Attachment 5- Drawings - EMHC - Part 4 of 4.pdf

PDF 9 MB Posted

Attached to
Z2DA--Expand Mental Health Clinic Construction Wilkes Barre (VA-24-00034565)
Solicitation number
36C77624R0079_1
Issued by

About this file

This document appears to be a set of drawings and specifications related to the "Expand Mental Health Clinic" construction project at the Wilkes-Barre VA Medical Center in Wilkes-Barre, Pennsylvania. The project is a competitive Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, solicitation number 36C77624R0079_1. The contractor will be required to provide all labor, project management, materials, tools, supplies, and equipment to complete the necessary work. The drawings cover mechanical, electrical, and lighting plans for the first and second floors, as well as electrical schedules and details. The project is for the Department of Veterans Affairs Technology Acquisition Center Austin.

View the file

Other files

File Type Posted
Amendment 0003 36C77624R0079.pdf PDF
Amendment 0002 Attachment 1 Additional RFIs 7 9 24.docx DOCX document
Amendment 0002 36C77624R0079.pdf PDF
Amendment 0002 Attachment 2 6007 Wilkes-Barre Geotechnical Report.pdf PDF
Amendment 0001 Attachment 3 -VA Signage Design Manual.pdf PDF
Amendment 0001 36C77624R0079.pdf PDF
Amendment 0001 Attachment 1 RFIs - Expand Mental Health Wilkes-Barre Final.docx DOCX document
Amendment 0001 Attachment 4 - Const Wage Determination Luzern 6.28.24.pdf PDF
Amendment 0001 Attachment 5 -Site Visit SIgn In Sheet.pdf PDF
Amendment 0001 Attachment 2 -Adendum 01.zip ZIP file
Attachment 9 -Site Visit Instructions Wilkes-Barre.docx DOCX document
36C77624R0079_1.pdf PDF
Attachment 11- Site Map.pdf PDF
Attachment 3- Drawings - EMHC - Part 2 of 4.pdf PDF
Attachment 12 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 2- Drawings - EMHC - Part 1 of 4.pdf PDF
Attachment 7- Construction Wage Determination 5.31.pdf PDF
Attachment 1- Specs - EMHC.pdf PDF
Attachment 4- Drawings - EMHC - Part 3 of 4.pdf PDF
Attachment 9 -Site Visit Instructions Wilkes-Barre.docx DOCX document
Attachment 8- Service Wage Determination.pdf PDF
Attachment 10- Brand Name_Redacted.pdf PDF
Attachment 6- Asbestos Reports - Wilkes-Barre.pdf PDF
Show all 23

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

R

J J J

J

J

48"

GFI

GFI

G

FI

GFI

GFI

48"

GFI

48"

GFI

AC

AC

48"

GFI

GFI

GFI

GFI

GFI

GFI

J

J

J

J

J

J

J

J

J

J

J

S SS

S S

S S

S SS

S S

S S

D E

TRAINING

ROOM

C2-211

OFFICE

C2-207

HOLDING

C2-205

INTERVIEW

ROOM

C2-206

WOMEN'S

LOCKERS

C2-214

OFFICE

C2-202

ARMORY

C2-210

BREAK

AREA

C2-216

CORRIDOR

C2-200

OFFICE

C2-209

MEN'S TLT

C2-213

MEN'S

LOCKERS

C2-212

WOMEN'S

TLT

C2-215

OFFICE

C2-208

ENTRANCE

C2-204

RECEPTION

C2-203

OFFICE

C2-201

WEAPONS

C2-210A

TOUCHDOWN

A5-005

EXAM

RM

A2-007

EXAM

RM

A2-011

TOILET

A2-009A

TOILET

A2-009

OFFICE

A2-010

STAFF

TOILET

A2-008

WAITING

RM

A2-003

TOILET

A2-05A CHECK-IN

A2-004

CLEAN

LINEN

A2-18

SOILED

A2-017

CORRIDOR

A2-013

A2-002

ELECTRICAL

A2-119

ELEV

S-1

ELEV

S-2

ELEV

S-3

LOCKER

RM

C2-115

STAIR

CORRIDOR

C2-11

OFFICE

C2-04

OFFICE

C2-03

MECH

C2-10

ELEC

C2-02

C2-09

STORAGE

C2-05B

OFFICE

C2-05A

TOILET

2-130

STAIR

2-002

STAIR

CORRIDOR

A2-001

CORRIDOR

C2-32

A B CA.2 B.3

9.3

10.6

EXISTING

PANEL 'W2-E'

EXISTING

PANEL 'W2P'

EXISTING

PANEL 'SLP2'

'SLP2B'- 1

EXISTING

PANEL 'W2-EL'

'W2-E'- 2

'W2-E'- 6

'W2-E'- 18

'W2-E'- 10

'W2-E'- 12

'W2-E'- 14

'W2-E'- 8

'W2-E'- 16

'W2-E'- 4

'W2-E'- 3 'W2-E'- 24

'W2-E'- 1

'W2-E'- 22

'W2-E'- 5

PANEL 'SLP2A' PANEL 'SLP2B'

TRANSFORMER

'SLP2T'

AHU

ENCLOSURE

C2-211A

'W2-EL'- 13

'W2-E'- 20

AREA OF WORK LIMIT LINE

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:4

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EP102B

SECOND FLOOR POWER PLAN - AREA

B

13 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

SECOND FLOOR POWER PLAN - AREA B

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

A. COORDINATE ELECTRICAL INSTALLATION WITH

CIVIL & STRUCTURAL DRAWINGS INCLUDED AS

PART OF THIS CONSTRUCTION DOCUMENT SET.

B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION

EQUIPMENT DIMENSIONS ARE BY: EATON.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

EQUIPMENT THAT FITS WITHIN THE SIZE

CONSTRAINTS WITH PROPER CLEARANCES.

CONTRACTOR TO FURNISH SHOP DRAWINGS

SHOWING HOW EQUIPMENT PROPOSED WILL FIT

WITHIN THE SPACE CONSTRAINTS ALLOWED

WHILE MAINTAINING PROPER CLEARANCES PER

NEC-110.31, 110.32, AND MANUFACTURER

RECOMMENDATIONS.

C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS

SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C

(UNLESS OTHERWISE NOTED)

D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,

DUCT BANK, AND ELECTRICAL DETAILS FOR

INFORMATION REGARDING POWER FEED

CONSTRUCTION.

E. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.

LEGEND

1 EXISTING RECEPTACLE LOCATION. MAINTAIN

EXISTING BOX, REPLACE DEVICE AND

FACEPLATE. RECIRCUIT AS SHOWN.

2 CONNECT TO EXISTING NORMAL POWER CIRCUIT

SERVING THIS SAME AREA RETAINED DURING

DEMOLITION.

3 PROVIDE LIGHTNING PROTECTION SYSTEM ON

ROOF OF NEW AHU ENCLOSURE. CONNECT TO

EXISTING BUILDING LIGHTNING PROTECTION

SYSTEM.

4 PROVIDE JUNCTION BOXES FOR WATER CLOSET

AND LAVATORY SENSORS; CONNECT TO EXISTING

NORMAL POWER 120V CIRCUIT SERVING THIS

SAME AREA RETAINED DURING DEMOLITION, WITH

2-12 AWG, 1-12 AWG IN 3/4" CONDUIT.

COORDINATE LOCATION AND ELECTRICAL

REQUIREMENTS WITH PLUMBING CONTRACTOR.

5 PROVIDE JUNCTION BOXES AND 120V 20A CIRCUIT

FOR PACS DOOR POWER WITH 2-12 AWG, 1-12

AWG EG IN 3/4" CONDUIT.

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

2/20/2024

SOL# 36C77624R0079 Project # 693-352 Expand Mental Health Clinic Construction- Wilkes-Barre, PA

UP

M

M M

M

M

E

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M

M M

M

M

M

M

M

E

E

E

E

E

E E

E

M

MM

M

M

M E

M

J

E

M

M

M

N P Q R S T U V

V.9U.4

15.1

16.3

O

OFFICE/

CONSULT

C1-124

OFFICE/

CONSULT

C1-122

OFFICE/

CONSULT

C1-115OFFICE/

CONSULT

C1-114

OFFICE/

CONSULT

C1-113

OFFICE/

CONSULT

C1-112

MH

WAITING

C1-100

OFFICE/

CONSULT

C1-153 OFFICE/

CONSULT

C1-152

OFFICE/

CONSULT

C1-150

OFFICE/

CONSULT

C1-151

OFFICE/

CONSULT

C1-130

OFFICE/

CONSULT

C1-131

OFFICE/

CONSULT

C1-135

OFFICE/

CONSULT

C1-136

OFFICE/

CONSULT

C1-137

OFFICE/

CONSULT

C1-138

OFFICE/

CONSULT

C1-139

FAMILY

CONSULT

C1-140

OFFICE/

CONSULT

C1-129

OFFICE/

CONSULT

C1-128

OFFICE/

CONSULT

C1-127

GROUP

THERAPY

C1-126

STAFF

BREAK

ROOM

C1-161

MECHANICAL

C1-116

CORRIDOR

C-102

PATIENT

TOILET

C1-148

PATIENT

TOILET

C1-147

OFFICE/

CONSULT

C1-132

OFFICE/

CONSULT

C1-133

OFFICE/

CONSULT

C1-145

OFFICE/

CONSULT

C1-146

OFFICE/

CONSULT

C1-121

ELEC

C-101B

TELE-

HEALTH

C1-101

OFFICE/

CONSULT

C1-120

ELECTRICAL

C1-117OFFICE/

CONSULT

C1-119

ELEC

C1-67

MECH

C1-66

STAIR

STOR

C1-125

FAMILY

CONSULT

C1-149

NURSE

WORK

AREA

(7

NURSES)

C1-109

NURSE

WORK

AREA

C1-102

RECEPTION

C1-163

EXAM/

OFFICE/

CONSULT

C1-104

OFFICE/

CONSULT

C1-111

OFFICE/

CONSULT

C1-110

EXAM/

OFFICE/

CONSULT

C1-106

OFFICE/

CONSULT

C1-143

ELEC.

