This document contains the asbestos survey findings for the 1st and 2nd floors of the main building at the VA Medical Center in Wilkes-Barre, PA. The survey identified the presence of asbestos-containing materials (ACMs) in various building components such as floor tiles, floor tile mastics, pipe insulation, transite panels, and duct insulation. The report provides detailed information on the location, condition, quantity, and asbestos content of the identified ACMs. This information would be important for planning any renovation or demolition activities at the facility to ensure proper handling and disposal of the ACMs.
The related federal contract opportunity is for a project to expand the mental health clinic at the Wilkes-Barre VA Medical Center. The solicitation is a competitive Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside. The contractor will be required to provide all labor, project management, materials, tools, supplies, and equipment necessary to complete the work as detailed in the drawings and specifications. The project location is the Wilkes-Barre VA Medical Center at 1111 East End Blvd, Wilkes-Barre, PA 18711.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Building 1, Floor I - Specific Survey Findings Project No. VAMC: 10013.00-IN
VA Medical Center, Main Building, 1 st
Floor Adelaide Environmental Health Services, Inc. – Project No. VAMC:10013.00-IN
1511 Route 22, Suite C24, Brewster, NY 10509 Phone: 845.278.7710 Fax: 845.278.7750
Adelaide Environmental Health Associates, Inc.
Project: Main Building, 1 st
Floor Inspector(s): James Reber
VA Medical Center Thomas Ferro Wilkes-Barre, PA 18711 Date(s): 2/2010-3/2010
LOCATION MATERIAL QUANTITY CONDITION SAMPLE #
HOMOGENEOUS
WITH SAMPLE #
ASBESTOS CONTENT
st
Floor, W wing, room C1-01
Floor Rug over red brown 9” X9” floor tile 280 ft2 N/A 4/12-03 N/A 15% Chrysotile
Walls Sheetrock/plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 32-64ft2 Damaged Assumed
1st Floor, W wing, room C1-02 (suite)
Floor Rug over floor tile 360 ft2 N/A 4/12-01 N/A 3% Chrysotile Mastic 360 ft2 N/A 4/12-02 N/A 10% Chrysotile
Walls Sheetrock/plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles N/A N/A N/A V Non-suspect
Plaster N/A N/A N/A N/A Non-suspect
1st Floor, room C1-03
Floor Rug over floor tile N/A N/A N/A N/A Non-suspect
12” X 12” floor tile 160 ft2 N/A N/A Prev. tested pos. >1%
Floor tile mastic 160 ft2 N/A N/A Prev. tested pos. >1%
SOL# 36C77624R0079 Project # 693-352 Expand Mental Health Clinic Construction- Wilkes-Barre, PA
VA Medical Center, Main Building, 1 st Floor
Adelaide Environmental Health Services, Inc. – Project No. VAMC:10013.00-IN
Adelaide
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
12” X 12” ceiling tiles (above 2’ X 4’)
160 ft2 N/A N/A 1-195 None detected
Univents Transite panels 20-40 ft2 Damaged N/A N/A Assumed
1st Floor, room C-1-03A
Floor Rug over tile N/A N/A N/A N/A Non-suspect
12” x 12” floor tile and mastic 200 ft2 N/A N/A Previously tested positive >1%
12” X 12” ceiling tiles (off white w/ grainy surface) – above 2’ X 4’
N/A N/A 1-195 N/A None detected
Univents Transite panels 20-40 ft2 Damaged N/A N/A Assumed
1st Floor, W wing, room C1-05 (suite) – 05 , 06, 07, 08, 09, 10, 11, 12, 13
Floor Rug over concrete or platform N/A N/A N/A N/A Non-suspect
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X4’ ceiling tile N/A N/A N/A N/A Non-suspect
12” X 12” ceiling tiles ( white w/rows of holes) – above 2’ X 4’
N/A N/A N/A 1-187 None detected
Univents Transite panels (one front panel missing)
100-200 ft2 Damaged N/A N/A Assumed
Over ceiling, far S wall
Duct insulation (black mastic over cork)
Not found N/A N/A 6-96 Not found
Chases + over ceiling in room next to ladies room
Pipe insulation (C1-11) 12 LF Good N/A N/A Assumed
SOL# 36C77624R0079 Project # 693-352 Expand Mental Health Clinic Construction- Wilkes-Barre, PA
Floor
1st Floor, W wing, ladies’ (C1-14) and men’s (C1-15) rooms across from C1-05
In wall between mens/ladies rooms
Pipe insulation 5 LF Good N/A N/A Assumed
1st Floor, W wing, electrical closet (E of stair #1)
Pipe riser Pipe insulation (black mastic over cork)
10 LF Good N/A 6-96 8% Chrysotile
1st Floor, room C1-18
Floor 12” X 12” floor tile (light gray w/white dark gray mottles)
100 ft2 N/A N/A 6-105 None detected
Floor tile mastic 100 ft2 N/A N/A 6-106 5% Chrysotile
Ceilings 2’ X 2’ ceiling tiles N/A N/A N/A N/A Non-suspect
Univents Transite panels 24-48 ft2 Damaged N/A N/A Assumed
1st Floor, room C1-19
Floor Rug over leveling compound over black mastic Removed
N/A N/A N/A N/A N/A
Black mastic Removed 150 ft2 N/A N/A N/A N/A
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
1st Floor, rooms C1-21B and C1-21C and C1-20
Floor Rug over floor tile - Removed N/A N/A N/A N/A N/A
12” X 12” floor tile - Removed 150 ft2 N/A N/A N/A N/A
Walls Plaster/ sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles N/A N/A N/A N/A Non-suspect
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
Floor
1st Floor, W wing, room C1-21A - Removed and is part of C1-22A now
Floor 12” X 12” floor tile (white w/olive mottles) - Removed
525 ft2 N/A N/A N/A
Floor tile mastic - Removed 525ft2 N/A N/A N/A
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles N/A N/A N/A N/A Non-suspect
1st Floor, room C1-22A (and also C1-21B and C1-21C)
Floor (raised floor;
tiles not found underneath)
12” X 12” floor tile (off-white w/tan & brown streaks) - Removed
N/A N/A N/A 6-103 5% Chrysotile
Floor tile mastic - Removed N/A N/A N/A 6-104 5% Chrysotile
