This document appears to be Attachment 3 - Drawings for the "Expand Mental Health Clinic Construction Wilkes Barre" federal contract opportunity, Solicitation Number 36C77624R0079_1. The project is a competitive Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside, requiring the contractor to provide all labor, project management, materials, tools, supplies, and equipment to complete the necessary work based on the drawings and specifications. The project location is the Wilkes-Barre VA Medical Center in Pennsylvania. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
4 5 4 5
4 5
CRAWL SPACE
A-316
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
14151617
A-312
4'-4"
COORDINATE W/ ARCH PLANS AND STRUCT DWGS
34'-6 1/2" VIF
A-311
C O
O R
W
A
R C
H A
N D
S T
R U
C T
D W
G S
/4
6'-3"
8'-2" VIF
A-402
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:5
:3
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-201
EXTERIOR ELEVATIONS
26 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/4" = 1'-0"
DEMO ELEVATION FROM LOW SIDE OF STONE VENEER RETAINING WALL
Scale: 1/4" = 1'-0"
DEMO ELEVATION AT STAIR WALL
1 DEMOLISH EXISTING CONCRETE STAIR, RAILS,
SUPPORTING WALLS, AND INFILL. EXISTING
RETAINING WALL FOOTING TO REMAIN.
2 DEMOLISH HANDRAIL, TYPICAL.
3 DEMOLISH EXISTING SIDEWALK, TYPICAL.
4 DEMOLISH TOP OF EXISTING STONE RETAINING
WALL TO EXTENTS SHOWN.
5 REMOVE EXISTING STONE CAP TO EXTENT SHOWN
AND REINSTALL PORTION AS NECCESARY
6 DEMOLISH RAILING, TYPICAL.
7 DEMOLISH EXISTING WINDOW.
8 EXISTING ROOF SLAB AND DECK TO BE REMOVED.
9 DEMOLISH PORTION OF WALL AS DIMENSIONED,
COMPLETE, TO 1'-0" BELOW FIRST FLOOR FFE.
COORDINATE W/ STRUCTURAL DWGS.
10 DEMOLISH EXISTING DOOR SYSTEM. EXISTING
LINTEL TO REMAIN.
11 DEMOLISH PORTION OF CRAWL SPACE SLAB AS
NECESSARY FOR NEW STRUCTURAL FOOTINGS.
SEE PLANS AND COORDINATE WITH STRUCTURAL
DWGS.
12 SAWCUT EXISTING CONCRETE EXTENSION TO BE
FLUSH WITH FACE OF EXISTING EXTERIOR BRICK
WALL. DEMOLITION EXTENTS TO BE 2" FROM
OUTSIDE FACE OF NEW INSULATED METAL PANEL
WALL.
13 DEMOLISH ASPHALT WALKWAY AND CONCRETE
SLAB BELOW.
14 DEMOLISH EXISTING EXTERIOR WALL TO EXTENTS
TO FINISH FLOOR. COORDINATE WITH PLANS,
SECTIONS AND VIF.
DocuSign Envelope ID: B5D2F642-20A9-468E-8580-A187C7F6F37C
SOL # 36C77624R0079 Project # 693-352 Expand Mental Health Clinic Construction-Wilkes-Barre, PA
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
A-302
A-302
S.1 S.4
LINE OF ADDITION
A-201
19'-5"
4'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"8'-0"7'-0" 8"
NEW T.O. STONE RETAINING
WALL
14'-8 1/4"
A-402
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
A-302
A-302
S.1 S.4
/2
/2
A-201
4"
NEW T.O. STONE RETAINING
WALL
14'-8 1/4"
A-402
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:5
:3
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-202
EXTERIOR ELEVATIONS
27 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
1 NEW OVERFLOW SCUPPERS AND DOWNSPOUTS
WITH NEW PRECAST CONCRETE SPLASH BLOCKS.
2 PART OF NEW MENTAL HEALTH ADDITION WITH 2"
THICK, PREFABRICATED INSULATED METAL PANEL
SYSTEM. BASIS OF DESIGN - CENTRIA FORMAWALL.
3 INSTALL NEW CHAINLINK FENCING FALL
PROTECTION. OFFSET 9" FROM EXISTING
RETAINING WALL, TERMINATE 12'-0" PAST
ADDITION.
4 INSULATED METAL PANEL MANUFACTURER'S
STANDARD END OF PANEL WALL TRIM.
5 EXISTING CONCRETE EYEBROW TO REMAIN.
6 SAWCUT EXISTING CONCRETE EYEBROW 2" AWAY
FROM FACE OF NEW INSULATED METAL PANEL
OUTSIDE FACE OF NEW EGRESS ENCLOSURE.
7 NEW PARAPET COPING AT MENTAL HEALTH
ADDITION.
8 MITERED CORNER, SEAL FRONT EDGE OF COPING
WATERTIGHT.
9 LINE OF APPROXIAMATE EXISTING GRADE.
10 REINSTALLED STONE COPING. METAL FLASHING AT
HORRIZONTAL JOINTS.
Scale: 1/4" = 1'-0"
SOUTH ELEVATION AT NEW MENTAL HEALTH ADDITION
Scale: 1/4" = 1'-0"
SOUTH ELEVATION AT NEW MENTAL HEALTH ADDITION (FENCE HIDDEN)
THIRD FLOOR
24' - 0 3/4"
16.3 15.7
A-312
_____2
A-313
_____ 2
A-311
14.8
V
IF
10'-5" 16'-0" 16'-0" 11'-0"
12'-0" 6'-0" 6'-0" 12'-0" 9'-0"
2C-1 2C-2
A-311
C2
17 18
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
FOURTH FLOOR
35' - 5 1/4"
14151617 15.116.3 15.7 14.615.916.6 14.8
7 8
A-203
C2
C-107
A-402
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:5
:4
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-203
EXTERIOR ELEVATIONS
28 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
1 NEW CONDUCTOR AND DOWNSPOUTS, WATER
DISCHARGED ONTO THE NEW MENTAL HEALTH
ADDITION ROOF. COLOR TO MATCH PANELS.
2 2" THICK, PREFABRICATED INSULATED METAL
PANEL SYSTEM, TYPICAL AT EW STAIR EXIT
CORRIDOR ABOVE MENTAL HEALTH ADDITION.
BASIS OF DESIGN - CENTRIA FORMAWALL. COLOR
TO MATCH EXISTING.
3 INSTALL NEW CHAINLINK FENCING FALL
PROTECTION. OFFSET 9" FROM EXISTING
RETAINING WALL, TERMINATE 12'-0" PAST
ADDITION.
4 EXPANSON JOINT TO PARAPET WALL ABOVE AND
OVERLAPPED BY COPING.
5 MENTAL HEALTH ADDITION WITH RUNNING BOND
BRICK VENEER, TYPICAL. COLOR TO MATCH
EXISTING.
6 THROUGH WALL FLASHING AND WEEPS ABOVE
ENTRY DOOR OPENING 24" O.C.
7 THROUGH WALL FLASHING AND WEEPS AT LOWER
WALL 24" O.C.
8 MASONRY CONTROL JOINT, TYP.
9 EXISTING RETAINING WALL AT DRIVEWAY AISLE TO
REMAIN.
10 EXISTING BUILDING BEYOND TO REMAIN.
12 EXTERIOR LIGHT, CENTERED OVER DOOR, MOUNT
AT 9'-0" AFF TO CENTER OF FIXTURE.
13 EXPANSION JOINT, SEE SPECS
14 EXISTING GUARDRAIL TO REMAIN, PROTECT AS
NOTED IN REFERENCE PHOTOS.
15 12"W X 24"D X 6" H PRECAST CONCRETE SPLASH
BLOCK.
16 ROOFING MEMBRANE.
17 START OF METAL PANEL.
18 BUILT UP ROOF CURB.
19 EXISTING BRICK PILASTER TO REMAIN.
20 COW TONGUE, SEE PLUMBING DRAWINGS.
21 COPING TO OVERLAP EXISTING DRIVE AISLE WALL
AND MENTAL HEALTH ADDITION PARAPET WALL.
EXPANSION JOINT ALONG CENTER OF COPING.
22 EXISTING CONCRETE OVERHANG EXTENSION TO
REMAIN.
23 SAWCUT EXSTING CONCRETE EYEBROW 2" AWAY
FROM FACE OF NEW INSULATED METAL PANEL
OUTSIDE FACE OF NEW EGRESS ENCLOSURE.
CAULK 2" GAP.
24 EXISTING CHAINLINK FENCE TO REMAIN.
25 SAWCUT EXISTING CONCRETE FLOOR AT
LIGHTWELL TO INSTALL NEW DRAIN AND DRAIN
LINE. PATCH AND REPAIR WITH NEW CONCRETE.
