Attachment 5 - Drawings - Options 2 and 3.pdf
PDF 6 MB Posted
- Attached to
- Recirculating Aquaculture System Upgrades Federal contract opportunity
- Solicitation number
- 1232SA26Q0302
About this file
This file is a set of design and construction drawings for the Recirculating Aquaculture Upgrades project at the National Cold-Water Marine Aquaculture Center (NCWMAC) in Franklin, Maine, under USDA Agricultural Research Service contract number 12305B21D0013/12305B24F0110.
The project involves upgrading the facility's recirculating aquaculture system with three primary mechanical components: providing process water cooling and ozone injection for salmon broodstock production. The scope includes installation of three 15-20 ton air-cooled chillers (C-1, C-2, C-3) serving the Brood 3, Parr, and Smolt 2 treatment bays respectively; a 31.2 PPD ozone generator (OZ-1) with integrated 4.5-ton chiller, housed in a prefabricated fiberglass equipment building with electrical controls and safety systems; and associated piping, filtration, and distribution systems for ozone supply to existing low-head oxygenators. The electrical work requires establishing new 480V/277V three-phase power distribution through multiple panelboards (MDP-2, P-H1, P-H2) with branch circuits serving the new mechanical equipment, including a 1000 KVA transformer and automatic transfer switch for emergency backup power. Construction materials must comply with Buy American Act requirements, existing facility operations must be maintained throughout construction, and all work must meet IBC 2021 design standards with 20 PSF ground snow load and 117 MPH ultimate wind speed design criteria.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30 - Amendment 02.pdf | ||
| RFI 2 - Clarification.pdf | ||
| Site Visit Sign In Sheet - Mar 17.pdf | ||
| SF30 - Amendment 01.pdf | ||
| RFIs.pdf | ||
| Site Visit Sign In Sheet - Mar 18.pdf | ||
| Attachment 1 - Solicitation Terms and Conditions.pdf | ||
| Attachment 2 - Drawings - Base.pdf | ||
| Attachment 3 - Specifications - Base.pdf | ||
| Attachment 4 - Drawing - Option 1.pdf | ||
| Wage Determination.pdf | ||
| Attachment 6 - Specifications - Options 2 and 3.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
COVER SHEET
T-100 1 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
USDA
LOCATION MAPVICINITY MAP NO SCALE
N N
NO SCALE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER (NCWMAC)
25 SALMON FARM ROAD
FRANKLIN, ME
PROJECT
LOCATION
GENERAL PROJECT DESCRIPTION
THE PURPOSE OF THIS PROJECT IS TO PROVIDE PROCESS WATER COOLING AND OZONE INJECTION FOR SALMON BROODSTOCK
PRODUCTION.
GENERAL SITE REQUIREMENTS
A. ALL NCWMAC BIOSECURITY PROTOCOLS SHALL BE FOLLOWED AT ALL TIMES. PRIOR TO COMMENCING WORK, THE CONTRACTOR SHALL
OBTAIN THESE REQUIREMENTS IN WRITING FROM USDA.
B. UNINTERRUPTED OPERATION OF THE FACILITY IS REQUIRED. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING SAFE
UNINTERRUPTED OPERATION OF THE FACILITY THROUGHOUT THE PROGRESS OF CONSTRUCTION.
C. LAYDOWN SPACE INSIDE OF THE BUILDINGS IS NOT AVAILABLE. ALL CONSTRUCTION MATERIALS SHALL BE STORED OUTSIDE OF THE
BUILDINGS IN AN AREA IDENTIFIED BY THE GOVERNMENT.
U.S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
RECIRCULATING AQUACULTURE UPGRADES
CONTRACT NO: 12305B21D0013/12305B24F0110
NATIONAL COLD-WATER MARINE AQUACULTURE CENTER (NCWMAC)
FRANKLIN, ME
SALMON
FARM RD.
NCWMAC
PROJECT
LOCATION.
TAUTON BAYSHORES RD.TAUTON BAY
PUMPHOUSE
S. BAY RD.
CCAR MAIN BUILDING
Emilie Oakes sam ME seal
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
DRAWING INDEX
G-100 2 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
SHEET
INDEX OF DRAWINGS
DRAWING NO. TITLE
T-100 1 OF 22 COVER SHEET
G-100 2 OF 22 DRAWING INDEX
M-001 3 OF 22 GENERAL NOTES AND ABBREVIATIONS
M-101 4 OF 22 OVERALL MECHANICAL PLAN
M-102 5 OF 22 OVERALL OZONE DISTRIBUTION PLAN
M-103 6 OF 22 MECHANICAL ROOF PLAN
M-104 7 OF 22 OZONE GENERATOR BUILDING PLAN
M-401 8 OF 22 ENLARGED MECHANICAL PLAN
M-601 9 OF 22 MECHANICAL SCHEDULES
M-602 10 OF 22 MECHANICAL DETAILS
M-603 11 OF 22 MECHANICAL DETAILS
M-604 12 OF 22 MECHANICAL DETAILS
M-605 13 OF 22 MECHANICAL DETAILS
M-606 14 OF 22 OZONE GENERATOR PID
M-607 15 OF 22 OZONE GENERATOR DIAGRAMS
M-608 16 OF 22 MECHANICAL DIAGRAMS
E-001 17 OF 22 ELECTRICAL GENERAL NOTES
E-002 18 OF 22 ELECTRICAL LEGEND
E-101 19 OF 22 POWER PLAN
E-501 20 OF 22 SCHEDULES AND DETAILS
E-601 21 OF 22 POWER RISER
E-602 22 OF 22 PANEL SCHEDULES
GENERAL NOTES:
1. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS BEFORE COMMENCING WORK. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, CONDITIONS, AND EXISTING
STRUCTURES AND EQUIPMENT AT THE JOB SITE. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER OF ANY DISCREPANCIES FOUND PRIOR TO THE START OF
CONSTRUCTION.
2. THE CONTRACTOR IS REQUIRED TO TAKE PRECAUTIONARY MEASURES TO PROTECT ALL EXISTING UTILITY LINES, STRUCTURES, EQUIPMENT, ETC. IN THE AREAS OF WORK, WHETHER OR NOT SHOWN ON THESE PLANS. ALL DAMAGES CAUSED BY THE CONTRACTOR SHALL BE REPAIRED TO LIKE-NEW CONDITION AND AT THE EXPENSE OF THE CONTRACTOR. IN CASE OF EMERGENCY, IMMEDIATELY NOTIFY THE CONTRACTING OFFICER.
3. CONTRACTOR SHALL PROVIDE THEIR OWN PORTABLE SANITARY FACILITIES IN THE LOCATION APPROVED BY THE CONTRACTING OFFICER. PORTABLE SANITARY
FACILITIES SHALL BE MAINTAINED REGULARLY FOR ODOR CONTROL AND APPEARANCE.
PLUMBING ABBREVIATIONS:
' INCHES
" FEET
ABA ARCHITECTURAL BARIERS ACT
AC AIR COMPRESSOR
AD AIR DRYER
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISHED FLOOR
ARCH ARCHITECTURE, ARCHITECTURAL
AWWA AMERICAN WATER WORKS ASSOCIATION
BFP BACKFLOW PREVENTER
CA COMPRESSED AIR
CO CLEANOUT
CW COLD WATER (POTABLE / DOMESTIC)
DEG.,° DEGREES
DHWR DOMESTIC HOT WATER RETURN
DIA DIAMETER
DWG DRAWING
EDF ELECTRIC DRINKING FOUNTAIN
ET EXPANSION TANK
EWH ELECTRIC WATER HEATER
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FOG FAT OILS GREASE
GAL GALLON(S)
GCO GROUND CLEANOUT
GPF GALLONS PER FLUSH
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HR HOSE REEL
HP HORSEPOWER
HW HOT WATER (POTABLE / DOMESTIC)
HWT HOT WATER STORAGE TANK
HWCP HOT WATER CIRCULATION PUMP
IBC INTERNATIONAL BUILDING CODE
IMB ICE MAKER BOX
ID,I.D. INSIDE DIAMETER
IPC INTERNATIONAL PLUMBING CODE
KW,kW KILOWATT
LB POUNDS
LV LAVATORY
LHO LOW HEAD OXYGENATOR
MFR MANUFACTURER
MS MOP SINK
NPT NATIONAL PIPE THREAD
NTS NOT TO SCALE
02 OXYGEN
03 OZONE
P, PLBG PLUMBING
PDI PLUMBING DRAINAGE INSTITUTE
PH PHASE(S)
PSIG POUNDS PER SQUARE INCH (GAUGE)
RPZ REDUCED PRESSURE ZONE
S, SS SANITARY SEWERS,
SCFM STANDARD CUBIC FEET PER MINUTE
SH SHOWER
SK SINK
SSEW SAFETY SHOWER WITH EYE WASH
T&P TEMPERATURE AND PRESSURE RELIEF VALVE
TYP TYPICAL
U/G UNDERGROUND
UH UNIT HEATER
UR URINAL
V VENT PIPING, VOLTS
VTR VENT THROUGH ROOF
WC WATER CLOSET
WCO WALL CLEANOUT
WH WALL HYDRANT, WATER HAMMER
WHA WATER HAMMER ARRESTOR
WM WATER METER
NOTES:
1. UNDERLINED FIXTURE AND EQUIPMENT MARKS (SUCH AS WC) ARE NOT
ABBREVIATIONS. REFER TO THE PLUMBING SCHEDULE SHEETS, P601 -
P699 FOR FIXTURE AND EQUIPMENT DESCRIPTIONS. FIXTURE MARKS ARE
ALSO LISTED HERE FOR CLARITY.
2. ALL ABBREVIATIONS MAY NOT BE USED IN THIS PROJECT.
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-001
GENERAL NOTES AND ABBREVIATIONS
04/18/25
TT
JH
FJ
3 21
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OR PURCHASE OF EQUIPMENT, MATERIALS, AND ASSEMBLIES. ANY DEVIATIONS SHALL BE BROUGHT TO THE CONTRACTING OFFICER'S ATTENTION FOR RESOLUTION BEFORE PROCEEDING
WITH ANY CONSTRUCTION, FABRICATION, OR EQUIPMENT PURCHASE.
