SEDIMENTATION LEGEND
IP
IP
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
CU101
IP
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
C-501
CONCRETE PAVEMENT A1
DOWELED CONSTRUCTION JOINT (DJ)C3
THICKEN EDGE JOINT BETWEEN NEW AND EX. PAVEMENT (TEJ)C1
EXPANSION JOINT (EJ)D3
DETAIL B
DETAIL A
CONTRACTION JOINT (CJ)C5
TYPICAL CONCRETE SIDEWALKA3
DETAIL B
JOINT TYPE USE IN TOTAL SLAB REPLACEMENT
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
C-502
UTILITY LINE CROSSING
CLEANOUT DETAIL
AMI PULSE TRANSMITTING WATER METER DETAIL PIPE TRENCH/PAVEMENT PATCH DETAIL
TYPICAL SANITARY SEWER LATERAL DETAIL
B3
A3A1 A5
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
C O
M M
AN
D~
M
ID
-A
TL
AN
TI
C
BU
IL
DI
NG
L
AG
-2
- R
EN
O
VA
TI
O
N
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O N
C-503
EXISTING WATER METER COMMUNICATIONS DETAIL
WATER METER INSTALLATION WIRING DETAIL
WATER METER SHEET NOTES WATER METER SYMBOL LEGEND
WATER LATERAL CONNECTION ASSEMBLY DETAILA1 A4
C3
CAST-IN-PLACE CONCRETE REINFORCING BAR LAP SPLICE SCHEDULE
TENSION BARS COMPRESSION BARS
BAR SIZE
FY = 60
KSI
f'c = 3,000 PSI
REGULAR
CLASS
A B
TOP
CLASS
A B f'c = 3,500 PSI
REGULAR
CLASS
A B
TOP
CLASS
A B f'c = 4,000 PSI
REGULAR
CLASS
A B
TOP
CLASS
A B f'c = 5,000 PSI
REGULAR
CLASS
A B
TOP
CLASS
A B
17" 22" 28" 33" 48" 55" 62" 70" 78"
22" 22"#3 #4 #5 #6 #7 #8 #9
#10 #11
28" 38" 47" 56" 81" 93"
105" 118" 131"
16" 21" 26" 31" 45" 51" 58" 65" 73"
21" 27" 34" 40" 59" 67" 75" 85" 94"
26" 36" 44" 52" 75" 87" 98"
110" 122"
15" 19" 24" 29" 42" 48" 54" 61" 67"
19" 25" 31" 37" 54" 62" 70" 79" 87"
25" 33" 41" 49" 71" 81" 91"
102" 114"
13" 17" 22" 26" 38" 43" 48" 54" 60"
17" 23" 28" 34" 49" 56" 63" 71" 78"
22" 29" 36" 44" 63" 72" 81" 92"
102"
12" 15" 19" 23" 27" 30" 34" 39" 43"
29"29" 36" 43" 63" 72" 81" 91"
101"
36" 43" 63" 72" 81" 91"
101"
21" 27" 34" 40" 59" 67" 75" 85" 94"
19" 25" 31" 37" 54" 62" 70" 79" 87"
17" 23" 28" 34" 49" 56" 63" 71" 78" f'c = ALL
NOTES (THESE NOTES MUST BE USED FOR ALL SPLICES UNLESS OTHERWISE NOTED ON DRAWINGS):
1. TOP BARS ARE HORIZONTAL BARS, SPLICED SO THAT 12" OR MORE OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE REINFORCING BAR.
2. CLASS A SPLICES MAY BE USED ONLY WHEN 50% OR LESS OF THE BARS ARE SPLICED WITHIN THE LAP SPLICE LENGTH.
3. CLASS B SPLICES MUST BE USED FOR ALL SPLICES IN SLABS, BEAMS, JOISTS, WALLS, MOMENT RESISTING COLUMNS, AND JAMB COLUMNS, UNLESS THEY MEET THE
REQUIREMENTS OF NOTE #2 ABOVE.
4. TIES AND STIRRUPS MUST NOT BE SPLICED UNLESS OTHERWISE APPROVED BY THE ENGINEER OR RECORD. ROUND COLUMN TIES MAY BE SPLICED USING CLASS A
LAPS.
5. FOR ALL LIGHTWEIGHT CONCRETE, LAP LENGTHS MUST BE MULTIPLIED BY 1.3.
6. THE BAR LAP SPLICE LENGTHS MUST BE MULTIPLIED BY 1.5 WHEN EITHER OF THE FOLLOWING IS TRUE:
A. CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN ONE BAR DIAMETER, CLEAR COVER IS LESS THAN ONE BAR DIAMETER AND STIRRUPS OR TIES ALONG THE
LENGTH OF THE SPLICE ARE LESS THAN THE CODE MINIMUM
B. CLEAR SPACING OF BARS BEING DEVELOPED IS LESS THAN TWO BAR DIAMETERS AND CLEAR COVER IS LESS THAN ONE BAR DIAMETER.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
:0
5:
A M
C :\R ev it
Lo ca l F ile s\
LA
G
-1
-S -R
_k im be rly .a
.d av is 2.
rv t
S-001
B U
IL
D
IN
G
L A
G -2
ST
RU
CT
UR
AL
N
O
TE
S -G
EN
ER
AL
, C
O
NC
RE
TE
, R
EI
NF
O
RC
IN
G
DSG
12,862,941
KAD KAD
3/1/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
M
ID
LA
N T
PW
D
N O
R
FO
LK
S. M. SWEENEY, P.E.
N/A
1 STRUCTURAL DRAWINGS MUST BE USED IN CONJUNCTION WITH DRAWINGS
OF ALL OTHER DISCIPLINES AND THE SPECIFICATIONS. VERIFY
REQUIREMENTS OF OTHER TRADES AS TO SLEEVES, CHASES, HANGERS,
INSERTS, ANCHORS, HOLES AND OTHER ITEMS TO BE PLACED OR SET IN THE
STRUCTURAL WORK AS WELL AS TO BE TEMPORARILY DISCONNECTED AND
RECONNECTED TO ALLOW FOR THE INSTALLATION OF THE STRUCTURAL
WORK.
2 THE CONTRACTOR IS RESPONSIBLE FOR COMPLYING WITH SAFETY
PRECAUTIONS AND REGULATIONS DURING THE WORK. THE STRUCTURAL
ENGINEER WILL NOT ADVISE ON, NOR ISSUE DIRECTION AS TO SAFETY
PRECAUTIONS AND PROGRAMS.
3 STRUCTURAL DRAWINGS HEREIN REPRESENT THE FINISHED STRUCTURE.
PROVIDE ALL TEMPORARY SHORING, TEMPORARY SUPPORTS, GUYING AND
BRACING REQUIRED TO ERECT AND HOLD THE STRUCTURE IN PROPER
ALIGNMENT UNTIL ALL STRUCTURAL WORK AND CONNECTIONS HAVE BEEN
COMPLETED. THE INVESTIGATION, DESIGN, SAFETY, ADEQUACY AND
INSPECTION OF ERECTION BRACING, SHORING, TEMPORARY SUPPORTS, ETC.,
IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
4 THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR THE METHODS,
TECHNIQUES, AND SEQUENCES OF PROCEDURES TO PERFORM THE WORK.
SUPERVISION OF WORK IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
5 DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
WHERE CONDITIONS ARE NOT SPECIFICALLY SHOWN, USE SIMILAR DETAILS
OF CONSTRUCTION, SUBJECT TO APPROVAL BY THE CONTRACTING OFFICER.