Scale: 1/4" = 1'-0"
STAIR EXIT CORRIDOR ELEVATION
Scale: 1/4" = 1'-0"
MENTAL HEALTH ADDITION ELEVATION
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
FOURTH FLOOR
35' - 5 1/4"
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
ROOF LEVEL
35' - 5 1/4"
E X
IS
T
IN
G
M E
T A
L P
A N
E L S
Y S
T E
M
M E
T A
L P
A N
E L S
Y S
T E
M
N E
W I
N S
U L
A T
E D
1'-6 1/2" 1'-9"
22 3
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
FOURTH FLOOR
35' - 5 1/4"
M E
T A
L P
A N
E L S
Y S
T E
M
N E
W I
N S
U L
A T
E D
E X
IS
T
IN
G
I N
S U
L A
T E
D M
E T
A L
P A
N E
L S
Y S
T E
M
EQ EQ
DELETE ALL WORK ASSOCIATED WITH THE
NEW SECOND FLOOR POLICE SUITE,
INCLUDING BUT NOT LIMITED TO ALL
ASSOCIATED DEMOLITION AND NEW
CONSTRUCTION.
DEDUCTIVE ALTERNATES:
Engineers Architects
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:5
:4
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-204
EXTERIOR ELEVATIONS
29 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/4" = 1'-0"
NORTH ELEVATION AT AHU ENCLOSURE
Scale: 1/4" = 1'-0"
WEST ELEVATION AT AHU ENCLOSURE
1 NEW METAL PANEL WALL BEYOND. MATCH
EXISTING COLOR. BASIS OF DESIGN: CENTRIA,
FORMAWALL SERIES, OR EQUAL COLOR TO
MATCH EXISTING.
2 VERTICAL METAL PANEL REVEALS TO ALIGN WITH
EXISTING REVEALS BELOW, TYPICAL.
3 VERTICAL METAL PANEL REVEALS TO ALIGN WITH
EDGE OF LOUVER.
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
S
A-302
A-302
U.4V.9
A-302
A-302
S.1S.4S.6T.5V.4
CORRIDOR
C-107
OFFICE/
CONSULT
C1-142
STAIR
EXIT
CORRIDOR
2C
A-316
A-313
134 135 136 137 138 139 140
LINE OF GROUT FLUME BEYOND. BETWEEN
EXISTING WALL AND NEW CMU BLOCK.
SLOPE @ 2% TO FLOOR LINE AT EAST WALL
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
GROUND FLOOR
-13' - 10 1/2"
A-302
A-302
U.4
A-302
A-302
V.1S.1 S.4
S.6
T.5
CORRIDOR
C-105
OFFICE/
CONSULT
C1-151
OFFICE/
CONSULT
C1-150
CORRIDOR
C-106
OFFICE/
CONSULT
C1-130
STAIR
TOILET
STAIR
TOWER
EXIT
2E
STAIR
EXIT
CORRIDOR
2C
OFFICE/
CONSULT
C1-144
INFILL EXISTING
WINDOW
INFILL EXISTING
WINDOW
A-601
A-315
A-503
SIM _____
A-503
SIM
V
IF
A-402
/2
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:0
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-301
BUILDING SECTIONS AT MENTAL
HEALTH ADDITION
30 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/4" = 1'-0"
BUILDING SECTION THROUGH MENTAL HEALTH ADDITION EXIT FACING SOUTH
Scale: 1/4" = 1'-0"
BUILDING SECTION THROUGH LIGHTWELL FACING NORTH
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
GROUND FLOOR
-13' - 10 1/2"
131417
A-301
A-301
15.116.3
A-301
A-301
A-314
1_____ A-314
2 15.7 14.615.9
OFFICE/
CONSULT
C1-142
OFFICE/
CONSULT
C1-143
OFFICE/
CONSULT
C1-144
OFFICE/
CONSULT
C1-145
OFFICE/
CONSULT
C1-146
2C
STAIR EXIT CORRIDOR
C-102
CORRIDOR
16.6
A-312
STOR
C1-141
A-313
_____ 2
A-311
14.8
CRAWL
SPACE
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
GROUND FLOOR
-13' - 10 1/2"
A-301
A-301
15.116.3
A-301
A-301
A-316
5 15.7 14.615.9
CORRIDOR
C-102
CORRIDOR
C-106
CORRIDOR
C-107
OFFICE/
CONSULT
C1-137
16.6
A-315
152142 150 149B
A-312
_____2
A-313
_____ 2
A-311
STORAGE
CG-25
14.8
"1
"4
TURNED UP
ROOFING
MEMBRANE
BEYOND
A-311
A-402
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:0
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-302
BUILDING SECTIONS AT MENTAL
HEALTH ADDITION
31 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/4" = 1'-0"
BUILDING SECTION THROUGH STAIR EXIT ENCLOSURE FACING WEST
Scale: 1/4" = 1'-0"
BUILDING SECTION THROUGH STONE RETAINING WALL FACING WEST
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
B
A-303
A-303
A-317
4A.2 B.3
AHU
ENCLOSURE
C2-211A
OFFICE
A1-09A
EXAM
A1-08
1'-6"
EXISTING MECHANICAL
ROOM LOUVER TO
REMAIN
EXISTING RIBBON
WINDOW TO REMAIN
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
ABC
A-317
A-317
A-303
A-303
A.2B.3
211A
AHU
ENCLOSURE
C2-211A
EXISTING METAL PANEL
WALL TO REMAIN
EXISTING CONCRETE
OVERHANG BEYOND
OFFICE
A1-09A
EXAM
A1-08
EXAM
A1-07
EXISTING ROOF, ADD SPRAY ON
FIREPROOFING @ DECK BELOW TO
ACHIEVE 2 HR FIRE SEPARATION AT
TAPERED FLOOR.
STEP AT DOORWAY
INTO AHU ENCLOSURE
ROOM
1/4" / 12"
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
10 11 12 13 14
A-303
A-303
_____3
A-303
A-303
A-317
9.3 10.6
AHU
ENCLOSURE
C2-211A
TRAINING
ROOM
C2-211
CONF.
ROOM
A1-10
CONF.
ROOM
A1-09
OFFICE
A1-09A
1'-6"
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:1
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-303
BUILDING SECTIONS AT AHU
ENCLOSURE
32 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 1/4" = 1'-0"
TRANSVERSE SECTION AT AHU ENCLOSURE
Scale: 1/4" = 1'-0"
TRANSVERSE SECTION FACING POLICE SUITE
Scale: 1/4" = 1'-0"
LONGITUDINAL SECTION AT AHU ENCLOSURE
1 1
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
S.1S.4
STAIR
EXIT
CORRIDOR
2C
STAIR
TOWER
EXIT
2E
OFFICE/
CONSULT
C1-144
STAIR
5/8" GYPSUM WALL BOARD
BATT INSULATION
NEW 6" CMU GLAZED FACE TO
MATCH EXISTING AND TO
ALIGN WITH EDGE OF OPENING
BEYOND
CONCRETE SLAB ON 1 1/2"
METAL DECK, OVER SLOPED
STRUCTURAL STEEL FRAMING
90MIN METAL ROOF DECK ON 2HR
STRUCTURAL STEEL FRAMING, SEE
STRUCUTRAL DRAWINGS,
FIREPROOF AS REQUIRED
EXISTING EXTERIOR WALL
BRICK VENEER TO REMAIN
CEILING AS SCHEDULED
CEILING AS SCHEDULED
NEW GROUT FILLED 4" CMU
BLOCK WALL TO INFILL
EXISTING DOOR OPENING
ALIGN
2 LAYERS OF 5/8", TYPE X,
GYPSUM WALL BOARD
1 1/2" METAL DECK, OVER
SLOPED STRUCTURAL STEEL
FRAMING, WITH SPRAY ON FIRE
PROOFING SEE STRUCT DWGS
CEILING AS
SCHEDULED
FIREPROOFING @ STEEL
FRAMING, TYPICAL
TO STEEL @ G/L S.1
25'-2"
TO STEEL @ G/L S.4
25'-0 1/2"
GYPSUM BULKHEAD
3/4" CONT FIRE SEALANT ALONG
TOP OF FIRE RATED PARTITIONS,
TYPICAL
A-503
EXISTING GLAZED
TILE TO REMAIN
2" EJ COVER, AND 2 HR
FIRE RATED EXPANSION
JOINT ASSEMBLY, BEYOND
TO STEEL TUBE
26'-9 1/2"
EXTEND FIRE PROOFING AS
REQUIRED TO MAINTAIN RATING
OF FIRE RATED PARTITIONS, TYP
2" EJ COVER
SCHEDULED BASE
2 HR FIRE RATED EJ
ASSEMBLY, BEYOND
FIREPROOFING @ STEEL
FRAMING, TYPICAL
CONT VAPOR BARRIER
SEAL PERIMETER OF VAPOR
BARRIER ALONG TOP EDGE OF
NEW SLAB ON GRADE AND EXIST
FOUNDATION WALL, USING TACK
TAPE OR MASTIC
AGGREGATE BASE
SEE STRUCT DWGS
1/2" JOINT FILLER
CONC SLAB ON GRADE
SEE STRUCT DWGS
1/2" BACKER ROD AND SEALANT
2" PERIMETER INSUL
A-503
6" CFMF STUD FRAMING6" CFMF STUD FRAMING
FIREPROOFING @ STEEL
FRAMING, TYPICAL
A-503
CEILING AS SCHEDULED
PREFABRICATED INSULATED METAL
PANEL SYSTEM. BASIS OF DESIGN -
CENTRIA FORMAWALL, 2" THICK,
COLOR TO MATCH EXISTING,
TYPICAL ALL METAL PANEL
LIQUID APPLIED VAPOR RETARDER
R19 THERMAL BATT INSULATION
BASIS OF DESIGN CENTRIA
BRAKE METAL COPING OR
EQUAL, 24 GA.
