Attachment 5 - Drawings 100 Percent - Mathers VAMC - Part 2 - Final.pdf
PDF 11 MB Posted
- Attached to
- Y1DZ--Facility for Mental Health Primary Care Modalities - Minor Construction - Mather VAMC
- Solicitation number
- 36C77624B0005
About this file
This file is an attachment to a federal solicitation for construction services. The Department of Veterans Affairs Technology Acquisition Center Austin is seeking proposals to construct a facility for mental health and primary care services at the Mathers Veterans Affairs Medical Center. The attachment includes final construction drawings for the project. Offerors should submit responses to solicitation number 36C77624B0005 by the unspecified deadline. The award is for minor construction work to expand modalities for treating veterans' mental health and primary healthcare needs at the named VA medical center location.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FINISHED FLOOR
CEILING AS SCHEDULED
ADDITIONAL
LAYER OF GYP BOARD
AT HORIZONTAL IF
WALL IS 1 HR RATED
MEP OR OTHER NON-
SPECIFIC OBSTRUCTION
1" GYPSUM LINER
PANEL
STRUCTURE
ABOVE
CONT 2" X 2" X 20 GA ANGLE
3 5/8" METAL
STUD BRACING
AT 48" OC
THERMAL
INSULATION
VAPOR
RETARDER TAPE
GYP BOARD
FIRE STOP
SEALANT
VAPOR
RETARDER
ONE PIECE
BARRIER BOX
SEALANT BETWEEN
ELECTRICAL OUTLET
BOX AND GYP BOARD
NOTES:
1. CUT, FOLD, AND TAPE THE FLAPS
OF THE VAPOR RETARDER TO THE
INSIDE OF THE BARRIER BOX PRIOR
TO INSTALLING THE ELECTRICAL
OUTLET BOX.
2. FILL THE SPACE BETWEEN THE
ELECTRICAL OUTLET BOX AND THE
BARRIER BOX WITH INSULATION.
3. REINFORCE AND SEAL EDGES OF
THE BARRIER BOX TO THE VAPOR
RETARDER.
GYP BOARD
FIRE STOP
SEALANT
SEALANT BETWEEN
ELECTRICAL OUTLET
BOX AND GYP BOARD
NOTES:
1. ELECTRICAL OUTLETS ON OPPOSITE SIDES
OF A SOUND-RATED WALL ARE TO BE SPACED
TO PROVIDE A MINIMUM OF ONE STUD
BETWEEN THE BOXES.
2. THE PUTTY PAD IS TO COMPLETELY SEAL
ALL SIDES OF EACH OUTLET BOX.
3. WHERE PARTITIONS ARE SCHEDULED TO
BE SOUND RATED PROVIDE ACOUSTICAL
PUTTY PAD AT ALL OUTLET LOCATIONS.
ACOUSTICAL
INSULATION
PUTTY PAD
NOTES:
PUTTY PAD MUST BE FIRE RATED IN FIRE RATED PARTITIONS.
STL STUDS
EXTERIOR GYP
SHEATHING OR BACK
OR PRECAST OR
CONCRETE EXTERIOR
WALL
EXTERIOR WALL
MATERIAL
TAPE AND JOINT
FIRE STOP SEALANT AND
BACKER ROD, TYP
SEAL ALL WALL
PENETRATIONS
PARTITION TYPES
REF FLOOR PLANS FOR
NOTE: RATED WALL MUST EXTEND TO BACK OF EXTERIOR SHEATHING
BACK OF PRECAST OR CONCRETE WALL TO COMPLY WITH CODE
REQUIREMENT.
F.O.G.
MULLION
AND WALL
EOS, BELOW
X
SHOP MANUFACTURED
20 GA STEEL CLOSURE
TRIM FINISH TO MATCH
ALUMINUM GLAZING
SYSTEM
ALUMINUM GLASS
SYSTEM
MINERAL WOOL
FULL
THICKNESS
ALUMINUM GLAZING
SYSTEM SNAP CAP OR
BUTT GLAZED SYSTEM
2 1/2"
MINERAL WOOL FULL
THICKNESS
SILL EXTENSION
BELOW
FIRESTOP SEALANT
FLEXIBLE FIRESTOP
SEAL
2 1/2"
5"
FOR PARTITION TYPE
REF FLOOR PLAN
GLAZING BLOCK
3" W X 3" L X 3" D X 1/8" ALUM
CLIP AT TOP AND BOTTOM
OF ALUM MULLION COVER.
FASTEN TO TOP AND
BOTTOM OF SLAB. VERTICAL
LEG OF TOP CLIP TO BE
SLOTTED.B
E J
O B
S P
E C
IF
IC
A D
JU
S
T D
IM
T
O
ONE HOUR
WALL
/8
2" X 2" X 20 GA
CONT METAL
ANGLE EACH SIDE
M
IN
”2" - 4"
RATED PARTITION
AS SCHEDULED ON
2 1/2" STUDS AND
RUNNERS
FOR BEAMS AND
JOISTS WITH A
MAXIMUM DEPTH
OF 1'-6"
RATED PARTITION
CUT GYP BD TO
CONFORM TO DECK
PROFILE SEAL PER
RATED ASSEMBLY
REQUIREMENT
1' - 0"
FIRE
EXTINGUISHER
CABINET
GYP BOARD
NOTE:
VERIFY CABINET
OPENING SIZE
WITH APPLICABLE
PRODUCT
FIRE
EXTINGUISHER
CABINET
GYP BOARD
NOTE:
VERIFY CABINET
OPENING SIZE
WITH APPLICABLE
PRODUCT
F.O.G.
EOS, BELOW
SHOP MANUFACTURED
20 GA STEEL CLOSURE
TRIM FINISH TO MATCH
ALUMINUM GLAZING
SYSTEM
ALUMINUM GLASS
SYSTEM
MINERAL WOOL
FULL
THICKNESS
MINERAL WOOL FULL
THICKNESS
SILL EXTENSION
BELOW
FIRESTOP SEALANT
FLEXIBLE FIRESTOP
SEAL
MATCH WALL THICKNESS
+/- 5"
FOR PARTITION TYPE
REF FLOOR PLAN
GLAZING BLOCK
3" W X 3" L X 3" D X 1/8" ALUM
CLIP AT TOP AND BOTTOM
OF ALUM MULLION COVER.
FASTEN TO TOP AND
BOTTOM OF SLAB. VERTICAL
LEG OF TOP CLIP TO BE
SLOTTED.B
E J
O B
S P
E C
IF
IC
A D
JU
S
T D
IM
T
O
ONE HOUR
WALL
/8
PARTITION
/8
CONT 2" WIDE
NEOPRENE
FILLER
1/8" EACH SIDE
CASING BEAD
CEILING GRID
SUSPENSION
SYSTEM
MAX
1/2"
1HR FIRE RATED
WHI-495-0824A
MINERAL WOOL
PARTITION
CONTROL JOINT
3"
3"
MAX
1/2"
2HR FIRE RATED
WHI-495-0824
MINERAL WOOL
PARTITION
CONTROL JOINT
MAX
1/2"
5/8"
24'-0"
MAX
24'-0"
MAX
1HR FIRE RATED
WHI-651-0318.1
2 LAYERS 5/8"
GYP BD
PARTITION
CONTROL JOINT
PARTITION
SOUND
ATTENUATION
BLANKET
COMPRESSED TO
FILL OPENING AT
SOUND RATED
PARTITION
L-BEAD
ACOUSTICAL
SEALANT AND
BACKER ROD
LINE OF
PARTITION
1/4”
ACOUSTICAL
SEALANT
"LC" - BEAD
PARTITION
24'-0" - 30'-0"
MAX
CONTROL JOINT
GYP BOARD
SUSPENDED
CEILING SYSTEM
24'-0" - 30'-0"
MAX
DOOR LOCATION
JAMB STUDS AS
REQUIRED
HOLLOW METAL
FRAME
LOWER PRIORITY
PARTITION
HIGHER PRIORITY
PARTITION
GYP SHEATHING
SECOND LAYER
OF GYP BD
WHERE
SCHEDULED
RATED PARTITION
AS INDICATED ON
PLAN
1 1/2" = 1'-0"04
SECTION THROUGH
PARTITION INTERRUPTED
BY NON-SPECIFIC OBSTRUCTION
1 1/2" = 1'-0"08
ONE PIECE BARRIER
BOX IN EXTERIOR WALL/
INTERIOR SIDE VAPOR RETARDER
1 1/2" = 1'-0"09
ACOUSTICAL PUTTY PAD
SOUND ATTENUATION
IN INTERIOR PARTITION
3" = 1'-0"07
PLAN DETAIL AT FIRE
AND/OR FIRE/SMOKE
PARTITION AT EXTERIOR WALL
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUSAESUS
A3.03
GYP BD DETAILS 01
3" = 1'-0"06
PLAN DETAIL AT SOUND BARRIER OR RATED
PARTITION / MULLION TRIM CAP
1 1/2" = 1'-0"03
SECTION AT RATED
PARTITION ADJACENT TO BEAM
1 1/2" = 1'-0"02
FRAMING AT 1-HR WALL FIRE
EXTINGUISHER CABINET AT RATED WALL
1 1/2" = 1'-0"01
FRAMING AT 2-HR WALL FIRE
EXTINGUISHER CABINET AT RATED WALL
3" = 1'-0"05
PLAN DETAIL AT SOUND BARRIER OR RATED
PARTITION AT GLAZING CAP
3" = 1'-0"13
CONTROL JOINT AT
PARTITION ATTACHMENT
TO CEILING GRID
3" = 1'-0"18
CONTROL JOINT AT
FIRE-RATED PARTITION
3" = 1'-0"17
CONTROL JOINT AT
FIRE-RATED PARTITION
3" = 1'-0"12
CONTROL JOINT AT
FIRE-RATED PARTITION
3" = 1'-0"16
CONTROL JOINT AT
PARTITION INTERSECTION
CHANGE IN CONSTRUCTION
3" = 1'-0"11
CONTROL JOINT AT PARTITION
NON-EXPOSED EDGE
3" = 1'-0"15
CONTROL JOINT FOR
GYPSUM BOARD CEILING
3" = 1'-0"10
INTERSECTION AT CROSS
CORRIDOR DOOR ONE
HOUR RATED PARTITION
3" = 1'-0"14
INTERSECTION AT RATED
PARTITION AT EXTERIOR WALL
CONTROL JOINT DETAILS
08.18.23
TOILET ACCESSORY MOUNTING DIAGRAM SCALE: 1/4" = 1'-0"
NOTE:
1. ACCESSORIES LISTED MAY
HAVE GAPS IN ALPHABETICAL
LISTING.