C1-118

OFFICE/

CONSULT

C1-123

EXAM/

OFFICE/

CONSULT

C1-105

VITALS

C-102B

SUITE

ACCESS

C-103A

TELE-

HEALTH

C1-103

SUITE

ACCESS

C-104

STAFF

LOCKERS

C1-160

FAMILY

CONSULT

C1-134

STOR

C1-141

MSA

C1-162

CORRIDOR

C-107

CORRIDOR

C-106

CORRIDOR

C-105

TR

C1-100A

CORRIDOR

C-101

MECH

C1-83

ELEV

LOBBY

C1-56C

STAFF TLT

C1-107

STAFF TLT

C1-108

OFFICE/

CONSULT

C1-142

OFFICE/

CONSULT

C1-144

HAC

C1-158

MEDS

C1-157

NURSE

WORK

AREA(1)

C-104A

EXAM/INJ

NURSE

OFFICE

C1-156

PROCEDURE/

TMS

C1-154STERILE

SUPPLY

C1-155

1E-VAV-2 1E-VAV-3

1E-VAV-5 1E-VAV-6 1E-VAV-8

1E-VAV-7

1E-VAV-9

1E-VAV-4

1E-VAV-16

1E-VAV-13

1E-VAV-11

1E-VAV-12

1E-VAV-14

1E-VAV-34

1E-VAV-35

1E-VAV-36 1E-VAV-37

1E-VAV-33

1E-VAV-32

1E-VAV-31

1E-VAV-15

1E-VAV-17 1E-VAV-18

1E-VAV-29

1E-VAV-20

1E-VAV-19

1E-VAV-27 1E-VAV-21

1E-VAV-25

1E-VAV-22

1E-AHU-1

1E-RF-1

STAIR

ELEC

C1-76

MECH

C1-78

MECH

ELEV

ELEV

ELEV

ELEV

ELEV

MECH

C1-22G

MECHANICAL

BASEMENT

ROOF

CRAWL

SPACE

CRAWL

SPACE

BASEMENT

ROOF

BASEMENT

ROOF

1E-VAV-28

1E-VAV-23

1E-VAV-24

1E-VAV-26

'LP-3'- 5

1E-VAV-1

1E-VAV-10

'LP-3'- 8

'LP-3'- 7

'LP-3'- 2

14.6

1E-EF-2

1E-EF-1

1E-EF-3

1E-OU-21E-OU-1

1E-IU-2

1E-IU-1

1E-CP-1

1E-VAV-30

'A'- 14,16

'B'- 4,6

'LP-3'- 12

'LP-3'- 3

'LP-3'- 4

'LP-3'- 13

'LP-3'- 30

'ELP1'- 22,24,26

'ELP1'- 21,23,25

'LP-3'- 34

'LP-3'- 6

'LP-3'- 9

B A

B A

M A

T C

H L

IN

E

M A

T C

H L

IN

E

16.6

15.9

15.7

14.8

T.5S.6S.4 V.4V.1S.1

AREA OF WORK LIMIT LINE

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:5

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EM101A

FIRST FLOOR MECHANICAL POWER

PLAN - AREA A

14 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

1 RADIATOR CONTROL VALVE PANEL, PROVIDE 20A

120V CIRCUIT WITH 2-12 AWG, 12 AWG EG, IN 3/4"

CONDUIT. COORDINATE LOCATION AND POWER

REQUIREMENTS WITH MECHANICAL

CONTRACTOR.

2 CONNECT TO EXISTING AHU SUPPLY FAN CIRCUIT

RETAINED DURING DEMOLITION. REPLACE

EXISTING CIRCUIT BREAKER WITH A 3P-40A .

PROVIDE FUSIBLE DISCONNECT FUSED PER

NAMEPLATE.

3 CONNECT TO EXISTING AHU RETURN FAN CIRCUIT

RETAINED DURING DEMOLITION. PROVIDE

FUSIBLE DISCONNECT FUSED PER NAMEPLATE.

Scale: 1/8" = 1'-0"

FIRST FLOOR MECHANICAL POWER PLAN - AREA A

NORTH

0 4 8 16

A. COORDINATE ELECTRICAL INSTALLATION WITH

CIVIL & STRUCTURAL DRAWINGS INCLUDED AS

PART OF THIS CONSTRUCTION DOCUMENT SET.

B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION

EQUIPMENT DIMENSIONS ARE BY: EATON.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

EQUIPMENT THAT FITS WITHIN THE SIZE

CONSTRAINTS WITH PROPER CLEARANCES.

CONTRACTOR TO FURNISH SHOP DRAWINGS

SHOWING HOW EQUIPMENT PROPOSED WILL FIT

WITHIN THE SPACE CONSTRAINTS ALLOWED

WHILE MAINTAINING PROPER CLEARANCES PER

NEC-110.31, 110.32, AND MANUFACTURER

RECOMMENDATIONS.

C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS

SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C

(UNLESS OTHERWISE NOTED)

D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,

DUCT BANK, AND ELECTRICAL DETAILS FOR

INFORMATION REGARDING POWER FEED

CONSTRUCTION.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

DN

E

E

E

E

E

M

M

M M

M

M

E

S SS S S

S S

S SS S

S

S

S

S S

S S

S

S

S

S

S S

S S

S

S

S

S S

S S

S S

S S

S

S

D E F H J L MG

GROUP

MEETING

C1-65

ELEVATOR

LOBBY

C1-75

CORRIDOR

C-100

CORRIDOR

C1-69

STAIR

MECH

C1-83

CORRIDOR

C1-18

CORRIDOR

C1-16

CORRIDOR

C1-13

STORAGE

C1-65B

CONF

ROOM

A1-10

OFFICE

A1-09

OFFICE

A1-09A

EXAM

A1-08

EXAM

A1-11

EXAM

A1-14

EXAM

A1-16

EXAM

A1-07

EXAM

A1-06

EXAM

A1-20

EXAM

A1-15

EXAM

A1-12

EXAM

A1-23

CLEAN

LINEN

A1-02

T L T

A -2 A

EXAM

A1-27

ELEC

A1-03

ELEC

A1-30

ELEV

S-1

ELEV

S-2

ELEV

S-3

ELEV

P-3

ELEV

P-2

ELEV

P-1

CORR

A1-01

ATRIUM

CORR

A1-04

CORR

A1-13

STAIR

T L T

A -0 A

STAIR

VOLUNTARY

C1-77

STOR

C1-78A

ELEC

C1-76

MECH

C1-78

MECH

ELEV

ELEV

ELEV

ELEV

IT

C1-21B

IT

C1-21C

IT

C1-22E

MECH

C1-22G

CRAWL

SPACE

STAIR

ELEV

LOBBY

A1-31A

SOILED

LINEN

A1-29

MECH

C1-04A

ELEC

C1-04

ELEC

C1-17A

ELEC

C1-17

A1-05

A1-28

CORR

A1-22A

HAC

A1-26

A1-22B

21-3

21-4

OFFICE

C1-74

OFFICE

C1-74A

OFFICE

C1-73

OFFICE

C1-72

OFFICE

C1-71

OFFICE

C1-70A

OFFICE

C1-70

OFFICE

C1-01B

OFFICE

C1-01A

ROI

C1-02

ROI

WAITING

C1-03

OFFICE

C1-03A

C1-01

TLT

C1-74B

CORRIDOR

21-14

C1-08

STORAGE

1-A

STORAGE

1-B

STORAGE

2-A

STORAGE

2-B

OFFICE

C1-12

OFFICE

C1-09

OFFICE

C1-10

OFFICE

C1-11

OFFICE

C1-06

OFFICE

C1-07

TOILET

C1-14

TOILET

C1-15

MY

HEALTH

VET

C1-05

OFFICE

C1-68

OFFICE

C1-67

OFFICE

C1-66

A B C

9.3

10.6

14.6

1W-FCU-3

1W-FCU-1

1W-FCU-5

1W-FCU-4

1W-FCU-6

HAC

C1-62

MEN'S

RESTROOM

C1-63

WOMEN'S

RESTROOM

C1-641W-FCU-2

IT

SERVER

RM

C1-19

IT

SERVER

RM

C1-20

IT

SERVER

RM

C1-21A

IT

SERVER

RM

C1-21

B A

B A

M A

T C

H L

IN

E

M A

T C

H L

IN

E

'LP-3'- 15

AREA OF WORK LIMIT LINE

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:0

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EM101B

FIRST FLOOR MECHANICAL POWER

PLAN - AREA B

15 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

Scale: 1/8" = 1'-0"

FIRST FLOOR MECHANICAL POWER PLAN - AREA B

NORTH

0 4 8 16

A. COORDINATE ELECTRICAL INSTALLATION WITH

CIVIL & STRUCTURAL DRAWINGS INCLUDED AS

PART OF THIS CONSTRUCTION DOCUMENT SET.

