ATTACHMENT 3 - Drawings 2 of 7.pdf
PDF 17 MB Posted
- Solicitation number
- 36C77621B0005
About this file
This notice provides details for a federal construction contract opportunity for the Department of Veterans Affairs. The solicitation will be for a single firm-fixed-price contract to complete an addition and renovation project at the Oscar G. Johnson VA Medical Center in Iron Mountain, Michigan. Work will include expanding primary care facilities by 10,000 square feet as well as renovating approximately 1,100 square feet of existing space on the first floor. The project scope encompasses architectural, site, structural, fire protection, HVAC, plumbing, electrical, earthwork, exterior utilities, and other construction aspects. The solicitation will be issued as an Invitation for Bid evaluated according to procedures in the solicitation. It is a total Service-Disabled Veteran-Owned Small Business set-aside with a North American Industry Classification System code of 236220 and size standard of $39.5 million. The performance period is approximately 546 calendar days from the notice to proceed. The magnitude of construction is between $5 million and $10 million. The solicitation will be issued in March 2021.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
/F1 AE150-1/F1 AE150-1
F A E -1
F A E -1
EXPOSED
STRUCTURE
B001
ST-1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:4
P M
DPD JAP
AE150
PIPE BASEMENT REFLECTED CEILING
PLAN
DWG. 29 OF 147
N
1/8" = 1'-0"AE150
BASEMENT REFLECTED CEILING PLANF2
4'0 8' 12'2'
1415 1414
1402 1403 1404 1405
ST-1
1418 1417
1358 1352
/F1 AE151-1/F1 AE151-1/F1 AE151-3/F1 AE151-3
/F1 AE151-2/F1 AE151-2/F1 AE151-4/F1 AE151-4
F A E -2
F A E -4
F A E -2
F A E -4
F A E -1
F A E -3
F A E -1
F A E -3
(NO WORK)
(NO WORK)
(NO WORK)(NO WORK)
(NO WORK)
(NO WORK)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:0
P M
DPD JAP
AE151
1ST FLOOR REFLECTED CEILING PLAN
DWG. 30 OF 147
N
1/8" = 1'-0"AE151
1ST FLOOR REFLECTED CEILING PLANF2
ST-1
2419 2418
2416 2417
2413 2414
24062405
23642362
24202421
(NO WORK)(NO WORK)
(NO WORK)
/F1 AE152-1/F1 AE152-1
F A E -1
F A E -1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:0
P M
DPD JAP
AE152
2ND FLOOR REFLECTED CEILING PLAN
DWG. 31 OF 147
N
1/8" = 1'-0"AE152
2ND FLOOR REFLECTED CEILING PLANF2
EXPOSED STRUCTURE
ST-1
B001
C2
AE502
C2
AE502
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:5
P M
DPD JAP
AE150-1
PIPE BASEMENT REFLECTED CEILING
PLAN - ZONE 1
DWG. 32 OF 147
N
1/4" = 1'-0"AE150-1
BASEMENT REFLECTED CEILING PLAN - ZONE 1F1
0 2' 4' 6'1'
2'-0"
GYP
8' - 4"
EP2
ST-1
1402 1403 1404 1405
1418 1417
GYP
8' - 4"
EP2 GYP
8' - 4"
EP2
GYP
8' - 4"
EP2
GYP
8' - 4"
EP2
ACT
8' - 4"
ACT
8' - 10"
2ACT
8' - 10"
2ACT
8' - 10"
2ACT
8' - 10"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
8' - 2"
1415 1414
EXPOSED
CEILING
EXPOSED
CEILING
ACT
9' - 0"
GYP
8' - 0" P1
ACT
9' - 0"
GYP
8' - 10"
P8
ACT
9' - 0"
ACT
8' - 4"
GYP
7' - 11"
P1
GYP
8' - 10"
P8
GYP
8' - 3"
P8
GYP
8' - 0" P1
GYP
8' - 0" P1
/F1 AE151-3
/F1 AE151-2/F1 AE151-2/F1 AE151-4
F
A
E
-2
F
A
E
-4
F
A
E
-3
F
A
E
-3
EXPANSION
JOINT COVER
2'-0"
BACKING ABOVE TILE
FOR CUBICLE TRACK
SUPPORT, TYP.
ACT
8' - 0"
ACT
7' - 10"
EX
REMOVE, SALVAGE AND
RE-INSTALL CEILINGS AT
NEW SPECIFIED HEIGHT.