6 ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS
TO BE FIELD ERECTED MUST BE SUPERVISED BY THE SUPPLIER DURING
MANUFACTURING, DELIVERY, HANDLING, STORAGE AND ERECTION IN
ACCORDANCE WITH THE SUPPLIER’S INSTRUCTIONS AND REQUIREMENTS.
7 LOADING APPLIED TO THE STRUCTURE DURING THE PROCESS OF
CONSTRUCTION MUST NOT EXCEED THE SAFE LOAD-CARRYING CAPACITY OF
STRUCTURAL MEMBERS. LIVE LOADINGS USED IN DESIGN OF THIS
STRUCTURE ARE INDICATED IN "DESIGN CRITERIA NOTES". DO NOT APPLY
ANY CONSTRUCTION LOADS UNTIL STRUCTURAL FRAMING IS PROPERLY
CONNECTED TOGETHER AND UNTIL ALL TEMPORARY BRACING IS IN PLACE.
8 ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF
THESE STANDARDS, UNLESS OTHERWISE NOTED.
9 SHOP DRAWINGS AND OTHER ITEMS MUST BE SUBMITTED FOR REVIEW BY
THE GENERAL CONTRACTOR PRIOR TO FABRICATION. ALL SHOP DRAWINGS
MUST BE REVIEWED BY THE GENERAL CONTRACTOR BEFORE SUBMITTAL.
THE REVIEW IS TO BE FOR CONFORMANCE WITH THE DESIGN CONCEPT AND
GENERAL COMPLIANCE WITH THE RELEVANT CONTRACT DOCUMENTS. THE
REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY
TO REVIEW, CHECK, AND COORDINATE THE SHOP DRAWINGS PRIOR TO
SUBMISSION. THE CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR
ERRORS AND OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP
DRAWINGS AS THEY PERTAIN TO MEMBER SIZES, DETAILS, DIMENSIONS, ETC.
ANY PROPOSED CHANGES MUST BE SUMITTED IN A LETTER OR DETAIL TO THE
CONTRACTING OFFICER FOR APPROVAL.
10 IN NO CASE MAY REPRODUCTION OF THE CONTRACT DRAWINGS BE USED AS
SHOP DRAWINGS. SUBCONTRACTOR / FABRICATOR MUST PROVIDE
INDEPENDENTLY CREATED DRAWINGS BASED ON THE PLANS AND DETAILS.
11 IN ACCORDANCE WITH THE IBC, SPECIAL INSPECTIONS WILL BE REQUIRED
FOR THIS PROJECT. SPECIAL INSPECTIONS MUST BE PERFORMED IN
ACCORDANCE WITH THE "SCHEDULE OF SPECIAL INSPECTIONS". THE
CONTRACTOR MUST NOTIFY THE SPECIAL INSPECTOR AT LEAST 48 HOURS IN
ADVANCE FOR WORK THAT WILL REQUIRE INSPECTION OR TESTING. THE
CONTRACTOR MUST EMPLOY THIRD PARTY SPECIAL INSPECTOR.
12 CONTRACTOR MUST VISIT THE SITE PRIOR TO BID TO ASCERTAIN CONDITIONS
WHICH MAY ADVERSELY AFFECT THE WORK OR COST THEREOF.
13 THE CONTRACTOR MUST FIELD VERIFY THE DIMENSIONS, ELEVATIONS,
INTERFERENCES AND OTHER REQUIREMENTS NECESSARY FOR THE PROPER
CONSTRUCTION AND ALIGNMENT OF NEW PORTIONS OF THE STRUCTURE TO
EXISTING. THE CONTRACTOR MUST MAKE ALL MEASUREMENTS NECESSARY
FOR FABRICATION AND ERECTION OF STRUCTURAL MEMBERS.
DISCREPANCIES MUST BE BROUGHT TO THE ATTENTION OF THE
CONTRACTING OFFICER PRIOR TO ORDERING MATERIALS OR BEGINNING
WORK (CONSTRUCTION OR DEMOLITION).
14 ALL ITEMS NOTED TO BE DEMOLISHED OR REMOVED WILL BECOME THE
CONTRACTOR'S PROPERTY AND MUST BE REMOVED FROM GOVERNMENT
PROPERTY, UNLESS OTHERWISE NOTED. DISPOSITION OF THE ITEMS /
MATERIALS IS THE RESONSIBILITY OF THE CONTRACTOR AND MUST ADHERE
WITH ALL APPLICABLE FEDERAL, STATE, AND LOCAL REGULATIONS.
15 TAKE CARE NOT TO DAMAGE THE EXISTING STRUCTURE. WHERE EXISTING
CONSTRUCTION IS DAMAGED BY CONSTRUCTION REQUIRED BY THESE
DOCUMENTS, REPAIR THE DAMAGED ITEM(S) WITH MATERIALS TO MATCH THE
ADJACENT MATERIAL, TEXTURE, AND COLOR.
16 DO NOT HANG ITEMS FROM THE EXISTING STRUCTURE, UNLESS OTHERWISE
NOTED.
GENERAL NOTES DESIGN CRITERIA NOTES
1 THE STRUCTURAL WORK TO BE PERFORMED UNDER THIS CONTRACT HAS
BEEN DESIGNED TO THE APPLICABLE DESIGN STANDARD AND / OR CRITERIA
OF THE FOLLOWING, UNLESS OTHERWISE NOTED:
A. ACI 318-14, “BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE”
B. ACI 530-13, “BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES”
C. AISI S100-16, "SPECIFICIATION FOR THE DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS"
D. ANSI/AISC 360-10, “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS”
E. ASCE 7-16, “MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES”
F. INTERNATIONAL BUILDING CODE 2018
G. INTERNATIONAL EXISTING BUILDING CODE 2018
H. SDI RD-2017, "STEEL DECK INSTITUTE STANDARD FOR STEEL ROOF DECK"
I. SJI 100-15, "STANDARD SPECIFICATIONS, LOAD TABLES, AND WEIGHT TABLES
FOR STEEL JOISTS AND JOIST GIRDERS"
J. UFC 1-200-01 (08 OCTOBER 2019, CH1 01 OCTOBER 2020), “DOD BUILDING
CODE”
K. UFC 3-301-01 (01 OCTOBER 2019), "STRUCTURAL ENGINEERING"
L. ALL ASTM AND OTHER REFERENCES ARE PER THE LATEST EDITIONS OF
THESE STANDARDS AT THE CONTRACT AWARD DATE
2 THE LATERAL LOAD RESISTING SYSTEM FOR THIS STRUCTURE CONSISTS
PRIMARILY OF TIMBER BRACED FRAME WITH TIMBER ROOF RAFTERS AND
WOOD PLANK ROOF DIAPHRAGM.