B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION

EQUIPMENT DIMENSIONS ARE BY: EATON.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

EQUIPMENT THAT FITS WITHIN THE SIZE

CONSTRAINTS WITH PROPER CLEARANCES.

CONTRACTOR TO FURNISH SHOP DRAWINGS

SHOWING HOW EQUIPMENT PROPOSED WILL FIT

WITHIN THE SPACE CONSTRAINTS ALLOWED

WHILE MAINTAINING PROPER CLEARANCES PER

NEC-110.31, 110.32, AND MANUFACTURER

RECOMMENDATIONS.

C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS

SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C

(UNLESS OTHERWISE NOTED)

D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,

DUCT BANK, AND ELECTRICAL DETAILS FOR

INFORMATION REGARDING POWER FEED

CONSTRUCTION.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

M

M E

S S

S S

SS

S S

S

Q R S T U V

CORRIDOR

C2-26

WAITING

TOILET

STAIR

2E-VAV-1

CLOSET

C2-42A

CARDIAC

REHAB

C2-40

OFFICE

C2-40A

OFFICE

C2-39A

RECREATION

THERAPY

C2-39

MECHANICAL

RM

C2-39B

ELECTRICAL

C2-39C

TOILET

C2-41B

TOILET

C2-41A

OT

CLINIC

OFFICE

C2-42

VESTIBULE

MECH

C2-36

TOILET

C2-38

TOILET

C2-37

OFFICE

C2-35

CONFERENCE

RM

C2-35A

OFFICE

C2-34

TOILET

C2-33A

BARIATRIC

ULTRASOUND

EXAM

C2-33B

TOILET

C2-33C

SOILED

UTILITY

C2-33D

BARIATRIC

ULTRASOUND

EXAM

C2-33E

ULTRASOUND

EXAM

C2-31B

ULTRASOUND

WAITING

C2-29

ULTRASOUND

TECHS/FILES

C2-30

ULTRASOUND

EXAM

C2-31A

CLEAN

HOLDING

C2-31D

TOILET

C2-31C

CORRIDOR

C2-32

CORRIDOR

C2-32A

FILE

RM

OFFICE

OFFICE

OFFICE

STORAGE

OFFICE

OFFICE

STRESS

LAB

BREAK

RM

PRE-TEST

C2-25

CORRIDOR

C2-26

OFFICE

C2-24D

OFFICE

C2-24C

MECH

C2-27A

ELEC

C2-27

TOILET

C2-28

CORRIDOR

'LP-3'- 10

2E-EF-1

'LP-3'- 11

16.6

15.7

14.8

S.4S.1

AREA OF WORK LIMIT LINE

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:1

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EM102A

SECOND FLOOR MECHANICAL POWER

PLAN - AREA A

16 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

SECOND FLOOR MECHANICAL POWER PLAN - AREA A

A. COORDINATE ELECTRICAL INSTALLATION WITH

CIVIL & STRUCTURAL DRAWINGS INCLUDED AS

PART OF THIS CONSTRUCTION DOCUMENT SET.

B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION

EQUIPMENT DIMENSIONS ARE BY: EATON.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

EQUIPMENT THAT FITS WITHIN THE SIZE

CONSTRAINTS WITH PROPER CLEARANCES.

CONTRACTOR TO FURNISH SHOP DRAWINGS

SHOWING HOW EQUIPMENT PROPOSED WILL FIT

WITHIN THE SPACE CONSTRAINTS ALLOWED

WHILE MAINTAINING PROPER CLEARANCES PER

NEC-110.31, 110.32, AND MANUFACTURER

RECOMMENDATIONS.

C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS

SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C

(UNLESS OTHERWISE NOTED)

D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,

DUCT BANK, AND ELECTRICAL DETAILS FOR

INFORMATION REGARDING POWER FEED

CONSTRUCTION.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

E

E

M

M

M

M M

M

M

M

M M

E

M

E

E

M

S SS

S S

S

S SS

S S

S S

D E

TRAINING

ROOM

C2-211

OFFICE

C2-207

HOLDING

C2-205

INTERVIEW

ROOM

C2-206

WOMEN'S

LOCKERS

C2-214

OFFICE

C2-202

ARMORY

C2-210

BREAK

AREA

C2-216

CORRIDOR

C2-200

OFFICE

C2-209

MEN'S TLT

C2-213

MEN'S

LOCKERS

C2-212

WOMEN'S

TLT

C2-215

OFFICE

C2-208

ENTRANCE

C2-204

RECEPTION

C2-203 OFFICE

C2-201

WEAPONS

C2-210A

2W-VAV-9

2W-VAV-2

2W-VAV-4

2W-VAV-1

2W-VAV-3

2W-VAV-7 2W-VAV-8

2W-VAV-6

2W-VAV-52W-VAV-10

2W-EF-1

TOUCHDOWN

A5-005

EXAM

RM

A2-007

EXAM

RM

A2-011

TOILET

A2-009A

TOILET

A2-009

OFFICE

A2-010

STAFF

TOILET

A2-008

WAITING

RM

A2-003

TOILET

A2-05A CHECK-IN

A2-004

CLEAN

LINEN

A2-18

SOILED

A2-017

CORRIDOR

A2-013

A2-002

STAIR

CORRIDOR

C2-11

OFFICE

C2-04

OFFICE

C2-03

MECH

C2-10

ELEC

C2-02

STORAGE

C2-05B

OFFICE

C2-05A

STAIR

2-002

STAIR

CORRIDOR

A2-001

CORRIDOR

C2-32

'W2-E'- 7

'W2-E'- 9

A B CA.2 B.3

9.3

10.6

'SLP2B'- 2

'SLP2A'- 2,4,6

'SLP2A'- 7,9,11

'SLP2B'- 7

'SLP2B'- 5

AHU

ENCLOSURE

C2-211A

2W-AHU-1

2W-VAV-11

AREA OF WORK LIMIT LINE

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:1

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EM102B

SECOND FLOOR MECHANICAL POWER

PLAN - AREA B

17 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

SECOND FLOOR MECHANICAL POWER PLAN - AREA B

A. COORDINATE ELECTRICAL INSTALLATION WITH

CIVIL & STRUCTURAL DRAWINGS INCLUDED AS

PART OF THIS CONSTRUCTION DOCUMENT SET.

B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION

EQUIPMENT DIMENSIONS ARE BY: EATON.

CONTRACTOR IS RESPONSIBLE FOR SELECTING

EQUIPMENT THAT FITS WITHIN THE SIZE

CONSTRAINTS WITH PROPER CLEARANCES.

CONTRACTOR TO FURNISH SHOP DRAWINGS

SHOWING HOW EQUIPMENT PROPOSED WILL FIT

WITHIN THE SPACE CONSTRAINTS ALLOWED

WHILE MAINTAINING PROPER CLEARANCES PER

NEC-110.31, 110.32, AND MANUFACTURER

RECOMMENDATIONS.

C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS

SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C

(UNLESS OTHERWISE NOTED)

D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,

DUCT BANK, AND ELECTRICAL DETAILS FOR

INFORMATION REGARDING POWER FEED

CONSTRUCTION.

E. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

ETR

ETR

VSD VSD VSD VSD VSD

VSD

VSD

VSD VSD VSDVSD

VSD

VSD

V S

D V

S D

LV

LVD

VSD

V S

D

VSD

V S

D V

S D

V S

D

V S

D

VSD VSD VSDVSD

VSD

V S

D

VSD

VSDVSD VSD

V S

OS OS

VS

LVD LVD

VS

VS

VS

LVD

LVD

VSD

VS

VSD

VSD

VSD

VS

OSD

OSOS

OS

OS

VS

VSD

OSDOSDOSD

OSD

OSD

OS

OS

OS

OS

OS

LVD

LVD

VSD

VSD

LVD

LV

D

LV

DLVD

LVD

VS

LVD

OS OS

OS

OS OS OS

OS

OS

OS

OS

OS OS OS

OS

LVD

LVD

LVD

LVD

LVD

SS

N P Q R S T U V

V.9U.4

15.1

16.3

OFFICE/

CONSULT

C1-124

OFFICE/

CONSULT

C1-122

OFFICE/

CONSULT

C1-115

OFFICE/

CONSULT

C1-114

OFFICE/

CONSULT

C1-113

OFFICE/

CONSULT

C1-112

MH

WAITING

C1-100

OFFICE/

CONSULT

C1-153

OFFICE/

CONSULT

C1-152

OFFICE/

CONSULT

C1-150

OFFICE/

CONSULT

C1-151

OFFICE/

CONSULT

C1-130

OFFICE/

CONSULT

C1-131

OFFICE/

CONSULT

C1-135

OFFICE/

CONSULT

C1-136

OFFICE/

CONSULT

C1-137

OFFICE/

CONSULT

C1-138

OFFICE/

CONSULT

C1-139

HAC

C1-158

FAMILY

CONSULT

C1-140

OFFICE/

CONSULT

C1-129

OFFICE/

CONSULT

C1-128

OFFICE/

CONSULT

C1-127

GROUP

THERAPY

C1-126

STAFF

BREAK

ROOM

C1-161

MECHANICAL

C1-116

CORRIDOR

C-102

PATIENT

TOILET

C1-148

PATIENT

TOILET

C1-147

OFFICE/

CONSULT

C1-132

OFFICE/

CONSULT

C1-133

OFFICE/

CONSULT

C1-145

OFFICE/

CONSULT

C1-146

OFFICE/

CONSULT

C1-121

STAFF TLT

C1-107

ELEC

C-101B

TELE-

HEALTH

C1-101

OFFICE/

CONSULT

C1-120

ELECTRICAL

C1-117

OFFICE/

CONSULT

C1-119

ELEC

C1-67

MECH

C1-66

STAIR

STAFF TLT

C1-108

NURSE

WORK

AREA(1)

C-104A

STOR

C1-125

FAMILY

CONSULT

C1-149

NURSE

WORK

AREA

(7

NURSES)

C1-109

NURSE

WORK

AREA

C1-102

RECEPTION

C1-163

MEDS

C1-157

EXAM/

OFFICE/

CONSULT

C1-104

PROCEDURE/

TMS

C1-154

OFFICE/

CONSULT

C1-111

OFFICE/

CONSULT

C1-110

EXAM/

OFFICE/

CONSULT

C1-106

OFFICE/

CONSULT

C1-143

ELEC.

C1-118

OFFICE/

CONSULT

C1-123

EXAM/INJ

NURSE

OFFICE

C1-156

EXAM/

OFFICE/

CONSULT

C1-105

VITALS

C-102B

SUITE

ACCESS

C-103A

TELE-

HEALTH

C1-103

SUITE

ACCESS

C-104

STAFF

LOCKERS

C1-160

FAMILY

CONSULT

C1-134

STOR

C1-141

MSA

C1-162

CORRIDOR

C-106

CORRIDOR

C-105

TR

C1-100A

CORRIDOR

C-101

ELEV

LOBBY

C1-56C

STERILE

SUPPLY

C1-155

OFFICE/

CONSULT

C1-142

OFFICE/

CONSULT

C1-144

O

CORRIDOR

C-107

RCD2

RCD2

MECH

ELEV

ELEV

ELEV

ELEV

ELEV

ELEV

MECHANICAL

C1-22C

MECHANICAL

BASEMENT

ROOF

CRAWL

SPACE

CRAWL

SPACE

BASEMENT

ROOF

BASEMENT

ROOF

ETR

ETR

ETR

ETR

ETR

ETR

A1E A1 A1E

A1

A1E

A1E A1 A1 A1E A1E A1 A1E

D1 D1 D1 D1 D1 D1

A1E

D1

D1 D1

A1

A1E

A1

A1 A1

A1A1

A1

A1

A1

A1E

A1

A1

A1E

A1

A1 A1 A1

A1A1

A1A1

A1A1

A1

A1

A2

A2

A1

A1

A1 A1

A1 A1

A1

A1 A1

A1

A1 A1

A1

A1

A1

A1

A1

A1

A1

A1 A1 A1 A1

A1

A1

A1

A1

A2A2 A2

A1 A1

A1

K1

K1

J1 J1

H1

A1

A1E A1A1A1E

A1

A1

A1

A1

A2

A2

A3

A3

B1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A2

A1

A3F

M1

A1E

A1 A1E A1 A1 A1E A1

A1

A1E

A1 A1 A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1

A1 A1E

A1 A1

A1

C1

C1

C1

C1

A3

A3

A3

A3

A3

A3

A3

A3

A2

A2E

A2

C1

C1

C1

D1

D1

D1

D1

D1

D1

D1

N1

N1N1 N1

N1 N1 D1

D1

D1

E1

E1

E1

E2

E1

E1

E1

E2

E1

E2

E2

E2E2

M1

14.6

A1A1

ETR

CORRIDOR

C-103

M1

RCD2

RCD

RCD

b b b aaa a ba,b a,b

'A'- 2 c c d dc,d dc c,d

RCD2

RCD2 e f g h h g h h g g g,h

RCD

e e e e e e f f f f e,f f f f f f f e,f e,f

B1

H1

A1

CORRIDOR

C-102A

D1

D1

D1

D1D1

STOR.

C1-103B

C1 m l m l m l,m

D1

D1

'LP-3'- 16

'LP-3'- 18

'LP-3'- 20

'LP-3'- 22

'LP-3'- 24

M1

M1

RCD

RCD

'LP-3'- 26

RCD

RCD

'LP-3'- 28

M1 M1M1

B A

B A

M A

T C

H L

IN

E

M A

T C

H L

IN

E

16.6

15.9

15.7

14.8

T.5S.6S.4 V.4V.1S.1

AREA OF WORK LIMIT LINE

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:2

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EL111A

FIRST FLOOR LIGHTING PLAN - AREA A

18 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

Scale: 1/8" = 1'-0"

FIRST FLOOR LIGHTING PLAN - AREA A

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

NORTH

0 4 8 16

A. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS AND LIGHT LEVEL SENSORS ARE

APPROXIMATE. CONTRACTOR SHALL FOLLOW

MANUFACTURER'S RECOMMENDED PLACEMENT

AND INSTALL PER MANUFACTURER'S

INSTRUCTIONS.

B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF

ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

C. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR SENSITIVITY

AND OTHER CONFIGURATIONS WITH THE VA

COR.

D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,

SHOWN ON THIS PLAN, SHALL BE CIRCUITED

FROM LIFE SAFETY EMERGENCY LIGHTING

CIRCUIT 'EELS1A'-2, BUT AHEAD OF ANY

SWITCHING.

E. ALL INTERIOR SWITCHED EMERGENCY

LIGHTING, SHOWN ON THIS PLAN, SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL.

DURING NORMAL NON-EMERGENCY CONDITION

LIGHT FIXTURES SHALL BE SWITCHED WITH

NORMAL LIGHTING AS SHOWN. SEE DETAIL

8/E-501. NORMAL POWER CIRCUIT AS SHOWN

ON PLAN. LIFE SAFETY EMERGENCY POWER

CIRCUIT 'EELS1A'-2.

F. ALL EXTERIOR BUILDING MOUNTED LIGHTING IS

CONTROLLED BY PHOTOCELL AND

ASTRONOMICAL TIME CLOCK.

G. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.

H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT

LIGHTING CONDUCTORS SHALL BE 2-12 AWG,

1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE.

