Attachment A - Exhibit A _ARCH Drawings~2.pdf
PDF 10 MB Posted
- Solicitation number
- S-KS0060-00018127
- Issued by
- Lane County, Oregon
About this file
This is an architectural drawing set and code compliance document for the City of Springfield's City Hall Deferred Maintenance and Quad Redesign Project located at 225 5th Street, Springfield, Oregon 97477. The project encompasses a comprehensive remodel of approximately 88,220 square feet across the main level, involving three distinct work areas: the North Quad, Southeast Quad, and Library (finishes only). The scope includes demolition, reconfiguration of existing spaces, new interior finishes, accessibility improvements, and updates to building systems including fire suppression, electrical, mechanical, and plumbing systems. The design development drawings are prepared at 75% completion for cost estimating purposes and are dated March 26, 2026, with architectural services provided by Rowell Brokaw Architects in Eugene, Oregon, structural engineering by Overstake Structural Solutions, and MEP engineering by Systems West, all under direction from the City of Springfield's Project Manager Jeff Paschall.
The project maintains the existing Type IIIB construction classification with a fully sprinklered system and does not propose changes to the building's occupancy classifications, which consist of Group A3 (Assembly) for the library and Group B (Business) for civic administration offices. Key project requirements include remodeling non-compliant restrooms to ADA standards, creating new ADA-compliant shower and changing rooms, installing new accessible service counters, and upgrading fire protection and life safety systems in accordance with the 2025 Oregon Structural Specialty Code, 2024 Oregon Fire Code, and 2023 Oregon Electrical and Plumbing Specialty Codes. The existing building is non-conforming relative to current area allowances; however, no occupancy or occupant load changes are proposed. Plumbing fixture requirements show 32 total water closets (including three urinals) and 24 total lavatories across assembly and business uses, with two drinking fountains (one new, one existing). The construction documents indicate this is a design development phase with full cost estimating, positioning the project for upcoming procurement and general contractor selection.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
WH
T
T
T T
AREA OF WORK:
N QUAD
AREA OF WORK:
SE QUAD
AREA OF WORK:
LIBRARY (FINISHES ONLY)
DRAWING SYMBOLS KEY AND ABBREVIATIONS
A-101
SIM
XXX
1 XX
NORTH: IN DIRECTION OF ARROW HEAD
ELEVATION MARKER
SPOT ELEVATION MARKER
SECTION CALLOUT:
ARROW INDICATES DIRECTION OF SECTION VIEW
- SOLID ARROW - BUILDING SECTION
- OPEN ARROW - DETAIL SECTION
ROOM NAME
ROOM # ROOM TAG
SIM OR TYP
DESIGNATION
SECTION OR DETAIL #
SHEET #
SIM OR TYP
DESIGNATION
SECTION OR DETAIL
SHEET #
DETAIL CALLOUT
KEYNOTE TAG:
SEE KEYNOTE LEGEND PER SHEET
GRIDLINE MARKER
INTERIOR ELEVATION CALLOUT:
NUMBERS AT ARROWS INDICATE
REFERENCED ELEVATION DRAWINGS
ELEVATION #
SHEET #
WALL TAG -
SEE SHEET A-002 FOR MORE INFORMATION
FLOOR TAG
EXTERIOR WALL TAG
WINDOW/STOREFRONT TAG
A-2
EXTERIOR ELEVATION CALLOUT:
NUMBERS AT ARROWS INDICATE REFERENCED
ELEVATION DRAWINGS
A 011
CEILING ASSEMBLY TAG
ROOF TAG
ELEVATION #
SHEET #
CASEWORK TYPE TAG:
SEE DETAIL SHEET FOR ADDITIONAL INFO.
EQUIPMENT / TOILET ACCESSORIES TAG
A
C1-A
R1
F1
EW1
##A
W1
WINDOW TAG:
WINDOW TYPE AND ID #
W1
A-1 01Ref
101-1 DOOR TAG
XX1
Room Name
CABINET TYPE
CABINET DEPTH
A-101
SIM
T
H S
T R
E E
T
NORTH "A" STREET
BOOK DROP
FIRE PANEL /
RISER ROOM
MECH
STOR
BIKE /
STOR.
T
T
(4) BIKE RACKS, (E)
(13) BIKE RACKS, (E)
(4) BIKE RACKS, (E)
(2) BIKE RACKS, (E)
MAIN LEVEL PERIMETER, ABOVE
NOTE: NO CHANGES ARE PROPOSED TO
GROUND LEVEL / SITE. ALL ELEMENTS
ARE SHOWN FOR GENERAL CONTEXTUAL
INFORMATION ONLY - LOCATIONS AND
QUANTITIES ARE APPROXIMATE.
OPEN TO
ABOVE
ELEV
ELEV
MECH
PROJECT LOCATION
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:1
P
M
G-001
COVER
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
DRAWING INDEX
Sheet Number Sheet Name
00-GENERAL
G-001 COVER
G-002 CODE SUMMARY
G-003 CODE PLAN - MAIN FLOOR
G-004 ACCESSIBILITY - PUBLIC SPACES
G-005 ACCESSIBILE ROUTE - DOORS - CLEARANCES
03-ARCHITECTURAL
A-001 ASSEMBLIES
D-101 DEMO PLAN - OVERALL
D-102 DEMO RCP - OVERALL
A-110 MAIN LEVEL PLAN - OVERALL
A-111 ROOF PLAN - OVERALL
A-120-N DIMENSION PLAN - NORTH
A-121-SE DIMENSION PLAN - SOUTHEAST
A-141-N REFLECTED CEILING PLAN - NORTH
A-142-SE REFLECTED CEILING PLAN - SOUTHEAST
A-201 BUILDING ELEVATIONS
A-210 BUILDING SECTIONS
A-330 EXTERIOR DETAILS
A-402-N ENLARGED PLAN & ELEVATIONS - NORTH - RESTROOMS
A-403-SE ENLARGED PLANS & ELEVATIONS - LOCKER ROOMS - SOUTHEAST
A-501 DOORS & WINDOWS
A-601-N INTERIOR ELEVATIONS - NORTH CORE
A-602-NW INTERIOR ELEVATIONS - NORTH WEST
A-603-NE INTERIOR ELEVATIONS - NORTH EAST
A-604-SE INTERIOR ELEVATIONS - SOUTHEAST- AMENITIES
A-605-SE INTERIOR ELEVATIONS - SOUTHEAST - FACILITIES AND AMENITIES
A-606-SE INTERIOR ELEVATIONS - SOUTHEAST - HR & IT/FINANCE
A-620 INTERIOR DETAILS - MISC
A-621 INTERIOR DETAILS - CEILINGS
A-622 INTERIOR DETAILS - CASEWORK
A-623 INTERIOR DETAILS - CASEWORK
A-701-N FINISH PLAN - NORTH
A-702-SE FINISH PLAN - SOUTHEAST
A-703-SW FINISH PLAN - LIBRARY - SOUTHWEST
A-704 FINISH SCHEDULE
A-705-N FURNITURE PLAN - NORTH
A-706-SE FURNITURE PLAN - SOUTHEAST
SPRINGFIELD QUAD REMODEL
OWNER
75%CD / COST ESTIMATING SET
MECHANICAL, ELECTRICAL & PLUMBING ENGINEERSGENERAL CONTRACTOR - TBD
ROWELL BROKAW ARCHITECTS
1203 WILLAMETTE STREET, SUITE 210
EUGENE, OR 97401
PH: 541-485-1003
CONTACTS:
BRITNI JESSUP
britni@rowellbrokaw.com
KARA STRICKLAND
kara.strickland@rowellbrokaw.com
ARCHITECT
SYSTEMS WEST
725 A St Springfield, OR 97477
PH: 541-342-7210
CONTACT:
CHARLIE WHITE
cwhite@systemswestengineers.com
CITY OF SPRINGFIELD
225 5TH ST
SPRINGFIELD, OR 97477
PH: 541-726-1674
CONTACT:
JEFF PASCHALL
jpaschall@springfield-or.gov
1/64" = 1'-0" | Ref: 1 / A-201G-001
1 AREA OF WORK - 2ND FLOOR
STRUCTURAL ENGINEER
Overstake Structural Solutions 2852 Willamette St Eugene, OR 97405
PH: 541-780-4019
CONTACT:
BRIAN OVERSTAKE
brian@ostructural.com
& AND
@ AT
ACM COMPOSITE METAL PANEL
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AV AUDIO / VISUAL
BD BOARD
BLW BELOW
BO BOTTOM OF
BOC BOTTOM OF CONCRETE
BOS BOTTOM OF SLAB
BOT, BOTT BOTTOM
BR BRICK
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COE CITY OF EUGENE (BUILDING DEPARTMENT)
COL COLUMN
COMP COMPENSATING
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CW CURTAIN WALL
DBL DOUBLE
DEPR DEPRESSION
DIA DIAMETER
DIM DIMENSION
DJ DRIFT JOINT
DS DOWN SPOUT
DTL DETAIL
DW DISHWASHER
DWG DRAWING
DWR DRAWER
(E) EXISTING
ELEV ELEVATION
ELEV ELEVATOR
ENC ENCLOSURE
ENT ENTRY
EQ EQUAL
ES EXTERIOR STOREFRONT
FAC FACTORY
FC FAN COIL
FCS FIBER CEMENT SIDING
FD FLOOR DRAIN
FDC FIRE DEPARTMENT CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FLR, FL FLOOR
FND FOUNDATION
FO FACE OF
FOF FACE OF FINISH
FR FIRE RATED
FRMG FRAMING
FRP FIBER REINFORCED PLASTIC
FS FIRE SPRINKLER
GF GROUND FLOOR
GL GLAZING
GL GRIDLINE
GWB GYPSUM WALL BOARD
HGT HEIGHT
HM HOLLOW METAL
HNDRL HANDRAIL
HR HOUR
HS HOLLOW STEEL
INSUL INSULATION
IS INTERIOR STOREFRONT
LCKR LOCKER
LOC LOCATION
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MEMB MEMBRANE
MFR MANUFACTURER
MIN MINIMUM
MIR MIRRORED
(N) NEW
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NTS NOT TO SCALE
O/ OVER
OC ON CENTER
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OFOI OWNER FURNISHED OWNER INSTALLED
OPNG OPENING
OPP OPPOSITE
PLAM PLASTIC LAMINATE
PTD PAINTED
RCB RUBBER COVE BASE
RCP REFLECTED CEILING PLAN
REF REFRIGERATOR
REINF REINFORCING
REQ REQUIRED
RO ROUGH OPENING
SAM SELF-ADHERING MEMBRANE
SD STORM DRAIN
SF SQUARE FEET
SFRM SPRAYED FIRE-RESISTIVE MATERIAL
SHWR SHOWER
SIM SIMILAR
SPEC SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STFT STOREFRONT
STL STEEL
STRUC STRUCTURE
SUSP SUSPENDED
T.O. TOP OF
TBD TO BE DETERMINED
TOC TOP OF CONCRETE
TOF TOP OF FOOTING
TOS TOP OF SLAB
TWF THROUGH WALL FLASHING
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
W/ WITH
W/I WITHIN
W/O WITHOUT
WA WALL ASSEMBLY
WH WATER HEATER
WP WATER PROOFING
WRB WEATHER RESISTANT BARRIER
| 2 / A-XXX
NORTH ARROW
VIEW #
SHEET #
DRAWING SCALE
REFERENCING
VIEW & SHEET #
3" = 1'-0"G-001
3 VIEW TITLE LEGEND
1" = 40'-0" | Ref: 1 / A-201G-001
4 GROUND LEVEL PLAN - EXISTING
N.T.S.