2. THESE DRAWINGS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL POSSIBLE CONDITIONS (DO NOT SCALE FOR LOCATIONS).
THE CONTRACTOR SHALL PROVIDE COMPLETE AND SYSTEM AS INDICATED WITH ALL NECESSARY EQUIPMENT, APPURTENANCES AND CONTROLS
REQUIRED.
3. THE CONTRACTOR SHALL REVIEW THE DRAWINGS OF OTHER TRADES AS PART OF THIS CONTRACT FOR ADDITIONAL WORK REQUIRED AND FOR
COORDINATION OF ALL WORK FOR OPERATIONS OF OR CONNECTIONS TO OTHER TRADES.
4. CONTRACTOR SHALL EMPLOY WORKMEN WHO ARE TRAINED AND EXPERIENCED IN NECESSARY SKILLS TO PERFORM INDICATED WORK.
5. MAKE OFFSETS AND TRANSITIONS TO COORDINATE WITH OTHER TRADES WITHOUT ANY ADDITIONAL EXPENSE TO THE OWNER.
6. CONTRACTOR SHALL PROVIDE COORDINATION/SHOP DRAWINGS OF ALL PIPING BEFORE FABIRCATION OR INSTALLATION OF PIPING.
7. CONTRACTOR SHALL FIELD VERIFY EXACT LOCATIONS AND POINTS OF CONNECTIONS TO ALL UTILITIES AND SHALL COORDINATE WITH OTHER
TRADES.
8. REFER TO SPECIFICATIONS, SHEET NOTES, DETAILS AND SCHEDULES FOR ADDITIONAL REQUIREMENTS PERTAINING TO THE WORK.
9. ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, SYSTEMS, SUPPORTS, ETC.) MUST COMPLY WITH THE REQUIREMENTS OF ALL CODES, CODE AMENDMENTS, AND ORDINANCES AS USED, ADOPTED AND/OR ENFORCED BY THE LOCAL JURISDICTION, COUNTY AND STATE IN WHICH THE PROJECT IS LOCATED. WHERE INSPECTIONS ARE REQUIRED BY C.O., WORK MUST NOT BE CONCEALED UNTIL INSPECTIONS AND
TESTS ARE COMPLETED AND ACCEPTED. REFER TO SPECIFICATIONS FOR APPLICABLE CODES.
10. SCHEDULES, NOTES OR SPECIFICATIONS MAY REFERENCE "BASIS OF DESIGN" INFORMATION REGARDING A SPECIFIC MANUFACTURER OR MODEL NUMBER. SUCH INFORMATION IS PROVIDED SO AS TO ESTABLISH A STANDARD OF PERFORMANCE, QUALITY, FEATURES AND OPTIONS (SEE SCHEDULES AND SPECIFICATIONS). THE INTENT IS NOT TO LIMIT COMPETITION. EQUIVALENT EQUIPMENT OF OTHER MANUFACTURERS SHALL BE ACCEPTABLE PROVIDED SUCH EQUIPMENT EQUALS OR EXCEEDS THE BASIS OF DESIGN EQUIPMENT IN PERFORMANCE, QUALITY, FEATURES AND
OPTIONS WHETHER SPECIFIED, SCHEDULED OR NOTED.
11. ALL EQUIPMENT FURNISHED FOR THIS PROJECT MUST COMPLY WITH THE "BUY AMERICAN ACT".
12. ALL WORK IS TO BE FABRICATED AND/OR ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR PROPER COORDINATION WITH WORK OF
OTHER TRADES.
13. INFORMATION AND COMPONENTS SHOWN ON DIAGRAMS OR DETAILS, BUT NOT SHOWN ON PLANS, AND VICE VERSA, MUST BE PROVIDED AS IF
EXPRESSLY REQUIRED BY BOTH.
14. EXCEPT WHERE INDICATED OTHERWISE, THE NOTATION OR DESCRIPTION OF ANY ITEM IN THE CONTRACT DOCUMENTS CARRIES WITH IT THE INSTRUCTION TO FURNISH AND INSTALL THE ITEM, WHETHER OR NOT THIS INSTRUCTION IS EXPLICITLY STATED.
15. ALL WORK SHALL BE INSTALLED SO AS MAINTAIN ANY "UL" ASSEMBLY RATINGS, FIRE RATINGS OR SMOKE BARRIER CAPABILITIES OF WALLS, PARTITIONS, FLOORS AND ROOF. SEAL AROUND AND PLACE UL RATED FIRE-STOP MATERIAL AT ANY PENETRATION OR DISTURBANCE OF SUCH
ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND CONTRACTOR.
16. COORDINATE PLACEMENT OF ALL WORK WITH OTHER TRADES. DO NOT LOCATE, POSITION OR INSTALL ANY WORK IN SUCH A WAY THAT SYSTEM COMPONENTS OR ACCESS DOORS SHALL BE INACCESSIBLE, UNUSABLE OR UN-MAINTAINABLE AFTER CONSTRUCTION IS COMPLETED. COMPLY
WITH MANUFACTURER'S MINIMUM RECOMMENDED SERVICE CLEARANCES.
17. UNLESS OTHERWISE INDICATED, ALL WORK SHALL FROM STRUCTURE ABOVE, FROM WALLS, FROM COLUMNS, OR FROM THE FLOOR. DO NOT USE THE INSTALLED WORK OF OTHER TRADES, OR WORK RELATED TO ANY SUPPORT SYSTEMS FOR SUPPORT FOR OTHER TRADES.
18. PROVIDE PIPE TRANSITIONS REQUIRED AT FIXTURE CONNECTIONS WHERE PIPE SIZES INDICATED DIFFER FROM THE FIXTURE CONNECTION SIZE.
GENERAL NOTES:
M-401
M-401
M-401
M-401
EXISTING 25 TON CHILLER
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-101
OVERALL MECHANICAL PLAN
04/18/25
TT
JH
FJ
4 21
3/32" = 1'-0"M-101
OVERALL MECHANICAL PLAN1
N
SCALE: = 1'-0"3/32"
0 11 21 3211
EXISTING 02 SUPPLY LINE UP FROM SLAB. CONNECT
NEW 1" LINE AFTER SHUT OFF AND ROUTE 1" LINE TO
OZONE GENERATOR.
PROVIDE 3/4" O3 SUPPLY LINE TYPICAL
PROVIDE OZONE
DISTRIBUTION MANIFOLD
PROVIDE 02 FILTRATION AND
REGULATING ASSEMBLY SEE
DETAIL 2/M607
PROVIDE 3/4" STAINLESS STEEL O3 SUPPLY LINE ACROSS MEZZANINE TYPICAL
C-1
C-3
C-2
M-401
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-102
OVERALL OZONE DISTRIBUTION PLAN
04/18/25
TT
JH
FJ
5 21
3/32" = 1'-0"M-102
OVERALL OZONE PLAN1
SCALE: = 1'-0"3/32"
0 11 21 3211
OZ
R1
R2
Z
R1
Z
R1
Z
R1
Z
R1
Z Z Z
R1 R1
NOTES
PROVIDE AMBIENT OXYGEN MONITOR WITH
AUDIBLE AND VISUAL ALARM.
R2
Z
O
R1
PROVIDE AMBIENT OZONE MONITOR WITH AUDIBLE
AND VISUAL ALARM. INTERLOCK WITH OZONE
GENERATOR.
PROVIDE OXIDATION REDUCTION POTENTIAL
SENSOR. MOUNT SENSOR IN LOW HEAD
OXYGENATOR HEAD BOX. INTERLOCK WITH OZONE
DOSING CONTROL SYSTEM FOR DOSING CONTROL.
PROVIDE OXIDATION REDUCTION POTENTIAL
SENSOR. MOUNT SENSOR IN TANK STAND BOX OF
THE USERS DISCRESSION. INTERLOCK WITH OZONE
DOSING CONTROL SYSTEM FOR DOSING CONTROL.
R2 R2
R2R2R2
EXISTING 25 TON CHILLER
Emilie Oakes sam ME seal
ChristopherG.Morris Line
ChristopherG.Morris Line
1 112 3 4 5 6 7 8 9 10
A
B
C
D
E
F
G
H
PLAN
NORTH
SCALE:
ROOF PLAN
3/32" = 1'-0"
M-103 PLAN
NORTH
GRAPHIC SCALE
KEYED NOTES:
1. PROVIDE SNOW / ICE GUARD AS INDICATED. LOCATED
1' BACK FROM ROOF EAVE. SEE DETAIL 4/M-605.
COORDINATE OVERALL LENGTH WITH MECHANICAL TO
PROTECT MECHANICAL EQUIPMENT AND MODULAR
BUILDING AT GRADE BELOW.
GENERAL DEMO NOTES:
A. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS
AND BRING ANY DISCREPANCIES TO THE ATTENTION OF
THE CONTRACTING OFFICER.
B. PROTECT EXISTING EQUIPMENT TO REMAIN DURING
CONSTRUCTION
C. THE BUILDING SHALL REMAIN WATERTIGHT
THROUGHOUT THE CONSTRUCTION PROCESS.
D. EXISTING ROOF PITCH IS 2:12 AND SHOULD REMAIN.
EXISTING DORMERS
U
D A
S
MECHANICAL ROOF PLAN
M-103
1 20' 20'
20'
EXISTING DORMERS
EXISTING DORMERSEXISTING DORMERS
Emilie Oakes sam ME seal
ChristopherG.Morris Line
OUTLINE OF FIBERGLASS BUILDING
VARIES
12"
6"
#4 @ 12" O.C., E.W.
2"
3"
#4 VERT. @ 12" O.C.
(6) #4 HORZ.