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM

2-10 AWG, 1-10 AWG EG IN 3/4" C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

OS

VSD

OS OS

LVD LVD

OS

OS

LVD

LVD

VSD

OS OS OS OS

OS

OS OS OS OS OS OS

LVDLVD

LVD

LVD

S SS S S

S S

S SS S

S

SS S

S S

S S

S S

S S

S

S

S

S

S

S S

S S

S

S S

S S

S S

S SS S S S S S

S S

S

S

S

S

S S S

S S

S

S

D E F H J L M

GROUP

MEETING

C1-65

ELEVATOR

LOBBY

C1-75

CORRIDOR

C-100

CORRIDOR

C1-69

WOMEN'S

RESTROOM

C1-64

CORRIDOR

C1-18

CORRIDOR

C1-16

CORRIDOR

C1-13

STORAGE

C1-65B

SILVER

ELEV

LOBBY

C1-75

G

CONF

ROOM

A1-10

OFFICE

A1-09

OFFICE

A1-09A

EXAM

A1-08

EXAM

A1-11

EXAM

A1-14

EXAM

A1-16

EXAM

A1-07

EXAM

A1-06

EXAM

A1-20

EXAM

A1-15

EXAM

A1-12

EXAM

A1-23

CLEAN

LINEN

A1-02

T L T

A -2 A

EXAM

A1-27

ELEC

A1-03

ELEC

A1-30

ELEV

S-1

ELEV

S-2

ELEV

S-3

ELEV

P-3

ELEV

P-2

ELEV

P-1

CORR

A1-01

ATRIUM

CORR

A1-04

CORR

A1-13

STAIR

T L T

A -0 A

STAIR

VOLUNTARY

C1-77

STOR

C1-78A

ELEC

C1-76

MECH

C1-78

MECH

ELEV

ELEV

ELEV

ELEV

IT

C1-21B

IT

C1-21C

MECHANICAL

C1-22C

IT

C1-22E

MECH

C1-22G

CRAWL

SPACE

STAIR

ELEV

LOBBY

A1-31A

SOILED

LINEN

A1-29

MECH

C1-04A

ELEC

C1-04

ELEC

C1-17A

ELEC

C1-17

A1-05

A1-28

CORR

A1-22A

HAC

A1-26

A1-22B

21-3

21-4

OFFICE

C1-74

OFFICE

C1-74A

OFFICE

C1-73

OFFICE

C1-72

OFFICE

C1-71

OFFICE

C1-70A

OFFICE

C1-70

OFFICE

C1-01B

OFFICE

C1-01A

ROI

C1-02

ROI

WAITING

C1-03

OFFICE

C1-03A

C1-01

TLT

C1-74B

CORRIDOR

21-14

C1-08

STORAGE

1-A

STORAGE

1-B

STORAGE

2-A

STORAGE

2-B

OFFICE

C1-12

OFFICE

C1-09

OFFICE

C1-10

OFFICE

C1-11

OFFICE

C1-06

OFFICE

C1-07

TOILET

C1-14

TOILET

C1-15

MY

HEALTH

VET

C1-05

OFFICE

C1-68

OFFICE

C1-67

OFFICE

C1-66

RCD2

A1 A1E A1 A1 A1E A1 D1 D1

A1 A1E A1

A1

A1E

A1 A1E A1 A1 A1E A1

A1

A1E

H1

H1

H1 H1 H1

B1

B1E B1E

B1 B1

B1

D1

D1

D1

A2

N1

N1

D1

D1

D1

D1 D1

D1

D1

E1

E2

E1

A1

A1E

A1

E2

A B C

ETR

ETR

ETR

ETR

ETR

e e e,f j j k k kk kj kj

RCD

RCD

B1

B1

B1 j,k j j

MEN'S

RESTROOM

C1-63

HAC

C1-62

A1

3 3

RCD

IT

SERVER

RM

C1-19

IT

SERVER

RM

C1-20

IT

SERVER

RM

C1-21A

IT

SERVER

RM

C1-21

B A

B A

M A

T C

H L

IN

E

M A

T C

H L

IN

E

AREA OF WORK LIMIT LINE

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:3

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EL111B

FIRST FLOOR LIGHTING PLAN - AREA B

19 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

Scale: 1/8" = 1'-0"

FIRST FLOOR LIGHTING PLAN - AREA B

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

NORTH

0 4 8 16

A. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS AND LIGHT LEVEL SENSORS ARE

APPROXIMATE. CONTRACTOR SHALL FOLLOW

MANUFACTURER'S RECOMMENDED PLACEMENT

AND INSTALL PER MANUFACTURER'S

INSTRUCTIONS.

B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF

ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

C. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR SENSITIVITY

AND OTHER CONFIGURATIONS WITH THE VA

COR.

D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,

SHOWN ON THIS SHEET, SHALL BE CIRCUITED

FROM NEAREST LIFE SAFETY EMERGENCY

LIGHTING CIRCUIT AS INDICATED ON PLAN, BUT

AHEAD OF ANY SWITCHING.

E. ALL INTERIOR SWITCHED EMERGENCY

LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL.

DURING NORMAL NON-EMERGENCY CONDITION

LIGHT FIXTURES SHALL BE SWITCHED WITH

NORMAL LIGHTING AS SHOWN. SEE DETAIL

8/E-501. NORMAL POWER AND LIFE SAFETY

EMERGENCY POWER CIRCUIT AS INDICATED ON

PLAN.

F. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.

G. ALL 120 VOLT 20 AMP BRANCH CIRCUIT

LIGHTING CONDUCTORS SHALL BE 2-12 AWG,

1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE.

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM

2-10 AWG, 1-10 AWG EG IN 3/4" C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

1 CONNECT TO EXISTING NORMAL LIGHTING

CIRCUIT SERVING THIS SAME AREA, RETAINED

DURING DEMOLITION.

2 CONNECT TO EXISTING CORRIDOR NORMAL

LIGHTING CIRCUIT SERVING THIS SAME AREA,

RETAINED DURING DEMOLITION.

3 CONNECT TO EXISTING CORRIDOR LIFE SAFETY

LIGHTING CIRCUIT, RETAINED DURING

DEMOLITION.

4 CONNECT TO EXISTING LIFE SAFETY LIGHTING

CIRCUIT SERVING THIS SAME AREA, RETAINED

DURING DEMOLITION.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

OS

OS

LVD

LVD

S S

S S

SS

S S

S

R S T

OFFICE

C2-40A

OFFICE

C2-39A

RECREATION

THERAPY

C2-39

MECHANICAL

RM

C2-39B

ELECTRICAL

C2-39C

VESTIBULE

MECH

C2-36

TOILET

C2-38

TOILET

C2-37

OFFICE

C2-35

CONFERENCE

RM

C2-35A

OFFICE

C2-34

TOILET

C2-33A

BARIATRIC

ULTRASOUND

EXAM

C2-33B

SOILED

UTILITY

C2-33D

ULTRASOUND

WAITING

C2-29

ULTRASOUND

TECHS/FILES

C2-30

CLEAN

HOLDING

C2-31D

CORRIDOR

C2-32A

FILE

RM

OFFICE

OFFICE

OFFICE

CORRIDOR

C2-26

MECH

C2-27A

ELEC

C2-27

TOILET

C2-28

CORRIDOR

WAITING

TOILET

STAIR

CORRIDOR

C2-26

A1A1

B1

H1

W1E

A2E

A2

A2E

E1

E1

A1E

STAIR EXIT

CORRIDOR

2C

RCD

RCD

A2

16.6

15.7

14.8

S.4S.1

STOR

CG-18C

LOCKER

CG-22

STORAGE

CG-23

STORAGE

CG-25

STORAGE

CG-26

BREAK

RM

CG-28

WASTE

MANAGEMENT

EG-45

CART

WASH

FG-43

REFR

CG-53

REFR

CG-52

MECHANICAL

RM

CG-51A

WM

CG-51

CORRIDOR

CG-49

MECH

CG-20A

REPRODUCTION

OFFICE

CG-59

REPRODUCTION

OFFICE

CG-58

EMS

STORAGE

CG-57

BREAL

RM

CG-56

TOILET

CG-21

CORRIDOR

CG-61A

STORAGE

RM

CG-64

CORRIDOR

CG-54

CORRIDOR

LD-2

ELEC

CG-20

STAIR

CG-20B

STORAGE RM

ELEC

STOR

CG-18A

CG-61C

CG-55

LD-1

S T U V

W1E W1E W1E

'LP-3'- 32

W1E

'EELS1A'- 4

10'-0"

AFF

10'-0"

AFF

E1

AREA OF WORK LIMIT LINE

P1E

P1E

P1E

'EELS1A'- 4

Engineers Architects

# KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:4

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EL112A

SECOND, GROUND FLOOR AND SITE

LIGHTING PLANS - AREA A

20 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

SECOND FLOOR LIGHTING PLAN - AREA A

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

A. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS AND LIGHT LEVEL SENSORS ARE

APPROXIMATE. CONTRACTOR SHALL FOLLOW

MANUFACTURER'S RECOMMENDED PLACEMENT

AND INSTALL PER MANUFACTURER'S

INSTRUCTIONS.

B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF

ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

C. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR SENSITIVITY

AND OTHER CONFIGURATIONS WITH THE VA

COR.

D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,

SHOWN ON THIS SHEET, SHALL BE CIRCUITED

FROM NEAREST LIFE SAFETY EMERGENCY

LIGHTING CIRCUIT AS INDICATED ON PLAN, BUT

AHEAD OF ANY SWITCHING.

E. ALL INTERIOR SWITCHED EMERGENCY

LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL.

DURING NORMAL NON-EMERGENCY CONDITION

LIGHT FIXTURES SHALL BE SWITCHED WITH

NORMAL LIGHTING AS SHOWN. SEE DETAIL

8/E-501. NORMAL POWER AND LIFE SAFETY

EMERGENCY POWER CIRCUITS AS INDICATED

ON PLAN.

F. ALL EXTERIOR BUILDING MOUNTED LIGHTING IS

CONTROLLED BY PHOTOCELL AND

ASTRONOMICAL TIME CLOCK.

G. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.

H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT

LIGHTING CONDUCTORS SHALL BE 2-12 AWG,

1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE.

