Attachment 5 - GT_STABLE_REROOF_PLAN-GT A-4.pdf

PDF 219 KB Posted

Attached to
Grey Towers Roof Repairs
Solicitation number
12445525Q0008
Issued by

About this file

This is a technical roofing design drawing (Sheet A-4) for the Grey Towers Stables Reroof project, prepared by the United States Department of Agriculture Forest Service's Eastern Region. The detailed architectural drawing provides comprehensive roof section and valley details, specifically illustrating the roofing construction methodology for a historic site.

The drawing includes precise technical specifications for roof components, featuring cedar shingle roofing, multiple felt layers, 7/16" plywood sheathing, ice and water shield, metal flashing, and galvanized W-shape valley installation. Key structural elements are annotated, such as existing ridge board, 2x6 collar ties, 2x8 rafters spaced at 24" on center, and horizontal purlins. The technical drawing provides multiple detailed views including a ridge detail with existing framing members, a slope transition detail, and a valley flashing diagram, all drawn to demonstrate precise roofing installation techniques for the historic Grey Towers site.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CEDAR SHINGLE RIDGE

RIDGE BREATHER

CEDAR SHINGLES

FELT LAYER

16" PLYWOOD SHEATHING

NEW SHEATHING-7/16" PLYWD

METAL FLASHING 8" UP, 8" BELOW

ICE AND WATER SHIELD

FELT LAYER

FELT LAYER

ICE AND WATER SHIELD

FELT LAYER

20" X 10' GALVANIZED W SHAPE VALLEY,

OPEN VALLEY WIDTH 8"

OVERLAP JOINTS MIN 6"

METAL EXTENDS AS FAR AS SHINGLES

16" PLYWOOD SHEATHING

VALLEY FLASHING DIAGRAM3 (SHINGLES NOT SHOWN)

RIDGE DETAIL WITH EXISTING FRAMING MEMBERS2 NOT TO SCALE

SLOPE TRANSITION DETAIL1 (SHINGLES NOT SHOWN)

RAFTER SPACING

RAFTER SPACINGVALLEY TYPE

FLAT DIAG

ARIAL

FLAT DIAG

PASTE

PASTE

EXISTING RIDGE BOARD TYP OF 2

EXISTING 2 X 6 COLLAR TIE @ 48"OC, TYP.

EXISTING 2 X 8 RAFTER @24"OC, TYP.

EXISTING +/- 54 "X 2" HORIZONTAL PURLINS, @ +/- 6" OC

CEDAR BREATHER

FELT

ROLL FELT OVER SHINGLE 2", CAULK EDGE

HEMMED EDGES ON GLALVANIZED W-VALLEY

EXISTING HORIZONTAL PURLINS

NTS NTS

FELT LAYER

*PURLINS, RAFTERS, ETC

NOT SHOWN*

DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

8/5 /24

0:

M

IC

HA

EL

W

EW

ER

KA

C

:\U

SE

RS

\M

IC

HA

EL

W

EW

ER

KA

\B

OX

\M

W W

OR

K

SP

AC

E\

GR

EY

T

OW

ER

S\

GT

_S

TA

BL

E_

RE

RO

OF

_P

LA

N.

DW

G;

R9

EASTERN REGION

GREY TOWERS

STABLES

REROOF

GREY TOWERS HISTORIC

SITE

GREY TOWERS

ROOF SECTION,

VALLEY DETAILS

8/3/2024

MEW

MEW

SMHW

ENG-24-WGTH-85

A-4 4 5

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

Sheets and Views
GT A-4

File details come from the government source that posted it. Updated .