REPLACE ANY DAMAGED
MATERIALS
ACT
8' - 0"
EX
1340A
ACT
9' - 0"
F1
AE501
ACT
8' - 10"
E3
AE501
E3
AE501
E2
AE501
E2
AE501
E3
AE501
E2
AE501
E3
AE501
E2
AE501
E2
AE501
ACT
8' - 4"
GYP
8' - 3"
GYP
8' - 9 1/4"
ACT
8' - 10"
/8
E1
AE501
GYP
8' - 3"
P8
GYP
8' - 9" P8
OPERABLE
PARTITION
D1
AE501
E2
AE505
D9
AE505
E2
AE505
D9
AE505
B9
AE505
PROVIDE CONTROL JOINT
AT ALL FACES OF SOFFIT
PROVIDE CONTROL JOINT
AT ALL FACES OF SOFFIT
PROVIDE CONTROL JOINT
AT ALL FACES OF SOFFIT
E3
AE501
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:1
P M
DPD JAP
AE151-1
1ST FLOOR REFLECTED CEILING PLAN
- ZONE 1
DWG. 33 OF 147
N
1/4" = 1'-0"AE151-1
1ST FLOOR REFLECTED CEILING PLAN - ZONE 1F1
GYP
8' - 10"
P8
ACT
9' - 0"
2x2
ACT
9' - 0"
2x2
/F1 AE151-1/F1 AE151-1/F1 AE151-3
/F1 AE151-4
F
A
E
-4
F
A
E
-4
F
A
E
-1
F
A
E
-3
E3
AE501
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:2
P M
DPD JAP
AE151-2
1ST FLOOR REFLECTED CEILING PLAN
- ZONE 2
DWG. 34 OF 147
N
1/4" = 1'-0"AE151-2
1ST FLOOR REFLECTED CEILING PLAN - ZONE 2F1
13521358
ACT
9' - 0" 2x2
ACT
9' - 0"
2x2
/F1 AE151-1
/F1 AE151-2/F1 AE151-4/F1 AE151-4
F
A
E
-2
F
A
E
-4
F
A
E
-1
(NO WORK)(NO WORK)
(NO WORK)
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:3
P M
DPD JAP
AE151-3
1ST FLOOR REFLECTED CEILING PLAN
- ZONE 3
DWG. 35 OF 147
N
1/4" = 1'-0"AE151-3
1ST FLOOR REFLECTED CEILING PLAN - ZONE 3F1
GYP
8' - 0"
P1
ACT
9' - 0" 2x2
ACT
9' - 0"
2x2
ACT
9' - 0"
2x2
ACT
9' - 0" 2x2
/F1 AE151-1/F1 AE151-3/F1 AE151-3
/F1 AE151-2
F
A
E
-2
F
A
E
-2
F
A
E
-1
F
A
E
-3
(NO WORK)
(NO WORK)
(NO WORK)
(NO WORK)
E2
AE501
E2
AE501
D1
AE501
EXPANSION JOINT TO MATCH
LOCATION AND WIDTH OF
EXISTING FLOOR JOINT
MODIFY EXISTING 8'-4" CEILING
AND TRADES EQUIPMENT TO
ACCOMMODATE NEW SOFFIT
MODIFY EXISTING 8'-4" CEILING
AND TRADES EQUIPMENT TO
ACCOMMODATE NEW SOFFIT
W
IT
H F
P T
R A
D E
V
E R
IF
Y
E2
AE501
GYP
8' - 0"
PT
PAINT SOFFIT TO MATCH
ADJACENT SOFFIT
V
E R
IF
Y
W
IT
H P
L U
M B
IN
G
A
N D
F P
T R
A D
E S
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:4
P M
DPD JAP
AE151-4
1ST FLOOR REFLECTED CEILING PLAN
- ZONE 4
DWG. 36 OF 147
N
1/4" = 1'-0"AE151-4
1ST FLOOR REFLECTED CEILING PLAN - ZONE 4F1
EXPOSED
CEILING
EXPOSED
CEILING
GYP
7' - 10" P8
GYP
7' - 10"
P1
ACT
8' - 0"
ACT
9' - 0"
GYP
8' - 0" P1
GYP
9' - 0"
EP2
GYP
9' - 0"
EP2
ACT
9' - 0"
GYP
9' - 0"
PT8
ST-1
2413 2414
2499 2498
24972496
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
9' - 0"
ACT
8' - 6"
ACT
9' - 0"
ACT
9' - 0"
ACT
8' - 6"
ACT
9' - 0"
4ACT
9' - 0"
ACT
9' - 8"
EXPOSED
CEILING
GYP
9' - 0"
EP2
EXPANSION
JOINT COVER
GYP
8' - 0"
P1
SOFFIT ABOVE AT
PENTHOUSE ROOF
E2
AE501
E2
AE501
E2
AE501
E2
AE501
E2
AE501
E2
AE501
GYP
8' - 5"
GYP
8' - 9 3/4"
ACT
8' - 6"
GYP
8' - 5" P8
D1
AE501
E2
AE701
GYP
8' - 0"
P1
TYP.
2'-0"
E3
AE501
D9
AE505
E2
AE505
D2
AE505
D9
AE505
B9
AE505
C2
AE505
ALIGN GRID WITH
WALL CORNER
GYP
7' - 11"
P8
E3
AE501
/2
1. UNLESS DIMENSIONED OTHERWISE ON THIS PLAN, CEILINGS
GRIDS ARE CENTERED IN ROOM IN BOTH DIRECTIONS.
2. SEE I001 FOR CEILING FINISH TYPE
3. COORDINATE/VERIFY LOCATION OF CEILING MOUNTED LIGHTS
WITH OWNER PRIOR TO INSTALLATION OF SUPPORT STRUCTURE.
4. WHERE EXISTING PARTITIONS ARE SHOWN TO HAVE A FIRE OR
SMOKE RATING, THE CONTRACTOR SHALL PROVIDE THE
REQUIRED PENETRATION PROTECTION FOR ALL NEW
PENETRATIONS THROUGH THE PARTITION. REPORT ANY
EXISTING VOIDS WHICH REQUIRE PATCHING, UNDER ADDITIONAL
SCOPE OF WORK.
5. CONTRACT WORK INCLUDES ALL CEILING MOUNTED ITEMS OR
DEVICES SHOWN ON THIS PLAN AND AS SHOWN ON THE PLANS
OF OTHER TRADES. THIS DRAWING DOES NOT RELIEVE
CONTRACTOR'S RESPONSIBILITY TO INDIVIDUALLY COORDINATE
THEIR WORK WITH OTHER TRADES.
