ATTACHMENT 5 - Drawings 4 of 7.pdf
PDF 12 MB Posted
- Solicitation number
- 36C77621B0005
About this file
This notice provides details for a federal construction contract solicitation. The Department of Veterans Affairs intends to award a firm-fixed-price contract for an expansion and renovation project at the Oscar G. Johnson VA Medical Center in Iron Mountain, Michigan. The scope of work involves adding 10,000 square feet to the existing hospital and renovating approximately 1,100 square feet of existing space on the first floor for primary care. The project includes architectural, site, structural, fire protection, HVAC, plumbing, electrical and other construction work. The solicitation will be issued as an Invitation for Bid to Service-Disabled Veteran-Owned Small Businesses only, with a size standard of $39.5 million. The performance period is approximately 546 calendar days from the notice to proceed. The magnitude of construction is estimated between $5 million to $10 million. The solicitation is expected to be released in March 2021.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ROOM
PROCEDURE
ALCOVE
UTILITY
SOILED
1267A
TOILET
PATIENT
1267B
GARAGE
AMBULANCE
LOCKERS
BREAK RM/
RM
EXAM
WORK RM
NURSE
ROOM
EXAM
RM
EXAM
RM
EXAM
RM
DECON
MEDICATION
UTILITY
SOILED
TOILET
PATIENT
RM
TREATMENT
RM
TREATMENT
ROOM
TREATMENT
MEDICATION
/SECURITY RM.
FIRE ALARM
TOILET
PATIENT
LOBBY
ELEVATOR
TOILET
1224A
ROOM
COAT
OFFICE
PHARMACY
PHARMACY
MAIN
VAULT
MED PREP
SECURE
TOILET
PATIENT
CLERKS
RM
EXAM
WORKRM
NURSE
RM
EXAM
ROOM
EXAM
RM
EXAM
SUPPLY
STERILE
ROOM
EXAM
ROOM
ANTE
1312A
STATION
NURSE
DICTATION
WORKRM
NURSE
RM
EXAM
RM
EXAM
LINEN
CLEAN
HOUSEKEEPING
TOILET
STAFF
ISOLATION
TREATMENT/
TREATMENT
SECURE
TOILET
WOMENS
LAB/EKG
BLOOD DRAW
LAB/EKG
BLOOD DRAW
PT. TOILET
1312B
EQUIPMENT
PHARMACIST
CLINICAL
DISPENSING
OUTPATIENT
CLOSET
HSKPG
HSKPG
ELIGIBILITY
ENROLLMENT &
AREA
WAITING
AREA
CLERK
ELECTRICAL
CONSULTING
PHARMACY
DATA
DATA & PHONE
1218A
EQUIPMENT
ELEVATOR
VESTIBULE
AREA
WAITING
CONSULTING
1218B
CONSULTING
1218C
TRIAGE
STORAGE
WHLCHR
VESTIBULE
MRI
1304A
TOILET
STAFF
1340A
RM
CHANGING
1304C
RM
CHANGING
1304B
VESTIBULE
MRI
ROOM
EXAM
TOILET
PATIENT
ALCOVE
SCALE
TOILET
MENS
STAIR4
STAIR3
ALCOVE
PYXIS
FIRE
EQUIP
LO
CK
ER
S
BASEMENT ROOF
BASEMENT ROOF
LDRY
CHUT
RM
EXAM
DNUP
UP
DN
VOLUNTEER
AREA
MECH.
CHASE
CARPET
CARPET TILE
TILE
MECH
SHAFT
FD
FE FE
1 "/1 4
1 "/1 4
2 "/1 2 2 "/1 2
2 "/1 2
1"1" 1"
1"
1"
1"
1"
2"
2"
1 "/1 4
2"
2"
2"
2"
2"
2"
2"
1 "/1 4
1 "/1 4 1 "/1 4
1 "/1 4
1 "/1 4
1 "/1 4 1 "/1 4
1 "/1 4
1 "/14
1 "/1 4
1 "/1 4
1 "/1 4
1 "/1 4
1" 1"
1" 1"
1" 1"
1"
1"
1"
2" 2" 2"
2"
2"
2"
2"
2"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1"
1"
1" 1"
1"1"
1 "/1 4
/1
1 "
1"
1"
1" 1"
1"
1" 1"
1"
1"
1"
1"
1 "/1 4
1"
1"
1"
1 "/1 4 1 "/1 4
/1
1 "
1 "/1 4
/14 1 "
/1
1 "
1 "/1 4
/1
1 "
/1
1 "
/1
1 "
/1
1 "
1"
1"
1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1 "/1 4
1 "/1 4
1 "/1 4
1"
1 "/1 4
/12 2 "
4"
2 "/
3"
3"
/1
2 " 2 "/1 2
1"
1"
1"
4 4 4
47 47
47 47
2-1/2"
REMOVE
EXISTING
2-1/2" MAIN
REMOVE
EXISTING
3" MAIN
AND VALVE
4"
DRAIN
7 7 7
4 4
REMOVE AND REPLACE PIPING
AND SPRINKLER HEADS TO
ALLOW FOR HVAC AND
PLUMBING MODIFICATIONS IN
THIS AREA.
REMOVE/REPLACE CONTROL AND CHECK
VALVES FLOW/TAMPER SWITCHES, PRESS. GAUGE
AUX. DRAIN
2-1/2"DRAIN-DN
4"-DN
REDUCER(S)
4"-UP
2-1/2"DRAIN-UP
2 2
2 2 2 2
AUX
DRAIN
1 1
REMOVE 4" FP MAIN
REMOVE 2-1/2" MAIN-UP
REMOVE 2-1/2" MAIN-UP
CHECK
VALVES
FIRE PROTECTION PLAN KEYED NOTES
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
DRAWING
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
FUTURE POINT OF CONNECTION7
A
B
C
D
E
F
12347828262524232120
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:1
P
M
B.V.L. K.K.S.
FD101
FIRST FLOOR DEMOLITION PLAN
DWG. 81 OF 147
N
1/8" = 1'-0"FD101
FIRST FLOOR DEMOLITION PLANF1
0 6" 12" 18"3"
0 6" 12" 18"3"
N
1/8" = 1'-0"FD101
BUILDING 3 - BASEMENT DEMOLITION PLANF7
TOILET
PATIENT
ULTRASOUND
ROOM
TECH. WORK
SUPPLY
CLEAN
VIEWING
PACS
TOILET
PT.
ROOM
CHANGING
TOILET
STAFF
HSKG
CONTROL
CT SCAN
CT SCAN
TOILET
PT.
HOT LAB
2254A
MEDICINE
NUCLEAR
DENSITY
BONE
CHUTE
LAUNDRY
UTILITY
ROOM
CONTROL
2263A
RADIOLOGY
SCANNER
GE CT
STORAGE
2263B
CLEAN
STERILE
CYSTOSCOPY
CLOSET
HSKG
MECHANICAL
MECHANICAL
2307A
LOBBY
ELEVATOR
PHONE
DATA &
2218 ALCOVE
EQUIP.
2230A
CORRIDOR
2230P
ROOM
TECH WORK
C2-2
CORRIDOR
SOCIAL
WORKER
ACCUPUNCTURE
EXAM ROOM
DATA
CLOSET
ACCUPUNCTURE
EXAM ROOM
EYE PRE-
TREATMENT
EYE PRE-
TREATMENT
OFFICE
STAFF
LOUNGE
STERILE
SUPPLY
CLEAN
SUPPLY
SOCIAL
WORKER
2335A
PATIENT
TOILET
CHEMOTHERAPY
MENTAL HEALTH
EXAM
HSKG CLST
ELECTRICAL
ROOM
LANE
ROOM
LANE
ROOM
LANE
ROOM
EYE
INSTRUMENTS
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
TELE-HEALTH
OFFICE
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
MENS
TOILET
WAITING
AREA
ROOM ROOM
WOMENS
TOILET
CLERKS
AREA
2374A
STAFF
WORK AREA
CORRIDOR
STAFF
TOILET
SUB-WAIT
AREA
WOMENS
HEALTH EXAM 2352
TOILET
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
FAMILY
LOUNGE
2338A
FAMILY
RESTROOM
ONOCOLOGY
EXAM/OFFICE
ONOCOLOGY
EXAM/PROC.
SOILED
LINEN
2261A
CONTROL
ROOM
CLERK
CHECK-IN
WAITING
AREA
FEMALE
TOILET
MALE
TOILET
C2-1
CORRIDOR
AREA
DUMBWAITER
/CART ALCOVE
2110B
SCRUB
ALCOVE
2252P
CORRIDOR
CORRIDOR
PASSENGER
ELEVATOR
PASSENGER
ELEVATOR
STAIR 3
UP
DN
STAIR 4
UP
DN
MECH
CHASE
MECH.
SHAFT
CHASE
MECH.
SHAFT
CHASE
FIRST FLOOR ROOF
FIRST FLOOR ROOF
BASEMENT ROOF
BASEMENT ROOF
1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"1"
1"
1 "/1 4
1 "/1 4
1 "/1 4 1 "/1 4
/1
1 "
1 "/1 41 "/1 21 "/1 2
2"
2"
2"
2"2"
2"
2" 2"
2"
2"2"
2 "/1 2
/1
2 "
2 "/1 2
2 "/1 2
2 "/12
3"
3" 3"
2 "/
2-1/2"
2-1/2"
REDUCER
4"
3"
2"DR.
