Attachment 7 - As Built Record EHRM_Part II (1).pdf
PDF 10 MB Posted
- Attached to
- 656-26-702 EHRM DDPO 2. 0 Federal contract opportunity
- Solicitation number
- 36C26326B0028
About this file
These are record drawings prepared for the VA Medical Center in St. Cloud, Minnesota, documenting the EHRM Infrastructure Upgrades project (656-21-235). The drawings include electrical, mechanical, and telecommunications systems across basement, first floor, second floor, and roof levels, showing both demolition and remodel work. The document is dated March 30, 2022 (100% Construction Documents phase) with record document updates through June 21, 2024, based on contractor-provided markups during the construction phase.
The electrical drawings depict power distribution systems including switchboards (MSB-1A, SWBD LS, SWBD EQ), panels (B01IT-1 through B01IT-3), automatic transfer switches (ATS), and branch circuitry for lighting, receptacles, and specialized loads across multiple building areas. Mechanical drawings show HVAC equipment relocation and installation, including ductless cooling units (AC-1-1 through AC-1-4), cabinet unit heaters, hydronic piping systems, condensate drainage, thermostat controls, and refrigerant routing from basement to roof-mounted condensing units. Telecommunications drawings document structured cabling infrastructure with limits of data cabling, rack locations in telecom rooms (A05C, A200, 005E, 005F), wireless access points (WAP), and associated conduit requirements. The drawings include detailed keyed notes regarding existing conditions to be verified prior to bidding, field coordination requirements, and specific installation procedures. All drawings are signed by licensed Minnesota engineer Alexander S. Quast (License #53095) and prepared under the direction of Anderson architects/engineers.
View the file
Other files for this federal contract opportunity
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
52.1183
36.0000
" X
C
O N
FE
R
E N
C E
T A
B
LE
W / 1
E
R G
O C
H A
IR
S
PROXMIA
48" FLAT
SCREEN
TELEVISION
AEC
CB1
DACC
GAC
LCC
CR
L
R
ELEV
ELEV
UNEXCAVATED
HAC
ASB
STAIR
A05B
STORAGE
C0-B4
CORR
C0-B3
CORR
A05A
MECHANICAL
C0-B2
CORR
A01
HAC
A06
ELECTRICAL
C0-B1
CORR
A02
EQUIP
ELEV
E-A1
ELEV
A10
SPACE
MECH
OFFICE
30A
MECH26
STAIR
STOR 28
OFFICE
C0W
CORR
OFICE
CLOSET
38A
BATH
CHANGE
ROOM 2
X-RAY
37A
EQUIP
PROCESSING
FILM
MECH
ROOM 1
X-RAY
33A
EQUIP
WAITING
EXAM
32A
TOILET
SOUND
ULTRA
IMAGING
MECH22
EXAM24
STAIR
18A
MECH
19A
MECH
ELEC
MECH
ELEC
LOBBY
MECH
12A
ELEC
HEATER
WATER
OFFICE
HAC
PHONE
WAITING
2B
WOMEN
TOILET
4C
LOCKER
MALE
OFFICE
C0N
CORR
C0C
CORRIDOR
HAC
10B
OFFICE
10A
OFFICE
OFFICE
STAIR
4A
LOCKER
FEMALE
LOUNGE
STAFF
4B
TOILET
STOR
8I
MECH
5A
CLOSET
OFFICE
PHYSICIAN
5E
OFFICE
PHYSICIAN
5C
CORR
5D
MECH
5B
MECH
36A
CHANGE
CORRIDOR
36B
TOILET
36C
CT SCANNER
36D
CONTROL
36E
EQUIPMENT
2A
MEN2C
RECEPTION
RT CLINIC
ABG LAB/
PFT LAB45
HAC
LAB CLASSROOM
APAP/CPAP
EKG LAB
53A
STORAGE
CONCENTRATOR
EDUCATION
RT CLINIC/
SOILED
CP
WORKROOM
STAFF
STORAGE
PROSTHETICS
OFFICE
EKG LAB
A60
OFFICE
A61
OFFICE
A62
OFFICE
A59
STORAGE
SUPPLY
A63
HEMA/COAG
CHEM/URINE/
A67
LOUNGE
CONF./
A68
BANK
BLOOD
A64
MICROBIOLOGY
A56
RECEP.
A58A
DRAW
PHLEB.
A58B
DRAW
PHLEB.
A58C
DRAW
PHLEB.
A58H
DRAW
PHLEB.
A58I
DRAW
PHLEB.
A58J
DRAW
PHLEB.
A58G
DRAW
PHLEB.
A58D
DRAW
PHLEB.
A58K
DRAW
PHLEB.
A58F
DRAW
PHLEB.
A58E
DRAW
PHLEB.
