Attachment 5- Drawings - EMHC - Part 4 of 4.pdf
PDF 9 MB Posted
- Solicitation number
- 36C77624R0079_1
About this file
This document appears to be a set of drawings and specifications related to the "Expand Mental Health Clinic" construction project at the Wilkes-Barre VA Medical Center in Wilkes-Barre, Pennsylvania. The project is a competitive Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, solicitation number 36C77624R0079_1. The contractor will be required to provide all labor, project management, materials, tools, supplies, and equipment to complete the necessary work. The drawings cover mechanical, electrical, and lighting plans for the first and second floors, as well as electrical schedules and details. The project is for the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
R
J J J
J
J
48"
GFI
GFI
G
FI
GFI
GFI
48"
GFI
48"
GFI
AC
AC
48"
GFI
GFI
GFI
GFI
GFI
GFI
J
J
J
J
J
J
J
J
J
J
J
S SS
S S
S S
S SS
S S
S S
D E
TRAINING
ROOM
C2-211
OFFICE
C2-207
HOLDING
C2-205
INTERVIEW
ROOM
C2-206
WOMEN'S
LOCKERS
C2-214
OFFICE
C2-202
ARMORY
C2-210
BREAK
AREA
C2-216
CORRIDOR
C2-200
OFFICE
C2-209
MEN'S TLT
C2-213
MEN'S
LOCKERS
C2-212
WOMEN'S
TLT
C2-215
OFFICE
C2-208
ENTRANCE
C2-204
RECEPTION
C2-203
OFFICE
C2-201
WEAPONS
C2-210A
TOUCHDOWN
A5-005
EXAM
RM
A2-007
EXAM
RM
A2-011
TOILET
A2-009A
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A CHECK-IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
CORRIDOR
A2-013
A2-002
ELECTRICAL
A2-119
ELEV
S-1
ELEV
S-2
ELEV
S-3
LOCKER
RM
C2-115
STAIR
CORRIDOR
C2-11
OFFICE
C2-04
OFFICE
C2-03
MECH
C2-10
ELEC
C2-02
C2-09
STORAGE
C2-05B
OFFICE
C2-05A
TOILET
2-130
STAIR
2-002
STAIR
CORRIDOR
A2-001
CORRIDOR
C2-32
A B CA.2 B.3
9.3
10.6
EXISTING
PANEL 'W2-E'
EXISTING
PANEL 'W2P'
EXISTING
PANEL 'SLP2'
'SLP2B'- 1
EXISTING
PANEL 'W2-EL'
'W2-E'- 2
'W2-E'- 6
'W2-E'- 18
'W2-E'- 10
'W2-E'- 12
'W2-E'- 14
'W2-E'- 8
'W2-E'- 16
'W2-E'- 4
'W2-E'- 3 'W2-E'- 24
'W2-E'- 1
'W2-E'- 22
'W2-E'- 5
PANEL 'SLP2A' PANEL 'SLP2B'
TRANSFORMER
'SLP2T'
AHU
ENCLOSURE
C2-211A
'W2-EL'- 13
'W2-E'- 20
AREA OF WORK LIMIT LINE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:4
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EP102B
SECOND FLOOR POWER PLAN - AREA
B
13 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
SECOND FLOOR POWER PLAN - AREA B
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
A. COORDINATE ELECTRICAL INSTALLATION WITH
CIVIL & STRUCTURAL DRAWINGS INCLUDED AS
PART OF THIS CONSTRUCTION DOCUMENT SET.
B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION
EQUIPMENT DIMENSIONS ARE BY: EATON.
CONTRACTOR IS RESPONSIBLE FOR SELECTING
EQUIPMENT THAT FITS WITHIN THE SIZE
CONSTRAINTS WITH PROPER CLEARANCES.
CONTRACTOR TO FURNISH SHOP DRAWINGS
SHOWING HOW EQUIPMENT PROPOSED WILL FIT
WITHIN THE SPACE CONSTRAINTS ALLOWED
WHILE MAINTAINING PROPER CLEARANCES PER
NEC-110.31, 110.32, AND MANUFACTURER
RECOMMENDATIONS.
C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C
(UNLESS OTHERWISE NOTED)
D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,
DUCT BANK, AND ELECTRICAL DETAILS FOR
INFORMATION REGARDING POWER FEED
CONSTRUCTION.
E. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.
LEGEND
1 EXISTING RECEPTACLE LOCATION. MAINTAIN
EXISTING BOX, REPLACE DEVICE AND
FACEPLATE. RECIRCUIT AS SHOWN.
2 CONNECT TO EXISTING NORMAL POWER CIRCUIT
SERVING THIS SAME AREA RETAINED DURING
DEMOLITION.
3 PROVIDE LIGHTNING PROTECTION SYSTEM ON
ROOF OF NEW AHU ENCLOSURE. CONNECT TO
EXISTING BUILDING LIGHTNING PROTECTION
SYSTEM.
4 PROVIDE JUNCTION BOXES FOR WATER CLOSET
AND LAVATORY SENSORS; CONNECT TO EXISTING
NORMAL POWER 120V CIRCUIT SERVING THIS
SAME AREA RETAINED DURING DEMOLITION, WITH
2-12 AWG, 1-12 AWG IN 3/4" CONDUIT.
COORDINATE LOCATION AND ELECTRICAL
REQUIREMENTS WITH PLUMBING CONTRACTOR.
5 PROVIDE JUNCTION BOXES AND 120V 20A CIRCUIT
FOR PACS DOOR POWER WITH 2-12 AWG, 1-12
AWG EG IN 3/4" CONDUIT.
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
2/20/2024
SOL# 36C77624R0079 Project # 693-352 Expand Mental Health Clinic Construction- Wilkes-Barre, PA
UP
M
M M
M
M
E
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
E
E
E
E
E
E E
E
M
MM
M
M
M E
M
J
E
M
M
M
N P Q R S T U V
V.9U.4
15.1
16.3
O
OFFICE/
CONSULT
C1-124
OFFICE/
CONSULT
C1-122
OFFICE/
CONSULT
C1-115OFFICE/
CONSULT
C1-114
OFFICE/
CONSULT
C1-113
OFFICE/
CONSULT
C1-112
MH
WAITING
C1-100
OFFICE/
CONSULT
C1-153 OFFICE/
CONSULT
C1-152
OFFICE/
CONSULT
C1-150
OFFICE/
CONSULT
C1-151
OFFICE/
CONSULT
C1-130
OFFICE/
CONSULT
C1-131
OFFICE/
CONSULT
C1-135
OFFICE/
CONSULT
C1-136
OFFICE/
CONSULT
C1-137
OFFICE/
CONSULT
C1-138
OFFICE/
CONSULT
C1-139
FAMILY
CONSULT
C1-140
OFFICE/
CONSULT
C1-129
OFFICE/
CONSULT
C1-128
OFFICE/
CONSULT
C1-127
GROUP
THERAPY
C1-126
STAFF
BREAK
ROOM
C1-161
MECHANICAL
C1-116
CORRIDOR
C-102
PATIENT
TOILET
C1-148
PATIENT
TOILET
C1-147
OFFICE/
CONSULT
C1-132
OFFICE/
CONSULT
C1-133
OFFICE/
CONSULT
C1-145
OFFICE/
CONSULT
C1-146
OFFICE/
CONSULT
C1-121
ELEC
C-101B
TELE-
HEALTH
C1-101
OFFICE/
CONSULT
C1-120
ELECTRICAL
C1-117OFFICE/
CONSULT
C1-119
ELEC
C1-67
MECH
C1-66
STAIR
STOR
C1-125
FAMILY
CONSULT
C1-149
NURSE
WORK
AREA
(7
NURSES)
C1-109
NURSE
WORK
AREA
C1-102
RECEPTION
C1-163
EXAM/
OFFICE/
CONSULT
C1-104
OFFICE/
CONSULT
C1-111
OFFICE/
CONSULT
C1-110
EXAM/
OFFICE/
CONSULT
C1-106
OFFICE/
CONSULT
C1-143
ELEC.