VICINITY MAP
Attachment A - Exhibit A
REF REFMWMW
4A 5 61 2 3 7 8 10 129 114
13 14 15 16 1817
A
B
C
D
F
H
M
L
K
J
I
G
E
4'
8'
/2
E X
IT
S
E P
A R
A T
IO
N
MULTI-PURPOSE RM DIAGONAL
± 82' - 3"
21' - 4"
NE.1
163' - 7"
NE.2
NORTH Q
UAD DIAGONAL
± 215' - 11"
'/2
EXIT
S
EPARATIO
N
1'
- 1
1"
142' - 3"
NW
STACKS:
8,226 SF / 100 OLF =
83 OCCUPANTS
READING ROOM:
10,633 SF / 50 OLF =
213 OCCUPANTS
NON-CONCENTRATED
ASSEMBLY (MTG RM):
1,448 SF / 15 OLF =
97 OCCUPANTS
BUSINESS
(OFFICES & RECEPTION):
4,968 SF / 150 OLF =
34 OCCUPANTS
ACCESSORY - MEP:
215 SF / 300 OLF =
1 OCCUPANTS
LIBRARY TOTAL:
428 OCCUPANTS
LIBRARY OCC. LOADS
BUSINESS:
20,113 SF / 150 OLF =
135 OCCUPANTS
ACCESSORY - MEP:
383 SF / 300 OLF =
2 OCCUPANTS
NORTH QUAD TOTAL:
137 OCCUPANTS
NORTH QUAD OCCUPANCY LOADS
ASSEMBLY, NON-CONCENTRATED
(ACCESSORY TO BUSINESS OCCUPANCY)
2,158 SF / 15 OLF=
144 OCCUPANTS
MULTI-PURPOSE RM
ASSEMBLY - NON CONCENTRATED:
1,247 SF / 15 OLF =
84 OCCUPANTS
SEATING AREA OCC LOAD
ASSEMBLY - CONCENTRATED (NOT FIXED):
1,417 SF / 7 OLF=
203 OCCUPANTS
COUNCIL CHAMBER (SEATING AREA)
(NOT INCLUDING MULTI-
PURPOSE RM)
BUSINESS:
7,961 SF / 150 OLF=
54 OCCUPANTS
EXERCISE + LOCKER ROOMS:
2,483 SF / 50 OLF=
50 OCCUPANTS
ACCESSORY - MEP:
273 SF / 300 OLF=
1 OCCUPANT
SE QUAD TOTAL:
105 OCCUPANTS
SOUTHEAST QUAD OCC LOADS
2ND FLOOR TOTAL: 1,250 OCCUPANTS
BUSINESS:
22,201 SF / 150 OLF=
149 OCCUPANTS
CITY HALL (MISC.) OCC LOADS
123' - 4"
SE-IT.2
22' - 7"
SE-IT.1
45' - 0"
SE-MP.1
172' - 1"
SE-MP.2
58' - 9"
SE-LR.1
235' - 4"
SE-LR.2
FEC
FEC
FEC
FEC
69' - 7"
FEC
69' - 7"
FEC
FEC
59' - 7"
FEC
LIBRARY
LIBRARY MTG
GYM
254.A
SE - IT / FINANCE
SE - HR SUITE
MULTI - PURPOSE
252.A
MEETING
CENTRAL CORRIDOR
NE QUAD
NW QUAD
CONF.
CONF.
KITCHEN
224.A
ELECTRICAL
224.C
TEL
SPRINKLER
SERVER
QUIET
224.B SOUND BOOTH
COUNTER LOBBY
201.A
CONF.
PRINT & SUPPLY
STORAGE
FACILITIES
250.A
CONF.
ELECTRIC
RADIO
ALT. COMMUTE
259.B
CUSTODIAL
QUIET
SECURITY
250.C
OFFICE
250.B
STORAGE
STORAGE
CUSTODIAL
WOMEN
211.B
MEN
211.C
HALL
MUD RM
MEN
223.A
WOMEN
223.B
MEETING
COUNCIL CHAMBER
EXISTING CLINIC
72' - 5"
FEC
FEC
48' - 8"
FEC
LIBRARY OFFICES
CENTRAL CORRIDOR
CENTRAL CORRIDOR
OPEN
COMMON PATH OF TRAVEL (1006.2.1)
AREA(S) OF SCOPE
PATH OF TRAVEL
A-3 ASSEMBLY OCCUPANCY
B BUSINESS OCCUPANCY
CODE PLAN LEGEND
FEC
FIRE EXTINGUISHER CABINET
TYPE: XXX
EXIT SIGN
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:1
P
M
G-003
CODE PLAN - MAIN
FLOOR
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/16" = 1'-0"G-003
1 CODE PLAN - MAIN FLOOR - OVERALL
CODE SUMMARY
CHAPTER 1: ADMINISTRATION
CHAPTER 3: USE AND OCCUPANCY CLASSIFICATION
NO CHANGES PROPOSED TO EXISTING BUILDING USE AND OCCUPANCY.
OCCUPANCY PER SECTION 304:
GROUP A3 (ASSEMBLY) - LIBRARY
GROUP B (BUSINESS) - CIVIC ADMINISTRATION OFFICES
CHAPTER 5: GENERAL BUILDING HEIGHTS AND AREAS
ALLOWABLE HEIGHT AND STORIES:
TABLES 504.3 AND 504.4 - TYPE IIIB, FULLY SPRINKLERED:
GROUP A3:
MAXIMUM: 75 FT HEIGHT, 3 STORIES
ACTUALS: 23.5 FT HEIGHT, 2 STORIES
GROUP B:
MAXIMUMS: 75 FT HEIGHT, 4 STORIES
ACTUALS: 23.5 FT HEIGHT, 2 STORIES
ALLOWABLE AREA DETERMINATION:
TABLE 506.2 - TYPE IIIB, FULLY SPRINKLERED:
GROUP A3: 28,500 SF
GROUP B: 57,000 SF
PROPOSED BUILDING AREA, MAIN LEVEL (GSF):
OCCUPANCY EXISTING PROPOSED ALLOWED
A3 ±25,725 NO CHANGE 28,500
B ±62,495 NO CHANGE 57,000
TOTAL: ±88,220 NO CHANGE 85,500
EXISTING BUILDING IS NON-CONFORMING.
SECTION 506.3 FRONTAGE INCREASE: NO CHANGES PROPOSED.
SECTION 508 MIXED USE AND OCCUPANCY:
BUILDING IS MIXED OCCUPANCY ON MAIN LEVEL.
508.2 ACCESSORY A3 OCCUPANCIES:
MULTI-PURPOSE ROOM: 2,158 SF
NONCONCENTRATED SEATING AREA: 1,247 SF
508.2.3 ACCESSORY OCCUPANCIES CANNOT BE MORE THAN 10% OF AREA OF STORY
THEY ARE IN.
A3 - ACCESSORY TO GROUP B: 3,405 SF
B - ACCESSORY TO GROUP A3: 3,800 SF
AGGREGATE TOTAL: (7,205 SF / 88,220 SF) 100 = 8.2%
508.2.4 ACCESSORY OCCUPANCIES NEED NO SEPARATION TO MAIN OCCUPANCY.
508.3 NONSEPARATED OCCUPANCIES:
508.3.2 ALLOWABLE BUILDING AREA, HEIGHT AND NUMBER OF STORIES - THE
BUILDING OR PORTION THEREOF SHALL BE BASED ON THE MOST RESTRICTIVE
ALLOWANCES FOR THE OCCUPANCY GROUPS UNDER CONSIDERATION FOR THE
TYPE OF CONSTRUCTION OF THE BUILDING IN ACCORDANCE WITH SECTION 503.1.
EXISTING BUILDING IS NON-CONFORMING.
509 INCIDENTAL USES - ELECTRICAL ROOMS MUST COMPLY WITH SECTIONS 110.26
THROUGH 110.34 OF THE ELECTRICAL CODE.
CHAPTER 7: FIRE AND SMOKE PROTECTION SYSTEMS
SECTION 704.1 AND 707.5
NO CHANGES PROPOSED.
SECTION 705 EXTERIOR WALLS
TABLE 705.5 - FIRE-RESISTANCE RATINGS FOR EXTERIOR WALLS BASED ON FIRE
SEPARATION DISTANCE
GROUP A, B - TYPE IIIB CONSTRUCTION:
DIST. TO NEAREST LOT LINE/ CL ROW FIRE-RATING
NORTH ELEVATION: 5.5' NO CHANGES - N/A
EAST ELEVATION, NORTH QUAD: 6.2' 1 HOUR
EAST ELEVATION, SOUTH QUAD: 5.3' (VFY) 1 HOUR
SOUTH ELEVATION: 12.4' NO CHANGES - N/A
NORTH-WEST ELEVATION: 3.4' NO CHANGES - N/A
SOUTH-WEST ELEVATION: 4.9' NO CHANGES - N/A
SECTION 705.9 OPENINGS
APPLICABLE TO TOTAL WALL/OPENING AREA INCLUDING PROPOSED NEW WINDOW
OPENINGS IN 1-HR RATED EXTERIOR WALLS.
TABLE 705.9 - MAXIMUM AREA OF OPENINGS BASED ON FIRE SEPARATION DISTANCE
OF 5 TO LESS THAN 10 FEET:
EAST ELEVATION, NORTH QUAD - UNPROTECTED, SPRINKLERED: 25%
EAST ELEVATION, SOUTH QUAD - UNPROTECTED, SPRINKLERED: 25%
SECTION 706 FIRE WALLS
NO CHANGES PROPOSED.
SECTION 707 FIRE BARRIERS
708.4 SHAFT ENCLOSURES - NO CHANGES PROPOSED.
1022.2 EXIT ENCLOSURES - NO CHANGES PROPOSED.
707.4 EXTERIOR WALLS OF SHAFT/EXIT ENCLOSURE: NO CHANGES PROPOSED.
707.6 CONTINUITY - NO CHANGES PROPOSED TO EXTENT OF EXISTING FIRE-RATED
EXTERIOR WALLS.
SECTION 708 FIRE PARTITIONS
TABLE 1020.2 - CORRIDOR WALLS NOT REQUIRED TO BE RATED IN FULLY
SPRINKLERED BUILDING OF A AND B GROUP OCCUPANCY.
SECTION 711 FLOOR AND ROOF ASSEMBLIES
NO CHANGES PROPOSED.
SECTION 716 OPENING PROTECTIONS
NOT REQUIRED WHERE TOTAL OPENING AREA IS LESS THAN 25% OF FIRE-RATED
EXTERIOR WALL AREA PER 705.9.
SECTION 718 CONCEALED SPACES
718.4 DRAFTSTOPS NOT REQUIRED IN FULLY SPRINKLERED BUILDINGS.
EXISTING DRAFTSTOPS TO REMAIN WHEREVER POSSIBLE DURING INSTALLATION OF
PROPOSED NEW BUILDING SYSTEMS.
SECTION 720 THERMAL AND SOUND INSULATING MATERIALS
CONCEALED BATT INSULATION TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN
25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450.