2. ACCESSORIES CAN APPEAR
ON FLOOR PLANS OR INTERIOR
ELEVATIONS.
3. REFER TO EQUIPMENT LIST
FOR ALL JSN NUMBERS AND
INFORMATION REGARDING WHO
SHALL PROVIDE AND INSTALL
EACH ITEM.
FINISH FLOOR
TOILET
ACCESSORY
TYPE
MOUNTING
DETAIL - REFER
TO SHEET A3.02
DRAWING
DESIGNATION
CL
P O
IN
T
T O
D
IS
P E
N S
IN
G
PAPER
TOWEL
DISPENSER
A
FINISH FACE
OF WET WALL
TOILET TISSUE
DISPENSER
A
B9 TWIN
JUMBO -
ROLL
T O
C L
ACCESSIBLE
TOILET STALL
GRAB BAR
FINISH FLOOR
TOILET
ACCESSORY
TYPE
MOUNTING
DETAIL - REFER
TO SHEET A3.02
DRAWING
DESIGNATION
SOAP
DISPENSER
& HAND
SANITIZER
A
A5075 A5077
OWNER
FURNISHED,
SURFACE
MOUNTED
TOILET
SEAT
COVER
DISPENSER
A
K1 OWNER
FURNISHED,
SURFACE
MOUNTED
STAINLESS
STEEL
FRAMED
MIRROR
B
R1 WITHOUT
SHELF
SURFACE
MOUNTED
GARMENT
HOOK
A
V1 1 1 /2"
SINGLE
SURFACE
MOUNTED
M A
X
GLOVE
DISPENSER
SURFACE
MOUNTED
"SEE PLAN
T O
S P
O U
T
D
IS
P T
O S
L O
T
T O
T O
P O
F F
R A
M E
42 X 54 -
NON-SLIP FINISH
E16
C
D AT BARIATRIC
CONDITIONS ONLY
FIXTURE AND PARTITION MOUNTING DIAGRAM
A5082
OWNER
FURNISHED
SURFACE
MOUNTED
B O
T T
O M
M
IN
T O
INSULATE
ALL
PIPING
AT HC
MIRROR
NON-ACCESSIBLE
WALL MOUNTED
LAVATORY, L4
URINAL EWC
DRINKING
FOUNTAIN
WALL
MOUNTED
TOILET
2 1/2"
SERVICE
SINK
PARTITION
TYPE
MOUNTING -
REF A3.03
C
URINAL
PARTITION
FINISH
FLOOR
M A
X T
O
R
IM
A
C C
E S
S
IB
L E
F L U
S H
H A
N D
L E
M
A X
T O
M
IN
M
IN
6" MAX 8" MIN
A C
C E
S S
O R
Y
M A
X T
O S
P O
U T
1 1/4"
18 1/2”
O F
B O
W L
T O
T O
P
25” 24 1/2”
/4
T O
H A
N D
L E
M A
X T
O F
L U
S H 2
PARTITION
TYPE
MOUNTING -
REF A3.03
C
SUPPORT
BRACING
PARTITION
TYPE
MOUNTING -
REF A3.03
C
CEILING
MOUNTED TOILET
PARTITION
FLOOR AND CEILING
ANCHORED TOILET
PARTITION
CLEAR
3' - 0" 2' - 0"
MOP SINK FAUCET
SUPPORT BRACKET
PLAN DESIGNATION MS
W
IT
H F
A U
C E
T C
O O
R D
IN
A
T E
TYPE
MOUNTING -
REF A3.03
C
7"-9"
M
IN
” T O
C L
T O
T O
P
M
A X
M
IN
/2
M
IN
42' MAX
M A
X
T O
C L
T O
T O
P
M
A X
M
IN
/2
M
IN
ALLOWABLE
MOUNTING
LOCATIONS
ACCESSIBLE
MOUNTING DIAGRAM
FOR TOILET PAPER
DISPENSER
ACCESSIBLE MOUNTING
DIAGRAM FOR OTHER
APPROVED TOILET
ACCESSORIES PER ADA
604.3.2
MISCELLANEOUS SPECIALTIES AND EQUIPMENT SCALE: 1/4" = 1' - 0"
MOUNTING DETAIL -
REFER TO SHEET A3.02
FINISH FLOOR
DESCRIPTION
A
WHITE BOARD
B
SEMI RECESSED FIRE
EXTINGUISHER CABINET,
CONTRACTOR PROVIDED
AND INSTALLED
FEC
H E
IG
H
T
M A
T C
H L
O C
K S
E T
WALL MOUNTED
DOOR STOP
A
DEVICE MOUNTING DIAGRAM
FINISH FLOOR
8" 6" 6"6" 6" 6"
MAX)
8” (5' - 0”
O F
D E
V
IC
E
T O
T O
P
O F
D E
V
IC
E
T O
T O
P
O F
D E
V
IC
E
T O
C E
N T
E R
O F
D E
V
IC
E
T O
T O
P
CARD READER
OUTLET
TEMPERATURE
SENSOR
S W
IT
C
H
MOISTURE SENSOR
HUMIDITY SENSOR
C02 SENSOR
EXIT LIGHT OVER DOOR
OPTIONAL VERTICAL LOCATION
FOR NON-OPERABLE DEVICE IF
HORIZONTAL POSITION IS NOT
POSSIBLE
STROBE
FIREFIGHTERS
TELEPHONE
(REF PLAN FOR LOCATION)
OUTLET (REF PLAN FOR
LOCATION)
EXIT LIGHT (REF PLAN FOR
LOCATION)
EQ EQ
EQ EQ
A L
IG
N
A N
Y
H
IG
H A
N D
L
W
F
IX
T
U R
E S
GENERAL NOTES FOR DEVICE MOUNTING
1. REFER TO EQUIPMENT LIST JSN NUMBER FOR ADDITIONAL INFORMATION FOR FURNITURE, MEDICAL
EQUIPMENT AND TOILET ACCESSORIES.
2. CONSULT VA FOR FINAL FOR MOUNTING LOCATIONS OF CARD READERS AND OTHER DEVICES.
3. DIMENSIONS SHOWN ARE TO CENTERLINE OR TO EDGE OF FACEPLATE (REFER TO TYPICAL DEVICE
ELEVATION.)
4. DEVICES ABOVE COUNTERS SHALL BE MOUNTED IN THE HORIZONTAL POSITION. OTHER DEVICES
SHALL BE VERTICAL UNLESS OTHERWISED NOTED.
5. WHERE THERE IS INSUFFICIENT SPACE TO MOUNT ALL DEVICES, DEVICES MAY BE LOCATED
VERTICALLY ALIGNED.
6. WHERE MULTIPLE SWITCHES ARE LOCATED ADJACENT TO EACH OTHER, PROVIDE A SINGLE COVER
PLATE.