3 DESIGN GRAVITY LIVE LOADS USED IN THE DESIGN OF THESE STRUCTURES
ARE AS FOLLOWS:
A. ROOF = 20 PSF
B. FLOORS = 100 PSF
C. EQUIPMENT PAD = 150 PSF
D. HANDICAP RAMP = 100 PSF
E. LANDING & STAIRS = 100 PSF
F. HANDRAIL SYSTEM
DESIGNED FOR A CONCENTRATED LOAD = 200 LBS
AND A DISTRIBUTED LOAD = 50 PLF
APPLIED IN ANY DIRECTION ALONG THE TOP RAIL (CONCENTRATED AND
UNIFORM LOADS ANALYZED INDEPENDENTLY PER IBC)
4 DESIGN LATERAL LIVE LOADS USED IN THE DESIGN OF THIS STRUCTURE ARE
AS FOLLOWS:
A. BUILDING CRITERIA: RISK CATEGORY = II
B. SNOW LOADS:
-GROUND SNOW LOAD = 10 PSF
-EXPOSURE FACTOR, CE = 1.0
- THERMAL FACTOR, CT = 1.2
C. WIND LOADS:
- BASIC WIND SPEED, V (ULTIMATE) = 118 MPH
- BASIC WIND SPEED, V (NOMINAL) = 92 MPH
- WIND EXPOSURE CATEGORY = D
- PRESSURE COEFFICIENT, GCPI = ±0.18
D. SEISMIC LOADS:
- SEISMIC IMPORTANCE FACTOR = 1.0
- SOIL SITE CLASS = D
- SEISMIC DESIGN CATEGORY = B
- 0.2 SEC SPECTRAL RESPONSE ACCEL, SS = 0.096G
- 1.0 SEC SPECTRAL RESPONSE ACCELERATION, S1 = 0.048G
- DEFLECTION AMPLIFICATION FACTOR, CD = 1.5
- RESPONSE MODIFICATION FACTOR, R = 1.5
"TIMBER FRAMES "
1 GENERAL SCOPE OF WORK INCLUDES BUT IS NOT LIMITED TO:
- CONCRETE WORK:
-- DEMO OF CURB (DAMAGED AND/OR IN WAY OF WORK), ~200 LF
-- DEMO OF EXTERIOR 8-9" THICK EQUIPMENT PADS
(CONCRETE / CMU / STEEL MIX), TYPICAL OF (2) LOCATIONS, ~85 SF
-- DEMO OF INTERIOR 5-6" THICK RAISED FLOOR
(CONCRETE / EPOXY), TYPICAL OF (2) LOCATIONS, ~250 SF
-- TRENCHING OF INTERIOR SLAB IN PREPARATION FOR PIPING, ~240 SF
-- ROUGHEN INTERIOR SLAB IN PREPARATION FOR LEVEL SURFACE
(PREPARATION FOR ARCHITECTURAL FLOOR FINISHES), ~3700 SF
-- INFILL INTERIOR SLAB RAMP DEPRESSIONS,
TYPICAL OF (2) LOCATIONS, ~150 SF
-- CURBING (REPLACEMENT AND ADJUSTED OPENINGS), ~180 LF
-- INTERIOR 6" THICK EQUIPMENT PAD, TYPICAL OF (1) LOCATION, ~9 SF
-- INFILL OF TRENCHED SLAB, ~240 SF
-- REINFORCED COLUMN PEDESTALS, TYPICAL OF (20) LOCATIONS
- STEEL WORK:
-- EQUIPMENT FRAME FOR MECHANICAL UNITS, TYIPCAL OF (1) LOCATION
- TIMBER / LUMBER WORK:
-- DEMO COLUMN SEGMENT IN WAY OF COLUMN BASE WORK,
TYPICAL OF (20) LOCATIONS. NOTE: TEMPORARY SHORING REQUIRED.
-- RESTORE DIAGONAL 3X8 ROOF BRACE, TYPICAL OF (1) LOCATION
AT COLUMN LINE 8, ~7.5 LF. FOR BID PURPOSES ASSUME OCCURS AT
SOUTH HALF OF COLUMN LINE 9 AND (1) OTHER LOCATION FOR (3) TOTAL
-- REPAIR ROOF SAG TO INCLUDE COLLAR TIES, TYPICAL OF (3) LOCATIONS
IN THE END BAY, BETWEEN COLUMN LINES 8 AND 9
- AND INCIDENTAL RELATED WORK AS SHOWN ON DRAWINGS OF OTHER
DISCIPLINES.
GENERAL SCOPE OF WORK
1 SPECIAL INSPECTIONS MUST BE COMPLETED FOR THE FOLLOWING
ELEMENTS ACCORDING TO IBC SECTION 1704.
2 CONCRETE AND ELEMENTS EMBEDDED IN CONCRETE MUST BE SPECIAL
INSPECTED PRIOR TO AND DURING PLACEMENT OF CONCRETE. SPECIAL
INSPECTIONS MUST INCLUDE THE FOLLOWING:
A. PERIODIC INSPECTION:
1. REINFORCING STEEL SIZE AND PLACEMENT
2. VERIFY USE OF APPROVED MIX DESIGN
3. AFTER PLACEMENT TO ENSURE ADEQUATE CURING AND
WEATHER PROTECTION PROCEDURES
4. SURFACE PREPARATION AND DETAILS AT COLD JOINTS, INCLUDING
PLACEMENT OF KEYWAYS
B. CONTINUOUS INSPECTION:
1. BOLTS TO BE INSTALLED IN CONCRETE PRIOR TO AND DURING
PLACEMENT OF CONCRETE
3 STRUCTURAL STEEL FABRICATION AND ERECTION MUST BE SPECIAL
INSPECTED AS FOLLOWS:
A. PERIODIC INSPECTION:
1. HIGH-STRENGTH BOLTS, NUTS AND WASHERS ACCORDING TO
AISC 360-10
2. SINGLE-PASS FILLET WELDS LESS THAN OR EQUAL TO 5/16"
3. FLOOR AND ROOF DECK WELDS
4. STEEL FRAME JOINT DETAILS FOR COMPLIANCE WITH CONSTRUCTION
DOCUMENTS INCLUDING MEMBER LOCATIONS, CONNECTION DETAILS
AND ANY OTHER BRACING AND STIFFENING DETAILS
B. CONTINUOUS INSPECTION:
1. SLIP-CRITICAL CONNECTIONS ACCORDING TO AISC 360-10.
2. FILLET WELDS GREATER THAN 5/16" AND ALL MULTI-PASS WELDS
3. GROOVE WELDS, INCLUDING PARTIAL AND COMPLETE PENETRATION
4 WOOD STRUCTURAL ELEMENTS AND ASSEMBLIES MUST BE SPECIAL
INSPECTED IN ACCORDANCE WITH SECTION 1704.2.5 SPECIAL INSPECTIONS
OF SITE-BUILT ASSEMBLIES.
A. PERIODIC INSPECTION:
1. WOOD STRUCTURAL PANEL SHEATHING GRADE AND THICKNESS
2. NOMINAL SIZE OF FRAMING MEMBERS AT ADJOINING PANEL EDGES
3. NAIL OR STAPLE DIAMETER AND LENGTH
4. NUMBER OF FASTENER LINES AND SPACING BETWEEN FASTENERS
IN EACH LINE AND AT EDGE MARGINS
5 POST-INSTALLED ANCHORS, INCLUDING BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS, AND LOW VELOCITY FASTENERS MUST BE
SPECIAL INSPECTED ACCORDING TO THE RELEVANT ANCHOR CODE
EVALUATION REPORTS.
A. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING THE INSTALLATION
OF POST-INSTALLED ANCHORS. SPECIAL INSPECTOR MUST VERIFY
THE FOLLOWING:
1. ANCHOR SIZE AND STEEL GRADE
2. HOLE DIAMETER, LOCATION AND TYPE OF DRILL BIT
3. COMPLIANCE WITH MANUFACTURER'S INSTRUCTIONS, INCLUDING HOLE
AND ANCHOR CLEANLINESS, AND ADHESIVE APPLICATON
4. ANCHOR EMBEDMENT DEPTH
6 SEE THE IBC AND OTHER DISCPLINE'S DRAWINGS FOR NON-STRUCTURAL
ITEMS REQUIRED TO BE SPECIAL INSPECTED.
SPECIAL INSPECTIONS
1 THE FOLLOWING MATERIALS MUST BE TESTED ACCORDING TO IBC SECTION
1705. ANY ITEMS FOUND TO BE DEFICIENT MUST BE CORRECTED AND
RE-TESTED AT NO ADDITIONAL COST TO THE GOVERNMENT.