3/4" CHAMFER
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
OZONE GENERATOR BUILDING
M-104 7 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
'-0
13'-0"
KEYED NOTES
1 EQUIPMENT PAD, SEE 3/M-605 FOR DETAILS AND REINFORCING
2 18" X 18" EXHAUST LOUVER FOR EF-1
3 18" X 18" INTAKE LOUVER
4 LIFTING EYE , TYPE OF 4
5 PREFABRICATED FIBERGLASS EQUIPMENT BUILDING. PROVIDE COMPLETE WITH ELECTRICAL
DISTRIBUTION PANEL, WALL LOUVERS, CONVENIENCE OUTLETS, ELECTRICAL HEATER, DOORS
AND ALL OTHER MISCELLANEOUS EQUIPMENT AND DEVICES NECESSARY FOR AN OPERATIONAL
EQUIPMENT BUILDING. ADJUST SLAB DIMENSIONS TO COMPLY WITH PRE-FAB BUILDING
MANUFACTURER'S REQUIREMENTS. ALL ELECTRICAL COMPONENTS INSIDE AND WITHIN 5' OF
OPENING SHALL BE CLASS 1 DIVISION 1. PROVIDE 1/2" VERTICAL DROP AT BUILDING FOUNDATION
AND SLOPE TO DRAIN AWAY BUILDING AT 1/4" IN 12".
6 PROVIDE SUFFICIENT ANCHORAGE TO PREVENT UPLIFT OR MOVEMENT IN DESIGN WIND EVENT.
7 4' X 7' X 6" CONCRETE LANDING, REINFORCE WITH W 6X6, 2.4 X 2.4 WWF
8 STEEL SUPPORT FRAME
9 (2) 3' X 7'4" FIBERGLASS DOORS, D0012 FRAME AND HARDWARE BY BUILDING MANUFACTURER
10 SNOW AND ICE GUARD BY BUILDING MANUFACTURER
11 COORDINATE PAD LOCATION AND SIZE WITH TRANSFORMER SELECTION. PAD MUST EXTEND
MINIMUM 6-IN FROM ALL SIDES OF TRANSFORMER.
PLAN
NORTH
8'- 8"
A
PP
RO
X.
8'- 8"
, A
PP
RO
X.
9'-10" 13'- 5", APPROX.
7'-0"
4'- 0"
12'-0"
7'- 0"
SCALE:
FLOOR PLAN
NONE
M-104
SCALE:
NORTH ELEVATION
NONE
M-104
SCALE:
EAST ELEVATION
NONE
M-104
SCALE:
SOUTH ELEVATION
NONE
M-104
SCALE:
WEST ELEVATION
NONE
M-104
APPROX. FINISHED
GRADE
APPROX. FINISHED
GRADE
APPROX. FINISHED
GRADE
6"
6"
TOP OF SLAB
TOP OF SLAB
TOP OF SLAB
6"
6"
3 9
#MINIMUM DESIGN LOADS AND REQUIREMENTS IN ACCORDANCE WITH IBC 2021
LIVE FLOOR LOAD
COLLATERAL
ROOF LIVE LOAD
GROUND SNOW LOAD
ICE ACCUMULATION
WIND DESIGN DATA:
ULTIMATE WIND SPEED
WIND IMPORTANCE FACTOR
WIND EXPOSURE
EARTHQUAKE DESIGN DATA:
SEISMIC IMPORTANCE FACTOR
SS
S1
SDS
SD1
100 PSF
10 PSF
20 PSF
82 PSF
0.86 INCHES @ 55 MPH
117 MPH
1.0 C
1.0 0.25 0.06 0.2
0.09
OZ-1
UH-1
M-104
CH-1
2'-0"
2'-0"EXISTING BUILDING
EXISTING BUILDING
SCALE: 3/4"=1'-0"
0 1' 2' 4'
SCALE:
TYP. FOUNDATION DETAIL
3/4" = 1'-0"
M-104
1 11
EXISTING SUMP AND PUMPS
EXISTING BIOFILTER
EXISTING LHO
EXISTING DRUM
FILTER
CH-1
OZ-1 EF-1
UH-1
1" O2 SUPPLY LINE
PROVIDE OZONE DISTRIBUTION
MANIFOLD
02 FILTRATION AND
REGULATING ASSEMBLY SEE
DETAIL 2/M607
EXISTING 25 TON CHILLER
PROVIDE OZONE GENERATOR
BUILDING SEE SHEET M-104
C-1
EXISTING SUMP AND PUMPS
EXISTING BIOFILTER
EXISTING LHO
EXISTING DRUM
FILTER
CB-1
PROVIDE EQUIPMENT PAD,
ACOUSTAL MAT ON EXTERIOR
OF EXISTING BUILDING, AND 3
SIDED ACOUSTICAL SCREEN.
SEE SHEET M-605
C-2
EXISTING SUMP
AND PUMPS
EXISTING
BIOFILTER
EXISTING
LHO
EXISTING DRUM
FILTER
CB-2
PROVIDE EQUIPMENT PAD,
ACOUSTAL MAT ON EXTERIOR
OF EXISTING BUILDING, AND 3
SIDED ACOUSTICAL SCREEN.
SEE SHEET M-605
C-3
EXISTING SUMP
AND PUMPS
EXISTING
BIOFILTER
EXISTING
LHO
EXISTING DRUM
FILTER
PROVIDE EQUIPMENT PAD,
ACOUSTAL MAT ON
EXTERIOR OF EXISTING
BUILDING, AND 3 SIDED
ACOUSTICAL SCREEN. SEE
SHEET M-605
CB-3
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-401
ENLARGED MECHANICAL PLAN
04/18/25
TT
JH
FJ
8 21
1/4" = 1'-0"M-401
ENLARGED OZONE GENERATOR PLAN1
1/4" = 1'-0"M-401
ENLARGED BROOD 3 MECHANICAL PLAN2
SCALE: = 1'-0"
0 4 84
1/4"
1/4" = 1'-0"M-401
ENLARGED PARR MECHANICAL PLAN3
1/4" = 1'-0"M-401
ENLARGED SMOLT 2 MECHANICAL PLAN4
KEYED NOTES
PROVIDE COOLING WATER PIPING FROM CH-1 TO
OZ-1 IN ACCORDANCE WITH MANUFACTURER'S
WRITTEN RECCOMENDATIONS AND 3/M-607. PROVIDE
ALL PIPING, VALVES, ADN ALUMINUM JACKETING.
Emilie Oakes sam ME seal
ChristopherG.Morris Line
ChristopherG.Morris Line
SamEngle Line
SamEngle
NO. DATE BY DESCRIPTION
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-601
MECHANICAL SCHEDULES
04/18/25
TT
JH
FJ
9 21
C-3 15 SMOLT 2 R454B 115 50 460/3/60 29.9 40 87 x 46 x 51 11
C-2 20 PARR R454B 115 50 460/3/60 40.8 50 87 x 68 x 51 11
C-1 15 BROOD 3 R454B 115 50 460/3/60 29.9 40 87 x 46 x 51 11
MARK
NOMINAL
TONNAGE
AREA SERVED REFRIGERANT
AMBIENT
DESIGN TEMP
SUMMER (F DB)
AMBIENT
DESIGN TEMP
WINTER (F DB)
VOLTAGE/PHASE/
FREQUENCY
MCA MOCP DIMENSIONS (LxWxH) (INCH) EER
CONDENSER UNIT SCHEDULE
CB-3 15 C-3 SMOLT 2 42.8 70 50 1 150 3 18 x 16.56 x 60 <5 23.2
CB-2 20 C-2 PARR 50 70 50 1 120 3 18 x 16.56 x 80 <5 23.2
CB-1 15 C-1 BROOD 3 50 70 50 1 150 3 18 x 16.56 x 60 <5 23.2
MARK
NOMINAL
TONNAGE
ASSOCIATED
CONDENSING
UNIT
AREA SERVED
DESIGN WATER
TEMP (F)
AMBIENT INDOOR
DESIGN TEMP (F)
AMBIENT DESIGN
TEMP WINTER (F DB)
EVAPORATOR
QUANTITY
FLOW RATE PER
EVAPORATOR
(GPM)
AQUATIC
CONNECTION
(IN)
DIMENSIONS (LxWxH) (INCH)
PRESSURE
DROP AT MAX
FLOW (PSI)
IEER
CHILLER BARREL SCHEDULE
OZ-1 31.2 52.9 0-100% YES 4.5 30 50 480/3/60 49 70 42 x 37 x 83 1200 NEMA 12
MARK
OZONE OUTPUT 10%
CONCENTRATION
(PPD)
LOX SUPPLY AT 10%
CONCENTRATION PER
LB OF OZONE (SLPM)
MAX TURNDOWN
RANGE
INTEGRATED
CHILLER
COOLING LOAD
(TON)
COOLING WATER
GLYCOL %
AMBIENT DESIGN
TEMP WINTER (F DB)
VOLTAGE/PHASE/
FREQUENCY
MCA MOCP DIMENSIONS (LxWxH) (INCH)
WEIGHT
(LBS)
ENCLOSURE
OZONE GENERATOR SCHEDULE
UNIT HEATER SCHEDULE
MARK SERVES AIRFLOW CFM TEMPERATURE RISE KW FAN HP FUEL VOLT/PHASE WEIGHT (LBS) REMARKS
UH-1 OZONE GENERATOR BUILDING 530 45 °F 7.5 1/40 ELECTRIC 480/3 52 ALL
EXHAUST FAN SCHEDULE
MARK
SERVES
EXTERNAL STATIC
PRESSURE (IN. WC.)