A57A
TOILET
A57B
TOILET
A57C
TOILET
A57
COLLECTION
A66
LOCKER
A65
TOILET
C0-B1
WAITING
C0-H1
CORR
C0-H5
CORR
C0-C2
CORR
C0-H2
CORR
C0-H4
CORR
C0-H3
CORR
A58
PHLEB
A58
PHLEB
C0-H6
CORR
C0-H7
CORR
30B
OFFICE
30C
OFFICE
8D
EQUIP
8A
MRI
7F
INTAKE
7E
INTAKE
7D
HAC
7C
TOILET
7B
CHANGING
7A
CHANGING
8H
VESTIBULE
7G
FOYER
COE
CORRIDOR
8C
HALL
8B
CONTROL
LIEBERT COOLING SYSTEM
01-E300
01-E300
NORMAL (MSB-1), LIFE SAFETY(SWBD LS), CRITICAL (SWBD CR)
EQUIPMENT SWITCHBOARD(SWBD EQ)
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:0
P
M
01-E100
BASEMENT DEMOLITION -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT DEMOLITION - ELECTRICAL
N
0 8' 16'4'
N
0 8' 16'4'
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
e: 03/30/202205-06-2022
RECORD DOCUMENTS
INSIDE dgsf = 26,040 S.F.
STAIR A
RAMP
UP
A -O
-V
STAIR
210A
CORRIDOR
C2EA
STAIR
EXAM
CORRIDOR
C2C
UTILITY
229A
PHONE
ELEVATOR
LOBBY
CORRIDOR
C2N
CORRIDOR
INTAKE
230A
INTAKE
230B
TOILET
230C
EXAM
CORRIDOR
C2W
CORRIDOR
C2CA
SCOPE
STORAGE
STAFF
LOCKER
NURSE
STATION
237A
RECOVERY
WHEELCHAIR
TOILET
MEDS
PATIENT
INSTR
TOILET
235A
PROCTO
PROCEDURE
HOLDING
SOILED
UTILITY
ENDOSCOPY
PROCEDURE
SOILED
LINEN
ENDOSCOPY
PROCEDURE
STORAGE
CORRIDOR
C2WC
CORRIDOR
C2WB
TOILET
UROLOGY
PROCEDURE
TEST/
TOILET
UROLOGY
PROCEDURE
CORRIDOR
C2WA
STAIR
MINOR
PROCEDURE
MINOR
PROCEDURE
HAC
243A
STAIR
243B
CALL
CENTER
NURSING
SKIN
INTEGRITY
210F
EXAM
210E
EXAM
210C
EXAM
210B
EXAM
210A
WAITING
LINEN
210D
CORRIDOR
C2EC
CORRIDOR
C2ED
CORRIDOR
C2EB
EXAM
215D
EXAM
215C
EXAM
215B
EXAM
215A
STORAGE
HAC
PAC
TEL-MED
INTAKE
STAFF
STAFF
LOCKERS
221A
CLEAN
SOILED
BCG
MANAGER
OFFICE
STOR.
WAITING
STAFF
221WAITING
202RECEPTION
PATIENT
TOILET
STAFF
TOILET
ANESTHESIA
OFFICE
A233
ANESTHESIA
WORKROOM
A232
EQUIPMENT
ROOM
A231
SOILED
A230
LOUNGE
A229
CORRIDOR
C2-A7
HALL
C2-A6
HALL
C2-A5
O.R.
A223 O.R.
A222 O.R.
A219
RECOVERY
A213A
CLEAN
A225
HALL
C2-A8
CORRIDOR
C2-A9
SUB
STERILE
A224
CLEAN
CORE
A218
SUB
STERILE
A220
STORAGE
A221
HALL
C2-A4
HALL
C2-A2
HAC
A226
HALL
C2-A11
RAMP
C2-A12
ELECT.
A216
ELEV.
LOBBY
C2-A12
STERILE
SUPPLIES
A217
RECOVERY
A214
RECOVERY
A213B
RECOVERY
A213C
RECOVERY
ISOLATION
A215
HAC
A203
INTAKE
A204
INTAKE
A205
INTAKE
A208
INTAKE
A207
NURSE
A210
HALL
C2-A3
SCHEDULING
A201
HEAD
NURSE
A202
WOMEN'S
LOCKER
A227
SOILED
A212
CLEAN
A211
STAFF
TOILET
A209
PATIENT
TOILET
A206
MEDS
A210A
NOUR
A210B
RAMP
C2-A1
SURGERY
RECEPTION
225A
SURGERY
WAITING
CONSULT
STAIRS
A234
DN
UP
DN
UP
A200
TELECOM
ROOM
TELECOM ROOM
A200
01-E300
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:0
P
M
01-E102
SECOND FLOOR DEMOLITION -
ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
Checker Author
16305
N O R
HT
1/8" = 1'-0"
SECOND FLOOR DEMOLITION - ELECTRICAL
100% CD 03/30
1 UPDATE TO BID DOCUMENTS 06/29
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
E
52.1183
52.1183 36.0000
" X
C
O N
FE
R
E N
C E
T A
B
LE
W / 1
E
R G
O C
H A
IR
S
PROXMIA
48" FLAT
SCREEN
TELEVISION
AEC
CB1
DACC
GAC
LCC
CR
LIEBERT COOLING SYSTEM
A05C
TELECOM
ROOM
005F
TELECOM
ROOM
005E
LOCKER
01-E301
01-E301
01-E301
01-E301
ATS-1-EQ
ATS-1-LS
ATS-1-CR
MB
LRB
EQB4
EQB2
EQB
NORMAL (MSB-1), LIFE SAFETY(SWBD LS), CRITICAL (SWBD CR)
EQUIPMENT SWITCHBOARD(SWBD EQ)
1-LB5
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:0
P
M
01-E200
BASEMENT - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
BASEMENT - ELECTRICAL
N
0 8' 16'4'
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
FRIDGE
24X26
SCALE
COPIER
PRINTER
FR
O
N T
EXAM
CLEAN
UTILITY
EXAM
EXAM
EXAM
MED
152A
STAIR
FEMALE
MALE
STAIR
COPY
RECEPTION
128A
WAITING
CHECK
OUT
128C
ELEVATOR
LOBBY
V.I.C.