2 LAYERS OF 5/8" FIBERGLASS FACED,
TYPE X, EXTERIOR SHEATHING
6"X3" TOP TRACK. ATTACH TO
BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. PROVIDE
1" GAP BETWEEN TOP OF STUDS
AND TRACK. DO NOT ATTACH
STUDS OR GYPSUM TO TOP TRACK
2 1/2" RUNNER, ATTACH TO TOP
SIDE OF BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. ALIGN WITH
FACE OF STUDS BELOW
STEEL TUBE AT TOP OF
PARAPET, SEE STRUCTURAL 90 MIN FIRE RATED EXP JOINT
ASSEMBLY ABOVE NEW
OPENING, OVERLAP TO 90
MIN RATED ROOF ASSEMBLY
AND TO FIRE RATED JOINT
ASSEMBLY BEYOND, TO
ENSURE CONTINUITY OF 2 HR
RATED ENCLOSURE, TYP.
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
S
DEMOLISH WINDOW SYSTEM
DEMOLISH EXISTING
CEILING SYSTEM
SAW CUT EXISTING
CONCRETE EXTENSION TO BE
FLUSH WITH EXTERIOR FACE
OF EXISTING FACADE.
DEMOLITION EXTENTS TO BE
2" FROM OUTSIDE FACE OF
NEW INSULATED METAL
PANEL WALL.
SAW CUT CONCRETE CURB
TO BE FLUSH WITH
SECOND FLOOR AND
PREPARE FOR NEW
FLOORING FINISH
DEMOLISH METAL
COVER
DEMOLISH COMPLETE
METAL CANOPY SYSTEM
EXISTING GLAZED
TILE TO REMAIN
DEMOLISH TILE HEAD
REMOVE MINIMUM TOP (3)
ROWS OF BRICK BELOW
SECOND FLOOR, CLEAN AND
PREPARE FOR NEW WORK
DEMOLISH EXTERIOR LIGHT
DEMOLISH CONCRETE
WALL IN IT'S ENTIRETY TO
1'-0" BELOW FIRST FLOOR
FFE. SEE STRUCTURAL
DWGS
DEMOLISH CONCRETE
SIDEWALKS
DEMOLISH EXISTING
DOOR AND FRAME
DEMOLISH GUARDRAIL
M
IN
IM
U
M
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
S.4S.6
6" CFMF STUD FRAMING
TO STEEL TUBE
26'-8 3/4"
TO STEEL @ G/L S.4
25'-0 1/2"
OFFICE/
CONSULT
C1-143
CEILING AS SCHEDULED
STAIR
EXIT
CORRIDOR
2C
A-503
SCHEDULED BASE
CONT VAPOR BARRIER
AGGREGATE BASE
SEE STRUCT DWGS
CONC SLAB ON GRADE
SEE STRUCT DWGS
A-503
FIREPROOFING @ STEEL
FRAMING, TYPICAL
CEILING AS SCHEDULED
2 LAYERS OF 5/8", TYPE X,
GYPSUM WALL BOARD
PREFABRICATED INSULATED METAL
PANEL SYSTEM. BASIS OF DESIGN -
CENTRIA FORMAWALL, 2" THICK
LIQUID APPLIED VAPOR
RETARDER
R19 THERMAL BATT INSULATION
BASIS OF DESIGN CENTRIA
BRAKE METAL COPING OR EQUAL
2 LAYERS OF 5/8" FIBERGLASS FACED,
TYPE X, EXTERIOR SHEATHING
6"X3" TOP TRACK. ATTACH TO
BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. PROVIDE
1" GAP BETWEEN TOP OF STUDS
AND TRACK. DO NOT ATTACH
STUDS OR GYPSUM TO TOP TRACK
2 1/2" RUNNER, ATTACH TO TOP
SIDE OF BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. ALIGN WITH
FACE OF STUDS BELOW
MANUFACTURER'S STANDARD
BASE TRIM
/4
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:2
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-311
WALL SECTIONS
33 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH NEW EAST STAIR TOWER EXIT
Scale: 3/4" = 1'-0"
DEMO WALL SECTION AT STAIR TOWER EXIT
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH NEW EAST STAIR TOWER EXIT SCUPPER
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
S
CRAWL SPACE
C O
O R
D W
S
T R
U C
T D
W G
S
DEMOLISH SIDEWALK TOPPING AND
CONCRETE STRUCTURAL FLOOR.
SAWCUT FLUSH W/ EXTERIOR FACE
OF EXISTING BRICK
DEMOLISH TOP PORTION OF
CONCRETE RETAINING WALL TO
FACE OF EXISTING STONE VENEER
WALL BEYOND
DEMOLISH PORTION OF EXISTING
CONCRETE SLAB, SEE PLAN FOR
EXTENTS
EXCAVATE DIRT TO PREPARE FOR
NEW INFILL AND CONCRETE SLAB
BENCH EXCAVATION FOR SAFETY
DEMOLISH STONE CAP
DEMOLISH RAILING
DEMOLISH PORTION OF EXISTING
STONE VENEER WALL BEYOND
DEMOLISH CAST IN PLACE
CONCRETE STAIRS
SAW CUT EXISTING CONCRETE
FLUSH W/ EXTERIOR FACE OF
EXISTING BRICK AND DEMOLISH
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
S.1S.4
S.6
A-503
CRAWL SPACE
STAIR
EXIT
CORRIDOR
2C
FAMILY
CONSULT
C1-140
SCUPPER BEYOND
NEW CRAWL SPACE CONCRETE
FLOOR TO ALIGN W/ EXISTING
CONTINUOUS VAPOR BARRIER
TO STEEL @ G/L S.4
25'-0 1/2"
TO STEEL TUBE
26'-9 1/2"
EXISTING STOREFRONT
TO REMAIN PROTECT AS
REQ'D
TO STEEL @ G/L S.1
25'-2"
A-503
SIM
EXISTING BRICK VENEER AND
CMU BACK-UP TO REMAIN
PROTECT AS REQ'D
EXISTING SLOPED CONCRETE
WALL TO REMAIN
SEAL PERIMETER OF VAPOR
BARRIER ALONG TOP EDGE OF
NEW SLAB ON GRADE AND EXIST
FOUNDATION WALL, USING TACK
TAPE OR MASTIC
COMPACTED GRAVEL
SEE STRUCT DWGS
CONC SLAB ON GRADE
SEE STRUCT DWGS
3" PERIMETER INSUL
2'-0" MINIMUM
BELOW FLOOR INSULATION
1/2" JOINT FILLER
1/2" BACKER ROD AND SEALANT
COMPACTED ENGINEERED FILL
90MIN METAL ROOF DECK ON 2HR
STRUCTURAL STEEL FRAMING, SEE
STRUCUTRAL DRAWINGS,
FIREPROOF AS REQUIRED
CEILING AS SCHEDULED
2 LAYERS OF 5/8", TYPE X,
GYPSUM WALL BOARD
FIREPROOFING @ STEEL
FRAMING, TYPICAL
3/4" CONT FIRE SEALANT ALONG
TOP OF FIRE RATED PARTITIONS,
TYPICAL
EXTEND FIRE PROOFING AS
REQUIRED TO MAINTAIN RATING
OF FIRE RATED PARTITIONS, TYP
6" CFMF STUD FRAMING6" CFMF STUD FRAMING
1 1/2" METAL DECK, OVER
SLOPED STRUCTURAL
STEEL FRAMING, WITH
SPRAY ON FIRE PROOFING
SEE STRUCT DWGS
FIREPROOFING @ STEEL
FRAMING, TYPICAL
CONTINUOUS LIQUID APPLIED
VAPOR RETARDER OVERLAP
TO VAPOR BARRIER BELOW
2" RIGID INSUL
GROUT FLUME, SLOPE
SOUTH AT 1/4" PER FOOT.
FULL HEIGHT EXISTING SLOPED
CONCRETE WALL TO REMAIN PLAN
SOUTH OF COLUMN LINE 16.6
8X8X16 CMU BLOCK WALL,
SEE STRUCTURAL
DRAWINGS FOR
REINFORCING
EXISTING CAMPUS-WIDE
JUNCTION BOX (BEYOND) TO
REMAIN. DO NOT MOVE, OR
DAMAGE. PROTECT
THROUGHOUT ALL
CONSTRUCTION PHASES.
