Attachment 9 - Appendix B2 - Asbestos Report.pdf

PDF 150 KB Posted

Attached to
636-130 - Expand and Remodel Lab - Minor - Des Moines, IA VACIHCS
Solicitation number
36C77625B0043_1
Issued by

About this file

This document is an Asbestos-Containing Material (ACM) Assessment Database for the VA Central Iowa Health Care System's Building 3 Modular Addition project in Des Moines, Iowa, dated July 14, 2020. The assessment covers multiple floors and spaces, identifying potential asbestos-containing materials and their characteristics.

The report indicates minimal ACM presence, with only one location showing a black/gray tan material (10 linear feet) above a door into Building 3. Other entries include two fire doors and two electric panels, all marked as "Assumed" for potential asbestos content. The materials are generally in good condition with low disturbance potential, spanning locations such as the roof, exterior, crawlspace, large room, and furnace room. The document provides detailed categorization including floor, functional space, location, material type, description, quantity, height, condition, and disturbance potential.

View the file

Other files

File Type Posted
RFI Responses - Des Moines VACIHCS 8-20-25.xlsx XLSX spreadsheet
S06 - Amendment 0004 36C77625B0043_1.pdf PDF
Attachment 14 - Pneumatic Tube Location Drawing.pdf PDF
S06 - Amendment 0003 36C77625B0043_1.pdf PDF
RFI Responses - Des Moines VACIHCS 8-19-25.xlsx XLSX spreadsheet
Attachment 2 - Davis-Bacon Act WR - Polk Ctny - Rev09 - 8-8-25 - Building.pdf PDF
S06 - Amendment 0002 36C77625B0043_1.pdf PDF
RFI Responses - Des Moines VACIHCS 8-7-25.xlsx XLSX spreadsheet
Attachment 13 - Narrative - Addendum 1 and drawings.pdf PDF
Attachment 2 - Davis-Bacon Act WR - Polk Ctny - Rev08 - 7-25-25 - Building.pdf PDF
S06 - Amendment 0001 36C77625B0043_1.pdf PDF
S04 - Site Visit Sign-in Sheet 636-130 - Des Moines 7-22-2025.pdf PDF
Attachment 3 - Site Visit Instructions - Minor Lab Expnd and Remod - VACIHCS.pdf PDF
36C77625B0043_1 - Des Moines VACIHCS - Expand and Remodel Lab_.docx DOCX document
Attachment 1 - VA Notice of LOS-Cert of Compliance for Construction.docx DOCX document
Attachment 4 - 15569-Bid Documents-R1 - 5-29-2025.pdf PDF
Attachment 7 - Appendix A - Geotechnical Engineering Report.pdf PDF
Attachment 8 - Appendix B1 - Pre-demolition Hazardous Materials Survey.pdf PDF
Attachment 11 - 636-130 PCRA LAB_executed.pdf PDF
Attachment 2 - Davis-Bacon Act WR - Polk Ctny - Rev06 - 6-27-25 - Building.pdf PDF
Attachment 5 -15569-Spec Vol I-R2 - 6-23-2025.pdf PDF
Attachment 6 - 15569-Spec Vol II-R1 - 5-29-2025.pdf PDF
Attachment 10 - Appendix B3 - Lead Paint Report.pdf PDF
Attachment 12 - Brand Name Justification - Des Moines VACIHCS - Redacted.pdf PDF
Show all 24

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7/14/2020 VA CENTRAL IOWA HEALTH CARE SYSTEM - BUILDING 3 MODULAR ADDITION

DES MOINES, IOWA

ASBESTOS-CONTAINING MATERIAL ASSESSMENT DATABASE

Floor

Functional

Space Location Type Description Quantity

Height

(Feet) Condition

Disturbance

Potential

Homog.

Material

Roof 1 Roof No ACM Observed

1 2 Exterior No ACM Observed

-1 3 Crawlspace No ACM Observed

1 4 Large Room MISC Black/Gray tan (above door into Building 3) 10 lf 8 G L 20

1 4 Large Room MISC Fire Door (Curries - 1.5 hour rated) 1 door 0-7 G L Assumed

1 4 Large Room MISC Fire Door (Warnock Hersey - 1.5 hour rated) 1 door 0-7 G L Assumed

1 5 Furnace Room MISC Electric panels 2 panel 4-6 G L Assumed

Type: TSI=Thermal System Insulation SURF=Surfacing Materials MISC=Misc.

Quantity: CF=Cubic Ft LF=Linear Ft SF=Square Ft Condition: G=Good F=Fair P=Poor Dist. Pot.: L=Low M=Medium H=High