AIRFLOW
(CFM)
FAN RPM FAN HP
ELECTRICAL
(V/C/P)
FLA
MAX
SONES
WEIGHT
(LBS)
REMARKS
EF-1 OZONE GENERATOR BUILDING .15 100 1332 .1 115/60/1 .1 3 15 SPARK B RATED
NOTES:
1. PROVIDE WITH FACTORY PROVIDED MOUNTING KIT.
2. PROVIDE WITH WALL MOUNTED THERMOSTAT SET TO 55 DEG. F.
NOTES:
1. PROVIDE WITH BACKDRAFT DAMPERS.
2. PROVIDE WITH MESH INSECT SCREEN.
3. EXHAUST FANS SHALL BE SUPPLIED WITH CORROSION PROTECTION SUITABLE FOR INSTALLATION IN DAMP ENVIRONMENTS.
4. FAN IS TO BE OF SPARK B RATED OR BETTER.
CH-1 4.5 54,000 R410A 95 10 45 55 460/3/60 14 50 x 27 x 55 800
MARK
NOMINAL
TONNAGE
CAPACITY REFRIGERANT
AMBIENT DESIGN
TEMP SUMMER (F DB)
GPM
ENTERING WATER
TEMP (F)
LEAVING WATER
TEMP (F)
VOLTAGE/PHASE/
FREQUENCY
FLA
DIMENSIONS
(LxWxH) (INCH)
WEIGHT
CHILLER SCHEDULE
NOTES:
1. PROVIDE WITH CIRCULATING PUMP, EXPANSION TANK, STRAINER, AND 30% GLYCOL..
2 SERVES OZ-1.
NOTES:
1. PROVIDE WITH TITANIUM TUBE HEAT EXCHANGERS.
2. PROVIDE WITH 316 STAINLESS STEEL BASE AND HARDWARE.
3. PROVIDE WITH MARINE GRADE ALUMINUM JACKET.
4. PROVIDE WITH THERMOWELL AND FLOW SWITCH INSTALLED ACCORDING TO MANUFACTURES INSTRUCTIONS .
5. PROVIDE WITH TEMPERATURE CONTROLLER.
NOTES:
1. PROVIDE WITH MARINE GRANDE CONDENSER COIL
2. PROVIDE WITH LOW AMBIENT MOTOMASTER KIT.
NOTES:
1. PROVIDE WITH MANUFACTURER SUPPLIED OIL FREE AIR COMPRESSER FOR VALVE ACTUATION.
2. PROVIDE WITH CLOSED LOOP GENERATOR COOLING SYSTEM (CH-1).
3. ENCLOSURE SHALL BE NEMA 4X CONSTRUCTION.
4. PROVIDE WITH AUTOMATED CONTROLLER AND PLC.
5. PROVIDE WITH AMBIENT O3 AN 02 SENSOR WITH ALARM AS INDICATED
6. PROVIDE WITH ORP SENSORS AS INDICATED FOR OZONE DOSING CONTROL.
7. PROVIDE WITH 02 FILTRATION AND REGULATING ASSEMBLY AS INDICATED.
8. PROVIDE WITH OZONE DISTRIBUTION MANIFOLD WITH 10 OUTLETS (7 FOR USE 3 SPARES).
Emilie Oakes sam ME seal
ChristopherG.Morris Line
PIPE
INSULATION
CLEVIS HANGER
WASHER (TOP & BOTTOM)
NUT (TOP & BOTTOM)
ALL THREAD ROD
INSULATION
PROTECTIVE
SHEET METAL SHIELD
PIPING
FOAM INSULATION -OR- FIRE STOP
MATERIAL (FOR FIRE RATED PARTITIONS)
PIPE INSULATION AS APPLICABLE
WALL
20 GA.
MIN.
METAL
SLEEVE
CAULK ALL JOINTS AND
SLEEVE ENDS WATERTIGHT
PIPE PENETRATION NOTES:
1. PROVIDE WITH PITCH POCKET CONSTRUCTION, ADDITIONAL FLASHING OR WEATHER CAP AS
REQUIRED FOR WATERPROOF CONSTRUCTION. DO NOT MECHANICALLY ATTACH PIPE TO
STRUCTURE IN ANY WAY.
2. SPACE BETWEEN PIPE AND SLEEVE SHALL BE FREE FROM ANY FOREIGN MATERIALS.
3. PIPE SHALL NOT CONTACT STRUCTURE AT ANY TIME. WEDGES ARE NOT TO BE USED TO MAINTAIN
PIPE POSITION.
4. PIPE MUST BE APPROXIMATELY CENTERED IN OPENING.
NOTE:
PROVIDE MIN
ANCHOR SUPPORT
SPACING EVERY 3'
VERTICALLY
FOR PIPES < 4"∅
FOR PIPES< 2"∅
TYP TO UNISTRUT
P2500 SERIES PIPE
STRAP
INSULATE AS REQD
SECURE W/APPROVED
ANCHOR TO MATCH BASE
MATERIAL AND LOAD
REQUIREMENTS
TYP TO UNISTRUT
P 1000 12 GA
CHANNEL
WALL
TYP TO UNISTRUT
P3400 SERIES PIPE
STRAP
INSULATE AS REQD
SECURE W/APPROVED
ANCHOR TO MATCH BASE
MATERIAL AND LOAD
REQUIREMENTS
TYP TO UNISTRUT
P 1000 12 GA
CHANNEL
WALL
NOTES:
PROVIDE MIN ANCHOR
SUPPORT SPACING
EVERY 3' VERTICALLY
AS REQD
PIPE
NON-INSULATED
INSULATED PIPE
HANGER RODS
NOTES:
REQUIREMENT W/SAFETY FACTOR OF 5
MEMBER APPROVED TO SATISFY LOAD
SIZE RODS, SPRING CUSHION, AND HORIZONTAL
W/OR W/OUT
PROTECTIVE
SADDLE OR SHIELD AS
REQD
UNISTRUT TYPE
SUPPORT
UNIT HEATER SHALL BE SECURED
TO WALL WITH A MINIUMIM OF TWO
BRACKETS PER MANUFACTURERS
RECOMMENDATIONS OF HEATER
AND PRE-FAB BUILDING.
TWO 5/8" BOLTS, EACH SIDE OF
FRAME WITH LOCK WASHERS
ELECTRIC UNIT HEATER
SECURED TO WALL PER
MANUFACTURER'S
GUIDELINES BASED ON WALL
TYPE
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-602
MECHANICAL DETAILS
04/18/25
TT
JH
FJ
10 21
NOT TO SCALEM-602
CLEVIS HANGER DETAIL1
NOT TO SCALEM-602
PIPE WALL PENETRATION DETAIL2
NOT TO SCALEM-602
VERTICAL WALL MOUNTED PIPING DETAIL4
NOT TO SCALEM-602
TRAPEZE HANGER DETAIL3
NOT TO SCALEM-602
UNIT HEATER WALL MOUNT DETAIL5
PROCESS WATER SUPPLY FROM SUMP
PROCESS WATER DISCHARGE TO LHO
BALANCING VALVE
ISOLATION VALVE
PROVIDE CHILLER BARREL
CHILLER BARREL SUPPLY
CONNECTION POINT
CHILLER BARREL
RETURN CONNECTION
POINT
3"ø
"ø
EXISTING SUMP AND SUMP PUMPS
EXISTING BIO FILTER
EXISTING LHO
HEAD BOX
30.0000
CONNECT TO
EXISTING 3" ACCESS
PIPE AND VENT TO
ROOF
3" LHO VENT TO EXTERIOR
SIDEWALL
CONNECT NEW OZONE
SUPPLY LINES TO EXISTING
OZONE AND OXYGEN INTAKE
BEHIND SKIRT ACCESS
RETAIN OXYGEN SUPPLY
LINES AND INTAKE
PROVIDE 3/4" OZONE SUPPLY LINE
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
M-603
MECHANICAL DETAILS
04/18/25
TT
JH
FJ
11 21
1/2" = 1'-0"M-603
TYPICAL SINGLE CHILLER BARREL SECTION1
SCALE: = 1'-0"
0 2 42
1/2"
KEYED NOTES
MODIFY EXISTING PIPING TO COMPLETE
INSTALLATION OF NEW EQUIPMENT.
NOT TO SCALEM-603
TYPICA LHO SECTION2
EXPOSED URETHANE SEALANT
3/8" (MIN) FILLET
PENETRATION PERIMETER SEAL
COVER PLATE ASSEMBLYWALL PANEL
PENETRANT
BOTTOM COVER PLATE
BOTTOM COVER PLATE INSTALLATION
URETHANE SEALANT
PENETRANT
RIVET OR SCREW
(TYP)
WALL PANEL
TOP COVER PLATE INSTALLATION
BOTTOM COVER PLATE
URETHANE SEALANT
TOP COVER PLATE
PENETRANT
WALL PANEL
RIVET OR SCREW
(TYP)
1/4" PANCAKE FASTENER
@ 8"O.C. TYP.
WALL PANEL
TRIM. CONT. @ OPENING
FRAME OPENING WITH GALV. ANGLE.
1/8" Ø RIVETS @ 8" O.C.
SEALANT TAPE CONT. BUTYL SEALANT. CONT.
CLOSED CELL SPRAY FOAM INSULATION:
TIGER FOAM E-84 FIRE RATED SPF CLASS 1
SPRAY FOAM SYSTEM. OR APPROVED EQUAL
PAINT EXTERIOR OF INSULATION WITH ACRYLIC
ELASTOMERIC PAINT EQUAL TO: SHERWIN-WILLIAMS:
1CT LOXON MASONRY PRIMER 1 CT CONFLEX HIGH
BUILD
BACKER SHEET EQUAL TO: INSULWEB POLYPROPYLENE
FABRIC AS MANUFACTURED BY HANES ENGINEERING
MATERIALS.
WRAP PENETRANT IN BACKER SHEET TO PREVENT
ADHESION OF INSULATION. THIS IS TO ALLOW FOR
MOVEMENT.
EXPOSED URETHANE SEALANT
3/8" (MIN) FILLET
PENETRATION PERIMETER SEAL
COVER PLATE ASSEMBLY
WALL PANEL
BOTTOM COVER PLATE
BOTTOM COVER PLATE INSTALLATION
URETHANE SEALANT
PENETRANT
RIVET OR SCREW
(TYP). @ 6"O.C.
WALL PANEL
TOP COVER PLATE INSTALLATION
BOTTOM COVER PLATE
URETHANE SEALANT
TOP COVER PLATE
PENETRANT
WALL PANEL
RIVET OR SCREW
(TYP)
SINGLE PENETRATION LIMITED IN-LINE PENETRATIONS
NOTE: SEE ELEVATION FOR NUMBER AND
APPROXIMATE SIZE OF PENETRATIONS.