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM

2-10 AWG, 1-10 AWG EG IN 3/4" C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

Scale: 1/8" = 1'-0"

GROUND FLOOR LIGHTING PLAN - AREA A

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

GROUND

FLOOR

AREA OF

WORK

GROUND FLOOR

SECOND FLOOR

1 CONNECT TO EXISTING STAIR 2 LIFE SAFETY

LIGHTING CIRCUIT AND CONTROLS.

2 CONNECT TO EXISTING NORMAL LIGHTING

CIRCUIT SERVING THIS SAME AREA, RETAINED

DURING DEMOLITION.

3 CONNECT TO NEAREST EXISTING CORRIDOR LIFE

SAFETY LIGHTING CIRCUIT, RETAINED DURING

DEMOLITION.

LEGEND

NORTH

0 105 20

Scale: 1" = 10'-0"

ELECTRICAL SITE LIGHTING PLAN

NORTH

0 4 8 16

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

LVD LVD LVD

VS

VS

VSD

VSD

VSD

VSD

VSD

OSD

VSD

OS

OSD VSD

VSD VSD

VSD

LVD

OS OS

OS

LVD

S SS

S S

S

S SS

S S

S S

D E

TRAINING

ROOM

C2-211

OFFICE

C2-207

HOLDING

C2-205

INTERVIEW

ROOM

C2-206

WOMEN'S

LOCKERS

C2-214

OFFICE

C2-202

ARMORY

C2-210

BREAK

AREA

C2-216

CORRIDOR

C2-200

OFFICE

C2-209

MEN'S TLT

C2-213

MEN'S

LOCKERS

C2-212

WOMEN'S

TLT

C2-215

OFFICE

C2-208

ENTRANCE

C2-204

RECEPTION

C2-203

OFFICE

C2-201

TOUCHDOWN

A5-005

EXAM

RM

A2-007

EXAM

RM

A2-011

TOILET

A2-009A

TOILET

A2-009

OFFICE

A2-010

STAFF

TOILET

A2-008

WAITING

RM

A2-003

TOILET

A2-05A CHECK-IN

A2-004

CLEAN

LINEN

A2-18

SOILED

A2-017

A2-002

STAIR

CORRIDOR

C2-11

OFFICE

C2-04

OFFICE

C2-03

MECH

C2-10

ELEC

C2-02

STORAGE

C2-05B

OFFICE

C2-05A

STAIR

2-002

STAIR

CORRIDOR

A2-001

CORRIDOR

C2-32

RCD2

RCD

A2

A1

C1

B1

A2E

A1

A1

A1E

A2E

A2 A2

B1

B1B1

A1

A1

A1

A1

A1

A1

A1 C1 C1

C1

C1

L1 L1

A1E

A2

A2

A1 A1

A1A1

B1 B1

B1B1

F1 F1

L1E

H1

H1

M1

E1

E2

E1

E1

C1

C1

C1

C1

C1C1

C1

C1

C1

F1

A B CA.2 B.3

9.3

10.6

WEAPONS

C2-210A

M1

C1

'SLP2B'- 3

RCD

RCD

a a b b a b a,b a,b

'W2-E'- 11

'W2-E'- 13

AHU

ENCLOSURE

C2-211A

C1

AREA OF WORK LIMIT LINE

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

SHEET NOTES:

WALL RATING LEGEND

1 HR - SMOKE BARRIER

2 HR - FIRE BARRIER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

S S S S

S S

S S

SMOKE RESISTIVE HAZARDOUS AREA

1 HR - FIRE BARRIER

2 HR - SMOKE BARRIER

/1

/2

:0

:4

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

EL112B

SECOND FLOOR LIGHTING PLAN -

AREA B

21 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

NORTH

0 4 8 16

Scale: 1/8" = 1'-0"

SECOND FLOOR LIGHTING PLAN - AREA B

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

A

B

A

B

A. LOCATION AND QUANTITY OF OCCUPANCY

SENSORS AND LIGHT LEVEL SENSORS ARE

APPROXIMATE. CONTRACTOR SHALL FOLLOW

MANUFACTURER'S RECOMMENDED PLACEMENT

AND INSTALL PER MANUFACTURER'S

INSTRUCTIONS.

B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF

ALL LIGHTING CONTROLS WITH THE LED

DRIVERS TO BE CONTROLLED.

C. COORDINATE ALL TIME DELAY, AUTO DIM,

PRESET DIMMING LEVELS, SENSOR SENSITIVITY

AND OTHER CONFIGURATIONS WITH THE VA

COR.

D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,

SHOWN ON THIS SHEET, SHALL BE CIRCUITED

FROM LIFE SAFETY EMERGENCY LIGHTING

CIRCUIT 'W2-EL'-9, BUT AHEAD OF ANY

SWITCHING.

E. ALL INTERIOR SWITCHED EMERGENCY

LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE

BOTH NORMAL AND EMERGENCY POWER.

DURING EMERGENCY CONDITION THE

GENERATOR TRANSFER DEVICE SHALL DETECT

NORMAL POWER VOLTAGE LOSS, TRANSFER TO

EMERGENCY POWER AND RETURN TO FULL-

OUTPUT UPON LOSS OF CONTROL SIGNAL.

DURING NORMAL NON-EMERGENCY CONDITION

LIGHT FIXTURES SHALL BE SWITCHED WITH

NORMAL LIGHTING AS SHOWN. SEE DETAIL

8/E-501. NORMAL POWER CIRCUIT AS SHOWN

ON PLAN. LIFE SAFETY EMERGENCY POWER

CIRCUIT 'W2-EL'-9.

F. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.

G. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.

H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT

LIGHTING CONDUCTORS SHALL BE 2-12 AWG,

1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED

OTHERWISE.

a. RUNS LESS THAN 150' SHALL BE MINIMUM

2-12 AWG, 1-12 AWG EG IN 3/4" C.

b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM

2-10 AWG, 1-10 AWG EG IN 3/4" C.

c. RUNS GREATER THAN 250' SHALL BE

MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.

LEGEND

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

BOND TO INTERIOR METAL

COLD WATER PIPING

GROUNDING ELECTRODE CONDUCTOR

GROUNDING BAR-BOND TO ENCLOSURE

COMMUNICATION GROUND

BAR. SEE TELECOM

BOND TO STRUCTURAL STEEL (MIN. 1/2"

BAR) IN FOOTING-CONDUCTOR SHALL

BE CONTINUOUS FROM GROUND BAR

TO GROUND ROD

GROUNDING ELECTRODE CONDUCTOR

BOND TO 3-3/4" X 10'

COPPERCLAD STEEL

DRIVEN GROUND

RODS - SPACE 10'

APART

EQUILATERALLY

NOTES:

1. GROUNDING CONDUCTORS AND

MAIN BONDING JUMPER SHALL BE

BARE COPPER UNO AND SHALL BE

SIZED AS INDICATED ON SINGLE LINE.

2. ALL AVAILABLE GROUND

ELECTRODES SHALL BE USED.

LIGHTNING PROTECTION

GROUNDING SHALL ALSO BE

BONDED TO THE GROUNDING

ELECTRODE SYSTEM.

SERVICE

EQUIPMENT

N

G B

TMGB

3/4" PVC CONDUIT - TYPICAL FOR GROUNDING

ELECTRODE CONDUCTOR CONDUIT

NEUTRAL (GROUNDED

CONDUCTOR) BAR

MAIN BONDING JUMPER

SIZE PER SINGLE-LINE

BOND EQUIPMENT

GROUNDING CONDUCTOR

TO SERVICE RACEWAY(S)

BOND TO METAL

UNDERGROUND WATER

PIPE ON SUPPLY SIDE OF

MAIN COLD WATER VALVE

1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE

BLOCKS*. MAX DIAM OF CIRCULAR THROUGH OPENING IS 32-1/2 IN. (826 MM).

SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF

MANUFACTURERS.

1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE SLEEVE CAST INTO CONCRETE FLOOR OR WALL. SLEEVE TO BE FLUSH WITH OR PROJECT MAX 2 IN. (51MM) FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL.

2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM)(POINT CONTACT) TO MAX 1-3/8 IN. (35 MM).

PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING

TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:

A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.

A1. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.

B. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.

C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.

3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC (ALUMINA SILICA) FIBER BLANKET, MINERAL WOOL BATT OR GLASS FIBER INSULATION MATERIAL USED AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF SOLID CONCRETE OR CONCRETE BLOCK WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4). AS AN ALTERNATE WHEN MAX PIPE SIZE IS 10 IN. (254 MM) DIAM AND WHEN MAX ANNULAR SPACE IS 1 IN. (25 MM), A MIN 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC FIBER BLANKET OR MINERAL WOOL BATT PACKING MATERIAL MAY BE RECESSED MIN 1/2 IN. (13 MM) FROM BOTTOM SURFACE OF FLOOR OR FROM EITHER SIDE OF SOLID CONCRETE WALL.

