ATTACHMENT 5B - Asbestos Survey (Bldg 121).pdf

PDF 725 KB Posted

Attached to
Demo Old Combat Comm Sq Bldgs 109 & 121
Solicitation number
W50S8Q-20-B-0007
Issued by

About this file

This document includes an asbestos survey report and related federal contract opportunity notice. The asbestos survey report details sampling conducted at Building 121 at 1273 F Avenue in Springfield, Ohio, identifying ceiling tiles, floor tiles, mastics, and plaster in various rooms. Laboratory analysis found chrysotile asbestos in some floor tiles and mastics at levels of 3-5%.

The related federal contract opportunity is a solicitation to demolish Buildings 109 and 121 at the Springfield Air National Guard Base in Springfield, Ohio. The project includes asbestos abatement in both buildings, demolishing pavement and properly capping utilities. The construction duration is 100 calendar days with a completion date in 2020. The total contract value is between $1-5 million. The solicitation is set aside for women-owned small businesses and responses are due on September 24, 2020.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1507 Chambers Road / Columbus OH, 43212 (614) 488-1022

April 9th, 2019

To: Ohio Air National Guard

Attention: Nicholas Owens

Phone: (937) 424-6739

Email: nicholas.r.owens3.nfg@mail.mil

Re: Asbestos Survey Building 121 1273 F Avenue Springfield, OH 45502

Mr. Owens, Enclosed please find the results of our asbestos survey and bulk asbestos sampling at Building 121, 1273 F Avenue in Springfield, Ohio.

The following is a summary of the work effort, and a discussion of the results along with recommendations and proposals.

Industrial Hygiene Division Project # 040319-2

2019 1 mailto:nicholas.r.owens3.nfg@mail.mil

I. Summary:

On Wednesday, April 3rd, 2019 Lyle Environmental personnel (Tom Eggers, Asbestos Hazard Evaluation Specialist, Certification Number ES36032) conducted an asbestos survey at Building 121, 1273 F Avenue in Springfield, Ohio. Representative samples were taken inside the structure and from the exterior. Homogeneous areas were identified and samples were taken within those areas at random locations.

Sampling of Materials and 3-5-7 Rule:

According to EPA sampling guidelines, there are three main types of material: surfacing, thermal, and miscellaneous. The classification dictates the number of samples to be taken.

Surfacing material is sampled according to the 3-5-7 rule, meaning 3 samples should be taken from areas less than 1,000 square feet; 5 samples from areas of 1,000 to 5,000 square feet; and 7 samples from areas greater than 5,000 square feet. Each of these areas is considered a “homogeneous area,” meaning it was determined by the Hazard Evaluation Specialist to be the same material judging by its appearance, age, location, etc. For Thermal system materials, with some exceptions, 3 samples should be taken for each homogeneous area. For Miscellaneous materials, at least one sample should be taken from each homogeneous material.

Laboratory Analysis:

All samples were analyzed SanAir Technologies Laboratory, Inc. located at 1551 Oakbridge Dr., Suite B, Powhatan, Va 23139. SanAir Technologies Laboratory, Inc. is accredited by the National Voluntary Laboratory Accreditation Program (NVLAP LAB CODE 200870-0) and the American Industrial Hygiene Association (AIHA #162952).

The samples were analyzed for asbestos by polarized light microscopy (PLM) in accordance with the “EPA Method for the Determination of Asbestos in Bulk Building Materials” (EPA/600/R-93/116 July 1993). Analysis was performed by using bulk samples for visual observation and slide preparation(s) for microscopic examination and identification. The samples were mounted on slides and then analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite, actinolite/tremolite), and fibrous nonasbestos constituents (mineral wool, fiberglass, cellulose, etc.).

The microscopist visually estimated relative amounts of each constituent by determining the volume of each constituent in proportion to the total volume of the sample, using a stereoscope.

Samples which were visually determined to have 4% or less asbestos were quantified more

Industrial Hygiene Division Project # 040319-2

2019 2 precisely using a “Point Count” procedure. An ocular reticule (cross hair or point array) was used to visually superimpose a point or points on the microscope fieldof view. A total of 400 points superimposed on either asbestos fibers or nonasbestos matrix material must be counted over at least eight different preparations of representative subsamples. If an asbestos fiber and matrix particle overlap so that a point is superimposed on their visual intersection, a point is scored for both categories. Point counting provides a quantification of the area percent asbestos. Point counted results supersede the results of the visual estimation.