CEILING AS SCHEDULED
PREFABRICATED INSULATED METAL
PANEL SYSTEM. BASIS OF DESIGN -
CENTRIA FORMAWALL, 2" THICK,
COLOR TO MATCH EXISTING,
TYPICAL ALL METAL PANEL
LIQUID APPLIED VAPOR RETARDER
R19 THERMAL BATT INSULATION
BASIS OF DESIGN CENTRIA
BRAKE METAL COPING OR
EQUAL, 24 GA.
2 LAYERS OF 5/8" FIBERGLASS FACED,
TYPE X, EXTERIOR SHEATHING
6"X3" TOP TRACK. ATTACH TO
BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. PROVIDE
1" GAP BETWEEN TOP OF STUDS
AND TRACK. DO NOT ATTACH
STUDS OR GYPSUM TO TOP TRACK
2 1/2" RUNNER, ATTACH TO TOP
SIDE OF BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. ALIGN WITH
FACE OF STUDS BELOW
STEEL TUBE AT TOP OF
PARAPET, SEE STRUCTURAL
A-503
METAL COPING OVER CMU
PARAPET BEYOND
METAL COPING OVER BUILT
UP CURB BEYOND
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:2
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-312
WALL SECTIONS
34 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
DEMO WALL SECTION AT CRAWL SPACE
Scale: 3/4" = 1'-0"
WALL SECTION AT CRAWL SPACE
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
S.1S.4S.6
NEW 8" CMU BLOCK WALL
ALIGN
CEILING AS SCHEDULED
NEW STEEL COLUMN,
SEE STRUCTURAL DWGS
5/8" GYPSUM WALL BOARD
THERMAL BATT INSULATION
CRAWL
SPACE
TO STEEL @ G/L S.4
25'-0 1/2"
2 HR FIRE RATED
EXP JT ASSEMBLY
STAIR
EXIT
CORRIDOR
2C
A-503
SIM
OFFICE/
CONSULT
C1-142
2 HR RATED WINDOW SYSTEM.
BASIS OF DESIGN, CENTRIA
FORMAVUE HIGH PERFORMANCE
INTEGRATED WINDOW SYSTEM
GWB HEAD, JAMB AND
SILL, TYPICAL
CONCRETE SLAB ON SLOPED
METAL DECK, SEE STRUCTURAL
TO STEEL @ G/L S.1
25'-2"
TO FOOTINGS
SEE STRUCT DWGS
90MIN METAL ROOF DECK ON 2HR
STRUCTURAL STEEL FRAMING, SEE
STRUCUTRAL DRAWINGS,
FIREPROOF AS REQUIRED
CEILING AS SCHEDULED
2 LAYERS OF 5/8", TYPE X,
GYPSUM WALL BOARD
FIREPROOFING @ STEEL
FRAMING, TYPICAL
3/4" CONT FIRE SEALANT ALONG
TOP OF FIRE RATED PARTITIONS,
TYPICAL
EXTEND FIRE PROOFING AS
REQUIRED TO MAINTAIN RATING
OF FIRE RATED PARTITIONS, TYP
6" CFMF STUD FRAMING
1 1/2" METAL DECK, OVER
SLOPED STRUCTURAL STEEL
FRAMING, WITH SPRAY ON FIRE
PROOFING SEE STRUCT DWGS
CEILING AS SCHEDULED
PREFORMED CANT
PREFABRICATED INSULATED METAL
PANEL SYSTEM. BASIS OF DESIGN -
CENTRIA FORMAWALL, 2" THICK,
COLOR TO MATCH EXISTING,
TYPICAL ALL METAL PANEL
3/4" FR/PT PLYWOOD
TERMINATION BAR AND FLASHING
LIQUID APPLIED VAPOR RETARDER
R19 THERMAL BATT INSULATION
BASIS OF DESIGN CENTRIA
BRAKE METAL COPING OR
EQUAL, 24 GA.
2 PLY ADHERED SBS MEMBRANE ON
5/8" GYPSUM COVER BOARD OVER
R-33 POLY-ISO INSULATION
2 LAYERS OF 5/8" FIBERGLASS FACED,
TYPE X, EXTERIOR SHEATHING
6"X3" TOP TRACK. ATTACH TO
BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. PROVIDE
1" GAP BETWEEN TOP OF STUDS
AND TRACK. DO NOT ATTACH
STUDS OR GYPSUM TO TOP TRACK
EXTRUDED SILL TRIM
2 1/2" RUNNER, ATTACH TO TOP
SIDE OF BOTTOM FLANGE OF FIRE
PROOFED STEEL BEAM. ALIGN WITH
FACE OF STUDS BELOW
EXTEND SBS ROOFING UP PLYWOOD
PANEL & UNDER SILL TRIM. SECURE
W/ CONTINUOUS TERMINATION BAR
DOWNSPOUT AND SPLASH
BLOCK BEYOND
STEEL TUBE AT TOP OF
PARAPET, SEE STRUCTURAL
11 1/2"
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
A-302
A-302
S.1S.4
STAIR
EXIT
CORRIDOR
2C
CEILING AS SCHEDULED
6" CFMF STUD FRAMING
2 LAYERS 5/8" TYPE X
GYPSUM WALL BOARD
CRAWL
SPACE
A-503
SIM
SLAB ON GRADE TO ALIGN
WITH SECOND FLOOR
ELEVATION AT DOOR AND
EXTEND 5'-0" MIN EAST
FIREPROOF STEEL BEAM
AND ANCHOR TO EXISTING
CONCRETE BEAM /
RETAINING WALL, SEE
STRUCTURAL DRAWINGSINFILL AGGREGATE
BASE AS REQUIRED
EXISTING DRIVE AISLE
TO REMAIN
C2
SCUPPER BEYOND
TO STEEL @ G/L S.4
25'-0 1/2"
TO STEEL TUBE
26'-9 1/2"
DOOR THRESHOLD
BASIS OF DESIGN:
PEMKO 278_FG SERIES
BASIS OF DESIGN CENTRIA
BRAKE METAL COPING OR
EQUAL, 24 GA.
STEEL TUBE, SEE
STRUCTURAL
#4 REBAR DOWELS @ 12" OC,
6" MIN EMBEDDING EACH SIDE
90MIN METAL ROOF DECK ON 2HR
STRUCTURAL STEEL FRAMING, SEE
STRUCUTRAL DRAWINGS,
FIREPROOF AS REQUIRED
FIREPROOFING @ STEEL
FRAMING, TYPICAL
3/4" CONT FIRE SEALANT ALONG
TOP OF FIRE RATED PARTITIONS,
TYPICAL
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:2
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-313
WALL SECTIONS
35 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH CRAWL SPACE
Scale: 3/4" = 1'-0"
WALL SECTION AT STAIR EXIT ENCLOSURE DISCHARGE
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
1415.1 14.6
CEILING AS SCHEDULED
CONCRETE SLAB ON DECK
2 PLY ADHERED SBS
MEMBRANE ON 5/8"
GYPSUM COVER BOARD
OVER MIN R-33 POLY ISO
RIGID INSULATION
90MIN METAL ROOF DECK ON 2HR
STRUCTURAL STEEL FRAMING,
SEE STRUCUTRAL DRAWINGS,
FIREPROOF AS REQUIRED
CEILING AS SCHEDULED
WALL TYPE Ssb3
OFFICE/
CONSULT
C1-144
OFFICE/
CONSULT
C1-145
STAIR
EXIT
CORRIDOR
2C
EXISTING EXTERIOR WALL
STRUCTURE TO REMAIN
5/8" GWB ON 3 5/8" METAL
STUD FRAMING
DUCT CHASE
A-311
FIRE CAULK
14.8 A-503
SIM
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
16.316.6
2" RIGID INSULATION
8" CMU BACKUP
3 5/8" METAL STUD
FRAMING
5/8" GYPSUM WALL
BOARD
THERMAL INSULATION
DAMPPROOFING
NEW CONCRETE
DECK
STAIR
EXIT
CORRIDOR
2C
CEILING AS SCHEDULED
EXISTING CRAWL SPACE
RETAINING WALL TO
REMAIN
EXISTING CAMPUS-WIDE JUNCTION
BOX TO REMAIN. DO NOT MOVE, OR
DAMAGE. PROTECT THROUGHOUT
ALL CONSTRUCTION PHASES.
NEW CONCRETE SLAB
EXISTING CONCRETE SLAB
ON GRADE
A-312
_____2
A-313
CRAWL
SPACE
NEW CONCRETE SLAB.
BACKFILL AND POUR
AGAINST NEW CMU WALL.