REMOVE AND REPLACE
EXISTING 2-1/2" MAIN
REMOVE/REPLACE CONTROL AND CHECK
VALVES FLOW/TAMPER SWITCHES, PRESS. GAUGE
AUX. DRAIN #65
AUX.
DR. #59
AUX.
DR. #60
1"
1" 1"
1"
1"
1"
1" 1"
1" 1"
1"1"
1"1"
1" 1"
1" 1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1 1/2" 1 1/2"
AUX. DR.
EXISTING VALVE,
FLOW, TAMPER - N/C
4"-UP/DN
2-1/2"DRAIN-UP/DN
2-1/2"-UP
FDC
FIRE PROTECTION PLAN KEYED NOTES
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
DRAWING
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
FUTURE POINT OF CONNECTION7
A
B
C
D
E
F
12347828262524232120
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:1
P
M
B.V.L. K.K.S.
FD102
SECOND FLOOR DEMOLITION PLAN
DWG. 82 OF 147
N
1/8" = 1'-0"FD102
SECOND FLOOR DEMOLITION PLANF1
0 6" 12" 18"3"
0 6" 12" 18"3"
N
1/8" = 1'-0"FD102
BUILDING 3 - FIRST FLOOR DEMOLITION PLANF7
COILING OH DOOR
TA
RA
M
P
COILING OH COILING OH
DOOR
LIFT
SLOPED CEILING
COILING OH FABRIC
DOOR
TA
PI
PE
CH
AS
E
COILING OH
DOOR
LIFT
COILING OH
DOOR
EXTERIOR
PLATFORM
EXTERIOR
HEATED
SLOPED
WALKWAY
FIRE
EQUIP
FIRE
EQUIP
UP
STAIR 3
MECH
SHAFT
FD
FD
LOBBY
ELEVATOR
B224
BREAKOUT
STOCK /
B287
DECONTAMINATION
B295
PACKAGING
PREPARATION
B291B
STERLIZER
B291C
RECEIVING
SHIPPING &
B274
SHREDDER RM.
RECYCLING &
B278
STORAGE
WAREHOUSE
B298
EQUIP.
NON-EXP
B298A
LOGISTICS
STORAGE
B231
ROOM
MECH.
B224C
EQUIPMENT
ELEVATOR
B224B
ROOM
MECHANICAL
B224A
LOCKERS
B297
CHUTE
LAUNDRY
B230
ACCESS
MECH.
B227
ACCESS
MECH.
B295A
ROOM
MECH.
B231B
DATA
B296
C O
R R
ID
O
R
B
9C -1
VESTIBULE
B276
C O
R R
ID
O
R
B
9D -1
CORRIDOR
B299B-1
LOUNGE
B226
LOCKER
B226A
SHOWER
B226C
TOILET
B226B
COOLER
MORGUE
B273
O2 STOR
B268
EQUIP. RM.
ELECTRICAL
B278A
LOGISTICS
OFFICE
B298B
DOCK
LOADING
B272
3" 3"
4"
3"
HOSE
VALVE
HEAD BELOW
STAIR LANDING
SIDEWALL
SP. HEAD(S)
4"-UP
3"FP-UP
D8
F101
FLOOR
COTNROL
3"FP-UP
PROVIDE UNISTRUT SUPPORTS
(FROM SHAFT WALLS) FOR NEW
PIPING IN SHAFT. COORDINATE
LOCATION WITH EXISTING CONDUIT
RACKED IN SHAFT (ALL FLOORS).
1"
DRAIN & TEST MASTER #16/#17
1"
1"
1"
1/ 2"
1"
1/ 2"
AUX. DR. 1
1/ 2"
1/ 2"
VLV. #15
SP
VLV. #19
AUX. DR.
2"
4"
2"
2"
MAIN VALVE #1
CONT.
4"
VLV. #14
4"
6"
4"
4"
1" 1"
4" 4"
1" 1"
1"
(N O N
U M B
ER
DR
AI
N V
AL
VE
VA
LV
E
DR
AI
N
2"
2"
1" 1"
6"
DI
SS
C O N N
EC
TE
D
FL
O W S W
IT
C H
VL
V.
2"
VLV. #13
AUX.M
AI
N
6"
2" 2"
1"
1"
1"
1"
1"
1 1/4"
1/
2" 1/
2"
1" 2" 2"
2"
2" 2"
1"
1 1/2"1 1/2"
1"
1" 1"
1/
4"
1" 1" 1"
1" 1" 1"
1" 1"
1 1/4"
1 1/2"
1" 1"1" 1"
1"
1"
1" 1"
1"
1" 1"
1" 1"
1" 1"
1" 1"
1"1"
1"
1"
1"
1"1" 1"
1"
1"
1"
4"RISER
1"1"
1"
-1
0½4
48-5\
-44
-4
2"
36-3
2"
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
A
12347828262524232120 1.3 0.7
B.4
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
A1
F101 SHEET DETAIL OR DIAGRAM IS DRAWN ON
DETAIL OR DIAGRAM NUMBER
FIRE PROTECTION PLAN KEYED NOTES
DESCRIPTIONSYMBOL
FIRE PROTECTION SYMBOLS
CONCEALED PENDENT SPRINKLER
SPRINKLER SYSTEM RISER
SPRINKLER SYSTEM DROP
EXISTING SPRINKLER SYSTEM PIPING TO BE REMOVED
FIRE RATED PIPE SLEEVE
F.R.P.S.
FLOW SWITCH
ELEVATION-CENTERLINE OF PIPE TO FINISHED FLOOR"X"
ROOM NUMBER
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
ROOM NAME
EXISTING PENDENT SPRINKLER-NO CHANGE
EXISTING PENDENT SPRINKLER TO BE REMOVED
STANDARD SPRAY UPRIGHT SPRINKLER
EXISTING UPRIGHT SPRINKLER-NO CHANGE
NEW BUTTERFLY VALVE (B-FLY) WITH TAMPER SWITCH
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
CORR.
CEILING REMOVAL & REPLACEMENT
- (FIRE PROTECTION)
DRAWING
EXISTING UPRIGHT SPRINKLER TO BE REMOVED
WET SPRINKLER MAIN PIPING
LOW POINT AUXILIARY DRAIN
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
PRESSURE GAUGE
SIGHT GLASS
TEST/DRAIN VALVE
x xx EXISTING SPRINKLER SYSTEM PIPING
DRAIN PIPE
DRY VALVE SYSTEM
GLYCOL SYSTEM
PREACTION SYSTEM
N
F
E
FUTURE
EXISTING
NEW
CHECK VALVE
BUTTERFLY VALVE
BALL VALVE
CORE DRILL
KEYED PLAN NOTE
x PIPING TO BE ABANDONED (PER PLBG. CODE) - SEE PLAN FOR NOTES. x
FUTURE POINT OF CONNECTION7
IN AREAS AFFECTED UNDER THE SCOPE OF THE PROJECT WORK, THE GENERAL
TRADE SHALL REMOVE AND REINSTALL EXISTING CEILING TILE SYSTEM TO ALLOW
FOR THE REMOVAL AND INSTALLATION OF THE FIRE PROTECTION SYSTEM - SEE
PROJECT MANUAL (GENERAL TRADE TO VERIFY CEILING TILE SYSTEM). THE
GENERAL TRADE SHALL TEMPORARILY ADJUST/SUPPORT EXISTING LIGHT
FIXTURE(S), SMOKE DETECTOR(S), PAGING SPEAKER(S), AND NURSE CALL DEVICE(S)
AS REQUIRED TO ACCOMODATE THE FIRE PROTECTION INSTALLATION. REINSTALL
FIXTURE(S) AND DEVICE(S) TO THEIR ORIGINAL LOCATIONS UPON FIRE PROTECTION
INSTALLATION COMPLETION. IN ROOM CONTAINING PLASTER CEILING, OPENINGS
SHALL BE CUT BY THE GENERAL TRADE. NEW ACCESS PANEL(S) (24"x 24") SHALL BE
SUPPLIED BY THE FIRE PROTECTION TRADE FOR INSTALLATION BY THE GENERAL
TRADE AS REQUIRED. FIRE PROTECTION TRADE TO COORDINATE QUANTITY AND
LOCATION OF ACCESS PANEL(S) WITH GENERAL TRADE.
SIDEWALL PENDENT SPRINKLER
EXISTING SIDEWALL PENDENT SPRINKLER
EXISTING SIDEWALL PENDENT SPRINKLER TO BE REMOVED
FLOW SWITCH
BUTTERFLY VALVE
W/ TAMPER SWITCH
PSI GAUGE W/
GATE VALVE
CHECK VALVE
TEST DRAIN
VALVE
PAINT RED TO MATCH
EXISTING PIPING -
VERIFY COLOR
FINISHED CEILING
THREADED TEE
SPRINKLER BRANCH
CONCEALED SPRINKLER
FINISHED CEILING
1" THREADED ELBOW
REDUCER COUPLING
1" SCH. 40 PIPE
PIPE 2" AND SMALLER
CONCEALED SPRINKLER
1" SCH. 40 PIPE
1" THREADED ELBOW
THREADED OUTLET
TEE COUPLING
FINISHED CEILING
CONCEALED SPRINKLER
SPRINKLER MAIN PIPE
WELDED OUTLET
NOTE: ALL SPRINKLER PIPING TO
BE SUPPORTED PER NFPA-13 AND
FOR WORKING PRESSURES
EXCEEDING 100 PSI.