4. FILL,VOID OR CAVITY MATERIALS* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE TO THE

MIN THICKNESS SHOWN IN THE FOLLOWING TABLE:

(A) BR = POLYETHYLENE BACKER ROD.

CF = CERAMIC FIBER BLANKET.

GF = GLASS FIBER INSULATION.

MW = MINERAL-WOOL BATT.

(B) CAULK INSTALLED FLUSH WITH TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL.

(C) CAULK INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR OR ONE SURFACE OF SOLID (NON-

CONCRETE BLOCK) WALL.

3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT.

(NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)

*BEARING THE UL CLASSIFICATION MARKING

MAX PIPE DIAM

IN. (MM)

10 (254)

10 (254)

30 (762)

MAX ANNULAR

SPACE IN. (MM)

1 (25)

1 (25)

2-1/2 (64)

PACKING MATL

TYPE (a)

BR, CF, GF OR MW

CF OR MW

BR, CF, GF OR MW

MIN. CAULK THKNS

IN. (MM)

1/2 (13) (b)

1/2 (13) (c)

1 (25) (b)

System No. C-AJ-1001 June 15, 2005 F Rating - 3 Hr T Rating - 0 Hr

W Rating - Class I (See Item 4)

SECTION A-A

4 4 1

A

A

3/8" MAX[10mm]

MINERAL WOOL

(FIRMLY

PACKED)

CONDUIT, TYP

FLOOR

SLAB,

TYP.

FIRE STOP SEALANT

INTEGRAL

GALVANIZED LIPPED

STEAL MOUNTING

CHANNEL, TYP.

STEEL

EXPANSION

ANCHOR, TYP.

SPRING NUT,

TYP

CONDUIT COMPRESSION

FITTING, TYP.

JUNCTION BOX

(SIZE AS

REQUIRED)

SPRING NUT

CONDUIT FITTING

JUNCTION BOX

(SIZE AS

REQUIRED)

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

JUNCTION BOX, TYP

(SIZE AS REQUIRED)

BEAM

CLAMP,

TYP.

CONDUIT

TRAPEZE PER

SD260533-03, TYP. CONDUIT,

TYP.

STEEL

EXPANSION

ANCHOR

STRUCTURAL MEMBER

(BEAM , JOIST, ETC.), TYP.

SEISMIC OR

EXPANSION

JOINT. FIELD

VERIFY

ACTUAL

CONDITIONS &

LOCATIONS.

FLOOR OR ROOF

STRUCTURE. FIELD VERIFY

ACTUAL CONDITIONS, TYP.

PROVIDE 127MM (5") OF SLACK AT

MIDPOINT BETWEEN TWO END OF

FLEXIBLE GALVANIZED STEEL CONDUIT.

PROVIDE GREEN INSULATED COPPER

EQUIPMENT GROUNDING CONDUCTOR

WITH FLEXIBLE CONDUIT.

914mm

(3'-0") MAX

PROVIDE EXTRA CABLE TO

MAKE COMPLETE LOOP

AROUND BOX PERIMETER

GENERAL NOTE:

1. DETAIL IS APPLICABLE

ONLY FOR CONDUITS

SMALLER THAN 76MM (3").

STEP 1. FILE STRUCTURE CONNECTION AREA (3 IN. X 3. IN.

MIN) TO BARE SHINY METAL AND CLEAN.

GENERAL NOTES:

A. ALL CABLES AND WELDS SHALL BE MINIMUM 3 INCHES APART.

B. STANDARD WELD CARTRIDGES SHALL BE USED FOR STEEL SURFACES.

FOR DIP USE XF-19 WELD CARTRIDGES.

STEP 2. STRIP INSULATION FROM WIRE. ATTACH SLEEVE

(REQUIRED ON NO.4 AWG WIRE AND SMALLER).

STEP 3. HOLD MOLD FIRMLY WITH OPENING AWAY FROM

OPERATOR AND IGNITE WITH FLINT GUN.

STEP 4. REMOVE SLAG FROM CONNECTION AND PEEN

WELD FOR SOUNDNESS.

STEP 5. COVER CONNECTION AND EXPOSED STRUCTURE

SURFACE WITH AN EPOXY COATING.

HANDLE GRAPHITE COVER

STARTING POWDER

METAL WELDING POWDER

GRAPHITE MOLD

WIRE

PIPE WALL

METAL DISC

30° MAX.

FINISHED GRADE

GROUND ROD SHALL NOT BE ANGLED

MORE THAN 30° FROM VERTICAL.

ANGLE AWAY FROM SHELTER OR PAD

WHERE POSSIBLE.

3/4" DIAMETER COPPER CLAD

STEEL GROUND ROD 10' LONG.

AT LEAST 8' OF GROUND ROD IN

CONTACT WITH SOIL

GEC

ECLEUL

NO SLAG OR

DEFORMITIES

ALLOWED

EXOTHERMIC WELD

(THERMOWELD OR

EQUIVALENT). PARALLEL,

NO T-WELDS ALLOWED.

EXTERIOR GROUND RING,

2 AWG SOLID, BARE,

TINNED COPPER

GROUNDING CONDUCTOR

MINIMUM BENDING RADIUS

45 DEGREES, TYPICAL

JUMPER, 2 AWG SOLID,

BARE, TINNED COPPER

GROUNDING CONDUCTOR

BROWN

RED

BLUE

EMERGENCY

PANEL

WALL

SWITCH

GTD

BLACK 120V

OR ORANGE

277V (CAP

UNUSED LEAD)

VOLTAGE

SENSING

AC

BALLAST

OR

DRIVER

LAMP LEADS

NOT SHOWN

BLACK

WHITE

WHITE

WHITE/RED

WHITE/BLACK

NORMAL

PANEL

NORMAL

POWER

GENERATOR

ATS

G

NEUTRAL BUS

FOR NORMAL

PANEL

NEUTRAL BUS

FOR EMERGENCY

PANEL

AIR TERMINAL

GENERAL NOTES:

A. SEE PLATE E-001 FOR LEGEND.

B. ALL SPLICES BELOW GRADE SHALL BE THE EXOTHERMIC

WELD TYPE.

C. AIR TERMINALS SHALL EXTEND NO LESS THAN 24 INCHES

ABOVE THE ROOF.

D. ALL METAL EQUIPMENT ON THE ROOF SHALL BE BONDED

TO THE LIGHTNING PROTECTION SYSTEM.

E. THRU ROOF FLASHING SHALL BE COPPER WITH 8 INCH

ROUND BASE AND VERTICAL TUBE WITH NEOPRENE SEAL.

FLASHING SHALL BE THE PRODUCT OF THE

MANUFACTURER OF THE LIGHTNING PROTECTION SYSTEM.

A MEMBRANE FLASHING SHALL BE PROVIDED OVER THE

THRU ROOF FLASHING.

MAIN CONDUCTOR

CLIP CABLE SUPPORT

SEALING WASHER

(M

IN

RIGID STEEL CONDUIT

PVC CONDUIT

PVC CONDUIT

ADAPTER

COUPLING

FINISHED GRADE

VANDAL RESISTANT LIGHT

BOLLARD PER LIGHT

FIXTURE SCHEDULE

GALVANIZED ANCHOR BOLTS &

HEX NUTS. PROVIDE LEVELING

SHIMS OR HEX NUTS.

CONCRETE BASE &

REINFORCING

STEEL SEE NOTE

BELOW.

UNDISTURBED SOIL

OR SELECT BACKFILL

COMPACTED, SEE

NOTE BELOW.

GENERAL NOTES:

1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE

SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON

STRUCTURAL DRAWINGS.

2. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND

LEVELING REQUIREMENTS.

[7 M

M

M

IN

[6 M

M

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:0

:3

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

E-501

ELECTRICAL DETAILS

22 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

Scale: No Scale

SERVICE GROUNDING DETAIL

Scale: No Scale

UL PENETRATION DETAIL C-AJ-1001

Scale: No Scale

FLOOR SLAB PENETRATION DETAIL

Scale: No Scale

CONDUIT EXPANSION JOINT CROSSING - FLEXIBLE

CONDUIT

Scale: No Scale

EXOTHERMIC WELD - WIRE TO PIPE

Scale: No Scale

GROUND ROD DETAIL

Scale: No Scale

GROUNDING MECHANICAL

BOND

Scale: No Scale

EXOTHERMIC WELD - WIRE TO WIRE

Scale: No Scale

EMERGENCY LIGHTING CONTROL (GENERATOR TRANSFER

DEVICE)

Scale: No Scale

LIGHTNING PROTECTION AIR TERMINAL

1 1

Scale: No Scale

BOLLARD BASE DETAIL

DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C

EXISTING PANEL

'EECR1B'

120/208V, 3PH, 4W

100A MCB

ELEC C1-117

FROM EXISTING

PANEL 'EECR1A'

480/277V, 3PH, 4W

125A MLO

EXISTING 30

KVA

480-208Y/120V, 3PH DRY TYPE

TRANSFORMER

'EECR1B'

EXISTING PANEL

'EELS1'

120/208V, 3PH, 4W

125A MLO

ELEC C1-117

FROM EXISTING

LIFE SAFETY

BRANCH

NEW PANEL 'LP-1'

120/208V, 3PH, 4W

200A MCB

ELEC C1-118

NEW PANEL 'LP-2'

120/208V, 3PH, 4W

100A MCB

ELEC C1-118

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

4-4/0 AWG,

1-4 AWG EG,

IN 2 1/2" C.