CHAPTER 8: INTERIOR FINISHES
SECTION 803 - WALL AND CEILING FINISHES
TABLE 803.13 - INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY
GROUP B, SPRINKLERED:
CORRIDORS - CLASS C
ROOMS & ENCLOSED SPACES - CLASS C
GROUP A3, SPRINKLERED:
CORRIDORS - CLASS B
ROOMS AND ENCLOSED SPACES - CLASS C
SECTION 804 FLOORS
INCLUDES FIBER MATERIAL ONLY - CLASS I OR CLASS II
SECTION 806 DECORATIVE MATERIALS AND TRIM
IN GROUP A AND B, DECORATIVE MATERIALS MEETING NFPA701 MUST NOT EXCEED
10% OF WALL OR CEILING TO WHICH THEY ARE ATTACHED, OR MUST BE NON-
COMBUSTIBLE.
SECTION 808 ACOUSTICAL CEILING SYSTEMS
INSTALL SUSPENDED ACOUSTICAL CEILINGS IN ACCORDANCE WITH ASTM C635 AND
C636. IF USED IN A FIRE RATED ASSEMBLY, MUST BE INSTALLED PER TESTED
ASSEMBLY AND SHALL COMPLY WITH CHAPTER 7.
CHAPTER 9: FIRE PROTECTION SYSTEMS
SECTION 903 AUTOMATIC SPRINKLER SYSTEM
EXISTING BUILDING IS FULLY SPRINKLERED. WHERE WALL RECONFIGURATIONS ARE
PROPOSED IN GROUP B - OFFICE AREAS, THE EXISTING SPRINKLER SYSTEM WILL BE
MODIFIED TO PROVIDE ADEQUATE FIRE SUPPRESSION COVERAGE. ALL NEW AND
MODIFIED SPRINKLER SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH NFPA13.
SECTION 906 PORTABLE FIRE EXTINGUISHERS - TO COMPLY W/ OFC 906.
SECTION 907 ALARM AND DETECTION:
NO CHANGES PROPOSED TO EXISTING ALARM AND DETECTION SYSTEMS, EXCEPT AS
REQUIRED BY CODE IN RECONFIGURED GROUP B - OFFICE AREAS. ALL NEW OR
MODIFIED SYSTEMS TO BE INSTALLED IN ACCORDANCE WITH OSSC 2025 AND NFPA
72.
907.2.1 GROUP A
EXCEPTION 1 - MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE
BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM
INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT
NOTIFICATION APPLIANCES WILL ACTIVATE THROUGHOUT THE NOTIFICATION
ZONES UPON SPRINKLER WATER FLOW.
907.2.2 GROUP B
EXCEPTION - MANUAL FIRE ALARM BOXES ARE NOT REQUIRED WHERE THE
BUILDING IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM
INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.1 AND THE OCCUPANT
NOTIFICATION APPLIANCES WILL ACTIVATE THROUGHOUT THE NOTIFICATION
ZONES UPON SPRINKLER WATER FLOW.
SECTION 912 FIRE DEPARTMENT CONNECTIONS:
NO CHANGES PROPOSED.
CHAPTER 6: TYPES OF CONSTRUCTION
CONSTRUCTION TYPE: TYPE IIIB
FIRE RESISTANCE OF BUILDING ELEMENTS, TABLE 601:
EXTERIOR WALLS: 1 HR
ALL OTHER ELEMENTS: 0 HR
SECTION 602.3 - TYPE III: EXTERIOR WALLS ARE OF NONCOMBUSTIBLE MATERIALS AND
THE INTERIOR BUILDING ELEMENTS ARE A MIX OF WOOD, STEEL, AND
CONCRETE/MASONRY MATERIALS.
CHAPTER11: ACCESSIBILITY
ALTERATIONS OF EXISTING BUILDINGS TO INCLUDE IMPROVEMENTS TO
ACCESSIBILITY COSTING UP TO 25% OF PROJECT BUDGET.
PROPOSED IMPROVEMENTS INCLUDE:
• REMODEL EXISTING NON-COMPLIANT RESTROOMS TO COMPLY W/ ADA
STANDARDS.
• NEW ADA-COMPLIANT SHOWER ROOMS AND CHANGING ROOMS PROVIDED.
• NEW ACCESSIBLE SERVICE COUNTER.
TOTAL ESTIMATED COST OF IMPROVEMENTS: TBD
PERCENT OF ESTIMATED PROJECT BUDGET: TBD
CHAPTER 29: PLUMBING SYSTEMS
TABLE 2902.1: MINIMUM NUMBER OF REQUIRED PLUMBING FIXTURES:
MAIN FLOOR, MIX OF ASSEMBLY AND BUSINESS USES:
FIXTURE TYPE REQUIRED PROPOSED (EXISTING+NEW)
WATER CLOSETS 23 TOTAL 32 TOTAL, INCLUDES 3 URINALS
ASSEMBLY 7W / 4M
BUSINESS 6W / 6M
LAVATORIES 12 TOTAL 24 TOTAL
ASSEMBLY 6 W/M
BUSINESS 6 W/M
DRINKING FOUNTAINS 1 TOTAL 2 TOTAL - (1) NEW, (1) EXISTING
SECTION 1004 OCCUPANT LOAD
OCCUPANT LOADS HAVE BEEN APPLIED ACCORDING TO OSSC 2025.
SEE CODE PLANS FOR USE OF INDIVIDUAL SPACES AS WELL AS OCCUPANT LOADS.
OCCUPANT LOAD CRITERIA:
TABLE 1004.5
FUNCTION OF SPACE SF/OCCUPANT
BUSINESS/OFFICE 150 GROSS
MEETING/CONF RM 15 NET
MULTI-PURPOSE RM 15 NET
EXERCISE RM 15 NET
COUNCIL CHAMBER 7 NET
LIBRARY - STACKS 100 GROSS
LIBRARY - READING RM 50 NET
MECH 300 GROSS
STORAGE 300 GROSS
1004.8 OUTDOOR AREAS
NO CHANGES PROPOSED.
SECTION 1005 EGRESS WIDTH
NO CHANGES PROPOSED - SEE CODE PLANS.
SECTION 1006 NUMBER OF EXITS AND EXIT ACCESS DOORWAYS
TABLE 1006.2.1 - TWO EXITS OR EXIT ACCESS DOORWAYS REQUIRED WHERE
OCCUPANT LOAD OR COMMON PATH OF EGRESS TRAVEL EXCEEDS:
GROUP A, SPRINKLERED: 75' -OR- MAX OCC LOAD: 49
GROUP B, SPRINKLERED: 100' -OR- MAX OCC LOAD: 49
SECTION 1010 DOORS
1010.2.8 PANIC HARDWARE REQUIRED IN SPACES WITH AN OCCUPANT LOAD OF 50 OR
MORE.
1010.4 GATES SHALL CONFORM TO THE APPLICABLE REQUIREMENTS FOR DOORS.
SECTION 1011 STAIRWAYS
NO CHANGES PROPOSED.
SECTION 1016 EXIT ACCESS
1016.2 EGRESS THROUGH INTERVENING SPACES ALLOWED WHERE ADJOINING SPACES
ARE ACCESSORY TO EACH OTHER AND PROVIDE A DISCERNIBLE PATH OF EGRESS
TRAVEL TO AN EXIT.
SECTION 1017 EXIT ACCESS TRAVEL DISTANCE
TABLE 1017.2
GROUP A, SPRINKLERED: 250'
GROUP B, SPRINKLERED: 300'
SECTION 1019 EXIT ACCESS STAIRWAYS:
NO CHANGES PROPOSED - SEE CODE PLAN.
SECTION 1020 CORRIDORS
TABLE 1020.2 CONSTRUCTION
OCCUPANCY GROUP A, B - FULLY SPRINKLERED: 0-HR
CORRIDORS NOT REQUIRED TO BE RATED WITH SPRINKLERS IN GROUPS A, B.
MINIMUM WIDTH - NO CHANGES PROPOSED.
DEAD ENDS - NO CHANGES PROPOSED.
NUMBER OF EXITS AND CONTINUITY - NO CHANGES PROPOSED.
EXIT ENCLOSURES - NO CHANGES PROPOSED.
SECTION 1022 EXITS - NO CHANGES PROPOSED.
SECTION 1027 EXTERIOR EXIT STAIRWAYS - NO CHANGES PROPOSED.
SECTION 1028 EXIT DISCHARGE - NO CHANGES PROPOSED.
SECTION 1030 ASSEMBLY - NO CHANGES PROPOSED TO LIBRARY OCCUPANT LOADS OR
EXITING.
CHAPTER 10: MEANS OF EGRESS
EXISTING BUILDING HAS TWO ELEVATORS - NO CHANGES PROPOSED.
CHAPTER 30: ELEVATORS AND CONVEYING SYSTEMS
EXISTING BUILDING IS EQUIPPED THROUGHOUT WITH PORTABLE FIRE
EXTINGUISHERS IN ACCORDANCE WITH SECTION 906. NEW FIRE
EXTINGUISHERS WILL BE LOCATED IN RECONFIGURED OFFICE AREAS AS
REQUIRED PER OFC 2024 - SEE CODE PLAN.
OFC 906 FIRE EXTINGUISHER REQUIREMENTS:
NO CHANGES PROPOSED.
CHAPTER 32: ENCROACHMENTS INTO THE PUBLIC RIGHT-OF-WAY
PROJECT ADDRESS: 225 5TH STREET, SPRINGFIELD, OR 97477
CODE JURISDICTION: CITY OF SPRINGFIELD
APPLICABLE CODES:
2025 OREGON STRUCTURAL SPECIALITY CODE
2024 OREGON FIRE CODE
2025 OREGON MECHANICAL SPECIALTY CODE
2023 OREGON ELECTRICAL SPECIALTY CODE
2023 OREGON PLUMBING SPECIALTY CODE
2025 OREGON ENERGY EFFICIENCY SPECIALTY CODE (OEESC)
NFPA 101 (NOTE: LOCAL CODE WILL TAKE PRECEDENCE. DEVIATIONS FROM NFPA
NOTED IN INDIVIDUAL SECTIONS.)
2024 INTERNATIONAL EXISTING BUILDING CODE (WITH OSSC CH. 34 MODIFICATIONS)
APPLICABLE ZONING:
MIXED-USE COMMERCIAL LAND USE
NODAL DEVELOPMENT LAND USE OVERLAY DISTRICT
CHAPTER 34: EXISTING BUILDINGS
3401.3.5 - EXISTING RISK CATEGORIZATION -
NO CHANGE OF OCCUPANCY OR CHANGE IN OCCUPANT LOAD - EXISTING RISK
CATEGORIZATION ORIGINALLY APPROVED AS A CONDITION OF THE CURRENT,
VALID CERTIFICATE OF OCCUPANCY SHALL BE REFERENCED.
3401.10 - ADDITIONS AND REPLACEMENTS OF EXTERIOR WALL COVERINGS AND
EXTERIOR WALL ENVELOPE
NEW AND/OR REPLACED EXTERIOR WALL COVERINGS WILL COVER LESS THAN
TWO STORIES AND LESS THAN 15% OF TOTAL WALL AREA.
SECTION 3405 - PRESCRIPTIVE COMPLIANCE METHOD
3405.1.2 - FIRE RESISTANCE RATINGS
BUILDING IS SPRINKLERED THROUGHOUT. EXISTING FIRE PROTECTION SYSTEM
WILL BE MODIFIED TO MEET COVERAGE REQUIREMENTS IN RECONFIGURED
SPACES.
