Attachment 8_Standard_Operating_Procedures.docx

DOCX document 18 KB Posted

Attached to
PACNORWEST Turn Key live-fire Fire Fighting and Damage Control Training
Solicitation number
N6134022B0001
Issued by

View the file

Other files

File Type Posted
SF 1409.pdf PDF
Attachment_0009_QandA_v2.xlsx XLSX spreadsheet
N6134022B0001_AMD02.pdf PDF
Attachment_0001 - Amend 2_PNW Competitive Effort Performance Work Statement_10MAY22.doc DOC document
N6134022B0001_AMD02_CONFORM.pdf PDF
Attachment_0009_Question_and_Answer.xlsx XLSX spreadsheet
Attachment_0010-GFP Fire Sanitation Cabinet Owners Manual.pdf PDF
Attachment_0011_SOP_GFP_Sanitation_Cabinet.docx DOCX document
N6134022B0001_AMD01.pdf PDF
Attachment_0007_GFP_List_5.02.22.xlsx XLSX spreadsheet
Attachment_0001 - Amend 1_PNW Competitive Effort Performance Work Statement_05MAY22.doc DOC document
N6134022B0001_CONFORM_AMD01.pdf PDF
Attachment 4 Wage Adjustment Baseline Form.xlsx XLSX spreadsheet
CDRL A006- Technical Report_PACNORWEST.docx DOCX document
CDRL A008- QSP_PACNORWEST.docx DOCX document
Attachment 6 NETCINST 1500.13C (NETC High and Moderate Risk Training Safety Program).pdf PDF
Attachment 5 (TCCD) A-495-0018A Shipboard Firefighting Integrated Team Trainer.pdf PDF
Attachment 5 (TCCD) A-495-0416B General Shipboard Firefighting-(SCBA).pdf PDF
N6134022B0001.pdf PDF
CDRL A001 - Monthly Reports_PACNORWEST.doc DOC document
PWS Attachment 1 HRTSE Checklist and Firefighting Checklist.pdf PDF
Attachment_L1_PACNORWEST_Bid_Price.xlsx XLSX spreadsheet
CDRL A005 - Structural Integrity Survey_PACNORWEST.doc DOC document
Attachment 2 Data Item Transmittal (DIT) Form 4330.pdf PDF
Attachment 5 (TCCD) K-495-0045B General Shipboard Damage Control Training.pdf PDF
Attachment 5 (TCCD) J-495-0419B Advanced Shipboard Firefighting.pdf PDF
Attachment 5 (TCCD) A-495-0021 Shipboard Firefighting Damage Control Emergency Team Trainer.pdf PDF
CDRL A003 - Conference Minutes_PACNORWEST.doc DOC document
Attachment 3 DOL Wage Determination 15-5536 Rev 12 061020.pdf PDF
Attachment 7 GFP 071420 Final.xlsx XLSX spreadsheet
CDRL A002 - Contractor Operation and Mainentance of TSG_GFE Management report_PACNORWEST.doc DOC document
CDRL A007- Mishap Investigation and Reporting_PACNORWEST.docx DOCX document
CDRL A004 - Facility Modifications_PACNORWEST.doc DOC document
Attachment 1 - PNW Competitive Effort Performance Work Statement - signed.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Required SOPs 26 May 2021 Backup communications systems tested prior to start of training day Provide the emergency signal/procedure part of student indoctrination Provide procedures demonstrating preventative maintenance on air compressor Provide daily startup procedures for all trainers Provide daily shutdown procedures for all trainers Provide the initial equipment setup/startup and readiness processes for: DORT

a. Water supply alignment

b. Emergency extinguishing system checks

c. Placement and check of emergency equipment

d. Electrical system check*

e. Drainage alignment check

f. Emergency alarm check*

g. Ventilation system alignment *

h. Fuel supply alignment *

i. Communications checks * [Ref (a), Encl 1, 1.a(1) - (9)(a)-(b)]

* Not required for 19F/21C12 trainers. [Ref (a), Encl 1, 1.a(1) - (9)(a)-(b)]

Provide the process for each fire scenario for:

a. Initial preparations

b. PPE worn by instructors and students

c. Number of instructors, facilitators and safety observers; includes positions and duties

d. Ventilation, if mechanical

e. Fueling system activation and securing *

e. Ignition system activation and securing *

f. Instructor/facilitator rotation procedures

g. Securing procedures after final fire

* Not required for 19F/21C12 trainers.

[Ref (a), Encl 1, 1.b(1- 8)]

Provide the processes for facility/equipment shutdown and securing including:

a. Ignition system alignment and securing *

b. Fuel system alignment and securing *

c. Ventilation system alignment and securing *

d. Electrical power*

e. Water system alignment and securing

f. Storage of extinguishers, hoses, burn pots, etc.

g. Cooling of structures

h. Wash-down and drainage

i. Fuel systems

* "Instrument Power/24 Hour Mode" for 19F/21C12 trainers [Ref (a), Encl 1, 1.c(1)(a)-(d) and 1.c(2)(a)-(e)]

Provide the process for propane refueling procedures, including:

a. Safety precautions

b. Operating Procedures (including approval authority)

c. Emergency Procedures (including propane leaks)

d. Notification of base Emergency Services [Ref (a), Encl 1, 1.d(1 - 4)]

Ref (a) NETCINST 1500.16A, Firefighting Training Safety Program Ref (b) NFPA 1403, Standard on Live Fire Training Evolutions Ref (c) NFPA 1402, Guide to Building Fire Service Training Centers Ref (d) NETCINST 1500.13C, NETC High and Moderate Risk Training Safety Program