Summary of Asbestos-Containing Materials Found:

II. Sampling:

Asbestos Survey at: Building 121 1273 F Avenue

Springfield, OH 45502

(see attached map for sampling locations)

Sample

Sample Location Sample Description

Sample Appearance Result %

1 Room 105 Ceiling Tile White NAD -

2 Hallway 102 Ceiling Tile White NAD -

3 Hallway 102 Fiberglass Insulation Above Ceiling Tile

Yellow NAD -

4 Hallway 102 Tile White POSITIVE

(CHRYSOTILE)

5%

5 A Hallway 102 Mastic Black POSITIVE

(CHRYSOTILE)

3%

5 B Hallway 102 Mastic Yellow NAD -

6 Room 118 Tile White POSITIVE

(CHRYSOTILE)

5%

7 Room 118 Mastic Black POSITIVE

(CHRYSOTILE)

4%

8 Hallway 102 Wallpaper White NAD -

9 Room 108 Plaster - Base Grey NAD -

10 Room 108 Plaster - Skim Coat White NAD -

11 Room 106 Plaster - Base Grey NAD -

12 Room 106 Plaster - Skim Coat White NAD -

13 Room 106 Plaster - Base Grey NAD -

2019 3

14 Room 106 Plaster - Skim Coat White NAD -

15 A Room 109 Hard Joint Off-White NEGATIVE (as per EPA definition)

<1% Amosite

15 B Room 109 Hard Joint Off-White NEGATIVE (as per EPA definition)

<1% Amosite

15 C Room 109 Hard Joint Off-White NEGATIVE (as per EPA definition)

<1% Amosite

16 Room 105 Window Caulk Green NAD -

17 Room 105 Window Caulk Green NAD -

18 Room 102 A Exterior Caulk Off-White NAD -

19 Room 109 Window Glazing Grey NEGATIVE (as per EPA definition)

<1% Chrysotile

20 Room 113 Built Up Roofing Black NAD -

21 Room 113 Roof Sealant Black NAD -

22 Room 105 Built Up Roofing Black NAD -

23 Room 105 Roof Sealant Black NAD -

NAD = No Asbestos Detected

2019 4

III. Drawings:

Building 121

IV. Results:

Summary of Asbestos-Containing Materials Found:

1st (ground) floor: Tile: Approximately 5,000 sq. ft.

Mastic: Approximately 5,000 sq. ft.

Note: See Laboratory Results in Appendix A

2019 5

V. Discussion:

The tile and mastic samples taken from this structure (#4, #5, #6, and #7) came back positive for asbestos. This material should only be removed/disturbed by a licensed asbestos abatement contractor. However, as these are category 1 non-friable asbestos-containing materials, which are in good condition, they may remain in place during demolition, assuming the demolition activities do not render it friable, and assuming the structure will not be subjected to a controlled burn.

All other areas tested for asbestos were legally considered non-asbestos containing.

Please note that samples #15A, #15B, #15C, and #19 had less than 1% asbestos, which is not legally considered ACM (asbestos containing material), as per definition in 29 CFR 1910.10.

These materials (<1% asbestos) may remain in place during demolition.

Respectfully submitted, Thomas Eggers April 9th, 2019 Thomas L. Eggers Date Asbestos Hazard Evaluation Specialist Certification Number (ES36032)

ELECTRONICALLY CERTIFIED

2019 6

Appendix A

SanAir ID#: 19015767

Project #: 040319-1

Project Name: Ohio Air Nat. Guard 121

Report Date: 4/5/2019

Analysis Report prepared for Lyle Environmental

Dear Tom Eggers, We at SanAir would like to thank you for the work you recently submitted. The 25 sample(s) were received on Thursday, April 04, 2019 via FedEx. The final report(s) is enclosed for the following sample(s): 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15A, 15B, 15C, 16, 17, 18, 19, 20, 21, 22, 23.

These results only pertain to this job and should not be used in the interpretation of any other job. This report is only complete in its entirety. Refer to the listing below of the pages included in a complete final report.

Sincerely, Sandra Sobrino Asbestos & Materials Laboratory Manager SanAir Technologies Laboratory

Final Report Includes:

- Cover Letter

- Analysis Pages

- Disclaimers and Additional Information

Sample conditions:

- 25 samples in Good condition.

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

040319-1Project Number:

P.O. Number:

Project Name: Ohio Air Nat. Guard 121

4/3/2019Collected Date:

4/4/2019 9:35:00 AMReceived Date:

4/5/2019 5:00:34 PM

19015767 SanAir ID Number

FINAL REPORT

Lyle EnvironmentalName:

Address: 1507 Chambers Rd

Columbus, OH 43212

614-488-1022Phone:

Analyst: Fleming, Christopher

Asbestos Bulk PLM EPA 600/R-93/116 Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

1 / 19015767-001 Ceiling Tile

White Fibrous

Homogeneous

60% Cellulose 40% Other None Detected

2 / 19015767-002 Ceiling Tile

White Fibrous

Homogeneous

60% Cellulose 40% Other None Detected

3 / 19015767-003 Fiberglass Insulation Above

Yellow Fibrous

Homogeneous

95% Glass 5% Other None Detected

4 / 19015767-004 Tile

White Non-Fibrous

Homogeneous

95% Other 5% Chrysotile

5 / 19015767-005 Mastic, Mastic

Black Non-Fibrous

Homogeneous

97% Other 3% Chrysotile

5 / 19015767-005 Mastic, Mastic

Yellow Non-Fibrous

Homogeneous

100% Other None Detected

6 / 19015767-006 Tile

White Non-Fibrous

Homogeneous

95% Other 5% Chrysotile

7 / 19015767-007 Mastic

Black Non-Fibrous

Homogeneous

96% Other 4% Chrysotile

8 / 19015767-008 Wallpaper

White Fibrous

Homogeneous

70% Cellulose 30% Other None Detected

9 / 19015767-009 Plaster -Base

Grey Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/5/2019 Date: 4/5/2019

Approved Signatory:

040319-1Project Number:

P.O. Number:

Project Name: Ohio Air Nat. Guard 121

4/3/2019Collected Date:

4/4/2019 9:35:00 AMReceived Date:

4/5/2019 5:00:34 PM

19015767 SanAir ID Number

FINAL REPORT

Lyle EnvironmentalName:

Address: 1507 Chambers Rd

Columbus, OH 43212

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

10 / 19015767-010 Plaster -Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

11 / 19015767-011 Plaster -Base

Grey Non-Fibrous

Homogeneous

100% Other None Detected

12 / 19015767-012 Plaster -Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

13 / 19015767-013 Plaster -Base

Grey Non-Fibrous

Homogeneous

100% Other None Detected

14 / 19015767-014 Plaster -Skim Coat

White Non-Fibrous

Homogeneous

100% Other None Detected

15A / 19015767-015 Hard Joint

Off-White Non-Fibrous

Homogeneous

100% Other < 1% Amosite

15B / 19015767-016 Hard Joint

Off-White Non-Fibrous

Homogeneous

100% Other < 1% Amosite

15C / 19015767-017 Hard Joint

Off-White Non-Fibrous

Homogeneous

100% Other < 1% Amosite

16 / 19015767-018 Window Caulk

Green Non-Fibrous

Homogeneous

100% Other None Detected

17 / 19015767-019 Window Caulk

Green Non-Fibrous

Homogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/5/2019 Date: 4/5/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

040319-1Project Number:

P.O. Number:

Project Name: Ohio Air Nat. Guard 121

4/3/2019Collected Date:

4/4/2019 9:35:00 AMReceived Date:

4/5/2019 5:00:34 PM

19015767 SanAir ID Number

FINAL REPORT

Lyle EnvironmentalName:

Address: 1507 Chambers Rd

Columbus, OH 43212

Stereoscopic Components

SanAir ID / Description Appearance % Fibrous % Non-fibrous Asbestos Fibers

18 / 19015767-020 Exterior Caulk

Off-White Non-Fibrous

Homogeneous

100% Other None Detected

19 / 19015767-021 Window Glazing

Grey Non-Fibrous

Homogeneous

100% Other < 1% Chrysotile

20 / 19015767-022 Built-Up Roofing

Black Non-Fibrous

Heterogeneous

100% Other None Detected

21 / 19015767-023 Roof Sealant

Black Non-Fibrous

Heterogeneous

100% Other None Detected

22 / 19015767-024 Built-Up Roofing

Black Non-Fibrous

Heterogeneous

100% Other None Detected

23 / 19015767-025 Roofing Sealant

Black Non-Fibrous

Heterogeneous

100% Other None Detected

Analyst:

Analysis Date: 4/5/2019 Date: 4/5/2019

Approved Signatory:

1551 Oakbridge Dr. Suite B, Powhatan, VA 23139 | 804.897.1177 | Fax: 804.897.0070 | www.SanAir.com | IAQ@SanAir.com

040319-1Project Number:

P.O. Number:

Project Name: Ohio Air Nat. Guard 121

4/3/2019Collected Date:

4/4/2019 9:35:00 AMReceived Date:

4/5/2019 5:00:34 PM

19015767 SanAir ID Number

FINAL REPORT

Lyle EnvironmentalName:

Address: 1507 Chambers Rd

Columbus, OH 43212

Disclaimer

The final report cannot be reproduced, except in full, without written authorization from SanAir.

Fibers smaller than 5 microns cannot be seen with this method due to scope limitations. The accuracy of the results is dependent upon the client’s sampling procedure and information provided to the laboratory by the client. SanAir assumes no responsibility for the sampling procedure and will provide evaluation reports based solely on the sample and information provided by the client. This report may not be used by the client to claim product endorsement by NVLAP or any other agency of the U.S. government. Samples are held for a period of 60 days.

For NY state samples, method EPA 600/M4-82-020 is performed.

Polarized- light microscopy is not consistently reliable in detecting asbestos in floor covering and similar non-friable organically bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can be considered or treated as non-asbestos containing.

Asbestos Certifications NVLAP lab code 200870 City of Philadelphia: ALL-460 PA Department of Environmental Protection Number: 68-05397 California License Number: 2915 Colorado License Number: AL-23143 Connecticut License Number: PH-0105 Massachusetts License Number: AA000222 Maine License Number: LB-0075 New York ELAP lab ID: 11983 Rhode Island License Number: AAL-126 Texas Department of State Health Services License Number: 300440 Commonwealth of Virginia 3333000323 Washington State License Number: C989 West Virginia License Number: LT000566 Vermont License: AL166318

Revision Date: 11/30/2017