3405.3 - ALTERATIONS
3405.3.3 EXISTING STRUCTURAL ELEMENTS CARRYING GRAVITY LOAD -
INCREASE OF DESIGN GRAVITY LOADS ON ELEMENTS LIMITED TO 5%, OR
ELEMENTS MUST BE REPLACED OR ALTERED TO MEET REQUIREMENTS FOR
NEW STRUCTURES.
3405.3.4 EXISTING STRUCTURAL ELEMENTS CARRYING LATERAL LOAD -
EXCEPT AS PERMITTED BY SECTION 3405.3.13, WHERE THE ALTERATION
INCREASES DESIGN LATERAL LOADS, RESULTS IN A PROHIBITED STRUCTURAL
IRREGULARITY AS DEFINED IN ASCE 7, OR DECREASES THE CAPACITY OF ANY
EXISTING LATERAL LOAD-CARRYING STRUCTURAL ELEMENT, THE LATERAL
FORCE-RESISTING SYSTEM OF THE ALTERED BUILDING OR STRUCTURE SHALL
MEET THE REQUIREMENTS OF SECTION 1609 AND SECTION 3403.4.3.2.
EXCEPTIONS:
1) ANY EXISTING LATERAL LOAD-CARRYING STRUCTURAL ELEMENT WHOSE
DEMAND-CAPACITY RATIO WITH THE ALTERATION CONSIDERED IS NOT MORE
THAN 10 PERCENT GREATER THAN ITS DEMAND-CAPACITY RATIO WITH THE
ALTERATION IGNORED SHALL BE PERMITTED TO REMAIN UNALTERED.
2) BUILDINGS IN WHICH THE INCREASE IN THE DEMAND-CAPACITY RATIO IS DUE
ENTIRELY TO THE ADDITION OF ROOFTOP-SUPPORTED MECHANICAL
EQUIPMENT INDIVIDUALLY HAVING AN OPERATING WEIGHT LESS THAN 400
POUNDS (181.4 KG) AND WHERE THE TOTAL ADDITIONAL WEIGHT OF ALL
ROOFTOP EQUIPMENT PLACED AFTER INITIAL CONSTRUCTION OF THE BUILDING
IS LESS THAN 10 PERCENT OF THE ROOF DEAD LOAD. FOR PURPOSES OF THIS
EXCEPTION, "ROOF" SHALL MEAN THE ROOF LEVEL ABOVE A PARTICULAR
STORY.
3405.6 - CHANGE OF OCCUPANCY
NO CHANGE OF OCCUPANCY PROPOSED.
DOORWAY CLEAR WIDTH (§404.2.2)
CLEAR
32" MIN
90.00°
TYP.
36" DOOR
CLEAR
32" MIN
CLEAR
32" MIN 36" MIN
X=0" TYP
X=12" MIN WHEN
DOOR HAS
CLOSER & LATCH
X=36" MIN WHEN Y=60"
X=42" MIN WHEN 54"<Y<60"
IF
D O
O R
H
A S
C L
O S
E R
IF
D O
S
C L
O S
E R
X=0" TYP
X=12" MIN WHEN
DOOR HAS
CLOSER & LATCH
MANEUVERING CLEARANCE (§404.2.3)
M
IN
24" MIN
M
IN
24" MIN22" MIN X 4
M
IN
IF
D O
S
L A
T C
C
L O
S E
R
X
Y
LATCH APPROACH. PULL SIDE LATCH APPROACH, PUSH SIDEHINGE APPROACH. PUSH SIDEHINGE APPROACH. PULL SIDE
X
M
IN
E
M
IN
18" MIN
M
IN
FRONT APPROACH. PUSH SIDEFRONT APPROACH. PULL SIDE
MAXIMUM OVERLAP
OF KNEE & TOE
CLEARANCE (HATCH).
WHEELCHAIR TURNING SPACE (§304)
36" MIN
12" MIN12" MIN
M
IN
M
IN
60" MIN
Ø 60"
EXISTING BUILDINGS / FACILITIES NEW BUILDINGS / FACILITIES
Ø 67"
T-TURN OPTION 1 T-TURN OPTION 2 T-TURN OPTION 3
68" MIN
M
IN
M
IN
36" MIN
16" MIN 16" MIN
8" MIN
M
IN
64" MIN
M
IN
M
IN
11" MIN
42" MIN
11" MIN
64" MIN
M
IN
M
IN
12" MIN
40" MIN
12" MIN
M
A X
@ T-TURN, OVERLAP CAN
ONLY BE AT THE BASE OR A
SINGLE ARM, TYP.
B A
S
E ARM
M
IN
36" MIN
M
IN
M
IN
40" MIN 28" MIN
36" MIN
M
IN
M
IN
8" MIN
38" MIN
M
IN
M
IN
M
IN
T
Y P
24" MAX
PASSING SPACE
OPTION 1 - 60" X 60"
SLOPE
WALKING SURFACE
MAX SLOPE 1:20
MAX CROSS SLOPE 1:48
48" MIN (E)
52" MIN 24" MAX
M
IN
CLEAR WIDTH OF AN ACCESSIBLE ROUTE (§403.5)
M
IN
36" MIN
M
IN
PASSING SPACE
OPTION 2 -
INTERSECTION W/
T-SHAPED TURNING
SPACE, PROVIDED
THE BASE AND ARMS
EXTEND 52" MIN PAST
THE INTERSECTION.
T-TURN OPTIONS 1, 2
OR 3 CAN BE USED,
SO LONG AS MINIMUM
DIMENSIONS OF
T-TURN ARE MET.
48" MIN (E)
52" MIN
M
IN
E
M
IN
M
IN
E
M
IN
Y
X
X
Z
CLEAR WIDTH AT 180° TURN
Y=60" MIN WHEN X=36" MIN & Z<52" MIN
Y=48" MIN WHEN X=42" MIN & Z<52" MIN
Y=43" MIN WHEN X=43" MIN & Z<52" MIN
CLEAR WIDTH AT 180° TURN (EXISTING)
Y=60" MIN WHEN X=36" MIN & Z<48"
Y=48" MIN WHEN X=42" MIN & Z<48"
CLEAR WIDTH AT 90-DEGREE TURN
OPTION 1 OPTION 2 OPTION 3 OPTION 4
36" MIN
M
IN
36" MIN
M
IN
EXISTING BUILDINGS / FACILITIES
NOTE:
• CHANGES IN LEVEL ARE
NOT PERMITTED WITHIN
THE CLEAR FLOOR
SPACE.
• SLOPES NO STEEPER
THAN 1:48 SHALL BE
PERMITTED WITHIN THE
CLEAR FLOOR SPACE.
• CLEAR FLOOR SPACE
SHALL BE PERMITTED
TO INCLUDE KNEE AND
TOE CLEARANCE.
CLEAR FLOOR SPACE
CLEAR FLOOR SPACE (§305)
CLEAR FLOOR SPACE
48" MIN
M
IN
52" MIN
M
IN
EXISTING BUILDINGS / FACILITIES
NEW BUILDINGS / FACILITIES
M
IN
M
IN
PROTRUDING
CEILING OBJECT
PROTRUDING
WALL OBJECT
NOTE: SEE 404.2.2 FOR RESTRICTIONS ON PROTRUDING OBJECTS INTO CLEAR OPENING WIDTHS
4" MAX
CIRCULATION
PATH
CLEAR
WIDTH
PROTRUDING
OBJECT IN
DETECTABLE
RANGE
CIRCULATION
PATH
CLEAR
WIDTH
M
A X
> 4"
OR PROVIDE
CANE DETECTION
M
IN
V E
R T
IC
A
L C
L E
A R
A N
C E
M
A X
WALL & CEILING MOUNTED OBJECTS FLOOR MOUNTED OBJECTS REDUCED VERTICAL CLEARANCE
GUARDRAILS OR OTHER BARRIER TO
BE PROVIDED WHEN VERTICAL
CLEARANCE IS LESS THAN 80" AT A
HEIGHT OF 27" MAX
OUTLINE OF BENCH BELOW ATRIUM STAIR
THAT PROVIDES REQUIRED BARRIER
PROTRUDING OBJECTS (§307)
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:1
P
M
G-002
CODE SUMMARY
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/4" = 1'-0"G-002
3 DOOR CLEAR WIDTH
1/4" = 1'-0"G-002
1 DOOR MANEUVERING CLEARANCE - STANDARD SWING DOORS
1/4" = 1'-0"G-002
4 TURNING SPACE - CIRCULAR & T-SHAPED
1/4" = 1'-0"G-002
6 ACCESSIBLE ROUTE
1/4" = 1'-0"G-002
2 CLEAR FLOOR SPACE
1/4" = 1'-0"G-002
5 PROTRUDING OBJECTS IN CIRCULATION PATH
F.F.
ACCESSIBLE MOUNTING HEIGHTS
SEAT
COVER
DISPENSER
SANITARY
NAPKIN
RECEPTACLE
HAND DRYER
W/ WALL MOUNT
WASTE RECEPTACLE
SHELF COAT
HOOK
LAVATORY
R E
A C
H R
A N
G E
F A
U C
E T
M O
U N
T H
E
IG
H T
R E
A C
H R
A N
G E
SOAP
DISPENSER
M
A X
M
IN
M
IN
TOILET
PAPER
DISPENSER
INSULATE
PIPES PER
SPECS
BABY
CHANGING
STATION
M
A X
T O
C H
A N
G
IN
G S
U R
F A
C E
WALL MOUNT
FLUSH
CONTROL
GRAB BARS
T
Y P
WASTE
RECEPTACLE
ELECTRIC
HAND DRYER
ELECTRICAL
SWITCH
ELECTRICAL
OUTLET
FIRE
ALARM
PULL
FIRE
EXTINGUISHER
(15" MIN TO HANDLE)
THERMOSTAT
M
A X
T O
H A
N D
L E
M
A X
M
IN
T
O
T.O. BAR
T O
R
IM
M
A X
M
A X
OPERABLE
WINDOW
OPERATOR
LOCK
MIRROR
OVER
LAV/COUNTER
M
A X
P R
E F
E R
R E
D
MIRROR
NOT OVER
LAV/COUNTER
M
A X
P R
E F
E R
R E
D
TOWEL
BAR
HAND TOWEL
LOOP
WINDOW TO COMPLY WITH REACH RANGE WHEN
REQUIRED TO PROVIDE NATURAL VENTILATION OR AN
EMERGENCY ESCAPE AND RESCUE OPENING. WHEN
PROVIDED IN AN ACCESSIBLE ROOM, AT LEAST ONE
OPERABLE WINDOW SHALL ALSO COMPLY (§506.1).
44" MAX @ COUNTER
IN PUBLIC SPACES &
TYPE A UNITS.
46" MAX @ COUNTER
IN TYPE B UNITS.