128B
EXAM
WHCHR
STOR
EXAM
CLEAN
UTILITY
STAIR
STAIR
PIPE
CHASE
WAITING
STAFF
EXAM
EXAM
PHARM.
CONSULT
EXAM
SOILED
UTILITY
NURSING
EXAM
EXAM
EXAM
NURSE
OFFICE
NURSE/
CHART
INT
EXAM
INT
EXAM
INT
EXAM
INT
EXAM
INT
EXAM
INT
EXAM
MECH
ELEC
177 STOR
SPEC
PROC
CLEAN
UTILITY
160A
INTAKE
TOILET
160B
NURSING
EXAM
EXAM
EXAM
EXAM
EXAM
EXAM
NURSE/
CHART
MED
173A
WAITING
ENTRY
REGISTRATION
REGISTRATION
MAA
CORRIDOR
C1NC
CORRIDOR
C1WA
CORRIDOR
C1WC
CORRIDOR
C1WD
C O
R R
ID
O
R C W E
CORRIDOR
C1WB
CORRIDOR
C1WF
CORRIDOR
C1WG
CORRIDOR
C1WJ
C O
R R
ID
O
R C W H
CORRIDOR
C1WI
INTAKE
173B
PHONE
127A
MECH
EXAM
NURSING
EXAM
PHARM.
CONSULT
A128
WAITING
A101
COMM
TELE-
A102A
WOMEN'S
A103
CONSULT
SHARED
A104
CONSULT
PHARM
A105
CONSULT
PHARM
A106
HAC
C0-2
CORR
A107A
DICTATION
A108
STAFF
A107B
CLOSET
A127A
CHECK-OUT
A126
INTAKE
A127D
MED RM
A127C
STATION
NURSE
A127B
CHECK-IN
A147
STORAGE
A146
EXAM
A124
EXAM
A125
EXAM
A102B
CHASE
A-1
STAIR
C0-4
CORRIDOR
A109
EXAM
A110
OFFICE
A111
VEST
TRIAGE
C0-3
CORRIDOR
A117
TOILET
A118
ALCOVE
NURSE
A120
UTILITY
SOILED
A121
OFFICE
A122
EXAM
C0-5
CORR
A123
EXAMA119
EXAM
CHASE
A116
UTILITY
SOILED
C0-6
CORRIDOR
A142
STORAGE
CLEAN
A143
EXAM
A144
EXAM
A145
EXAM
C0-8
CORR
A112
EXAM
A113
EXAM
A114
EXAM
A115
EXAM
C0-7
CORRIDOR
A141
STORAGE
EQUIP.
A140
EXAM A139
EXAM
A138
EXAM
A
A
LC
O V
E D
IC
TA
TI
O
N
A136
EXAMAS1
STAIR
A135
INTAKE
A134
CHECK-OUT
A
S
TA
FF
P
A S
S A
G E A132
STORAGE
A131
MEN'S
C0-1
CORRIDOR
E-1
ELEV
A129
WAITING
A130
CHASE
REGISTRATION
WAITING
INTAKE
INTAKE
STAFF
STAFF
TOILET
M.O.D.
111A
SUPPLY
EQUIPMENT
111C
MULTI
PURPOSE
111D
TOILET
111B
UNISEX
TOILET
101A
HAC
NURSE
STATION
MED
LOCKERS
SOILED
UTILITIES
TELEMETRY
108A
TELEMETRY
108B
TOILET
108C
TELEMETRY
108D
TELEMETRY
108E
TELEMETRY
109C
TELEMETRY
109B
TELEMETRY
109A
TOILET
109D
AMBULANCE
CORRIDOR
C1EC
CORRIDOR
C1EA
NOUR
CORRIDOR
C1ED
HOLDING/
CAMERAS
111E
HOLDING/
CAMERAS
111F
TOILET
CORRIDOR
C1EB
A117
ROOM
MED
DECONTAM
01-E301
01-E301
CU-1-1
B01IT-1-11
WP
B01IT-1-CR-9,11
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:0
P
M
01-E201
FIRST FLOOR - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
FIRST FLOOR - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
N
0 8' 16'4'
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
INSIDE dgsf = 26,040 S.F.
STAIR A
RAMP
UP
A -O
-V
DN
UP
DN
UP
EXIST RM
A216
TELECOM ROOM
A200
ALIGN
01-E301
01-E301
1ES2-3
1EC2-2
1EB2-1
1L2-2
1L2-1
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:1
P
M
01-E202
SECOND FLOOR - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
SECOND FLOOR - ELECTRICAL
N
0 8' 16'4'
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
E E E
S
LO
P E D O W N
1/ 4" 1' -0
B01IT-3-11
WP
CU-1-4
CU-1-6
CU-1-7
CU-1-3
B01IT-2-CR-15
WP
B01IT-2-CR-9,11
B01IT-3-CR-19,21
B01IT-3-CR-9,11
B01IT-3-CR-13,15
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:1
P
M
01-E204
ROOF - ELECTRICAL
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/8" = 1'-0"
ROOF - ELECTRICAL
KEYNOTES:
1. PROVIDE ELECTRICAL CONNECTION TO
CONDENSING UNIT, AS REQUIRED.