Walls Sheetrock N/A N/A N/A Previously tested positive >1%
Ceilings 2’ X 4’ ceiling tiles - removed N/A N/A N/A Previously tested positive >1%
1st Floor, room C1-22
Floor 12” X 12” floor tile (white w/brown streaks) –E room (C1-22D
150 ft2 N/A N/A 6-103 5% Chrysotile
Floor tile mastic 150 ft2 N/A N/A 6-104 5% Chrysotile
12” x 12” floor tile (off white w/tan marks) –W room
150 ft2 N/A N/A 3-165 None detected
Floor tile mastic- W room 150 ft2 N/A N/A 3-166 5% Chrysotile
Ceilings 2’ X 4’ ceiling tiles N/A N/A N/A N/A Non-suspect
C1-22E has pipe insulation – 8 LF, good. Same floor tiles as C1-22 – 484 ft2. Has suspect drywall on S wall - 30ft2, damaged
Floor
1st Floor, mechanical room behind C1-22 (on drawings as C1-22C)
12” X 12” floor tile (off-white w/tan marks)
400 ft2 N/A N/A 3-165 None-detected
Floor tile mastic 400 ft2 N/A N/A 3-166 5% Chrysotile
1st Floor, room C1-23
Floor Rug N/A N/A N/A N/A Non-suspect
12” X12’ floor tile 400 ft2 N/A N/A N/A Assumed
Floor tile mastic 400 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tiles & plaster
Pipe insulation 10 LF Damaged N/A N/A Assumed
1st Floor, room C1-24 and C1-27 (Armory)
Floor 12” X 12” floor tile (off white w/tan & dark tan mottles)
N/A N/A N/A Non-suspect
Floor tile mastic N/A N/A N/A Non-suspect
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles (worm markings) N/A N/A N/A N/A Non-suspect
Univents Transite panels ( front panels removed)
24-48 ft2 Damaged N/A N/A Assumed
Chases Pipe insulation N/A N/A N/A N/A Assumed
Floor
1st Floor, room C1-28
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
12” x !2” floor tile and mastic - Removed
200 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (off white w/random pock markings)
200 ft2 N/A N/A N/A Non-suspect
Univents Transite panels 24-48 ft2 Damaged N/A N/A Assumed
1st Floor, Room C1-32
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile- new V V V V Non-suspect
Chases Pipe insulation – no view in chases indeterminate N/A N/A N/A Assumed
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
1st Floor, rooms C1-32-A and C1-32B – No suspect materials observed
Floor
1st Floor, E wing, room C1-30
Floor 9” X 9” floor tile (brown) 25 ft2 Good N/A N/A Assumed
Floor tile mastic 25 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
1st Floor, E wing, room C1-35A
Pipes Pipe insulation (black mastic over cork)
12 LF N/A N/A 6-96 8% Chrysotile
1st Floor, rooms C1-36 and C1-37
Ceilings 12” X 12” ceiling tiles (white, perforated)
20-30 ft2 N/A 1-187 N/A None detected
2’ X 2’ ceiling tiles N/A N/A N/A N/A Non-suspect
Ceiling tile mastic 20-30 ft2 N/A 1-188 N/A None detected
Univents Transite panels 32-64 ft2 Damaged N/A N/A Assumed
1st Floor, E wing, room C1-36A
S wall Pipe insulation 30 LF Significant damage
N/A N/A Assumed
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
Comments: Behind the plaster fascia, there is a pipe chase which runs E to W on the S wall. Suspect pipe insulation may exist within the chase, and this situation may exist in all rooms within this area
1st Floor, room C1-38
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tiles- new and 12” X 12”
N/A N/A N/A N/A Non-suspect
Univents Transite panels 40 – 80 ft2 Damaged N/A N/A Assumed
Floor
1st Floor, E wing, rooms C1-43,C1-44, C1-45, C1-51, C1-52, 56A – No exposed suspect asbestos materials observed
1st Floor, E wing, rooms C1-39, C1-40, C1-41, & C1-42
Univents Transite panels 50 ft Damaged N/A N/A Assumed
Comments: Except for C1-42, the front transite panels have been removed. The rear could not be observed at the time of this inspection and could be present.
1st Floor, room C1-53
Pipe in SW corner Pipe insulation in chase- can’t see condition
N/A N/A N/A N/A Assumed
1st Floor, room C1-54
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tiles Pipe insulation (SE corner) 5 LF Good N/A N/A Assumed
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
1st Floor, room C1-56-B, C1-56C (Corridors)
Floors 12” X12” floor tile Terrazzo N/A N/A N/A N/A Non-suspect
Floor tile mastic N/A N/A N/A N/A N/A
Walls Plaster/ N/A N/A N/A N/A Non-suspect
Ceilings 2’ x 4’ ceiling tile over fireproofing N/A N/A N/A N/A Non-suspect
Floor
1st Floor, C1-56
12” X 12” floor tile (brown w/ white, gray and dark brown marble effect)
480 ft2 N/A N/A 1-01 None detected
Floor tile mastic 480 ft2 N/A N/A 1-02 3% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles (concrete deck) N/A N/A N/A N/A Non-suspect
Above ceiling Pipe insulation (runs down into SW wall)
15-20 LF
Significant damage
N/A N/A Assumed
Univents Transite panels 32-64 ft2 Damaged N/A N/A Assumed
1st Floor, room C1-55
Floor Rug over floor tile N/A N/A N/A N/A Non-suspect
12 X 12” floor tile 160 ft2 N/A N/A N/A Assumed
Floor tile mastic 160 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 12” X 12” ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
1st Floor, smoking area NOT FOUND – Non-existing
Floor 12” X 12” floor tile (off-white w/ tan & dark tan mottles)
625 ft2 N/A 8-281 N/A None detected
Floor tile mastic 625 ft2 N/A 8-282 N/A <1% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 12” X 12” ceiling tile N/A N/A 8-283 N/A None detected
Floor
1st Floor, room C1-59
12” X 12” floor tile (off-white w/gray mottles) and mastic
115 ft2 N/A N/A Previously tested positive >1%
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above & behind plaster
Pipe insulation 20-30 LF N/A N/A v N/A Assumed
1st Floor, ladies room (C1-60) & men’s room (C1-61) plus C1-58 (vestibule)
Above ceiling and in walls where it was partially removed and replaced w/ fiberglass