ACCESSIBLE DRINKING FOUNTAIN (§602)
KNEE & TOE CLEARANCE
CLEARANCE FOR FORWARD APPROACH
*SPOUT HEIGHT FOR STANDING
PERSONS TO BE 38" MIN & 43" MAX
36" MIN IF X>24"
30" MIN
M
IN
E
M
IN
M A
X
PROTRUDING
OBJECT (§307)
6" MAX
8" MIN
DEPTH
17" MIN
M
IN9
" 2
M
IN
T O
S P
O U
T
M
A X
EQUIPMENT PERMITTED
IN SHADED REGION
5" MAX TO SPOUT 15" MIN TO SPOUT
11" MIN
X
60" MIN
M
IN
35" - 37"
M
IN
17"-19"
M
IN
AMBULATORY ACCESSIBLE COMPARTMENT
X
60" MIN
X=56" MIN @ WALL-HUNG WC
X=59" MIN @ FLOOR-MOUNTED WC
X=84" MIN @ FRONT PARTITION IN-SWING
4" MAX
56" MINOR
M
IN
FRONT PARTITION
CLEAR
32" MIN
WATER CLOSET CLEARANCE
T
T
T
T
60" MIN
X
M A
X X
M
IN
SIDE PARTITION
O R
NOTE: WATER CLOSET CLEARANCE SHALL BE PERMITTED TO OVERLAP THE WATER
CLOSET, ASSOCIATED GRAB BARS, PAPER DISPENSERS, SANITARY NAPKIN
RECEPTACLES, COAT HOOKS, SHELVES, ACCESSIBLE ROUTES, CLEAR FLOOR SPACE AT
OTHER FIXTURES AND THE TURNING SPACE. NO OTHER FIXTURES OR OBSTRUCTIONS
SHALL BE PERMITTED WITHIN THE WATER CLOSET CLEARANCE. (§604.3.3)
PARTITION DOORS TO BE SELF-CLOSING, TYP.
ADULT WATER CLOSETS & TOILET COMPARTMENTS (§604)
T=TOE CLEARANCE (§604.9.5)
MINIMUM OF 8" DEEP, MEASURED FROM INSIDE FACE OF PARTITON, BY 12" TALL,
MEASURED FROM FLOOR, EXCLUSIVE OF PARTITION SUPPORT MEMBERS.
EXCEPTION ALLOWED AT FRONT PARTITION IF COMPARTMENT GREATER THAN
64" IN DEPTH @ WALL-HUNG, OR 67" IN DEPTH @ FLOOR-MOUNTED WC.
SIDE PARTITION EXCEPTION IF COMPARTMENT GREATER THAN OR 68" IN WIDTH.
8"
M
IN
REQUIRED AREA OF BLOCKING AT FRAMED WALL.
COORDINATE BLOCKING WITH GRAB BAR LOCATIONS.
WATER CLOSET TOILET & GRAB BAR LOCATIONS (§604)
GB-2
GB-1 IS 36" BACK GRAB BAR
GB-2 IS 42" SIDE GRAB BAR
GB-3 IS 18" VERTICAL GRAB BAR
54" MIN.
M
A X
M
IN
39" MIN - 41" MAX
MAX
12"
M
A X
M
IN42" MIN
M
INGB-3
GB-1
18" MAX
16" MIN
12" MIN
24" MIN
M
A X
M
IN
M
A X
M
IN
FLUSH CONTROLS
LOCATED ON OPEN SIDE
OF WATER CLOSET
PROTRUDING DISPENSER RECESSED DISPENSER
TOILET PAPER DISPENSERS (§604.7)
24" MIN
M
IN
/2
M
IN
42" MAX
36" MAX
M
IN
42" MAX
M
IN 4
M
A X
24" MIN
36" MAX
M
IN
M
A X
DISPENSER EXCEPTION
7" - 9"
PROTRUDING
DISPENSER THAT
ACCOMODATES
MAX 2 ROLLS OF
Ø 5" MAX EACH
URINAL HEIGHT & DEPTH (§605.2)
M A
X
13 1/2" MIN 13 1/2" MIN
WALL HUNG TYPE FLOOR TYPE
KNEE & TOE CLEARANCE CLEAR FLOOR SPACE @ LAVATORY / SINK
R
IM
O F
S
IN
K
M
A X
M
IN9
" 2
M
A X
8" MIN
11" MIN 6" MAX
25" MAX
17" MIN
ACCESSIBLE LAVATORIES AND SINKS (§606)
CLEAR FLOOR SPACE
PER §305
A PARALLEL APPROACH
C.F.S., IS PERMITTED @ WET
BARS & KITCHENS WITHOUT A
COOKTOP OR CONVENTIONAL
RANGE
COUNTERTOP KNEE & TOE
CLEARANCE
UNDER COUNTER
NOTES:
1. EQUIPMENT PERMITTED IN SHADED REGION.
2. WATER SUPPLY AND DRAIN PIPES UNDER SINKS SHALL
BE INSULATED OR OTHERWISE CONFIGURED TO
PROTECT AGAINST CONTACT. THERE SHALL BE NO
SHARP OR ABRASIVE SURFACES UNDER SINKS.
30" MIN
M
IN
36"
48" MIN (E)
52" MIN
BACK WALL
CONTROL
WALL
SEAT
WALL
TRANSFER SHOWER SIZE AND
CLEARANCE (§608.2.1)
18"
BACK WALL CONTROL WALL
CONTROLS & HAND
SHOWER AREA
(C O
N T
R O
L S
M
IN
(C O
N T
R O
L S
M
A X
(CONTROLS)
15" MAX
M
A X
M
IN
FOLDING L-SHAPED
SEAT.
SIZE & LOCATION
PER (§610.3.2)
SEAT
HATCHED AREA DENOTES IN-WALL REINFORCEMENT LOCATIONS FOR GRAB BARS AND SHOWER SEATS.
4" MAX
GRAB BARS (§608.3.1) , CONTROLS & HAND SHOWER LOCATIONS (§608.4.1)
HAND SHOWER W/ HOSE 59" MIN IN
LENGTH & FIXED SHOWER HEAD ABILITY
M
IN
M
IN
60" MIN
END
WALL
BACK WALL
END
WALL
STANDARD ROLL-IN-TYPE SHOWER
SIZE AND CLEARANCE (§608.2.2)
BACK WALL END WALL
GRAB BAR
SHALL NOT BE
PROVIDED
ABOVE SEAT
END WALL
6" MAX6" MAX
A B
O V
E G
R A
B B
A R
/2
M
IN
CONTROLS &
HAND SHOWER
AREA
M
A X
16" MIN
27" MAX
FOLDING SEAT.
SIZE & LOCATION
PER (§610.3.1)
SEAT
GRAB BARS (§608.3.2) , CONTROLS & HAND SHOWER LOCATIONS (§608.4.2)
HATCHED AREA DENOTES IN-WALL REINFORCEMENT LOCATIONS FOR GRAB BARS AND SHOWER SEATS.
HAND SHOWER W/ HOSE
59" MIN IN LENGTH & FIXED
SHOWER HEAD ABILITY
M
A X
M
IN
LAVATORY COMPLYING
W/ §606 PERMITTED
"3
M
IN
4" MAX
ALTERNATE ROLL-IN-TYPE
SHOWER SIZE (§608.2.3)
24" - 36" 36" MIN
END
WALL
SEAT
WALL
BACK WALL
6" MAX
6" MAX
END WALL
FOLDING SEAT.
SIZE & LOCATION
PER (§610.3.1)
GRAB BAR SHALL
NOT BE PROVIDED
ABOVE SEAT
6" MAX
M
IN
M
A X
15" MAX15" MAX
CL OF SEAT
ON SEAT WALL
CONTROLS AREA
(OPTION 1)
27" MAX
M
IN
M
A X
CONTROLS AREA
(OPTION 2)
SEAT
HATCHED AREA DENOTES IN-WALL REINFORCEMENT LOCATIONS FOR GRAB BARS AND SHOWER SEATS.
60" MIN
HAND SHOWER W/ HOSE
59" MIN IN LENGTH & FIXED
SHOWER HEAD ABILITY
SIDE
WALL
BACK WALL
GRAB BARS (§608.3.3) , CONTROLS & HAND SHOWER LOCATIONS (§608.4.3)
MIN
16"
22" - 23"
/2
M A
X
M
A X
2 1/2" MAX
15" - 16"
L-SHAPED SHOWER
SEAT (§610.3.2)
RECTANGULAR SHOWER
SEAT (§610.3.1)
2 1/2" MAX
15" - 16"
M A
X
OPEN
SIDE
OPEN SIDE /
ALTERNATE ROLL-IN SHOWER
SEAT WALL END
2" MAX2" MAX
/4
M
IN
M
A X
Ø
/2
M
IN
O R
Y
M
IN
1 1/2" CLEAR
4" TO 4.8"
PERIMETER
CIRCULAR
W/ SPACING
NON-CIRCULAR
B E
L O
W A
B O
V E
** RECESSED DISPENSERS PROJECTING
FROM THE WALL 1/4" MAX SHALL BE
PERMITTED WITHIN THE SPACE 12" ABOVE
& 1 1/2" BELOW.
* Y=1 1/2" MIN FOR SHOWER CONTROLS,
FITTINGS, & OTHER GRAB BARS ABOVE
GRAB BARS SIZE & SPACING (§609)
1 PER COUNTER
ADA PORTION
36" MIN WIDTH
A D
A
M
A X
SERVICE COUNTER
DINING & WORK SURFACES* (§902) SALES & SERVICE COUNTERS (§904)
30" MIN CLEAR
ACCESSIBLE COUNTER
TO EXTEND SAME DEPTH
AS SERVICE COUNTER
FOR A PARALLEL APPROACH, A PORTION OF COUNTER SURFACE,
36" MIN IN LENGTH & 36" MAX IN HEIGHT, SHALL BE PROVIDED.
FOR A FORWARD APPROACH, A PORTION OF COUNTER
SURFACE, 30" MIN IN LENGTH & 36" MAX IN HEIGHT, SHALL BE
PROVIDED. PROVIDE KNEE & TOE CLEARANCE PER (§306)
CLEAR
30" MIN
M
IN
M
A X
DINING / WORK SURFACE
CLEAR FLOOR SPACE
CENTERED ON WORK
SURFACE
PROVIDE KNEE & TOE
CLEARANCE PER (§306)
*NOTE, EMPLOYEE WORK AREAS
ARE EXEMPT PER OSSC §1103.2.3
REF
DW
COUNTERTOP
AN ADJACENT CLEAR FLOOR SPACE SHALL
BE PROVIDED; THE DISHWASHER DOOR IN
THE OPEN POSITION SHALL NOT
OBSTRUCT THE CLEAR FLOOR SPACE FOR
THE DISHWASHER OR AN ADJACENT SINK
DISHWASHER (§804.5.3)REFRIGERATOR (§804.5.6)
COMBINATION REFRIGERATORS AND FREEZERS SHALL HAVE
AT LEAST 50 PERCENT OF THE FREEZER COMPARTMENT
SHELVES, INCLUDING THE BOTTOM OF THE FREEZER 54" MAX
ABOVE THE FLOOR WHEN THE SHELVES ARE INSTALLED AT
THE MAXIMUM HEIGHTS POSSIBLE IN THE COMPARTMENT.