7. ALL DEVICE COVER PLATE COLORS PER SPECIFICATIONS.
EXIT SIGN (REQ FOR R-1
OCCUPANCIES, REF FLOOR
PLAN FOR LOCATIONS)
MEDICAL EQUIPMENT MOUNTING DIAGRAM SCALE: 1/4" = 1' - 0"
FINISH FLOOR
MOUNTING DETAIL -
REFER TO SHEET
A3.02
DRAWING
DESIGNATION
F3200
CLOCK
A
A5108
SHARPS
CONTAINER
M0515
TV /
MONITOR &
BRACKET
B
FLAT SCREEN TV
/ MONITOR
SHOWN DASHED
TV SUPPORT
BRACKET
POWER/DATA
OUTLETS REF DETAIL
A3.24/01 FOR
BACKING AND
OUTLET
INFORMATION
U N
O O
N E
L E
V A
T
IO
N S
SUPPORT
BRACING
A
STANDARD LAYOUTS - CALIFORNIA SCALE: 1/4" = 1' - 0"
PLAN DESIGNATION S2
V1
S2B9
S4
G3
B9
O F
W E
T W
A L
L
T
O F
IN
IS
H
INSIDE FACE
3' - 0" INSIDE
FACE TO
STANDARD URINAL
PLAN DESIGNATION U1
U1
INSIDE FACE
3' - 0" INSIDE
FACE TO
STANDARD COMPARTMENT
PLAN DESIGNATION S4
FOUNTAIN/COOLER
PLAN DESIGNATION EWC3
1' - 6" 1' - 6"
M A
X
EWC3
30" X 48"
CLEAR FLOOR
SPACE
STANDARD
ACCESSIBLE LAVATORY
PLAN DESIGNATION L1
S E
C T
1' - 6" 2' - 6" 1' - 6"
R1
L1
J1
A1
30" X 48" CLEAR
FLOOR SPACE
LAV
SUPPORT
C L R
O P
N G
M
IN
M A
X
EQ EQ
EQ EQ
FIN
1' - 6”
MAX TO
5' - 1" FIN TO FIN
M A
X
A C
C E
S S
IB
L E
M A
X A
T
3' - 6"
V1
E16
NOTES:
1. COORDINATE LAVATORY SUPPORTS WITH BOWL
LOCATIONS.
2. LOCATE FLUSH ACTIVATION ON WIDE SIDE AT ALL
TOILETS - LOCATE FLUSH VALVE BENEATH ADJACENT
GRAB BARS.
3. REFER TO EQUIPMENT LIST JSN NUMBERS FOR
ADDITIONAL INFORMATION
4. ALL TOILET PARTITIONS TO BE CEILING MOUNTED,
CONFIRM WITH COR IF ADDITIONAL FLOOR MOUNTING
IS DESIRED. REFER TO SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
ELEVATION
PLAN
M
IN
MIN
17”
CLEAR FLOOR SPACE AT
LAVATORY
SECTION
LAVATORY CLEARANCE
ACCESSIBLE LAVATORY
FRONT APPROACH SECTION
ACCESSIBLE LAVATORY
FRONT APPROACH
NOTE:
EQUIPMENT
PERMITTED IN
SHADED AREA
LAVATORY CLEARANCE
FINISHED
FLOOR
CLEARANCE
6" MAX TOE
MIN
11"
FOR EQUIPMENT
17”
MIN CLEARANCE
M
IN9
"2
M
IN
M
IN
M A
X
M A
X7
M
IN
CLEARANCE
8" MIN KNEE
OPENING
30”
CLEAR
48" MIN
STANDARD ACCESSIBLE TOILET ROOM
PLAN DESIGNATION T1
F1
T1
G1
B9
A1
6"
36" X 48" CLEAR
SPACE DOOR
SWING OUT
FRONT TRANSFER TOILET
CLEAR SPACE 3'-6" X 6'-0"
66" TURNING CIRCLE
1' - 6" 1' - 6"
7' - 6"
K1
54" X 60" CLEAR SPACE
DOOR SWING IN
30" X 48" LAVATORY
CLEAR SPACE
DOOR SWING IN/OR
OUT AS SHOWN ON
FLOOR PLAN
TOILET COMPARTMENT
WHEELCHAIR ACCESSIBLE
END OF ROW
G1 AT FEMALE
TOILET ONLY
A T
W A
L L
H U
N G
L O
N G
F
IX
T U
R E
S
A T
W A
L L
H U
N G
L O
N G
F
IX
T U
R E
S
A T
F L O
O R
M O
U N
T
A
T W
A L
L M
O U
N T
30" X 48" CLEAR
FLOOR SPACE
A T
W A
L L
H U
N G
L O
N G
F
IX
T U
R E
S
A T
W A
L L
H U
N G
L O
N G
F
IX
T U
R E
S
4"
V1
R1
STANDARD
ACCESSIBLE LAVATORY
PLAN DESIGNATIONS L1, L2
SECTION L4PLAN DESIGNATION L4
1' - 3"
A C
C E
S S
IB
L E
L A
V
M A
X A
T
FINISH
FLOOR
LAV
COUNTER
MIRROR
INSULATE
PIPING
MAX
2' - 1"
M A
X T
O R
IM
J1
A1
J1
R1
K1
K1
E16
BOTTLE
FILLERJSN #
JSN # A1067
A1066
A5090 A5145
A5200 A5109
A5107
SANITARY NAPKIN
TAMPON DISPOSAL
(WOMEN'S AND
UNISEX ONLY)
A
G1 SURFACE
MOUNTED
G3 PARTITION
MOUNTED
T O
T O
P
A5090
JSN # F3050
JSN #
UTILITY SHELF,
MOP BROOM
HOLDER
B
A5135
ACCESSORY
MOUNTING RAIL
B
A1132
DIAPER
CHANGING
STATION
SURFACE
MOUNTED
C
A4995
T O
T O
P
M A
X
REF. A3.50/ 06
FRONT TRANSFER
CLEAR AREA
3'-6" X 6'-0"
SWING UP
GRAB BAR
SB PARTITION
MOUNTED
C
D AT BARIATRIC
CONDITIONS ONLY
REF. A3.02/ 10
CONTRACTOR
PROVIDED AND
INSTALLED
SB
SB
REF. A3.50/ 06
REF. A3.60/ 10
MEN'S TOILETS
1A-136
WOMEN'S
TOILETS
1A-134
5' - 7" 5' - 4 1/2"
"L1
L1
S4 S2
S2
U1U1
5' - 1"
5' - 1" ø 5
6" ø 5' - 6
C L R
FD
FD
3' - 6"
4' - 0"
A4995
122 SF
MALE
143 SF
FEMALE
L1
L1
U1S4
S2S2
EWC3
A4995
A5077A5077
A5080 A5080 A5075A5075
A
A
A
A ø 5
6" ø 5
6"
FD
FD
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUSAESUS
A3.23
TOILETS & STANDARD ACCESSORIES
1/4" = 1'-0"01 LEVEL 1 - TOILETS
1/4" = 1'-0"02 LEVEL 2 - TOILETS
WALL AND CORNER GUARDS SCHEDULE SCALE: 3" = 1' - 0"
WALL AND CORNER GUARDS SCHEDULE SCALE: NTS CONTINUED LOCKER SCHEDULE SCALE: 1/4" = 1' - 0"
WP-1
BASE AS SCHEDULED
FLOOR
CRASH RAIL OR BUMPER
GUARD AS SCHEDULED
JOINT MOULDING
WALL PROTECTION
PANEL MOUNTED ABOVE
BASE BOARD
SCHLUETER MOULDING
HANDRAIL OR CRASH
RAIL AS SCHEDULED
M
IN1
BASE AS SCHEDULED
FLOOR
CRASH RAIL OR BUMPER
GUARD AS SCHEDULED
HANDRAIL OR CRASH
RAIL AS SCHEDULED
WALL
PROTECTION
ABBREVIATION
DESCRIPTION
MOUNTING DETAIL -
REFER TO SHEET A.302
ABBREVIATION
DESCRIPTION
CR-1
B
CRASHRAIL
B
INTEGRAL CRASHRAIL
WITH HANDRAIL
WOOD PATTERN FRP,
REFER TO INTERIOR
DESIGN SELECTIONS
HR
STANDARD
MOUNTING HEIGHTS
48" HIGH
CORNER
GUARD
SURFACE MOUNTED
CG-1
STAINLESS STEEL
NOTE: TERMINATE CRASH RAILS 3" FROM:
• DOOR FRAME
• EDGE OF DOOR AT FULLY OPEN POSITION
• CASEWORK
• CORNER GUARD
• PARTITION INTERSECTION AND OTHER OBSTRUCTIONS
NOTE: DIAGRAMS ARE FOR
REFERENCE TO BACKING
INFORMATION ONLY AND
EXACT PROFILES MAY
VERY. REFER TO INTERIOR
DESIGN DRAWINGS
1 1/4"
3"
/8
3 1/2"
/2
STANDARD / WARDROBE
C1
TRIPLE
TIER
LOCKER CODE FOR PLANS:
1.
2.
3.
STYLE OF LOCKER: TYPE C.
MATERIAL:
M - METAL
TOP CONFIGURATION:
LS - LOW SLOPED TOP
LOCKER CODE: C1: C-15-18-72-M-LS
STYLE
WIDTH
DEPTH
LOW SLOPED TOP
MATERIAL
HEIGHT
ON PLAN SHEET
9-C1
QUANTITY
LOCKER CODE
9 TYPE C1 LOCKERS
C1: C-15-18-72-M-LS
LOCKER SCHEDULE
TYPE STYLE WIDTH DEPTH HEIGHT MATERIAL TOP
L1 - 6" base L 1' - 3" 1' - 6" 6' - 0" M -
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUSAESUS
A3.24
LOCKERS, ACCESSORIES, WALL PROT,
EQUIP
C1 C LS
FOR REFERENCE ONLY - ALL LOCKERS ARE OWNER PROVIDED AND INSTALLED
2" 5/8"
P A
R T
N S
C H
E D
/2
/1
/1
V A
R
IE
S
APPLIED STOP AT
GLAZING
TYPICAL -
HOLLOW METAL
1 2
CASE OPENING
MUNTIN
P A
R T
N S
C H
E D
/2
" 2" 2" 1/2"
APPLIED
STOP AT
GLAZING
TYPICAL -
ALUMINUM
1 1/2"
/4
P A
R T
N
S C
H E
D
NOT USED
NOT USED
SAFETY GLASS LOCATIONS DOOR LEGEND
NOTE:
NOT ALL CONDITIONS SHOWN BELOW ARE APPLICABLE TO THE SCOPE OF WORK.