COORDINATE FINAL LOCATION AND
CONNECTION REQUIREMENTS WITH
MECHANICAL.
N
0 8' 16'4'
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
GB
E E
E
FS
MS
C0-B1
CORR
A06
ELECTRICAL
A05A
MECHANICAL
A1
A
E
52. 1183
52. 1183
36. 00004B
TOILET
5E
OFFICE
PHYSICIAN
5C
CORR
5D
MECH
5B
MECH
HALL
C2-A2
ELECT.
A216
RECOVERY
A214
RECOVERY
ISOLATION
A215
SCHEDULING
CONSULT
E
EXISTING RADIOLOGY
DISTRIBUTION PANEL
TELECOM ROOM
A05C
EXISTING SWITCHBOARD MSB-1A
LS-1ATS-LS1EC1ATS-EQ1
EQ1
ATS-EQ1
LB1
EXISTING UPS
GLYCHOL PUMP BOX
SWITCHBOARD MCC-1
A200
TELECOM
ROOM9
1-L2-3
1EC2-5A
1EC2-5B
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:1
P
M
01-E300
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/4" = 1'-0"
BASEMENT DEMOLITION
ENLARGED - A05C - ELECTRICAL
1 1/4" = 1'-0"
BASEMENT DEMOLITION ENLARGED - 005F - ELECTRICAL
KEYNOTES:
1. RELOCATE CIRCUITING IN WALL TO AVOID NEW
DOOR OPENING.
2. EXISTING PUMPS AND CONTROLS SHALL BE
RELOCATED AS SHOWN ON POWER & SIGNAL
DETAIL. EXTEND CIRCUITING TO NEW
LOCATION.
3. DISCONNECT AND REMOVE LIGHTS AND
RECEPTACLES IN AREA OF NEW IT ROOM.
MAINTAIN CIRCUIT CONTINUITY TO ADJOINING
SPACES.
4. EXISTING LIGHT FIXTURE SHALL BE
DISCONNECTED REMOVED AND REINSTALLED
IN NEW CEILING GRID. RECONNECT TO
EXISTING CIRCUITING AS SHOWN ON SHEET
E301.
5. RELOCATE POWER FOR
EQUIPMENT/CONTROLS OUTSIDE NEW TR
ROOM.
6. RELOCATE EXISTING LIGHT TO AVOID NEW TR
ROOM WALL. MAINTAIN CIRCUIT CONTINUITY.
7. RELOCATE PULLBOX AND BRANCH
CIRCUITING.
8. MAINTAIN CIRCUIT CONTINUITY TO LIGHTING IN
ROOM.
9. EXISTING CONDENSING UNIT SHALL BE
RELOCATED AS SHOWN ON SHEET E301.
0 4' 8'2' 0 4' 8'2'
NN
100% CD 03/30
1/4" = 1'-0"
SECOND FLOOR DEMOLITION ROOF PLAN- A200 - ELECTRICAL
0 4' 8'2'
N
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
C0-B1
CORR
A06
ELECTRICAL
A05A
MECHANICAL
52. 1183
52. 1183
4B
5C
CORR
5B
MECH
5D
ROOM
MECH
GB
SD
E
FS
MS
E
E
C0-B1
CORR
A06
ELECTRICAL
A05A
MECHANICAL
SD
E
A1
A1
A
E
52. 1183
52. 1183
4B
5C
CORR
5B
MECH
5D
ROOM
MECH
SD
E
EE
NURSING A102A
A101
COMM
TELE-
SD
E
E
E E
E
A216
ELECT.