OFFSET 24" MAX ALLOWED
CL, REF
CL, CLEAR FLOOR SPACE
CLEAR FLOOR SPACE,
PARALLEL APROACH
UNOBSTRUCTED SIDE REACH OBSTRUCTED HIGH SIDE REACH UNOBSTRUCTED FORWARD REACH OBSTRUCTED HIGH FORWARD REACH
FORWARD & SIDE REACH RANGES (§308)
X
FOR 0" < X ≤ 20"
THEN Y ≤ 48"
Y
FOR 20" < X ≤ 25"
THEN Y ≤ 44"
M
IN
M
A X
M
IN
M
A X
10" MAX
FOR 0" < X ≤ 10"
THEN Y ≤ 48"
FOR 10" < X ≤ 24"
THEN Y ≤ 46"
X
Y
M
A X
/4
M
A X
VERTICAL LEVEL CHANGE COMBO LEVEL CHANGE
/2
M
A X
/4
M
A X
BEVELED LEVEL CHANGE
/4
/2
CARPET ON FLOOR SURFACE
/2
M
A X
CUSHION, PAD
OR BACKING
CARPET PILE
OPENINGS IN FLOOR SURFACE
1/2" MAX
D
IM
E N
S
IO
N
L O
N G
PERPENDICULAR
TO DIRECTION
OF TRAVEL
FLOOR SURFACE (§302) & LEVEL CHANGES ON ACCESSIBLE ROUTE (§303)
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
Owner
PERMIT 2017.02.28
PRICING 2016.12.19
PRICING 2017.04.07
NOT FOR CONSTRUCTION
DESCRIPTION
/2
/2
:0
:1
P
M
G-004
ACCESSIBILITY -
PUBLIC SPACES
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/4" = 1'-0"G-004
1 MOUNTING HEIGHTS
1/4" = 1'-0"G-004
2 CLEARANCE AT DRINKING FOUNTAIN
1/4" = 1'-0"G-004
10 TOILET CLEARANCES
1/4" = 1'-0"G-004
11 TOILET GRAB BARS
1/4" = 1'-0"G-004
9 TOILET PAPER DISPENSER LOCATIONS
1/4" = 1'-0"G-004
12 URINAL SECTIONS
1/4" = 1'-0"G-004
8 CLEARANCE AT LAVATORY
1/4" = 1'-0"G-004
3 TRANSFER SHOWER
1/4" = 1'-0"G-004
4 STANDARD ROLL-IN SHOWER
1/4" = 1'-0"G-004
5 ALTERNATE ROLL-IN SHOWER
1/4" = 1'-0"G-004
6 SHOWER SEAT SIZE
1" = 1'-0"G-004
7 SHOWER GRAB BARS
1/4" = 1'-0"G-004
13 COUNTERS AND WORK SURFACES - PUBLIC SPACES
1/4" = 1'-0"G-004
14 KITCHEN APPLIANCES
1/4" = 1'-0"G-004
15 REACH RANGE
6" = 1'-0"G-004
16 LEVEL CHANGES - FLOOR SURFACE
WALL TAG IS PLACED IN PLAN ON
SIDE OF WALL WITH GWB LAYER
S1
STEEL STUD @ 24" O.C. MAX
GWB
FURRING WALL
INSULATION, WHERE NOTED BELOW
S1A
ADD SOUND ATTENUATION BLANKET TO S1, THICKNESS
NOT TO EXCEED STUD DEPTH.
INTERIOR WALL ASSEMBLIES - STEEL
3 1/8" @ 2 1/2" STUDS
4 5/8" @ 4" STUDS
6 5/8" @ 6" STUDS
S2
STEEL STUD @ 24" O.C. MAX
GWB (2 LAYERS)
SOUND ATTENUATION BLANKET
(@ S2A ONLY)
S2A
SOUND RATING NOTE:
48 STC SOUND WHEN SOUND ATTENUATION BLANKET
ADDED TO ASSEMBLY PER GA FILE NO. WP 1072.
STUDS MUST BE 25GA OR 20G EQ TO ACHIEVE SOUND
RATING.
3 3/4" @ 2 1/2" STUDS
5 1/4" @ 4" STUDS
7 1/4" @ 6" STUDS
FIRE RATING NOTES:
• @ 1HR RATED* LOCATIONS,
• ASSEMBLY SHALL CONFORM TO GA FILE NO. WP 1072.
FIRE RATING LISTED ON ASSEMBLY DRAWINGS IS THE MAXIMUM FIRE RATING ACHIEVABLE FOR THAT ASSEMBLY. SOME WALLS HAVE BEEN CHOSEN FOR THEIR STC RATING AND MAY NOT BE REQUIRED PER CODE TO MEET THE FIRE RATING LISTED ON ASSEMBLIES.
CHECK INTERIOR PARTITION TYPE TAG ON FLOOR PLANS FOR ACTUAL FIRE RATING.
FURRING WALL
VAPOR RETARDER (@S1E ONLY)
FLOOR TRACK, GALV. 25 GA. MIN.
WALL BASE PER FINISH PLAN
WALL ASSEMBLY PER PLAN
HOLD GWB 1/2" ABOVE
CONCRETE, TYP.
INSULATION WHERE OCCURS
WALL ASSEMBLY PER PLAN
SEALANT BETWEEN GWB &
UNDERSIDE OF ROOF SHEATHING
DEFLECTION HEAD TRACK
DO NOT FASTEN GWB TO
DEFLECTION TRACK.
SHIM AS NECESSARY
(E) ROOF DECK
WALL ASSEMBLY PER PLAN
INSULATION - WHERE
OCCURS
45.00°
BRACE WITH METAL STUDS AT
8'-0" MAX O.C. WHERE POSSIBLE,
ALTERNATE DIRECTION OF
BRACES ALONG LENGTH OF WALL
3"x3"x3" ANGLE (20 GA MIN)
FASTENED TO
DEFLECTION HEAD
DEFLECTION HEAD
M A
X
M A
X
M
A X
T O
T A
L S
P A
N
WALL ASSEMBLY PER PLAN
CEILING PER PLAN
STUD SPACING PER WALL ASSEMBLY
MIN (3) #10 S.M.S. @ EACH END, TYP.
MIN 2X6 WOOD BACKING. FASTEN TO
STUD AT EACH END
KERF BACKING AT STUD LIP SO THAT
BACKING SITS TIGHT TO STUD FLANGE
BACKING NOTES:
1. PROVIDE BACKING AT ALL WALL NOUNTED ITEMS. VERIFY WEIGHTS,
DIMENSIONS, AND BACKING REQUIREMENTS FOR ITEMS TO BE
SUPPORTED.
2. THIS DIAGRAM SHOWS DESIGN INTENT ONLY. CONTRACTOR SHALL
DESIGN AND PROVIDE BACKING AS REQUIRED TO SUPPORT WALL
MOUNTED ITEMS. NON-STRUCTURAL INTERIOR FRAMING SHALL BE
DESIGNED BY A REGISTERED ENGINEER.
3. EXTEND BACKING THE FULL LENGTH OF WALL @ CABINETS OR
SHELVING.
4. AT RESTROOMS, EXTEND BACKING MIN. 1'-0" ABOVE, BELOW & TO EACH
SIDE OF TOILET ACCESSORIES.
P A
R T
IT
IO
N
R A
T E
D
PARTITION
RATED
PARTITION
ACOUSTIC
PARTITION
NON-RATED
JOINT
TAPE,
TYP.
HOLD FRAMING
BACK FROM
RATED
PARTITION TO
ALLOW FOR
CONTINUATION
OF GWB
LAYER(S)
1/4" GAP @ GWB
TERMINATION.
FILL GAP W/
SEALANT.
TAPE JOINT.
LAP GWB LAYERS
@ CORNER
INTERRUPT INTERIOR
GWB LAYER FOR
PARTITION STUD
WHEN INTERSECTING
PARTITIONS ARE OF
EQUAL RATING
LAP GWB LAYERS @ CORNER
DRYWALL CORNER BEAD, TYP. @ OUTSIDE CORNER
S E
A L
A N
T J
O
IN
T
SEALANT
EXISTING FLOOR SLAB
FLOOR TRACK
WALL BASE PER FINISH PLAN
WALL ASSEMBLY PER PLAN
EXISTING ROOF
DEFLECTION HEAD TRACK, 25 GA. MIN.
SEALANT
S E
A L
A N
T J
O
IN
T
DO NOT SECURE GYPSUM SHEATHING TO
DEFLECTION TRACK. FASTENERS PER
LISTED ASSEMBLYWALL ASSEMBLY PER PLAN
B.O (E) ROOF DECK
CEILING LINE
FLOOR
B.O. STRUCTURE
- ^ + 0 1 2 3
FIRE RATING / PARTITION HEIGHT DESIGNATION
- : PARTIAL HEIGHT PARTITION. SEE PLAN AND ELEVATIONS FOR SPECIFIED
HEIGHT
^ : NON RATED TO B.O. CEILING
+ : NON RATED. EXTEND STUDS TO B.O. STRUCTURE ABOVE.
EXTEND GYP BOARD 6" ABOVE TOP OF CEILING U.N.O.
0 : NON RATED. EXTEND STUDS TO B.O. STRUCTURE ABOVE.
EXTEND GYP. BOARD BOTH SIDES TO B.O. STRUCTURE ABOVE U.N.O.
1 : (1) HOUR FIRE RATED ASSEMBLY
2 : (2) HOUR FIRE RATED ASSEMBLY
3 : (3) HOUR FIRE RATED ASSEMBLY
KEY
STEEL FRAMING SIZE DESIGNATION
0 = 7/8" HC
1 = 1 1/2" HC
2 = 2 1/2" 3 = 3 5/8" 4 = 4" 6 = 6"
ID. STUD SIZE
WALL TYPE
EXTERIOR WALL TYPE TAG
GENERAL NOTES - WALL TYPES
1. NOT ALL WALL CONFIGURATIONS ILLUSTRATED ON ASSEMBLIES SHEET ARE PRESENT IN THIS PROJECT.
COORDINATE WALL TAGS IN DRAWINGS WITH CONFIGURATIONS SHOWN HERE.
2. WALL ASSEMBLIES WHERE NOTED AS FIRE RATED SHALL CONFORM TO CONFIGURATIONS AS NOTED IN
GA FILE, UL FILE, ESR, OR OTHER TESTED ASSEMBLY INFORMATION.
3. FIRE RATING LISTED ON ASSEMBLY DRAWINGS IS THE MAXIMUM FIRE RATING ACHIEVABLE FOR THAT ASSEMBLY. SOME WALLS HAVE BEEN CHOSEN FOR THEIR STC RATING AND MAY NOT BE REQUIRED PER CODE TO MEET THE FIRE RATING LISTED ON ASSEMBLIES. CHECK INTERIOR PARTITION TYPE TAG ON FLOOR
PLANS FOR ACTUAL FIRE RATING.
4. ALL GYPSUM WALL BOARD (GWB) TO BE 5/8" TYPE X U.N.O.
5. "A" NOTE IN PARTITION AND EXTERIOR WALL TYPE DESIGNATION REFERS TO "ACOUSTIC".
- AT INTERIOR "A" TYPE WALLS, PROVIDE SOUND ATTENUATION BLANKET.
- AT "A" TYPE METAL STUD WALLS, STUDS TO BE 25GA OR 20G EQ (SCAFCO SUPREME D20 OR CLARK
DIETRICH PRO)
6. SOUND ATTENUATION BLANKET TO BE THE FULL DEPTH OF STUD CAVITY U.N.O.
7. RESILIENT CHANNELS TO BE CLARK DIETRICH RC DELUXE (RCSD) OR CEMCO RC1-XD ONLY.
8. STOREFRONT SYSTEMS ARE CALLED OUT SEPARATELY FROM WALL TYPES AND ARE SCHEDULED
ELSEWHERE IN THE DOCUMENT SET.
9. AT LOCATIONS NOTED TO HAVE WALL TILE FINISH, SUBSTITUTE CEMENTITIOUS BACKER BOARD FOR GWB
AS TILE SUBSTRATE PER SPECIFICATIONS.