GLASS SCHEDULE
GLASS PRODUCT SCHEDULE FOR WALLS AND DOORS
NP - NOT PERMITTED
A - ACCEPTABLE
NR - NOT RECOMMENDED
FIRE -RATED
NON-FIRE -RATED
SAFETY NOT REQUIRED
SAFETY NOT REQUIRED
SAFETY REQUIRED
SAFETY REQUIRED
NP
NP
NP
A A A A
A
AA
A
NP NP
NP NP NP
NP
NR
NR
A N
N E
A L E
D
W
IR
E D
T E
M P
E R
E D
L A
M
IN
A T
E D
F
IR
E
R A
T E
D
SAFETY GLAZING (SG) IS REQUIRED FOR
CLOSE PROXIMITY TO DOORS GLAZED OPENINGS IN DOORS
SG
SG
SG
SG
SG
SG
SG
SG
SG
SG
SG
SG
0 " 24
0 "
GLAZED OPENINGS IN PARTITIONS
36" * 36" *
EXTERIORINTERIOR
SAFETY
BARS
FLOOR WALKING
SURFACE
SAFETY GLASS IS REQUIRED WHEN ALL OF
THE FOLLOWING CONDITIONS ARE PRESENT
* TOP OF GLAZING IS GREATER THAN / EQUAL
36" AFF
* AREA OF SINGLE PANE > 9 SF
* BOTTOM OF GLAZING IS LESS THAN / EQUAL
18" AFF
* WALKING SURFACE IS LOCATED WITHIN 36"
OF ONE OR BOTH SIDES
EXCEPTION:
GLASS DOES NOT NEED TO BE SAFETY GLASS
WHEN 1 1/2" SAFETY BAR IS INSTALLED WHERE
WALKING SURFACE IS WITHIN 36" OF GLASS
EXTERIORINTERIOR
SAFETY
BARS
FLOOR
GRADE
F T
SAFETY GLASS IS REQUIRED AT INTERIOR
LITE WHEN BOTTOM OF GLAZING IS LESS
THAN / EQUAL 18" AFF
EXCEPTION:
INTERIOR LITE DOES NOT NEED TO BE
SAFETY GLASS WHEN 1 1/2" SAFETY BAR IS
INSTALLED
SAFETY GLASS IS REQUIRED FOR EXTERIOR
LITE EXCEPT WHEN THE BOTTOM OF THE
GLAZING IS GREATER THAN / EQUAL 25 FT
ABOVE GRADE
DOOR NOTES
1. CONTRACTORS TO USE THE ARCHITECT'S FLOOR PLAN DESIGNATION DOOR NUMBER IN ADDITION TO THE ROOM NUMBER ON ALL SHOP DRAWING
SCHEDULE
SUBMITTALS.
DOOR TYPESVISION PANELS, LOUVER TYPES, AND ACCESSORIES
DOOR AND BORROWED LITE FRAME TYPES SCALE: 1" = 1' - 0"
DOOR PLAN DESIGNATION
SUFFIX FOR MULTIPLE
DOORS AT A ROOM
DOOR NUMBER SAME
AS ROOM NUMBER
4" MIN
6" PREFERRED
OPENING MIN CLEAR
1' - 6" (PULL SIDE)
CLOSER AND LATCH
1' - 0" (PUSH SIDE) MIN
CLEAR IF DOOR HAS
DOOR OPENING LOCATION
A. DOORS SHOWN ADJACENT TO A FLANKING WALL OR OTHER FIXED OBSTRUCTION, SHALL BE LOCATED AS SHOWN ABOVE.
B. OTHER LOCATIONS SHALL BE ON CENTERLINE OF ROOM OR AS SPECIFICALLY DIMENSIONED.
DOOR FIRE RATING101X
VISION PANEL
OR LOUVER
ACCESSORY
LOCATION OF
HOLD OPEN
SYMBOL, IF
APPLICABLE
DOOR LEGEND
DOOR NOTES
1. CONTRACTORS TO USE THE ARCHITECT'S FLOOR PLAN DESIGNATION DOOR NUMBER IN ADDITION TO THE ROOM NUMBER ON ALL SHOP DRAWING
SCHEDULE SUBMITTALS.
CONTROL JOINT AT DOOR FRAMES
SINGLE DOORS
ALIGN WITH EDGE
OF DOOR FRAME
CORNER ON HINGE
SIDE
DOUBLE DOORS
ALIGN WITH
EDGE OF DOOR
FRAME
CORNER
NON-RATED
OR
RATED 20/45 MIN
MIN
6"
X
M
IN6
Y
RATED
20/45 MIN
X
M A
X
Y
1296 SQ IN MAX
6" 6"
ACCESSORIES
A T
A C
C E
S S
IB
L E
”5
LOCK BAR
* - NOT ALLOWED AT SHOWER ENCLOSURES
SINGLE DOORS
4' X 8' GYP BD
PANEL
CONFIGURATION
DOUBLE DOORS
GYPSUM BD CONFIGURATION AT DOORS
BOTTOM OF
STRUCTURE
4' X 8' GYP BD
PANEL
CONFIGURATION
BOTTOM OF
STRUCTURE
V A
R
IE
S
V A
R
IE
S
V A
R
IE
S
EXTEND CJ TO BOTTOM
OF STRUCTURE AT
RATED WALLS 4" ABOVE
CEILINGS AT NON-RATED
WALLS
CASED OPENING
ALIGN WITH EDGE
OF CASED OPENING
ARMOR PLATE
KICK PLATE
KICK/ARMOR PLATE LEGEND:
K: KICK PLATE
A: ARMOR PLATE
1. DOOR PUSH SIDE
2. DOOR PULL SIDE
3. BOTH SIDES
EXAMPLE: K1 = PUSH SIDE KICK PLATE
EXTEND CJ TO
BOTTOM OF
STRUCTURE AT RATED
WALLS 4" ABOVE
CEILINGS AT NON-
RATED WALLS
EXTEND CJ TO BOTTOM OF
STRUCTURE AT RATED WALLS
4" ABOVE CEILINGS AT NON-
RATED WALLS
LOCATION OF
POWER
OPERATION
SYMBOL, IF
APPLICABLE
DOOR DEVICE
SYMBOL
SYMBOL
LOCATED ON
SIDE OF DOOR
DEVICE TO BE
INSTALLEDSYMBOL LEGEND
SECURITY DEVICE
PROXIMITY
SENSOR
DELAYED EGRESS
FREE EGRESS
POWER
OPERATOR
HOLD OPEN
PUSH PLATE
NON RATED
X6" 6"
A1 A2
FLUSH
SINGLE
FLUSH
DOUBLE
Q2
ALUMINUM
BI-PARTING DOUBLE
AUTOMATIC SLIDER
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUSAESUS
A3.31
DOOR, SAFETY GLAZING AND LOUVER
INFORMATION
DOOR SCHEDULE
MATERIALS AND FINISHES DETAILS CONTROLS
1st Floor
100A 13' - 8 1/2" 7' - 0" ALM ALM 14/A7.10 15/A7.10 CARD
READER
100A
100B 13' - 8 1/2" 7' - 0" ALM ALM 16/A7.10 SIM 13/A7.10 SIM CARD
READER
100B
- RECEPTION 102 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 102
- HAC 103 3' - 0" 7' - 0" A1 1 HM P-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 5D-1 103
- NON-GENDER RESTROOM 104 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2G 104
- SECURITY OFFICE 105 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - SH-3 CARD
READER
- QUIET ROOM 106 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 106
- EXAM ROOM 107 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 107
- OFFICE 108 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 108
- OFFICE 109 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 109
- OFFICE 110 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 110
- OFFICE 111 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 111
- OFFICE 112 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 112
- OFFICE 113 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 113
- OFFICE 114 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 114
- OFFICE 115A 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 115A
- OFFICE 115B 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 115B
- OFFICE 116 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 116
- CORRIDOR 117 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - X - 6F CARD
READER
- OFFICE 118 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 118
- HAC 119 3' - 0" 7' - 0" A1 1 HM P-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 5D 119
120A 13' - 8 1/2" 7' - 0" ALM ALM 16/A7.10 13/A7.10 CARD
READER
120A
- CORRIDOR 120B 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - 4 - - - SH-3 CARD
READER
120B
- 122 3' - 0" 7' - 0" A1 HM EP-1 HM EP-1 - 04/A7.10 07/A7.10 - 2 - - - SH-12 CARD
READER
- ELEVATOR EQUIPMENT 123 3' - 0" 7' - 0" A1 1 HM P-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - 5G 123
- NON-GENDER RESTROOM 124 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2G 124
- NON-GENDER RESTROOM 126 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2G 126
- 127 3' - 0" 7' - 0" A1 HM EP-1 HM EP-1 45 04/A7.10 07/A7.10 - - - - - SH-12 CARD
READER
- STORAGE 128 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - 5B - 128
- CONFERENCE 129 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 129
- CORRIDOR 130 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - 2 - - - 6C 130
- CORRIDOR 130B 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - 2 - - - 6C 130B
- STAFF WORK AREA 131 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3G 131
- OCCUPATIONAL THERAPY 132A 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 132A
- OCCUPATIONAL THERAPY 132B 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 132B
- SMALL GROUP 133 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 133
- TOILETS 134 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 1 134
- SMALL GROUP 135 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 135
- TOILETS 136 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 1 136
- SMALL GROUP 137 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 137
- COMPUTER LAB 138 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 138
- SMALL GROUP 139 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 139
- 140 3' - 0" 7' - 0" A1 HM EP-1 HM EP-1 45 04/A7.10 07/A7.10 - - - - - SH-12 CARD
READER