C1-118
OFFICE/
CONSULT
C1-123
EXAM/
OFFICE/
CONSULT
C1-105
VITALS
C-102B
SUITE
ACCESS
C-103A
TELE-
HEALTH
C1-103
SUITE
ACCESS
C-104
STAFF
LOCKERS
C1-160
FAMILY
CONSULT
C1-134
STOR
C1-141
MSA
C1-162
CORRIDOR
C-107
CORRIDOR
C-106
CORRIDOR
C-105
TR
C1-100A
CORRIDOR
C-101
MECH
C1-83
ELEV
LOBBY
C1-56C
STAFF TLT
C1-107
STAFF TLT
C1-108
OFFICE/
CONSULT
C1-142
OFFICE/
CONSULT
C1-144
HAC
C1-158
MEDS
C1-157
NURSE
WORK
AREA(1)
C-104A
EXAM/INJ
NURSE
OFFICE
C1-156
PROCEDURE/
TMS
C1-154STERILE
SUPPLY
C1-155
1E-VAV-2 1E-VAV-3
1E-VAV-5 1E-VAV-6 1E-VAV-8
1E-VAV-7
1E-VAV-9
1E-VAV-4
1E-VAV-16
1E-VAV-13
1E-VAV-11
1E-VAV-12
1E-VAV-14
1E-VAV-34
1E-VAV-35
1E-VAV-36 1E-VAV-37
1E-VAV-33
1E-VAV-32
1E-VAV-31
1E-VAV-15
1E-VAV-17 1E-VAV-18
1E-VAV-29
1E-VAV-20
1E-VAV-19
1E-VAV-27 1E-VAV-21
1E-VAV-25
1E-VAV-22
1E-AHU-1
1E-RF-1
STAIR
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
ELEV
MECH
C1-22G
MECHANICAL
BASEMENT
ROOF
CRAWL
SPACE
CRAWL
SPACE
BASEMENT
ROOF
BASEMENT
ROOF
1E-VAV-28
1E-VAV-23
1E-VAV-24
1E-VAV-26
'LP-3'- 5
1E-VAV-1
1E-VAV-10
'LP-3'- 8
'LP-3'- 7
'LP-3'- 2
14.6
1E-EF-2
1E-EF-1
1E-EF-3
1E-OU-21E-OU-1
1E-IU-2
1E-IU-1
1E-CP-1
1E-VAV-30
'A'- 14,16
'B'- 4,6
'LP-3'- 12
'LP-3'- 3
'LP-3'- 4
'LP-3'- 13
'LP-3'- 30
'ELP1'- 22,24,26
'ELP1'- 21,23,25
'LP-3'- 34
'LP-3'- 6
'LP-3'- 9
B A
B A
M A
T C
H L
IN
E
M A
T C
H L
IN
E
16.6
15.9
15.7
14.8
T.5S.6S.4 V.4V.1S.1
AREA OF WORK LIMIT LINE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:5
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EM101A
FIRST FLOOR MECHANICAL POWER
PLAN - AREA A
14 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
1 RADIATOR CONTROL VALVE PANEL, PROVIDE 20A
120V CIRCUIT WITH 2-12 AWG, 12 AWG EG, IN 3/4"
CONDUIT. COORDINATE LOCATION AND POWER
REQUIREMENTS WITH MECHANICAL
CONTRACTOR.
2 CONNECT TO EXISTING AHU SUPPLY FAN CIRCUIT
RETAINED DURING DEMOLITION. REPLACE
EXISTING CIRCUIT BREAKER WITH A 3P-40A .
PROVIDE FUSIBLE DISCONNECT FUSED PER
NAMEPLATE.
3 CONNECT TO EXISTING AHU RETURN FAN CIRCUIT
RETAINED DURING DEMOLITION. PROVIDE
FUSIBLE DISCONNECT FUSED PER NAMEPLATE.
Scale: 1/8" = 1'-0"
FIRST FLOOR MECHANICAL POWER PLAN - AREA A
NORTH
0 4 8 16
A. COORDINATE ELECTRICAL INSTALLATION WITH
CIVIL & STRUCTURAL DRAWINGS INCLUDED AS
PART OF THIS CONSTRUCTION DOCUMENT SET.
B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION
EQUIPMENT DIMENSIONS ARE BY: EATON.
CONTRACTOR IS RESPONSIBLE FOR SELECTING
EQUIPMENT THAT FITS WITHIN THE SIZE
CONSTRAINTS WITH PROPER CLEARANCES.
CONTRACTOR TO FURNISH SHOP DRAWINGS
SHOWING HOW EQUIPMENT PROPOSED WILL FIT
WITHIN THE SPACE CONSTRAINTS ALLOWED
WHILE MAINTAINING PROPER CLEARANCES PER
NEC-110.31, 110.32, AND MANUFACTURER
RECOMMENDATIONS.
C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C
(UNLESS OTHERWISE NOTED)
D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,
DUCT BANK, AND ELECTRICAL DETAILS FOR
INFORMATION REGARDING POWER FEED
CONSTRUCTION.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
DN
E
E
E
E
E
M
M
M M
M
M
E
S SS S S
S S
S SS S
S
S
S
S S
S S
S
S
S
S
S S
S S
S
S
S
S S
S S
S S
S S
S
S
D E F H J L MG
GROUP
MEETING
C1-65
ELEVATOR
LOBBY
C1-75
CORRIDOR
C-100
CORRIDOR
C1-69
STAIR
MECH
C1-83
CORRIDOR
C1-18
CORRIDOR
C1-16
CORRIDOR
C1-13
STORAGE
C1-65B
CONF
ROOM
A1-10
OFFICE
A1-09
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-11
EXAM
A1-14
EXAM
A1-16
EXAM
A1-07
EXAM
A1-06
EXAM
A1-20
EXAM
A1-15
EXAM
A1-12
EXAM
A1-23
CLEAN
LINEN
A1-02
T L T
A -2 A
EXAM
A1-27
ELEC
A1-03
ELEC
A1-30
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
P-3
ELEV
P-2
ELEV
P-1
CORR
A1-01
ATRIUM
CORR
A1-04
CORR
A1-13
STAIR
T L T
A -0 A
STAIR
VOLUNTARY
C1-77
STOR
C1-78A
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
IT
C1-21B
IT
C1-21C
IT
C1-22E
MECH
C1-22G
CRAWL
SPACE
STAIR
ELEV
LOBBY
A1-31A
SOILED
LINEN
A1-29
MECH
C1-04A
ELEC
C1-04
ELEC
C1-17A
ELEC
C1-17
A1-05
A1-28
CORR
A1-22A
HAC
A1-26
A1-22B
21-3
21-4
OFFICE
C1-74
OFFICE
C1-74A
OFFICE
C1-73
OFFICE
C1-72
OFFICE
C1-71
OFFICE
C1-70A
OFFICE
C1-70
OFFICE
C1-01B
OFFICE
C1-01A
ROI
C1-02
ROI
WAITING
C1-03
OFFICE
C1-03A
C1-01
TLT
C1-74B
CORRIDOR
21-14
C1-08
STORAGE
1-A
STORAGE
1-B
STORAGE
2-A
STORAGE
2-B
OFFICE
C1-12
OFFICE
C1-09
OFFICE
C1-10
OFFICE
C1-11
OFFICE
C1-06
OFFICE
C1-07
TOILET
C1-14
TOILET
C1-15
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
A B C
9.3
10.6
14.6
1W-FCU-3
1W-FCU-1
1W-FCU-5
1W-FCU-4
1W-FCU-6
HAC
C1-62
MEN'S
RESTROOM
C1-63
WOMEN'S
RESTROOM
C1-641W-FCU-2
IT
SERVER
RM
C1-19
IT
SERVER
RM
C1-20
IT
SERVER
RM
C1-21A
IT
SERVER
RM
C1-21
B A
B A
M A
T C
H L
IN
E
M A
T C
H L
IN
E
'LP-3'- 15
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:0
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EM101B
FIRST FLOOR MECHANICAL POWER
PLAN - AREA B
15 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
Scale: 1/8" = 1'-0"
FIRST FLOOR MECHANICAL POWER PLAN - AREA B
NORTH
0 4 8 16
A. COORDINATE ELECTRICAL INSTALLATION WITH
CIVIL & STRUCTURAL DRAWINGS INCLUDED AS
PART OF THIS CONSTRUCTION DOCUMENT SET.
B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION
EQUIPMENT DIMENSIONS ARE BY: EATON.
CONTRACTOR IS RESPONSIBLE FOR SELECTING
EQUIPMENT THAT FITS WITHIN THE SIZE
CONSTRAINTS WITH PROPER CLEARANCES.
CONTRACTOR TO FURNISH SHOP DRAWINGS
SHOWING HOW EQUIPMENT PROPOSED WILL FIT
WITHIN THE SPACE CONSTRAINTS ALLOWED
WHILE MAINTAINING PROPER CLEARANCES PER
NEC-110.31, 110.32, AND MANUFACTURER
RECOMMENDATIONS.
C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C
(UNLESS OTHERWISE NOTED)
D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,
DUCT BANK, AND ELECTRICAL DETAILS FOR
INFORMATION REGARDING POWER FEED
CONSTRUCTION.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
M
M E
S S
S S
SS
S S
S
Q R S T U V
CORRIDOR
C2-26
WAITING
TOILET
STAIR
2E-VAV-1
CLOSET
C2-42A
CARDIAC
REHAB
C2-40
OFFICE
C2-40A
OFFICE
C2-39A
RECREATION
THERAPY
C2-39
MECHANICAL
RM
C2-39B
ELECTRICAL
C2-39C
TOILET
C2-41B
TOILET
C2-41A
OT
CLINIC
OFFICE
C2-42
VESTIBULE
MECH
C2-36
TOILET
C2-38
TOILET
C2-37
OFFICE
C2-35
CONFERENCE
RM
C2-35A
OFFICE
C2-34
TOILET
C2-33A
BARIATRIC
ULTRASOUND
EXAM
C2-33B
TOILET
C2-33C
SOILED
UTILITY
C2-33D
BARIATRIC
ULTRASOUND
EXAM
C2-33E
ULTRASOUND
EXAM
C2-31B
ULTRASOUND
WAITING
C2-29
ULTRASOUND
TECHS/FILES
C2-30
ULTRASOUND
EXAM
C2-31A
CLEAN
HOLDING
C2-31D
TOILET
C2-31C
CORRIDOR
C2-32
CORRIDOR
C2-32A
FILE
RM
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
OFFICE
STRESS
LAB
BREAK
RM
PRE-TEST
C2-25
CORRIDOR
C2-26
OFFICE
C2-24D
OFFICE
C2-24C
MECH
C2-27A
ELEC
C2-27
TOILET
C2-28
CORRIDOR
'LP-3'- 10
2E-EF-1
'LP-3'- 11
16.6
15.7
14.8
S.4S.1
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:1
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EM102A
SECOND FLOOR MECHANICAL POWER
PLAN - AREA A
16 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
SECOND FLOOR MECHANICAL POWER PLAN - AREA A
A. COORDINATE ELECTRICAL INSTALLATION WITH
CIVIL & STRUCTURAL DRAWINGS INCLUDED AS
PART OF THIS CONSTRUCTION DOCUMENT SET.
