This is a Johns Manville (JM) technical specification document for a 2-ply SBS bonded roofing system applied to insulation. The specification details approved materials and application methods for commercial and industrial roof installations over various structural substrates including steel, structural concrete, and nailable decks (wood, gypsum, cementitious wood fiber, and lightweight insulating concrete).

The system comprises multiple component layers with specific material options: approved base plies (DynaBase, DynaLastic, PermaPly, GlasTite, and DynaMax products in cold-applied format), optional vapor barriers and thermal barriers with specified thicknesses, approved cover boards when applicable, JM insulation products (DuraFoam, ENRGY 3 with PSI options, CGF, and tapered Fesco Board with three customizable thickness layers), and cap sheets using polyester-reinforced cool roof technology (DynaLastic 180 FR CR and 250 FR CR variants) applied cold adhesive. Installation requires proper deck preparation, specific lap requirements (4-6 inches depending on material type), and asphalt primer application where required. The specification document includes assembly identification coding, material compatibility matrices keyed to application methods (cold adhesive, hot asphalt, heat welded, self-adhered), and references JM technical services and guarantee requirements documentation for detailed installation guidelines and warranty specifications.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Base Ply (Cold Applied):

DynaBase DynaBase PR DynaBase XT DynaLastic 180 S DynaLastic 250 S DynaPly T1 PermaPly 28 GlasTite Plexible DynaMax™Smooth

Deck Type:

Steel (22 Ga. Min.)

Structural Concrete Nailable Decks include:

Cementitious Wood Fiber Gypsum Lightweight Insulating Concrete Wood (Plywood, Plank, OSB)

Approved Vapor Barrier:

(If Applicable) DynaBase (CA) (HA) DynaBase PR (CA) (HA) GlasPly IV (HA) GlasPly Premier (HA) APPeX 4S (HW) DynaWeld™Base (HW) DynaBase HW (HW) DynaWeld 180 S (HW) JM APP™Base Sheet (HW) DynaGrip Base SD/SA (SA) JM BaseGrip™ SD/SA (SA) JM Vapor Barrier SA (SA) 6 or 10 mil poly with taped seams

Approved Thermal Barrier:

(If Applicable)

JM SECUROCK

Gypsum-Fiber Roof Board Glass-Mat Roof Board

JM DEXCELL

FA Glass-Mat Roof Board Glass-Mat Roof Board JM DensDeck JM DensDeck Prime DuraBoard Thermal Barrier Thickness _____

Approved Base Sheets:

(If Applicable) Over Nailable Deck DynaBase DynaBase PR DynaBase XT DynaFast 180 S DynaLastic 180 S DynaLastic 250 S GlasBase™ Plus GlasPly Premier GlasTite Flexible PermaPly 28 Ventsulation Felt

Approved Cover Boards: (If Applicable) 1/2" RetroFit™Board (HA) DuraBoard (CA) (HW) Fesco Board (HA) Fesco Board HD (HA)

JM DEXCELL

FA Glass-Mat Roof Board (CA) (HW) (SA)

JM SECUROCK

Gypsum-Fiber Roof Board (CA) (HA) (HW) (SA) JM DensDeck Prime (CA) (HA) (HW) (SA) RetroPlus™Roof Board (CA) (HA) ProtectoR™ HD Cover Board (CA) (SA) SeparatoR CGF Recover Board (CA) (SA) Cover Board Thickness _____

Approved JM Insulations:

DuraFoam

ENRGY 3

(ENRGY 3 Options)

CGF

20 PSI

25 PSI

Tapered Tapered Fesco Board Layer 1 Thickness _____ Layer 2 Thickness _____ Layer 3 Thickness _____

Vapor Barrier Application Key (CA) Cold Applied (HA) Hot Asphalt (HW) Heat Weld (SA) Self Adhered

For JM Guarantee Requirements Contact JM Technical Services at (800) 922-5922 Option 3 or Refer to the JM Peak Advantage Charges and Requirements-Multi Ply document

2Number of Plies

Cap Sheet Application Method CA = Cold Adhesive HA = Hot Asphalt HW = Heat Welded SA = Self Adhered

Cap Sheet C = Composite F = Fiberglass P = Polyester

Surfacing D = SBS Cap Sheet (Granule Surface) CR = Mineral Surfaced Cool Roof Sheet

Assembly Identification Substrate I = Insulated I D

-CR

Cap Sheet - Cold Applied (Polyester Reinforced - Cool Roof):

DynaLastic 180 FR CR DynaLastic 180 FR CR G DynaLastic 250 FR CR DynaLastic 250 FR CR G

P -CA

Cover Board Membrane Compatibility and Application Key (CA) Cold Applied (HA) Hot Asphalt (HW) Heat Weld (SA) Self Adhered

Wood Deck

Insulation

Cover Board Approved

Insulation or Cover Board

(if req'd.)

F ull S heet

Asphalt Primer if

Required

Drainage

4" End Lap

" Side Lap

Approved JM

Bituminous

B ase PlyFull S heet

4" End Lap

6" for Polyester

Approved JM

Bituminous

C ap Sheet

" Side Lap

1/2 Sheet

RS-1719 04-22 (Replaces 03-21)