- FOOD STORAGE 141 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 45 01 / A3.33 02 / A3.33 GL-02 2 - - - 5B - 141
- RESOURCE LIBRARY 142 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 142
144A 13' - 8 1/2" 7' - 0" ALM ALM 16/A7.10 15/A7.10 CARD
READER
144A
- MULTIPURPOSE 144B 6' - 0" 7' - 0" A2 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - X X 12H 144B
- MULTIPURPOSE 144C 6' - 0" 7' - 0" A2 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 4 - - - 10D 144C
2ND FLOOR
- CORRIDOR 200A 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 4 - - X 6C-2 200A
- CORRIDOR 200B 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - SH-3 CARD
READER
200B
- 202 3' - 0" 7' - 0" A1 HM P-2 HM P-2 - 01/A3.33 02/A3.33 - - - - - SH-4 CARD
READER
- ELECTRICAL 203 3' - 0" 7' - 0" A1 1 HM P-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 5D-1 203
- HAC 205 3' - 0" 7' - 0" A1 1 HM P-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 5D 205
- LACTATION ROOM 207 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2G 207
- TOILETS 209 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 1 209
- CORRIDOR 210 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - X - 6F CARD
READER
- TOILETS 211 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 1 211
4 OFFICE 212 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 212
4 OFFICE 213 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 213
4 OFFICE 214 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 214
4 OFFICE 215 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 215
4 PIV LAB 216 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 216
4 OFFICE 217 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 217
4 PIV LAB 218 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 218
4 OFFICE 219 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 219
4 CORRIDOR 220A 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - X - 6F CARD
READER
220A
4 CORRIDOR 220B 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 6C 220B
4 OFFICE 221 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 221
- EXAM ROOM 222 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 3G 222
- OFFICE 223 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 223
- EXAM ROOM 224 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 3G 224
- OFFICE 225 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 225
- CORRIDOR 230A 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - SH-3 CARD
READER
230A
- OFFICE 231 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 231
- CLEAN UTILITY 232 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - SH-3 CARD
READER
- OFFICE 233 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 233
- CPAP STORAGE 234 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - SH-3 CARD
READER
- OFFICE 235 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 235
- SOILED UTILITY 236 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - SH-3 CARD
READER
- OFFICE 237 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 237
5 SHARED OFFICE 239 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 239
- CORRIDOR 240A 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 6C 240A
5 CLEAN LINEN 241 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - SH-3 CARD
READER
- CORRIDOR 242 4' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - X 6C-2 242
5 SLEEP 243 4' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 243
5 SLEEP 244 4' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 244
5 TOILET 245 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 245
5 TOILET 246 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 246
5 SLEEP 247 4' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 247
5 TOILET 249 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 249
5 SLEEP 250 4' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 250
5 TOILET 252 3' - 6" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 - - - - - 2C 252
- 254 3' - 0" 7' - 0" A1 HM EP-1 HM EP-1 - 04/A7.10 07/A7.10 - - - - - SH-4 CARD
READER
- CONFERENCE 261A 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 261A
- CONFERENCE 261B 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3E 261B
3 OFFICE 262 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 262
- IDF 263 4' - 0" 7' - 0" A1 1 HM P-1 HM P-1 45 01 / A3.33 02 / A3.33 - - - - - SH-3 CARD
READER
3 OFFICE 264 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 264
3 OFFICE 265 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 265
3 OFFICE 266 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 266
3 OFFICE 268 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 268
3 OFFICE 270 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 270
3 OFFICE 272 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 272
3 OFFICE 274 3' - 0" 7' - 0" A1 1 WD DF-1 HM P-1 - 01 / A3.33 02 / A3.33 GL-02 2 - - - 3B 274
X
2' - 0 3/4"
19”
13”
10"
6"
NOTE:
DO NOT CUT VERTICAL
STUD FLANGES
NOTE:
REFER TO SHEET A3.02
FOR MOUNTING DETAILS
2' - 0" 2' - 0 3/4" 2' - 0"
MOUNTING
SUPPORT
TYPE
2' - 0"
1' - 3"
UPPER
CABINET
BEYOND
MOUNTING
SUPPORT
TYPE
1' - 0"
5"BASE
CABINET
BOX, BOX,
BOX, BOX,
DRAWERS
FS FS
3" MAX
1 1/2" MIN
PLAN - INSIDE CORNER
FILLER PANELS BETWEEN
ADJACENT CABINETS
4" MAX
2 1/4" MIN
1/8”
COUNTERTO
P
1/8”
1/8”
END
PANEL
OR
CABINET
BEYOND
1/8” 1/8”
SECTION - UPPER
CABINET FASCIA
PANEL RETURN
1”
SCRIBE TO
BACK WALL
CABINET
BOTTOM
LINE OF
WALL
SECTION - UPPER
CABINET - BOTTOM OF
BACK WALL
LINE OF
WALL
PLAN - AT OUTSIDE
CORNER OF
COUNTERTOPS
4”
SECTION -
CABINET DOOR
AT BASE
MAX
6”
COUNTERTOP
SUPPORT
BRACKET. PAINT
TO MATCH WALL
COLOR
2”
EQ EQ
2”
UPPER
CABINE
T DOOR
2 1/2” 2"
PLAM TO
MATCH
CAB
PLAM TO
MATCH
CAB
FURR DOWN OR
ANGLED FASCIA
PANEL
1. CABINET WIDTHS TO BE BASED ON MODULE INCREMENTS OF 3" UNO.
2. PROVIDE FILLER PANELS TO FINISH OUT TO SCRIBE CABINETS TO WALL.
3. PROVIDE FILLER PANELS AND TRIM WHERE EQUIPMENT IS LOCATED WITHIN CABINETS.
4. PROVIDE FINISHED END PANELS END RETURNS AT OPEN ENDED CABINETS, KNEE SPACES, AND
ACCESSIBLE SINKS.
5. PROVIDE 1 1/2" THICK FINISHED END PANEL AT FREE STANDING END OF ACCESSIBLE SINKS AND KNEE SPACES.
6. WHEN FILLER PANELS ARE REQUIRED AT BOTH ENDS OF CASEWORK TERMINATION, BOTH FILLER PANELS
SHALL BE EQUAL WIDTH.
7. PROVIDE WALL BRACKET SUPPORTS AT 36" OC MAX TO SUPPORT COUNTERTOP AT CONTINUOUS KNEE SPACE.
8. PROVIDE END SPLASH WHEN COUNTERTOP IS ADJACENT TO WALL AT SIDES.
FASCIA PANEL JOINTS
8'-0" MAX BETWEEN
CL
OF
CONTROL
S
MIN
13”
MIN
10"
4 1/4" 12 3/4” 2"
19" MAX
5 1/ 2"
PLAN
3" = 1' - 0"
2" X 2" X 3/16" STL TUBE
POST WELDED TO BASE
PLATE
3/4" 3/4"
4"
3" UNO
SANDWICH PLATE
BETWEEN TWO 18 GA MTL
STUDS - PROVIDE 4 EA
3/8" DIA THRU BOLTS AT
EACH END OF PLATE
CONT 3 1/4" X 3/8" STEEL
PLATE. COORDINATE
PROFILE OF PLATE WITH
LAVATORY. DASHED LINE
INDICATES LOCATION OF
BENT PLATE AND PLYWOOD
BACKING AT ANGLED
CONDITIONS
PLAN
design
Architecture, Engineering, and Sustainable Design
Construct Facility for Mental Health and Primary Care Alternative ModalitiesCABINET DETAILS
COUNTER SUPPORT
SPAN 10' - 0" TO 16' - 0"
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
SCALE:
SCALE:
SCALE:
SCALE:
SCALE:
SCALE:
SCALE:
CLG HT AFF
REF RCP FOR
CLG HT AFF
REF RCP FOR
GENERAL NOTE
REFERENCE A3.00 AND A3.01 FOR PARTITION
TYPES AND FRAMING INFORMATION.