GENERAL CEILING PLAN NOTES:
ARCHITECTURAL REFLECTED
CEILING PLAN NOTES
ACOUSTICAL TILE CEILINGS
GYPSUM BOARD CEILINGS
CEILING HEIGHT (PARENTHESIS INDICATES
EXISTING CEILING HEIGHT)
CEILING TYPE/FINISH
CEILING MATERIAL
ACT: ACOUSTICAL TILE CEILING
ESA: EXPOSED STRUCTURE ABOVE
GYP: GYPSUM BOARD
SMP: PAINTABLE SHEET METAL PANELS BY
MECHANICAL TRADE
CEILING HEIGHT (PARENTHESIS
INDICATES EXISTING CEILING HEIGHT)
8'-0"
8'-0"
MATERIAL AND SYMBOLS LEGEND:
INDICATES LOCATION OF CUT CEILING TILES
REQUIRED TO CENTER GRID PATTERNS IN
CORRIDORS
CUBICLE TRACK
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 2 HOUR FIRE
DOORS: 90 MINUTE FIRE
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE
FIRE COMPARTMENT DIVISON
WALLS: 2 HOUR FIRE AND SMOKE RESISTANT
DOORS: 90 MINUTE FIRE AND SMOKE RESISTANT
OPENINGS: NOT PERMITTED
DAMPERS: 90 MINUTE FIRE AND SMOKE RESISTANT
STAIR, SHAFT, OR HAZARDOUS AREA SEPARATION
WALLS: 1 HOUR FIRE
DOORS: 45 MINUTE FIRE
OPENINGS: 45 MINUTE PROTECTION
DAMPERS: 90 MINUTE FIRE AT NON-SPRINKLED
SMOKE COMPARTMENT DIVISON
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION,
45 MINUTE AT 1 HOUR RATED ROOMS
DAMPERS: SMOKE RESISTANT
(IN NEW CONSTRUCTION REQUIRED BY IBC)
ONE HOUR SMOKE RESISTANT PARTITION
(NON-SPRINKLED COMPARTEMENT)
WALLS: 1 HOUR FIRE AND SMOKE RESISTANT
DOORS: 20 MINUTE CONSTRUCTION AND SMOKE RESISTANT
OPENINGS: 20 MINUTE PROTECTION
SMOKE RESISTANT PARTITION (SPRINKLED COMPARTMENT)
WALLS: SMOKE RESISTANT
DOORS: SMOKE RESISTANT AND POSITIVE LATCHING,
(EXCEPT TOILET ROOMS, ECT.)
OPENINGS: CANNOT EXCEED 80 SQ. IN. WITHOUT PROTECTION
FIRE SEPARATION LEGEND
SYMBOLS KEY
HVAC
FIRE PROTECTION
ARCHITECTURAL
ACCESS PANEL
RETURN GRILLE
SUPPLY DIFFUSER
RETURN GRILLE
SUPPLY DIFFUSER
GYPSUM BOARD CEILING
AP
PAINTED SHEET METAL PANELP.
CONCEALED PENDENT SPRINKLER HEAD
CEILING COORDINATION
PLAN LEGEND
EXHAUST GRILLE
SUPPLY DIFFUSER
PENDENT SPRINKLER HEAD
OS
S
S
S
N
2X4 LIGHT FIXTURE -
RECESSED / SURFACE
RECESSED DOWNLIGHT,
SURFACE / PENDANT
1X4 LIGHT FIXTURE -
RECESSED / SURFACE
EXIT SIGN - SINGLE / DOUBLE FACE
OCCUPANCY SENSOR
CEILING MOUNTED SPEAKER / STROBE
SMOKE DETECTOR
SPEAKER RECESSED
SPEAKER SURFACE
WIRELESS DATA ACCESS POINT
CORRIDOR DOME LIGHT
ELECTRICAL
2X2 LIGHT FIXTURE -
RECESSED / SURFACE
CEILING MOUNTED SECURITY CAMERA
(DOME TYPE)
S
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
KEY PLAN
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
ZONE 1
ZONE 2
ZONE 3
ZONE 4
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:1
P M
DPD JAP
AE152-1
2ND FLOOR REFLECTED CEILING PLAN
- ZONE 1
DWG. 37 OF 147
N
1/4" = 1'-0"AE152-1
2ND FLOOR REFLECTED CEILING PLAN - ZONE 1F1
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0C.0
BASEMENT
1137' - 0"
B.0
PARAPET
1178' - 11 1/2"
C6
AE301
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
EGRESS
LANDING
1142' - 0"
PRECAST ARCHITECTURAL
CONCRETE TO MATCH EXISTING
BRICK TO MATCH EXISTING
NEW RETAINING
WALL - SEE
SHEET C100
F6
AE301
F3
AE351
F7
AE351
A B.4
22'-0" 4'-0"
C.J. C.J.
C.J.
BUILDING
SECTION
6'-0" W X 4'-0" H
BLAST RATED
LOUVER
C.J. SEE TYP.--------------
B5
AE503
BUILDING
SECTION
WALL
SECTION
WALL
SECTION
F6
AE503
F8
AE503
6'-0" W X 4'-0" H
BLAST RATED
LOUVER
B
B
A
GUARDRAIL -
SEE SHEET C100
GUARDRAIL -
SEE SHEET C100
EXISTING
(NOT SHOWN
FOR CLARITY) NEW WORK
6'-0" 4'-0" 7'-0" 4'-0" 4'-0" 4'-0"
1139' - 4"
C2
AE502
2'-0"
F8
AE602
F9
AE602
C9
AE502
B3
AE502
BRICK LEDGE RISE IS 8", TYP. UNO
1140' - 0"1
3" BLAST RESISTANT
INSULATED METAL
WALL PANEL
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
0.0
BASEMENT
1137' - 0"
C2
AE301
PARAPET
1178' - 11 1/2"
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
0.5
F9
AE351
PRECAST ARCHITECTURAL
CONCRETE TO MATCH EXISTING
BRICK TO MATCH EXISTING
REMOVE AND
REPLACE BOLLARD
EXISTING DRIVEWAY
TO REMAIN
EXISTING
GARAGE TO
REMAIN
0.80.7 F4
AE352
EXISTING
PRECAST
4'-0" 24'-0"
C.J. C.J.