Pipe insulation N/A Damaged N/A N/A Assumed
Comment: C1-58 vestibule – 18 LF of pipe (aircell). Nothing above men’s room/no access to ladies room ceiling
1st Floor, room C1-62
Floor Ceramic Tile N/A N/A N/A N/A Non-suspect
Walls Tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, room C1-63
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Tile N/A N/A N/A N/A Non-suspect
Floor
1st Floor, C1-64
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (white w/ striations)
N/A N/A N/A N/A Non-suspect
1st Floor, room C1-65, C1-66, C1-67, C1-68
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A Previously tested Non-suspect
Comments: In rooms C1-63 through C1-68, suspect asbestos insulation possible on pipes above plaster ceiling
1st Floor, W wing, room C1-70
Floor Rug over 12” X 12” floor tiles/mastic
185 ft2 N/A N/A N/A Assume
Walls Plaster/sheetrock N/A N/A N/A` N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, room C1-71 and C1-70-A
Floor Rug over brown 9X9 floor tile and mastic
360 ft2 N/A N/A N/A Assumed
12” X 12” ceiling tile (white w/rows of holes) – above 2’ X 4’
160 ft2 N/A N/A 1-187 None detected
Floor
1st Floor, W wing, room C1-72
Rug over leveling compound and brown 9X9 floor tile and mastic
180 ft2 N/A N/A N/A Assumed
Walls Plaster N/A N/A N/A N/A Non-suspect
Sheetrock joint material N/A N/A 1-196 N/A None detected
Ceilings 2’ X 4’ ceiling tiles N/A N/A N/A N/A Non-suspect
12” X 12” ceiling tiles (off-white w/ holes) – above 2’ X 4’
150 ft2 N/A N/A 1-187 None detected
1st Floor, W wing, rooms C1-74a, C1-74, & C1-73
Floor Rug over brown 9X9 floor tile and mastic
450 ft2 Good N/A N/A Assumed
Ceilings 2’ X 4’ Ceiling tile N/A N/A N/A N/A Non-suspect
12” X 12” ceiling tiles (white w/rows of holes) – above 2’X4’
380 ft2 N/A N/A 1-187 None detected
Comments: No access under rug at the time of this inspection –possible floor tile and mastic materials under rug. Checked - Floor tile found
1st Floor, room C1-76
Pipes Pipe / fitting insulation 4-6 LF N/A N/A N/A Assumed
1st Floor, room C1-77
Floor 9” X 9” floor tile (white w/ black flecks)
110 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Floor
1st Floor, hall by main elevator
Floor Terrazzo tile N/A N/A N/A N/A Non-suspect
Walls Marble N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, main hall (mental health to Chapel Hall) (C1-18)
Floor 12” X 12” floor tile (tan w/ white/dark tan mottles)
2696 ft2 N/A N/A 8-039 None detected
Floor tile mastic 2696 ft2 N/A N/A 8-040 2% Chrysotile
1st Floor, security locker room by stair # 3 (C1-78)
Floor
12” X 12” floor tile (chocolate w/ white/brown marble effect)
40 ft2 N/A N/A 7-86 None detected
Floor tile mastic
40 ft2 N/A N/A 7-87 5% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings Ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 4 ft2 Damaged N/A N/A Assumed
1st Floor, N wing, N1-71 ( Not on plans or in field)
Floor Rug over leveling compound N/A N/A N/A N/A Non-suspect
Walls Plaster/carpeted panels N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile Pipe insulation 8 LF Damaged N/A N/A Assumed
Univents Transite Panels 16-32 ft2 Damaged N/A N/A Assumed
Floor
1st Floor, N wing, room N1-80
12” X 12” floor tile ( off-white w/ light & dark olive mottles)
216 ft2 N/A N/A 1-286 5% Chrysotile
Floor tile mastic 216 ft2 N/A N/A 1-287 3% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-81 ( room N of N1-80)
Floor Rug over floor tile N/A N/A N/A N/A Non-suspect
12” X 12” floor tile (off-white w. light & dark olive mottles)
300 ft2 N/A N/A 1-286 5% Chrysotile
Floor tile mastic 300 ft2 N/A N/A 1-287 3% Chrysotile
Walls Plaster/Sheetrock N/A N/A N/A V Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tiles & above E wall & duct
Pipe insulation < 25 LF FN/A N/A N/A Assumed
1st Floor, N wing, room N1-86D
Floor Rug over tile N/A N/A N/A N/A Non- suspect
12” X 12” floor tile ( white w/ black streaks
560 ft 2 N/A N/A 8-028 10 % Chrysotile
Floor tile mastic 560 ft 2 N/A V 8-029 5% Chrysotile
Walls Plaster/ sheetrock N/A N/A N/A N/A Non- suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non- suspect
Above ceiling tile Pipe insulation 20-25 LF Damaged N/A N/A Assumed
Univents Transite panels 64-128 ft2 Damaged N/A N/A Assumed
Floor
1st Floor, N wing, room just S of N1-81
Floor Rug over floor tile N/A N/A N/A N/A Non-Suspect
12’ x 12’ ( off-white w/ light and dark olive mottles)
160 ft2 N/A N/A 1-286 5% Chrysotile
Floor tile mastic 160 ft 2 N/A N/A 1-287 3% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling Pipe insulation 8-10 LF Damaged N/A N/A Assumed
1st Floor, N wing, room N 1-82
Floor 12” X12” Floor tile ( off-white w/ light & dark olive mottles)
80-100 ft2 N/A 1-286 N/A 5% Chrysotile
Floor tile mastic 80-100 ft2 N/A 1-287 N/A 3% Chrysotile
12” x 12” ceiling tile (white w/ rows of holes) –above 2’ X 4’
N/A N/A N/A Previously tested <1%
1st Floor, N wing, room N1-83
Floor Carpet over 12” X12” floor tile (tan w/ white/dark tan mottles)
250 ft 2 N/A N/A 8-039 None detected
Floor tile mastic 250 ft2 N/A N/A 8-040 2% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
12” X 12” ceiling tiles N/A N/A N/A N/A Non-suspect
Above ceiling tile/plaster ceiling
Pipe insulation (can’t see above plaster)
N/A N/A N/A N/A Assumed
Floor
1st Floor, N wing, room N1-85
Walls Marble/plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile 216 ft2 Damaged N/A 2-121 5% Chrysotile
Comments: No access above ceiling tiles within this area due to the asbestos content of the ceiling tiles.