B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION
EQUIPMENT DIMENSIONS ARE BY: EATON.
CONTRACTOR IS RESPONSIBLE FOR SELECTING
EQUIPMENT THAT FITS WITHIN THE SIZE
CONSTRAINTS WITH PROPER CLEARANCES.
CONTRACTOR TO FURNISH SHOP DRAWINGS
SHOWING HOW EQUIPMENT PROPOSED WILL FIT
WITHIN THE SPACE CONSTRAINTS ALLOWED
WHILE MAINTAINING PROPER CLEARANCES PER
NEC-110.31, 110.32, AND MANUFACTURER
RECOMMENDATIONS.
C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C
(UNLESS OTHERWISE NOTED)
D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,
DUCT BANK, AND ELECTRICAL DETAILS FOR
INFORMATION REGARDING POWER FEED
CONSTRUCTION.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
E
E
M
M
M
M M
M
M
M
M M
E
M
E
E
M
S SS
S S
S
S SS
S S
S S
D E
TRAINING
ROOM
C2-211
OFFICE
C2-207
HOLDING
C2-205
INTERVIEW
ROOM
C2-206
WOMEN'S
LOCKERS
C2-214
OFFICE
C2-202
ARMORY
C2-210
BREAK
AREA
C2-216
CORRIDOR
C2-200
OFFICE
C2-209
MEN'S TLT
C2-213
MEN'S
LOCKERS
C2-212
WOMEN'S
TLT
C2-215
OFFICE
C2-208
ENTRANCE
C2-204
RECEPTION
C2-203 OFFICE
C2-201
WEAPONS
C2-210A
2W-VAV-9
2W-VAV-2
2W-VAV-4
2W-VAV-1
2W-VAV-3
2W-VAV-7 2W-VAV-8
2W-VAV-6
2W-VAV-52W-VAV-10
2W-EF-1
TOUCHDOWN
A5-005
EXAM
RM
A2-007
EXAM
RM
A2-011
TOILET
A2-009A
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A CHECK-IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
CORRIDOR
A2-013
A2-002
STAIR
CORRIDOR
C2-11
OFFICE
C2-04
OFFICE
C2-03
MECH
C2-10
ELEC
C2-02
STORAGE
C2-05B
OFFICE
C2-05A
STAIR
2-002
STAIR
CORRIDOR
A2-001
CORRIDOR
C2-32
'W2-E'- 7
'W2-E'- 9
A B CA.2 B.3
9.3
10.6
'SLP2B'- 2
'SLP2A'- 2,4,6
'SLP2A'- 7,9,11
'SLP2B'- 7
'SLP2B'- 5
AHU
ENCLOSURE
C2-211A
2W-AHU-1
2W-VAV-11
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:1
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EM102B
SECOND FLOOR MECHANICAL POWER
PLAN - AREA B
17 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
SECOND FLOOR MECHANICAL POWER PLAN - AREA B
A. COORDINATE ELECTRICAL INSTALLATION WITH
CIVIL & STRUCTURAL DRAWINGS INCLUDED AS
PART OF THIS CONSTRUCTION DOCUMENT SET.
B. BASIS OF DESIGN ELECTRICAL DISTRIBUTION
EQUIPMENT DIMENSIONS ARE BY: EATON.
CONTRACTOR IS RESPONSIBLE FOR SELECTING
EQUIPMENT THAT FITS WITHIN THE SIZE
CONSTRAINTS WITH PROPER CLEARANCES.
CONTRACTOR TO FURNISH SHOP DRAWINGS
SHOWING HOW EQUIPMENT PROPOSED WILL FIT
WITHIN THE SPACE CONSTRAINTS ALLOWED
WHILE MAINTAINING PROPER CLEARANCES PER
NEC-110.31, 110.32, AND MANUFACTURER
RECOMMENDATIONS.
C. 20A 120V CIRCUIT CONDUCTORS AND CONDUITS
SHALL BE: 2-12 AWG, 1-12 AWG EG IN 3/4" C
(UNLESS OTHERWISE NOTED)
D. SEE SINGLE-LINE DIAGRAM, FEEDER SCHEDULE,
DUCT BANK, AND ELECTRICAL DETAILS FOR
INFORMATION REGARDING POWER FEED
CONSTRUCTION.
E. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
ETR
ETR
VSD VSD VSD VSD VSD
VSD
VSD
VSD VSD VSDVSD
VSD
VSD
V S
D V
S D
LV
LVD
VSD
V S
D
VSD
V S
D V
S D
V S
D
V S
D
VSD VSD VSDVSD
VSD
V S
D
VSD
VSDVSD VSD
V S
OS OS
VS
LVD LVD
VS
VS
VS
LVD
LVD
VSD
VS
VSD
VSD
VSD
VS
OSD
OSOS
OS
OS
VS
VSD
OSDOSDOSD
OSD
OSD
OS
OS
OS
OS
OS
LVD
LVD
VSD
VSD
LVD
LV
D
LV
DLVD
LVD
VS
LVD
OS OS
OS
OS OS OS
OS
OS
OS
OS
OS OS OS
OS
LVD
LVD
LVD
LVD
LVD
SS
N P Q R S T U V
V.9U.4
15.1
16.3
OFFICE/
CONSULT
C1-124
OFFICE/
CONSULT
C1-122
OFFICE/
CONSULT
C1-115
OFFICE/
CONSULT
C1-114
OFFICE/
CONSULT
C1-113
OFFICE/
CONSULT
C1-112
MH
WAITING
C1-100
OFFICE/
CONSULT
C1-153
OFFICE/
CONSULT
C1-152
OFFICE/
CONSULT
C1-150
OFFICE/
CONSULT
C1-151
OFFICE/
CONSULT
C1-130
OFFICE/
CONSULT
C1-131
OFFICE/
CONSULT
C1-135
OFFICE/
CONSULT
C1-136
OFFICE/
CONSULT
C1-137
OFFICE/
CONSULT
C1-138
OFFICE/
CONSULT
C1-139
HAC
C1-158
FAMILY
CONSULT
C1-140
OFFICE/
CONSULT
C1-129
OFFICE/
CONSULT
C1-128
OFFICE/
CONSULT
C1-127
GROUP
THERAPY
C1-126
STAFF
BREAK
ROOM
C1-161
MECHANICAL
C1-116
CORRIDOR
C-102
PATIENT
TOILET
C1-148
PATIENT
TOILET
C1-147
OFFICE/
CONSULT
C1-132
OFFICE/
CONSULT
C1-133
OFFICE/
CONSULT
C1-145
OFFICE/
CONSULT
C1-146
OFFICE/
CONSULT
C1-121
STAFF TLT
C1-107
ELEC
C-101B
TELE-
HEALTH
C1-101
OFFICE/
CONSULT
C1-120
ELECTRICAL
C1-117
OFFICE/
CONSULT
C1-119
ELEC
C1-67
MECH
C1-66
STAIR
STAFF TLT
C1-108
NURSE
WORK
AREA(1)
C-104A
STOR
C1-125
FAMILY
CONSULT
C1-149
NURSE
WORK
AREA
(7
NURSES)
C1-109
NURSE
WORK
AREA
C1-102
RECEPTION
C1-163
MEDS
C1-157
EXAM/
OFFICE/
CONSULT
C1-104
PROCEDURE/
TMS
C1-154
OFFICE/
CONSULT
C1-111
OFFICE/
CONSULT
C1-110
EXAM/
OFFICE/
CONSULT
C1-106
OFFICE/
CONSULT
C1-143
ELEC.