NEW PANEL 'A'

120/208V, 3PH, 4W

100A MCB

TR C1-100A

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

NEW PANEL 'B'

120/208V, 3PH, 4W

100A MCB

TR C1-100A

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

NEW PANEL 'LP-3'

120/208V, 3PH, 4W

100A MCB

ELEC C1-118SUPPLEMENTAL

GROUND, BONDED TO

NEW ADDITION STEEL

AND NEW DRIVEN

GROUND ROD

4 AWG GEC

NEW PANEL

'EELS1A'

120/208V, 3PH, 4W

100A MCB

ELEC C1-118

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

NEW 15 KVA

480-208Y/120V, 3PH DRY TYPE

TRANSFORMER

'EELS1T'

WALL MOUNTED

ELEC C1-118

4-10 AWG,

1-10 AWG EG,

IN 3/4" C.

EXISTING PANEL 'MP-1'

208/120V, 3PH, 4W 1000A

SQUARE D I-LINE TYPE HCR-U

BASEMENT ROOF

MECHANICAL ROOM

100A

200AF

200AT

200A

100A100A100A 100A

100A 100A

NORMAL BRANCH CRITICAL BRANCH

100A

100A

100A

30A

LIFE SAFETY BRANCH

PROVIDE NEW BREAKER

IN EXISTING PANEL

FROM EXISTING

EXISTING PANEL

'SLP2'

277/480V, 3PH, 4W

125A MLO

SQUARE D NQOD

ELECTRICAL

A2-119

NEW PANEL

'SLP2A'

277/480V, 3PH, 4W

100A MCB

SECOND FLOOR

MECHANICAL

ROOF

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

NEW 30 KVA

480-208Y/120V, 3PH

DRY TYPE

TRANSFORMER

'SLP2T'

SECOND FLOOR

MECHANICAL ROOF

NEW PANEL 'SLP2B'

120/208V, 3PH, 4W

100A MCB

SECOND FLOOR

MECHANICAL ROOF

4-3 AWG,

1-8 AWG EG,

IN 1 1/4" C.

4-8 AWG,

1-10 AWG EG,

IN 3/4" C.

100A

100A

50A

100A

CRITICAL BRANCH

Engineers Architects

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/1

/2

:0

:3

P

M C

U s e rs

\a m a s o n

\D o c u m e n ts \E

-0

-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g

-p a .c o m

.r v t

E-601

ELECTRICAL SCHEDULES AND SINGLE

LINE DIAGRAMS

23 26KLC

EXPAND MENTAL HEALTH

CLINIC

WILKES-BARRE VA MEDICAL CENTER

1111 EAST END BLVD

WILKES-BARRE, PA 18711 FEBRUARY 21, 2024

100% CONSTRUCTION DOCUMENTS

693-35220-083

JKM

GENERAL NOTES:

A. MANUFACTURER AND CATALOG NUMBERS SHOWN ARE FOR BASIS OF DESIGN, DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION AND APPROVAL. CONTRACTOR TO PROVIDE PRODUCT OR EQUAL FOR APPROVAL BY OWNER, ARCHITECT AND ENGINEER. ENGINEER SHALL NOT BE RESPONSIBLE FOR MISMATCHED OR INACCURATE PART NUMBERS.

B. FOR ALL LED FIXTURES, THE FIXTURE SHALL BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, SHALL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY. PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.

C. LIGHTING CONTROLS, INCLUDING CONTROL SCHEMATICS, DEVICES, SWITCHES, SENSORS AND GRAPHIC DISPLAYS/CONTROLLERS. THIS INFORMATION MUST BE SUBMITTED WITH THE LIGHT FIXTURE SHOP DRAWINGS, FOR

A COMPLETE REVIEW.

LUMINAIRE SCHEDULE

TYPE DESCRIPTION MOUNTING LAMP DRIVER VOLTAGE WATTS MANUFACTURER MODEL NUMBER

A1 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER

RECESSED

GRID

LED; 4,000 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 31 W LITHONIA 2BLT4 40L ADSM EZ1 LP835

A1E 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER; WITH GENERATOR TRANSFER DEVICE

RECESSED

GRID

LED; 4,000 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 31 W LITHONIA 2BLT4 40L ADSM EZ1 LP835 BGTD

A2 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER

RECESSED

GRID

LED; 6,000 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 48 W LITHONIA 2BLT4 60L ADSM EZ1 LP835

A2E 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER WITH GENERATOR TRANSFER DEVICE

RECESSED

GRID

LED; 6,000 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 48 W LITHONIA 2BLT4 60L ADSM EZ1 LP835 BGTD

A3 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER

RECESSED

GRID

LED; 7,300 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 59 W LITHONIA 2BLT4 72L ADSM EZ1 LP835

A3F 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER

RECESSED

FLANGE

LED; 7,300 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% DRIVER

MULTI-VOLT 59 W LITHONIA 2BLT4 72L ADSM EZ1 LP835

B1 2' X 2' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER

RECESSED

GRID

LED; 3,330 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% LED

DRIVER

MULTI-VOLT 27 W LITHONIA 2BLT2 33L ADSM EZ1 LP835

B1E 2' X 2' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER

DIFFUSER WITH GENERATOR TRANSFER DEVICE

RECESSED

GRID

LED; 3,330 LUMENS;

80 CRI; 3500K

0-10V DIMMABLE

TO 1% LED

DRIVER

MULTI-VOLT 27 W LITHONIA 2BLT2 33L ADSM EZ1 LP835 BGTD

C1 4' LINEAR LED STRIPLIGHT WITH FROSTED LENS CHAIN

SUSPEND

LED; 4,585 LUMENS;

80 CRI; 4000K

ELECTRONIC LED

DRIVER

MULTI-VOLT 34 W LITHONIA ZL1N L48 5000LM FST MVOLT 40K 80CRI

D1 6" DIAMETER DIMMABLE LED WIDE DISTRIBUTION DOWNLIGHT RECESSED

FLANGE OR

GRID

LED; 2,000 LUMENS;

3500K; 80 CRI

0-10V DIMMABLE

TO 10% LED

DRIVER

MULTI-VOLT 20 W GOTHAM EVO6 35/20 AR MWD LD MVOLT GZ10

E1 CONTEMPORARY LED SINGLE FACED EXIT SIGN WITH BLACK

POWDER PAINT ALUMINUM HOUSING, BRUSHED ALUMINUM FACE,

RED LETTERS, AND CHEVRON ARROWS AS SHOWN ON PLANS.

UNIVERSAL LED RED --- MULTI-VOLT 5 W LITHONIA LES 1 R 120/277

E2 CONTEMPORARY LED DOUBLE FACED EXIT SIGN WITH BLACK

POWDER PAINT ALUMINUM HOUSING, BRUSHED ALUMINUM FACE,

RED LETTERS, AND CHEVRON ARROWS AS SHOWN ON PLANS.

UNIVERSAL LED RED --- MULTI-VOLT 5 W LITHONIA LES 2 R 120/277

F1 6" DIAMETER DIMMABLE LED WET LOCATION SHOWER DOWNLIGHT RECESSED LED; 1,000 LUMENS;

3500K; 80 CRI

0-10V DIMMABLE

LED DRIVER

MULTI-VOLT 20 W GOTHAM EVO6SH 35/10 DFF SMO MVOLT EZ10

H1 25.5" VANITY; CURVED WHITE ACRYLIC DIFFUSER; NICKEL TONE

FINISH

SURFACE

WALL

LED; 1,500 LUMENS;

80 CRI; 3500K

ELECTRONIC LED

DRIVER

MULTI-VOLT 16 W BROWNLEE 5190-26-NT-H16-35K-BAC

J1 29" BULL NOSE VANITY; TWO APERTURES FOR UP/DOWN LIGHT;

BEHAVIORAL HEALTH RATED

SURFACE

WALL

LED; 4,500 LUMENS;

80 CRI; 3500K

ELECTRONIC LED

DRIVER

MULTI-VOLT 57 W KENALL WCBU 2 0/0 25L35K DIM1 DV SYM/G 1

K1 6" DIAMETER DIMMABLE LED MEDIUM DISTRIBUTION DOWNLIGHT;

CLEAR POLYCARBONATE LENS; BEHAVIORAL HEALTH RATED

RECESSED

FLANGE OR

GRID

LED; 850 LUMENS;

3500K; 80 CRI

0-10V DIMMABLE

TO 1% LED

DRIVER

MULTI-VOLT…