2 " AND LARGER1/2
NOTE: ARM-OVERS SHALL BE INSTALLED
ON ALL WET PIPE STYLE SPRINKLER
HEADS REGARDLESS OF WATER SOURCE.
NOTE: FOR MECHANICAL TEES, ONLY THE
VICTAULIC STYLE 920/920N MECHANICAL-T
GROOVED OR THREADED OUTLET CONNECTION
WILL BE ACCEPTED. (MECHANICAL TEES WITH U-
BOLT ONLY AROUND PIPE ARE NOT ACCEPTABLE.
SPRINKLER MAIN PIPE
2 " AND LARGER1/2
1" SCH. 40 PIPE
1" THREADED ELBOW
NOTE: ALL ARMOVERS SHALL BE STEEL PIPE
WITH LENGTHS TO BE FIELD VERIFIED AND CUT
TO CORRECT LENGTH ON SITE. WHERE
SPRINKLER DROPS ARE PREFABRICATED IT IS
THE FIRE PROTECTION CONTRACTOR'S
RESPONSIBILITY TO FIELD CUT PIPE LENGTHS TO
FIT THE CEILING AS CONSTRUCTED. FLEXIBLE
SPRINKLER DROPS ARE NOT ACCEPTABLE.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:0
P
M
B.V.L. K.K.S.
F101
BASEMENT NEW WORK PLAN
DWG. 83 OF 147
N
1/8" = 1'-0"F101
BASEMENT NEW WORK PLANF1
0 6" 12" 18"3"
NO SCALEF101
B7 FLOOR CONTROL ASSEMBLY
NO SCALEF101
D6 ARMOVER DETAIL
ALCOVE
UTILITY
SOILED
1267A
TOILET
PATIENT
1267B
GARAGE
AMBULANCE
LOCKERS
BREAK RM/
RM
EXAM
WORK RM
NURSE
ROOM
EXAM
RM
EXAM
RM
EXAM
RM
DECON
MEDICATION
UTILITY
SOILED
TOILET
PATIENT
RM
TREATMENT
RM
TREATMENT
ROOM
TREATMENT
MEDICATION
/SECURITY RM.
FIRE ALARM
TOILET
PATIENT
LOBBY
ELEVATOR
TOILET
1224A
ROOM
COAT
OFFICE
PHARMACY
PHARMACY
MAIN
VAULT
MED PREP
SECURE
TOILET
PATIENT
CLERKS
RM
EXAM
WORKRM
NURSE
RM
EXAM
ROOM
EXAM
RM
EXAM
SUPPLY
STERILE
ROOM
EXAM
ROOM
ANTE
1312A
STATION
NURSE
DICTATION
WORKRM
NURSE
RM
EXAM
RM
EXAM
LINEN
CLEAN
HOUSEKEEPING
TOILET
STAFF
ISOLATION
TREATMENT/
TREATMENT
SECURE
TOILET
WOMENS
LAB/EKG
BLOOD DRAW
LAB/EKG
BLOOD DRAW
PT. TOILET
1312B
EQUIPMENT
PHARMACIST
CLINICAL
DISPENSING
OUTPATIENT
CLOSET
HSKPG
HSKPG
ELIGIBILITY
ENROLLMENT &
AREA
WAITING
AREA
CLERK
ELECTRICAL
CONSULTING
PHARMACY
DATA
DATA & PHONE
1218A
EQUIPMENT
ELEVATOR
VESTIBULE
AREA
WAITING
CONSULTING
1218B
CONSULTING
1218C
TRIAGE
STORAGE
WHLCHR
VESTIBULE
MRI
1304A
TOILET
STAFF
1340A
RM
CHANGING
1304C
RM
CHANGING
1304B
VESTIBULE
MRI
ROOM
EXAM
TOILET
PATIENT
ALCOVE
SCALE
TOILET
MENS
STAIR4
STAIR3
ALCOVE
PYXIS
FIRE
EQUIP
LO
CK
ER
S
BASEMENT ROOF
BASEMENT ROOF
LDRY
CHUT
RM
EXAM
DNUP
UP
DN
VOLUNTEER
AREA
MECH.
CHASE
CARPET
CARPET TILE
TILE
MECH
SHAFT
FD
FE FE
1 "/1 4
1 "/1 4
2 "/1 22 "/1 2
2 "/1 2
1"1" 1"
1"
1"
1"
1"
2"
2"
1 "/1 4
2"
2"
2"
2"
2"
2"
2"
1 "/1 4
1 "/1 4 1 "/1 4
1 "/1 4
1 "/1 4
1 "/1 4 1 "/1 4
1 "/1 4
1 "/14
1 "/1 4
1 "/1 4
1 "/1 4
1 "/1 4
1" 1"
1" 1"
1" 1"
1"
1"
1"
2" 2" 2"
2"
2"
2"
2"
2"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1"
1"
1" 1"
1"1"
1 "/1 4
/1
1 "
1"
1"
1" 1"
1"
1" 1"
1"
1"
1"
1"
1 "/1 4
1"
1"
1"
1 "/1 4 1 "/1 4
/1
1 "
1 "/1 4
/1
1 "
/1
1 "
1 "/1 4
/1
1 "
/1
1 "
/1
1 "
/1
1 "
1"
1"
1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1 "/1 4
1 "/1 4
1 "/1 4
1"
1 "/1 4
4"
2 "/
3"
/1
2 "
4"
3"3"
3"
3"
3"
3"
3" 3"
3"
4"
4"
4"-UP
4"-DN
3"FP-DN
3"FP-DN
2-1/2"
4"
DRAIN
NOTE: NEW PIPING IN
STAIRWELL TO BE PAINTED
RED TO MATCH EXISTING.
NEW VALVES,
FLOW, TAMPER
HOSE
VALVE
NOTE: EXPOSED PIPING IN
STAIRWELL TO BE PAINTED
RED TO MATCH EXISTING.
PROVIDE UNISTRUT
SUPPORT IN MECH.
SHAFT.
2 2 2
INSTALL TIGHT
TO BOTTOM OF
SPANDREL BEAM,
LINTEL AND
BRICK LEDGE
D8
F101
FLOOR
CONTROL
SIDEWALL
SP. HEADS
COORDINATE INSTALLATION WITH
HVAC AND PLUMBING
MODIFICATIONS. RACK FP PIPING IF
REQUIRED. - COORDINATE
INSTALLATION.
AUX. DRAIN
2-1/2"DRAIN-DN
4"-DN
REDUCER(S)
4"-UP
2-1/2"DRAIN-UP
2 2 2 2
AUX
DRAIN
1 1
FIRE PROTECTION PLAN KEYED NOTES
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
DRAWING
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
FUTURE POINT OF CONNECTION7
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:0
P
M
B.V.L. K.K.S.
F102
FIRST FLOOR NEW WORK PLAN
DWG. 84 OF 147
N
1/8" = 1'-0"F102
FIRST FLOOR NEW WORK PLANF1
0 6" 12" 18"3"
ULTRASOUND
ROOM
TECH. WORK
SUPPLY
CLEAN
VIEWING
PACS
TOILET
PT.
ROOM
CHANGING
TOILET
STAFF
HSKG
CONTROL
CT SCAN
CT SCAN
TOILET
PT.
HOT LAB
2254A
MEDICINE
NUCLEAR
DENSITY
BONE
CHUTE
LAUNDRY
UTILITY
ROOM
CONTROL
2263A
RADIOLOGY
SCANNER
GE CT
STORAGE
2263B
CLEAN
STERILE
CYSTOSCOPY
CLOSET
HSKG
MECHANICAL
MECHANICAL
2307A
LOBBY
ELEVATOR
PHONE
DATA &
2218 ALCOVE
EQUIP.
2230A
CORRIDOR
2230P
ROOM
TECH WORK
C2-2
CORRIDOR
SOCIAL
WORKER
ACCUPUNCTURE
EXAM ROOM
DATA
CLOSET
ACCUPUNCTURE
EXAM ROOM
EYE PRE-
TREATMENT
EYE PRE-
TREATMENT
OFFICE
STAFF
LOUNGE
STERILE
SUPPLY
CLEAN
SUPPLY
SOCIAL
WORKER
2335A
PATIENT
TOILET
CHEMOTHERAPY
MENTAL HEALTH
EXAM
HSKG CLST
ELECTRICAL
ROOM
LANE
ROOM
LANE
ROOM
LANE
ROOM
EYE
INSTRUMENTS
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
TELE-HEALTH
OFFICE
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
MENS
TOILET
WAITING
AREA
ROOM ROOM
WOMENS
TOILET
CLERKS
AREA
2374A
STAFF
WORK AREA
CORRIDOR
STAFF
TOILET
SUB-WAIT
AREA
WOMENS
HEALTH EXAM 2352
TOILET
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
FAMILY
LOUNGE
2338A
FAMILY
RESTROOM
ONOCOLOGY
EXAM/OFFICE
ONOCOLOGY
EXAM/PROC.