C1-118
OFFICE/
CONSULT
C1-123
EXAM/INJ
NURSE
OFFICE
C1-156
EXAM/
OFFICE/
CONSULT
C1-105
VITALS
C-102B
SUITE
ACCESS
C-103A
TELE-
HEALTH
C1-103
SUITE
ACCESS
C-104
STAFF
LOCKERS
C1-160
FAMILY
CONSULT
C1-134
STOR
C1-141
MSA
C1-162
CORRIDOR
C-106
CORRIDOR
C-105
TR
C1-100A
CORRIDOR
C-101
ELEV
LOBBY
C1-56C
STERILE
SUPPLY
C1-155
OFFICE/
CONSULT
C1-142
OFFICE/
CONSULT
C1-144
O
CORRIDOR
C-107
RCD2
RCD2
MECH
ELEV
ELEV
ELEV
ELEV
ELEV
ELEV
MECHANICAL
C1-22C
MECHANICAL
BASEMENT
ROOF
CRAWL
SPACE
CRAWL
SPACE
BASEMENT
ROOF
BASEMENT
ROOF
ETR
ETR
ETR
ETR
ETR
ETR
A1E A1 A1E
A1
A1E
A1E A1 A1 A1E A1E A1 A1E
D1 D1 D1 D1 D1 D1
A1E
D1
D1 D1
A1
A1E
A1
A1 A1
A1A1
A1
A1
A1
A1E
A1
A1
A1E
A1
A1 A1 A1
A1A1
A1A1
A1A1
A1
A1
A2
A2
A1
A1
A1 A1
A1 A1
A1
A1 A1
A1
A1 A1
A1
A1
A1
A1
A1
A1
A1
A1 A1 A1 A1
A1
A1
A1
A1
A2A2 A2
A1 A1
A1
K1
K1
J1 J1
H1
A1
A1E A1A1A1E
A1
A1
A1
A1
A2
A2
A3
A3
B1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A2
A1
A3F
M1
A1E
A1 A1E A1 A1 A1E A1
A1
A1E
A1 A1 A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1 A1E
A1 A1
A1
C1
C1
C1
C1
A3
A3
A3
A3
A3
A3
A3
A3
A2
A2E
A2
C1
C1
C1
D1
D1
D1
D1
D1
D1
D1
N1
N1N1 N1
N1 N1 D1
D1
D1
E1
E1
E1
E2
E1
E1
E1
E2
E1
E2
E2
E2E2
M1
14.6
A1A1
ETR
CORRIDOR
C-103
M1
RCD2
RCD
RCD
b b b aaa a ba,b a,b
'A'- 2 c c d dc,d dc c,d
RCD2
RCD2 e f g h h g h h g g g,h
RCD
e e e e e e f f f f e,f f f f f f f e,f e,f
B1
H1
A1
CORRIDOR
C-102A
D1
D1
D1
D1D1
STOR.
C1-103B
C1 m l m l m l,m
D1
D1
'LP-3'- 16
'LP-3'- 18
'LP-3'- 20
'LP-3'- 22
'LP-3'- 24
M1
M1
RCD
RCD
'LP-3'- 26
RCD
RCD
'LP-3'- 28
M1 M1M1
B A
B A
M A
T C
H L
IN
E
M A
T C
H L
IN
E
16.6
15.9
15.7
14.8
T.5S.6S.4 V.4V.1S.1
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:2
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EL111A
FIRST FLOOR LIGHTING PLAN - AREA A
18 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
Scale: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN - AREA A
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
NORTH
0 4 8 16
A. LOCATION AND QUANTITY OF OCCUPANCY
SENSORS AND LIGHT LEVEL SENSORS ARE
APPROXIMATE. CONTRACTOR SHALL FOLLOW
MANUFACTURER'S RECOMMENDED PLACEMENT
AND INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF
ALL LIGHTING CONTROLS WITH THE LED
DRIVERS TO BE CONTROLLED.
C. COORDINATE ALL TIME DELAY, AUTO DIM,
PRESET DIMMING LEVELS, SENSOR SENSITIVITY
AND OTHER CONFIGURATIONS WITH THE VA
COR.
D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,
SHOWN ON THIS PLAN, SHALL BE CIRCUITED
FROM LIFE SAFETY EMERGENCY LIGHTING
CIRCUIT 'EELS1A'-2, BUT AHEAD OF ANY
SWITCHING.
E. ALL INTERIOR SWITCHED EMERGENCY
LIGHTING, SHOWN ON THIS PLAN, SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL.
DURING NORMAL NON-EMERGENCY CONDITION
LIGHT FIXTURES SHALL BE SWITCHED WITH
NORMAL LIGHTING AS SHOWN. SEE DETAIL
8/E-501. NORMAL POWER CIRCUIT AS SHOWN
ON PLAN. LIFE SAFETY EMERGENCY POWER
CIRCUIT 'EELS1A'-2.
F. ALL EXTERIOR BUILDING MOUNTED LIGHTING IS
CONTROLLED BY PHOTOCELL AND
ASTRONOMICAL TIME CLOCK.
G. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.
H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT
LIGHTING CONDUCTORS SHALL BE 2-12 AWG,
1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED
OTHERWISE.
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM
2-10 AWG, 1-10 AWG EG IN 3/4" C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
OS
VSD
OS OS
LVD LVD
OS
OS
LVD
LVD
VSD
OS OS OS OS
OS
OS OS OS OS OS OS
LVDLVD
LVD
LVD
S SS S S
S S
S SS S
S
SS S
S S
S S
S S
S S
S
S
S
S
S
S S
S S
S
S S
S S
S S
S SS S S S S S
S S
S
S
S
S
S S S
S S
S
S
D E F H J L M
GROUP
MEETING
C1-65
ELEVATOR
LOBBY
C1-75
CORRIDOR
C-100
CORRIDOR
C1-69
WOMEN'S
RESTROOM
C1-64
CORRIDOR
C1-18
CORRIDOR
C1-16
CORRIDOR
C1-13
STORAGE
C1-65B
SILVER
ELEV
LOBBY
C1-75
G
CONF
ROOM
A1-10
OFFICE
A1-09
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-11
EXAM
A1-14
EXAM
A1-16
EXAM
A1-07
EXAM
A1-06
EXAM
A1-20
EXAM
A1-15
EXAM
A1-12
EXAM
A1-23
CLEAN
LINEN
A1-02
T L T
A -2 A
EXAM
A1-27
ELEC
A1-03
ELEC
A1-30
ELEV
S-1
ELEV
S-2
ELEV
S-3
ELEV
P-3
ELEV
P-2
ELEV
P-1
CORR
A1-01
ATRIUM
CORR
A1-04
CORR
A1-13
STAIR
T L T
A -0 A
STAIR
VOLUNTARY
C1-77
STOR
C1-78A
ELEC
C1-76
MECH
C1-78
MECH
ELEV
ELEV
ELEV
ELEV
IT
C1-21B
IT
C1-21C
MECHANICAL
C1-22C
IT
C1-22E
MECH
C1-22G
CRAWL
SPACE
STAIR
ELEV
LOBBY
A1-31A
SOILED
LINEN
A1-29
MECH
C1-04A
ELEC
C1-04
ELEC
C1-17A
ELEC
C1-17
A1-05
A1-28
CORR
A1-22A
HAC
A1-26
A1-22B
21-3
21-4
OFFICE
C1-74
OFFICE
C1-74A
OFFICE
C1-73
OFFICE
C1-72
OFFICE
C1-71
OFFICE
C1-70A
OFFICE
C1-70
OFFICE
C1-01B
OFFICE
C1-01A
ROI
C1-02
ROI
WAITING
C1-03
OFFICE
C1-03A
C1-01
TLT
C1-74B
CORRIDOR
21-14
C1-08
STORAGE
1-A
STORAGE
1-B
STORAGE
2-A
STORAGE
2-B
OFFICE
C1-12
OFFICE
C1-09
OFFICE
C1-10
OFFICE
C1-11
OFFICE
C1-06
OFFICE
C1-07
TOILET
C1-14
TOILET
C1-15
MY
HEALTH
VET
C1-05
OFFICE
C1-68
OFFICE
C1-67
OFFICE
C1-66
RCD2
A1 A1E A1 A1 A1E A1 D1 D1
A1 A1E A1
A1
A1E
A1 A1E A1 A1 A1E A1
A1
A1E
H1
H1
H1 H1 H1
B1
B1E B1E
B1 B1
B1
D1
D1
D1
A2
N1
N1
D1
D1
D1
D1 D1
D1
D1
E1
E2
E1
A1
A1E
A1
E2
A B C
ETR
ETR
ETR
ETR
ETR
e e e,f j j k k kk kj kj
RCD
RCD
B1
B1
B1 j,k j j
MEN'S
RESTROOM
C1-63
HAC
C1-62
A1
3 3
RCD
IT
SERVER
RM
C1-19
IT
SERVER
RM
C1-20
IT
SERVER
RM
C1-21A
IT
SERVER
RM
C1-21
B A
B A
M A
T C
H L
IN
E
M A
T C
H L
IN
E
AREA OF WORK LIMIT LINE
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:3
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EL111B
FIRST FLOOR LIGHTING PLAN - AREA B
19 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
Scale: 1/8" = 1'-0"
FIRST FLOOR LIGHTING PLAN - AREA B
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
NORTH
0 4 8 16
A. LOCATION AND QUANTITY OF OCCUPANCY
SENSORS AND LIGHT LEVEL SENSORS ARE
APPROXIMATE. CONTRACTOR SHALL FOLLOW
MANUFACTURER'S RECOMMENDED PLACEMENT
AND INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF
ALL LIGHTING CONTROLS WITH THE LED
DRIVERS TO BE CONTROLLED.
