This document is a roof plans drawing for the Grey Towers Stables Reroof project for the USDA Forest Service Eastern Region. The technical specifications detail a comprehensive roof replacement process involving multiple critical steps: (1) removing existing wood shingles down to transverse lathing, (2) installing 7/16" plywood sheathing, (3) applying ice and water shield underlayment, (4) covering the entire roof with ASTM-specified felt, and (5) installing new cedar shingles with 5" exposure. The roof has multiple slope configurations (12:12 and 6:12 slopes) and requires precise historic preservation techniques, including matching existing historic components exactly and obtaining Contracting Officer's Representative (COR) approval for any deviations. Additional requirements include installing cedar breather, w-valley and slope transition flashing, and carefully protecting and potentially repairing existing historic fascia, soffit, and trim elements.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NOTES:

1. CONTRACTOR TO REMOVE EXISTING WOOD

SHINGLES DOWN TO THE TRANSVERSE LATHING.

2. SET REMAINING NAILS ON TRANSVERSE LATHING.

3. SHEATH ENTIRE ROOF WITH 7

16 PLYWOOD

4. NAIL SHEATHING TO TRANSVERSE LATHING.

5. FOR ALL EXPOSED WOOD COMPONENTS,

CONTRACTOR SHALL MATCH EXISTING HISTORIC

COMPONENTS EXACTLY. OBTAIN PRIOR APPROVAL

FROM COR FOR ANY PROPOSED DEVIATION.

6. PROTECT ALL EXISTING HISTORIC FASCIA BOARD,

SOFFIT AND TRIM DURING ALL OPERATIONS.

7. REPAIR, RESTAIN AND REPLACE SECTIONS OF

SOFFIT, FASCIA AND TRIM AS REQUIRED. USE

PROFILE GAUGE TO GET EXACT PROFILE OF

CROWN MOLDING. GET APPROVAL FROM COR ON

PROFILE SHAPES AND QUANTITY TO BE REPLACED.

8. CONTRACTOR SHALL MEASURE AND VERIFY ALL

EXISTING HISTORIC COMPONENTS OF FASCIA AND

TRIM, AND BRING ANY INCONSISTENCIES TO THE

ATTENTION OF THE COR BEFORE PROCEEDING

WITH ANY REMEDIATION.

9. APPLY ICE AND WATER SHEILD UNDERLAYMENT PER

UNDERLAYMENT PLAN.

10. COVER ENTIRE ROOF WITH No. 30 ASTM D226 Type II OR No. 30 ASTM D4869 Type IV FELT, PER MFGS

INSTRUCTIONS

11. INSTALL W-VALLEY AND SLOPE TRANSITION

FLASHING PER THESE DRAWINGS AND SPECS.

12. INSTALL CEDAR BREATHER OVER ENTIRE ROOF.

13. INSTALL NEW CEDAR SHINGLES WITH 5" EXPOSURE.

14. INSTALL CEDAR RIDGE AND BREATHER PER THESE

DRAWINGS AND SPECS.

UNDERLAYMENT PLAN

= AREAS TO BE COVERED WITH ICE AND WATERSHIELD,

UNDER CONTINUOUS FELT LAYER

* ENTIRE ROOF TO BE COVERED WITH

ASTM D226 TYPE II OR ASTM D4869 TYPE IV FELT,

AFTER APPLICATION OF ICE AND WATERSHIELD.

UNDERLAYMENT PLAN

DIAGRAM, NTS DRAWN

DESIGNER

STAMPS, LOGOS, AND SEALS

PROJECT NAME

DRAWING TITLE

CHECKED

ARCHIVE NO.DATE

PROJECT NO.

DRAWING SHEET NO.

DATENO.

REVISION / ISSUE

OFSHEET

United States Department of Agriculture Forest Service

8/5 /24

0:

M

IC

HA

EL

W

EW

ER

KA

C

:\U

SE

RS

\M

IC

HA

EL

W

EW

ER

KA

\B

OX

\M

W W

OR

K

SP

AC

E\

GR

EY

T

OW

ER

S\

GT

_S

TA

BL

E_

RE

RO

OF

_P

LA

N.

DW

G;

R9

EASTERN REGION

GREY TOWERS

STABLES

REROOF

GREY TOWERS HISTORIC

SITE

GREY TOWERS

ROOF PLANS

8/3/24

MEW

MEW

SMHW

24-ENG-WGTH-85

A-3 3 5

DIAGRAM OF ROOF PLANES

12:12 SLOPE

12:12 SLOPE

6:12 SLOPE

6:

S

LO

PE

:1

SL

O

PE

:1

SL

O

PE

DIAGRAM SHOWING APPROXIMATE

SLOPES AND DIMENSIONS OF

ROOF PLANES, VALLEYS AND SLOPE

TRANSITIONS. CONTRACTOR TO

FIELD VERIFY ALL DIMENSIONS.

NTS

SMALL SECTION

UNDER GABLE END

REPLICATE EXISTING FLASHING DETAILS

AutoCAD SHX Text 7'-6"

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

AutoCAD SHX Text E

Sheets and Views
GT A-3

File details come from the government source that posted it. Updated .