SOILED
LINEN
2261A
CONTROL
ROOM
CLERK
CHECK-IN
WAITING
AREA
FEMALE
TOILET
MALE
TOILET
C2-1
CORRIDOR
AREA
DUMBWAITER
/CART ALCOVE
2110B
SCRUB
ALCOVE
2252P
CORRIDOR
CORRIDOR
PASSENGER
ELEVATOR
PASSENGER
ELEVATOR
STAIR 3
UP
DN
STAIR 4
UP
DN
MECH
CHASE
MECH.
SHAFT
CHASE
MECH.
SHAFT
CHASE
FIRST FLOOR ROOF
FIRST FLOOR ROOF
BASEMENT ROOF
BASEMENT ROOF
1"
1"
1"
1"
1"
1"
1"
1" 1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"1"
1"
1 "/1 4
1 "/1 4
1 "/1 4 1 "/1 4
/1
1 "
1 "/1 41 "/1 21 "/1 2
2"
2"
2"
2"2"
2"
2" 2"
2"
2"2"
2 "/1 2
2 "/1 2
3"
2 "/
4"
4"
4"
4"
4"
4"
4"
2-1/2"
2-1/2"
3"
2"DR.
4"-DN
NEW VALVES,
FLOW, TAMPER
HOSE
VALVE
NOTE: NEW PIPING IN
STAIRWELL TO BE PAINTED
RED TO MATCH EXISTING.
D8
F101
FLOOR
CONTROL
AUX. DRAIN #65
AUX.
DR. #59
AUX.
DR. #60
1"
1" 1"
1"
1"
1"
1" 1"
1" 1"
1"1"
1"1"
1" 1"
1" 1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1"
1 1/2" 1 1/2"
AUX. DR.
EXISTING VALVE,
FLOW, TAMPER - N/C
4"-UP/DN
2-1/2"DRAIN-UP/DN
2-1/2"-UP
FIRE PROTECTION PLAN KEYED NOTES
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
DRAWING
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
FUTURE POINT OF CONNECTION7
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:1
P
M
B.V.L. K.K.S.
F103
SECOND FLOOR NEW WORK PLAN
DWG. 85 OF 147
N
1/8" = 1'-0"F103
SECOND FLOOR NEW WORK PLANF1
0 6" 12" 18"3"
FIRST FLOOR ROOF
FIRST FLOOR ROOF
FIRST FLOOR ROOF
BASEMENT ROOF
BASEMENT ROOF
/2 "1
1"
B.D.
B.D.
B.D.
B.D.
2-1/2"
NEW AUX. DRAIN
2-1/2"-DN
1"
1"
1"
1" 1"
1"1"
1" 1"
1" 1"
1" 1"
1" 1"
1"
1"
1"
1"
1"
1"
6- 6\1
9-6
1\ 7-8\
1\
1- 7\2
7-
8-
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
O
N
M
L
K
J
H
G
F'
22 27 29
29.5
T
S
R
P
FIRE PROTECTION PLAN KEYED NOTES
1 EXISTING FIRE SPRINKLER PIPING/HEAD TO REMAIN-NO CHANGE
MAKE NEW CONNECTION TO EXISTING PIPING
REMOVE SPRINKLER AND PIPING CAP/EXTEND PIPE AS INDICATED ON
DRAWING
REMOVE EXISTING SPRINKLER AND ARMOVER TO BRANCHLINE FITTING.
MAKE NEW CONNECTION TO EXISTING FITTING AND EXTEND NEW ARMOVER
TO NEW SPRINKLER LOCATION AS INDICATED ON DRAWING
EXISTING FIRE MAIN/RISER TO REMAIN-NO CHANGE
EXISTING FIRE MAIN/RISER TO BE REMOVED, RELOCATED, OR REVISED TO
SUIT NEW REMODELING WORK
FUTURE POINT OF CONNECTION7
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d
P ri m a ry
C a re /V
A F
IR
E
.r v t
/4 /2
:2
:1
P
M
B.V.L. K.K.S.
F104
PENTHOUSE NEW WORK PLAN
DWG. 86 OF 147
N
1/8" = 1'-0"F104
PENTHOUSE NEW WORK PLAN1
4'0 8' 12'2'
ALCOVE
UTILITY
SOILED
1267A
TOILET
PATIENT
1267B
GARAGE
AMBULANCE
LOCKERS
BREAK RM/
RM
EXAM
WORK RM
NURSE
ROOM
EXAM
RM
EXAM
RM
EXAM
RM
DECON
MEDICATION
UTILITY
SOILED
TOILET
PATIENT
RM
TREATMENT
RM
TREATMENT
ROOM
TREATMENT
MEDICATION
/SECURITY RM.
FIRE ALARM
TOILET
PATIENT
LOBBY
ELEVATOR
TOILET
1224A
ROOM
COAT
OFFICE
PHARMACY
PHARMACY
MAIN
VAULT
MED PREP
SECURE
TOILET
PATIENT
CLERKS
RM
EXAM
WORKRM
NURSE
RM
EXAM
ROOM
EXAM
RM
EXAM
SUPPLY
STERILE
ROOM
EXAM
ROOM
ANTE
1312A
STATION
NURSE
DICTATION
WORKRM
NURSE
RM
EXAM
RM
EXAM
LINEN
CLEAN
HOUSEKEEPING
TOILET
STAFF
ISOLATION
TREATMENT/
TREATMENT
SECURE
TOILET
WOMENS
LAB/EKG
BLOOD DRAW
LAB/EKG
BLOOD DRAW
PT. TOILET
1312B
EQUIPMENT
PHARMACIST
CLINICAL
DISPENSING
OUTPATIENT
CLOSET
HSKPG
HSKPG
ELIGIBILITY
ENROLLMENT &
AREA
WAITING
AREA
CLERK
ELECTRICAL
CONSULTING
PHARMACY
DATA
DATA & PHONE
1218A
EQUIPMENT
ELEVATOR
VESTIBULE
AREA
WAITING
CONSULTING
1218B
CONSULTING
1218C
TRIAGE
STORAGE
WHLCHR
VESTIBULE
MRI
1304A
TOILET
STAFF
1340A
RM
CHANGING
1304C
RM
CHANGING
1304B
VESTIBULE
MRI
ROOM
EXAM
TOILET
PATIENT
ALCOVE
SCALE
TOILET
MENS
STAIR4
STAIR3
ALCOVE
PYXIS
FIRE
EQUIP
LO
CK
ER
S
BASEMENT ROOF
BASEMENT ROOF
LDRY
CHUT
RM
EXAM
DNUP
UP
DN
VOLUNTEER
AREA
MECH.
CHASE
CARPET
CARPET TILE
TILE
MECH
SHAFT
FD
FE FE
2"VT
3/4" HW & CW 1/2" HW
1/2" CW
1" HW
1" CW
CW
HW
VT
CW
HW
VT
1"HW
H/CW
VT
SINK
NOTE: REMOVE EXISTING HORIZONTAL
H/CW AND VENT PIPING SERVING
SINK(S) IN THIS AREA TO ALLOW FOR
DUCT DEMOLITION AND NEW
DUCTWORK, PLUMBING AND FIRE
PROTECTION PIPING - COORDINATE.
1/2"H/CW
1-1/2"VT9
1/2"H/CW
1-1/2"VT9
1/2"H/CW
1-1/2"VT9
1/2"H/CW
1-1/2"VT9
1/2"H/CW
1-1/2"VT
1/2"H/CW
1-1/2"VT
1/2"H/CW
1-1/2"VT
6"
1/2"CW
1/2"HW
1/2"H/CW
VT
2" V
V.P
V.P. (UP)
4" D.S.
V.P. (UP)
4" D.S.
2" VENT
2" VENT
1 1/2" VENT
V.P. (UP)
2" V UP
FINISH FLOOR ELEVATION = 1148.00'
2" V
2" V UP
CATCH BASIN
600 GALLON
HOLDING TANK
2" V-UP
1 1/4" V
1 1/2" V
2" V UP
C.O.
4" SS
4" SS
4" D.S.
2" SAN
4" SAN
4" SAN
1 1/2" SAN
2" SAN
4" SS
4" SAN
3" SAN
4" SS
2" SAN
3" FD
3" FD
4" W UP
4" SN DN CO
3" W& V UP
1-1/2" W DN
CO
4" W UP
1-1/2" W
1-1/2" W
4" W UP
2" W UP
1-1/2" W
2" W UP
1-1/2" W
4" W UP
4" W UP
1-1/2" W
1-1/2" W
4" W UP
2" W UP
1-1/2" W
1-1/2" W
1-1/2" W
1-1/2" W
2" W UP
1-1/2" W
1-1/2" W
4" W UP
1-1/2" W 1-1/2" W
1-1/2" W
1-1/2" W
1-1/2" W
2" W UP
1-1/2" W
1-1/2" W
1-1/2" W
4" W UP
CO
1-1/2" W
4" W UP
2" W UP1-1/2" W
4" SN UP
2"
3" 2"
4"
4"
4"
2" 4"
2"
2"
3"
4"
3" HUB OUTLET
4"
1-1/2" W
4"
CO
4" SN DN
2"
CO
4"
4" SN DN
4"
2" SAN
3" SAN
3" SAN
2" SAN
3" SAN
3" SAN
2" SAN
2" SAN
2" SAN
3" SAN
3"
SAN
3" SAN
2" SAN
2" SAN
2" SAN
2" SAN
2" SAN
1 1/2" SAN
3" W UP TO SS
4" W
UP TO
FD
4" SS/VP
4" SAN
2" SAN
3" SAN
2" SAN
2" SAN
3" SAN 3" SAN
4" SS UP
4" SAN
3" SAN
4" SS DN
2" SAN
4" SS
4" SS
3"
2"
3"
3"
2"
2"
4" ST DN
4" ST RISER
4" ST UP
EXIST. 5" ST UP/DN
4" ST UP
VERNACARE
4" SAN STACK
2" SAN
3" SS
3" SS DN
1 1/4" CW DN
1 1/4" CW DN
3/4"HWR DN
3/4" CW
3/4" HW
1/2" HWR
1" CW
3/4" HW
1/2" HWR
3/4" CW
3/4" HW
1/2" HWR
1" CW
3/4" HW
1/2" HWR
2" 1/2 CW, 1 1/2"
HW & 1/2" HWR
RISERS
1 1/2" CW
1/2" HW
1/2" HW & CW
1" CW
1/2" HW & CW
3/4" HW
1 1/2" CW
2" CW, 1 1/4" HW AND
3/4" HWR ABANDONED
2" C.W. 1 1/2" H.W.