2 CONCRETE STRENGTH VERIFICATION AND TESTING. ALL CONCRETE MUST
BE TESTED TO VERIFY STRENGTH, SLUMP, UNIT WEIGHT, AIR CONTENT AND
TEMPERATURE. SEE THE SPECIFICATIONS FOR TESTING CRITERIA,
FREQUENCY, AND ACCEPTABILITY CRITERIA.
3 STRUCTURAL STEEL: WELDED CONNECTIONS MUST BE TESTED FOR
COMPLIANCE WITH THE SPECIFICATIONS, AWS D1.1., AND THE CONTRACT
DOCUMENTS. MINIMUM TESTING MUST INCLUDE THE FOLLOWING:
A. ALL COMPLETE PENETRATION GROOVE WELDS MUST BE TESTED
ACCORDING TO METHODS DESCRIBED IN THE SPECIFICATIONS
B. A MINIMUM OF 50% OF PARTIAL PENETRATION GROOVE WELDS MUST BE
TESTING ACCORDING TO METHODS DESCRIBED IN THE SPECIFICATIONS.
C. ALL DEFICIENT WELDS MUST BE CORRECTED AND RE-TESTED AT
NO ADDITIONAL COST TO THE GOVERNMENT.
4 POST-INSTALLED ANCHORS, INCLUDING BUT NOT LIMITED TO EXPANSION
ANCHORS, ADHESIVE ANCHORS, AND LOW VELOCITY FASTENERS MUST BE
TESTED ACCORDING TO THE RELEVANT ANCHOR CODE EVALUATION
REPORTS.
5 SEE THE IBC AND OTHER DISCPLINE'S DRAWINGS FOR NON-STRUCTURAL
ITEMS REQUIRED TO BE TESTED.
STRUCTURAL TESTING
1 CONCRETE WORK MUST CONFORM TO THE REQUIREMENTS OF ACI 301-16,
"SPECIFICATION FOR STRUCTURAL CONCRETE BUILDINGS".
2 CONCRETE MUST BE NORMAL WEIGHT AND MUST OBTAIN A 28 DAY
COMPRESSIVE STRENGTH (UNLESS OTHERWISE NOTED):
CONCRETE MIN F'C (28 DAYS)
A. WALLS 5,000 PSI
B. SLABS ON GRADE 4,000 PSI
C. CONCRETE NOTE OTHERWISE NOTED 3,000 PSI
3 BEFORE PLACING CONCRETE, EMBEDDED ITEMS MUST BE PROPERLY
LOCATED, ACCURATELY POSITIONED, AND MAINTAINED SECURELY IN PLACE.
DO NOT FIELD BEND BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE
UNLESS INDICATED OR APPROVED BY THE CONTRACTING OFFICER.
4 EDGES OF PERMANENTLY EXPOSED CONCRETE SURFACES MUST BE
CHAMFERED 3/4" UNLESS OTHERWISE NOTED.
5 FORMWORK MUST REMAIN IN PLACE UNTIL CONCRETE HAS OBTAINED AT
LEAST 70% OF ITS 28 DAY COMPRESSIVE STRENGTH. THE CONTRACTOR MUST
PROVIDE ALL SHORING AND RESHORING.
6 SLAB FINISH TOLERANCE MUST BE IN ACCORDANCE WITH ACI 301, CLASS A.
FINISHES ARE SMOOTH RUBBED FINISH FOR EXPOSED CONCRETE WALL
SURFACES AND ANTI-SLIP TEXTURE FOR TOPPING SLAB SURFACES.
7 CONCRETE MUST BE MECHANICALLY VIBRATED IAW ASTM 309R.
8 CONSTRUCTION JOINTS (CJ) & SAWCUT JOINTS (SC) IN FLOOR SLABS MUST
OCCUR AS INDICATED ON DRAWINGS. CJ'S MUST HAVE FORMED POUR STOPS.
CJ'S IN WALLS & FOOTINGS NEED NOT OCCUR AT THE SAME LOCATION.
9 SLAB JOINTS MUST BE FILLED WITH AN APPROVED MATERIAL. THIS MUST TAKE
PLACE AS LATE AS POSSIBLE, PREFERABLY 4 TO 6 WEEKS AFTER THE SLAB AS
BEEN CAST. PRIOR TO FILLING, REMOVE ALL DEBRIS FROM THE SLAB JOINTS.
10 SLOPE EXTERIOR SLAB(S) TO DRAIN. COORDINATE WITH CIVIL DRAWINGS AT
LOCATIONS WHERE STRUCTURAL WORK REQUIRES DEMOLITION OF EXISTING
SITE ELEMENTS (SIDEWALKS, ETC) AND AT WORK COMPLETION, PATCHING OF
THOSE ELEMENTS TO MATCH ADJACENT. VERIFY GRADE CHANGES DO NOT
EXCEED 7" OR A CONCRETE STEP OR RAMP MUST BE PROVIDED.
11 ANCHOR RODS WITH UPSET THREADS ARE NOT ALLOWED.
12 AIR ENTRAINMENT IS REQUIRED PER PROJECT SPECIFICATIONS FOR THE
PERIMETER CURBING AND COLUMN PEDESTALS. HOWEVER IT IS NOT
REQUIRED, FOR THE FLOOR SLAB OVERLAY.
CAST-IN-PLACE CONCRETE NOTES
1 REINFORCING MATERIALS MUST BE AS FOLLOWS:
A. REINFORCING BARS – ASTM A615, GRADE 60, DEFORMED
B. TIES AND STIRRUPS – ASTM A615, GRADE 40
C. STAINLESS STEEL BARS, UON - ASTM A995, GRADE 60
D. WELDED WIRE FABRIC - ASTM A185, WELDED STEEL WIRE FABRIC,
SHEET TYPE, ROLL TYPE NOT ACCEPTABLE
2 UNLESS OTHERWISE NOTED, THE FOLLOWING MINIMUM CONCRETE COVER
MUST BE PROVIDED FOR CONCRETE PROTECTION OF REINFORCING, AS WELL
AS PLACING AND FABRICATION OF REINFORCING, IN ACCORDANCE WITH
RECOMMENDATIONS IN ACI 318:
A. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH = 3"
B. CONCRETE CAST IN FORMS AND EXPOSED TO EARTH OR WEATHER:
I. STRUCTURAL SLAB ON GRADE = 2”
II. #6 AND LARGER BARS = 2”
III. #5 BAR, W31 OR D31 WIRE & SMALLER = 1-1/2"
IV. COLUMNS, GIRDERS AND BEAMS = 1-1/2"
V. INTERIOR WALLS AND SLABS = 1-1/2"
3 SHOP DRAWINGS MUST BE SUBMITTED FOR REVIEW PRIOR TO FABRICATION
AND DELIVERY OF REINFORCING STEEL.
4 LAP CONTINUOUS REINFORCING STEEL A MINIMUM LENGTH OF:
A. CONCRETE - 36 X BAR DIAMETER OF SMALLER BAR BEING LAPPED
B. MASONRY - 48 X BAR DIAMETER OF SMALLER BAR BEING LAPPED
5 EACH REINFORCING BAR MUST BE WIRED TO A CROSS BAR AT A MAXIMUM
SPACING OF 2’-0” ON CENTER.
6 DETAIL BARS IN ACCORDANCE WITH ACI DETAILING MANUAL, LATEST EDITION.
PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCING IN
POSITIONS SHOWN. BAR SUPPORTS AND HOLDING BARS MUST BE PROVIDED
FOR ALL REINFORCING STEEL TO INSURE MINIMUM CONCRETE COVER. BAR
SUPPORTS MUST BE PLASTIC TIPPED OR STAINLESS STEEL.