NURSING A102A
A101
COMM
TELE-
A05C
TELECOM
ROOM
A
B01IT-1
b
A
B01IT-1
b
A
B01IT-1-CR
a
A
B01IT-1-CR
a a b
005F
TELECOM
ROOM
005E
LOCKER
A
B01IT-2-CR
a
A
B01IT-2
b b a
A
B01IT-2-CR
a
A
B01IT-2
b
A05C
TELECOM
ROOM
B01IT-1-CR
AC-1-1
B01IT-1-7
42"
B01IT-1-CR-1
42"
B01IT-1-CR-1
42"
B01IT-1-7
42"
B01IT-1-CR-1
42"
B01IT-1-7
42"
B01IT-1-CR-1
42"
B01IT-1-1,3,5
B01IT-1-CR-3,5,7
B01IT-1
B01-ATS-2-EC2
1 SWITCHBOARD MCC-1
EC1 LS-1
005F
TELECOM
ROOM
005E
LOCKER
B01IT-2-CR
AC-1-3
B01IT-2-CR-1
42"
B01IT-2-CR-1
42"
B01IT-2-7
42"
B01IT-2-CR-1
42"
B01IT-2-7
42"
B01IT-2-CR-1
42"
B01IT-2-7
42"
B01IT-2-CR-3,5,7
B01IT-2-1,3,5
B01IT-2
AC-1-4
L-11 (60A/3P)
1EQ-1
(60A/3P)
1EQ-1
(60A/3P)
EXIST RM
A216
TELECOM ROOM
A200
ALIGN
B01IT-3-CR
AC-1-6
AC-1-7
B01IT-3-CR-1
42"
B01IT-3-7
42"
B01IT-3-CR-1
42"
B01IT-3-7
42"
B01IT-3-CR-1
42"
B01IT-3-7
42"
B01IT-3-CR-1
42"
B01IT-3-CR-3,5,7
B01IT-3-1,3,5
B01IT-3
1EC2-5A
1EC2-5B
1-L2-3
5 6
8 9
WP
WP
CU
A200
TELECOM
ROOM
A
B01IT-3
b
A
B01IT-3
b
A
B01IT-3-CR
a
A
B01IT-3-CR
a a b
A
1EQ-1
A
1EQ-1
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:3
P
M
01-E301
ELECTRICAL ENLARGED
PLANS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
1/4" = 1'-0"
BASEMENT ENLARGED - A05C - LIGHTING
1 1/4" = 1'-0"
BASEMENT ENLARGED - 005F - LIGHTING
1/4" = 1'-0"
BASEMENT ENLARGED - A05C - POWER & SYSTEM
4 1/4" = 1'-0"
BASEMENT ENLARGED - A05F - POWER & SYSTEM
5 1/4" = 1'-0"
FIRST FLOOR ENLARGED - A101 -
POWER & SYSTEM
81/4" = 1'-0"
SECOND FLOOR ENLARGED - A200
- POWER & SYSTEM
1/4" = 1'-0"
SECOND FLOOR ENLARGED - A200
- LIGHTING
KEYNOTES:
1. INDOOR UNIT TO BE POWERED BY OUTDOOR
UNIT. COORDINATE EXACT LOCATION WITH
M.C.
2. CONNECT SMOKE DETECTOR TO NEAREST
EXISTING SLC.
3. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-20R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#12, 1#12 GND
TO PANEL FOR EACH RECEPTACLE.
4. COORDINATE FINAL LOCATION OF
RECEPTACLE L21-30R WITH TELECOM
CONTRACTOR. PROVIDE 3/4"C-4#10, 1#10 GND
TO PANEL FOR EACH RECEPTACLE.
5. PROVIDE EATON BLADEUPS, 5KW, 120/208V, 3-
PHASE,4-WIRE RACK MOUNTED UPS FOR EACH
RACK TOWER.
6. PROVIDE APC#AP8861 RPDU RACK PDU 2G
WITH L21-20P CORD. (120/208V, 3-PHASE, 20A,
ZERO U, 5.7 KW, 208V, (36) C13 (6) C19 (2) 5-20R
OUTLETS. PROVIDE TWO PER RACK, MOUNTED
PER MANUFACTURER'S REQUIREMENTS.
7. PROVIDE ONE RACK MOUNTED ZONE PDU
UNIT. 30 AMP 3 PHASE, 120/208V, 5-WIRE WITH
(4) L21-30R, (6) 5-20R AND TWO 10' POWER
CORDS. ZONIT#ZPDS-208V-30A-L21-4L21-20R-
CR.
8. PROVIDE TWO J-BOXES IN CEILING OVER THE
CENTER RACK, IN LIEU OF RECEPTACLES .
PROVIDE 1”C – 4#8, & 1#8 GND BACK TO A
60A/3P BREAKER IN THE PANEL FOR EACH J-
BOX.
9. PROVIDE ONE RACK MOUNTED ZONE PDU
UNIT. 60 AMP, 3 PHASE, 120/208V, 5 WIRE WITH
(6) L21-20R AND TWO 10’ POWER CORDS. ZONIT
ZPDS-208V60A-HW-6L21-20R.
10. PROVIDE CONNECTION TO EXISTING CIRCUIT.
11. RELOCATED CHILLED WATER PUMPS AND
CONTROLLERS. EXTENT EXISTING CIRCUITING
(3#10 & 1#10GND) TO NEW LOCATION.
12. RELOCATED CONDENSING UNIT, EXTEND
EXISTING CIRCUITING TO NEW LOCATION.
13. EXTEND EXISTING RECEPTACLE FROM
EXISTING EXTERIOR RECEPTACLE BEING
REMOVED.
#SHEET NOTES:
1. REFER TO TECHNOLOGY PLANS FOR IT ROOM
LAYOUT AND RACK LAYOUT/DETAILS.
2. REFER TO SHEET 0-GE400 DETAIL LAYOUT &
ONE-LINE OF RACK.
0 4' 8'2'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
0 4' 8'2' 0 4' 8'2' 0 4' 8'2'
N NNN
N N N
100% CD 03/30
1/4" = 1'-0"
FIRST FLOOR ENLARGED - A101 -
LIGHTING
0 4' 8'2'
N
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
FIRST FLOOR
SECOND FLOOR
BASEMENT
B01IT-2-CR
B01IT-3-CR
100Y
B01IT-2B01IT-1 B01IT-1-CR
MSB-1A
100Y 100Y
B01IT-3
100Y
100Y
ISC 11.35 kA SCCR 22 kA
ISC 8.10 kA SCCR 10 kA
1 1 1 1 1
PNL 1-L2-3 PNL 1-MB PNL1-EC2-5A PNL 1-LB-5 (01) - EC1A
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:3
P
M
01-E400
ELECTRICAL ONE-LINE
DIAGRAMS
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
12" = 1'-0"
PARTIAL POWER RISER
KEYNOTES:
1. PROVIDE NEW 100A/3P CIRCUIT BREAKERS TO
MATCH EXISTING TYPE AND AIC RATING.