1/2" H.W.R. 3/4" D.W.
3/4" CW UP
3/4" HW UP
1/2" HWR UP
1/2" CW DN
1/2" HW DN
1/2" C.W.
1/2" H.W.
1" C.W.
1" H.W.
1/2" H.W.R.
2" CW
TRAP PRIMER
3/4" DN TO GLASS FILLER
3/4" RAW WATER
3/4" RAW WATER UP & DN
3/4" RAW WATER1 1/2" RAW WATER
3/4" RAW WATER
1/2" HW & CW
1 1/2" CW
3/4" HW
1/2" CW & HW
2" CW
3/4" HW & CW
3/4" CW
1/2" CW & HW
3/4" HW
2" CW
2" CW
1" CW
1" HW
1" HW
1" CW 2" CW
1" HW
1 1/2" CW
1 1/2" CW
1/2" H&CW
1 1/4" HW
3/4" CW
1 1/4" HW
1" CW
1/2" HW
3/4" HW
1 1/2" CW
2" CW
1 1/4" HW
CAP
EMERGENCY EYEWASH
TRAP PRIMER
3/4" HW & CW
1/2" RPZ
3/4" HW & CW
1/2" HW & CW
3/4" HW & CW
1/2" HW & CW
3/4" DN TO EWC
SPRAY
NOZZLE ON
SINK
1 1/2" CW
3/4" HWR
1 1/2" CW
2" CW
1" HW
2" CW
3/4" HW
1" HW
3/4" RW
1/2" CW
1/2" HW
1/2" HW & CW
1/2" HW &
CW
1/2" HW &
CW
1 1/2" CW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2" CW
1/2" HW
1/2"H/CW
1 1/2" CW
EXISTING WALL MOUNTED DRENCH HOSE UNIT AND TEMPERING
VALVE RELOCATED FROM EXISTING DECONTAMINATION ROOM
2-1/2"CW-UP
1-1/2"HW-UP
3/4"HWR-UP
4"CW-DN
1-1/2"HW-DN
1"HWR-DN
ROOM
MECHANICAL
FIRST FLOOR ROOF
3/4"9
REMOVE AND RELOCATE
3/4" RPZ BACKFLOW
PREVENTER TO
PENTHOUSE RM #3331
4" RD4" RD
2"
FD
4"RC-DN
4"RC-UP
TO RD
1/2"CW-DN
3/4"CW-DN
SINK
SINK
SINK
A
B
C
D
E
F
123478
28262524232120
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
A
B
12347
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:2
P
M
B.V.L. K.K.S.
PD101
FIRST FLOOR DEMOLITION PLAN
DWG. 87 OF 147
N
1/8" = 1'-0"PD101
FIRST FLOOR DEMOLITION PLANF1
4'0 8' 12'2'
N
1/8" = 1'-0"PD101
PENTHOUSE DEMOLITION PLANF3
4" D.S. (UP)
REMOVE 4"
C.I.
SANITARY
5"
4"
C.O.
3/4" WALL HYDRANT
REMOVE 5"
C.I. STORM
REMOVE 11/2" C.W. SERVICE
3/4" H. & C.W. TO
SHOWERS ABOVE
1/2" C.W. TO W.C. ABOVE
5"
3/4"
1"
4" D.S. (UP)
1" C.W. TO URINAL ABOVE
11/4"
11/2"
1"
4" S.P. (UP)
1/2" H. & C.W. TO
LAVS. ABOVE
3/4"
1"
1/2"
3/4"
3/4"
4"
1"
3" 3"
3" F.D. WITH
INTEGRAL
B.W. VALVE
1"11/4"
3/4"
3/4" H. & C.W. TO
STAIR ABOVE
3" W.P. (UP)
3/4" WALL HYDRANT
OFFSET AT CLG
3/4"
REMOVE 5"
C.I. STORM
CW
WH
SOCIAL ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
BED
ROOM
LINEN
TOILET
AND
BATH
CORRIDOR
LOBBY
PHONE
JAN
STAIR
P-14
3" W.P.-V.P. 4" THRU ROOF
4" D.S.-UP/DN
4" S.P.-V.P.-5" THRU ROOF
4" D.S.-UP/DN
4"
4"
2"
DROP BELOW BASEMENT FLOOR
11/2" W.P.-V.P.
2"
2" W.P.-V.P.
3" THRU ROOF2" W.P.-V.P.-3" THRU ROOF
2"
(2)SH,(3)L
(2)CW,UR
(2)FD
4" V.P.
4" R.D.
3" V.P.
3" V.P.
3" V.P.
4" R.D.5
DY
H s s s
DY
H s s
D
D D
D
DD
D
DD
D
IR
REMOVE EXISTING
4" SANITARY
REMOVE
EXISTING
6" STORM
REMOVE
EXISTING
6" STORM
CAP 1-1/2"
IN TUNNEL
CAP
CAP
CAP
REMOVE EXISTING 1-1/2"
COLD WATER BACK
THROUGH TUNNEL
PIV
IRRIGATION
BOX
PIV
BOX
IRRIGATION
St m
St m
S tm
8" Stm3 S tm
S tm
" S tm
S tm
St m
8" Stm 15"
Stm
S tm
S tm
S tm
S tm
24" Stm
15" Stm
8" Stm
15" Stm
15" Stm
S tm
San MH Rim 1143.33
IE 1132.41
S tm
10" Stm
S t m
8" Stm
S t m
S a n
S a n
8" San
MH SAN
RIM 1146.56
IE 1128.92
S a n
8" San
8" San
S a n
S a n
Ab an do ne d
S tm
F o rc e m a in
A p p ro x Lo c a ti o n
S tu b
10" Stm
MH SAN
RIM 1147.48
MH SAN
RIM 1142.44
MH SAN
RIM 1141.33
MH SAN
RIM 1147.70
10" Stm
CB
RIM 1145.31
DRY SUMP
CB
RIM 1146.3
CB
RIM 1142.84
CB
RIM 1142.90
CB
RIM 1136.44
MH STM
RIM 1141.51
CB
RIM 1142.42
CB
RIM 1131.68
CB
RIM 1131.47
CB
RIM 1131.58
CB
RIM 1131.59
RIM 1133.08
MH STM
RIM 1133.56
MH STM
RIM 1131.71
CB
RIM 1142.12
CB
RIM 1142.38
MH STM
RIM 1141.58
CB
RIM 1133.55
CB
RIM 1133.32
CB
RIM 1133.55
CB
RIM 1136.49
TRENCH DRAIN
CB
RIM 1140.90
CB
RIM 1141.51
CB
RIM 1142.39
CB
RIM 1146.88
CB
RIM 1143.49
MH STM
RIM 1143.19
TRENCH
DRAIN
Stm MH/Inlet Rim 1134.03
IE 1125.2
Stm MH/Inlet Rim 1137.03
IE 1126.9
CB
RIM 1142.66
2" VENT LINE
1-GASALINE PUMP
2" PUMP SUCTION
1000GAL STORAGE
TANKS
PIV
TUNNEL
SMOKER
BLDG
BLDG
MAIN BUILDING
FUEL
STATION
FUEL
STATION
BLDG
F U E L
S T A T
IO
N
HAZ.
STORAGE
MAIN BUILDING
BLDG
BLDG
#20
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:2
P
M
B.V.L. K.K.S.
PD102
BUILDING 3 DEMOLITION PLANS
DWG. 88 OF 147
N
1/8" = 1'-0"PD102
BUILDING 3 - BASEMENT DEMOLITION PLANF7
N
1/8" = 1'-0"PD102
BUILDING 3 - FIRST FLOOR DEMOLITION PLANE7
N
1/8" = 1'-0"PD102
BUILDING 3 - SECOND FLOOR DEMOLITION PLANC7
4'0 8' 12'2'
4'0 8' 12'2'
4'0 8' 12'2'
N
1" = 30'-0"PD102
SITE PLANF2
AHU
ST
EA
M
TU
NN
EL
STAIR 2
UP
FD
Fire Pump System
ERV−4
M a te ri a l S to ra g e
Steam Piping
LIFT
STATION
F1
PK501
DRAINTILE
SUMP/PUMP
6"RC-UP
3"VT-UP
4" IE=1135'-8" 4"
4"W.-UP TO
4"FD#B001
4"W.-UP
TO F.CO
6"
6" STORM @
IE=1135.17' SEE
SHEET C500 FOR
CONTIUATION
SLEEVE WALL
@ IE=1135.25'
SLEEVE WALL
@ IE=1135'-8"
SLEEVE WALL
@ IE=1135'-11"
SLEEVE WALL
SLEEVE WALL
IE=1136'-3"
SLEEVE WALL
@ IE=1135'-10"
C2
PK501
DT.CO.