NOTE: WATERTIGHT SEAL REQUIRED AT ALL
PENETRATIONS
PENETRANT. SEE ELEVATIONS FOR APPROXIMATE SIZE AND
TYPE. FIELD VERIFY
2"
5"@ 3" ANGLE GIRT.
10"@ 8" CHANNEL GIRT
NEW 1" 22GA Z FURRING, SPACED 16" O.C. MAX,
SECURE WITH MAXIMUM 2 ANCHORS
UNISTRUT FOR MOUNTING WALL ITEMS
(CONDUIT, ELECTRICAL BOXES,
CONTROL PANELS, ETC.)
INSIDEOUTSIDE
SCALE:
MULTIPLE PENETRATION THROUGH WALL DETAIL
NONE
M-604
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
MECHANICAL DETAILS
M-604 12 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
SCALE:
TYPICAL UNITSTRUT MOUNTING DETAIL
NONE
M-604
SCALE:
TYPICAL SINGLE OR LIMITED PENETRATION DETAIL
NONE
M-604
STANDING SEAM METAL ROOF
INSULATION
CLAMPING RING FASTENERS SET IN MASTIC
3" VENT
STAINLESS STEEL BAND CLAMP
PREFABRICATED ROOF PENETRATION BOOT
SEALANT
BED OF MASTIC
FACE OF EXISTING BUILDING
EQUIPMENT SLAB SEE
DETAIL THIS SHEET
OUTLINE OF MECH.
EQUIPMENT
SCALE:
MECHANICAL SCREEN PLAN
NONE
M-605
1'- 0"
4"
B 2'-
0"
4"
2'-0" A 2'-0"
A + 2'-0" OR B + 2'-0"
SCALE:
MECHANICAL SCREEN ELEVATION
NONE
M-605
6" 4'-
0" 1'-
0" 3'-
6"
1'-4"
APPROX FINISHED GRADE
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
MECHANICAL DETAILS
M-605 13 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
12" TYP
NON-SLIP 'BROOMED' FINISH
(4)#4 CONTINUOUS
#4 12" OC MAX E.W.
COMPACTED MATERIAL (95%
STANDARD PROTECTOR)
BROAD SWEEP CONDUIT
AS REQ'D
TURNDOWN ALL
SIDES, TYP.
#4 STIRRUP @ 12" O.C.
3/4" CHAMFER
6" THICK
PAD MINIMUM
1'
4"
KEYED NOTES
1. 4X4 COMPOSITE POST
2. COMPOSITE SCREEN PANEL
3. STAINLESS STEEL CLIP TO ALLOW REMOVAL OF PANEL, TYPICAL ALL
PANELS
4. COMPOSITE FINAL
5. 1" ACOUSTICAL MAT ATTACHED TO WALL PANELS AS RECOMMENDED
BY MANUFACTURER 135" X 54"
6. 16" X 42" CONCRETE FOOTING
7. SLOPE TO DRAIN
SCALE:
EQUIPMENT SLAB DETAIL
NONE
M-605
FINISHED GRADE
ANCHOR BARS AS
REQ'D BE EQUIPMENT
(4) #4 VERT
(4) #4 TIES
SNOW/ICE CLIP BETWEEN
ROOF RIBS (BEYOND)
CONTINUOUS CROSSMEMBER
SNOW/ICE GAURDS
PROVIDE COLOR STRIP
INSERT FROM METAL
ROOF COIL STOCK
METAL CLAMP
ONE PER ROOF RIB
STANDING SEAM
STANDING ROOF PANEL
SCALE:
SNOW AND ICE GAURD DETAIL
NONE
M-605
NOTE: SEE SCHEDULE FOR DIMENSION
2 TYP.
1"
SCALE:
ROOF VENT DETAIL
NONE
M-605
LEGEND
PID PROCESS INSTRUMENTATION DIAGRAM
V VALVE
AIT ANALYSIS INDICATING TRANSMIT
PRV PRESSURE REGULATING VALVE
PIT PRESSURE INDICATING TRANSMITTER
F FILTER
S SOLENOID VALVE
PSW PRESSURE SAFETY VALVE
PI PRESSURE INDICATOR
FI FLOW INDICATOR
ODU OZONE DESTRUCT
S SOLENOID VALVE
TT TEMPERATURE TRANSMIT
EX HEAT EXCHANGER
HMI HUMAN MACHINE INTERFACE
PT PRESSURE TRANMIT
FT FLOW TRANSMIT
M MASS FLOW METER
FI ROTOMETER
MFC MASS FLOW CONTROLLER
RAS RECIRCULATING AQUICULTURE SYSTEM
PDM PROCESS DEVICE MANAGER
CWS CHILL WATER SUPPLY
CWR CHILL WATER RETURN
SV SOLENOID VALVE
V
DRAIN
EX
FT
V
V
TT
PI
V
V
PRV
TT
PI
V V
HMI
TT
AIT
M
FT
V
PT
V
PT
F
FI
O3
AIT
ODU
WD
VWD
SW
S
PRV
PI PSW
S
S
O2
O3
CWR
CWS
DRAIN
AIT
S
SV
S
SV
FT
TT
CV
3/4" TUBE
CWS INLET
3/4" TUBE
CWR OUTLET
ENCLOSURE
TEMP
ENCLOSURE
AMBIENT O3
3/4" TUBE
O2 INLET
3/4" TUBE
OZONE OUTLET
1/4" TUBE
BMT VENT
DRAIN PAN
1/2" NPT
VENT
PDM COMMAND FROM RAS SYSTEMS
1/4" TUBE
OXYGEN
VENT
1/4" TUBE
OXYGEN
VENT
1/4"COMPRESSED AIR FROM
MANUFACTURER SUPPLIED
COMPRESSOR
1/2" HOSE CONDENSATE
DRAIN TO EXTERIOR OF
BUILDING
OZONE GENERATOR
(OZ-1)
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
OZONE GENERATOR PID
M-606 14 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
SCALE:
OZONE GENERATOR PID
N.T.S.
M-606
O2 CW
S CW
RLOX SUPPLY
FROM CUSTOMER
1" SS
FLANGE
1" SS
FLANGE
3/4" TUBE
CH-1
OZONE GENERATOR
OZONE
DISTRIBUTION
SYSTEM
3/4" O3
TUBEO2
COOLING WATER
COOLING WATER
1/2" HOSE CONDENSATE
DRAIN TO EXTERIOR OF
BUILDING
1/4" TUBE O2 PURGE
COMPRESSED AIR
FROM
MANUFACTURER
SUPPLIED
COMPRESSOR
1" PIPE
1" PIPE
1" P
IP
E
1" P
IP
E
3/4" TUBE
PRV BVBV F BVPIT PITPIT AIT
OXYGEN
FILTER
1" FLANGED OXYGEN
INLET FROM O2 MAIN
1" LOX SUPPLY
1" FLANGED OXYGEN
OUTLET TO OZONE
GENERATOR
1/4" DRAIN
LEGEND
BV BALL VALVE
AIT ANALYSIS INDICATING TRANSMIT
PRV PRESSURE REGULATING VALVE
PIT PRESSURE INDICATING TRANSMITTER
F FILTER
CV BV
BV
STR BV
BV
BV
BV
CH-1
DRAIN
FILL
1" FLANGED CHILLED WATER
RETURN FROM OZONE
GENERATOR
1" FLANGED CHILLED WATER
RETURN TO OZONE
GENERATOR
LEGEND
BV BALL VALVE
STR STRAINER
CV CHECK VALVE
V PRESSURE INDICATING TRANSMITTER
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
OZONE GENERATOR DIAGRAMS
M-607 15 2204/18/2025
THT
JEH
AEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-E
XXX
XXX
XXX
XXX
SCALE:
OZONE GENERATOR DIAGRAM
N.T.S.
M-607 SCALE:
LOX FILTRATION AND REGULATING DIAGRAM
N.T.S.
M-607
SCALE:
OZONE CHILLER DIAGRAM
N.T.S.
M-607
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
MECHANICAL DIAGRAMS
M-608 16 2204/18/2025
THT
JEH
FEJ NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
25 SALMON FARM RD.
FRANKLIN, ME 04634
XXX
3724-M
XXX
XXX
XXX
XXX
SCALE:
BROOD 3
CHILLING SYSTEM DIAGRAM
NTS
M-608 SCALE:
PARR
CHILLING SYSTEM DIAGRAM
NTS
M-608
SCALE:
SMOLT 2
CHILLING SYSTEM DIAGRAM
NTS
M-608
AIR COOLED
CHILLER (C-1)
OUTSIDEINSIDE WATER
TREATMENT BAY
EXISTING SUMP
EXISTING RECIRCULATING PUMP
EXISTING LHO
ISOLATION VALVE
(TYPICAL OF (2))
BALANCING VALVE
REFRIGERANT SUPPLY AND RETURN
DX CHILLER BARREL
WITH CONTROLLER
AIR COOLED
CHILLER (C-3)
OUTSIDEINSIDE WATER
TREATMENT BAY
EXISTING SUMP
EXISTING RECIRCULATING PUMP
EXISTING LHO
ISOLATION VALVE
(TYPICAL OF (2))
BALANCING VALVE
REFRIGERANT SUPPLY AND RETURN
DX CHILLER BARREL
WITH CONTROLLER
AIR COOLED
CHILLER (C-2)
OUTSIDEINSIDE WATER
TREATMENT BAY
EXISTING SUMP
EXISTING RECIRCULATING PUMP
EXISTING LHO
ISOLATION VALVE
(TYPICAL OF (2))
BALANCING VALVE
REFRIGERANT SUPPLY AND RETURN
DX CHILLER BARREL
WITH CONTROLLER
Emilie Oakes sam ME seal
ChristopherG.Morris Line
NOTE:
1. NOT ALL ABBREVIATIONS SHOWN WILL BE USED ON THIS PROJECT.
A OR AMP
ACC
AC
AC
AF
AFF
AFG
AHU
AIC
AL
AM
ASYM
AT
ATS
AUTO
AWG
B
BC
BCW
BFF
BFG
BLDG
BMGB
C
CAT
CB
CCT
CCTV
CFCI
CH
CHWCP
CHWP
CHWSP
CKT
CMH
CMS
CP
CPT
CRAC
CRI
CT
CT
CU
CWP
D
DC
DF
DH or DUH
DHWCP
DISC
DOAS
DPST
DPDT
DSCU
DSHP
DSS
DWBP
DX
EC
ECB
EF
ELEC
EMH
EMT
E or EMER
EPA
EQUIP
ERV
ERU
EXIST or EX
EUH
EXP
EWC
EWH
F
FACP
FCU
FLEX
FWE
G OR GND
GFGI
GFI
GRS
GUH
GWH
H or HT
HAC
HOA
HP
HP
HT
HVU
HWCP
HWP
HWRP
HWSP
AMPERE(S)
AIR COOLED CHILLER
ALTERNATING CURRENT
AIR COMPRESSOR / AIR CURTAIN
AMP FRAME
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AIR HANDLING UNIT
AMPERE INTERRUPTING CAPACITY
ALUMINUM
AMMETER
ASYMMETRICAL
AMP TRIP
AUTOMATIC TRANSFER SWITCH
AUTOMATIC
AMERICAN WIRE GAUGE
BOILER
BRANCH CONTROLLER
BARE COPPER WIRE
BELOW FINISHED FLOOR
BELOW FINISHED GRADE
BUILDING
BUILDING MASTER GROUNDING BUSBAR
CONDUIT
CATEGORY
CIRCUIT BREAKER
CORRELATED COLOR TEMPERATURE
CLOSED CIRCUIT TELEVISION
CONTRACTOR FURNISHED CONTRACTOR INSTALLED
CHILLER
CHILLED WATER CIRCULATING PUMP IN A PRIMARY-SECONDARY SYSTEM
CHILLED WATER PUMP
CHILLED WATER SUPPLY PUMP IN A PRIMARY-SECONDARY SYSTEM
CIRCUIT
COMMUNICATIONS MANHOLE
COMBINATION MOTOR STARTER
CONDENSATE PUMP
CONTROL POWER TRANSFORMER
COMPUTER ROOM AC UNIT
COLOR RENDERING INDEX
CURRENT TRANSFORMER
COOLING TOWER
COPPER OR CONDENSING UNIT
CONDENSER WATER PUMP
DEPTH
DIRECT CURRENT
DESTRATIFICATION FAN
DUCT HEATERS
DOMESTIC HOT WATER CIRCULATING PUMP
DISCONNECT SWITCH
DEDICATED OUTSIDE AIR SYSTEM (UNIT)
DOUBLE POLE SINGLE THROW
DOUBLE POLE DOUBLE THROW
DUCTLESS SPLIT CONDENSING UNIT (POWERS THE DSS INDOOR UNIT)
DUCTLESS SPLIT HEAT PUMP (POWERS THE DSS INDOOR UNIT)
DUCTLESS SPLIT SYSTEM (INDOOR UNIT)
DOMESTIC WATER BOOSTER PUMP
DIRECT EXPANSION (DX) COOLING COIL
EMPTY CONDUIT
ENCLOSED CIRCUIT BREAKER
EXHAUST FAN
ELECTRICAL
ELECTRICAL MANHOLE
ELECTRICAL METALLIC TUBING
EMERGENCY
EFFECTIVE PROJECTED AREA
EQUIPMENT
ENERGY RECOVERY VENTILATOR
ENERGY RECOVERY UNIT
EXISTING
ELECTRIC UNIT HEATER
EXPLOSION PROOF
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FUSE
FIRE ALARM CONTROL PANEL
FAN COIL UNIT
FLEXIBLE
FURNISHED WITH EQUIPMENT
GROUND
GOVERNMENT FURNISHED GOVERNMENT INSTALLED
GROUND FAULT INTERRUPTER
GALVANIZED RIGID STEEL CONDUIT
GAS UNIT HEATER
GAS WATER HEATER
HEIGHT
HEATED AIR CURTAIN
HAND-OFF AUTOMATIC
HORSE POWER
HEAT PUMP (OUTDOOR PORTION OF SPLIT SYSTEM HEAT PUMP, USE CU FOR
STANDARD DX OUTDOOR UNIT)
HEAT TRACKING
HEATING/VENTILATING UNIT
HEATING WATER CIRCULATING PUMP IN A PRIMARY-SECONDARY SYSTEM
HEATING WATER SUPPLY IN A PRIMARY-ONLY SYSTEM
HOT WATER RECIRCULATION PUMP
HEATING WATER SUPPLY PUMP IN A PRIMARY-SECONDARY SYSTEM
ELECTRICAL ABBREVIATIONS
HWUH
HZ
IDS
IMC
IRH
J OR JB
K
KAIC
KCM OR KCMIL
KEF
KH
KV
KVA
KW
KWHR
L
LA
LAN
LAV
LM
LTG
MAU
MAX
MCA
MCB or MB
MCC
MGB
MH
MIN
MLO
MOD
MT or MTD
MRS
N
NEC
NEMA
NFPA
NC
NESC
NL
NO
NTS
P
PA
PBB
PDU
PF
PH
PIU
PMT
PNL
PTAC
PVC
RBB
RECEPT or RECP
RF
RH
RMC
RMS
RTU
RVNR
SA
SBB
SCCR
SD
SF
S/N
SP
SPD
SPDT
SPEC
SPST
SWBD
SWGR
TEBC
TMGB
TOL
TP
TYP
U
UH
UG
UIO
UL
UTP
V
VA
VAV
VEF
VM
VRF
W
WC
WEF
WH
WHDM
WSHP
WP
WPIU
XFMR
Z
HOT WATER UNIT HEATER
HERTZ
INTRUSION DETECTION SYSTEM
INTERMEDIATE METAL CONDUIT
INFRARED HEATER
JUNCTION BOX
KILO
THOUSAND AMPERE INTERRUPTING CAPACITY
THOUSAND OF CIRCULAR MILS
KITCHEN EXHAUST FAN
KITCHEN HOOD
KILOVOLT
KILOVOLT-AMPERES
KILOWATT
KILOWATT-HOUR
LENGTH
LIGHTNING ARRESTOR
LOCAL AREA NETWORK
LAVATORY
LOCKHEED MARTIN
LIGHTING
MAKE-UP AIR UNIT
MAXIMUM
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAIN GROUND BAR
MANHOLE or MOUNTING HEIGHT
MINIMUM
MAIN LUGS ONLY
MOTOR OPERATED DAMPER
MOUNT or MOUNTED
MOTOR RATED SWITCH
NEUTRAL
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION
NATIONAL FIRE PROTECTION ASSOCIATION
NORMALLY CLOSED
NATIONAL ELECTRICAL SAFETY CODE
NIGHT LIGHT
NORMALLY OPEN
NOT TO SCALE
POLE(S) or PUMP
PUBLIC ADDRESS
PRIMARY BONDING BUSBAR
POWER DISTRIBUTION UNIT
POWER FACTOR
PHASE
VAV TERMINAL UNIT WITH PARALLEL OR SERIES FAN (PRIMARY INDUCTION UNIT)
PAD MOUNTED TRANSFORMER
PANEL OR PANELBOARD
PACKAGED THRU-WALL AIR CONDITIONER
POLYVINYL CHLORIDE
RACK BONDING BUSBAR
RECEPTACLE
RETURN FAN
RADIANT HEATERS (ELECTRIC)
RIGID METAL CONDUIT
ROOT MEAN SQUARE
ROOF TOP UNIT
REDUCED VOLTAGE NON-REVERSING
SURGE ARRESTOR
SECONDARY BONDING BUSBAR
SHORT CIRCUIT CURRENT RATING
SMOKE DAMPER
SUPPLY FAN
SOLID NEUTRAL
SUMP PUMP
SURGE PROTECTIVE DEVICE
SINGLE POLE DOUBLE THROW
SPECIFICATIONS
SINGLE POLE SINGLE THROW
SWITCHBOARD
SWITCHGEAR
TELECOMMUNICATIONS EQUIPMENT BONDING CONDUCTOR
TELECOMMUNICATIONS MAIN GROUNDING BUSBAR
THERMAL OVERLOAD
TWISTED PAIR
TYPICAL
URINAL
UNIT HEATER
UNDERGROUND
UNLESS INDICATED OTHERWISE
UNDERWRITERS LABORATORY
UNSHIELDED TWISTED PAIR
VOLTS
VOLT AMPERES
VAV TERMINAL UNIT
VEHICLE EXHAUST FAN
VOLTMETER
VARIABLE REFRIGERANT FLOW SYSTEM
WATTS or WIRE or WIDTH
WATER CLOSET
WELDING EXHAUST FAN
WATER HEATER
WATTHOUR DEMAND METER
WATER SOURCE HEAT PUMP
WEATHERPROOF
WEATHERPROOF IN USE
TRANSFORMER
IMPEDANCE
1. THE WORK MUST CONFORM WITH ALL REQUIREMENTS OF:
• NFPA 70, NATIONAL ELECTRICAL CODE (NEC) (2023)
• NFPA 101, LIFE SAFETY CODE (2024)
• ARS 242.1M, ARS FACILITIES DESIGN STANDARDS (2024)
• ASHRAE 90.1, ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS (2019)
*CRITERIA AND STANDARDS LISTED ALSO INCLUDE SPECIFIED STANDARDS AND RELATED SECTIONS AS PART OF THE DESIGN.
2. MINIMUM RACEWAY SIZE MUST BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL RATIO TO LESS THAN 40% FULL.
3. THE ELECTRICAL CONTRACTOR MUST CAREFULLY COORDINATE WORK WITH OTHER TRADES THROUGH THE GENERAL CONTRACTOR AND MUST BE RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE FOR RECESSED LUMINAIRES AND CORRECT ROUGH-IN
LOCATIONS OF ELECTRICAL CONNECTIONS.
4. ALL FEEDERS AND BRANCH CIRCUITS MUST INCLUDE A GREEN INSULATED GROUND CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR.