1st Floor, N wing, room N1-86 and Mechanical room Labeled N1-89 on drawings(which is labeled twice)
Floor 12” X 12” floor tile (white w/tan & dark tan mottles)
960 ft2 N/A N/A 5-69 None detected
Floor tile mastic 960 ft2 N/A N/A 5-70 5% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Ceiling tile - Removed N/A
Above ceiling tile Pipe/fitting insulation (N1-86) 20-25 LF Damaged N/A N/A Assumed
Pipes in Mech N1-89 Valve Fitting Insualtion 1 LF Significant Damage
N/A N/A Assumed
Univents Transite panels 64-128 ft2 Damaged V N/A Assumed
1st Floor, N wing, room N1-89 (Room between N1-86D and N1-79)
Floor 12” X12” floor tile under rug 250 ft2 N/A N/A 1-286 5% Chrysotile Mastic
250 ft2 N/A N/A 1-287 3% Chrysotile
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
In chase Pipe/fitting insulation 20-30 LF Good N/A N/A Assumed
Floor
1st Floor, N wing, room N1-91
Pipe riser Pipe insulation (black mastic over cork)
10 LF Good N/A 6-96 8% Chrysotile
1st Floor, N wing, room N1-92 and N1-93 (bathroom)
Floor 12” X 12” floor tile (gray/green w/ white & gray mottles) - Removed
160ft2 (N1-92) 50ft2 (N1-93)
N/A 1-190 N/A N/A
Floor tile mastic - Removed 160 ft2 N/A 1-191 N/A N/A
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile and plaster
Pipe insulation >30 LF Good N/A N/A Assumed
Univents (N1-92 only) Transite panels 16-32 ft2 Significant damage
N/A N/A Assumed
1st Floor, N wing, room N1-95 and N1-94 (bathroom)
Floor 12” X 12” floor tile (gray/green w/ white & gray mottles)
150 ft2 Good N/A 1-190 5% Chrysotile
Floor tile mastic 150 ft2 N/A N/A 1-191 10% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile (over W wall)
Pipe insulation 20 LF Good N/A N/A Assumed
Floor
1st Floor, N wing, rooms N1-99, N1-100, N1-102A, N1-102, N1-103A, N1-103 and N1-104A
9” X9” floor tile (white w/blue marks)
~160 ft2 /area N/A N/A N/A Assumed
Floor tile mastic ~160 ft2 /area N/A N/A N/A Assumed
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
In chases ( all rooms) & above ceiling tile in 99,102,103A-removed above ceilings
Pipe insulation – 103A No pipe above, 102 8in damage piece B4 chase, 99 can’t see/plaster ceiling
20-30 LF
each
Damaged N/A N/A Assumed
Univents Transite panels (103 & 103A 3 of 4 front panels gone)
16-32 ft2/area Damage N/A N/A Assumed
1st Floor, N wing, rooms N1-104B and N1-104
Floor 12” X 12” floor tile (gray w/ white and dark gray mottles)
160 ft2 /area N/A N/A 8-039 None detected
Floor tile mastic 160 ft2 /area N/A N/A 8-040 2% Chrysotile
9” X 9” floor tile (N1-104B) 4-5 ft2 N/A N/A N/A Assumed
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite Panels 16-32ft2
(104B)
8-16ft2 (104) Damaged N/A N/A Assumed
1st Floor, N wing, room N1-108
Floor Terrazzo tile N/A N/A N/A N/A Non-suspect
Walls Tile/plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Floor
1st Floor, corridor N1-101
12” X12” floor tile (off-white w/ light & dark tan mottles)
1400 ft2 N/A 1-224T N/A None detected
Floor tile mastic 1400 ft2 N/A 1-224M N/A 8% Chrysotile
9” X 9” floor tile (by 104B) 6-8 ft2 N/A N/A N/A Assumed
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
16 ft2 Damaged N/A N/A Assumed
Above E ceiling Pipe insulation in deck - Removed N/A N/A N/A N/A Assumed
1st Floor, N wing, room N1-96A
Floor 12” X 12” floor tile(over hard tile) 160 ft2 N/A 1-225T N/A None detected
Floor tile mastic 160 ft2 N/A 1-225M N/A None detected
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-96
Floor 12” X12” floor tile (over hard tile) 50 ft2 N/A N/A 1-225T None detected
Floor tile mastic 50 ft2 N/A N/A 1-225M None detected
Floor
1st Floor, N wing, room N1-97
Floor 12” X 12” floor tile (over hard tile) 160 ft2 N/A N/A 1-225T None detected
Floor tile mastic 160 ft2 N/A N/A 1-225M None detected
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
1st Floor, N wing, room N1-98
Floor 12” X12” floor tile (over hard tile) 160 ft2 N/A N/A 1-225T None detected
Floor tile mastic 160 ft2 N/A N/A 1-225M None detected
Univents Transite panels 16-32 ft2 Damaged N/A N/A Assumed
1st Floor, N wing, rooms N1-105A and N1-105
Floor 12” X 12” floor tile 160 ft2 /area N/A N/A 1-225T None detected
Floor tile mastic 160 ft2 /area N/A N/A 1-225M None detected
9” X 9” floor tile (under 12” X 12” ) 160 ft2 /area N/A N/A N/A Assumed
Floor tile mastic 160 ft2 /area N/A N/A N/A Assumed
Univents Transite panels (N1-105 missing front panels)
16-32 ft2 Damaged N/A N/A Assumed
1st Floor, N wing, room N1-109
Floor 12” X12” floor tile(tan w/ white & dark tan mottles) - Removed
300 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 300 ft3 N/A N/A N/A N/A
Floor
Ceilings 2’ X4’ ceiling tiles N/A N/A N/A Previously tested <1%
Above ceiling tile (N wall)
Pipe insulation 3 LF Good N/A N/A Assumed
Univents Transite panels (front missing) 16 ft2 Damaged N/A N/A Assumed
Comments: The front of the panels have been removed. The rear panes could not be observed at the time of this inspection and could be present.
1st Floor, N wing, room N1-110
Floor 12” X12” floor tiles - Removed 150 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 150 ft2 N/A N/A N/A N/A
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, rooms N1-111, N1-112, N1-113, N1-114, N1-115, N1-116, N1-119
Floor 12” X 12” floor tile (yellow/orange) - Removed
180 ft2 N/A N/A 8-039 N/A
Floor tile mastic - Removed 180 ft2 N/A N/A N/A N/A
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
16 ft2 / Room Damaged N/A N/A Assumed
Chases Pipe insulation - Assume still there N/A N/A N/A N/A Assumed
Floor
1st Floor, N wing, room N1-120
Floor 12” X12” floor tile - Removed 200 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 200 ft2 N/A N/A N/A N/A
1st Floor, N wing, rooms N1-121, N1-122, N1-123, and N1-124 - Removed
Floor 12” X 12” floor tile 100 ft2/ area 50 ft2 N1-124
N/A N/A 8-039 None detected
Floor tile mastic 100 ft2/ area 50 ft2 N1-124
N/A N/A 8-040 2% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-125
Floor 12” X 12” floor tile - Removed 200 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 200 ft2 N/A N/A N/A N/A
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceiling 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-130
Floor 12” X 12” floor tile - Removed 100 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 100 ft2 N/A N/A N/A N/A
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Floor
1st Floor, N wing, room N1-131
Floor 12” X 12” floor tile - Removed 50 ft2 N/A N/A N/A N/A
Floor tile mastic - Removed 50 ft2 N/A N/A N/A N/A
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, telephone closet (off room N 1-136) and N1-128
Floor 12” X 12” floor ( telephone closet) 9 ft2 N/A N/A N/A Assumed
Floor tile mastic 9 ft2 N/A N/A N/A Assumed
12” X 12” floor tile(N1-128) -
25 ft 2 N/A N/A N/A Assumed
Floor tile mastic - Removed 25 ft2 N/A N/A N/A Assumed
1st Floor, N wing, room N1-32 – Not on prints or Field
Floor Rug over tile N/A N/A N/A N/A Non-suspect
12” X 12” floor tile 160 ft2 N/A N/A N/A Assumed
Floor tile mastic 160 ft2 N/A N/A N/A Assumed
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tiles (N wall)
Pipe insulation 5 LF Damaged N/A N/A Assumed
Floor
1ST Floor, N wing, rooms N1-134, N1-135, N1-136 ( dental area)
Floor Rug over concrete or terrazzo N/A N/A N/A N/A Non-suspect