C2
PK501
DT.CO.
IE=1135'-7"
IE=1136'-1"
SLEEVE DRAINTILE
HIGHPOINT IE=1140'-2"
PITCH
P
IT
C H
PITCH
P
IT
C H
SLEEVE WALL
IE=1134.92'
BWV-1
4" SANITARY @
IE=1134.75' SEE
SHEET C500 FOR
CONTINUATION
4"W.-UP
PITCH
PITCH
P
IT
C H
2"VT-UP
4"W.-UP TO
4"HD#B001
4"W.-UP TO
4"FD#B001
(2)2"VT-UP
3"
3"W.-UP TO
3"HD-1
3" DS (UP)
4" C.O. ABOVE
3" DS (UP)
3" D.S. (UP)
4" C.O. ABOVE
AREA DRAIN ABOVE
5" D.S. (UP)
4" C.O. ABOVE
SPRINKLER DRAIN UP
AREA DRAIN ABOVE
AREA DRAIN ABOVE
4" C.O. ABOVE
4" D.S (UP)
4" C.O. ABOVE
4" D.S. (UP)
3" C.O.
5" DS (UP)
5" D.S. (UP)
4" D.S.
3" F.D
1 1/4" SPRINKLER DRAIN
3" FD
CO
3" FD
FD
DUPLEX SUMP PUMPS
8" STORM
6" STORM
10" STORM
6" STORM
6" STORM
3"
6" STORM
10" STORM 10" STORM
3" STORM
3" STORM3" STORM
8" STORM
12" STORM
4" STORM 4" STORM
3" STORM
4" STORM
3" STORM
3" STORM
12" STORM
15" STORM
10" STORM
8" STORM
3" STORM
15" STORM
6" STORM
15" STORM
3" STORM
4" STORM
4" STORM
3" STORM
3" STORM
8" COPPER
LINES
6" COPPER
LINES
2" STORM
3" SAN
3"
3" SAN
3"
3" STORM
6"
6"
3"
TO STORM SEWER
97,900 SQ. FT.
INV. ELEV. 1126.59
FD
TRENCH DRAIN
C.O.
CO
OFFSET AT CLG
4" SAN UP
CO
CO
5" SAN
5" SAN
6" SAN
5" SAN
5" SAN
4" SAN
4" SAN
3" SAN
5" SAN
3" SAN
5" SAN
4" SAN
4" SAN
4" SAN UP
4" SAN UP
4" SAN UP
4" SAN UP
4" SAN UP
4" SAN UP
4" SAN
4" SAN
4" SAN
3" SAN
4" SAN
3" SAN UP
3" SAN
WCO
WCO
3" OS
2" SAN
3" SAN
3" SAN
2" SAN 2" SAN
5" SAN
4" SAN
CO
2" SAN
4" SAN
CO
3" SAN
3" SAN
3" SAN
4" SAN
4" SAN
2" SAN
3" SAN
2" SAN
3" SAN
3" SAN
3" SAN
CO
3"CO
3"CO
3" SAN
C.O
4" SAN
4" SAN
2" SAN
4" SAN
4" SAN
3" SAN
3" SAN
4" SAN
4" SAN
2" SAN
W-UP/DN
3" SAN
CO
6" STORM
CO
3" SAN
CO
4" STORM UP
4" STORM
STORM MANHOLE
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
A
B
C
D
E
12347828262524232120 1.3 0.7
B.4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:3
P
M
B.V.L. K.K.S.
PL101
SUB-BASEMENT SANITARY PIPING
PLAN
DWG. 89 OF 147
N
1/8" = 1'-0"PL101
SUB-BASEMENT SANITARY PIPING PLANF1
RA
M
P
COILING OH
DOOR
COILING OH
DOOR
LIFT
SLOPED CEILING
COILING OH FABRIC
DOOR
TA
PI
PE
CH
AS
E
COILING OH
DOOR
LIFT
COILING OH
DOOR
EXTERIOR
PLATFORM
EXTERIOR
HEATED
SLOPED
WALKWAY
FE
FE FIRE
EQUIP
FIRE
EQUIP
UP
STAIR 3
MECH
SHAFT
FD
FD
FD
LOBBY
ELEVATOR
B224
BREAKOUT
STOCK /
B287
DECONTAMINATION
B295
PACKAGING
PREPARATION
B291B
STERLIZER
B291C
RECEIVING
SHIPPING &
B274
SHREDDER RM.
RECYCLING &
B278
STORAGE
WAREHOUSE
B298
EQUIP.
NON-EXP
B298A
LOGISTICS
STORAGE
B231
ROOM
MECH.
B224C
EQUIPMENT
ELEVATOR
B224B
ROOM
MECHANICAL
B224A
LOCKERS
B297
CHUTE
LAUNDRY
B230
ACCESS
MECH.
B227
ACCESS
MECH.
B295A
ROOM
MECH.
B231B
DATA
B296
C O
R R
ID
O
R
B
9C -1
VESTIBULE
B276
C O
R R
ID
O
R
B
9D -1
CORRIDOR
B299B-1
LOUNGE
B226
LOCKER
B226A
SHOWER
B226C
TOILET
B226B
COOLER
MORGUE
B273
O2 STOR
B268
EQUIP. RM.
ELECTRICAL
B278A
LOGISTICS
OFFICE
B298B
DOCK
LOADING
B272
@2" 1'-0""4 //1
(2)4"RC-UP
2"VT-UP
4"FD-1
F1
PK501
DRAINTILE
SUMP/PUMP
2"
4"
4"
2"W.-UP TO S#1404
AND S#1405
2"W.-UP
TO S#1494
2"W.-UP
TO S#1412
3"W.-UP TO
JC#1416
2"W.-UP TO
FD#1418
4"W.-UP TO
WC#1410
2"W.-UP TO
FD#1410
2"W.-UP TO
L#1410
2"W.-UP TO
S#1407
2"W.-UP TO
S#1406
DSN-1
(SECONDARY)
4"W.-UP
(3)4"RC-UP
2"W.-UP
6"RC-DN
4"
6"
6"
6" 4"
4"4"
3"VT-DN
2"W.-UP TO S#1402
AND S#1403.
(OFFSET WASTE
ABOVE OVER BEAM)
W.CO
6"RC-DN TO
30" A.F.F.
(1139'-0" VER.)
4"FD-14"FD-1
2"VT-UP
2"W.-UP TO
L#1417, L#1418
2"W.-UP
4"W.-DN
2"W.-UP TO
EWC.#1401
3"
3"HD-1
2"VT-DN
PROVIDE UNISTRUT SUPPORT(S) FROM
SHAFT WALL IN MECHANICAL SHAFT.
COORDINATE LOCATION WITH
EXISTING CONDUIT
F.CO
4"W.-UP TO
WC#1418,
WC#1417
2"W.-UP
TO
FD#1417
C1
PK501
HWR
C1
PK501
HWR
3"VT-UP
(2)2"VT-DN
(2)2"VT-UP
3 FD
AREA DRAIN
4"FCO
3" STORM UP
5" STORM UP
4"FCO
2" VENT
3"VTR
1 1/2" VENT
3"VTR1 1/2" VENT
5" STORM
5" STORM UP
FD
FD
FD
FD
1 1/2" VENT
1 1/2" VT
CO
1 1/2" VENT
2" V-UP/DN
2" W
4" W
2" W
4" W UP & DN
4" S.P.
4" SP-VP.
3" SS
4" SS
4" SS
3" SS
4" SS
4" SAN
4" SAN
4" SAN
2" W UP TO SINK
4" W UP TO WC
4" W UP TO FD
2" W UP TO SINK
2" W UP
TO LAV
4" W UP TO WC
2" W UP
TO SINKS
4" SAN. RISER UP
4" W UP TO WC
1-1/2" W
UP TO SINK
1-1/2" W
UP TO SINK
CAP EXIST. 4"
SAN. RISER
BELOW FLOOR
EXIST. 2" W
UP TO SINK
EXIST. 2" SAN
EXIST. 4" SAN
EXIST. 4" SAN
EXIST. 4" SAN
4"
4" 3"
4" SAN. RISER UP
TO SECOND FLOOR
EXIST. 4" SAN
EXIST. 4" SAN
3"
2"
EXIST. 4" SAN
FCO
4"
3" V UP
CO
MAKE 6" CONNECTION
TO TRENCH DRAIN
6" SAN TO EXISTING
MANHOLE @ 1% MIN.
SLOPE (50'-0"±)
6" SAN, IE=1141.33'
IE=1141.17'
2" W UP
TO EMERG.