5. EXISTING ELECTRICAL WORK (NOT SHOWN) MUST REMAIN, UNLESS INDICATED OTHERWISE. SHOULD ANY EXISTING ELECTRICAL POWER, LIGHTING OR AUXILIARY CIRCUIT, FEEDER OR EQUIPMENT BE SEVERED, DISCONNECTED OR DELETED IN THE PROCESS OF CONSTRUCTION OR REMODELING WHICH IS DONE AS A RESULT OF CONTRACT PLANS AND SPECIFICATIONS, AND UNLESS SPECIFICALLY DESIGNATED BY THE DRAWINGS TO BE DELETED, THEN SAID CIRCUIT OR FEEDER MUST BE RESTORED TO WORKING CONDITION. THE RESTORATION MUST INCLUDE RE-ROUTING, RELOCATION, RECONNECTION OR REPLACEMENT AS MAY BE REQUIRED BY THE NEW WORK. ANY SUCH WORK REQUIRED MUST BE INCLUDED IN THE CONTRACT AND NO EXTRA COMPENSATION WILL BE GRANTED.
6. NEW WORK MUST BE MADE TO TIE INTO THE EXISTING IN A UNIFORM MANNER, SIMILAR ITEMS OF NEW WORK MUST BE CHECKED AGAINST EXISTING WORK.
7. REFER TO ONE-LINE DIAGRAMS, SCHEDULES AND RISER DIAGRAMS FOR CONDUCTOR AND CONDUIT SIZES NOT SHOWN ON PLANS.
8. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS ALL APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.
9. DEMOLISH IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE CONTRACTOR TO DISCONNECT EQUIPMENT FROM ALL CONNECTIONS, REMOVE FROM THE OWNER'S SITE, AND DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND ORDINANCES. COST OF DISPOSAL IS ENTIRELY THE CONTRACTOR'S RESPONSIBILITY.
10. ALL CONDUCTORS ARE COPPER UNLESS SPECIFICALLY NOTED AS ALUMINUM.
11. CONTRACTOR MUST FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE PROCUREMENT OF ANY MATERIALS AND DEVELOPMENT
OF ANY SHOP DRAWINGS OR SUBMITTALS.
13. ALL EQUIPMENT PADS FOR INTERIOR ELECTRICAL EQUIPMENT MUST BE FLUSH WITH FRONT SIDE OF EQUIPMENT AND EXTEND AT LEAST 2” BEYOND THE
FOOTPRINT OF THE EQUIPMENT ON ALL OTHER SIDES.
ELECTRICAL GENERAL NOTES:
NO. DATE BY DESCRIPTION
REVISIONS
U S D A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
E-001
ELECTRICAL GENERAL NOTES
04/18/25
TT
EH
CG
david ME seal
LA-1
LA-1
ELECTRICAL LEGEND
1. ALL EQUIPMENT AND DEVICES ARE TO BE FLUSH MOUNTED UNLESS
OTHERWISE NOTED.
2. DEVICES NOTED AS "GFCI" MUST BE GROUND FAULT CIRCUIT
INTERRUPTING DEVICES.
3. DEVICES NOTED AS "WP" MUST BE GFI AND WEATHERPROOF.
4.
DEVICES NOTED AS "DL" MUST BE RATED FOR DAMP LOCATION.5.
DEVICES NOTED AS "NL" MUST BE NIGHT LIGHTS. PROVIDE
UNSWITCHED POWER TO FIXTURE.
6.
DEVICES NOTED AS "WG" MUST BE PROVIDED AND INSTALLED WITH
A WIRE GUARD.
7.
DEVICES NOTED AS "TR" MUST BE TAMPER RESISTANT.8.
PROVIDE UNSWITCHED POWER TO EMERGENCY BATTERY
PACKS.
PE
DUPLEX RECEPTACLE, NEMA 5-20R, MOUNTED 18" A.F.F. TO
CENTERLINE OF BOX UNLESS NOTED OTHERWISE.
CONTACTOR.
PHOTOCELL.
CEILING MOUNTED JUNCTION BOX.
WALL MOUNTED JUNCTION
BOX.
FLEXIBLE CONNECTION TO
EQUIPMENT.
CONDUIT AND WIRING RECEPTACLESLEGEND GENERAL NOTES MISCELLANEOUS
CONDUCTORS IN CONDUIT CONCEALED WITHIN WALL OR
CEILING. TIC MARKS INDICATE NUMBER OF
CONDUCTORS. THE EQUIPMENT GROUNDING CONDUCTOR
IS NOT SHOWN, BUT MUST BE PROVIDED. SIZE THE
EQUIPMENT GROUNDING CONDUCTOR AND THE CONDUIT
PER THE NEC. THE ABSENCE OF TIC MARKS SIGNIFIES
THAT TWO CONDUCTORS PLUS AN EQUIPMENT GROUNDING
CONDUCTOR SHOULD BE PROVIDED. FOR EXAMPLE, THE
MARKINGS TO THE LEFT SIGNIFY THAT THREE
CONDUCTORS PLUS AN EQUIPMENT GROUNDING
CONDUCTOR SHOULD BE PROVIDED.
CONDUCTORS IN CONDUIT CONCEALED BELOW GRADE OR
FLOOR. TIC MARKS INDICATE NUMBER OF CONDUCTORS.
THE EQUIPMENT GROUNDING CONDUCTOR IS NOT
SHOWN, BUT MUST BE PROVIDED. SIZE THE EQUIPMENT
GROUNDING CONDUCTOR AND THE CONDUIT PER THE
NEC. THE ABSENCE OF TIC MARKS SIGNIFIES THAT TWO
CONDUCTORS PLUS AN EQUIPMENT GROUNDING
CONDUCTOR SHOULD BE PROVIDED. THE MARKINGS TO
THE LEFT SIGNIFY THAT THREE CONDUCTORS PLUS AN
EQUIPMENT GROUNDING CONDUCTOR SHOULD BE
PROVIDED.
THE TEXT INSIDE THE ARC INDICATES THE AWG SIZE OF
THE CONDUCTORS THAT MUST BE RUN IN THE CONDUIT.
THE ABSENCE OF TEXT SIGNIFIES THAT THE
CONDUCTORS SHOULD BE #12 AWG.
CIRCUITRY RUN IN STRAIGHT LINE SEGMENTS SIGNIFIES
EXPOSED SURFACE-MOUNTED RACEWAY (SEE
SPECIFICATIONS).
HOMERUN TO PANELBOARD. ARC DENOTES CONCEALED
CIRCUITRY. TEXT DENOTES PANELBOARD NAME WITH
CIRCUIT NUMBER. DEVICES HAVING CIRCUIT NUMBERS
LOCATED BESIDE THEM MAY NOT SHOW THE CIRCUIT
NUMBERS AT THE HOMERUN ARROWS.
PARTIAL HOMERUN TO PANELBOARD. COMBINE ALL
PARTIAL HOMERUNS THAT ARE ON THE SAME CIRCUIT IN
A JUNCTION BOX PRIOR TO ENTERING THE PANELBOARD.
LOW VOLTAGE CONDUCTORS USED FOR MOTION DETECTOR
CIRCUITRY. SEE MANUFACTURER'S RECOMMENDATIONS
FOR CONDUCTOR REQUIREMENTS.
C
J
J
DEVICES NOTED AS "WPIU" MUST BE GFI AND WEATHERPROOF IN USE.
9.
LONG TIC MARK IDENTIFIES CONDUCTOR. SHORT TICK MARK
IDENTIFIES NEUTRAL. HOOKED TIC MARK IDENTIFIES GROUND.
MECHANICAL ELECTRICAL
CONNECTION. TOP VALUE
REPRESENTS VOLTAGE AND PHASE.
BOTTOM VALUE IS IDENTIFIER.
120 V 1P
M1
GROUND FAULT CIRCUIT INTERRUPTOR DUPLEX RECEPTACLE, NEMA
5-20R, MOUNTED 18" A.F.F. TO CENTERLINE OF BOX UNLESS NOTED
OTHERWISE.
GFCI
NO. DATE BY DESCRIPTION
REVISIONS
U S D A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
E-002
ELECTRICAL LEGEND
04/18/25
TT
EH
CG
C-2
480 V 3P C-3
480 V 3P
EX-C
480 V 3P
EX-C
480 V 3P
C-1
480 V 3P
CH-1
480 V 3P
UH-1
480 V 3P
EF-1
120 V 1P
OZ-1
480 V 3P
RPB
DP-4
P-D
P-G1
P-G2
P-C
P-MM
P-NM
P-H L-L
P-A2
P-A1
P-J1
P-J2
MDP
DT-1
DP-1
P-H1
MDP-2-7,9,11
MDP-2
ATS-2
GEN-1
P-H2-8,10,12
P-H2-7,9,11
P-H2
MDP-2-8,10,12
P-H1-1,3,5
P-H1-7,9,11
P-H2-13,15,17
P-H2-1,3,5
P-Q2 QT-1QT-1-1
MDP-2-2,4
P-H2-2,4,6
P-Q2-1
P-H2-14,16,18
NO. DATE BY DESCRIPTION
REVISIONS
U S D A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
E-101
POWER PLAN
04/18/25
TT
EH
CG
3/32" = 1'-0"E-101
POWER PLAN1
SCALE: = 1'-0"3/32"
0 11 21 3211
N
X
1. PANEL IS PROPOSED IN ANOTHER PROJECT. IT IS SHOWN
FOR LOAD AND PLANNING PURPOSES.
2. AN ADDITIONAL 100 AMPS OF LOAD IS ANTICIPATED TO BE
ADDED TO THIS PANEL IN ANOTHER PROJECT.
3. PROVIDE NEW ELECTRIC PANEL. SEE E-601 FOR MORE
DETAILS.
4. PREFABRICATED FIBERGLASS ENCLOSURE.
• PROVIDE 125A 120/240V SERVICE AND 16 CIRCUIT
BREAKER PANEL.
• INTERIOR AND EXTERIOR LIGHTING PROVIDED BY
ENCLOSURE MANUFACTURER. PROVIDE
CONDUIT/CONDUCTORS, SINGLE POLE SWITCH, AND
INSTALL LIGHT FIXTURES.
• NOTE: ENCLOSURE INTERIOR AND ALL AREAS WITHIN
5-FT OF ENCLOSURE OPENINGS ARE CLASS I DIV I.
