Attachment 4 - Drawing - Option 1.pdf

PDF 35 KB Posted

Attached to
Recirculating Aquaculture System Upgrades Federal contract opportunity
Solicitation number
1232SA26Q0302
Issued by
Department of Agriculture Agricultural Research Service

About this file

This document is a design specification for an electrical switchgear roof structure as part of the Recirculating Aquaculture Upgrades project at the National Cold-Water Marine Aquaculture Center (NCWMAC) in Franklin, Maine, dated February 18, 2026.

The roof structure is designed to house electrical switchgear equipment and features overall dimensions of 8'-10" wide by 6'-0" tall. The structure includes a metal deck roof, 3x3 tube framing, and accommodates a 24"x36" unit with space reserved for a future unit. The plan view shows the layout with specific spacing measurements (8", 3'-0", 1'-6", 3'-0", 8" horizontal divisions and 2'-0" vertical sections), while the front elevation illustrates the metal deck, switchgear positioning, and tube framing configuration. Key material and construction requirements include: roof material matching the main building roof in thickness, color, and profile; sloped roof design to properly shed rain, snow, and ice; and painting of all steel columns and roof framing to match the existing building. The structure is designed to integrate seamlessly with the existing facility's architectural and structural standards.

View the file

Other files for this federal contract opportunity

Other files attached to Recirculating Aquaculture System Upgrades, newest first.
File Type Posted
SF30 - Amendment 02.pdf PDF
RFI 2 - Clarification.pdf PDF
SF30 - Amendment 01.pdf PDF
Site Visit Sign In Sheet - Mar 17.pdf PDF
Site Visit Sign In Sheet - Mar 18.pdf PDF
RFIs.pdf PDF
Attachment 3 - Specifications - Base.pdf PDF
Attachment 5 - Drawings - Options 2 and 3.pdf PDF
Wage Determination.pdf PDF
Attachment 1 - Solicitation Terms and Conditions.pdf PDF
Attachment 2 - Drawings - Base.pdf PDF
Attachment 6 - Specifications - Options 2 and 3.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Recirculating Aquaculture Upgrades National Cold-Water Marine Aquaculture Center (NCWMAC) Franklin, ME Option for Electrical Switchgear Roof Structure February 18, 2026

Notes:

1. Roof material shall match main building roof thickness, color & profile.

2. Roof structure shall be sloped to shed rain/snow/ice.

3. Paint all steel columns and roof framing to match the existing building.

ChristopherG.Morris Rectangle

ChristopherG.Morris Rectangle

File details come from the government source that posted it. Updated .