EYEWASH
2" W UP TO
VERNACARE UNIT
SAN
4"
4" RISER TO
SECOND FLOOR
4"
2" W UP
TO LAV
2" W UP
TO SINK
2" W UP
TO LAV
2" W UP
TO SINK
2" W UP
TO FD
2" W UP
TO SINK
2" W UP
TO SINK
3" W UP
TO FD
4" SAN UP
4" SS UP
1-1/2" W
UP TO LAV 4" W UP
1-1/2" W
UP TO SINK
4"
1-1/2" W
UP TO LAV
1-1/2" W
1-1/2" W
UP TO LAV
2" W UP
TO LAV
4" W UP
TO WC
EXISTING 4" SAN
1-1/2" W UP (TYP)
1-1/2" W
UP TO LAV
1-1/2" W
UP TO LAV
1-1/4" W UP TO EYEWASH
EXISTING 4" SAN
2"
EXISTING 4" SAN
EXISTING 4" SAN
EXISTING 4" SAN
FCO
S A
N1-1/2" W
UP TO LAV
3"
EXIST. 4" SAN RISER
4" SAN
4" V-UP
10" STORM
4" STORM
UP TO FCO
10" STORM
10" STORM
10" STORM
4" STORM UP
4" STORM UP
3" SS DN
1 1/2" VENT
UP/DN
4" OVERFLOW DISCHARGE
3'-0" ABOVE GRADE FLUSH TO
WALL WITH SPLASH GAURD.
4" STORM
4" STORM UP TO
RD-1 AND OD
4" STORM DN
2" W UP
TO FD
4"CW-UP
2"HW-UP
1"HWR-UP
2"CW-UP
1"HW-UP
1/2"HWR-UP
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
PIPE
BASEMENT
B001
STAIR
ST-1
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:3
P
M
B.V.L. K.K.S.
PL102
BASEMENT SANITARY PIPING PLAN
DWG. 90 OF 147
N
1/8" = 1'-0"PL102
BASEMENT SANITARY PIPING PLANF1
ALCOVE
UTILITY
SOILED
1267A
TOILET
PATIENT
1267B
GARAGE
AMBULANCE
LOCKERS
BREAK RM/
RM
EXAM
WORK RM
NURSE
ROOM
EXAM
RM
EXAM
RM
EXAM
RM
DECON
MEDICATION
UTILITY
SOILED
TOILET
PATIENT
RM
TREATMENT
RM
TREATMENT
ROOM
TREATMENT
MEDICATION
/SECURITY RM.
FIRE ALARM
TOILET
PATIENT
LOBBY
ELEVATOR
TOILET
1224A
ROOM
COAT
OFFICE
PHARMACY
PHARMACY
MAIN
VAULT
MED PREP
SECURE
TOILET
PATIENT
CLERKS
RM
EXAM
WORKRM
NURSE
RM
EXAM
ROOM
EXAM
RM
EXAM
SUPPLY
STERILE
ROOM
EXAM
ROOM
ANTE
1312A
STATION
NURSE
DICTATION
WORKRM
NURSE
RM
EXAM
RM
EXAM
LINEN
CLEAN
HOUSEKEEPING
TOILET
STAFF
ISOLATION
TREATMENT/
TREATMENT
SECURE
TOILET
WOMENS
LAB/EKG
BLOOD DRAW
LAB/EKG
BLOOD DRAW
PT. TOILET
1312B
EQUIPMENT
PHARMACIST
CLINICAL
DISPENSING
OUTPATIENT
CLOSET
HSKPG
HSKPG
ELIGIBILITY
ENROLLMENT &
AREA
WAITING
AREA
CLERK
ELECTRICAL
CONSULTING
PHARMACY
DATA
DATA & PHONE
1218A
EQUIPMENT
ELEVATOR
VESTIBULE
AREA
WAITING
CONSULTING
1218B
CONSULTING
1218C
TRIAGE
STORAGE
WHLCHR
VESTIBULE
MRI
1304A
TOILET
STAFF
1340A
RM
CHANGING
1304C
RM
CHANGING
1304B
VESTIBULE
MRI
ROOM
EXAM
TOILET
PATIENT
ALCOVE
SCALE
TOILET
MENS
STAIR4
STAIR3
ALCOVE
PYXIS
FIRE
EQUIP
LO
CK
ER
S
BASEMENT ROOF
BASEMENT ROOF
LDRY
CHUT
RM
EXAM
DNUP
UP
DN
VOLUNTEER
AREA
MECH.
CHASE
CARPET
CARPET TILE
TILE
MECH
SHAFT
FD
FE FE
WC-1
L-1
S-1
WC-1
L-1
L-1
WC-1
S-1
S-1 S-1S-1S-1
S-1
S-1
JC-1
2"FD-1
FD-1
(2)4"RC-UP
(2)4"RC-DN
3"VT-UP
2"VT-DN
4"W.-UP/DN
(2)4"RC-UP
4"W.-DN
(3)4"RC-DN
2"W.-UP TO
FD#2421
2"W.-UP TO L#2421
AND L#2420
2"FD-1
2"W.-UP TO
S#2412
2"W.-UP TO
L#2406
2"W.-UP TO
L#2407
2"W.-UP TO
L#2404
2"W.-UP TO
L#2405
2"W.-UP TO
L#2408
2"W.-UP TO
FD#2402
2"W.-UP TO
L#2403
4"W.-UP TO
WC#2402
2"W.-UP TO
FD#2421
3"VT-UP
4"RC-UP
4"
4"
4"
W.CO
3"VT-DN
2"W.-DN
W.CO
2"VT-DN
2"VT-UP
3"W.-DN
2"W.-UP TO
EWC#2498
(2)2"VT-DN
OFFSET
2"W.-DN
EWC-1
2"VT
1-1/2"VT
1-1/2"VT 2
1-1/2"VT
1-1/2"VT
1-1/2"VT
2"VT
1-1/2" 1-1/2" 2" 2" 2"
COORDINATE LOCATION WITH
NEW DUCTWORK, WATER
PIPING AND FIRE MAIN.
2"W.-UP TO
L#2403
CONNECT TO BAS.
2" V
V.P
V.P. (UP)
4" D.S.
V.P. (UP)
4" D.S.
2" VENT
2" VENT
1 1/2" VENT
V.P. (UP)
2" V UP
FINISH FLOOR ELEVATION = 1148.00'
2" V
2" V UP
CATCH BASIN
600 GALLON
HOLDING TANK
2" V-UP
1 1/4" V
1 1/2" V
2" V UP
C.O.
4" SS
4" SS
4" D.S.
2" SAN
4" SAN
4" SAN
1 1/2" SAN
2" SAN
4" SS
4" SAN
3" SAN
4" SS
2" SAN
3" FD
3" FD
4" W UP
4" SN DN CO
3" W& V UP
1-1/2" W DN
CO
4" W UP
1-1/2" W
1-1/2" W
4" W UP
2" W UP
1-1/2" W
2" W UP
1-1/2" W
4" W UP
4" W UP
1-1/2" W
1-1/2" W
4" W UP
2" W UP
1-1/2" W
1-1/2" W
1-1/2" W
1-1/2" W
2" W UP
1-1/2" W
1-1/2" W
4" W UP
1-1/2" W 1-1/2" W
1-1/2" W
1-1/2" W
1-1/2" W
2" W UP
1-1/2" W
1-1/2" W
1-1/2" W
4" W UP
CO
1-1/2" W
4" W UP
2" W UP1-1/2" W
4" SN UP
2"
3" 2"
4"
4"
4"
2" 4"
2"
2"
3"
4"
3" HUB OUTLET
4"
1-1/2" W
4"
CO
4" SN DN
2"
CO
4"
4" SN DN
4"
2" SAN
3" SAN
3" SAN
2" SAN
3" SAN
3" SAN
2" SAN
2" SAN
2" SAN
3" SAN
3"
SAN
3" SAN
2" SAN
2" SAN
2" SAN
2" SAN
2" SAN
1 1/2" SAN
3" W UP TO SS
4" W
UP TO
FD
4" SS/VP
4" SAN
2" SAN
3" SAN
2" SAN
2" SAN
3" SAN 3" SAN
4" SS UP
4" SAN
3" SAN
4" SS DN
2" SAN
4" SS
4" SS
3"
2"
3"
3"
2"
2"
4" ST DN
4" ST RISER
4" ST UP
EXIST. 5" ST UP/DN
4" ST UP
VERNACARE
4" SAN STACK
2" SAN
3" SS
3" SS DN
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
EXAM ROOM
1352 CONNECTION
CORRIDOR
CORRIDOR
ELECTRICAL
ROOM
IT ROOM (VA)
CONFERENCE
ROOM
STAIR
ST-1
MEDICAL
EQUIPMENT
STORAGE
TEAMLET
WORKSTATIONS
EXAM
EXAM
CLEAN
UTILITY
SOILED
HOLDING
HALLWAY
CORRIDOR
EXAM
EXAM
SUB-WAIT
EXAM
EXAM
CORRIDOR
PATIENT
TOILET
PATIENT
TOILET
STAFF TOILET
MENTAL
HEALTH
OFFICE
CLINICAL
PHARM
EXAM ROOM
EXAM ROOM
CLINICAL
PHARM
ALCOVE
EXAM ROOM
NURSE
WORKROOM
MENTAL
HEALTH
SOCIAL
WORKER
MENTAL
HEALTH
PSYCHOLOGIST
MENTAL
HEALTH
GROUP ROOM
H/W ALCOVE
TRIAGE
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
HSKP.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:4
P
M
B.V.L. K.K.S.