7 USE OF POLYPROPYLENE FIBERS (IN LIEU OF WELDED WIRE FABRIC) IS
PROHIBITED.
8 PLACE REINFORCING STEEL IN ACCORDANCE WITH THE CONCRETE
REINFORCING STEEL INSTITUTE (CRSI) “MANUAL OF STANDARD PRACTICE”.
REINFORCING STEEL MUST NOT CONTAIN RUST, SCALE, OIL, GREASE, CLAY,
OR FOREIGN SUBSTANCES THAT WOULD REDUCE THE BOND. REMOVE
LOOSE RUST PRIOR TO PLACEMENT.
9 UNLESS OTHERWISE APPROVED, ALL WELDED WIRE FABRIC MUST BE
BLOCKED INTO THE POSITION INDICATED WITH PRECAST CONCRETE BLOCKS
HAVING A COMPRESSIVE STRENGTH EQUAL TO THAT OF THE SLAB (4,000 PSI).
10 ALL REINFORCING STEEL, DOWELS, ANCHORS RODS, AND OTHER HARDWARE
TO BE SET IN CONCRETE MUST BE TIED IN PLACE PRIOR TO THE PLACEMENT
OF CONCRETE TO PREVENT DISPLACEMENT BEYOND PERMITTED
TOLERANCES.
REINFORCING STEEL NOTES
SY
M
DE
S C
RI
PT
I O N
DA
TE
TOF X' - X"
X
TOP OF FOUNDATION
COLUMN GRID MARK
KEY NOTE
TOC X' - X" TOP OF CONCRETE
TOS X' - X" TOP OF STEEL X" TOP OF SLAB
SPOT ELEVATION
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
M
ID
-A
TL
AN
TI
C
N
AV
AL
S
TA
TI
O N
N
O R
FO
LK
, V A
AS NOTED
3/ 1/
:0
5:
A M
C :\R ev it
Lo ca l F ile s\
LA
G
-1
-S -R
_k im be rly .a
.d av is 2.
rv t
S-002
B U
IL
D
IN
G
L A
G -2
ST
RU
CT
UR
AL
N
O
TE
S -S
TE
EL
, T
IM
BE
R, A
NC
HO
RS
, S
YM
BO
LS
, L
EG
EN
D, AB
BR
EV
AI
TI
O
NS
DSG
12,862,942
KAD KAD
3/1/22
LT NINA R. ERB - USFFC
CO
M
PL
ET
E
BU
IL
DI
NG
R
EP
AI
R/
RE
NO
VA
TI
O
N
SEBASTIAN A. RAMOS, R.A.
1675989
N/A
NO
RF
OL
K, V
IR
GI
NI
A
NA
VA
L S
TA
TI
ON
N
OR
FO
LK
M
ID
LA
N T
PW
D
N O
R
FO
LK
S. M. SWEENEY, P.E.
N/A
13 EPOXY BONDING COMPOUND MUST CONFORM TO ASTM C881/C881M.
PROVIDE TYPE II FOR BONDING FRESHLY MIXED CONCRETE TO HARDENED
CONCRETE. PROVIDE GRADE 1 OR 2 FOR HORIZONTAL SURFACES AND
GRADE 3 FOR VERTICAL SURFACES. PROVIDE CLASS A IF PLACEMENT TEMP
IS <40 DEGREES F; CLASS B IF PLACEMENT TEMP IS BETWEEN 40 AND 60
DEGREES F; OR CLASS C IF PLACEMENT TEMP IS <60 DEGREES F. EPOXY
MUST DEVELOP A MINIMUM OF 12,650 PSI F’C (YIELD) AFTER 7 DAY CURE.
EPOXY MUST HAVE A HEAT DEFLECTION TEMPERATURE OF A MINIMUM OF
136 DEGREES FAHRENHEIT.
14 ANCHORS MUST HAVE BEEN SUCCESSFULLY TESTED IN ACCORDANCE WITH
ICC-ES ESR-4945 CRITERIA FOR WIND / SEISMIC LOADING, LONG-TERM
CREEP AT ELEVATED TEMPERATURES, AND STATIC LOADING AT ELEVATED
TEMPERATURES. ADHESIVE MUST BE EPOXY-TIE SET ADHESIVE FROM
SIMPSON STRONG-TIE, PLEASANTON, CA OR CONTRACTING OFFICER
APPROVED EQUIVALENT. ANCHORS MUST BE INSTALLED IN ACCORDANCE
WITH MANUFACTURER’S INSTRUCTIONS.
15 MECHANICAL SCREW ANCHORS MUST BE SCREW ANCHORS WITH 360
DEGREE CONTACT WITH THE BASE MATERIAL AND MUST NOT REQUIRE
OVERSIZED HOLES FOR INSTALLATION. FASTENERS MUST BE
MANUFACTURED FROM CARBON STEEL, AND MUST BE HEAT-TREATED.
ANCHORS MUST BE ZINC PLATED IN ACCORDANCE WITH ASTM B633 OR
MECHANICALLY GALVANIZED IN ACCORDANCE WITH ASTM B695. ANCHORS
ARE NOT TO BE RE-USED AFTER INITIAL INSTALLATION.
16 ANCHOR BAR MUST HAVE AN EMBEDMENT DEPTH AND HOLE DIAMETER
CAPACITY OF DEVELOPING 125% OF THE ANCHOR BAR ULTIMATE TENSILE
CAPACITY. ALL ANCHORAGE STRENGTH MUST BE BASED ON TESTING PER
ASTM E488, WITH ALLOWABLE LOADS NOT GREATER THAN 25% OF ULTIMATE
LOADS. ADHESIVE MATERIAL MUST COMPLY WITH AC308, “ACCEPTANCE
CRITERIA FOR POST-INSTALLED ADHESIVE ANCHORS IN CONCRETE
ELEMENTS”, ISSUED BY THE INTERNATIONAL CODE COUNCIL EVALUATION
SERVICE (ICC-ES). OTHER ADHESIVE TYPES WILL BE EVALUATED BASED ON
EQUIVALENT PERFORMANCE.
17 REBAR IS BELIEVED TO BE PRESENT IN THE EXISTING CONCRETE. PRIOR TO
DRILLING ANY HOLES, SCANNING TOOLS AND METHODS MUST BE USED TO
IDENTIFY THE LOCATION OF EXISTING REBAR. ADJUST ANCHOR POSITION
AS NECESSARY TO FACILITATE CORE DRILLING WHILE MAINTAINING MINIMUM
COVER REQUIREMENTS.
18 ANCHOR BAR HOLES MUST BE DRILLED TO A DEPTH AND DIAMETER AS
RECOMMENDED BY THE ADHESIVE MANUFACTURER, BUT NOT LESS THAN
4-INCH EMBEDMENT, UNLESS NOTED OTHERWISE.
19 EDGE DISTANCE FOR ADHESIVE BAR ANCHORS MUST BE 4-INCH MINIMUM.
1 ALL POST INSTALLED ANCHORS MUST BE SUITABLE AND INDEPENDENTLY
TESTED FOR USE IN CRACKED AND UNCRACKED CONCRETE.
2 ANCHOR CAPACITIES MUST BE DETERMINED PER AN INDEPENDENT TESTING
LABORATORY AND ANCHORS MUST MEET THE ASSESSMENT CRITERIA OF
ACI 355.2, ACI 355.4, OR HAVE AN ICC-ES EVALUATION REPORT INDICATING
CONFORMANCE WITH THE CONTRACT DOCUMENTS.