C. COORDINATE ALL TIME DELAY, AUTO DIM,
PRESET DIMMING LEVELS, SENSOR SENSITIVITY
AND OTHER CONFIGURATIONS WITH THE VA
COR.
D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,
SHOWN ON THIS SHEET, SHALL BE CIRCUITED
FROM NEAREST LIFE SAFETY EMERGENCY
LIGHTING CIRCUIT AS INDICATED ON PLAN, BUT
AHEAD OF ANY SWITCHING.
E. ALL INTERIOR SWITCHED EMERGENCY
LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL.
DURING NORMAL NON-EMERGENCY CONDITION
LIGHT FIXTURES SHALL BE SWITCHED WITH
NORMAL LIGHTING AS SHOWN. SEE DETAIL
8/E-501. NORMAL POWER AND LIFE SAFETY
EMERGENCY POWER CIRCUIT AS INDICATED ON
PLAN.
F. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.
G. ALL 120 VOLT 20 AMP BRANCH CIRCUIT
LIGHTING CONDUCTORS SHALL BE 2-12 AWG,
1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED
OTHERWISE.
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM
2-10 AWG, 1-10 AWG EG IN 3/4" C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
1 CONNECT TO EXISTING NORMAL LIGHTING
CIRCUIT SERVING THIS SAME AREA, RETAINED
DURING DEMOLITION.
2 CONNECT TO EXISTING CORRIDOR NORMAL
LIGHTING CIRCUIT SERVING THIS SAME AREA,
RETAINED DURING DEMOLITION.
3 CONNECT TO EXISTING CORRIDOR LIFE SAFETY
LIGHTING CIRCUIT, RETAINED DURING
DEMOLITION.
4 CONNECT TO EXISTING LIFE SAFETY LIGHTING
CIRCUIT SERVING THIS SAME AREA, RETAINED
DURING DEMOLITION.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
OS
OS
LVD
LVD
S S
S S
SS
S S
S
R S T
OFFICE
C2-40A
OFFICE
C2-39A
RECREATION
THERAPY
C2-39
MECHANICAL
RM
C2-39B
ELECTRICAL
C2-39C
VESTIBULE
MECH
C2-36
TOILET
C2-38
TOILET
C2-37
OFFICE
C2-35
CONFERENCE
RM
C2-35A
OFFICE
C2-34
TOILET
C2-33A
BARIATRIC
ULTRASOUND
EXAM
C2-33B
SOILED
UTILITY
C2-33D
ULTRASOUND
WAITING
C2-29
ULTRASOUND
TECHS/FILES
C2-30
CLEAN
HOLDING
C2-31D
CORRIDOR
C2-32A
FILE
RM
OFFICE
OFFICE
OFFICE
CORRIDOR
C2-26
MECH
C2-27A
ELEC
C2-27
TOILET
C2-28
CORRIDOR
WAITING
TOILET
STAIR
CORRIDOR
C2-26
A1A1
B1
H1
W1E
A2E
A2
A2E
E1
E1
A1E
STAIR EXIT
CORRIDOR
2C
RCD
RCD
A2
16.6
15.7
14.8
S.4S.1
STOR
CG-18C
LOCKER
CG-22
STORAGE
CG-23
STORAGE
CG-25
STORAGE
CG-26
BREAK
RM
CG-28
WASTE
MANAGEMENT
EG-45
CART
WASH
FG-43
REFR
CG-53
REFR
CG-52
MECHANICAL
RM
CG-51A
WM
CG-51
CORRIDOR
CG-49
MECH
CG-20A
REPRODUCTION
OFFICE
CG-59
REPRODUCTION
OFFICE
CG-58
EMS
STORAGE
CG-57
BREAL
RM
CG-56
TOILET
CG-21
CORRIDOR
CG-61A
STORAGE
RM
CG-64
CORRIDOR
CG-54
CORRIDOR
LD-2
ELEC
CG-20
STAIR
CG-20B
STORAGE RM
ELEC
STOR
CG-18A
CG-61C
CG-55
LD-1
S T U V
W1E W1E W1E
'LP-3'- 32
W1E
'EELS1A'- 4
10'-0"
AFF
10'-0"
AFF
E1
AREA OF WORK LIMIT LINE
P1E
P1E
P1E
'EELS1A'- 4
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:4
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EL112A
SECOND, GROUND FLOOR AND SITE
LIGHTING PLANS - AREA A
20 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
SECOND FLOOR LIGHTING PLAN - AREA A
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
A. LOCATION AND QUANTITY OF OCCUPANCY
SENSORS AND LIGHT LEVEL SENSORS ARE
APPROXIMATE. CONTRACTOR SHALL FOLLOW
MANUFACTURER'S RECOMMENDED PLACEMENT
AND INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF
ALL LIGHTING CONTROLS WITH THE LED
DRIVERS TO BE CONTROLLED.
C. COORDINATE ALL TIME DELAY, AUTO DIM,
PRESET DIMMING LEVELS, SENSOR SENSITIVITY
AND OTHER CONFIGURATIONS WITH THE VA
COR.
D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,
SHOWN ON THIS SHEET, SHALL BE CIRCUITED
FROM NEAREST LIFE SAFETY EMERGENCY
LIGHTING CIRCUIT AS INDICATED ON PLAN, BUT
AHEAD OF ANY SWITCHING.
E. ALL INTERIOR SWITCHED EMERGENCY
LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL.
DURING NORMAL NON-EMERGENCY CONDITION
LIGHT FIXTURES SHALL BE SWITCHED WITH
NORMAL LIGHTING AS SHOWN. SEE DETAIL
8/E-501. NORMAL POWER AND LIFE SAFETY
EMERGENCY POWER CIRCUITS AS INDICATED
ON PLAN.
F. ALL EXTERIOR BUILDING MOUNTED LIGHTING IS
CONTROLLED BY PHOTOCELL AND
ASTRONOMICAL TIME CLOCK.
G. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.
H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT
LIGHTING CONDUCTORS SHALL BE 2-12 AWG,
1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED
OTHERWISE.
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM
2-10 AWG, 1-10 AWG EG IN 3/4" C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
Scale: 1/8" = 1'-0"
GROUND FLOOR LIGHTING PLAN - AREA A
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
GROUND
FLOOR
AREA OF
WORK
GROUND FLOOR
SECOND FLOOR
1 CONNECT TO EXISTING STAIR 2 LIFE SAFETY
LIGHTING CIRCUIT AND CONTROLS.
2 CONNECT TO EXISTING NORMAL LIGHTING
CIRCUIT SERVING THIS SAME AREA, RETAINED
DURING DEMOLITION.
3 CONNECT TO NEAREST EXISTING CORRIDOR LIFE
SAFETY LIGHTING CIRCUIT, RETAINED DURING
DEMOLITION.
LEGEND
NORTH
0 105 20
Scale: 1" = 10'-0"
ELECTRICAL SITE LIGHTING PLAN
NORTH
0 4 8 16
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
LVD LVD LVD
VS
VS
VSD
VSD
VSD
VSD
VSD
OSD
VSD
OS
OSD VSD
VSD VSD
VSD
LVD
OS OS
OS
LVD
S SS
S S
S
S SS
S S
S S
D E
TRAINING
ROOM
C2-211
OFFICE
C2-207
HOLDING
C2-205
INTERVIEW
ROOM
C2-206
WOMEN'S
LOCKERS
C2-214
OFFICE
C2-202
ARMORY
C2-210
BREAK
AREA
C2-216
CORRIDOR
C2-200
OFFICE
C2-209
MEN'S TLT
C2-213
MEN'S
LOCKERS
C2-212
WOMEN'S
TLT
C2-215
OFFICE
C2-208
ENTRANCE
C2-204
RECEPTION
C2-203
OFFICE
C2-201
TOUCHDOWN
A5-005
EXAM
RM
A2-007
EXAM
RM
A2-011
TOILET
A2-009A
TOILET
A2-009
OFFICE
A2-010
STAFF
TOILET
A2-008
WAITING
RM
A2-003
TOILET
A2-05A CHECK-IN
A2-004
CLEAN
LINEN
A2-18
SOILED
A2-017
A2-002
STAIR
CORRIDOR
C2-11
OFFICE
C2-04
OFFICE
C2-03
MECH
C2-10
ELEC
C2-02
STORAGE
C2-05B
OFFICE
C2-05A
STAIR
2-002
STAIR
CORRIDOR
A2-001
CORRIDOR
C2-32
RCD2
RCD
A2
A1
C1
B1
A2E
A1
A1
A1E
A2E
A2 A2
B1
B1B1
A1
A1
A1
A1
A1
A1
A1 C1 C1
C1
C1
L1 L1
A1E
A2
A2
A1 A1
A1A1
B1 B1
B1B1
F1 F1
L1E
H1
H1
M1
E1
E2
E1
E1
C1
C1
C1
C1
C1C1
C1
C1
C1
F1
A B CA.2 B.3
9.3
10.6
WEAPONS
C2-210A
M1
C1
'SLP2B'- 3
RCD
RCD
a a b b a b a,b a,b
'W2-E'- 11
'W2-E'- 13
AHU
ENCLOSURE
C2-211A
C1
AREA OF WORK LIMIT LINE
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - SMOKE BARRIER
/1
/2
:0
:4
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
EL112B
SECOND FLOOR LIGHTING PLAN -
AREA B
21 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
NORTH
0 4 8 16
Scale: 1/8" = 1'-0"
SECOND FLOOR LIGHTING PLAN - AREA B
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
A. LOCATION AND QUANTITY OF OCCUPANCY
SENSORS AND LIGHT LEVEL SENSORS ARE
APPROXIMATE. CONTRACTOR SHALL FOLLOW
MANUFACTURER'S RECOMMENDED PLACEMENT
AND INSTALL PER MANUFACTURER'S
INSTRUCTIONS.