A-503
CEILING EXPANSION JOINT,
SEE DETAIL 4/A-504
EXPANSION JOINT COVER
PLATE, SEE DETAIL 7/A-504
STEEL ANGLE, SEE STRUCTURAL
INFILL CONCRETE TO ALIGN
WITH EDGE OF METAL PANEL
AND ADJACENT SLAB
ASPHALT TOPPING PATCH,
SEE A-402
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:3
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-314
WALL SECTIONS
36 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
WALL SECTION AT MENTAL HEALTH SUITE ADDITION
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH STAIR EXIT ENCLOSURE EXIT DISCHARGE
SECOND FLOOR
12' - 8 1/4"
GROUND FLOOR
-13' - 10 1/2"
CORRIDOR
C-106
CORRIDOR
EXISTING CONCRETE
STRUCTURE TO REMAIN
EXISTING CONCRETE
STRUCTURE TO REMAIN
BRICK VENEER TO BE
DEMOLISHED FROM
BOTTOM OF EXISTING
WINDOWS TO 8 COURSES
BELOW FIRST FLOOR
DEMO BLOCK WALL,
WINDOW, SILL AND
RADIATOR
EXTERIOR
DEMOLISH EXIST. WINDOW
AND FRAME.
EXISTING RADIATOR AND
SILL TO REMAIN.
EXISTING CEILING - REMOVE
APPROX 2' AWAY FROM EXISTING
WINDOWS TO ALLOW FOR
DEMOLITION. SALVAGE AND RE-
INSTALL TIGHT TO NEW PARTITION.
SAWCUT AND
DEMOLISH EXISTING
CONCRETE RETAINING
WALL T -6" BELOW
FINISH FIRST FLOOR
EXISTING DRAIN TO REMAIN
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
GROUND FLOOR
-13' - 10 1/2"
A-301
A-301
14.6
CORRIDOR
C-106
EXISTING RETAINING WALL
TO REMAIN 10" BELOW FIRST
FLOOR ELEVATION
4" COMPACTED
AGGREGATE FILL
PERIMETER RIGID
INSULATION
VAPOR RETARDER
CONCRETE SLAB, SEE
STRUCTURAL DWGS
CONCRETE SLAB ON
METAL DECK, SEE
STRUCTURAL DWGS
2" EXPANSION JOINT COVER
PLATE, SEE DETAIL 7/A-504
NEW ALUMINUM
FLASHING AND
TERMINATION BAR
SEALANT
EXISTING BRICK
VENEER TO REMAIN
EXISTING WINDOW,
SILL, AND RADIATOR
TO REMAIN
EXISTING CONCRETE
STRUCTURE TO REMAIN
METAL ROOF DECK AND
STEEL FRAMING TO BE
FIREPROOFED WITH
SPRAY-ON INSULATION
NEW STEEL BEAM AND KICKER,
SEE STRUCTURAL DWGS CMU BLOCK INFILL
5/8" GWB ON 3 5/8"
METAL STUD
FRAMING, ALIGN AND
FINISH TO MATCH
EXISTING WALL
THERMAL INSULATION
LIQUID APPLIED
AIR/WATER BARRIER
ALL EXISTING DRAINS IN
LIGHTWELL TO REMAIN
AIR CAVITY
EXISTING LIGHTWELL AT
GROUND FLOOR TO REMAIN
INSTALL SALVAGED
ACT GRID AND TILE
EXISTING RADIATOR
TO REMAIN.
2"
2"
CEILING EXPANSION JOINT,
SEE DETAIL 4/A504
FULLY ADHERED
REINFORCED 60 MIL
TPO MEMBRANE OVER
MECH ATTACHED R-33
POLYISO INSULATION.
1/2" BIT. JOINT
2"
NEW STEEL LINTEL TO
SUPPORT EXIST BRICK
TO REMAIN. SEE STRUCT
DWGS
ALIGN
METAL DECK AND
STEEL FRAMING W/
SPRAY-ON
FIREPROOFING
GRIND, LEVEL, AND
PREPARE FLOOR TO
RECEIVE NEW FINISHES
ALONG EXTERIOR WALL
DEMOLITION
A-503
SIM
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
GROUND FLOOR
-13' - 10 1/2"
VV.1
BRICK VENEER
2" AIR GAP
RIGID INSULATION
8" CMU BACKUP,
SEE STRUCTURAL
DRAWINGS FOR
REINFORCING
3 5/8" METAL STUD FRAMING
5/8" GYPSUM WALL BOARD
CEILING AS SCHEDULED
THERMAL INSULATION
CAVITY DRAINAGE MESH,
32"H
SS FLASHING WITH DRIP
EDGE IN BED OF SEALANT
TERMINATION BAR
WEEPS 24" OC MAX
SELF-ADHERED
FLASHING
DAMPPROOFING
ALUMINUM COPING
PREFORMED CANT
2-PLY APPLIED SBS
MEMBRANE ON 5/8"
GYPSUM COVER
BOARD OVER R-33
POLI-ISO INSULATION
ROOFING MEMBRANE
3/4" FIRE RETARDANT
TREATED PLYWOOD
2X PT FIRE RESISITANT
WOOD BLOCKING
ANCHOR BOLTS @
4'-0" OC
1 1/2" METAL DECK, OVER
SLOPED ON STRUCTURAL
STEEL FRAMING WITH
SPRAY ON FIRE
PROOFING, SEE
STRUCTURAL DWGS
LIQUID APPLIED
VAPOR BARRIER
BRICK TIES @ 24" OC
SCREW
STEEL ANGLE
FIRE CAULK
TO MASONRY WALL
14'-8 1/4"
3 5/8" METAL STUD FRAMING
5/8" GYPSUM WALL BOARD
THERMAL INSULATION
NEW 12" X 36" CONCRETE
FOOTING FLUSH WITH
ADJACENT SLAB
RUN NEW DRAIN LINE
PRIOR TO POURING NEW
FOOTING
(3) #5'S
1'-6 1/2"
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:3
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-315
WALL SECTIONS
37 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
DEMO WALL SECTION THROUGH BASEMENT LIGHTWELL
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH BASEMENT LIGHTWELL
Scale: 3/4" = 1'-0"
WALL SECTION AT MENTAL HEALTH ADDITION LIGHTWELL
V.9
BRICK VENEER
2" AIR CAVITY
3" RIGID INSULATION
8" CMU BACKUP
3 5/8" METAL STUD
FRAMING
5/8" GYPSUM WALL
BOARD
CEILING AS SCHEDULED
3 1/2" THERMAL INSUL
LIQUID APPLIED
WATERPROOFING
MEMBRANE
PREFORMED CANT
ROOFING MEMBRANE
3/4" FIRE RETARDANT TREATED
PLYWOOD
ANCHOR BOLTS @ 4'-0" OC
METAL ROOF DECK ON
SLOPED STRUCTURAL
STEEL FRAMING, W/ SPRAY
ON FIRE PROOFING
BRICK TIES @ 16" OC
STEEL LINTEL, PAINT ALL
EXPOSED SURFACES
SEE STRUCTURAL DWGS
SELF-ADHERED
FLASHING W/ END DAMS
WEEP CELLS @ 24" OC
BOND BEAM LINTEL, SEE
STRUCTURAL DWGS
BACKER ROD & SEALANT
CONTINUOUS ON 3 SIDES
OF OPENING
ALUMINUM COPING
2X PT FIRE RESISTANT
WOOD BLOCKING
SCREW
STEEL ANGLE BOLTED
TO BOND BEAM
CONT SEALANT AROUND THRU
WALL PENETRATIONS TYP.
BRICK BEYOND
TYP BOND BEAM
SEE STRUCTURAL
2-PLY APPLIED SBS
MEMBRANE ON 5/8" GYPSUM
COVER BOARD OVER R-33
POLY-ISO INSULATION
TO MASONRY WALL
14'-8 1/4"
STAINLESS STEEL FLASHING
W/ 1/2" DRIP EDGE
TERMINATION BAR AND
CUT MEMBRANE SEALANT
NEW SIDEWALK, SLOPE
AWAY FROM BLDG
1" SLAB EDGE INSULATION
CENTER INDOORWAY
FILL VOID W/ MINERAL WOOL
INSULATION
5/8" GWB OVER PT
BLOCKING
GWB CORNER BEAD
CAVITY MORTAR MESH
32" HIGH, TYPICAL
DOOR THRESHOLD
BASIS OF DESIGN:
PEMKO 278_FG SERIES
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
V.9
BRICK VENEER
2" AIR GAP
RIGID INSULATION
8" CMU BACKUP
3 5/8" METAL STUD FRAMING
5/8" GYPSUM WALL BOARD
CEILING AS SCHEDULED
THERMAL INSULATION
CAVITY DRAINAGE MESH,
32"H
SS FLASHING WITH
DRIP EDGE IN BED
OF SEALANT
TERMINATION BAR
WEEPS 24" OC MAX
SELF-ADHERED
FLASHING
LIQUID APPLIED
WATERPROOFING
MEMBRANE
ALUMINUM COPING
PREFORMED CANT
2-PLY APPLIED SBS
MEMBRANE ON 5/8"
GYPSUM COVER
BOARD OVER R-33
POLY-ISO INSULATION
ROOFING MEMBRANE
3/4" FIRE RETARDANT
TREATED PLYWOOD
2X PT FIRE RESISITANT
WOOD BLOCKING
ANCHOR BOLTS @ 4'-0" OC
METAL ROOF DECK ON
STRUCTURAL STEEL FRAMING,
SEE STRUCTURAL DWGS
LIQUID APPLIED
VAPOR BARRIER
BRICK TIES @ 24" OC
SCREW
STEEL ANGLE
CAULK AROUND THRU
WALL PENETRATIONS TYP.