COORDINATE MATERIALS AND INSTALLATION METHOD
WITH SPACE REQUIREMENTS.
5. LOCATE MINIMUM 5-FT FROM ANY OPENINGS IN CLASSIFIED
SPACE.
KEYED NOTES
1/4" = 1'-0"E-101
OZ-1 BUILDING DETAIL2
UT-1
SCALE: = 1'-0"
0 4 84
1/4"
Emilie Oakes david ME seal
ChristopherG.Morris Line
GRADE OR
SLAB ON GRADE
USE SCHEDULE 40
POLYVINYL CHLORIDE (PVC)
CONDUIT FOR CIRCUITS
UNDERGROUND. USE PVC-COATED
GALVANIZED RIGID STEEL
ELBOWS.
USE GALVANIZED RIGID
STEEL OR INTERMEDIATE
METAL CONDUITS WHERE
CIRCUITS ARE EXPOSED TO
ABRASION.
USE PVC-COATED GALVANIZED
RIGID STEEL CONDUIT FOR ALL
VERTICAL RUNS EXTENDING 6"
ABOVE GRADE.
USE INTERMEDIATE METAL
CONDUITS OR ELECTRICAL
METALLIC TUBING FOR ALL
BRANCH CIRCUITS, FEEDERS,
AND AUXILIARY CIRCUITS
REQUIRING 1-1/4" NOMINAL
TRADE SIZE OR LARGER IN
DRY LOCATIONS.
UNDERGROUND
CONDUIT.
24"
MINIMAL
USE GALVANIZED RIGID
STEEL CONDUITS WHERE
CIRCUITS ARE RUN ABOVE
GROUND EXPOSED TO
WEATHER.
SERVICES, CONDUITS FOR
PRIMARY CONDUCTORS, AND
CONDUITS RUN UNDER
ROADWAYS MUST BE
BURIED NO LESS THAN 24"
DEEP.
6"
USE PVC-COATED
GALVANIZED RIGID STEEL
ELBOWS.
USE PVC-COATED GALVANIZED
RIGID STEEL CONDUIT FOR ALL
VERTICAL RUNS EXTENDING 6"
ABOVE GRADE.
6"
NOTE: GRS & IMC CONDUIT
THREADS MUST BE
GALVANIZED AFER CUTTING.
NOTE: GALVANIZED RIGID STEEL CONDUIT
COATED WITH TWO COMPLETE COATS OF
ASPHALTIC OF BITUMINOUS PAINT MAY
BE USED IN LIEU OF PVC-COATED
GALVANIZED RIGID STEEL CONDUITS.
ELECTRICAL CIRCUIT SCHEDULE
LOAD NAME VOLTAGE PHASE PANEL CIRCUIT NUMBER APPARENT LOAD WIRE SIZE
C-1 480 V
C-2
C-3
C-4
BREAKER
C-6
CH-1
EF-1
MDP
MECHANICAL
P-Q2
QT-1
UH-1
480 V
480 V
480 V
480 V
480 V
120 V
480 V
480 V
240 V
480 V
480 V
P-H2
P-H2
P-H2
P-H1
P-H1
P-H2
P-Q2
MDP-2
P-H2
QT-1
MDP-2
P-H2
7,9,11
8,10,12
13,15,17
7,9,11
1,3,5
1,3,5
43231 VA
33919 VA
50547 VA
33919 VA
16627 VA
120 VA
798106 VA
40737 VA
1060 VA
1060 VA
9311 VA
70A
70A
60A
80A
60A
30A
20A
1000A
20A
3-#4, 1-#4, 1-#8
(3) 3-#400, 1-#400, 1-#3
2-#12, 1-#12, 1-#12
1,3,5
14,16,18
2,4
2,4,6
43231 VA
3-#4, 1-#4, 1-#8
3-#6, 1-#6, 1-#10
3-#6, 1-#6, 1-#10
3-#4, 1-#4, 1-#8
70A3-#4, 1-#4, 1-#8
20A2-#12, 1-#12, 1-#12
20A3-#12, 1-#12, 1-#12
3-#12, 1-#12, 1-#12
1-#12, 1-#12, 1-#12
ELECTRICAL CIRCUIT SCHEDULE
LOAD ID CIRCUIT VOLTAGE NUMBER OF
POLES
MCA MOCP
C-1
C-2
C-3
CH-1
APPARENT
POWER
EF-1
EX-C
EX-C
OZ-1
UH-1
480V 3
61A
41A
20A
1A
52A
52A
49A
11A
33919VA
50547VA
33919VA
16627VA
120VA
43231VA
43231VA
40737VA
50A
70A
41A
80A
50A
1A
30A
9311VA1A
70A
70A
DISCONNECT
3P60A
3P100A
3P60A
3P100A
3P100A
P-H2-13,15,17
P-H1-7,9,11
P-H1-1,3,5
P-H1-1,3,5
P-Q2-1
P-H2-8,10,12
P-H2-7,9,11
P-H2-14,16,18
P-H2-2,4,6
480V
480V
480V
120V
480V
480V
480V
480V
NO. DATE BY DESCRIPTION
REVISIONS
U S D A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
E-501
SCHEDULES AND DETAILS
04/18/25
TT
EH
CG
N.T.SE-501
1 CONDUIT DETAIL
Emilie Oakes david ME seal
ChristopherG.Morris Line
PANEL
P-NM
600A
MLO
480Y/277V 3P 4W
PANEL
P-H1 225A
MCB
480Y/277V 3P 4W
PANEL
P-H2 400A
MLO
480Y/277V 3P 4W
400225600
1000.A
1600S
1600S
400A 3P L
225A 3P L
600A 3P L
MDP-2
480Y/277V 3P 4W 1600A
ATS-2
XFMR UT-1
1,000 KVA
480Y/277V
GEN-1
480Y/277V 3P
500KW
400A 3P
225A 3P
225A 3P
100A 3P
125A 3P
200A 3P
PANEL
P-G2 225A
MLO
208Y/120V 3P 4W
PANEL
P-G1 225A
MLO
208Y/120V 3P 4W
PANEL
P-H
225A
MLO
208Y/120V 3P 4W
PANEL
P-J2 100A
MLO
208Y/120V 3P 4W
PANEL
P-J1 100A
MLO
208Y/120V 3P 4W
DP-1
208Y/120V 3P 4W 400A
XFMR DT-1
75 KVA
480V
TO 208Y/120V
PANEL
L-L
100A
MLO
480Y/277V 3P 4W
PANEL
P-A2 225A
MLO
480Y/277V 3P 4W
PANEL
P-A1 225A
MLO
480Y/277V 3P 4W
PANEL
P-C
100A
MLO
480Y/277V 3P 4W
PANEL
P-B
225A
MLO
480Y/277V 3P 4W
MDP
480Y/277V 3P 4W
1200AF
P-D 480Y/277V 3P 4W 400A
MLO
PANEL
DP-E
200A
MLO
480Y/277V 3P 4W
225 100
100125225
400J
225 100
400225225100
125D
70A 2P L
XFMR QT-1
45 KVA
480V 1Ø 120/240V 1Ø
PANEL
P-Q2 125A
MLO
240Y/120V 2P 3W
125/2D
1000A 3P
LS1
1600A 3P
LS1G
M
FEEDER SCHEDULE
ID FEEDER
AMPS
CONDUIT AND FEEDER
100 1-1/2"C,3#1,#1N,#8G
125 1-1/2"C,3#1/0,#1/0N,#6G
125 1-1/2"C,3#1/0,#6G
200 2"C,3#3/0,#3/0N,#6G
225 2-1/2"C,3#4/0,#4/0N,#4G
400 3-1/2"C,3#600kcmil,#600kcmil N,#2G
400 3-1/2"C,3#600kcmil,#600kcmil N,#1/0G
600 (2)3"C,3#350kcmil,#350kcmil N,#1G
1000 (3)3"C,3#400kcmil,#400kcmil N,#2/0G
SIZING METHOD: COPPER, 60°C #12 THROUGH #1, 75°C 1/0 AND ABOVE
1600S
1000.A
400J
125D
70 70 1-1/4"C,2#4,#4N,#8G
125 1-1/4"C,2#1/0,#6G125/2D
150 1-1/2"C,3#1/0,#6G150DJ
1600 (4)3-1/2"C,3#600kcmil,#600kcmil N,#4/0 G1600
(4)3-1/2"C,3#600kcmil,#600kcmil N
EXISTING TO REMAIN
NEW WORK
FAULT CURRENT SCHEDULE
DEVICE FAULT AIC RATING L-L VOLTS FEEDER
SIZE
FEEDER
LENGTH
RATING
P-H1
P-H2
QT-1
10,493
10,482
3,794
22,000
22,000
22,000
480V
480V
240V
#600KCMIL
#4/0
#4
292'
202'
233' 45 KVA
400 A
225 A
P-Q2 3,050 22,000 240V #1/0 12' 125 A
NO. DATE BY DESCRIPTION
REVISIONS
U
S
D
A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL COLD-WATER MARINE
AQUACULTURE CENTER
FRANKLIN, ME 04934
OF
A-E FIRM
PROJECT MANAGER EPM
DESIGNER PPM
CHECKED BY SAFETY & HEALTH
JOB # REAL PROPERTY
USDA
xxxxx xxxxx xxxxx xxxxx xxxxx
3724-M
E-601
POWER RISER
04/18/25
TT
EH
CGN.T.S.E-601
POWER RISER - PHASE 21
A. PANEL P-NM IS A PROPOSED PANEL FOR ANOTHER
PROJECT. SHOWN FOR LOAD CALCULATIONS.
GENERAL NOTES
NO. DATE BY DESCRIPTION
U S D A
PROJECT NO.
DATE
Agricultural Research Service
USDA AGRICULTURAL RESEARCH SERVICE
NCWMAC
RECIRCULATING AQUACULTURE UPGRADES
FRANKLIN, ME
SHEET
AGRICULTURE RESEARCH SERVICE
NATIONAL…
This is the start of the file's text. The full file is on GovTribe.