4 7/8"
T Y
P
3 5/8" METAL STUD
DIAGONAL
SUPPORT AT 48"
OC MAX
CLG AS SCHED
5/8" GYP BD ON
MTL STUDS
LINE OF
STRUCTURE
3 5/8" MTL STUD
HOR BRACING -
BRACE AT 24" OC
WHEN VERTICAL
HEIGHT EXCEEDS
48"
3 5/8" MTL STUDS
AT 16" OC
2" X 22 GA
CONTINUOUS
METAL STRAP TYP
EACH SIDE
OF LIGHT
FIXTURE
REF PLAN DIM
REF PLAN DIM
2" X 2" X 22 GA
CONTINUOUS METAL
ANGLE
2" X 2" X 22 GA
CONTINUOUS METAL
ANGLE
5/8" GYP BD ON 3 5/8"
STUDS AT 16" OC
CEILING AS
SCHEDULED
2" X 22 GA
CONTINUOUS METAL
STRAP TYP
3 5/8" MTL STUD HOR
BRACING - BRACE AT
24" OC WHEN VERTICAL
HEIGHT EXCEEDS 48"
LINE OF STRUCTURE
WHERE PARTITION IS
RATED, CONTINUE GYP
BD TO STRUCTURE
2" X 2" X 22 GA
CONTINUOUS METAL
ANGLE
3 5/8" MTL STUDS AT
16" OC
LINE OF STRUCTURE
5/8" GYP BD ON 3 5/8"
STUDS AT 16" OC
CEILING AS
SCHEDULED
2" X 2" 22 GA
CONTINUOUS METAL
ANGLE
FRAMED GYP BD
CEILING SYSTEM
5/8" GYP BD ON 3 5/8"
STUDS AT 16" OC
3 5/8" METAL STUD
DIAGONAL SUPPORT
AT 48" OC MAX
CLG AS
SCHEDULED
2" X 22 GA CONT MTL
STRAP, TYP
3 5/8" MTL STUD HOR
BRACING - BRACE AT
24" OC WHEN
VERTICAL HEIGHT
EXCEEDS 48"
LINE OF STRUCTURE
TYPICAL: 12 GA AT LAY-IN CLNG OR 8
GA AT GYP BD CLG VERTICAL HANGER
WIRE AT 4'-0" EA WAY W/ MIN 3 TIGHT
TURNS IN 1 1/2" BOTH ENDS OF WIRE
TYPICAL (8" OUT FROM WALL TYP)
12 GA AT LAY-IN CLG OR 8 GA AT GYP BD
CLG BRACING WIRE W/ MIN 4 TIGHT
TURNS IN 1 1/2" BOTH ENDS OF WIRE
TYP PROVIDED ORIENTED 90 TO EACH
OTHER AT 12'-0" OC 1ST POINT 6' FROM
EACH WALL
COMPRESSION STRUTS: 1 1/2" DEEP
20 GA WALL STUD ATTACH TO MAIN
RUNNERS WITH 1/4" MACHINE BOLT
AND TO STRUCTURE WITH 3/16"
DIAMETER POWER-DRIVEN
FASTENER. COMPRESSION STRUT
SHALL NOT REPLACE HANGER WIRE
MAIN RUNNER
CROSS RUNNER
2" (MAX) FROM BRACING
WIRES TO CROSS RUNNERS
CEILING
FIXTURE 4
MAX
(TYP)
12 GA AT LAY-IN CLG OR 8 GA AT
GYP BD CLNG WIRE ATTACHED
TO OPPOSING CORNERS AT
FIXTURES DIAGONAL
1. ICBO (INTERNATIONAL COUNCIL OF BUILDING OFFICIALS) EVALUATION REPORT - 4071 GYPSUM WALLBOARD (066). (THIS REPORT HAS THE SAME REQUIREMENTS FOR GYP BD CEILINGS AND LAY-IN
CEILING.
2. ALL LATERAL SUPPORTS MUST BE LOCATED A MIN OF 6" (152mm) FROM HORIZONTAL UNBRACED PIPES
AND DUCTWORK.
3. VERTICAL STRUTS FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO THE STRUCTURAL MEMBERS SUPPORTING THE ROOF OR FLOOR ABOVE. THE STRUT SHALL BE ADEQUATE TO
RESIST THE VERTICAL LOAD INDUCED BY THE BARRIER WIRES.
4. THE VERTICAL STRUTS AT HORIZONTAL RESTRAINT POINTS SHALL BE PLACED 12'-0" (3658mm) OC IN BOTH DIRECTIONS, WITH THE FIRST POINT WITHIN 6'-0" (1830mm) FROM EACH WALL.
NOTES
MAX.
MIN.
M A
X
STRUCTURE 13 GA. X
4 " WIDE
CEILING CLIP "HILTI"
OR EQUAL
4 TIGHT TURNS, TYP.
VERTICAL HANGER
WIRE 8 GA. MIN.
SAFETY WIRE, 8 GA.
MIN. CONNECTED TO
DECK
CONDUIT AND
CONNECTOR
RETAINER CLIP
GRID SPACING (CENTER TO CENTER) WIDTH (A): 6", 12", 24", 48"
LENGTH (B): 24", 48"
8 GA SPLAY BRACE
WIRES IN PLANE OF EA
RUNNER, VERTICAL
ANGLE 45 DEG MAX,
TYP. OF 4.
CROSS
RUNNERS
MAIN
RUNNERS
RUNNER, TYP. FOR 4
BRACING IN LINE WITH
NO. 8 GA. SPLAY WIRE
MAIN RUNNER
TYP. FOR 4
45 MAX.
8 GA SPLAY WIRES
@ 4'-0" O.C.-WHERE OCCURS
NO. 8GA HANGER WIRE
TYP.
2' MAX
CROSS TEE
DISTANCE FROM
CEILING TO STRUC.
ABOVE
0' TO 5'-0"
5'-0" TO 8'-0"
STRUT SIZE
2" X 2" X 1/8"
STEEL ANGLE
3" X 3" X 3/16"
STEEL ANGLE
4 TIGHT TURNS
WITHIN 1 1/2" OF
END, TYP AT EA
END
NOTE:
1. COMPRESSION STRUT IS TO BE INSTALLED AT CROSS RUNNER
INTERSECTION.
2. DIAGONAL BRACING WIRES ARE TO BE INSTALLED WITHIN 2" OF
CROSS RUNNER INTERSECTION.
3. COMPRESSION STRUCT IS NOT TO BE INSTALLED IN PLACE OF
VERTICAL HANGER WIRE.
KL/R < 200
WIRE SHALL BE ATTACHED
TO SUSPENDED MEMBERS
W/ A MIN. OF 4 TURNS
VERTICAL HANGER
(2) #12 SDST
SCREWS AT STRUT
TO MAIN RUNNER
STEEL ANGLE
COMPRESSION
STRUT (SEE DTL 5),
FREE SIDE
FIXED SIDE
F
IX
E D
S
ID
E
F R
E E
S
ID
E
NOTE:
1. 4'-0" MAX SPACING TO FIRST
BRACE LINE AT LEAST 96 SF BRACE
SPACING.
2. PROVIDE TRAPEZE OR OTHER
SUPPLEMENTARY SUPPORT
MEMBERS AT OBSTRUCTIONS TO
MAIN HANGER SPACING.
3. 8" MAX TO HANGER WIRE OR 1/4
THE LENGTH OF THE END RUNNER,
WHICHEVER IS LESS
LINE OF PERIMETER WALL
20 GA PERIMETER WALL ANGLE
CROSS RUNNER @ 2'-0" O.C.
8 GA VERTICAL HANGER WIRES @
4'-0" @ EA WAY MAX.
MAIN RUNNER @ 4'-0" O.C.
8 GA PERIMETER HANGER WIRES @
TERMINAL END OF EACH MAIN
RUNNER AND CROSS TEE
4 WAY 45 DEG DIAGONAL 8 GA WIRE
BRACING AND COMPRESSION STRUT.
ONE EVERY 96 SF MAX FOR OSHPD
8 GA MIN WIRE AT ALL 4 CORNERS OF
LIGHT FIXTURE AND AIR TERMINALS
NOTE:
ANGLE MOLDING
DRYWALL
MAIN BEAM
CROSS TEE
SPLAY WIRES
@ 4'-0" O.C.-WHERE OCCURS
NO. 8GA HANGER WIRE
- DRYWALL GRID SYSTEM SHALL BE INSTALL PER
MANUFACTURES SPECIFICATIONS
- WIRE SHALL BE ATTACHED TO SUSPENDED
MEMBERS W/ A MIN. OF 4 TURNS
DRYWALL
0.145" DIA HILTI "X-DNI"
WITH 1 1/2" EMBEDMENT
W/ WASHER
2 "
/ 2
8 "
A B
SEE NOTE 1
S E
E N
O T
E
TYP. VERTICAL HANGER WIRE ATTACHMENT
N.T.S.
TYP. FIXTURE SUPPORT
N.T.S.
TYP. SUSPENDED CEILING PLAN
N.T.S.
TYP. SUSPENDED CEILING DETAIL
NTS
TYP. SUSPENDED CEILING DETAIL
NTS
TYP. SUSPENDED CEILING
N.T.S.