TO MASONRY WALL
14'-8 1/4"
GRADE TO SLOPE
AWAY FROM
BUILDING
SLAB ON GRADE, SEE
STRUCTURAL
CONCRETE GRADE BEAM,
SEE STRUCTURAL
1'-10 1/2"
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
16.6
2-PLY APPLIED SBS
MEMBRANE ON 5/8" GYPSUM
COVER BOARD OVER R-33
POLY-ISO INSULATION
PREFORMED CANT
3/4" FIRE TREATED PLYWOOD
METAL COPING TO EXTEND
OVER EXISTING RETAINING
WALL, FASTEN CLEAT TO
ADDITION SIDE ONLY FOR
MOVEMENT. BASIS OF DESIGN:
PERMA-TITE EXPANSION JOINT
FT/PT BLOCKING
THERMAL BATT INSULATION
CEILING AS SCHEDULED
5/8" GYPSUM WALL BOARD
3 5/8" METAL STUD FRAMING
TO EXTEND TO UNDERSIDE OF
SLOPING STEEL FRAMING
ABOVE
2" RIGID INSULATION CLOSED
CELL XPS
REINFORCED CMU BLOCK
WALL, SEE STRUCTURAL
EXISTING STONE VENEER
RETAINING WALL TO REMAIN
EXISTING ASPHALT DRIVE
TO REMAIN
NEW 8'-0" HIGH CHAIN LINK
SECURITY FENCE, 9" FROM FACE
OF EXISTING RETAINING WALL AND
TO EXTEND 12'-0" PAST MENTAL
HEALTH ADDITION EAST WALL
PATCH ASPHALT TIGHT
AROUND VERTICAL POST
SET VERTICAL POSTS IN
HOLES, FILL WITH
CONCRETE
8" DIAMETER
AUGER DRILLED
HOLE 3'-0" MIN DEEP
PT WOOD BLOCKING SECURE
TO CONCRETE WITH BOD HILTI
1/2" X 4" CONCRETE SCREWS,
OR EQUAL. STAGGER, 36" O.C
MIN
9 1/2"
90MIN METAL ROOF DECK ON 2HR
STEEL FRAMING. FIREPROOF AS
REQUIRED WITH SPRAY-ON INSULATION
WATER PROOF MEMBRANE
VIF
VARIES
GROUT FLUME, SLOPED
EASTWARD AT 2%
TURN DOWN SLAB, SEE
STRUCTURAL DRAWINGS
HEIGHT OF EXISTING 4"
GROUTED CMU VARIES AT
EXISTING STAIR
PERIMETER INSULATION
CLOSED CELL XPS, TYPICAL
LIQUID APPLIED CONTINUOUS
VAPOR RETARDER, TYPICAL
CONTINUOUS WATER PROOF
MEMBRANE
FIRST FLOOR
0"
14.8
EXISTING CONCRETE
LIGHTWELL RETAINING
WALL TO REMAIN
BRICK VENEER
THRU-WALL SS FLASHING
WITH DRIP EDGE ABOVE
RETAINING WALL
4X8X16 FULLY GROUTED
CMU
CONCRETE GRADE BEAM,
SEE STRUCTURAL
VAPOR BARRIER
2" PERIMETER INSULATION
COMPACTED GRAVEL,
SEE STRUCTURAL
CONCRETE SLAB ON
GRADE, SEE STRUCTURAL
NEW FIELD BRICK, BEYOND
WEEPS 24" OC MAX
9 1/2" 1'-4"
2'-2"
FIRST FLOOR
0"
SECOND FLOOR
12' - 8 1/4"
EXISTING STONE CAP
TO BE REMOVED. SEE PLAN
FOR EXTENTS
REMOVE ASPHALT AS
REQUIRED TO
ACCOMMODATE CHAIN
LINK POST INSTALLATION
PATCH ASPHALT TIGHT
AROUND VERTICAL POST
SET VERTICAL POSTS
IN HOLES, FILL WITH
CONCRETE
8" DIAMETER
AUGER DRILLED
HOLE 3'-0" MIN DEEP
STONE VENEER TO REMAIN
NEW T.O. STONE RETAINING
WALL
14' - 8 1/4"
DEMOLISH/SAWCUT PORTION
OF EXISTING STONE RETAINING
WALL - EXTENTS VARIES
16" GROUTED CMU TO REMAIN
STONE VENEER TO REMAIN
4" GROUTED BLOCK
TO REMAIN
CONCRETE RETAINING WALL
FOOTING TO REMAIN
DEMOLISH CONCRETE
STAIRS AND LANDING
DEMOLISH STAIR
STONE VENEER
DEMOLISH STAIR 12"
GROUTED CMU
HANDRAIL TO BE DEMOLISHED
DEMOLISH GUARDRAIL
WITH HANDRAIL
DEMOLISH PERFORATED
PIPE
REMOVE INFILL
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:4
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-316
WALL SECTIONS
38 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
WALL SECTION AT MENTAL HEALTH ADDITION EXIT
Scale: 3/4" = 1'-0"
WALL SECTION AT MENTAL HEALTH ADDITION
Scale: 3/4" = 1'-0"
WALL SECTION THROUGH STONE RETAINING WALL, TYPICAL
Scale: 3/4" = 1'-0"
WALL SECTION BASE AT LIGHTWELL RETAINING WALL
Scale: 3/4" = 1'-0"
DEMO WALL SECTION THROUGH STONE RETAINING WALL
THIRD FLOOR
24' - 0 3/4"
EXISTING EXTERIOR WALL TO
REMAIN
POLYISO RIGID INSULATION,
MIN R-33
METAL ROOF DECK ON
STRUCTURAL STEEL FRAMING,
SEE STRUCTURAL DWGS.
SPRAY ON FIRE INSULATION SEE
G-003
CEILING AS SCHEDULED
2 PLY SBS ROOFING
2" EXPANSION JOINT
FIRE TREATED AND PRESSURE
TREATED BLOCKING
EXISTING EXTERIOR
FLOOR, STEEL, DECK, AND
CONCRETE TO REMAIN
BATT INSULATION
5/8" GYPSUM BOARD
5/8" FIBER CEMENT BOARD
211A
ROOF SLOPE BEYOND
A-317
SCHEDULED FLOORING
NEW PT FT 3/4"
PLYWOOD, SCREW TO
EXISTING CONCRETE. 12"
O.C. BOTH WAYS
1'-6"
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
EXISTING EXTERIOR WALL
STRUCTURE TO REMAIN
CEILING AS SCHEDULED
EXISTING EXTERIOR FLOOR
STRUCTURE TO REMAIN
THERMAL BATT INSULATION
PROVIDE FLASHING TO
PREVENT WIND DRIVEN
RAIN FROM PENETRATING
THE BASE OF THE WALL.
PREFABRICATED
INSULATED METAL PANEL
SYSTEM. BASIS OF
DESIGN: CENTRIA,
FORMAWALL SERIES, 2"
THICK, TYPICAL
2"
5/8" GYPSUM WALL BOARD
COLUMN BEYOND
EXPANSION JOINT COVER
PLATE, SEE DETAIL 7/A-504
SECOND FLOOR
12' - 8 1/4"
THIRD FLOOR
24' - 0 3/4"
DEMOLISH CEILING
DEMOLISH CHASE
BEYOND
DEMOLISH WINDOWS
DEMOLISH WALL
ASSEMBLY UNDER
WINDOWS
THIRD FLOOR
24' - 0 3/4"
2 PLY SBS ROOF SYSTEM
ON 5/8" GYPSUM COVER
BOARD OVER R-33 POLY-
ISO INSUL
CUT EDGE SEALANT PER
MANUF STANDARD DTLS
ROOFING MEMBRANE FLSHG
EXTEND OVER TOP OF EXP.
JOINT FLANGES AND 6" MIN
OVER MAIN ROOF MEMBRANE
FULLY ADHERED ROOFING
MEMBRANE, OVER TOP OF
MECH FASTENED FT/PT 3/4"
PLYWOOD. EXTEND UNDER
EJ COVER ASSEMBLY AND
TERMINATION BAR
SAWCUT CONTINUOUS REGLET
IN EXISTING MORTAR JOINT,
ALIGN W/ NEW REGLET @
BRICK VENEER WALL BEYOND
2" BELLOWS EXPANSION
JOINT COVER, OVER TOP OF
TAPERED FT PT BLOCKING
CONT TERMINATION BAR.