3 ANCHORS TO BE EXTERIOR TO THE STRUCTURE MUST BE HOT DIPPED
GALVANIZED PER ASTM A153 OR MECHANICALLY GALVANIZED.
4 INSTALLATION MUST BE PERFORMED BY PERSONNEL TRAINED TO INSTALL
POST INSTALLED ANCHORS IN ACCORDANCE WITH THE SPECIFICATIONS.
5 SPECIAL INSPECTOR MUST PERFORM PERIODIC SPECIAL INSPECTION OF
POST INSTALLED ANCHORS. WHERE ANCHORS ARE INSTALLED IN
HORIZONTAL OR UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED
TENSION LOADS, INSTALLATION MUST BE CONTINUOUSLY INSPECTED.
SPECIAL INSPECTOR MUST SUBMIT A REPORT OF ANCHORS FAILING
INSPECTIONS TO THE CONTRACTING OFFICER IN ACCORDANCE WITH THE
SPECIFICATIONS.
6 POST INSTALLED ANCHORS MUST BE PULL TESTED, IN ACCORDANCE WITH
THE SPECIFICATIONS. RESULTS MUST BE SUBMITTED TO THE ENGINEER OF
RECORD, THROUGH THE CONTRACTING OFFICER. ANCHORS THAT CANNOT
PHYSICALLY BE PULL TESTED, IN ACCORDANCE WITH THE SPECIFICATIONS,
MUST BE CONTINUOUSLY INSPECTED.
7 ADHESIVE ANCHOR BAR MUST CONSIST OF A REINFORCING BAR AND AN
INJECTABLE ADHESIVE CAPSULE(S).
8 WHEN PROVIDED IN NON-CAPSULE FORM, EPOXY ADHESIVE MUST BE
CONDITIONED, PROPORTIONED, MIXED AND APPLIED IN ACCORDANCE WITH
THE MANUFACTURERS RECOMMENDATIONS.
9 EXISTING REINFORCING MUST NOT BE DAMAGED DURING INSTALLATION OF
POST INSTALLED ANCHORS. ANY HOLES MADE FOR ANCHORS THAT ARE
NOT USED MUST BE FILLED WITH HIGH STRENGTH, NON-SHRINK,
NON-METALLIC EPOXY GROUT.
10 CHEMICAL ANCHORS MUST BE A TWO-COMPONENT, 100% SOLIDS EPOXY
BASED SYSTEM SUPPLIED IN MANUFACTURER’S STANDARD CARTRIDGE AND
DISPENSES THROUGH A STATIC-MIXING NOZZLE SUPPLIED BY THE
MANUFACTURER.
11 DRILL HOLES INTO THE EXISTING CONCRETE USING A ROTARY
(NON-HAMMERING) DRILL. HOLES MUST HAVE A ROUGHENED INTERIOR
SURFACE IN ACCORDANCE WITH ADHESIVE MANUFACTURER’S
RECOMMENDATIONS.
12 VACUUM DUST FROM THE BOTTOM AND SIDES OF EACH HOLE USING A
NOZZLE THAT WILL REACH THE BOTTOM OF THE HOLE. INSPECT EACH HOLE
WITH A LIGHT TO ENSURE THAT ALL DUST IS REMOVED.
POST-INSTALLED & ADHESIVE ANCHOR
NOTES (CONTINUED)
STRUCTURAL ABBREVIATIONS
L ANGLE
LB, LBS POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LONG LONGITUDINAL
MATL MATERIAL
MAX MAXIMUM
MD METAL DECK
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MOS MID-DEPTH OF SLAB
MPH MILES PER HOUR
NTS NOT TO SCALE
OC ON CENTER
OPH OPPOSITE HAND
PL PLATE
PLF POUNDS PER LINEAR
FOOT
PSF POUNDS PER SQUARE
FOOT
PSI POUNDS PER SQUARE
INCH
RE, REF REFERENCE
REINF REINFORCE, -MENT
REQD REQUIRED
SF SQUARE FEET
SIM SIMILAR
SPA SPACING
SPEC CONTRACT
SPECIFICATIONS
STD STANDARD
T&B TOP AND BOTTOM
THK THICKNESS
TOF TOP OF FOOTING
TOS TOP OF STEEL
TS THICKENED SLAB
TYP TYPICAL
UON UNLESS OTHERWISE
NOTED
VERT VERTICAL
W/, W/O WITH, WITHOUT
WWF WELDED WIRE FABRIC
~ , APPROX APPROXIMATELY
# NUMBER
& AND
@ AT
AFF ABOVE FINISHED FLOOR
ARCH ARCHITECT, -URAL
BLDG BUILDING
BOD BOTTOM OF DECK
BOT BOTTOM
BRCG BRACING
BRDG BRIDGING
C CHANNEL
CJ CONTROL JOINT
CL CENTER LINE
CLR CLEAR
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
DIA (OR) � DIAMETER
DIM(S) DIMENSION(S)
DWGS DRAWINGS
EA EACH
EF EACH FACE
EL ELEVATION
EQ, EQUIV EQUAL, EQUIVALENT
EW EACH WAY
EXIST EXISTING
F'C COMPRESSIVE STRESS
FDN FOUNDATION
FF EL FINISHED FLOOR
ELEVATION
FOS FACE OF SLAB
FTG FOOTING
FY ALLOWABLE YIELD
STRESS
HDG, GALV HOT DIPPED
GALVANIZED
HORIZ HORIZONTAL
HSS HOLLOW STRUCTURAL
SHAPES
IAW IN ACCORDANCE WITH
INFO INFORMATION
JBE JOIST BEARING
ELEVATION
KSI KILOPOUNDS (KIPS) PER
SQUARE INCH
PLAN LEGEND
STRUCTURAL SYMBOLS
COMPACTED SUBGRADE / FILL
CRUSHED STONE
MASONRY GROUT
CONCRETE
CONCRETE MASONRY UNIT
BRICK VENEER
METAL
WORKING POINT
7 STORE LUMBER AND PLYWOOD ON LEVEL RACKS AND KEEP FREE OF
GROUND TO AVOID WARPING. STACK TO INSURE PROPER VENTILATION AND
DRAINAGE.
8 PRESSURE TREAT ALL WOOD MEMBERS PERMANENTLY EXPOSED TO
WEATHER OR ANY WOOD IN CONTACT WITH CONCRETE OR MASONRY IN
ACCORDANCE WITH THE SPECIFICATIONS.
9 LIGHT GAUGE METAL FRAMING CONNECTORS MUST MEET THE
REQUIREMENTS OF ASTM A653, GRADE A (STRUCTURAL QUALITY). METAL
FRAMING CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD
MUST BE GALVANIZED IN ACCORDANCE WITH ASTM A653 WITH A G185
COATING.
10 WHERE MULTIPLE FRAMING MEMBERS ARE INDICATED, SCAB CONTINGENT
MEMBERS TOGETHER WITH 16d NAILS AT 12" ON CENTER, ALTERNATING AT 2
INCHES FROM EACH EDGE, UNLESS NOTED OTHERWISE.
11 FIT RIDGE AND EAVE JOINT MEMBERS FOR BEARING.
12 EXISTING WIRING, CONDUITS, AND DUCT WORK IS ATTACHED TO THE
EXISTING TIMBER FRAMING MEMBERS. ALL ABANDONED AND INACTIVE
WIRING, CONDUIT, AND/OR DUCTWORK IS TO BE DEMOLISHED. ALL ACTIVE
WIRING, CONDUIT, AND/OR DUCTWORK IN WAY OF WORK, IS TO BE
DETACHED FROM THE EXISTING FRAMING MEMBER(S) AND AFTER WORK IS
COMPLETED, RE-ATTACHED IN ACCORDANCE WITH THE MECHANICAL AND
ELECTRICAL DRAWINGS.