Walls Sheetrock and joint material N/A N/A 1-189 N/A None detected
Above ceiling tiles (wall by nurse’ station)
Pipe insulation - Removed N/A N/A N/A N/A N/A
1st Floor, halls (in dental areas)
Floor 12” X12” floor tile - Removed N/A N/A N/A N/A N/A
Floor tile mastic - Removed N/A N/A N/A N/A N/A
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ Ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-136A – Area not present
Floor 12” X 12” floor tile 320 ft2 N/A N/A 8-039 None detected
Floor tile mastic 320 ft2 N/A N/A 8-040 2% Chrysotile
Walls Sheetrock N/A N/A 1-189 N/A None detected
Ceilings 2’X4’ ceiling tile N/A N/A N/A N/A Non-suspect
1st Floor, N wing, room N1-137
Floor 12” X 12” floor tile (white w/tan & dark tan mottles)
20 ft2 N/A N/A 5-69 None detected
Floor tile mastic 20ft2 N/A N/A 5-70 5% Chrysotile
Floor
1st Floor, N wing, rooms N1-143, N1-142, N1-141, N1-140, N1-139 and N1-138
Floor Rug over terrazzo N/A N/A N/A N/A Non-suspect
Walls Plaster / sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ x 2’ ceiling tile N/A N/A N/A N/A Non-suspect
Main Chapel and Sacristy
Floor of main chapel Rug over concrete (main area) Altar – rug over concrete
N/A N/A N/A N/A Non-suspect
12” X 12” Floor tile (purple w/ white/dark purple markings)
940 ft2 N/A C-149 N/A None detected
Floor tile mastic 940 ft2 N/A C-159 N/A 2% Chrysotile
Floor of Sacristy 9” X 9“ Floor tile 300 ft2 N/A N/A N/A Assumed
Floor tile mastic 300 ft2 N/A N/A N/A Assumed
Walls Sheetrock/joints N/A N/A N/A Previously tested None detected
Ceiling 2’ X 2’ ceiling tile (tan, rough variegations w/foil backing)
N/A N/A N/A N/A Non-suspect
Sacristy Closet Pipe insulation 30-40 ft Significant damage
N/A N/A Assumed
Eucharist Room (21-3)
Floor Rug over wood underlayment over concrete
N/A N/A N/A N/A Non-suspect
Walls Sheetrock/ Joint N/A N/A N/A Previously tested None detected
Ceilings 2’ X 4’ ceiling tile (off-white, crater-like worm markings)
N/A Good C-148 N/A None detected
Floor
S Office (21-4)
Floor Rug over 9” X 9” floor tile 150 ft2 N/A N/A N/A Assumed
Mastic Assumed
Walls Sheetrock/Joints N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles (Not fire rated) N/A N/A N/A N/A Non-suspect
Hall to Chapel (21-13)
Floor 12” X 12” floor tile/carpet N/A N/A N/A N/A Non-suspect, installed after
Pipes Pipe fitting insulation 1 fitting Good N/A N/A Assumed
NOTE: No suspect asbestos-containing material were observed in rooms C1-17, C1-31, C1-43, C1-44, C1-45,C1-51, C1-52, C1-104, C1-56A, N1-133, N1-132, main hallway in dental areas, and crawlspace behind room C1-22 (mechanical room). The halls within the East wing have been recently renovated – no suspect asbestos-containing materials observed. The Dental Wing was completely renovated since 2005 Inspection
Building 1, Floor 2 - Specific Survey Findings
VA Medical Center, Building No. 1, 2 nd
Floor
1511 Route 22, Suite C24, Brewster, NY 10509 Phone: 845.278.7710 Fax: 845.278.7750
Environmental Health Associates, Inc.
Project: Main Building, 2 nd Floor Inspector(s): James Reber
VA Medical Center Thomas Ferro Wilkes-Barre, PA Date(s): 2/2010-3/2010
LOCATION MATERIAL QUANTITY CONDITION SAMPLE #
HOMOGENEOUS
WITH SAMPLE #
ASBESTOS CONTENT
nd
Floor, Corridor – center/east (service elevator side and small hall to Nuclear Medicine)
Floor 12” X 12” floor tile(light green w/white & dark green mottles)
1100 ft2 good N/A 7-58 15% Chrysotile
Floor tile mastic 1100 ft2 N/A N/A 7-59 10% Chrysotile
Walls Block N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile Pipe insulation – mastic and cork >100 LF Good N/A N/A Assumed
2nd Floor, room C2-02 (No access – Assume materials still present)
Floor Concrete N/A N/A N/A N/A Non-suspect
Walls Block N/A N/A N/A N/A Non-suspect
Ceilings Metal/concrete N/A N/A N/A N/A Non-suspect
NW Corner Pipe insulation 2 LF N/A N/A N/A Assumed
2nd Floor, room C2-3A and C2-3B
Floor Composite/ceramic tile N/A N/A N/A N/A Non-suspect
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ x 4’ ceiling tile N/A N/A N/A N/A Non-suspect
VA Medical Center, Building No. 1, Floor 2
Small closet of NE corner of Liberty Hall, C2-21
Floor 12” X 12” floor tile 16 ft2 N/A N/A 6-103 Assumed
Floor tile mastic 16 ft2 N/A N/A 6-104 Assumed
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings Plaster N/A N/A N/A N/A Non-suspect
2nd Floor, room C2-03
Floor 12” x 12” floor tile (light green w/ white & dark green mottles)
160 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 160 ft2 N/A N/A 7-59 10% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
2nd Floor, room C2-04
Floor 12” X 12” floor tile – replaced w/carpet
N/A
Floor tile mastic –replaced w/carpet N/A
Walls Paneling over plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tiles (white w/worm markings)
N/A N/A N/A N/A Non-suspect
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
In walls Brown tissue paper- like material N/A N/A 2-116 N/A None detected
On walls Plaster (light/soft) N/A N/A 2-117 N/A None detected
Comment: Pipe insulation may be in chase
2nd Floor, room C2-05
12” X 12” floor tile(light green w/white & dark green mottles)
168 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 168 ft2 N/A V 7-59 10% Chrysotile
Walls Tile/plaster/paneling N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (off white w/ pinhole perforations & crater worm markings)
N/A N/A 2-120 N/A None detected
2’ X 4’ ceiling tile (off-white w/pinholes & pockmarks)
N/A N/A N/A 2-123 None detected
2nd Floor, room C2-05A
Floor 12” X 12” floor tile (off –white w/ white & brown streaks)
332 ft2 N/A 2-118 N/A <1% Chrysotile
Floor tile mastic 332 ft2 N/A 2-119 N/A 5% Chrysotile
Walls Plaster/sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile Pipe insulation (aircell) 35-40 LF Damaged N/A N/A Assumed
2nd Floor, room C2-05B
Floor 12” X12” floor tile (white w/brown streaks)
192 ft2 N/A N/A 6-103 5% Chrysotile
Floor tile mastic 192 ft2 N/A N/A 6-104 5% Chrysotile
Walls Sheetrock joint material N/A N/A 2-118 N/A None detected
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Above ceiling tile Pipe insulation 28 LF Good N/A N/A Assumed
2nd Floor, hall by rooms C2-05A and 2-130
12” X12’ floor tile (light green w/white & dark green mottles)
385 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 385 ft2 N/A N/A 7-59 10% Chrysotile
Walls Sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ x 4’ ceiling tile (pinhole perforations & worm markings
N/A N/A N/A 2-123 None detected
Above ceiling tile Pipe insulation <10 LF Damaged N/A N/A Assumed
2nd Floor, room C2-06
Floor Ceramic tile N/A N/A N/A N/A Non-suspect
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile 198 ft2 N/A N/A N/A Non-suspect
Univents Transite Panels 8-16 ft2 Damaged N/A N/A Assumed
Comment: Pipe insulation in chase - NE
2nd Floor, rooms C2-07 & C2-08
Floor Rug over floor tile N/A N/A N/A N/A Non-suspect
12” X 12” Floor tile 144 ft2 / area N/A N/A N/A Assumed
Floor tile mastic 144 ft2 / area N/A N/A N/A Assumed
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X4’ ceiling tile( pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Above plaster ceiling (room C2-08 & C2- 07)
Pipe insulation 30 – 35 LF Significant damage
N/A N/A Assumed
C2-09 and C2-10 – Probable asbestos pipe insulation in walls.
