Attachment 5 - DRAWING - SECOND FLOOR PLAN.pdf
PDF 247 KB Posted
- Attached to
- N063--702 MS Waco PACS Project Federal contract opportunity
- Solicitation number
- 36C25922Q0560
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 36C25922Q0560 A0002.docx | DOCX document | |
| 36C25922Q0560 A0001.docx | DOCX document | |
| 36C25922Q0560.docx | DOCX document | |
| Attachment 4 - DRAWING - FIRST FLOOR PLAN.pdf | ||
| Attachment 2 - 52.204-26 Covered Telecommunications Equipment or Services-Representation.docx | DOCX document | |
| Attachment 1 - 702 MS Waco PACS Project SOW.rtf | RTF text file | |
| Attachment 3 - DRAWING - BASEMENT FLOOR PLAN.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN DN
DN
DN DN
EXISTING
ELEVATOR
EXISTING
ELEVATOR
UNION OFFICE
TIME-MANAGEMENT
OFFICE
CM MONITORS
TELECOM
H.A.C.
ELECTRICAL
ROOM
TRAINING
LIBRARY
STAGING
AREA
TRAINING
OFFICE
TRAINING
ROOM
LOW
VOLTAGE
ELECTRICAL
ROOM
MOTHER'S
NURSING
BREAK ROOM
CM COACHES
OPEN OFFICE
322A
OPEN OFFICE
305A
CONFERENCE
ROOM
4' - 9"
CORRIDOR
REF.
REF.
AREA OF
REFUGE
AREA OF
REFUGE
OPEN OFFICE
322C
OPEN OFFICE
322B
OPEN OFFICE
305B
OPEN OFFICE
305C
PROGRAM
PROGRAM
PROGRAM
PROGRAM
PROGRAM
PROGRAM
EXIT 1
54 OCCUPANTS
EXIT 2
54 OCCUPANTS
EXIT 3
52 OCCUPANTS
EXIT 4
54 OCCUPANTS
EXIT 5
54 OCCUPANTS
15 416
300186
100127
100 PROGRAM
PROGRAM
PROGRAM
PROGRAM
FEC
FEC
FECFEC
FEC FEC
FEC
BASEMENT FLOOR
OCCUPANCY TYPE/ LOAD LEGEND
1 HR FIRE BARRIER
FIRE EXTINGUISHER & CABINET LOCATIONS - RECESSED
(MOUNTED 3' 3" TO B.O. CABINET)
MAXIMUM OCCUPANCY LOAD CALCULATIONS
NOT AVAILABLE
FEC
FIRST FLOOR
PROPOSED OCCUPANCY
USE: ASSEMBLY AREA
USE: STORAGE, MECHANICAL, ELECTRICAL, & TELECOM
AREAS
NOTE: REFER TO CODE SUMMARY SHEET A0.01 FOR MORE INFORMATION
USE: BUSINESS
OCCUPANT LOAD FACTOR PER NFPA TABLE 7.3.1.2120 100
AREA OF ROOM (SF.)
OCCUPANT LOAD
TRAVEL DISTANCE
WC
REQUIRED
8 15 (12)
TOTAL PLUMBING FIXTURE COUNT
PROVIDED
5 10 (8)
7 10 (8)
MALE FEMALE MALE FEMALE
15 (12)
10 (8)LAVS
DRINKING FOUNTAINS
SERVICE SINK 1 3 (2)
EXISTING OCCUPANCY
SECOND FLOOR
BASEMENT FLOOR
FIRST FLOOR
SECOND FLOOR
TOTAL
TOTAL
NOTE: 1. ( ) INDICATES THE NUMBER OF PLUMBING FIXTURES THAT ARE
EXISTING IN THE FIRST & SEOND FLOORS. THIS FIXTURE COUNT
IS INCLUDED IN THE TOTAL NUMBER OF FIXTURES PROVIDED.
2.THE HIGHER OCCUPANT NUMBER OF DESIGN VS. PROGRAM
LOAD WAS UTILIZED IN MAXIMUM OCCUPANT LOAD
CALCULATIONS ABOVE.
LEGEND
EXISTING SPACES TO REMAIN
EXISTING WALLS, STAIRS, & COLUMNS TO REMAIN
AREAS INCLUDED IN PHASE 3A PROJECT SCOPE
EXISTING DOOR & FRAME TO REMAIN
AREAS INCLUDED IN PHASE 3B PROJECT SCOPE
2.PROVIDE TEMPORARY WALL & DOOR IN PHASE 3A (AS
SHOWN ON PLAN). TEMPORARY DOOR 200 IS FOR
CONSTRUCTION ACCESS ONLY. GC TO PROVIDE DOOR
HARDWARE AND SIGN THAT AUTHORIZES ONLY
CONSTRUCTION PERSONNEL.
1.MAINTAIN EXISTING OCCUPANCIES IN AREAS THAT ARE NOT
IN SCOPE OF WORK.
NOTES:
CONCRETE INFILL (REFER TO STRUCT. DWGS)
4.DEMO TEMPORARY WALL IN PHASE 3B.
NEW DOOR IN EXISTING FRAME
NEW DOOR & FRAME
NEW ACCESS CONTROL DOORS
EXISTING ACCESS CONTROL DOORS
3.EXISTING DOOR IN LOBBY 123 TO REMAIN FOR STAFF
ENTRANCE DURING PHASE 3A CONSTRUCTION. ELEVATORS
ARE TO REMAIN IN OPERATION FOR ACCESS TO UPPER
FLOORS DURING PHASE 3A CONSTRUCTION.
4800 MEMORIAL DRIVE
WACO, TEXAS 76710
ARCHITECT/ ENGINEERS DRAWING TITLE: Project Title:
Location:
Date:
Project Number
Drawing Number
CONSULTANTS:
Date:
Building Number
PROJECT MANAGER:
CENTRAL TEXAS
VETERANS
HEALTHCARE
SYSTEM
o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
F
E
D
C
B
A
Revisions:
TASK ORDER NO.
CODE PLAN, SECOND FLOOR -
REFERENCE ONLY
A0.04
HRC BASEMENT RENOVATION -
PHASE 3A & 3B
674A4-10-243
FEBRUARY 18, 2011
FEBRUARY 18, 2011
BID DOCUMENTS
1/8" = 1'-0"1
CODE PLAN - SECOND FLOOR -
REFERENCE ONLY
PLAN NORTHTRUE NORTH
AMENDMENT MAY 26, 2011 (REPLACES FEBRUARY 18, 2011) 05/ 26 /11
File details come from the government source that posted it. Updated .