This document is a request for an alternate method approval related to a federal contract opportunity for construction of the Sloan Canyon Contact Station. The Bureau of Land Management Southern Nevada District Office is seeking to reduce the required fire flow for the 3,000 square foot facility from 1,500 gallons per minute for 2 hours as specified in the 2018 International Fire Code, to 1,500 gallons per minute for 13 minutes (19,500 gallons total) in accordance with NFPA 1142 based on an analysis classifying the occupancy hazard level 4 and construction type V-B with no exposures. Short Elliott Hendrickson Inc. as the delegated designer recommends approval due to the provision of an automatic sprinkler system designed to NFPA 13 standards to provide 300 gallons per minute for 30 minutes (9,000 gallons), along with a fire pump and over 28,500 gallon water tank to supply both the sprinkler system and a hydrant for fire department use.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
City of Henderson Building and Fire Safety Department
240 Water Street P.O. Box 95050 Henderson, Nevada 89009-5050
Bldg (702) 267-3650 FS (702) 267-3630 Fax (702) 267-3603
REQUEST FOR ALTERNATE METHODS
Building & Fire Safety Rev 07/07
BFSE 0400
04/08
BAMM T200
PROVIDES EQUIVALENCY
Date:
Project Name:
Project Address:
Owners Name:
Owners Address:
INTRODUCTION:
Type of Construction: Occupancy Classification:
Number of Stories: Size of Building: square feet Sprinkler - Hazard Classification: Design Density:
Permit Number(s) to be referenced:
REQUEST:
Code and Code Section Affected:
Code Edition: Code Title:
Section Number: Section Title:
Code Requirement:
Alternate Being Requested:
APPROVED DISAPPROVED
14 January 2021 Sloan Visitor Contact Station
U.S. Government; Bureau of Land Management BLM - Southern Nevada District Office, 4701 North Torrey Pines Drive, LV, NV 89130
V-B, 000 A-3, 3,0031
Light Light; 0.1/1500 N/A
2018 IFC International Fire Code B105 FireFlow Requirements for bldgs
The minimum fire-flow and flow duration for buildings other than one- and two-family dwellings, Group R-3 and
B105.1(2). Per Table B105.1(2) Column V-B row 0-3,600 sq.ft. the required fire flow is 1,500 gpm for a 2-hours duration.
Instead of using the 2018 IFC appendix B to determine the fire flow use the 2017 edition of NFPA 1142.
NFPA 1142 is the Standard on Water Supplies for Suburban and Rural Fire Fighting. The facility has been analyzed per NFPA 1142 section 4.1.1 as follows: Occupancy hazard 4 Exhibition Halls, Construction type 000 (V-B); dimensions 81’ length 44’ width and 16’ height; with no exposures. The water supply to be provided is an underground water tank with a fire pump to 1 hydrant with a minimum fire flow of 1,500 gpm for at least 13 minutes duration (19,500 gallons).
mark.sandusky@cityofhenderson.com Text Box
BOTH2021137357
mark.sandusky@cityofhenderson.com Ellipse
REQUEST FOR ALTERNATE METHODS
BFSE 0400
Rev 07/07
JUSTIFICATION: (Provide supporting data, technical reports, data sheets, modeling, calculations, sketches, drawings, etc. Attach as separate sheets as necessary)
SUBMITTED BY: (If prepared by a registered professional provide a “wet seal”)
Signature Date
Name Title Company Name:
Company Address:
Company Telephone: Fax:
Owner’s (Authorized Representative) acknowledgement of this request:
Signature Date
Name Title Company Name:
Company Address:
Company Telephone: Fax:
DETERMINATION: (Mark check box on page one)
Reviewed By:
Name Title Date
Conditions of approval
MITTETETETTETETETETETETETETTETETTETTTETTTTTTTETETTTTTTETETETETETTTTETTTTTETETTTTTETTTTETETETTETTTETETETTETETETTTTETETETTETTETTETETTTTETTTETTTTTTETTTTTTEETTTTETETTTTEEETTTTTEEETTTTTEETTTTEEETTTTETTTEEETTTTTEETTTEEETTETTTETTTTEETTTEETEEETTTTEEEEEETTTTTEEEEETTTTEEEEEETTTTTEEEEETTTEEEDDDDDDDDDDDDDDDDDDDDDDDDD BY: (I((((((((( f prepared atttttttttttttttttttttttttttttttttttttttttttttttttttttuuuuuururururuuuuuuururuuuuuuruuuuuuuruuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuuu e l provide a “wet seal”) e
This building is not required by code to be provided with an automatic fire sprinkler system. The owner has elected to provide an automatic fire sprinkler system designed in accordance with NFPA 13. The required fire flow is allowed to be reduced when a building is provided with an automatic sprinkler system. This system mitigates the required fire flow and provides life and property protection to the facility, assisting the firefighters.
The sprinkler system will be designed to provide 300 gpm for 30 minutes (9,000 gallons). The overall system will include a single tank with more than 28,500 gallon capacity and a pump system for fire flow to the hydrant and sprinkler flow to the building.
Short Elliott Hendrickson, Inc.
2000 S Colorado Blvd Colorado Tower 1 Ste 6000 Denver CO 80222
720.540.6800
James D. Hayson, PE Senior Professional Engineer II
04/07/2021
Raymond Tsui District Civil Engineer
Bureau of Land Management, Southern Nevada District Office 4701 North Torrey Pines Drive, Las Vegas, NV 89130
(702) 515-5039
April 7, 2021 mark.sandusky@cityofhenderson.com Fire Approval - 2 mark.sandusky@cityofhenderson.com Text Box Mark R Sandusky mark.sandusky@cityofhenderson.com Text Box Senior Fire Safety Plans Examiner
| 2021-04-07T17:39:11-0700 | |
| RAYMOND TSUI |
File details come from the government source that posted it. Updated .