Attachment_A_-_List_of_Panels__Workstations__Pre-action__Dry_pipe.pdf

PDF 152 KB Posted

Attached to
Fire System and Suppression Maintenance and Repair Federal contract opportunity
Solicitation number
75N99025R00029
Issued by
Department of Health and Human Services National Institutes of Health Construction

About this file

The document is an equipment inventory list detailing fire system and suppression equipment across multiple buildings for the National Institute of Environmental Health Sciences. The inventory includes 18 fire annunciator nodes manufactured by Johnson Controls/SimplexGrinnell (primarily 4100es and 4100u models) located in various rooms and buildings, such as security offices, lobbies, mechanical rooms, and loading docks. Additionally, the list covers multiple fire suppression systems including Sapphire, Pre-Action, and Dry Pipe systems from manufacturers like Ansul, Grinnell, Reliable, Viking, and Tyco, positioned in locations like data centers, mechanical rooms, and dock areas.

The document systematically tracks equipment details with checkmarks indicating which services are covered under Task #1 (peripheral initiating devices, notification devices, panel components, batteries, and preventive maintenance) and Task #2 (fire suppression systems). Each equipment entry includes the equipment ID, manufacturer, model, and location, with "NA" markers for non-applicable items. The comprehensive inventory suggests a detailed maintenance contract for fire protection systems across multiple buildings, specifically for the NIEHS facility at Research Triangle Park, NC, with a focus on thorough documentation of existing fire safety infrastructure.

View the file

Other files for this federal contract opportunity

Other files attached to Fire System and Suppression Maintenance and Repair, newest first.
File Type Posted
Q_A_-_Solicitation_75N99025R00029_0002.pdf PDF
NIEHS_Sprinkler_Inspection_Report_0001_1.pdf PDF
NIEHS_Sprinkler_Inspection_Report_0001.pdf PDF
Sol_75N99025R00029.pdf PDF
Attachment_B_-_List_of_Points_associated_with_Fire_Panel.pdf PDF
Attachment_C__-_NFPA_25_Inspection_Table.pdf PDF
Attachment_E__-Invoice_instructions.pdf PDF
Attachment_D_-_Service_Contract_Wage_Determination.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Peripherial Initiating Devices Troubleshooting and Parts

COVERED UNDER TASK

#1 (smoke heads, heat detectors, flow switches, tamper switches, pull stations, IAMs, etc.)

Peripherial Notification Devices

Troubleshooting and Parts

COVERED UNDER

TASK #1

(horn, strobes, speakers, etc.)

Panel Components Troubleshooting and Parts

COVERED UNDER TASK

#1

(Power supplies, circuit boards, relays, modules, etc.)

Batteries

COVERED

UNDER

TASK #1

Preventive Maintenance, Testing and Inspections

COVERED UNDER

TASK #1

Fire Suppression Systems

COVERED UNDER

TASK #2

(suppresion piping, suppression heads, suppression valves, compressors)

Equipment ID Manufacturer Model Location (

Node 1 Johnson Controls/ SimplexGrinnell 4100es A & B Mod, Security Office

B114 NA

Node 2 Johnson Controls/ SimplexGrinnell 4100es C Mod, 1st Floor Elevator 3&4

Lobby

NA

Node 3 Johnson Controls/ SimplexGrinnell 4100es D Mod, 1st Floor Elevator

5&6 Lobby NA

Node 4 Johnson Controls/ SimplexGrinnell 4100es E Loading Dock Room E101 NA

Node 5 Johnson Controls/ SimplexGrinnell 4100es F Penthouse Electrical Room NA

Node 6 Johnson Controls/ SimplexGrinnell 4100es Building 102, Loading Dock

Mechanical Room S116Z NA

Node 7 Johnson Controls/ SimplexGrinnell 4100es Building 104, Loading Dock

Mechanical Room W108X NA

Node 8 Johnson Controls/ SimplexGrinnell 4100es Building 105, Room P124 NA

Node 9 Johnson Controls/ SimplexGrinnell 4100es Building 106, Room I102 NA

Node 10 Johnson Controls/ SimplexGrinnell 4100es Building 107, 10711 NA

Node 11 Johnson Controls/ SimplexGrinnell 4100es Building 108, Room 103 NA

Node 12 Johnson Controls/ SimplexGrinnell 4100es VCC Building 105,Security Office

P106B NA

Node 13 Johnson Controls/ SimplexGrinnell 4100u VCC B Mod, Security Office B114 NA

Node 14 Future Use Future Use Future Use NA

Node 15 Johnson Controls/ SimplexGrinnell TSW B Mod, Security Office B114 NA

Node 16 Johnson Controls/ SimplexGrinnell 4100u Building 109, Lobby NA

Node 17 Johnson Controls/ SimplexGrinnell 4100es Building 110, Print/Copy

Room NA

Node 18 Johnson Controls/ SimplexGrinnell TSW Building 105, Security Office

P106B NA

Sapphire Suppression System

Ansul Autopulse IQ-301 Bldg 104 Data Center

Pre-Action Suppression System

Grinnell 2" Grinnell F-517/TFP DV-5

Double Interlock Bldg 104 Mechanical Room NA NA NA

Pre-Action Suppression System

Reliable 2" Reliable DDX Double

Interlock Bldg 101/MRI/Mechanical Rm NA

Pre-Action Suppression System

Viking 2.5” Viking MOD. F-1 Deluge Valve Double Interlock Bldg 101/MRI/Mechanical Rm NA

Pre-Action Suppression System

Reliable 2" Reliable DDX Double

Interlock Bldg 110/Life Cycle Room NA NA

Dry Pipe System Tyco 2.5” Tyco DPV-1 Single Interlock Bldg 101/A Dock NA NA

Dry Pipe System Tyco 2.5” Tyco DPV-1 Single Interlock Bldg 101/C Dock NA NA

- Indicates these items are covered under the service contract.

- Indicates not covered under service contract.

NA- Not Applicable

Dry Pipe System Tyco 3” Tyco DPV-1 Single Interlock Bldg 101/E Dock NA NA Dry Pipe System Tyco 3” Tyco DPV-1 Single Interlock Bldg 102/103 Dock NA NA

Dry Pipe System Tyco 2.5” Tyco DPV-1 Single Interlock Bldg 105 Dock NA NA

Hood Suppression Ansul Bldg 101 Cafeteria NA NA Hood Suppression Ansul Bldg 101 Cafeteria NA NA