10. SEE FINISH SCHEDULE FOR WALL AND CEILING FINISHES. SEE INTERIOR ELEVATIONS AND FINISH
SCHEDULE FOR TILE EXTENTS.
11. "PRIMARY" LAYER IS THE LAYER AT THE FACE OF STUD.
FLOOR, ROOF, & CEILING TYPE TAG
ASSEMBLY TYPE
PARTITION TYPE
FIRE RATING / PARTITION
HEIGHT DESIGNATION
STUD FRAMING / CMU SIZE
DESIGNATION
INTERIOR PARTITION TYPE TAG
11 = (2) 1 5/8".
22 = (2) 2 1/2" 33 = (2) 3 5/8" 44 = (2) 4" 66 = (2) 6"
LOCATION OF TAG INDICATES SIDE OF
WALL TO RECEIVE ADDITIONAL LAYERS OF
GYP WHEN INDICATED BY THE PARTITION
TYPE
(EXCEPTION: SHAFT WALLS SH1 & SH2
TAGGED @ SHAFTLINER SIDE OF WALL)
WOOD FRAMING SIZE DESIGNATION
1 = 1X (3/4" FURRING)
2 = 2X2 (1 1/2")
3 = 2X3 (2 1/2") 4 = 2X4 (3 1/2") 6 = 2X6 (5 1/2")
ID. STUD SIZE
8 = 2X8 (7 1/4")
10 = 2X10 (9 1/4")
44 = (2) 2X4 64 = 2X6 & 2X4 66 = (2) 2X6
COLOR FILL @ 1HR
RATED WALLS
SUBSTITUTE 3X MATERIAL FOR 2X MATERIAL AS NOTED IN
STRUCTURAL DESIGN.
63 = (1) 6" & (1) 3 5/8"
NOTE: @ STAGGERED
STUDS, SIZE DENOTES
PLATE SIZE. SEE
ASSEMBLIES FOR STUD SIZE
COLOR FILL @ 2HR RATED
WALLS
ACOUSTIC PARTITIONS
PARTITION WALL TYPES THAT END WITH AN "A" DESIGNATION, ARE ACOUSTIC WALLS.
THESE ARE NOTED VISUALLY IN PLAN WITH A HONEYCOMB HATCH.
IF RATED, THE WALL SHOWS BOTH ACOUSTIC AND FIRE RATING HATCH.
XXA
XX 1
XXA
XX 2
XXA
XX 3
XXA
XX
COLOR FILL @ 3HR RATED
WALLS
XXX
1 XX
C1-A
EW1
WALL ASSEMBLY PER PLAN
DEFLECTION HEAD TRACK
DO NOT FASTEN GWB TO
DEFLECTION TRACK. (E) TRUSS
CONTINUE WALL UP TO B.O.
ROOF DECK BETWEEN
TRUSSES - SEE DETAIL
/3 A-001
SEALANT - CONTINUE AT GWB
EDGE AROUND TRUSS, BEYOND
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:1
P
M
A-001
ASSEMBLIES
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
3" = 1'-0"A-001
1 NON-RATED PARTITION TO FLOOR CONNECTION, TYP.
1 1/2" = 1'-0"A-001
3 T.O. WALL PARALLEL TO TRUSS
1 1/2" = 1'-0"A-001
2 TOP OF WALL NON-RATED BRACED PARTITION, TYP.
1 1/2" = 1'-0"A-001
10 TYP. PARTITION WALL BACKING
1 1/2" = 1'-0"A-001
9 TYP MTL STUD PARTITION INTERSECTIONS
3" = 1'-0"A-001
5 ACOUSTIC BASE-OF-WALL
3" = 1'-0"A-001
6 ACOUSTIC HEAD-OF-WALL
1 1/2" = 1'-0"A-001
4 T.O. WALL PERPENDICULAR TO TRUSS
D
D
WH
4A 5 61 2 3 7 8 10 129 114
13 14 15 16 1817
A
B
C
D
F
H
M
L
K
J
I
G
E
REMOVE ALL (E) PLUMBING
FIXTURES AND CAP (E) PIPES.
REMOVE (E) PLUMBING
FIXTURE AND CAP
EXISTING PIPES.
DEMO OPENING IN (E) WALL
FOR NEW WINDOW OPENINGS -
SEE ELEVATIONS.
DEMO OPENING IN (E) WALL
FOR NEW WINDOW - SEE
ELEVATIONS.
REMOVE ALL (E) PLUMBING
FIXTURES AND CAP (E)
PIPES, THESE ROOMS.
CUT NEW DOOR OPENING
DEMO ALL (E) FLOORING
FINISHES IN SOUTHEAST QUAD -
REFER TO FINISH PLANS.
DEMO (E) LIBRARY CARPET
FLOORING WHERE NOT
RECENTLY UPDATED - REFER
TO FINISH PLANS AND VFY
EXTENTS IN FIELD.
DEMO ALL (E) FLOORING
FINISHES IN NORTH QUAD -
REFER TO FINISH PLANS.
SERVER
MEN
223.A
WOMEN
223.B
LIBRARY MTG
DEMO (E) CARPET
FLOORING - REFER
TO FINISH PLANS.
(E) STORM DRAIN
CHASE TO REMAIN
(E) STORM DRAIN
CHASE, VIF
(E) STORM DRAIN
CHASE TO REMAIN, VIF
(E) STORM DRAIN CHASE
TO REMAIN, VIF
DEMO (E) CARPET FLOORING
WHERE NOT RECENTLY
UPDATED - REFER TO FINISH
PLANS.
DEMO (E) LIBRARY CARPET
FLOORING WHERE NOT
RECENTLY UPDATED - REFER
TO FINISH PLANS AND VFY
EXTENTS IN FIELD.
DEMO (E) LADDER.
SOUTH EAST QUAD
GENERAL NOTES - DEMO PLANS
1. EXISTING ELEMENTS ARE TO REMAIN UNLESS NOTED OTHERWISE.
2. SEE MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS FOR INFO ON MEP
DEMOLITION.
3. SALVAGE FOR RE-INSTALL EXISTING INTERIOR COMPONENTS, SUCH AS
INTERIOR BLINDS, PIPING AND HVAC-RELATED FIXTURES, WHERE
REMOVAL IS NECESSARY.
4. DO NOT DEMOLISH ANY LOAD-BEARING ELEMENTS UNLESS INDICATED
ON THESE DRAWINGS.
5. REMOVE (E) PLUMBING FIXTURES AND PREP FOR TIE-IN OF NEW
PLUMBING FIXTURES TO EXISTING DRAINS, PER PLUMBING PLANS, UNO.
6. REFER TO MEP FOR LIBRARY LIGHTING AND DUCTWORK DEMOLITION
SCOPE.
7. SALVAGE EXISTING CEILING GRIDS AND ACOUSTIC CEILING TILE FOR
REINSTALLATION WHERE EXISTING CEILINGS TO REMAIN WILL REQUIRE
PATCHING - SEE RCP.
8. WHERE EXISTING FINISHES WERE RECENTLY UPDATED, REMOVE AND
SAVE MATERIALS FOR REINSTALLATION. VERIFY IN FIELD AND CONFIRM
W/ ARCHITECT.
DEMO KEY:
EXISTING TO REMAIN DEMO DEMOLISH EXISTING DOOR,
EXISTING WALL TO REMAIN
MODIFY EXISTING AS NOTED
DEMO EXISTING ACT AND GRID
EXISTING ACT AND GRID TO REMAIN
DEMO EXISTING GYP/PLASTER CEILING
EXISTING GYP/PLASTER CLG TO REMAIN
1/16" = 1'-0"D-101
1 2ND FLOOR PLAN - OVERALL DEMO
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:1
P
M
D-101
DEMO PLAN - OVERALL
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
GENERAL NOTES - DEMO PLANS
1. EXISTING ELEMENTS ARE TO REMAIN UNLESS NOTED OTHERWISE.
2. SEE MECHANICAL, ELECTRICAL, PLUMBING DRAWINGS FOR INFO ON MEP
DEMOLITION.
3. SALVAGE FOR RE-INSTALL EXISTING INTERIOR COMPONENTS, SUCH AS
INTERIOR BLINDS, PIPING AND HVAC-RELATED FIXTURES, WHERE
REMOVAL IS NECESSARY.
4. DO NOT DEMOLISH ANY LOAD-BEARING ELEMENTS UNLESS INDICATED
ON THESE DRAWINGS.
5. REMOVE (E) PLUMBING FIXTURES AND PREP FOR TIE-IN OF NEW
PLUMBING FIXTURES TO EXISTING DRAINS, PER PLUMBING PLANS, UNO.
6. REFER TO MEP FOR LIBRARY LIGHTING AND DUCTWORK DEMOLITION
SCOPE.
7. SALVAGE EXISTING CEILING GRIDS AND ACOUSTIC CEILING TILE FOR
REINSTALLATION WHERE EXISTING CEILINGS TO REMAIN WILL REQUIRE
PATCHING - SEE RCP.
8. WHERE EXISTING FINISHES WERE RECENTLY UPDATED, REMOVE AND
SAVE MATERIALS FOR REINSTALLATION. VERIFY IN FIELD AND CONFIRM
W/ ARCHITECT.
DEMO KEY:
EXISTING TO REMAIN DEMO DEMOLISH EXISTING DOOR,
EXISTING WALL TO REMAIN
4A 5 61 2 3 7 8 10 129 114
13 14 15 16 1817
A
B
C
D
F
H
M
L
K
J
I
G
E
EXISTING SKYLIGHT
WELLS TO REMAIN
NOTE: SEE MEP FOR MECHANICAL
DUCTWORK AND LIGHTING DEMO.
DEMO (E) LADDER
AND LEAVE (E) ROOF
HATCH IN PLACE.
SELECTIVELY DEMO (E)
STUCCO SOFFIT FOR NEW
ROOF HATCH OPENING.
MODIFY EXISTING AS NOTED
DEMO EXISTING ACT AND GRID
EXISTING ACT AND GRID TO REMAIN
DEMO EXISTING GYP/PLASTER CEILING
EXISTING GYP/PLASTER CLG TO REMAIN
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:2
P
M
D-102
DEMO RCP - OVERALL
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/16" = 1'-0"D-102
1 2ND FLOOR RCP-DEMO PLAN
4A 5 61 2 3 7 8 10 129 114
13 14 15 16 1817
A
B
C
D
F
H
M
L
K
J
I
G
E
A-210
A-210
A-210
A-210
(N) SKYLIGHT ABOVE, TYP
(E) SKYLIGHT ABOVE, TYP
A-2
16' - 4"
7' - 0"
12' - 2"
NW QUAD
OFFICE
OFFICE
OFFICE
OFFICE
CONF.
OFFICE
OFFICE
MEETING
MEETING
MEETING
MTG/OFFICE
MUD RM
NORTH COVERED PATIO
TEL
SPRINKLER
MEN
223.A
WOMEN
223.B
KITCHEN
224.A
ELECTRICAL
224.C
QUIET
224.B
SOUND BOOTH
NE QUAD
OFFICE
SERVER
OFFICE
OFFICE
OFFICE
OFFICE
NE
OFFICE
OFFICE
OFFICE
MEETING
CONF.
STORAGE
PRINT & SUPPLY
OFFICE
HALL
COUNTER
201.B
COUNTER LOBBY
201.A
CUSTODIAL
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
WC VEST
211.A
WOMEN
211.B
MEN
211.C
CONF.