PL103
FIRST FLOOR SANITARY PIPING PLAN
DWG. 91 OF 147
N
1/8" = 1'-0"PL103
FIRST FLOOR SANITARY PIPING PLANF1
ULTRASOUND
ROOM
TECH. WORK
SUPPLY
CLEAN
VIEWING
PACS
TOILET
PT.
ROOM
CHANGING
HSKG
CONTROL
CT SCAN
CT SCAN
TOILET
PT.
HOT LAB
2254A
MEDICINE
NUCLEAR
DENSITY
BONE
CHUTE
LAUNDRY
UTILITY
ROOM
CONTROL
2263A
RADIOLOGY
SCANNER
GE CT
STORAGE
2263B
CLEAN
STERILE
CYSTOSCOPY
CLOSET
HSKG
MECHANICAL
MECHANICAL
2307A
LOBBY
ELEVATOR
PHONE
DATA &
2218 ALCOVE
EQUIP.
2230A
CORRIDOR
2230P
ROOM
TECH WORK
C2-2
CORRIDOR
SOCIAL
WORKER
ACCUPUNCTURE
EXAM ROOM
DATA
CLOSET
ACCUPUNCTURE
EXAM ROOM
EYE PRE-
TREATMENT
EYE PRE-
TREATMENT
OFFICE
STAFF
LOUNGE
STERILE
SUPPLY
CLEAN
SUPPLY
SOCIAL
WORKER
2335A
PATIENT
TOILET
CHEMOTHERAPY
MENTAL HEALTH
EXAM
HSKG CLST
ELECTRICAL
ROOM
LANE
ROOM
LANE
ROOM
LANE
ROOM
EYE
INSTRUMENTS
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
TELE-HEALTH
OFFICE
TELE-HEALTH
EXAM RM
TELE-HEALTH
EXAM RM
MENS
TOILET
WAITING
AREA
WOMENS
TOILET
CLERKS
AREA
2374A
STAFF
WORK AREA
CORRIDOR
STAFF
TOILET
SUB-WAIT
AREA
WOMENS
HEALTH EXAM 2352
TOILET
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
WOMENS
HEALTH EXAM
FAMILY
LOUNGE
2338A
FAMILY
RESTROOM
ONOCOLOGY
EXAM/OFFICE
ONOCOLOGY
EXAM/PROC.
SOILED
LINEN
2261A
CONTROL
ROOM
CLERK
CHECK-IN
WAITING
AREA
FEMALE
TOILET
MALE
TOILET
C2-1
CORRIDOR
AREA
DUMBWAITER
/CART ALCOVE
2110B
SCRUB
ALCOVE
2252P
CORRIDOR
CORRIDOR
PASSENGER
ELEVATOR
PASSENGER
ELEVATOR
STAIR 3
UP
DN
STAIR 4
UP
DN
MECH
CHASE
MECH.
SHAFT
CHASE
MECH.
SHAFT
CHASE
FIRST FLOOR ROOF
FIRST FLOOR ROOF
BASEMENT ROOF
BASEMENT ROOF
WC-1
WC-1
L-1
S-3
L-1
L-1
WC-1
L-1
L-1
3"VT-UP
4"VT-TR
L-1
L-1
L-1
3"VT-DN
2"FD-1
2"FD-1
2"FD-1
3"VT-DN
4"W.-DN
L-1
3"
3"
3"RC-UP
3"RC-UP
FRPS
4"RC-DN
3"
(2)4"RC-DN
3"RC-UP
TO 3"RD-2
3"RC-UP
TO 3"RD-1
3"RC-UP
TO 3"RD-1
W.CO 2"VT-DN
2"W.-DN
3"RC-UP
TO 3"RD-2
3"RC-UP
TO 3"RD-1
3"RC-UP
TO 3"RD-1
(2)4"RC-DN
W.CO
2"W.-DN
3"RC-UP
TO 3"RD-2
EWC-1
3"RC-UP
TO 3"RD-2
3"VT-UP
4"VT-TR
2"VT-UP
(2)2"VT-UP
2"
2"
4"
4"W.-UP TO
FD.#3331
4"W.-UP TO
HD.#3331
4"W.-UP TO
HD.#3331
CONNECT TO BAS.
FD
1 1/2" VENT
5" DS
4"VTR
3" V
4" ST DN
4" ST DN
4" ST RISER
4" ST DN
4" ST UP
3" V RISER
3" V DN
1-1/2" V
1-1/2" V
2" V
2" V
2" V
2" V
2" V
1-1/2" V
3" V
3" V
4" VTR
3" V DN
1-1/2" V
2" V
2" V
2" V
2" V
2" V
1-1/2" V
2" V
1-1/2" V
1-1/2" V
2" V
3" V
4" RD
4" RD
4" RD
4" RD4" RD
4" ST UP
4" ST DN
CO
4" ST
CO
3" V UP
CO
4"
EXIST. 5" ST
EXIST. 5" ST DN
EXIST. 6" ST
EXIST. 4" ST
3" V UP
4"
4"
3"
4" ST UP
1 1/2" V
1 1/2" VENT
3" SAN
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2"
VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
1 1/2" VENT
3" VS
DN
3" VENT
2" VENT
2" VENT
1 1/2" VENT 3" V
DN, 4"
VTR
3" V
DN, 4"
VTR
1-1/2" V
1-1/2" V
ACCESS PANEL(S)
2"RD
2"RD
4" SS
2" SAN
2" SAN
4" SAN STACK
4" SAN STACK
4" SAN STACK
4" SAN STACK
4" SAN STACK
4" SAN
2" SAN
4"CO
3" SAN STACK
4" SAN STACK
4" SS
2" SAN UP
TO L-1(2)
2" SAN UP TO L-1(2)
4" SAN UP TO WC-1
2" SAN
UP TO S-1
2" SAN UP TO
SH-1
2" SAN UP
TO SH-1
4"CO
4" SAN
4" SAN
4" SAN
4" SAN
2" SAN
4"CO
4" SAN UP TO
WC-1
2" SAN
2" SAN
1 1/2" SAN
3" WASTE STACK
PLUMBING PLAN NOTES
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO BE REMOVED,
EXISTING PLUMBING STACKS/RISERS/ROOF CONDUCTOR(S) TO REMAIN -NO CHANGE.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
BACK TO STACK/RISERS/MAINS. CAP OR EXTEND.
REMOVE PLUMBING FIXTURE OR EQUIPMENT. REMOVE RELATED SERVICE PIPING
REMOVE PLUMBING FIXTURE OR EQUIPMENT. CAP SERVICE PIPING BEHIND WALL.
EXISTING SERVICE PIPING TO FIXTURE(S) ABOVE -NO CHANGE.
RELOCATED OR REVISED TO SUIT NEW REMODELING WORK.
AS SHOWN. CAP OR EXTEND.
MAKE NEW CONNECTION TO EXISTING PIPING.
PLUMBING FIXTURE OR EQUIPMENT TO REMAIN -NO CHANGE.
FUTURE POINT OF CONNECTION.
2.7 0.0
D.0
C.0
A.3
B.0
1.5 0.50.8
HBPC
WORKROOM
STAFF TOILET
STAFF TOILET
CORRIDOR
IT ROOM
(VENDOR)
ELECTRICAL
ROOM
2419 IT ROOM (VA)
SUB-WAIT
SUB-WAIT
HALLWAY
PATIENT
TOILET
HALLWAY
TELEHEALTH
EXAM
TELEHEALTH
EXAM
TELEHEALTH
EXAM
TELEHEALTH
EXAM
TELEHEALTH
EXAM
TELEHEALTH
WORKROOM
TELEHEALTH
EXAM
CORRIDOR
STAIR
ST-1
OFFICE
(NURSE
MANAGER)
OFFICE
(ACOS)
RECEPTION
OFFICE
(HBPC)
OFFICE
(TELEHEALTH)
CDE
CDE
2364 CDE
WC ALCOVE
A
B
C
D
E
F
12347828262524232120 1.3 0.7
B.4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re
/V A
P L
U M
B .r v t
/4 /2
:2
:4
P
M
B.V.L. K.K.S.
PL104
SECOND FLOOR SANITARY PIPING
PLAN
DWG. 92 OF 147
N
1/8" = 1'-0"PL104
SECOND FLOOR SANITARY PIPING PLANF1
STORAGE
HEALTH
TELE-
ROOM
EXAM
HEALTH
TELE-
MECH
3244A
LOBBY
ELEVATOR
ROOM
EXAM
ROOM
EXAM
AREA
WAITING
ROOM
EXAM
CORRIDOR
3299B-1
ROOM
EXAM
ROOM
MECHANICAL
CHIEF, DENTAL
X-RAY
CONTROL
3228A
ROOM
WAITING
PASSAGE
3237A
PASSAGE
TRAINING ROOM
NURSE EDUCATION
OFFICE
NURSE EDUCATI
PASSAGEWAY
TRAINING ROOM
NURSE EDUCATION
STORAGE
NESS/KITCHEN
TOILET
3246A
TOILET
3250A
SUPPLY
STERILE
SUPPLY
CLEAN
UTILITY
SOILED
ROOM
EXAM
STAFF OFFICE
TELE-HEALTH
OFFICE
MSA
CORRIDOR
3299C-1
CORRIDOR
DUCT
FIRST FLOOR ROOF
FIRST FLOOR ROOF
BASEMENT ROOF
FIRST FLOOR ROOF
FIRST FLOOR ROOF
FIRE
EQUIP
LDRY
CH…