1 ROUGH CARPENTRY MUST COMPLY WITH THE NATIONAL FOREST
PRODUCTS ASSOCIATE (NFPA) "NATIONAL DESIGN SPECIFICATION FOR
WOOD CONSTRUCTION".
2 UNLESS NOTED OTHERWISE, ALL NAILING MUST BE IN ACCORDANCE WITH
THE "FASTENING SCHEDULE" SHOWN IN TABLE 2304.10.1 OF THE
INTERNATIONAL BUILDING CODE.
3 ALL WOOD FRAMING MUST MEET THE REQUIREMENTS OF DOC PS 20
"AMERICAN SOFTWOOD LUMBER STANDARD" AND THE FOLLOWING MINIMUM
REQUIREMENTS:
- MOISTURE CONTENT - SEASONED, WITH 19% MAXIMUM MOISTURE
CONTENT
- GRADE - NO.2 OR BETTER
- SPECIES - SOUTHERN PINE GRADED UNDER SPIB RULES
4 CONSTRUCTION PANELS MUST COMPLY WITH DOC PS1 "U.S. PRODUCT
STANDARD FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD" FOR PLYWOOD
CONSTRUCTION PANELS AND THE FOLLOWING:
- STRUCTURAL ROOF SHEATHING: 15/32 WOOD STRUCTURAL PANELS,
EXTERIOR GLUE, EXPOSURE 1 OR EXTERIOR
- DURABILITY CLASSIFICATION
5 STAGGER ALL END JOINTS FOR SHEATHING 4'-0". ALL END JOINTS MUST BE
MADE ON SUPPORTING MEMBERS.
6 ALL SHEATHING MUST BE NAILED AS FOLLOWS: ROOF SHEATHING - 10d
NAILS @ 4" O.C. EDGE NAILING AND 6" O.C. FIELD NAILING.
TIMBER NOTESLIGHT GAUGE STEEL FRAMING NOTESSTRUCTURAL STEEL NOTES
1 ALL STRUCTURAL STEEL MUST CONFORM TO THE FOURTEENTH EDITION OF
THE ALLOWABLE STRESS DESIGN "STEEL CONSTRUCTION MANUAL" OF THE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC).
2 UNLESS OTHERWISE NOTED, ALL MATERIALS MUST BE IN ACCORDANCE
WITH THE FOLLOWING ASTM SPECIFICATIONS:
MEMBER, ALL GALVANIZED ASTM MIN. STRENGTH
3 BOLTS AND NUTS MUST BE SHIPPED TOGETHER IN THE SAME SHIPPING
CONTAINER. FASTENER COMPONENTS MUST BE PROTECTED FROM DIRT
AND MOISTURE IN CLOSED CONTAINERS AT THE SITE OF THE INSTALLATION.
FASTENER COMPONENTS THAT ARE NOT INCORPORATED INTO THE WORK
MUST BE RETURNED TO PROTECTED STORAGE AT THE END OF THE WORK
SHIFT. BOLTS MAY BE TIGHTENED TO "SNUG TIGHT" CONDITION IN LIEU OF
FULL PRETENSIONING.
4 UNLESS OTHERWISE NOTED, ALL CONNECTIONS MUST BE AISC TYPE 2
“STANDARD FRAMED BEAM CONNECTIONS” WITH ASTM A307 BOLTS,
DESIGNED FOR THE UNIFORM LOAD CONSTANTS FOR LATERALLY
SUPPORTED BEAMS GIVEN IN THE “CONNECTIONS” SECTION OF THE
“MANUAL OF STEEL CONSTRUCTION”.
5 ALL STEEL (INCLUDING THOSE IN CONTACT WITH PRESSURE TREATED
WOOD) MUST BE HOT DIPPED GALVANIZED IN ACCORDANCE WITH ASTM
A153 OR A123 AS APPLICABLE WITH A G185 COATING. REPAIR DAMAGE TO
GALVANIZED COATINGS USING ASTM A780 ZINC RICH PAINT FOR
GALVANIZING DAMAGED BY HANDLING, TRANSPORTING, CUTTING, WELDING,
BOLTING, ETC. DO NOT HEAT SURFACES TO WHICH REPAIR PAINT HAS BEEN
APPLIED. ZINC RICH COMPOUND MUST BE 95% METALLIC ZINC, BY WEIGHT
IN DRIED FILM CONFORMING TO FED. SPEC. DOD-P-21035A AND MEETING MIL
SPEC. MIL-P-26915A. PROVIDE TWO COATS WITH 2 MIL THICKNESS PER
COAT FOR A TOTAL OF 4 MILS. GALVANIZE STRUCTURAL STEEL AFTER
FABRICATION WHERE PRACTICAL. FINAL FINISH MUST BE UNIFORM.
6 HARDENED STEEL SCREWS CANNOT BE HOT DIPPED GALVANIZED. USE
MANUFACTURER'S PRORPIETARY EPOXY COATING SYSTEM OR
MECHANICALLY GALVANIZED SUCH FASTERNERS IN ACCORDANCE WITH
ASTM B695, CLASS 55 OR C-3 MECHANICALLY GALVANIZED.
7 WELDING OF STRUCTURAL STEEL MUST BE IN ACCORDANCE WITH AWS D1.1
"STRUCTURAL WELDING CODE - STEEL". WELD ELECTRODES MUST BE
E70XX. UNLESS OTHERWISE NOTED, PROVIDE CONTINUOUS FILLET WELDS
WITH MINIMUM SIZE REQUIRED BY TABLE J2.4 OF THE “MANUAL OF STEEL
CONSTRUCTION, ALLOWABLE STRESS DESIGN”. ALL FILLER MATERIAL MUST
HAVE A MINIMUM YIELD STRENGTH OF 58 KSI.
8 PRIOR TO WELDING, THE CONTRACTOR MUST SUBMIT CERTIFICATION FOR
EACH WELDER STATING THE TYPE OF WELDING AND POSITIONS QUALIFIED
FOR, THE CODE AND PROCEDURE QUALIFIED UNDER, DATE QUALIFIED, AND
THE FIRM AND INDIVIDUAL CERTIFYING THE QUALIFICATION TESTS.
9 HOLES IN STEEL MUST BE DRILLED OR PUNCHED. BURNING OF HOLES AND
TORCH CUTTING AT THE SITE IS PROHIBITED.
10 SPLICING OF STEEL MEMBERS IS PROHIBITED.
11 USE LEVELING GROUT AS REQUIRED UNDER BASE PLATES TO A DEPTH OF
1". FILL WITH GROUT ANY HOLES, OPENINGS OR CRACKS WITHIN EXISTING
CONCRETE LEFT BY THE REMOVAL OF THE OLD. NON-SHRINK GROUT MUST
CONFORM TO ASTM C1107, WITH NO ASTM C827 SHRINKAGE (GROUT MUST
BE NONMETALLIC).
12 PROPRIETARY FRAMING CONNECTIONS MAY BE CONSIDERED FOR USE AT
THE CONTRACTORS OPTION AND EXPENSE. THE CONTRACTOR MUST
SUBMIT COMPLETE PRODUCT DATA FOR ALL COMPONENTS PRIOR TO
ORDERING MATERIALS.
13 COORDINATE WITH ARCHITECTURAL DRAWINGS FOR STEEL MEMBERS TO
RECEIVE PAINT AND PREPARE STEEL AS REQUIRED.