TYP. SUSPENDED CEILING DETAIL
NTS
LINE OF CEILING
STL CHANNEL - CONT
C4 X 7.25
L 3" X 3" X 1/4" X 8"
WITH TWO - 1/2" DIA
EXPANSION
ANCHORS 2 1/4" MIN
EMBEDMENT
L 3" X 3" X 1/4" BRACE
AT EACH HANGER
ROD - WELD TO
HANGER ANGLE AND
CHANNEL
TOILET
COMPARTMENT
IF FURDOWN OCCURS
5/8" DIA STL HANGER
ROD AT 3'-0" OC -
WELD TO HANGER
ANGLE
L 3" X 3" X 1/4" X 5"
WITH TWO - 1/2" DIA
EXPANSION
ANCHORS 2 1/4" MIN
EMBEDMENT
LINE OF STRUCTURE
FINISH AFTER FABRICATION: SHOP PRIMER PAINT
4"
2" X 2" X 22 GA
CONT METAL
ANGLE
ACT CEILING AS
SCHEDULED
LINE OF
STRUCTURE
3 5/8" METAL STUD
DIAGONAL
SUPPORT AT 48" OC
MAX
EXTERIOR WALL
CONSTRUCTION
ALUM STOOL
TRIM
5/8" GYP BD ON 3 5/8"
STUDS AT 16" OC
SEALANT
ACT CLOSURE
PANEL TO
MATCH GRID
1 1/2" = 1'-0"03 FURR DOWN - HEADER DETAIL
1 1/2" = 1'-0"02 FURR DOWN SOFFIT DETAIL
1 1/2" = 1'-0"05
GYP BD/ACT
TRANSITION DETAIL
1 1/2" = 1'-0"04 SOFFIT DETAIL
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUSAESUS
A3.60
CEILING DETAILS
1 1/2" = 1'-0"11
CEILING GRID ATTACHMENT
FOR SEISMIC CONDITION
1" = 1'-0"12 SUSPENDED CEILING DETAILS
1" = 1'-0"10
CEILING MOUNTED TOILET
COMPARTMENT SUPPORT
1 1/2" = 1'-0"01 WINDOW POCKET CEILING DETAIL
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
1236 1.52.5
A5.1
A5.1 2' - 0"
1' - 11"
34' - 6" 7' - 0" 22' - 6" 2' - 6" 16' - 0"
82' - 6"
A6.1
LOBBY PARAPET
116' - 0"
SF-01
SF-02
T.O. SCREEN WALL
136' - 10"
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
1 2 3 61.5 2.5
A5.1
A5.1
16' - 0" 2' - 6" 22' - 6" 7' - 0" 34' - 6"
82' - 6"
A6.1
LOBBY PARAPET
116' - 0"
SF-03
SF-05 SF-05 SF-05
T.O. SCREEN WALL
136' - 10"
WALL PACK
LIGHTING
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
J H G F E ABC A.4
MAIN PRRC
ENTRANCE
D
A5.1
A5.1
A6.1
A6.1
11' - 1 1/2" 19' - 6" 19' - 6" 21' - 0" 21' - 0" 23' - 5" 12' - 7" 12' - 0" 12' - 0" 6' - 0" 1' - 4"
147' - 0"
LOBBY PARAPET
116' - 0"
SF-04
SF-07
SF-04
SF-05
SF-05 SF-05 SF-05SF--10
SF-04SF-04SF-04 SF-04SF-05SF-05SF-05SF-05SF-05SF-05
SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05
T.O. SCREEN WALL
136' - 10"
5 5
10 10
9 9
PRRC SIGN AND
INSTALLATION
PROVIDED BY VA.
2ND FLOOR SIGN AND
INSTALLATION
PROVIDED BY VA.
WALL PACK
LIGHTING
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
JHGFEA B CA.4 D
A5.1
A5.1
MECHANICAL
SCREEN
1' - 4" 6' - 0" 12' - 0" 12' - 0" 12' - 7" 23' - 5" 21' - 0" 21' - 0" 19' - 6" 19' - 6"
1' - 6 1/4" 147' - 0"
LOBBY PARAPET
116' - 0"
SF-08SF-10
SF-05 SF-05 SF-05 SF-05
SF-08SF-08SF-08SF-04
SF-05 SF-05 SF-05 SF-05SF-06 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05 SF-05SF-06 SF-06 SF-06
T.O. SCREEN WALL
136' - 10"
EIFS 01 GRAY #5B616B
Benjamin Moore™ DC-46 Bullock Gray
EIFS 02 GRAY-LIGHT #AEB0B5
Benjamin Moore™ 2133-50 Pigeon Gray
EIFS 03 GRAY-LIGHTER #D6D7D9
Match of Behr™ MQ3-25 Gray Shimmer *
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
KEY PLAN NTS
NORTH
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Dwg. of
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUS
PROJECT
AREA
MAIN
HOSPITAL
A4.1
ELEVATIONS
1/8" = 1'-0"01 NORTH
1/8" = 1'-0"02 SOUTH
1/8" = 1'-0"03 EAST
1/8" = 1'-0"04 WEST
1. ALL EXTERIOR WINDOW FRAME SYSTEMS ARE THERMALLY BORKEN FRAMES.
2. ALL WINDOW UNITS ON THE EXTERIOR OF THE BUILDING ARE TO BE 1" INSULATED,
THERMALLY BROKEN, BLAST RESISTANT UNITS WITH LAMINATED SAFETY FILM TO
PREVENT SHARDS PER THE VA'S PSDM REQUIREMENTS
GENERAL NOTES
KEYED NOTES - ELEVATIONS
1 PRE-FINISHED MTL. COPING SYSTEM, COLOR TO MATCH ADJACENT WALL
SYSTEM
2 MECHANICAL EQUIPMENT SCREEN WALL
3 POLISHED ALUMINUM BACK-LIT VA BUILDING SIGNAGE. N.I.C.
4 2" EXTERIOR INSULATION AND FINISH SYSTEM, TYPICAL
5 4" EXTERIOR INSULATION AND FINISH SYSTEM
6 VERTICAL AND HORIZONTAL REVEALS IN EIFS, TYP.
7 PARAPET BEYOND
8 EIFS CONTROL JOINT
9 INSULATED GLAZING IN THERMALLY BROKEN FRONT-GLAZED ALUMINUM
STOREFRONT SYSTEM, TYP.
10 AUTOMATIC SLIDING GLASS DOOR
12 INSULATED HM DOOR AS SCHEDULED, PAINT TO MATCH ADJACENT WALL
14 ROOF MOUNTED JIB CRANE WITH WINCH (SPILL 911 WTJ203DC OR VA
APPROVED EQUAL)
FINISH LEGEND
NOTE:
• GLAZING SYSTEM FRAMES TO BE CLEAR ANODIZED
• HOLLOW METAL DOORS AND FRAMES TO BE PAINTED TO MATCH
ADJACENT WALL
• COPING TO BE PREFINISHED IN SAME COLOR AS CORRESPONDING WALL
16' - 3"
3' - 0" 2' - 1" 3' - 0" 2' - 1" 2' - 1" 4' - 0"
R.O.
16' - 5"
R .O
GL-01 GL-01 GL-01 SP-01 GL-01 GL-01
FINISH FLOOR LEVEL
A7.10
A7.01
A7.01
A7.10
COORIDINATE WITH SLIDING DOOR MANUF. FOR EXACT DIMIENSIONS
14' - 1"
38' - 3"
EQ1 EQ1 EQ2 EQ2 EQ2 EQ2 EQ1 EQ1 EQ1 EQ1 EQ1 EQ1
R .O
R.O.
38' - 5"
FINISH FLOOR LEVEL
GL-01
GL-01
GL-01
GL-01
GL-01 GL-01 GL-01 GL-01 GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
SP-01
SP-01
A7.10
A7.01
A7.01
A7.10
A7.10
A7.10
A7.10
A7.10
A7.10
A7.10
GL-01 GL-01 GL-01 GL-01 GL-01
FINISH FLOOR LEVEL
R .O
R.O.
16' - 7"
16' - 5"
3' - 1" 2' - 1" 2' - 1" 4' - 0" 2' - 1" 3' - 1"
A7.10
A7.01
A7.01
GL-01
FINISH FLOOR LEVEL
2' - 1" 2' - 1" 3' - 6"
R.O.
7' - 10"
7' - 8"
R .O
GL-01 GL-01 GL-01
A7.10
A7.01
A7.01
FINISH FLOOR LEVEL
VERIFY OPENING WITH SLIDING DOOR MANUFACTURER
EQ1 EQ1 EQ2 EQ2 EQ1 EQ1
ALIGN FRAME WITH SLIDING DOOR OPENING BELOW
14' - 0"
14' - 2"
R .O
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-013
A7.10
A7.01
A7.10
A7.10
A7.10
A7.10
2' - 6"
2' - 8"
R .O
FINISH FLOOR LEVEL
GL-01
A7.01
A7.01
FINISH FLOOR LEVEL
R .O
14' - 6"
14' - 4"
4' - 1" 2' - 1" 2' - 1" 3' - 0" 3' - 1"
GL-01GL-01GL-01GL-01GL-01
A7.10
A7.01
A7.01
FINISH FLOOR LEVEL
R .O
12' - 0" R.O.