C2-11 (corridor) – 12” X 12” green floor tile (7-58: 15% Chrysotile) and mastic (7-59: 10% Chrysotile) – 300 ft2 - Good
2nd Floor, Liberty Hall, room C2-14
Floor Ceramic Tile N/A N/A N/A N/A Non-suspect
Walls Sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (off-white w/ sparse pinhole perforations & worm markings)
3500 ft2 N/A 2-121 N/A 5% Chrysotile
Above ceiling tile (N wall)
Pipe insulation (black mastic over cork)
N/A Good N/A 6-96 8% Chrysotile
Pipe insulation (aircell) N/A Good N/A N/A Assumed
Comment: Cannot check above ceiling tiles because it will disturb ACM
2nd Floor, room C2-13 (Credit Union) and C2-12
Floor Rug over concrete N/A N/A N/A N/A Non-suspect
Walls Sheetrock joint material N/A N/A N/A Previously tested <1%
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Plaster N/A N/A N/A N/A Non-suspect
Vertical chase Pipe insulation N/A N/A N/A N/A Assumed
2nd Floor, rooms C2-14B, C2-14C, C2-14D, C2-14E, and C2-14F
Floor Rug over concrete/ceramic tile N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock joint material N/A N/A N/A N/A Non-suspect
2nd Floor, room C2-15
Floor Rig over concrete N/A N/A N/A N/A Non-suspect
Walls Sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
128 ft2 N/A N/A 2-123 None detected
Above ceiling tile (over N wall)
Pipe insulation 4 LF Good N/A N/A Assumed
2nd Floor, room C2-16
Floor Rug over ceramic tile N/A N/A N/A N/A Non-suspect
Walls Sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ x 4’ ceiling tile (pinhole perforations & worm markings)
144 ft2 N/A N/A 2-123 None detected
Above ceiling tile (N side)
Pipe insulation 10 LF Good N/A N/A Assumed
2nd Floor, room C2-17, C2-18, C2-19 (C2-19 not found)
Floor Ceramic Tile N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 Non-suspect
Above ceiling and in chase( has cork pipe aircell)
Pipe insulation (aircell, mastic cork pipe)
>50 LF
aircell
>40 LF cork N/A N/A N/A Assumed
2nd Floor, pipe chase by C2-22 (electrical closet) (Room was not found)
Pipe Pipe insulation (black mastic over cork)
3 LF N/A N/A 6-96 8% Chrysotile
2nd Floor, room C2-22
Floor Ceramic tile N/A N/A N/A N/A Non-suspect
12” X 12” floor tile (tan w/white & dark tan mottles) – bathroom
40 ft2 N/A N/A 8-039 None detected
Floor tile mastic – bathroom 40 ft2 Good N/A 8-040 2% Chrysotile
Ceilings 2’ X4’ ceiling tile N/A N/A N/A N/A Non-suspect
2nd Floor, room C2-23
Floor 12” X 12” floor tile – new N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’X4’ ceiling tile (pinhole perforations w/ worm markings)
N/A N/A N/A 2-123 None detected
Univents Transite panels 24-48 ft2 Damaged N/A N/A Assumed
Above ceiling tile Pipe insulation (aircell) 16 LF Good N/A N/A Assumed
Pipe insulation (black mastic over cork and MAG)
12 LF Damaged N/A 6-96 8% Chrysotile
Threshold of C2-24 and C2-25 – 3 ft2 - 12” X 12” Floor tile (blue green) and floor tile mastic.