14 REFER TO DRAWINGS OF OTHER DISCPLINES FOR ADDITIONAL STEEL (IF
ANY) NOT SHOWN ON THE STRUCTURAL DRAWINGS.
15 UNLESS OTHERWISE NOTED, THE TOP & BOTTOM OF ALL EXTERIOR STEEL
COLUMNS OR OPEN ENDED STEEL BEAMS MUST HAVE A STEEL CAP PLATE.
UNLESS OTHERWISE DETAILED OR NOTED, MINIMUM CAP PLATE
DIMENSIONS MUST MATCH COLUMN WIDTH AND DEPTH AND MINIMUM
THICKNESS OF CAP PLATE MUST EQUAL COLUMN WEB THICKNESS (1/4"
MINIMUM).
MISC. ROLLED PLATES / SHAPES A36 36 KSI
CONNECTION BOLTS A307 (GRADE A)
NUTS A563 (GRADE TO MATCH BOLT)
WASHERS F436
ANCHOR BOLTS / THREADED
RODS
F1554 36 KSI
1 ALL COLD-FORMED STEEL FRAMING MEMBERS, THEIR DESIGN, FABRICATION,
AND ERECTION MUST CONFORM TO THE "SPECIFICATION FOR THE DESIGN OF
COLD-FORMED STEEL STRUCTURAL MEMBERS" OF THE AISI. THIS INCLUDES
STUDS, TRACKS, SECTIONS, SLIDE CLIPS, AND BRIDGING.
2 ALL FRAMING MEMBERS MUST BE FORMED FROM STEEL CONFORMING TO
ASTM A446 WITH A MINIMUM YIELD STRENGTH AS FOLLOWS:
A. 12, 14, 16 GAUGE MEMBERS FY=50 KSI (GRADE D)
B. 18, 20 GAUGE MEMBERS FY=33 KSI (GRADE A)
3 ALL FRAMING MEMBERS MUST BE GALVANIZED WITH A G-90 COATING
MEETING THE REQUIREMENTS OF ASTM A525.
4 GAUGE OF ALL TRACKS MUST BE NO LIGHTER THAN THE FRAMING BEING
CONNECTED.
5 ALL WELDING MUST BE IN CONFORMANCE WITH AMERICAN WELDING SOCIETY
SPECIFICATION D1.3. ALL WELDS MUST BE TOUCHED UP WITH ZINC RICH
PAINT.
6 ALL STRUCTURAL MEMBERS MUST BE PROPERLY CONNECTED TO EACH
OTHER AND TO THE SUPPORTING BACK-UP FRAMING. FASTENINGS MUST BE
MADE WITH SELF TAPPING SCREWS OR WELDS OF SUFFICIENT SIZE TO
INSURE THE CONNECTION STRENGTH. UNLESS OTHERWISE NOTED,
CONNECT ALL INTERIOR STUDS BASED ON A 10 PSF HORIZONTAL LOAD.
7 COMPONENTS ARE TO BE CUT SQUARELY FOR ATTACHMENT TO
PERPENDICULAR MEMBERS OR AS REQUIRED FOR AN ANGULAR FIT AGAINST
ABUTTING MEMBERS. FIELD CUTTING OF LIGHT GAUGE MEMBERS MUST BE
DONE BY SAWING OR SHEARING. TORCH CUTTING IS NOT ACCEPTABLE.
8 PROVIDE VERTICAL SLIDE TRACKS OR SLIDE CLIPS, WHERE INDICATED ON
THE DRAWINGS, TO ALLOW FOR VERTICAL STRUCTURAL MOVEMENTS.
MAXIMUM EXPECTED LIVE LOAD DEFLECTION IS L/240 AT ROOFS.
9 PROVIDE BRIDGING FOR STUDS AT MIDSPAN AND AT A MAXIMUM SPACING
NOT TO EXCEED 6'-0".
10 PROVIDE THE MANUFACTURER'S STANDARD TRACK, CLIP ANGLES, BRACING,
REINFORCEMENTS, FASTENERS AND ACCESSORIES AS RECOMMENDED BY
THE MANUFACTURER FOF THE APPLICATION INDICATED AND AS NEEDED TO
PROVIDE A COMPLETE FRAMING SYSTEM. UNLESS OTHERWISE NOTED,
INSTALL METAL FRAMING SYSTEM IN ACCORDANCE WITH THE
MANUFACURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS.
11 PIECE DESIGNATION NUMBERS, AS INDICATED ON DRAWINGS, ARE TAKEN
FROM STEEL STUD MANUFACTURER'S ASSOCIATION CATALOG
(WWW.SSMA.COM).
12 SEE ARCHITECTURAL DRAWINGS FOR NON-LOAD BEARING METAL STUD
PARTITIONS, REQUIRED SHEETING, FINISHES, INSULATION, AND THE
LOCATION OF ANY OPENINGS NOT SHOWN.
POST-INSTALLED & ADHESIVE ANCHOR
NOTES
TIMBER NOTES (CONTINUED)
SHORING / PHASING NOTES
1 CONTRACTOR MUST FINISH DEMOLITION WORK IN THE MEZZANINE
PRIOR TO STARTING DEMOLITION WORK OF SUPPORTING STUD
WALL BELOW.
2 IF CONTRACTOR ELECTS TO DO ALL COLUMN BASE REPAIRS AT THE
SAME TIME (AS COMPARED TO PHASING), THE BUILDING MUST BE
SHORED AGAINST UPLIFT AND SLIDING ACTION UNTIL THE COLUMN
REPAIRS ARE COMPLETED.
3 CONTRACTOR MUST SHORE THE EXISTING LONGITUDINAL
SPANDREL BEAMS DURING CONSTRUCTION, THE ENTIRE LENGTH OF
THE BEAM, UNTIL THE PERIMETER WALLS ARE COMPLETED.
SY
M
DE
S C
RI
PT
I O N
DA
TE
A
2 3 4 5 6 7 8 9
B
D
E
C
6"
9 1/2" ± 11' - 0 1/2" ± 10' - 10 1/2" ± 11' - 1 1/2" ± 10' - 11" ± 11' - 3" ± 10' - 10 1/2" ± 11' - 2" ± 15' - 11 1/2" ± 10 1/2" ±
5'
- 0
1/ 2"
2"
2"
5'
- 0 1/
2"
6x10 COL
12x12 COL
11x11 COL 6x10 COL 11x11 COL 6x10 COL
11x11 COL 11x11 COL
11x11 COL9.5X11 COL6x10 COL 11x11 COL9.5X11
COL6x10 COL12x12 COL 6x10 COL
11x11 COL
11x11 COL
4' - 8" ±
8'
- 0
1 3 /4"
4 3
/4"
8'
- 0
4' - 8" ±
94' - 10" ±
6"
SLOPE DOWN
SLOPE DOWN
6x10 COL
12x12 COL
3'
- 6
2'
- 0
A3 S-501
A3 S-501
A3 S-501
C1
SD501
- - - - - - - - - - - - - - - - - - - - - - - - - - - - C1
SD501
6x10 COL
10' - 6" ±
FO
R
2" D
EP
TH
AS
N
EE
DE
D
7' - 6" ±
8'
- 6
FOR 2" DEPTH
AS NEEDED
FOR DOOR
6' - 2 1/2" CURB DEMO 4' - 5 5/8" 3' - 2 1/2"
5' - 6 3/8"
15' - 4 7/8" CURB DEMO
6" C
UR
B
DE
MOC3
SD501
C3
SD501
SD901
SD901
3' - 0"
3'
- 0
SD901
A1
A2
SD901
A3
SD901
A4
SD901
A5
SD901
B5
UPWARDS
SD901
UPWARDS
B4