B. CONTRACTOR SHALL VERIFY COMPATIBILITY OF
ALL LIGHTING CONTROLS WITH THE LED
DRIVERS TO BE CONTROLLED.
C. COORDINATE ALL TIME DELAY, AUTO DIM,
PRESET DIMMING LEVELS, SENSOR SENSITIVITY
AND OTHER CONFIGURATIONS WITH THE VA
COR.
D. ALL INTERIOR UN-SWITCHED EXIT SIGNS,
SHOWN ON THIS SHEET, SHALL BE CIRCUITED
FROM LIFE SAFETY EMERGENCY LIGHTING
CIRCUIT 'W2-EL'-9, BUT AHEAD OF ANY
SWITCHING.
E. ALL INTERIOR SWITCHED EMERGENCY
LIGHTING, SHOWN ON THIS SHEET, SHALL HAVE
BOTH NORMAL AND EMERGENCY POWER.
DURING EMERGENCY CONDITION THE
GENERATOR TRANSFER DEVICE SHALL DETECT
NORMAL POWER VOLTAGE LOSS, TRANSFER TO
EMERGENCY POWER AND RETURN TO FULL-
OUTPUT UPON LOSS OF CONTROL SIGNAL.
DURING NORMAL NON-EMERGENCY CONDITION
LIGHT FIXTURES SHALL BE SWITCHED WITH
NORMAL LIGHTING AS SHOWN. SEE DETAIL
8/E-501. NORMAL POWER CIRCUIT AS SHOWN
ON PLAN. LIFE SAFETY EMERGENCY POWER
CIRCUIT 'W2-EL'-9.
F. SEE E-601 FOR LIGHT FIXTURE SCHEDULE.
G. SEE SHEET E-001 FOR DEDUCTIVE ALTERNATES.
H. ALL 120 VOLT 20 AMP BRANCH CIRCUIT
LIGHTING CONDUCTORS SHALL BE 2-12 AWG,
1-12 AWG EG IN 3/4" CONDUIT UNLESS NOTED
OTHERWISE.
a. RUNS LESS THAN 150' SHALL BE MINIMUM
2-12 AWG, 1-12 AWG EG IN 3/4" C.
b. RUNS BETWEEN 150'-250' SHALL BE MINIMUM
2-10 AWG, 1-10 AWG EG IN 3/4" C.
c. RUNS GREATER THAN 250' SHALL BE
MINIMUM 2-8 AWG, 1-8 AWG EG IN 3/4" C.
LEGEND
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
BOND TO INTERIOR METAL
COLD WATER PIPING
GROUNDING ELECTRODE CONDUCTOR
GROUNDING BAR-BOND TO ENCLOSURE
COMMUNICATION GROUND
BAR. SEE TELECOM
BOND TO STRUCTURAL STEEL (MIN. 1/2"
BAR) IN FOOTING-CONDUCTOR SHALL
BE CONTINUOUS FROM GROUND BAR
TO GROUND ROD
GROUNDING ELECTRODE CONDUCTOR
BOND TO 3-3/4" X 10'
COPPERCLAD STEEL
DRIVEN GROUND
RODS - SPACE 10'
APART
EQUILATERALLY
NOTES:
1. GROUNDING CONDUCTORS AND
MAIN BONDING JUMPER SHALL BE
BARE COPPER UNO AND SHALL BE
SIZED AS INDICATED ON SINGLE LINE.
2. ALL AVAILABLE GROUND
ELECTRODES SHALL BE USED.
LIGHTNING PROTECTION
GROUNDING SHALL ALSO BE
BONDED TO THE GROUNDING
ELECTRODE SYSTEM.
SERVICE
EQUIPMENT
N
G B
TMGB
3/4" PVC CONDUIT - TYPICAL FOR GROUNDING
ELECTRODE CONDUCTOR CONDUIT
NEUTRAL (GROUNDED
CONDUCTOR) BAR
MAIN BONDING JUMPER
SIZE PER SINGLE-LINE
BOND EQUIPMENT
GROUNDING CONDUCTOR
TO SERVICE RACEWAY(S)
BOND TO METAL
UNDERGROUND WATER
PIPE ON SUPPLY SIDE OF
MAIN COLD WATER VALVE
1. FLOOR OR WALL ASSEMBLY - MIN 4-1/2 IN. (114 MM) THICK LIGHTWEIGHT OR NORMAL WEIGHT (100-150 PCF OR 1600-2400 KG/M3) CONCRETE. WALL MAY ALSO BE CONSTRUCTED OF ANY UL CLASSIFIED CONCRETE
BLOCKS*. MAX DIAM OF CIRCULAR THROUGH OPENING IS 32-1/2 IN. (826 MM).
SEE CONCRETE BLOCKS (CAZT) CATEGORY IN THE FIRE RESISTANCE DIRECTORY FOR NAMES OF
MANUFACTURERS.
1A. STEEL SLEEVE (OPTIONAL, NOT SHOWN) - NOM 12 IN. (305 MM) DIAM (OR SMALLER) SCHEDULE 40 (OR HEAVIER) STEEL PIPE SLEEVE CAST INTO CONCRETE FLOOR OR WALL. SLEEVE TO BE FLUSH WITH OR PROJECT MAX 2 IN. (51MM) FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF WALL.
2. THROUGH PENETRANT - ONE METALLIC PIPE, CONDUIT OR TUBING INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE BETWEEN PIPE, CONDUIT OR TUBING AND PERIPHERY OF OPENING SHALL BE MIN OF 0 IN. (0 MM)(POINT CONTACT) TO MAX 1-3/8 IN. (35 MM).
PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING
TYPES AND SIZES OF METALLIC PIPES, CONDUITS OR TUBING MAY BE USED:
A. STEEL PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) SCHEDULE 10 (OR HEAVIER) STEEL PIPE.
A1. IRON PIPE - NOM 30 IN. (762 MM) DIAM (OR SMALLER) CAST OR DUCTILE IRON PIPE.
B. CONDUIT - NOM 6 IN. (152 MM) DIAM (OR SMALLER) RIGID STEEL CONDUIT.
C. CONDUIT - NOM 4 IN. (102 MM) DIAM (OR SMALLER) STEEL ELECTRICAL METALLIC TUBING.
3. PACKING MATERIAL - POLYETHYLENE BACKER ROD OR NOM 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC (ALUMINA SILICA) FIBER BLANKET, MINERAL WOOL BATT OR GLASS FIBER INSULATION MATERIAL USED AS A PERMANENT FORM. PACKING MATERIAL TO BE RECESSED FROM TOP SURFACE OF FLOOR OR FROM BOTH SURFACES OF SOLID CONCRETE OR CONCRETE BLOCK WALL AS REQUIRED TO ACCOMMODATE THE REQUIRED THICKNESS OF CAULK FILL MATERIAL (ITEM 4). AS AN ALTERNATE WHEN MAX PIPE SIZE IS 10 IN. (254 MM) DIAM AND WHEN MAX ANNULAR SPACE IS 1 IN. (25 MM), A MIN 1 IN. (25 MM) THICKNESS OF TIGHTLY-PACKED CERAMIC FIBER BLANKET OR MINERAL WOOL BATT PACKING MATERIAL MAY BE RECESSED MIN 1/2 IN. (13 MM) FROM BOTTOM SURFACE OF FLOOR OR FROM EITHER SIDE OF SOLID CONCRETE WALL.
4. FILL,VOID OR CAVITY MATERIALS* - CAULK OR SEALANT - APPLIED TO FILL THE ANNULAR SPACE TO THE
MIN THICKNESS SHOWN IN THE FOLLOWING TABLE:
(A) BR = POLYETHYLENE BACKER ROD.
CF = CERAMIC FIBER BLANKET.
GF = GLASS FIBER INSULATION.
MW = MINERAL-WOOL BATT.
(B) CAULK INSTALLED FLUSH WITH TOP SURFACE OF FLOOR OR BOTH SURFACES OF WALL.
(C) CAULK INSTALLED FLUSH WITH BOTTOM SURFACE OF FLOOR OR ONE SURFACE OF SOLID (NON-
CONCRETE BLOCK) WALL.
3M COMPANY - CP 25WB+ CAULK OR FB-3000 WT SEALANT.
(NOTE: W RATING APPLIES ONLY WHEN FB-3000 WT SEALANT IS USED.)