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:3
P
M
01-E500
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 60.4 A
TOTAL CONNECTED AMPS: 60.41 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 21.764 kVA
Power 21 kVA 100.00% 21 kVA TOTAL CONNECTED LOAD: 21.76 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 66.48 68.81 50.37
Total Load: 7.72 kVA 8.00 kVA 6.04 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 22 --
19 CU-1-4 15 A 2 12 -- 12 1 0 -- -- -- 1 20 A SPARE 20 --
17 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 18 --
-- 15 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 16 --
13 CU-1-7 15 A 2 12 -- 12 1 0 -- -- -- 1 20 A SPARE 14 --
-- 11 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 12 --
9 CU-1-6 15 A 2 12 -- 12 1 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 5 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 5 0 -- -- -- 1 20 A SPARE 6 --
3 RACK CONNECTION 60 A 3 4 -- 10 5 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 12 12 12 0.72 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: TELECOM ROOM A200 WIRE: 4
FED FROM: 150 A/3P @ 1EC2-5A GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-3-CR
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 32.7 A
TOTAL CONNECTED AMPS: 32.65 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 11.764 kVA
Power 11 kVA 100.00% 11 kVA TOTAL CONNECTED LOAD: 11.76 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 31.37 33.64 33.64
Total Load: 3.76 kVA 4.00 kVA 4.00 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
13 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 14 --
-- 11 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 12 --
9 CU-1-1 15 A 2 12 -- 12 1 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --
3 L21-30R RACK 30 A 3 10 10 10 3 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 12 12 12 0.72 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 150 A/3P @ SWBD CR GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-1-CR
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 33.2 A
TOTAL CONNECTED AMPS: 33.15 A
Receptacles 0.9 kVA 100.00% 0.9 kVA TOTAL ESTIMATED DEMAND LOAD: 11.944 kVA
Power 11 kVA 100.00% 11 kVA TOTAL CONNECTED LOAD: 11.94 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 31.37 35.14 33.64
Total Load: 3.76 kVA 4.18 kVA 4.00 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
15 WP GFI REC. 20 A 1 12 12 12 0.18 0 -- -- -- 1 20 A SPARE 16 --
13 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 14 --
-- 11 -- -- -- -- -- -- 1 0 -- -- -- 1 20 A SPARE 12 --
9 CU-1-3 15 A 2 10 -- 10 1 0 -- -- -- 1 20 A SPARE 10 --
-- 7 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --
3 L21-30R RACK 30 A 3 10 10 10 3 0 -- -- -- 1 20 A SPARE 4 --
1 TELECOM ROOM REC. 20 A 1 12 12 12 0.72 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES: PROVIDE INTEGRAL ELECTRIC METER IN PANEL.
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 150 A/3P @ 1-LB5 GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-2-CR
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d E
H R
M I n fr a s tr u ct u re
U p g ra d e s /6
-2
.B
.E
R
.r v t
/1
/2
:3
:3
P
M
01-E501
ELECTRICAL SCHEDULES
EHRM INFRASTRUCTURE
UPGRADES
656-21-235
TBD GJL
16305
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 27.1 A
TOTAL CONNECTED AMPS: 27.10 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 9.764 kVA
Power 9 kVA 100.00% 9 kVA TOTAL CONNECTED LOAD: 9.76 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 29.67 25.37 26.67
Total Load: 3.54 kVA 3.04 kVA 3.18 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 12 12 12 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 12 12 12 0.54 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 4 --
1 L21-30R RACK 30 A 3 10 10 10 3 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 150 A/3P @ MSB-1A GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-1
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 26.6 A
TOTAL CONNECTED AMPS: 26.60 A
Receptacles 0.54 kVA 100.00% 0.54 kVA TOTAL ESTIMATED DEMAND LOAD: 9.584 kVA
Power 9 kVA 100.00% 9 kVA TOTAL CONNECTED LOAD: 9.58 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 29.56 25.43 25.00
Total Load: 3.54 kVA 3.04 kVA 3.00 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
-- 11 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 12 12 12 0.54 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 3 0 -- -- -- 1 20 A SPARE 4 --
1 L21-30R RACK 30 A 3 10 10 10 3 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: WIRE: 4
FED FROM: 150 A/3P @ MB GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-2
CIRCUIT KEY NOTES:
*TOTAL DEMAND CALCS SUBTRACT ANY REDUNDANT LOAD AND THE SMALLER OF ANY NONCOINCIDENT HVAC LOADS. THIS CALC IS DONE AT EACH PANEL.