CENTRAL CORRIDOR
CENTRAL CORRIDOR
CENTRAL CORRIDOR
LIBRARY MTG
LIBRARY CONF
LIBRARY
GYM
254.A
QUIET
SECURITY
250.C
FACILITIES
250.A
OFFICE
250.B
CONF.
MULTI - PURPOSE
252.A
GYM VESTIBULE
254.B
STORAGE
254.C
W LOCKER
255.A
M LOCKER
256.A
STOR.
CUSTODIAL
ENTRY VESTIBULE
259.A
ALT. COMMUTE
259.B
MEETING
OFFICE
OFFICE
OFFICE
RADIO
ELECTRIC
SE - IT / FINANCE
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
STORAGE
OFFICE
OFFICE
SE - HR SUITE
OFFICE
OFFICE
OFFICE
OFFICE
OFF/MTG FLEX
NOTE: SEE FINISH PLANS FOR
FLOORING REPLACEMENT, SEE
RCP FOR CEILING REPLACEMENT,
AND SEE MEP FOR LIGHTING AND
HVAC REPLACEMENT.
A-2
A-5
A-5
A-5
1/16" = 1'-0"A-110
1 2ND FLOOR PLAN - OVERALL
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:2
P
M
A-110
MAIN LEVEL PLAN -
OVERALL
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
4A 5 61 2 3 7 8 10 129 114
13 14 15 16 1817
A
B
C
D
F
H
M
L
K
J
I
G
E
REMOVE (E) ROOF AND REPLACE WITH
NEW, SINGLE-PLY MEMBRANE ASSEMBLY.
SEE ESTIMATE NARRATIVE.
(E) SKYLIGHTS
(E) SKYLIGHTS
(E) SKYLIGHT (E) SKYLIGHT
A-210
ALT 3: (13) NEW (SK-1)
SKYLIGHTS - SEE WINDOWS
& DOORS SHEET.
10' - 6"
/4
/4
5' - 9 1/4" 9' - 6 1/2" ± 8' - 8 1/4"
25' - 5 3/4" 16' - 6 1/2" 16' - 6 1/2"
/4
/4
/4
/4
± 6' - 9" 16' - 0"
A-210
A-210
A-210
/4
(E) ROOF HATCH
TO REMAIN
NEW ROOF ACCESS HATCH
ALT 3: (18) NEW (SK-2)
SKYLIGHTS - SEE DOORS
& WINDOWS SHEET.
± 1' - 4 1/2"
/4
2' - 3 1/2"
MIN
4' - 0"
(E) ROOF HATCH
TO REMAIN
ALT 3: (8) NEW (SK-1) SKYLIGHTS -
SEE WINDOWS & DOORS SHEET.
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:2
P
M
A-111
ROOF PLAN - OVERALL
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/16" = 1'-0"A-111
1 ROOF PLAN
4A 6 8 10 12
A
B
C
D
F
E
A-6
-N W
A-6
-N
A-6
-N
A-6
-N21
A-6
-N E
A-6
-N
A-6
-N E5
A-6
-N
A-6
-N E
A-6
-N
A-6
-N
NW QUAD
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
KITCHEN
224.A
ELECTRICAL
224.C
MEN
223.A
WOMEN
223.B
SPRINKLER
TEL
OFFICE
OFFICE
OFFICE
STORAGE
PRINT & SUPPLY
OFFICE
CONF.
MEETING
OFFICE
OFFICE
OFFICE
HALL
CUSTODIAL
CONF.
OFFICE
OFFICE
OFFICE
OFFICE
MTG/OFFICE
MEETING
MEETING
MEETING
NW QUAD
CONF.
OFFICE
SERVER
NE QUAD
NE QUAD
OFFICE
COUNTER LOBBY
201.A
COUNTER
201.B
QUIET
224.B
NORTH COVERED
PATIO
MUD RM
SOUND BOOTH
TV-2
22' - 0" 6' - 0"
36' - 3" 48' - 0" 48' - 0" 48' - 0"
11' - 10"
14' - 0"
2' - 6"25' - 1"2' - 6"
/8
/8
13' - 11"
6' - 0"
22' - 0" 5' - 1"
5' - 6" 23' - 9"
TV-1
TV-1
TV-2
TV-2
5' - 3" 21' - 11"
/8
7"
4' - 9" 6' - 1 5/8"
/8
10' - 1"
8' - 5"
23' - 10 7/8"
2 5/8" 21' - 4 5/8"
23' - 5 5/8"
13' - 8"
A L
IG
N
ALIGN
A L
IG
N
A L
IG
N
211.B-1
0-
9-
8-
220-1218-1
219-1 221-1 222-2
222-1
5-
6-
7-
224.B-1
0-
1-
226-1
2-
228-1 201.B-1
229-1
6-
TV-1
0-
PRINT EQUIP FOR
REF. ONLY. OFOI
ALT 1: NEW THERMALLY
BROKEN, ALUMINUM
WINDOWS WITH STRUCTURAL
STRONGBACK AND FURRED
INTERIOR WALL
WINDOW R.O. = 3'-4"W X 6'-0"H
S1 0 4
S1 0 4
A-402-N
A-402-N
A-401-N
A-330
A-330
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4S2A
0 4
S2A ^ 4
A L
IG
N
8' - 0"
LOCKERS
BIKE RACK 1
18' - 0"
10' - 8" 10' - 8" 18' - 6"
" 3
/4
/2 "22
7' - 11 3/8"
16' - 9"
PARTITIONS TO B.O. DECK
S2A 0 4
S2A 0 4
S2A 0 4
S2A 0 4
S2 0 4
S2A 0 4
S2 0 4
S2A 0 6
S2A 0 4
S2A 0 4
S2A 0 4
PARTITION ABOVE SF
UP TO B.O. DECK, TYP
S2A 0 4
S2A 0 4
S1 0 4
S1 0 4
4-
BIKE RACK 2
8-
A-602-NW
A-6
-N
A-6
-N
TV-1
TV-1
A-6
-N W
A-6
-N W4
A-6
-N W9
A-6
-N E78
A-6
-N
201.A-1
A-4
-N
A-4
-N12
S-2
S-2
A-210
A-210
WC VEST
211.A
WOMEN
211.B
MEN
211.C
DW
MW
R E
F
201.A-2
211.C-1
A-330
DF-1
(N) ROOF
ACCESS
LADDER
W/
HATCH,
ABOVE
(E) SD CHASE, VIF
(E) SD CHASE, VIF
S2A 0 4
MATCH (E) ADJACENT WALL
THICKNESS AND HEIGHT
S2A 0 4
MATCH (E) ADJACENT WALL
THICKNESS AND HEIGHT
S2
INF
S2
INF
S2
INF
S2
INF
M
IN
C L R
(2) MICROWAVES -
SEE ELEVATION:
/19 A-601-N
IS-1A
IS-1B
IS-2A
IS-2D
IS-2C
IS-2B
IS-5A
IS-5BIS-4
IS-5
S-1
CEILING LINE
FLOOR
B.O. STRUCTURE
- ^ + 0 1 2 S
FIRE RATING / PARTITION HEIGHT DESIGNATION
- : PARTIAL HEIGHT PARTITION. SEE PLAN AND ELEVATIONS FOR SPECIFIED HEIGHT
^ : NON RATED TO B.O. CEILING
+ : NON RATED. EXTEND STUDS TO B.O. STRUCTURE ABOVE.
EXTEND GYP BOARD 2" ABOVE TOP OF CEILING U.N.O.
0 : NON RATED. EXTEND STUDS TO B.O. STRUCTURE ABOVE.
EXTEND GYP. BOARD BOTH SIDES TO B.O. STRUCTURE ABOVE U.N.O.
1 : (1) HOUR FIRE RATED ASSEMBLY
2 : (2) HOUR FIRE RATED ASSEMBLY
S : SMOKE PARTITION
KEY
NOTE: NO FIRE RATED
ASSEMBLIES IN PROJECT.
PARTITION
TYPE
FIRE RATING /
PARTITION HEIGHT
DESIGNATION
STUD FRAMING /
CMU SIZE
DESIGNATION
INTERIOR PARTITION TYPE TAG
LOCATION OF TAG
INDICATES SIDE OF
WALL TO RECEIVE
ADDITIONAL LAYERS
OF GYP WHEN
INDICATED BY THE
PARTITION TYPE
(EXCEPTION: SHAFT
WALLS SH1 & SH2
TAGGED @
SHAFTLINER SIDE OF
WALL)
WALL TYPE
EXTERIOR WALL TYPE TAG
PARTITION HATCHES
FLOOR PLAN NOTES - WALL TYPES
1. COORDINATE WALL TAGS IN DRAWINGS WITH
CONFIGURATIONS ILLUSTRATED ON ASSEMBLIES SHEET.
2. SEE FINISH SCHEDULE FOR WALL AND CEILING FINISHES. SEE
INTERIOR ELEVATIONS AND FINISH SCHEDULE FOR TILE
EXTENTS.
3. DIMENSIONS ARE TO THE FACE OF STRUCTURE (STUD /
CONCRETE) U.N.O..
4. AN "INF" FRAMING SIZE DESIGNATION INDICATES INFILL WALL
FRAMING, TO MATCH EXISTING ADJACENT WALL THICKNESS AND
HEIGHT IF APPLICABLE.
XXA
XX
SHEAR PANEL (RED) RESILIENT
CHANNEL (BLUE)
RSIC-1 (BLUE)
WALL LAYERS
EW1
1. PARTITION WALL TYPES THAT END WITH AN "A" DESIGNATION,
ARE ACOUSTIC WALLS.
2. THESE ARE NOTED VISUALLY IN PLAN WITH A HEX
CROSSHATCH.
3. IF RATED, THE WALL SHOWS BOTH ACOUSTIC HATCH AND FIRE
RATING FILL.
1HR RATED WALLS HAVE A BLUE FILL.
2HR RATED WALLS HAVE A YELLOW FILL.
3HR RATED WALLS HAVE A PURPLE FILL.
XXA
XX 1
XXA
XX 2
XXA
XX 3
XXA
XX
GENERAL NOTES - FLOOR PLANS
1. DIMENSIONS ARE TO FACE OF FRAMING / MASONRY / CONCRETE U.N.O.
2. SEE FINISH SCHEDULE FOR WALL AND CEILING FINISHES. SEE INTERIOR
ELEVATIONS AND FINISH SCHEDULE FOR TILE EXTENTS.
3. REFER TO REFLECTED CEILING PLANS FOR SOFFIT AND TOP OF WALL
CONDITIONS.
4. MATCH EXISTING WALL THICKNESS AT INFILL FRAMING LOCATIONS.
LEGEND - FLOOR PLANS
EXISTING TO REMAIN NEW WALL NEW DOOR, EXISTING WALL
TO REMAIN
RBA #:
SET ISSUE
P.I.C:
PM / PA:
DATE
STAMP
REV. DATE
REVISIONS TO THIS SHEET
Owner
Project Name
Project Address
PROJECT TRACKING
City of Springfield
DESIGN DEVELOPMENT 2025-08-18
NOT FOR CONSTRUCTION
DESCRIPTION
KEY PLAN
75%CD / COSTING SET 2026-03-26
/2
/2
:0
:2
P
M
A-120-N
DIMENSION PLAN -
NORTH
225 5th St, Springfield, OR 97477
SPRINGFIELD QUAD
REMODEL
BRITNI JESSUP
KARA STRICKLAND
1/8" = 1'-0"A-120-N
1 DIMENSION PLAN -…