BUILDING
SECTION WALL
SECTION
WALL
SECTION
NEW FLASHING
EXISTING
(NOT SHOWN
FOR CLARITY)NEW WORK
E5
AE502
LOCATION OF
MOVED LADDER
RELOCATED LOUVER IN
EXISTING WALL, MATCH
ELEVATION OF EXISTING
LOUVER, LINE WITH EDGE
OF EXISTING DOOR
C9
AE502
3" BLAST RESISTANT
INSULATED METAL
WALL PANEL
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
2.7 0.0
BASEMENT
1137' - 0"
C2
AE301
1.5
PARAPET
1178' - 11 1/2"
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
0.5
EGRESS
LANDING
1142' - 0"
F2
AE301
F5
AE351
12347 56 F1
AE352
PRECAST ARCHITECTURAL
CONCRETE TO MATCH EXISTING
BRICK TO MATCH EXISTING
19'-4" W X 5'-2" H
NEW LOUVER IN
EXISTING WALL
EXISTING
ELEVATION
EXISTING
TRANSFORMERS
TO REMAIN
INFILL
REMOVED
LOUVER
1.3 0.8 0.7
4'-0"16'-0"4'-0" 16'-0" 15'-8"
C.J. C.J. C.J.C.J.C.J.C.J.
5'-4" W X 4'-0" H
BLAST RATED
LOUVER
BUILDING
SECTION
WALL
SECTION
WALL
SECTION
BUILDING
SECTION
C
16'-0"19'-8"10'-0" 20'-0" 5'-8" 25'-0"
1139' - 4"
8"
F8
AE602
AE502
C2
AE502
C2
F6
AE602
F2
AE503
-------------- SIM.
TYP.
C2
AE505
C9
AE502
BRICK LEDGE RISE IS 8", TYP.
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0 C.0 A.3
BASEMENT
1137' - 0"
PARAPET
1178' - 11 1/2"
C6
AE301
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
EGRESS
LANDING
1142' - 0"
F6
AE301
F7
AE351
B CR P O N
PRECAST ARCHITECTURAL
CONCRETE TO MATCH EXISTING
BRICK TO MATCH EXISTING
EXISTING
GARAGE TO
REMAIN
EXISTING
ELEVATION
EXISTING
MECHANICAL
LOUVER
B.4 A.9
E.J. EXISTING PRECAST
AND STONE STRING
COURSE
EXISTING
PRECAST
2'-4" 9'-8" 18'-0" 18'-4" 6'-8" 4'-0"
C.J. C.J. C.J.C.J. C.J.
BUILDING
SECTION
WALL
SECTION
BUILDING
SECTION
6'-0" W X 4'-0" H
BLAST RATED
LOUVER
E7
AE501
E7
AE501
E7
AE501
D
D
10'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0" 6'-0"
F9
AE602
C2
AE502
F3
AE352
WALL
SECTION
B3
AE502
C9
AE502
BRICK LEDGE RISE IS 8", TYP.
3" BLAST RESISTANT
INSULATED METAL
WALL PANEL
BOTTOM OF STUB WALL,
TYP. (DASHED LINE)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:2
P M
DPD JAP
AE201
EXTERIOR ELEVATIONS
DWG. 38 OF 147
1/8" = 1'-0"AE201
C7 WEST BUILDING ELEVATION
1/8" = 1'-0"AE201
F7 NORTH BUILDING ELEVATION
1/8" = 1'-0"AE201
C1 SOUTH BUILDING ELEVATION
1/8" = 1'-0"AE201
F3 EAST BUILDING ELEVATION
4'0 8' 12'2' 4'0 8' 12'2'
4'0 8' 12'2'4'0 8' 12'2'
1'-6"1'-9"
3'-8"
HOOK (CC)
HOOK (CC)
HAND SANITIZER (VC)
HOOK (CC)
HOOK (CC)
1'-5" 8" 7"
F
1'-2"
PL1
SS1
PL1
SHARPS
CONTAINER (VC)
PAPER TOWEL
DISPENSER (VC)
SOAP
DISPENSER (VC)
CCB
SINK BY PLUMBING
TRADE
SA
C8
AE601
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
3'-5"
F3
AE701
GLOVES DISPENSER
(VC)
3'-0"
BACKING ABOVE TILE
FOR CUBICLE TRACK
SUPPORT, TYP.