TOTAL ESTIMATED DEMAND AMPS: 43.8 A
TOTAL CONNECTED AMPS: 43.76 A
Receptacles 0.72 kVA 100.00% 0.72 kVA TOTAL ESTIMATED DEMAND LOAD: 15.764 kVA
Power 15 kVA 100.00% 15 kVA TOTAL CONNECTED LOAD: 15.76 kVA
Lighting 0.044 kVA 100.00% 0.044 kVA
LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND
TOTALS*
LOAD SUMMARY
Total Amps: 46.34 42.04 43.34
Total Load: 5.54 kVA 5.04 kVA 5.18 kVA
-- 29 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 30 --
-- 27 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 28 --
-- 25 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 26 --
-- 23 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 24 --
-- 21 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 22 --
-- 19 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 20 --
-- 17 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 18 --
-- 15 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 16 --
-- 13 SPARE 20 A 1 -- -- -- 0 0 -- -- -- 1 20 A SPARE 14 --
11 WP GFI REC. 20 A 1 12 12 12 0.18 0 -- -- -- 1 20 A SPARE 12 --
9 LIGHTING 20 A 1 12 12 12 0.04 0 -- -- -- 1 20 A SPARE 10 --
7 TELECOM ROOM REC. 20 A 1 12 12 12 0.54 0 -- -- -- 1 20 A SPARE 8 --
-- 5 -- -- -- -- -- -- 5 0 -- -- -- 1 20 A SPARE 6 --
-- 3 -- -- -- -- -- -- 5 0 -- -- -- 1 20 A SPARE 4 --
1 RACK CONNECTION 60 A 3 4 -- 10 5 0 -- -- -- 1 20 A SPARE 2 --
K E Y
CKT
NO. LOAD DESCRIPTION
OCPD
AMPS P
WIRE
SIZE
H N G
A B C
WIRE
SIZE
G N H
OCPD
P AMPS LOAD DESCRIPTION
CKT
NO.
K E Y
NOTES:
SCCR: 10 kA
LOCATION: TELECOM ROOM A200 WIRE: 4
FED FROM: 150 A/3P @ 1-L2-3 GROUND BUS PHASE: 3
ENCLOSURE: NEMA PB 1 SOLID NEUTRAL VOLTS: 120/208 Wye
MOUNTING: SURFACE MAIN: 100 A MCB
PANEL B01IT-3
100% CD 03/30
STAMP
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN# reby certify that this plan, specification ort was prepared by me or under my dir ervision and that I am a duly Licensed ineer under the laws of the State of Min me:
e: 03/30/202205-06-2022
ALEXANDER S. QUAST
06/14/2024 53095
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.No DATEREVISION
100% CD 03/30
RECORD DOCUMENTS 06/14
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
eby certify that this plan, specification rt was prepared by me or under my dir ervision and that I am a duly Licensed neer under the laws of the State of Min me:
A06
ELECTRICAL
5E
OFFICE
PHYSICIAN
5C
CORR
5D
MECH
5B
MECH
H W
S -E
H W
R -E
H W
R C
-E
S N
O W
M E
L T
S N
O W
M E
L T
AIR DRYER (E)
AIR COMPRESSOR
(E)
HWR-E
HWS-E
HWR-E
HWS-E
"C
W -E
SNOW MELT MANIFOLD (E)
6"FP-E
"F
P -E
4"FP-E
C O
N D
-E
3/4"COND-E
C W
-E
3/4"CW-E
4"GCHWR-E
POT FEEDER (E)
/4
-1
/4
-1
/4
"G
C H
W R
-E
AS (E)
ET (E)
FP RISER-E
C O
N D
-E
C W
-E
4"GCHWS-E
4"CW-E
"G
C H
W S
-E
HWS-E UP
HWR-E UP
2 3 x
KEYPLAN - BASEMENT
NOT TO SCALE
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
I hereby certify that this plan, specification or report was prepared by me or under my direct supervision and that I am a duly Licensed Engineer under the laws of the State of Minnesota.
Name:
Date: 03/30/2022
License Number: MN#
03/30/2022
B
IM
/2
.0
V A
S t C lo u d
E H
R M
I n fr a s tr u c tu re U p g ra d e s /6
-2
.B
.M
R
.r v t
/1
/2
:4
:1
A
M
01-M100
BASEMENT DEMOLITION -
MECHANICAL
EHRM INFRASTRUCTURE
UPGRADES
656‐21‐235
RDL JCL
16305
1/4" = 1'-0"
BASEMENT DEMOLITION -MECHANICAL - TELECOM A05C
1 1/4" = 1'-0"
BASEMENT DEMOLITION - MECHANICAL - TELECOM 005F
KEYED NOTES 1/01-M100:
1. CAREFULLY REMOVE EXISTING SNOW MELT MANIFOLD AND STORE FOR RE-
INSTALLATION AS SHOWN ON 01/01-M200.
2. EXISTING 4" GLYCOL CHILLED WATER
3. EXISTING 4" FIRE SPRINKLER MAIN PIPING TO BE REROUTED.
4. EXISTING AIR SEPARATOR TO BE RELOCATED.
5. EXISTING SNOW MELT PIPING TO BE REROUTED.
6. EXISTING 1" CONDENSATE DRAIN TO BE REROUTED.
7. EXISTING EXPANSION TANK TO BE RELOCATED.
8. EXISTING CHILLED WATER PUMPS TO BE RELOCATED.
9. EXISTING PRESSURE SWITCHES TO BE RELOCATED.
10. EXISTING CHEMICAL POT FEEDER TO BE RELOCATED.
11. EXISTING 1" DOM WATER
12. EXISTING 1" COND DRAIN
13. EXISTING FIRE SPRINKLER
14. EXISTING 1" EXPANSION LINE
15. EXISTING 4" DOM WATER
16. EXISTING 2-1/2" FIRE SPRINKLER LINE UP.
17. EXISTING HWS & HWR BRANCH LINES.
18. DISCONNECT COMPRESSED AIR PIPING. CAREFULLY REMOVE COMPRESSOR
AND AIR DRYER, AND STORE FOR REINSTALLATION IN LOCATION SHOWN ON
1/01-M200.