*BEARING THE UL CLASSIFICATION MARKING
MAX PIPE DIAM
IN. (MM)
10 (254)
10 (254)
30 (762)
MAX ANNULAR
SPACE IN. (MM)
1 (25)
1 (25)
2-1/2 (64)
PACKING MATL
TYPE (a)
BR, CF, GF OR MW
CF OR MW
BR, CF, GF OR MW
MIN. CAULK THKNS
IN. (MM)
1/2 (13) (b)
1/2 (13) (c)
1 (25) (b)
System No. C-AJ-1001 June 15, 2005 F Rating - 3 Hr T Rating - 0 Hr
W Rating - Class I (See Item 4)
SECTION A-A
4 4 1
A
A
3/8" MAX[10mm]
MINERAL WOOL
(FIRMLY
PACKED)
CONDUIT, TYP
FLOOR
SLAB,
TYP.
FIRE STOP SEALANT
INTEGRAL
GALVANIZED LIPPED
STEAL MOUNTING
CHANNEL, TYP.
STEEL
EXPANSION
ANCHOR, TYP.
SPRING NUT,
TYP
CONDUIT COMPRESSION
FITTING, TYP.
JUNCTION BOX
(SIZE AS
REQUIRED)
SPRING NUT
CONDUIT FITTING
JUNCTION BOX
(SIZE AS
REQUIRED)
INTEGRAL GALVANIZED
LIPPED STEEL
MOUNTING CHANNEL
JUNCTION BOX, TYP
(SIZE AS REQUIRED)
BEAM
CLAMP,
TYP.
CONDUIT
TRAPEZE PER
SD260533-03, TYP. CONDUIT,
TYP.
STEEL
EXPANSION
ANCHOR
STRUCTURAL MEMBER
(BEAM , JOIST, ETC.), TYP.
SEISMIC OR
EXPANSION
JOINT. FIELD
VERIFY
ACTUAL
CONDITIONS &
LOCATIONS.
FLOOR OR ROOF
STRUCTURE. FIELD VERIFY
ACTUAL CONDITIONS, TYP.
PROVIDE 127MM (5") OF SLACK AT
MIDPOINT BETWEEN TWO END OF
FLEXIBLE GALVANIZED STEEL CONDUIT.
PROVIDE GREEN INSULATED COPPER
EQUIPMENT GROUNDING CONDUCTOR
WITH FLEXIBLE CONDUIT.
914mm
(3'-0") MAX
PROVIDE EXTRA CABLE TO
MAKE COMPLETE LOOP
AROUND BOX PERIMETER
GENERAL NOTE:
1. DETAIL IS APPLICABLE
ONLY FOR CONDUITS
SMALLER THAN 76MM (3").
STEP 1. FILE STRUCTURE CONNECTION AREA (3 IN. X 3. IN.
MIN) TO BARE SHINY METAL AND CLEAN.
GENERAL NOTES:
A. ALL CABLES AND WELDS SHALL BE MINIMUM 3 INCHES APART.
B. STANDARD WELD CARTRIDGES SHALL BE USED FOR STEEL SURFACES.
FOR DIP USE XF-19 WELD CARTRIDGES.
STEP 2. STRIP INSULATION FROM WIRE. ATTACH SLEEVE
(REQUIRED ON NO.4 AWG WIRE AND SMALLER).
STEP 3. HOLD MOLD FIRMLY WITH OPENING AWAY FROM
OPERATOR AND IGNITE WITH FLINT GUN.
STEP 4. REMOVE SLAG FROM CONNECTION AND PEEN
WELD FOR SOUNDNESS.
STEP 5. COVER CONNECTION AND EXPOSED STRUCTURE
SURFACE WITH AN EPOXY COATING.
HANDLE GRAPHITE COVER
STARTING POWDER
METAL WELDING POWDER
GRAPHITE MOLD
WIRE
PIPE WALL
METAL DISC
30° MAX.
FINISHED GRADE
GROUND ROD SHALL NOT BE ANGLED
MORE THAN 30° FROM VERTICAL.
ANGLE AWAY FROM SHELTER OR PAD
WHERE POSSIBLE.
3/4" DIAMETER COPPER CLAD
STEEL GROUND ROD 10' LONG.
AT LEAST 8' OF GROUND ROD IN
CONTACT WITH SOIL
GEC
ECLEUL
NO SLAG OR
DEFORMITIES
ALLOWED
EXOTHERMIC WELD
(THERMOWELD OR
EQUIVALENT). PARALLEL,
NO T-WELDS ALLOWED.
EXTERIOR GROUND RING,
2 AWG SOLID, BARE,
TINNED COPPER
GROUNDING CONDUCTOR
MINIMUM BENDING RADIUS
45 DEGREES, TYPICAL
JUMPER, 2 AWG SOLID,
BARE, TINNED COPPER
GROUNDING CONDUCTOR
BROWN
RED
BLUE
EMERGENCY
PANEL
WALL
SWITCH
GTD
BLACK 120V
OR ORANGE
277V (CAP
UNUSED LEAD)
VOLTAGE
SENSING
AC
BALLAST
OR
DRIVER
LAMP LEADS
NOT SHOWN
BLACK
WHITE
WHITE
WHITE/RED
WHITE/BLACK
NORMAL
PANEL
NORMAL
POWER
GENERATOR
ATS
G
NEUTRAL BUS
FOR NORMAL
PANEL
NEUTRAL BUS
FOR EMERGENCY
PANEL
AIR TERMINAL
GENERAL NOTES:
A. SEE PLATE E-001 FOR LEGEND.
B. ALL SPLICES BELOW GRADE SHALL BE THE EXOTHERMIC
WELD TYPE.
C. AIR TERMINALS SHALL EXTEND NO LESS THAN 24 INCHES
ABOVE THE ROOF.
D. ALL METAL EQUIPMENT ON THE ROOF SHALL BE BONDED
TO THE LIGHTNING PROTECTION SYSTEM.
E. THRU ROOF FLASHING SHALL BE COPPER WITH 8 INCH
ROUND BASE AND VERTICAL TUBE WITH NEOPRENE SEAL.
FLASHING SHALL BE THE PRODUCT OF THE
MANUFACTURER OF THE LIGHTNING PROTECTION SYSTEM.
A MEMBRANE FLASHING SHALL BE PROVIDED OVER THE
THRU ROOF FLASHING.
MAIN CONDUCTOR
CLIP CABLE SUPPORT
SEALING WASHER
(M
IN
RIGID STEEL CONDUIT
PVC CONDUIT
PVC CONDUIT
ADAPTER
COUPLING
FINISHED GRADE
VANDAL RESISTANT LIGHT
BOLLARD PER LIGHT
FIXTURE SCHEDULE
GALVANIZED ANCHOR BOLTS &
HEX NUTS. PROVIDE LEVELING
SHIMS OR HEX NUTS.
CONCRETE BASE &
REINFORCING
STEEL SEE NOTE
BELOW.
UNDISTURBED SOIL
OR SELECT BACKFILL
COMPACTED, SEE
NOTE BELOW.
GENERAL NOTES:
1. BACKFILL, CONCRETE, REINFORCING STEEL, AND ANCHOR BOLTS ARE
SHOWN FOR REFERENCE ONLY. STRUCTURAL DESIGN IS SHOWN ON
STRUCTURAL DRAWINGS.
2. REFER TO SPECIFICATION SECTION 26 56 00 FOR MOUNTING AND
LEVELING REQUIREMENTS.
[7 M
M
M
IN
[6 M
M
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:0
:3
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
E-501
ELECTRICAL DETAILS
22 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
Scale: No Scale
SERVICE GROUNDING DETAIL
Scale: No Scale
UL PENETRATION DETAIL C-AJ-1001
Scale: No Scale
FLOOR SLAB PENETRATION DETAIL
Scale: No Scale
CONDUIT EXPANSION JOINT CROSSING - FLEXIBLE
CONDUIT
Scale: No Scale
EXOTHERMIC WELD - WIRE TO PIPE
Scale: No Scale
GROUND ROD DETAIL
Scale: No Scale
GROUNDING MECHANICAL
BOND
Scale: No Scale
EXOTHERMIC WELD - WIRE TO WIRE
Scale: No Scale
EMERGENCY LIGHTING CONTROL (GENERATOR TRANSFER
DEVICE)
Scale: No Scale
LIGHTNING PROTECTION AIR TERMINAL
1 1
Scale: No Scale
BOLLARD BASE DETAIL
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
EXISTING PANEL
'EECR1B'
120/208V, 3PH, 4W
100A MCB
ELEC C1-117
FROM EXISTING
PANEL 'EECR1A'
480/277V, 3PH, 4W
125A MLO
EXISTING 30
KVA
480-208Y/120V, 3PH DRY TYPE
TRANSFORMER
'EECR1B'
EXISTING PANEL
'EELS1'
120/208V, 3PH, 4W
125A MLO
ELEC C1-117
FROM EXISTING
LIFE SAFETY
BRANCH
NEW PANEL 'LP-1'
120/208V, 3PH, 4W
200A MCB
ELEC C1-118
NEW PANEL 'LP-2'
120/208V, 3PH, 4W
100A MCB
ELEC C1-118
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
4-4/0 AWG,
1-4 AWG EG,
IN 2 1/2" C.