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
C8
AE601
MIRROR, 18x60 (CC)
EQ EQ
C8
AE601
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
OPEN
BEYOND
2724 F
F
PL1
PL1
PL1
PL2
CG1
F
F
PL1
PL1
PL1
PL2
INTERIOR ELEVATION NOTES
1. REFER TO TYPICAL MOUNTING HEIGHTS SHEET G003
2. REFER TO ROOM FINISH SCHEDULE FOR ADDITIONAL FINISH
INFORMATION
3. FOR CASEWORK LEGEND, SEE SHEET AE701
4. EQUIPMENT DESIGNATION AS FOLLOWS (U.N.O.):
VV - VA PROVIDED / VA INSTALLED
VC - VA PROVIDED / CONTRACTOR INSTALLED
CC - CONTRACTOR PROVIDED / CONTRACTOR INSTALLED
SOAP DISPENSER (VC)
PAPER TOWEL
DISPENSER (VC)
1'-5" 9" 7"
F
PL1
SS1
SINK BY
PLUMBING TRADE
2734 2434
F3
AE701
2'-8"
1'-3" 1'-7" 2'-0"
STAINLESS STEEL SINK
W/ INTEGRAL
EYE-WASH
PAPER TOWEL
DISPENSER (VC)
SHARPS CONTAINER
(VC)
4'-0"
SA
CBKS
SS1
SINK BY
PLUMBING TRADEF3
AE701
3'-0"
GLOVES DISPENSER
(VC)
SOAP DISPENSER (VC)
1'-0"
MOP AND BROOM
HOLDER (CC)
EQ EQ
1'-9"
CHEMICAL DISPENSER
(VC)
10"1'-6"
MIRROR, 24x36 (CC)
TOILET SEAT COVER
DISPENSER (CC)
3-PIECE GRAB BAR
(CC)
PAPER TOWEL
DISPENSER (VC)
EQ EQ
FIXTURE WALL, SEE
INTERIOR SHEETS
1'-0"
SOAP DISPENSER (VC)
TILE WAINSCOT, SEE
INTERIOR SHEETS
1'-9"
2'-8"
HOOK (CC)
BABY CHANGING STATION (CC)
HOOK (CC)
(PATIENT TOILETS ONLY)
TILE WAINSCOT, SEE
INTERIOR SHEETS1'-6"
SANITARY NAPKIN
DISPOSAL (CC)
3-PIECE GRAB BAR
(CC)
SANITARY NAPKIN
DISPENSER (CC)
1'-8"
TILE WAINSCOT, SEE
INTERIOR SHEETS
TOILET TISSUE
DISPENSER (VC)
1'-5" 1'-8" 8"
GLOVES DISPENSER
(VC)
PAPER TOWEL
DISPENSER (VC)
SOAP DISPENSER (VC)
F
PL1
1'-3"
SHARPS CONTAINER
(VC)
C8
AE601
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
1'-6"
HOOK (CC)
HOOK (CC)
CG1
OPEN
BEYOND
6" 3'-0" 2'-6"
GRAB BAR, 36" VERT.
(CC)
GRAB BAR, 36" VERT.
(CC)
8"
GRAB BAR, 36" VERT.
(CC)
OPEN
BEYOND
CG1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:4
P M
DPD JAP
AE251
INTERIOR ELEVATIONS
DWG. 39 OF 147
1/2" = 1'-0"AE251
F9 EXAM - NORTH
1/2" = 1'-0"AE251
F7 EXAM - EAST
1/2" = 1'-0"AE251
F5 EXAM - SOUTH
1/2" = 1'-0"AE251
F3 EXAM - WEST
1/2" = 1'-0"AE251
F1 TEAMLET WORKSTATIONS - SOUTH
1/2" = 1'-0"AE251
E8 TEAMLET WORKSTATIONS - EAST
1/2" = 1'-0"AE251
E7 REFRESHMENT ALCOVE - WEST
1/2" = 1'-0"AE251
E5 SOILED HOLDING - WEST
1/2" = 1'-0"AE251
E3 SOILED HOLDING - EAST
1/2" = 1'-0"AE251
E2 SOILED HOLDING - SOUTH
1/2" = 1'-0"AE251
C7 HOUSEKEEPING CLOSET - WEST
1/2" = 1'-0"AE251
C8 HOUSEKEEPING CLOSET - NORTH
1/2" = 1'-0"AE251
C5 TYPICAL TOILET - EAST
1/2" = 1'-0"AE251
C4 TYPICAL TOILET - SOUTH
1/2" = 1'-0"AE251
C2 TYPICAL TOILET - WEST
1/2" = 1'-0"AE251
C1 TYPICAL TOILET - NORTH
1/2" = 1'-0"AE251
B7 TRIAGE - WEST
1/2" = 1'-0"AE251
B6 TRIAGE - NORTH
1/2" = 1'-0"AE251
B4 H/W SCALE ALCOVE - NORTH
1/2" = 1'-0"AE251
B3 H/W SCALE ALCOVE - EAST
1/2" = 1'-0"AE251
B1 H/W SCALE ALCOVE - SOUTH
0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6"
0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6"
0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6"
INTERIOR ELEVATION NOTES
1. REFER TO TYPICAL MOUNTING HEIGHTS SHEET G003
2. REFER TO ROOM FINISH SCHEDULE FOR ADDITIONAL FINISH
INFORMATION
3. FOR CASEWORK LEGEND, SEE SHEET AE701
4. EQUIPMENT DESIGNATION AS FOLLOWS (U.N.O.):
VV - VA PROVIDED / VA INSTALLED
VC - VA PROVIDED / CONTRACTOR INSTALLED
CC - CONTRACTOR PROVIDED / CONTRACTOR INSTALLED
HOOK (CC)
HOOK (CC)
HOOK (CC)
HOOK (CC)
MIRROR, 18x60 (CC)
1'-6" EQ EQ 1'-6"
1'-9"
PAPER TOWEL
DISPENSER (VC)
SOAP DISPENSER (VC)
HOOK (CC)
HOOK (CC)
F
8" 1'-8"
1'-3"
PL1
HAND SANITIZER (VC)
1'-2"
1'-5" 1'-6" 8"
SOAP DISPENSER (VC)
PAPER TOWEL
DISPENSER (VC)
SHARPS CONTAINER
(VC)
HOOK (CC)
HOOK (CC)
F
1'-6"
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
C8
AE601
PL1
1'-9"
3'-2"
GLOVES DISPENSER
(VC)
EQ EQ
HAND SANITIZER (VC)
MIRROR, 18x60 (CC)
BLOCKING AT CUBICLE
TRACK ENDS, TYP. SEE
C8
AE601
3'-10"
EQ 4'-0" EQ
SLIDESLIDE
EQ4'-0"EQ
SLIDESLIDE
SA
CB KS
1'-4" 3'-9"
G
WM
PL2
PL2
1'-4"3'-9"
CB
SA
G
SA SA
KS
WM
CB CB
F2
AE701
F2
AE701
AE701
E2
2'-1"
4'-0"
G
KS
CB
SA
WM
PL2
4'-2"
F
F
24243034
PL1
PL1
PL1
PL2
2'-1"
SA
CB KS
4'-0"
G
WM
PL2
4'-2"
8"
GRAB BAR, 36" VERT.