SECURE W/ SS FASTENERS
@ 8" OC, TYPICAL
SS REGLET FLASHING W/
REMOVABLE COUNTER
FLASHING
STEEL BEAM
SPRAY FIRE
PROOFING
CONT MTL
DECKING SPRAY
FIRE PROOFING
6"
SAWCUT CONTINUOUS
REGLET IN EXISTING BRICK
VENEER WALL BEYOND
CONTINUOUS TERMINATION
BAR. SECURE TO WALL W/ SS
FASTENERS @ 8" OC, TYP.
CONTINUOUS AIR/WATER
RESISTIVE BARRIER
5/8" CEMENT BOARD
ROOFING MEMBRANE
FLSHG EXTEND LOOSELY
ACROSS EJ. FILL JOINT
CAVITY W/ THERMAL INSUL
SLOPED ROOF BEYOND
CONT FT/PT WOOD BLOCKING
THIRD FLOOR
24' - 0 3/4"
B.3
OPAQUE FILM OVER
EXISTING WINDOWS
2 PLY SBS ON 5/8" GYPSUM
COVER BOARD OVER R-33
POLYISO INSULATION
REMOVE METAL PANELS/LOUVERS
TO ALLOW ROOFING INSTALLATION
TO 8" ABOVE NEW ROOF, INSTALL
TERMINATION BAR AND METAL
FLASHING
FT/PT WOOD BLOCKING
SPRAY-ON FIREPROOF
INSULATION
SEE STRUCTURAL
DRAWINGS
AHU
ENCLOSURE
C2-211A
SECOND FLOOR
12' - 8 1/4"
REMOVE EXISTING COPING
REMOVE EXISTING ROOFING
MEMBRANE, PLYWOOD, AND
FURRING HAT CHANNELS, TYP.
REMOVE EXISTING BALLAST,
ROOFING MEMBRANE AND
ROOFING INSULATION DOWN
TO EXIST CONCRETE DECK
E X
IS
T
IN
G
V
IF
SECOND FLOOR
12' - 8 1/4"
A.2
2 1/2x4x5/16 STEEL ANGLE
ALIGN W/ TOP OF EXISTING
2 1/2 METAL STUDS
EXISTING 4" DEEP, GIRT
SUPPORT FRAMING SYSTEM
@ 36" O.C.
EXISTING INSULATED
PANEL TO REMAIN
PROTECT AS REQ'D
NEW INSULATED METAL
PANEL SYSTEM TO MATCH
EXISTING, INCLUDING MANUF,
COLOR, FINISH AND JOINT
SYSTEM. BASIS OF DESIGN
CENTRIA FORMAWALL
5/8" GWB
6" CFMF STUDS
6" BATT INSULATION
6" CFMF STUD RUNNER
5/8" FIBERGLASS FACED
SHEATHING
1/2" SEALANT
2 1/2" AND 4" THERMAL
INSULATION TO FILL CAVITY
EXISTING BRK MTL TRIM
TO REMAIN
NEW VAPOR RETARDER,
EXTEND AND WEEP OUT AT
INTERSECTION W/ EXIST
METAL PANEL
3/4" MIN CEMENTITOUS TOPPING
OVER EXIST CONC ROOF DECK.
FLOOR THICKNESS TO BE 5 1/4" MIN
4 1/2" THICK EXIST CONCRETE
THICKNESS TO BE INCREASED
TO 5 1/4" MIN TO ACHIEVE A 2HR
RATING PER UL D916
EXISTING FIRESTOPPING
INSUL TO BE UPGRADED
TO 2HR RATING AS REQ'D
EXISTING 4 1/2" CONCRETE
ROOF DECK TO REMAIN W/
EXIST 1HR UL RATING PER
UL D916
CEMENTITOUS TOPPING TO
LEVEL FLOOR
Engineers Architects
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/2
/2
:4
:4
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-317
WALL SECTIONS AND SECTION
DETAILS - AHU ENCLOSURE
39 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
WVS
Scale: 3/4" = 1'-0"
WALL SECTION AT AHUE DOOR ACCESS
Scale: 3/4" = 1'-0"
WALL SECTION AT AHUE WALL RETURN
Scale: 3/4" = 1'-0"
DEMO WALL SECTION THRU STORAGE WINDOWS
Scale: 1 1/2" = 1'-0"
ROOF DETAIL - EXPANSION JOINT AT AHUE
Scale: 1 1/2" = 1'-0"
ROOF CONNECTION DETAIL AT AHU ENCLOSURE
Scale: 1 1/2" = 1'-0"
DEMO WALL SECTION DETAIL ROOF PARAPET AT AHU
ENCLOSURE
Scale: 1 1/2" = 1'-0"
SECTION DETAIL AT AHU ENCLOSURE EXISTING PARAPET
CR
O
BED
STORAGE
C1-23
POLICE
STORAGE
C1-24
MECHANICAL
COURTYARD
C1-115
15.1
O
14.6
O
TR
C1-100A
MECHANICAL
COURTYARD
C1-115
7 7
8 8
9 9
Maa3
Ma3
A
O
TR
C1-100A
MECHANICAL
COURTYARD
C1-115
REMOVE AND INFILL EXISTING
WINDOW
DEMOLISH CEILING FAN
DEMOLISH CEILING SYSTEM
CONTRACTOR TO REMOVE
AND STORE ALL EXISTING
EQUIPMENT PRIOR TO
CONSTRUCTION
D E
M O
W A
L L S
T O
E X
T E
N T
S S
H O
W N
O N
P L A
N
CURVED HEADER TO REMAIN
Engineers Architects
# KEY NOTES:
# KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE/SMOKE BARRIER
2 HR - FIRE BARRIER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road, Suite 120 Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
S S S S
S S
S S
SMOKE RESISTIVE HAZARDOUS AREA
1 HR - FIRE BARRIER
2 HR - FIRE/SMOKE BARRIER
/2
/2
:4
:5
P
M C
U s e rs
\c k u rk u l\ D o c u m e n ts
\A
-0
-W ilk e s B a rr e M e n ta l H e a lt h c k u rk u lG
V Y
H
.r v t
A-401
ENLARGED TELECOM ROOM C1-100A
PLANS
40 49GTS
EXPAND MENTAL HEALTH
CLINIC
WILKES-BARRE VA MEDICAL CENTER
1111 EAST END BLVD
WILKES-BARRE, PA 18711 FEBRUARY 21, 2024
100% CONSTRUCTION DOCUMENTS
693-35220-083
GTS
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
A
B
A
B
Scale: 1/4" = 1'-0"
BED STORAGE C1-23 DEMO PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM C1-100A FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM C1-100A REFLECTED CEILING PLAN
A. ALL EXISTING CONDITIONS ARE BASED ON THE
BEST AVAILABLE INFORMATION AT THE TIME OF
THE SURVEY AND VISUAL INSPECTION.
CONTRACTOR SHALL FIELD VERIFY EXISTING
CONDITIONS.
B. ELEMENTS SHOWN WITH LIGHT, GRAY LINES ARE
EXISTING TO REMAIN. ELEMENTS SHOWN WITH
DARK, DASHED LINES ARE EXISTING TO BE
DEMOLISHED. DEMOLITION SHALL INCLUDE, BUT
NOT LIMITED TO, THOSE ELEMENTS SHOWN.
C. ALL WORK SHALL BE COORDINATED BETWEEN
TRADES.
D. ALL WORK SHALL BE COORDINATED WITH THE
COR TO MINIMIZE DISRUPTION OF AREAS
OUTSIDE OF THE PROJECT LIMITS OF WORK.
E. SEE A-111 FOR REFLECTED CEILING PLAN NOTES
AND LEGENDS.
F. SEE SHEET I-001 FOR FINISHES AND SIGNAGE
GENERAL NOTES.
G. TELECOM ROOM TO HAVE CARBON DIOXIDE
EXTINGUISHER WITHIN 75' OF ROOM.
NORTH
0 2 4 8
NORTH
0 2 4 8
NORTH
0 2 4 8
1 EXISTING FURRING TO REMAIN.
2 REMOVE ALL EXISTING WALL SUBSTRATES,
FINISHES AND WALL PROTECTION. EXISTING STUD
OR BLOCK TO REMAIN.
3 DEMOLISH EXISTING ACT CEILING SYSTEM,
INCLUDING ELECTRICAL AND MECHANICAL
FIXTURES.
4 EXISTING MAIN DUCT ABOVE CEILING TO REMAIN.
5 DEMOLISH COMPLETE WINDOW SYSTEM.
6 REMOVE EXISTING FLOOR FINISH AND BASE.
PREPARE TO RECEIVE NEW FLOORING AND
FINISHES AS INDICATED.