NEW PANEL 'A'
120/208V, 3PH, 4W
100A MCB
TR C1-100A
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
NEW PANEL 'B'
120/208V, 3PH, 4W
100A MCB
TR C1-100A
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
NEW PANEL 'LP-3'
120/208V, 3PH, 4W
100A MCB
ELEC C1-118SUPPLEMENTAL
GROUND, BONDED TO
NEW ADDITION STEEL
AND NEW DRIVEN
GROUND ROD
4 AWG GEC
NEW PANEL
'EELS1A'
120/208V, 3PH, 4W
100A MCB
ELEC C1-118
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
NEW 15 KVA
480-208Y/120V, 3PH DRY TYPE
TRANSFORMER
'EELS1T'
WALL MOUNTED
ELEC C1-118
4-10 AWG,
1-10 AWG EG,
IN 3/4" C.
EXISTING PANEL 'MP-1'
208/120V, 3PH, 4W 1000A
SQUARE D I-LINE TYPE HCR-U
BASEMENT ROOF
MECHANICAL ROOM
100A
200AF
200AT
200A
100A100A100A 100A
100A 100A
NORMAL BRANCH CRITICAL BRANCH
100A
100A
100A
30A
LIFE SAFETY BRANCH
PROVIDE NEW BREAKER
IN EXISTING PANEL
FROM EXISTING
EXISTING PANEL
'SLP2'
277/480V, 3PH, 4W
125A MLO
SQUARE D NQOD
ELECTRICAL
A2-119
NEW PANEL
'SLP2A'
277/480V, 3PH, 4W
100A MCB
SECOND FLOOR
MECHANICAL
ROOF
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
NEW 30 KVA
480-208Y/120V, 3PH
DRY TYPE
TRANSFORMER
'SLP2T'
SECOND FLOOR
MECHANICAL ROOF
NEW PANEL 'SLP2B'
120/208V, 3PH, 4W
100A MCB
SECOND FLOOR
MECHANICAL ROOF
4-3 AWG,
1-8 AWG EG,
IN 1 1/4" C.
4-8 AWG,
1-10 AWG EG,
IN 3/4" C.
100A
100A
50A
100A
CRITICAL BRANCH
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/1
/2
:0
:3
P
M C
U s e rs
\a m a s o n
\D o c u m e n ts \E
-0
-W ilk e s B a rr e M e n ta l H e a lt h a m a s o n a c g
-p a .c o m
.r v t
E-601
ELECTRICAL SCHEDULES AND SINGLE
LINE DIAGRAMS
23 26KLC
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
JKM
GENERAL NOTES:
A. MANUFACTURER AND CATALOG NUMBERS SHOWN ARE FOR BASIS OF DESIGN, DESCRIPTIVE AND QUALITY STANDARDS ONLY, NOT TO BE USED FOR ORDERING WITHOUT VERIFICATION AND APPROVAL. CONTRACTOR TO PROVIDE PRODUCT OR EQUAL FOR APPROVAL BY OWNER, ARCHITECT AND ENGINEER. ENGINEER SHALL NOT BE RESPONSIBLE FOR MISMATCHED OR INACCURATE PART NUMBERS.
B. FOR ALL LED FIXTURES, THE FIXTURE SHALL BE CAPABLE OF SELF-RESETTING TO THE SWITCHED/CONTROLLED STATE DURING ANY FLUCTUATION IN POWER SUPPLY WHERE AUTOMATIC PROTECTIVE MEASURES DISABLE THE LED LAMPS. PROVIDE A LETTER OR STATEMENT FROM THE MANUFACTURER, OR OTHER ACCEPTABLE PROOF, THAT ALL LED FIXTURES, WITH OR WITHOUT BROWNOUT PROTECTION, SHALL RETURN TO THE SWITCHED/CONTROLLED STATE AUTOMATICALLY. PROVIDE STATEMENT WITH THE FIXTURE SUBMITTALS.
C. LIGHTING CONTROLS, INCLUDING CONTROL SCHEMATICS, DEVICES, SWITCHES, SENSORS AND GRAPHIC DISPLAYS/CONTROLLERS. THIS INFORMATION MUST BE SUBMITTED WITH THE LIGHT FIXTURE SHOP DRAWINGS, FOR
A COMPLETE REVIEW.
LUMINAIRE SCHEDULE
TYPE DESCRIPTION MOUNTING LAMP DRIVER VOLTAGE WATTS MANUFACTURER MODEL NUMBER
A1 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER
RECESSED
GRID
LED; 4,000 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 31 W LITHONIA 2BLT4 40L ADSM EZ1 LP835
A1E 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER; WITH GENERATOR TRANSFER DEVICE
RECESSED
GRID
LED; 4,000 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 31 W LITHONIA 2BLT4 40L ADSM EZ1 LP835 BGTD
A2 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER
RECESSED
GRID
LED; 6,000 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 48 W LITHONIA 2BLT4 60L ADSM EZ1 LP835
A2E 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER WITH GENERATOR TRANSFER DEVICE
RECESSED
GRID
LED; 6,000 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 48 W LITHONIA 2BLT4 60L ADSM EZ1 LP835 BGTD
A3 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER
RECESSED
GRID
LED; 7,300 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 59 W LITHONIA 2BLT4 72L ADSM EZ1 LP835
A3F 2' X 4' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER
RECESSED
FLANGE
LED; 7,300 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% DRIVER
MULTI-VOLT 59 W LITHONIA 2BLT4 72L ADSM EZ1 LP835
B1 2' X 2' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER
RECESSED
GRID
LED; 3,330 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% LED
DRIVER
MULTI-VOLT 27 W LITHONIA 2BLT2 33L ADSM EZ1 LP835
B1E 2' X 2' ARCHITECTURAL TROFFER; WITH CURVED, SMOOTH CENTER
DIFFUSER WITH GENERATOR TRANSFER DEVICE
RECESSED
GRID
LED; 3,330 LUMENS;
80 CRI; 3500K
0-10V DIMMABLE
TO 1% LED
DRIVER
MULTI-VOLT 27 W LITHONIA 2BLT2 33L ADSM EZ1 LP835 BGTD
C1 4' LINEAR LED STRIPLIGHT WITH FROSTED LENS CHAIN
SUSPEND
LED; 4,585 LUMENS;
80 CRI; 4000K
ELECTRONIC LED
DRIVER
MULTI-VOLT 34 W LITHONIA ZL1N L48 5000LM FST MVOLT 40K 80CRI
D1 6" DIAMETER DIMMABLE LED WIDE DISTRIBUTION DOWNLIGHT RECESSED
FLANGE OR
GRID
LED; 2,000 LUMENS;
3500K; 80 CRI
0-10V DIMMABLE
TO 10% LED
DRIVER
MULTI-VOLT 20 W GOTHAM EVO6 35/20 AR MWD LD MVOLT GZ10
E1 CONTEMPORARY LED SINGLE FACED EXIT SIGN WITH BLACK
POWDER PAINT ALUMINUM HOUSING, BRUSHED ALUMINUM FACE,
RED LETTERS, AND CHEVRON ARROWS AS SHOWN ON PLANS.
UNIVERSAL LED RED --- MULTI-VOLT 5 W LITHONIA LES 1 R 120/277
E2 CONTEMPORARY LED DOUBLE FACED EXIT SIGN WITH BLACK
POWDER PAINT ALUMINUM HOUSING, BRUSHED ALUMINUM FACE,
RED LETTERS, AND CHEVRON ARROWS AS SHOWN ON PLANS.
UNIVERSAL LED RED --- MULTI-VOLT 5 W LITHONIA LES 2 R 120/277
F1 6" DIAMETER DIMMABLE LED WET LOCATION SHOWER DOWNLIGHT RECESSED LED; 1,000 LUMENS;
3500K; 80 CRI
0-10V DIMMABLE
LED DRIVER
MULTI-VOLT 20 W GOTHAM EVO6SH 35/10 DFF SMO MVOLT EZ10
H1 25.5" VANITY; CURVED WHITE ACRYLIC DIFFUSER; NICKEL TONE
FINISH
SURFACE
WALL
LED; 1,500 LUMENS;
80 CRI; 3500K
ELECTRONIC LED
DRIVER
MULTI-VOLT 16 W BROWNLEE 5190-26-NT-H16-35K-BAC
J1 29" BULL NOSE VANITY; TWO APERTURES FOR UP/DOWN LIGHT;
BEHAVIORAL HEALTH RATED
SURFACE
WALL
LED; 4,500 LUMENS;
80 CRI; 3500K
ELECTRONIC LED
DRIVER
MULTI-VOLT 57 W KENALL WCBU 2 0/0 25L35K DIM1 DV SYM/G 1
K1 6" DIAMETER DIMMABLE LED MEDIUM DISTRIBUTION DOWNLIGHT;
CLEAR POLYCARBONATE LENS; BEHAVIORAL HEALTH RATED
RECESSED
FLANGE OR
GRID
LED; 850 LUMENS;
3500K; 80 CRI
0-10V DIMMABLE
TO 1% LED
DRIVER
MULTI-VOLT…