(CC)
OPEN
BEYOND
CG1
EQ EQ
HOOK (CC)
HOOK (CC)
1'-6"
MIRROR, 24x36 (CC)
3-PIECE GRAB BAR
(CC)
TOILET SEAT COVER
DISPENSER (CC)
PAPER TOWEL
DISPENSER (VC)
1'-10"1'-4"
FIXTURE WALL, SEE
INTERIOR SHEETS
7"8"1'-4"
PAPER TOWEL
DISPENSER (VC)
SOAP DISPENSER (VC)
2'-6"
KS
SA
PL1PL1 SS1
3034 3034 3034 3034
3024 3024 3024
F3
AE701
SINK BY
PLUMBING TRADE
A L
IG
N 1'-6"
HOOK (CC)
HOOK (CC)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:0
P M
DPD JAP
AE252
INTERIOR ELEVATIONS
DWG. 40 OF 147
1/2" = 1'-0"AE252
F8 MH OFFICE - WEST
1/2" = 1'-0"AE252
F7 CLINICAL PHARM - EAST
1/2" = 1'-0"AE252
F5 CLINICAL PHARM - EAST
1/2" = 1'-0"AE252
F3 TELEHEALTH EXAM - NORTH
1/2" = 1'-0"AE252
F1 TELEHEALTH EXAM - EAST
1/2" = 1'-0"AE252
E9 TELEHEALTH EXAM - SOUTH
1/2" = 1'-0"AE252
E7 TELEHEALTH EXAM - WEST
1/2" = 1'-0"AE252
E6 TELEHEALTH WORKROOM - NORTH1
1/2" = 1'-0"AE252
E3 TELEHEALTH WORKROOM - EAST
1/2" = 1'-0"AE252
E1 TELEHEALTH WORKROOM - SOUTH
1/2" = 1'-0"AE252
C7 TELEHEALTH WORKROOM - WEST
1/2" = 1'-0"AE252
C6 H/W SCALE ALCOVE - SOUTH
1/2" = 1'-0"AE252
C5 H/W SCALE ALCOVE - WEST
1/2" = 1'-0"AE252
C3 PATIENT TOILET - SOUTH
1/2" = 1'-0"AE252
C1 HBPC WORKROOM - NORTH
1/2" = 1'-0"AE252
B7 TYPICAL OFFICE - EAST
0 1' 2' 3'6"
0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0C.0A.3
BASEMENT
1137' - 0"
PARAPET
1178' - 11 1/2"
EGRESS
LANDING
1142' - 0"
OFFICE
(NURSE
MANAGER)
RECEPTION
OFFICE
(TELEHEALTH)
CORRIDOR
ELECTRICAL
ROOM
ELECTRICAL
ROOM
CORRIDOR
CORRIDOR
STAIR
ST-1
PIPE
BASEMENT
B001
B.4A.9
AE351
F9
3 1/2" SPRAY INSULATION AT
FIRST FLOOR DECK, APPLY
AFTER FIRE PROOFING
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
2.7 0.0
BASEMENT
1137' - 0"
1.5
PARAPET
1178' - 11 1/2"
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
0.5
EGRESS
LANDING
1142' - 0"
EXISTING -
PENTHOUSE
ROOF DECK
1186' - 0"
STAIR
ST-1
CORRIDOR
HBPC
WORKROOM
TELEHEALTH
EXAM
HALLWAY
TELEHEALTH
EXAM
EXAM
CORRIDOR
TEAMLET
WORKSTATIONS
MEDICAL
EQUIPMENT
STORAGE
PIPE
BASEMENT
B001
23 1.3 0.8 0.7
AE351
F5
AE352
F3
AE352
F3
12 2
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0C.0
BASEMENT
1137' - 0"
B.0
PARAPET
1178' - 11 1/2"
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
EGRESS
LANDING
1142' - 0"
EXISTING -
PENTHOUSE
ROOF DECK
1186' - 0"
PIPE
BASEMENT
B001
CORRIDOR
CONNECTION
SUB-WAIT
HALLWAY
PATIENT
TOILET
TELEHEALTH
EXAM
TELEHEALTH
EXAM
TELEHEALTH
EXAM
A B.4
AE352
F8 ------------
AE351
F5
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
2.7 0.0
BASEMENT
1137' - 0"
1.5
PARAPET
1178' - 11 1/2"
EXISTING -
PENTHOUSE
PARAPET
1189' - 8 3/4"
0.5
EGRESS
LANDING
1142' - 0"
EXISTING -
PENTHOUSE
ROOF DECK
1186' - 0"
CORRIDOR
HBPC
WORKROOM
HALLWAY
TELEHEALTH
WORKROOM
CORRIDOR
EXAM
EXAM
EXAM
EXAM
CLEAN
UTILITY
SOILED
HOLDING
CORRIDOR
CONFERENCE
ROOM
PIPE
BASEMENT
B001
3 1.3 0.8 0.7
OFFICE
(TELEHEALTH)
OFFICE
(HBPC)
SUB-WAIT
AE351
F5
AE352
F3
AE352
F3
AE351
F7
12 2
PATIENT
TOILET
NEW WORK KEYED NOTES:
1 PROVIDE (2) HOUR FIRE PROTECTION ON ROOF/FLOOR
ASSEMBLY IN FULL COLUMN BAY, FULL DEPTH OF PENTHOUSE
2 PROVIDE (1) HOUR ROOF ASSEMBLY
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:1
P M
DPD JAP
AE301
BUILDING SECTIONS
DWG. 41 OF 147
1/8" = 1'-0"AE301
C2 BUILDING SECTION 1
1/8" = 1'-0"AE301
C6 BUILDING SECTION 2
1/8" = 1'-0"AE301
F2 BUILDING SECTION 3