19. REFER TO SHEET PHOTOS FOR EXISTING CONDITIONS - FIELD COORDINATE
DEMOLITION WORK AS REQUIRED.
KEYED NOTES 2/01-M100:
1. DEMOLISH EXISTING FIN-TUBE RADIATION AND CABINET. DEMOLISH PIPING BACK
TO MECHANICAL ROOM AND CAP IN PREPARATION FOR CONNECTION OF NEW
CABINET UNIT HEATER.
2. REMOVE SUPPLY AIR DIFFUSER AND BRANCH DUCT AS SHOWN.
3. EXISTING SUPPLY DUCT MAIN TO REMAIN.
4. EXISTING SPRINKLERS AND BRANCH PIPING IN THIS AREA TO REMAIN.
5. EXISTING FIRE PROTECTION SPRINKLER HEADS AND PIPING TO BE
RECONFIGURED.
6. REFER TO SHEET 01-M200 FOR REMODEL WORK IN THIS AREA.
7. EXISTING AIR HANDLING UNIT TO REMAIN.
8. EXISTING DUCTWORK TO REMAIN.
9. REMOVE DUCTWORK SHOWN AND PREPARE FOR REROUTING.
FIELD VERIFICATION NOTES
1. THE HVAC CONTRACTOR SHOULD VISIT THE SITE PRIOR TO BID TO FIELD VERIFY ALL EXISTING CONDITIONS WHICH MAY AFFECT THEIR
BID. THE FOLLOWING ITEMS SHALL BE VERIFIED:
A. EXACT PLACEMENT, SIZE, CAPACITY, MANUFACTURER, AND CONDITION OF ALL EXISTING HVAC EQUIPMENT WITHIN SCOPE OF
WORK, WHETHER EXPLICITY SHOWN OR NOT.
B. SIZE AND LOCATION OF ALL EXISTING DUCTWORK.
C. SIZE AND LOCATION OF ALL EXISTING GRILLES, REGISTERS AND DIFFUSERS.
D. SIZE AND LOCATION OF ALL EXISTING THERMOSTATIC CONTROL DEVICES.
E. SIZE AND LOCATION OF ALL EXISTING PLUMBING AND HYRONIC PIPING.
2. ALL REFERENCES ON THESE DRAWINGS TO EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, THERMOSTATS AND PIPING ARE FOR REFERENCE ONLY. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY ALL THESE ITEMS PRIOR TO BID AND INCLUDE IN THEIR
BID ANY AND ALL AMOUNTS REQUIRED TO ACCOMMODATE EXISTING CONDITIONS.
3. NO ADDITIONAL COMPENSATION WILL BE MADE AFTER THE PROJECT HAS BEEN AWARDED FOR FAILURE TO VERIFY EXISTING
CONDITIONS.
4. ANY DISCREPANCIES WHICH MAY AFFECT THE CONTRACTORS BID SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
ARCHITECT FOR DIRECTION.
0 4' 8'2' 0 4' 8'2'
NN
100% CD 03/30
5 Revision 5 12/09
/22
1/8" = 1'-0"
A05C PHOTOS
SNOW MELT MANIFOLD CHEMICAL FEED PIPING GLYCOL CHILLED WATER PIPING
(LOOKING SOUTH)
06/14/2024
RECORD DOCUMENTS 06/14
Robert D. Lowe
24706
RECORD
DRAWINGS
THIS IS A RECORD DRAWING BASED ON INFORMATION RECEIVED FROM THE
CONTRACTOR AND IS TO BE USED FOR THE SOLE PURPOSE OF MAINTENANCE OF
THE ORIGINAL FACILITY FOR WHICH THIS DRAWING WAS PREPARED AND NOT
FOR ADDITIONAL CONSTRUCTION.
No DATEREVISION
RECORD DOCUMENTS 06/21/24 06/21/2024
-RECORD DOCUMENT-
June 21, 2024 This Record Document has been prepared based on
Designer of Record drawings with Contractor provided markups through the construction phase of the project at the direction of the VA.
While the construction information is believed to be reliable, Architect/Engineer cannot assure its accuracy, and is not responsible for the accuracy of this Record Document. Those relying on this Record
Document are advised to independently verify its accuracy before applying it for any purpose.
T
EXAM
EXAM
A101
COMM
TELE-
A102A
WOMEN'S
A103
CONSULT
SHARED
A102B
CHASE
FS
1 2
3 4
EXISTING
REGISTER
KEYPLAN - FIRST FLOOR
NOT TO SCALE
No DATEREVISION
DRAWING TITLE
CHECKED BY
ST.CLOUD, MN 56303
VA MEDICAL CENTER
BUILDING No
LOCATION
DRAWING NO.DRAWN
DWG. OF
PROJECT TITLE
PLOT SCALE
PROJECT NO.
DATE:
CONSULTANT ARCHITECT/ENGINEER OF RECORD STAMP
FULLY
SPRINKLERED
A
B
C
D
E
F
A
B
C
D
E
F
21…
This is the start of the file's text. The full file is on GovTribe.