1 PROVIDE NEW METAL STUD/FURRING AS
REQUIRED TO THAT ADJOINING GYPSUM WALL
BOARD SURFACES ARE FLUSH.
2 NEW EXTERIOR WINDOW AND FURRING
REQUIRED. SEE SHEET A-602 FOR NEW WINDOW
SCHEDULE AND DETAILS.
3 NEW FLOORING, SEE SCHEDULE ON I-001.
4 EXTEND STATIC DISSAPATIVE TILE UNDER DOOR
TO ADJACENT FLOORING.
5 3/4" FIRE RETARDANT PLYWOOD APPLIED OVER
GYPSUM BOARD FOR MOUNTING OF
TELECOMMUNICATIONS EQUIPMENT. 8" AFF TO
8'-8" AFF, PAINT WITH (3) COATS OF FIRE
RETARDANT PAINT.
6 NEW CORNER GUARD
7 TELECOMMUNICATIONS CHANNEL RACK, REFER
TO TECHNOLOGY DRAWINGS.
8 ELECTRICAL PANEL, SEE ELECTRICAL DRAWINGS.
9 PAC EQUIPMENT, SEE ELECTRICAL DRAWINGS.
10 NEW AHU, SEE MECHANICAL DWGS.
11 EXPOSED TO STRUCTURE
12 INDOOR MINISPLIT SYSTEM, SEE MECHANICAL
DRAWINGS.
13 NEW FACE BRICK TO MATCH EXISTING. MATCH
BRICK COLOR, BOND, MORTAR COLOR. OPENING
4'-4" X 5'-4" - VIF.
14 CMU BACKUP MASONRY WITH CONT. 2"
INSULATION TO EXTERIOR. CAVITY WALL
CONSTRUCTION.
15 3 5/8" METAL STUDS WITH 3 1/2" BATT INSULATION
AND 5/8" GWB TO INTERIOR.
Scale: No Scale
PHOTO REFERENCE - BED STORAGE C1-23 WINDOW
S.6
16.6
C2
2 HR FIRE RATED EXPANSION
JOINT AND JOINT COVER
BELOW, SEE DETAIL 7/A-504
ROOF
BELOW
HSS 6x6 STEEL TUBE COLUMNS
SEE STRUCTURAL DRAWINGS
INTUMESCENT PAINT TO ACHIEVE
A 2 HR FIRE RESISTANCE RATING,
TYPICAL
EXTEND UNCUT END OF 1" GWB
LINER PANEL, FLUSH TO FIRE
TREATED TUBE AND FIRE CAULK
CONT. BOTH SIDES OF COLUMN
A-313
MAX
4"
WINDOW FILM ON INTERIOR
FACE OF WINDOW, SEE
INTERIOR FINISHES
VERTICAL EXPANSION JOINT
COVER BASIS OF DESIGN INPRO
104 SERIES SURFACE MOUNT A01
WALL TO WALL - 104-A07-050.
A-503
METAL COPING OVER
BUILT UP CURB TO
MATCH ADJACENT, SEE
DETAILS 5&6/A-402
2 HR RATED VERTICAL EXP JOINT,
BASIS OF DESIGN INPRO FIRELINE
F140 BLANKET W/ SPRINGS
SAWCUT END OF EXIST STONE WALL
ABOVE SIDEWALK AND DEMOLISH
WALL TOWARDS EXISTING BUILDING.
EXPOSED END TO BE WRAPPED IN
SBS ROOFING MEMBRANE.
LOCATION OF FIRST
FENCE POST.
INSULATED METAL PANEL,
COLOR TO MATCH
EXISTING. BASIS OF
DESIGN: CENTRIA
FORMAWALL DIMENSION
SERIES. FASTEN TO STUDS
@16" O.C. OVER 1/4"
SPACERS
/2
11 1/2"
A-503
ALIGN SLAB W/ SECOND FLOOR ELEV. AT DOOR C2
5'-0"
SLOPE
METAL COPING BETWEEN NEW
CMU PARAPET AND EXISTING
STONE VENEER ON CMU
RETAINING WALL
/2
ASPHALT PATCH TO EXTEND 12" SOUTH OF METAL PANEL WALL AND NEW SLAB
12"X24"X6"H PRECAST
CONCRETE SPLASH BLOCK
VIF
12'-7"
A-402
2 HR RATED HORZ EXP JOINT,
BASIS OF DESIGN INPRO FIRELINE
F140 BLANKET W/ SPRINGS
VERTICAL EXPANSION JOINT
COVER BASIS OF DESIGN INPRO
615 SERIES FLUSH MOUNT, WALL
TO WALL - 615-A07-050. PROVIDE
FACTORY TRANSITIONS AT EJ
INTERSECTION, TYPICAL
A-402
EXISTING ASPHALT DRIVE AISLE
S
S.1 S.4
14.6
A-311
INSULATED METAL PANEL
BASIS OF DESIGN: CENTRIA
FORMAWALL
2 HR RATED HORZ
EXP JOINT, BASIS
OF DESIGN INPRO
FIRELINE F140
BLANKET W/
SPRINGS
2 HR FIRE RATED EXPANSION
JOINT AND JOINT COVER
BELOW, SEE DETAIL 7/A-504
HSS 6x6 STEEL TUBE COLS
SEE STRUCT DWGS
INTUMESCENT PAINT TO
ACHIEVE A 2 HR FIRE RESIST
RATING, TYPICAL.
2 HR RATED VERTICAL EXP JOINT,
BASIS OF DESIGN INPRO FIRELINE
F140 BLANKET W/ SPRINGS
MECH CHASE
14.8
MECH DUCTS W/ FIRE
DAMPERS AT FLOOR
2 HR RATED VERT EXP
JOINT, BASIS OF DESIGN
INPRO FIRELINE F140
BLANKET W/ SPRINGS
VERTICAL EXP JOINT COVER
BASIS OF DESIGN INPRO 104
SERIES SURFACE MOUNT A01
WALL TO WALL - 104-A07-050.
GLAZED CMU TO
REMAIN, PROTECT
AS REQUIRED
ALUM EXTRUSION TO MATCH
EXISTING WINDOW FRAME
3/4" PT/FR PLYWOOD OVER
6" STUDS
VERTICAL EXP JOINT COVER BASIS
OF DESIGN INPRO 615 SERIES
FLUSH MOUNT, WALL TO WALL -
615-A07-050. PROVIDE FACTORY
TRANSITIONS AT EJ INTERSECTION,
TYPICAL
(2) LAYERS 5/8" GWB
OVER 7/8" HAT CHANNEL,
HORIZONTALLY @ 16" OC
90 MIN FIRE RATED EXP JT
ALONG PERIMETER OF ROOF
BELOW, SEE DETAIL 1/A-503
FRAME TIGHT
AGAINST EXISTING
UTILITY LINES, VIF
4'-0"
5/8" GWB ON METAL STUD TO
ALIGN W/ ADJACENT WALL. MATCH
FINISHES AND WALL BASE
Ssb4
Ssb4
Ma3 Ma3
ALIGN
(2) LAYERS 5/8" GWB TO
WRAP COLUMN CORNER
INTUMESCENT PAINT TO
ACHIEVE A 2 HR FIRE
RESISTANCE RATING, TYP
2 HR RATED HORZ EXP JOINT, BASIS
OF DESIGN INPRO FIRELINE F140
BLANKET W/ SPRINGS
A-402
S S.1
2 HR FIRE RATED EXP
JOINT AND JOINT COVER
BELOW, SEE DETAIL 7/A-504
HSS 6x6 STEEL TUBE COLS
SEE STRUCT DWGS
INTUMESCENT PAINT TO
ACHIEVE A 2 HR FIRE
RESISTANCE RATING, TYP
EXTEND UNCUT END OF 1"
GWB LINER PANEL, FLUSH TO
FIRE TREATED TUBE & FIRE
CAULK CONTINUOUS BOTH
SIDES OF COLUMN
VERTICAL EXP JOINT
COVER, BASIS OF DESIGN
INPRO 101 SERIES RECESS
MOUNT A07 WALL TO WALL
101-A07-050.
2 HR RATED VERTICAL EXP
JOINT, BASIS OF DESIGN
INPRO FIRELINE F140
BLANKET W/ SPRINGS
2 HR RATED HORZ EXP JOINT,
BASIS OF DESIGN INPRO
FIRELINE F140 BLANKET W/
SPRINGS
/4
/4
STEEL J-TRACK, SHAFTWALL
DEEP LEG, BASIS OF DESIGN
CLARK DIETRICH
BLAZEFRAME JR 1
" 3
2 HOUR SHAFT WALL END
WALL DETAIL, SIMILAR TO
CORNER DETAIL SW-621 BY
NATIONAL GYPSUM CO
ALIGN WALL & FLOOR
EXPANSION JOINTS AS
SHOWN, TYPICAL
LINE OF EXISTING EXTERIOR
WALL TO REMAIN
S S.1
FILL…