1/8" = 1'-0"AE301
F6 BUILDING SECTION 4
4'0 8' 12'2' 4'0 8' 12'2'
4'0 8' 12'2'4'0 8' 12'2'
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
2.7
BASEMENT
1137' - 0"
EGRESS
LANDING
1142' - 0"
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
BLAST RATED
CURTAIN WALL
SYSTEM
MEMBRANE ROOFING ON
TAPERED INSULATION
PRECAST ARCHITECTURAL
CONCRETE TO MATCH
EXISTING
FOUNDATION WALL -
SEE STRUCTURAL
SHEET
WATERPROOFING
/4
M A
T C
H E
X
IS
T
IN
G
/4
V
IF
M A
T C
H E
X
IS
T
IN
G
V
IF
/8
/4
/8
/2
/2
2 HOUR FIRE RATED
FLOOR ASSEMBLY PER
U.L. NO. CW-S-0002
2" PERIMETER
INSULATION
AE505
C5
AE505
B5
AE505
F5
SPANDREL GLASS
VISION GLASS
VISION GLASS
SPANDREL GLASS
SPANDREL GLASS
3" POLYISOCYANURATE
INSULATION
5/8" GYP BOARD OVER
6" METAL STUDS
PAN SHALL BE INSTALLED
FLUSH WITH BACK OF MULLION
AND EXTEND TO WITHIN 1/2"
OF TERMINATION OF BACK
MULLION TUBE AT GLASS
FACE. SEAL TO CURTAINWALL
MULLION WITH SILICONE
SEALANT AND NO. 8 SCREWS
8" O.C. MAX. COVER EXPOSED
FLANGE WITH 1"X4" WIDE
CURTAINWALL INSULATION,
TYP.
FILL BOX PAN TO WITHIN 1"
OF PAN DEPTH WITH
CURTAINWALL INSULATION.
INSULATION IMPALING PINS
SHALL BE WELDED IN PLACE
NOT LESS THAN (1) PER
SQUARE FOOT, TYP.
20 GAUGE GALVANIZED FULLY
WELDED STEEL BOX PAN BY
CURTAINWALL SUPPLIER
(SMOKE AND WATER TIGHT),
TYP.
SHADE POCKET BY
CEILING MANUFACTURER
5/8" GYPSUM BOARD
OVER 2" PERIMETER
INSULATION BETWEEN
Z-CHANNELS 24" O.C. -
8'-0" TOTAL HEIGHT
AE505
F2
AE505
F2
AE505
E2
SHADE POCKET BY
CEILING MANUFACTURER
AE505
E2
DRAINAGE BY
PLUMBING TRADE
(1) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0
BASEMENT
1137' - 0"
PARAPET
1178' - 11 1/2"
EGRESS
LANDING
1142' - 0"
FACE BRICK AND
COURSING TO
MATCH EXISTING
AIRSPACE
3" POLYISOCYANURATE
INSULATION
AIR AND VAPOR BARRIER
8" BLAST RATED CMU WITH
INSULATED CAVITIES
(WHERE UNGROUTED)
PRECAST ARCHITECTURAL
CONCRETE TO MATCH
EXISTING
ALUMINUM PARAPET,
MATCH EXISTING FINISH
FOUNDATION WALL -
SEE STRUCTURAL
GRADE
SHEET
WATERPROOFING
MEMBRANE ROOFING ON
TAPERED INSULATION
PLYWOOD ON
ROOFING INSULATION
2'-0"
2" PERIMETER
INSULATION
AE502
F9
AE502
E9
AE502
C9
/4
/4
3 1/2" SPRAY INSULATION
AT FIRST FLOOR DECK
DRAINAGE BY
PLUMBING TRADE
DOVETAIL INSERTS
AT 16" O.C.
(1) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
ANY VOIDS BETWEEN
SLAB AND BLOCK MUST BE
FIRESTOPPED, TYPICAL
WALL TIES AT 16" O.C.,
TYPICAL
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
0.0
BASEMENT
1137' - 0"
PARAPET
1178' - 11 1/2"
FACE BRICK AND
COURSING TO
MATCH EXISTING
AIRSPACE
3" POLYISOCYANURATE
INSULATION
AIR AND VAPOR BARRIER
8" BLAST RATED CMU WITH
INSULATED CAVITIES
(WHERE UNGROUTED)
5/8" GYPSUM BOARD
OVER 2-1/2" METAL STUDS
PRECAST ARCHITECTURAL
CONCRETE TO MATCH
EXISTING
ALUMINUM PARAPET,
MATCH EXISTING FINISH
FOUNDATION WALL -
SEE STRUCTURAL
GRADE
SHEET
WATERPROOFING
BLAST RATED
WINDOW SYSTEM
BLAST RATED
WINDOW SYSTEM
LEDGE HEIGHT VARIES -
SEE STRUCTURAL
/4
/4
/4
M A
T C
H E
X
IS
T
IN
G
/4
V
IF
M A
T C
H E
X
IS
T
IN
G
V
IF
/8
M A
T C
H E
X
IS
T
IN
G
/4
M A
T C
H E
X
IS
T
IN
G
/8
2'-0"
5/8" GYPSUM BOARD
OVER 2-1/2" METAL STUDS
2" PERIMETER
INSULATION
AE502
F9
AE502
E9
AE502
C9
MEMBRANE ROOFING ON
TAPERED INSULATION
PLYWOOD ON
ROOFING INSULATION
3 1/2" SPRAY INSULATION
AT FIRST FLOOR DECK
DRAINAGE BY
PLUMBING TRADE
DOVETAIL INSERTS
AT 16" O.C.