2nd Floor, room C2-24
Floor Terrazzo tile N/A N/A N/A N/A Non-suspect
Walls Tile /plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’X4’ ceiling tile (off-white w/perforations &worm markings)
648 ft2 N/A N/A 2-128 None detected
Univents Transite panels 40 – 80 ft2 Damaged N/A N/A Assumed
Above ceiling and in chase
Pipe insulation >20 LF Good N/A N/A Assumed
2nd Floor, room C2-25
Floor Rug 12” X 12’ pads (brown) 258 ft2 N/A N/A N/A Non-suspect
Mastic 258 ft2 N/A N/A N/A >1%
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
2nd Floor, room C2-27A Mechanical
Pipes Pipe insulation (black mastic over cork)
12 LF Damaged N/A 6-96 8% Chrysotile
2nd Floor, room C2-28
Floor Tile N/A N/A N/A N/A Non-suspect
Walls Tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Above ceiling tile/plaster
Pipe insulation 25-30 LF Good N/A N/A Assumed
Univent Transite panels (front missing) 8 ft2 N/A N/A N/A Assumed
2nd Floor, rooms C2-29 and C2-30
Floor 12”X 12” floor tile under rug (room C2-29 & C2-30)
420 ft2 N/A N/A Previously tested positive >1%
Floor tile mastic (room C2-29)` 420 ft2 N/A N/A Previously tested positive >1%
Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels 32-64 ft2/area Damaged N/A N/A Assumed
Above plaster in C2-
Pipe insulation 16-20 LF Damaged N/A N/A Assumed
2nd Floor, rooms C2-33A
Floor 12” X 12” floor tile – new N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ –new N/A N/A N/A N/A Non-suspect
Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
16 ft2 N/A N/A N/A Assumed
2nd Floor, room C2-30A
Floor Rug over 12” X 12” floor tile/mastic N/A N/A N/A N/A >1%
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
2nd floor, room C2-31
Floor Rug over floor tile N/A N/A N/A N/A Non-suspect
12” X 12” floor tile (off-white) 880 ft2 N/A 2-131 7-59 5% Chrysotile
Floor tile mastic 880 ft2 N/A N/A N/A Assumed
Walls Wood paneling N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (off-white w/ perforations & worm markings)
N/A N/A N/A N/A Non-suspect
Univents Transite panels 24-48 ft2 Damaged N/A N/A Assumed
2nd Floor, room C2-33
Floor Rug over floor tile No rug N/A N/A N/A N/A Non-suspect
12” X 12” floor tile (off-white) 120 ft2 Good 2-132 N/A 3% Chrysotile
Floor tile mastic 120 ft2 N/A 2-133 N/A 3% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 20 – 40 ft 2 Damaged N/A N/A Assumed
E Wall Pipe insulation 8 linear feet N/A N/A N/A Assumed
2nd floor, Room C2-33B through C2-43
Floor 12” X 12” floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
2nd Floor, room C2-43A – No suspect material
2nd Floor, C2-44
Floor Terrazzo Tile N/A N/A N/A N/A Non-suspect
Walls Tile/sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile 9pinhole perforations & worn markings
N/A N/A N/A 2-123 None detected
2nd Floor, hall by service elevator
Floor 12’ X 12” floor tile (light green W/ white & dark green mottles)
200 ft2 N/A N/A 7-58 15% Chrysotile
Floor mastic 200 ft2 N/A N/A 7-59 10% Chrysotile
Walls Brick/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Pipe insulation in chase behind elevator #2 – 15LF - Damaged
2nd Floor, room C2-46 (Electrical closet)
Pipe Pipe insulation (black mastic over cork)
12 LF Good N/A 6-96 8% Chrysotile
Pipe Pipe/fitting insulation on fiberglass lines
4 fittings Good N/A N/A Assumed
C2-106A and B, Pipe Room to N of 106B, and C2-107 – No exposed suspect asbestos containing materials observed.
2nd Floor, room C2-47
Floor 12” X 12” floor tile (chocolate w/white & dk brown marble effect)
120 ft2 Good N/A 7-86 None detected
Floor tile mastic 120 ft2 N/A N/A 7-87 5% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels 12-24 ft2 Damaged N/A N/A Assumed
2nd Floor, room C2-118 and C2-121 (Library area)
Floor` Rug over N/A N/A N/A Non-suspect
Mastic N/A N/A 2-112 None detected
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceiling 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels
32-64ft
(C2-118) 56-112 ft
(C2-121)
Damaged N/A N/A Assumed
C2-129 and C2-130 – No exposed suspect asbestos materials observed. (Not found)
Recreation Room
Floor 12” X 12” floor tile (off-white with brown mottles)
2000 ft2 N/A N/A
Previously tested positive
>1%
Mastic 2000 ft2 N/A N/A
Previously tested positive
>1%
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
2nd Floor, N wing, room N2-48 ( Labeled N2-49A on drawings)
Floor 12” X 12” floor tile- green mottles) Not there – newer 12” X 12”
180-200 ft2 N/A N/A
Mastic 180-200 ft2 N/A N/A
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
12-24 ft2 Damaged N/A N/A Assumed
Above ceiling tiles Pipe insulation (aircell) – removed
2nd Floor, room N2-49
Floor Ceramic Tile N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock joint material/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Concrete N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
36 ft2 N/A N/A N/A Assumed
Utility room off C49 9 (N2-49B)
Pipe insulation (aircell) 10 LF Good N/A N/A Assumed
2nd floor, N wing, room N2-50
Floor Ceramic Tile N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock joint material/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Univents Transite panels (front panels missing)
20 ft2 N/A N/A N/A Assumed
SW Chase Pipe insulation >20 LF N/A N/A N/A Assumed
2nd Floor, N wing, N2-48A – Turned into mechanical room.
Floor 12” X 12” floor tile – green mottled)
Mastic -Removed
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Pipes in N wall Pipe insulation/fitting 12 LF Significant damage
2nd Floor, N wing, room N2-53
Floor Ceramic tile N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
40 ft2 N/A N/A N/A Assumed
Chase – NE corner Pipe insulation >12 LF N/A N/A N/A Assumed
2nd Floor, N wing, room N2-55 & electrical room
Floor Ceramic tile N/A N/A N/A N/A Non-suspect
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings Plaster N/A N/A N/A N/A Non-suspect
2nd Floor, N wing, room N2-56 (Electrical room)
Floor Concrete/metal N/A N/A N/A N/A Non-suspect
Walls Block N/A N/A N/A N/A Non-suspect
Vertical Chase Pipe insulation 9black mastic over cork)
12 LF Good N/A 6-96 8% Chrysotile
Vertical Chase Duct insulation (black mastic over cork)
100 ft2 Good N/A 6-96 8% Chrysotile
2nd floor, N wing, room N2-58
Floor 12” X 12” and 2’ X 2’ N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
8 ft 2 N/A N/A N/A Assumed
2nd Floor, N wing, room N2-60 – No exposed suspect asbestos materials observed.
2nd Floor, N wing, room N2-59
Floor 12” X 12” Floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Univents Transite panels 32 ft2 N/A N/A N/A Assumed
Comments: The front transite panels have been removed. The rear panels could not be observed at the time of this inspection and could be present.
2nd Floor, N wing, rooms N2-64 and N2-64A
Floor 12” X 12” floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings) – N2-64
N/A N/A N/A 2-123 None detected
2’ X 4’ ceiling tile – N2-62 N/A N/A N/A N/A Non-suspect
Above ceiling tile Pipe fitting - Removed 1 N/A N/A N/A Assumed
Univents Transite panels (front panels missing)
36 ft2 N/A N/A N/A Assumed
2nd Floor, N wing, rooms N2-66 and bathroom N2-67
Bathroom - in chases Pipe insulation >40 LF Significant damage
N/A N/A Assumed
Univents Transite panels (N2-67) 8 ft2 N/A N/A N/A Assumed
Comments: The front transite panels have been removed. The rear panels could not be observed at the time of this inspection and could be present.