12' - 2"
3' - 0" 3' - 0" 3' - 0" 3' - 0"
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
A7.10
A7.10
A7.01
A7.01
2' - 6"
2' - 8"
R .O
FINISH FLOOR LEVEL
SP-01
FINISH FLOOR LEVEL
MATCH R.O. WIDTH OF SLIDING DOOR BELOW
MATCH WIDTH OF SLIDING DOOR BELOW
EQ EQ EQ EQ
" GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
GL-01
A7.10
A7.10
A7.01
A7.01
LOBBY PARAPET LEVEL
116'-0"
1' - 8" EQ2 EQ2 1' - 8"
9' - 8"
R .O
GL-01 GL-01 GL-01 GL-01
BACK OF ENTRY VESTIBULE REF: EXTERIOR DIMENSION PLAN
1" 9' - 8" 1"
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Dwg. of
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUS
A4.2
ALUMINUM FRAME TYPES
1/2" = 1'-0"01 SF-01
1/2" = 1'-0"02 SF-02
1/2" = 1'-0"03 SF-03
1/2" = 1'-0"04 SF-04
NOTES:
1. DIMENSIONS INDICATED ON PLANS ARE TO THE FRAME, FRAMING SHALL BE
ADJUSTED TO ACCOUNT FOR ROUGH OPENING. FIELD VERIFY OPENING PRIOR
TO PROCUREMENT
2. REFER TO SPECIFICATIONS FOR GLAZING AND SPANDRAL GLASS TYPES
1/2" = 1'-0"07 SF-07
1/2" = 1'-0"05 SF-05
1/2" = 1'-0"08 SF-08
1/2" = 1'-0"09 SF-09
1/2" = 1'-0"06 SF-06
1/2" = 1'-0"10 SF-10
1/2" = 1'-0"11 SF-11
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
A5.1
A5.1
T.O. STEEL @ ROOF
127' - 4"
LOBBY PARAPET
116' - 0"
/A6.1 04
/A6.1 03
T.O. SCREEN WALL
136' - 10"
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 2
132' - 6"
A5.1
A5.1
TOP OF HIGH ROOF
129' - 8"
5 5
A6.1
LOBBY PARAPET
116' - 0"
/A6.1 07
/A6.1 09 /A6.1 08
WAITING VESTIBULE
/A7.01 11
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
A5.1
A5.1
/A7.51 12/A7.51 12
/A7.51 03 /A7.51 03
/A6.1 06
/A6.1 05
T.O. SCREEN WALL
136' - 10"
1st Floor 100' - 0"
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
PARAPET 2
132' - 6"
A5.1
A5.1
LOBBY PARAPET
116' - 0"
/A6.1 02
/A6.1 01
1050 E. Southern Ave, Suite #D, Tempe, Arizona 85282, (480) 751-9542 designgroup
Architecture, Engineering, and Sustainable DesignAESUS
Drawing Title: Project Title:
Date
Location
Checked
Building Number:
Project Number:
Drawing Number:
Drawn
Revisions: Date
CONSULTANTS: ARCHITECT/ENGINEERS: Office of Construction and Facilities Management
Construct Facility for Mental Health and Primary Care Alternative Modalities
Location:
100% Bid Set Submittal
August 18, 2023 o n e e ig h th in c h o n e fo o t
B
A
C
D
E
F th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
VA FORM
08-6231
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
Dwg. of
612-908
VANCHCS
10535 HOSPITAL WAY MATHER, CA 95655
AESUS
A5.1
BUILDING SECTIONS
1/8" = 1'-0"02 BLDG LONG SECTION 02
1/8" = 1'-0"03 BUILDING SHORT SECTION 01
1/8" = 1'-0"04 BLDG SHORT SECTION 02
1/8" = 1'-0"01 BLDG LONG SECTION 01
KEYED NOTES - BLDG SECTIONS
2 STAIR AND GUARDRAIL
4 INSULATED GLAZING IN THERMALLY BROKEN FRONT'GLAZED ALUMINUM
STOREFRONT SYSTEM
5 PRE-FINISHED MTL. COPING SYSTEM - CLEAR ANODIZED FINISH
7 PREFINISHED ALUMINUM GRAVEL STOP FLASHING
8 MECHANICAL SCREEN WALL
9 ROOF MOUNTED JIB CRANE WITH WINCH (SPILL 911 WTJ203DC OR VA APPROVED
EQUAL)
10 3'X3' ROOF ACCESS HATCH WITH FALL PROTECTION
11 4" EXTERIOR INSULATION AND FINISH SYSTEM
12 2" EXTERIOR INSULATION AND FINISH SYSTEM, TYPICAL
14 ROOF CURB, REF TO ROOF PLAN
15 RECESSED WALK-OFF MAT
2ND FLOOR
114' - 0"
PARAPET 1
130' - 10"
T.O. STEEL @ ROOF
127' - 4"
/A7.01 09
/A7.01 11
/A7.01 06
/A7.01 08
/A7.01 09
/A7.01 11
CONCRETE BEAM SEE
STRUCTURAL FOR
ADDITIONAL
INFORMATION
15 MIL UNDERSLAB VAPOR
RETARDER
CONCRETE SLAB
SLOPE OUTSIDE SILL
AWAY FROM BUILDING
LOW-E INSULATED
GLAZING IN
THERMALLY BROKEN
FRONT-GLAZED
SYSTEM
6" METAL STUD WITH BATT
INSULATION AND 5/8" GYP.
BD. (INTERIOR SIDE)
SPRAY FIRE PROOFING
ON BEAMS AND
DECKING
CONCRETE SLAB ON METAL
DECKING
THICKNESS OF INSULATION
VARIES AT ROOF EDGES.
MINIMUM OF 5" BASE
INSULATION SLOPED AT 1/4"
PER FOOT MINIMUM. SEE
ROOF PLAN.
SPRAY FIRE PROOFING ON
BEAMS AND DECKING
SINGLE PLY TPO MEMBRANE
ROOF SYSTEM OVER 5/8"
DENSDECK OR VA APPROVED
EQUAL AND TAPERED RIGID
INSULATION (R-30 MIN.) OVER
1/2" METAL DECK
PRE-FINISHED MTL. COPING
SYSTEM FINISH TO MATCH
CORRESPONDING WALL
COLOR
2" EXTERIOR
INSULATION AND
FINISH SYSTEM
CONTINUOUS
AIR/WATER BARRIER,
ALL OPENING EDGES
TAPED WITH BARRIER
FLASHING TAPE.
2" EXTERIOR
INSULATION AND
FINISH SYSTEM
LOW-E INSULATED
GLAZING IN
THERMALLY BROKEN
FRONT-GLAZED
SYSTEM
/A7.51 10
1st Floor
100' - 0"
2ND FLOOR
114' - 0"
PARAPET 2
132' - 6"
T.O. STEEL @ ROOF
127' - 4"
/A7.01 09
/A7.01 11
/A7.01 06
CONCRETE BEAM SEE
STRUCTURAL FOR
ADDITIONAL
INFORMATION
15 MIL UNDERSLAB VAPOR
RETARDER
CONCRETE SLAB
CONC. SIDE WALK TO TIE
INTO FF CONC. SLAB
BELOW DOOR SILL
ALUMINUM SLIDING
DOOR SYSTEM
6" METAL STUD WITH
POLYURETHANE SPRAY
INSULATION (THERMAX OR
EQUAL) AND 5/8" GYP. BD.
(INTERIOR SIDE)
SPRAY FIRE PROOFING
ON BEAMS AND
DECKING
CONCRETE SLAB ON METAL
DECKING
THICKNESS OF INSULATION
VARIES AT ROOF EDGES.
MINIMUM OF 5" BASE
INSULATION SLOPED AT 1/4"
PER FOOT MINIMUM. SEE
ROOF PLAN.
SPRAY FIRE PROOFING ON
BEAMS AND DECKING
SINGLE PLY TPO MEMBRANE
ROOF SYSTEM OVER 5/8"
DENSDECK OR VA APPROVED
EQUAL AND TAPERED RIGID
INSULATION (R-30 MIN.) OVER
1/2" METAL DECK
PRE-FINISHED MTL. COPING
SYSTEM FINISH TO MATCH
CORRESPONDING WALL
COLOR
2" EXTERIOR INSULATION AND
FINISH SYSTEM
CONTINUOUS AIR/WATER
BARRIER, ALL OPENING
EDGES TAPED WITH BARRIER
FLASHING TAPE.
2" EXTERIOR INSULATION AND
FINISH SYSTEM
LOW-E INSULATED
GLAZING IN
THERMALLY BROKEN
FRONT-GLAZED
SYSTEM
/A7.10 14
/A7.51 10
/A7.01 11 1st Floor
100' - 0"
B
/A7.01 08
/A7.10 09
/A7.10 03
CONCRETE BEAM SEE
STRUCTURAL FOR
ADDITIONAL
INFORMATION
15 MIL UNDERSLAB VAPOR
RETARDER
CONCRETE SLAB
1" EXTERIOR STUCCO
FINISH SYSTEM
1" EXTERIOR STUCCO
FINISH SOFFIT SYSTEM
PREFINISHED GRAVEL
STOP FLASHING
3' - 9"
1' - 10"
2" EXTERIOR INSULATION AND
FINISH SYSTEM
CONTINUOUS AIR/WATER
BARRIER, ALL OPENING
EDGES TAPED WITH BARRIER
FLASHING TAPE.
V A
R
IE
S
1st Floor
100' - 0"
This is the start of the file's text. The full file is on GovTribe.