(1) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
ANY VOIDS BETWEEN
SLAB AND BLOCK MUST BE
FIRESTOPPED, TYPICAL
FIRST FLOOR
1148' - 0"
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
A.3
PARAPET
1178' - 11 1/2"
FACE BRICK AND
COURSING TO
MATCH EXISTING
AIRSPACE
3" POLYISOCYANURATE
INSULATION
AIR AND VAPOR BARRIER
8" BLAST RATED CMU WITH
INSULATED CAVITIES
(WHERE UNGROUTED)
EXISTING
FOUNDATION
WALL
EXISTING STRUCTURE
TO REMAIN. PROTECT
EXISTING STRUCTURE
DURING CONSTRUCTION
REPLACE ALUMINUM
PARAPET CAP TO
MATCH EXISTING
FOUNDATION WALL -
SEE STRUCTURAL
AE502
D8
AE502
C9
PRECAST ARCHITECTURAL
CONCRETE TO MATCH
EXISTING
ALUMINUM PARAPET,
MATCH EXISTING FINISH
MEMBRANE ROOFING ON
TAPERED INSULATION
PLYWOOD ON
ROOFING INSULATION
2'-0"
(1) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
(2) HOUR SPRAY
FIREPROOFING ON BEAMS
ANY VOIDS BETWEEN
SLAB AND BLOCK MUST BE
FIRESTOPPED, TYPICAL
CLSM FILL - SEE
SPECIFICATIONS
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMP
321 4 5 6 7 8 9 10
EXPAND PRIMARY CARE
OSCAR G. JOHNSON VA MEDICAL CENTER
325 H STREET,
IRON MOUNTAIN, MI 49801
ARCHITECT/ENGINEER
310 Pine Street | Green Bay, WI 54301 920-432-4865 | www.bernersschober.com
FULLY SPRINKLERED
Comm. Number: 5700.16
DECEMBER 4, 2020
585-336
U.S. Department of Veterans Affairs
100% DESIGN SUBMITTAL
Revisions: Date:
CONSULTANT
Architecture | Planning | Interior Design
2224 S. Michigan Ave. | Suite 1400 Chicago, Illinois 60604-2595
(312)-554-1400
65% SUBMITTAL 04/28/2020
project number: 1180742
95% SUBMITTAL 07/24/2020
100% SUBMITTAL 12/04/2020
B
IM
/V
A G
L H
S E x p a n d P ri m a ry
C a re /V
A A
R C
H .r v t
/1 /2
:2
:2
P M
DPD JAP
AE351
WALL SECTIONS
DWG. 42 OF 147
1/2" = 1'-0"AE351
F3 WALL SECTION AT WEST CURTAINWALL
1/2" = 1'-0"AE351
F5 TYPICAL WALL SECTION
1/2" = 1'-0"AE351
F7 WALL SECTION AT RIBBON WINDOWS
1/2" = 1'-0"AE351
F9 WALL SECTION AT AMBULANCE GARAGE
0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6" 0 1' 2' 3'6"
CURTAINWALL ANCHORAGE TO STRUCTURE TO
BE DESIGNED BY MANUFACTURER TO MEET
BLAST RESISTANCE REQUIREMENTS.
ANCHORAGE MUST NOT PENETRATE BACKPAN.
SECOND FLOOR
1161' - 0"
ROOF DECK
1175' - 0"
D.0
BASEMENT
1137' - 0"
EGRESS
LANDING
1142' - 0"
5/8" GYP BOARD OVER
2-1/2" METAL STUDS
BLAST RATED
CURTAIN WALL
SYSTEM
PRECAST ARCHITECTURAL
CONCRETE TO MATCH
EXISTING
/2
/1
/4
/1
/8
/4
/8
/2
/2
/4
2 HOUR FIRE RATED
FLOOR ASSEMBLY PER
U.L. NO. CW-S-0002
AE505
C5
AE505
C5
SIM.
AE505
F4
SPANDREL GLASS
VISION GLASS
VISION GLASS
SPANDREL GLASS
5/8" GYP BOARD OVER
6" METAL STUDS
SPANDREL GLASS
CONCRETE CURB -
SEE STRUCTURAL
PAN SHALL BE INSTALLED
FLUSH WITH BACK OF MULLION
AND EXTEND TO WITHIN 1/2"
OF TERMINATION OF BACK
MULLION TUBE AT GLASS
FACE. SEAL TO CURTAINWALL
MULLION WITH SILICONE
SEALANT AND NO. 8 SCREWS
8" O.C. MAX. COVER EXPOSED
FLANGE WITH 1"X4" WIDE
CURTAINWALL INSULATION,
TYP.
FILL BOX PAN TO WITHIN 1"
OF PAN DEPTH WITH
CURTAINWALL INSULATION.
INSULATION IMPALING PINS
SHALL BE WELDED IN…