2nd Floor, N wing, room N2-68
12” X 12” floor tile (tan w/white & dark tan mottles)
250-300 ft2 N/A N/A 8-039 None detected
Floor tile mastic 250-300 ft2 N/A N/A 8-040 2% Chrysotile
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing
24 ft2 N/A N/A N/A Assumed
NE Corner chase Pipe insulation – Same chase as N2-70
10-20 LF Good N/A N/A Assumed
2nd Floor, N wing, room N2-70
Floor 12” X 12” floor tile (tan w/white & dark tan mottles)
36 ft2 good N/A 8-039 None detected
Floor tile mastic 36 ft2 N/A N/A 8-040 2% Chrysotile
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
16 ft2 N/A N/A N/A Assumed
S wall Pipe insulation 10-20 LF Good N/A N/A Assumed
2nd Floor, N wing, room N2-71
Floor 12” X 12” floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
24 ft2 N/A N/A N/A Assumed
Comments: The front transite panels have been removed. The rear panels could not be observed at the time of this inspection and could be present.
2nd Floor, N wing, room N2-74
Floor Ceramic tile N/A N/A N/A 8-039 Non-suspect
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels ( front panels missing)
8 ft2 N/A N/A N/A Assumed
Above ceiling & in chase
Pipe insulation 45 LF Good N/A N/A Assumed
2nd floor, N wing, room N2-75
Floor 12” X 12’ floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 44’ ceiling tile (pinhole perforations & worm markings
N/A N/A N/A 2-123 None detected
Univents Transite panels 32 ft2 N/A N/A N/A Assumed
Over ceiling tile Duct insulation – removed N/A N/A N/A N/A N/A
Comments: The front transite panels have been removed. The rear panels could not be observed at the time of this inspection and could be present.
2nd Floor, N wing, bathroom at E end of radiology hall (Labeled N2-66)
Floor 12” X 12” floor tile (tan w/white and dk tan mottles) –Removed Non-suspect concrete
Floor tile mastic - Removed
Walls Sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2” X 2’ ceiling tile (off-white w/pinhole perforations & small crater)
36 ft2 Good 2-127 N/A None detected
Above ceiling tile Duct insulation – removed N/A N/A N/A N/A N/A
2nd Floor, N wing, room N2-77 and N2-77A
Floor 12” X 12” floor tile N/A N/A N/A N/A Non-suspect
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 Non-suspect
Univents Transite panels (front panels missing)
16 ft2 N/A N/A N/A Assumed
In walls Pipe insulation (Assume chases) N/A N/A N/A N/A Assumed
2nd Floor, N wing, rooms N2-79 and N2-80
Floor 12” X 12” floor tile (light green w/white & dk green mottles)
320 ft2 Good N/A 7-58 15% Chrysotile
Floor tile mastic 320 ft2 N/A N/A 7-59 10% Chrysotile
Walls Plaster/sheetrock N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing)
24 ft2 N/A N/A N/A Assumed
Chase in N2-79 Pipe insulation 20-30 LF N/A N/A N/A Assumed
2nd Floor, N wing, room N2-83A
Floor 12” X 12’ floor tile(light green w/white & dark green mottles)
240 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 240 ft2 N/A N/A 7-59 10% Chrysotile
Walls Plaster/sheetrock joint material N/A N/A N/A N/A Non-suspect
Ceilings 2’X4’ ceiling tile (pinhole perforations & worm markings)
N/A N/A N/A 2-123 None detected
Concrete N/A N/A N/A N/A Non-suspect
Univents Transite panels 32 ft2 N/A N/A N/A Assumed
Comments: The front transite panels have been removed. The rear panels could not be observed at the time of this inspection and could be present.
2nd Floor, N wing, rooms N2-84 and N2-84A
Floor 12” X 12” floor tile 300 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 300 ft2 N/A N/A 7-59 10 % Chrysotile
Ceilings 2’ X 4’ ceiling tile (pinhole perforation & worm markings)
N/A N/A N/A 2-123 None detected
Univents Transite panels 8 ft2 (N2-84) 16 ft2 (N2-
84A) N/A N/A N/A Assumed
Above ceiling tile Duct insulation (black mastic over cork)
7 LF N/A N/A 6-96 8%Chrysotile
Chase in N2-84 Pipe insulation >40 LF N/A N/A N/A Assumed
2nd Floor, N wing, main hall (radiology area)
12” X 12” floor tile (light green w/white and dk green mottles)
900 ft2 N/A N/A 7-58 15% Chrysotile
Floor tile mastic 900 ft2 N/A N/A 7-59 10% Chrysotile
Ceilings 2’ X 2’ ceiling tile N/A N/A N/A N/A Non-suspect
Concrete N/A N/A N/A N/A Non-suspect
Above ceiling tile Duct insulation – removed N/A N/A N/A N/A N/A
2nd Floor, N wing, room N2-85 (files)
Floor-most of floor tiles in this room are new
12” X 12” floor tile (chocolate w/white & dk brown marble effect)
126 ft2 N/A N/A 7-87T None Detected
Floor tile mastic 126 ft2 N/A N/A 7-87M 5% Chrysotile
Walls Plaster/sheetrock/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels (front panels missing on some, present on others)
64-100 ft2 Damaged N/A N/A Assumed
Pipe insulation 8 LF Damaged N/A N/A Assumed
Above ceiling tile Duct insulation – removed N/A N/A N/A N/A N/A
2nd Floor, N wing, room N2-95 and N2-96 – Newly renovated – no suspect asbestos materials observed
2nd Floor, N wing, room N2-97A and N2-97B
Floor 12” X 12” floor tile (green with mottles)
400 ft2 (97A) 220 ft2 (97B)
Good N/A 7-58 15% Chrysotile
Floor tile mastic 400 ft2 (97A) 220 ft2 (97B)
N/A N/A 7-59 10% Chrysotile
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Univents Transite panels 36-72ft2 (97A) 24-48ft2 (97B)
Damaged N/A N/A Assumed
NW Chase in 97A Pipe insulation >30 LF N/A N/A N/A Assumed
2nd Floor, N wing, room N2-98 and N2-99
9” x 9” floor tile (brown w/white & burnt sienna) (N2-98 only)
175 ft2 Good N/A N/A Assumed
Floor tile mastic 175 ft2 N/A N/A N/A Assumed
Walls Plaster/tile N/A N/A N/A N/A Non-suspect
Ceilings 2’ X 4’ ceiling tile N/A N/A N/A N/A Non-suspect
Plaster N/A N/A N/A N/A Non-suspect
Univents Transite panels 8-16 ft2 Damaged N/A N/A Assumed
Above ceiling tile Pipe insulation (aircell) 25 LF Good N/A N/A Assumed
2nd Floor, N wing, room N2-100 and N2-101
Floor 9” X 9” floor tile (brown w/white marks and burnt sienna) - N2-101 only
175 ft2 Good N/A N/A Assumed
Floor tile mastic 175 ft2 N/A N/A…