Attachment 6 - GT_STABLE_REROOF_PLAN-GT A-5.pdf

PDF 198 KB Posted

Attached to
Grey Towers Roof Repairs
Solicitation number
12445525Q0008
Issued by

About this file

This document is a detailed architectural drawing sheet (A-5) for the Grey Towers Stables Reroof project, showing soffit and crown detail specifications for a roof restoration at a historic site. The technical drawing includes precise diagrams illustrating roofing components such as rafter rim board/sub-fascia, cedar fascia, crown moulding, starter course shingles, plywood sheathing, ice and watershield membrane, and existing cedar soffit. The drawings provide technical guidance for roof repair, emphasizing careful replacement and restoration of specific architectural elements, with notations to use a profile gauge for exact dimensions and to replace/repair any sections with holes or cracks. The document is part of a United States Department of Agriculture Forest Service project for the Grey Towers Historic Site, specifically focusing on the stables' roof renovation scheduled for 2024.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

RAFTER RIM BOARD/SUB-FASCIA

CEDAR FASCIA

CROWN MOULDING -USE PROFILE GAUGE FOR EXACT

DIMENSIONS AND SHAPE

STARTER COURSE, DOUBLE SHINGLES, 1.5" OVERHANG

EXISTING 38" CEDAR SOFFIT- REPLACE/REPAIR ANY SECTIONS

WITH HOLES OR CRACKS

16" PLYWOOD SHEATHING

FELT OVER ICE AND WATERSHIELD

2 X NAILER

ICE AND WATERSHIELD

EXISTING TRANSVERSE LATHING

CROWN AND SOFFIT DETAIL2 NOT TO SCALE

CEDAR BREATHER DETAILS1

PASTE

ICE AND WATERSHIELD

ON SHEATHING

ICE AND WATERSHIELD

ON SHEATHING

NOT TO SCALE

* SHOWN TO ILLUSTRATE COMPONENTS

FOR ANY REQUIRED REPAIRS *

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

8/5 /24

0:

M

IC

HA

EL

W

EW

ER

KA

C

:\U

SE

RS

\M

IC

HA

EL

W

EW

ER

KA

\B

OX

\M

W W

OR

K

SP

AC

E\

GR

EY

T

OW

ER

S\

GT

_S

TA

BL

E_

RE

RO

OF

_P

LA

N.

DW

G;

R9

EASTERN REGION

GREY TOTWERS

STABLES

REROOF

GREY TOWERS HISTORIC

SITE

GREY TOWERS

SOFFIT AND CROWN

DETAIL

8/3/2024

MEW

MEW

SMHW

24-ENG-WGTH-85

A-5

5 5SOFFIT AND CROWN DETAIL

PASTE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

Sheets and Views
GT A-5

File details come from the government source that posted it. Updated .