Attachment 4 - DRAWING - FIRST FLOOR PLAN.pdf

PDF 251 KB Posted

Attached to
N063--702 MS Waco PACS Project Federal contract opportunity
Solicitation number
36C25922Q0560
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 19

View the file

Other files for this federal contract opportunity

Other files attached to N063--702 MS Waco PACS Project, newest first.
File Type Posted
36C25922Q0560 A0002.docx DOCX document
36C25922Q0560 A0001.docx DOCX document
36C25922Q0560.docx DOCX document
Attachment 2 - 52.204-26 Covered Telecommunications Equipment or Services-Representation.docx DOCX document
Attachment 3 - DRAWING - BASEMENT FLOOR PLAN.pdf PDF
Attachment 5 - DRAWING - SECOND FLOOR PLAN.pdf PDF
Attachment 1 - 702 MS Waco PACS Project SOW.rtf RTF text file

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN DN

UP UP

UP

UP UP

UP

EXISTING

ELEVATOR

EXISTING

ELEVATOR

ELECTRICAL

ROOM

SENIOR

SUPERVISOR

MANAGER

OFFICE

EXECUTIVE

CONFERENCE

ROOM

STORAGE

SITE

MANAGER

OFFICE

RECEPTION

PROGRAM

SUPERVISOR

OFFICE

SUPERVISOR

MANAGER

OFFICE

VISITORS

OFFICE

SUPERVISOR

MANAGER

OFFICE

ELECTRICAL

ROOM

LOW

VOLTAGE

SUPERVISOR

MANAGER

OFFICE

SUPERVISOR

MANAGER

OFFICE

IT

SUPERVISOR

OFFICE

IT STAFF

WORK AREA

COMPUTER

ROOM

BREAK ROOM

OPEN OFFICE

226A

OPEN OFFICE

213ACORRIDOR

TELECOM

ROOM

HAC

219B

205A

AR

EA

O F

RE

FU

GE

OPEN OFFICE

226C

OPEN OFFICE

226B

OPEN OFFICE

213C

OPEN OFFICE

213B

300118

21125

15 61

4 126

100100100

100 100 100 100

PROGRAM

PROGRAM

PROGRAM

PROGRAM

PROGRAM

PROGRAM

EXIT 1

67 OCCUPANTS

EXIT 2

37 OCCUPANTS

EXIT 3

36 OCCUPANTSEXIT 5

36 OCCUPANTS

EXIT 6

37 OCCUPANTS

FEC

FEC

FECFEC

VEND.

FEC FEC

FEC

1 HR RATED PARTITION NOT

REQUIRED PER CODE. PARTITION

RATED AT REQUEST OF OWNER

FOR PROTECTION OF EQUIPMENT

CONTAINED IN COMPUTER ROOM.

EXIT NOT REQUIRED FOR THIS

FLOOR OR THIS ROOM PER

CODE. MAINTAINED FOR

CONVENIENCE BY REQUEST OF

PM/ COTR. A SIGN SHALL BE

PLACED ON DOOR, "NOT A

REQUIRED EXIT."

REQUIRED EXIT AND ACCESSIBLE

EXIT ACCESS PATH 219A

BASEMENT FLOOR

OCCUPANCY TYPE/ LOAD LEGEND

1 HR FIRE BARRIER

FIRE EXTINGUISHER & CABINET LOCATIONS - RECESSED

(MOUNTED 3' 3" TO B.O. CABINET)

MAXIMUM OCCUPANCY LOAD CALCULATIONS

NOT AVAILABLE

FEC

FIRST FLOOR

PROPOSED OCCUPANCY

USE: ASSEMBLY AREA

USE: STORAGE, MECHANICAL, ELECTRICAL, & TELECOM

AREAS

NOTE: REFER TO CODE SUMMARY SHEET A0.01 FOR MORE INFORMATION

USE: BUSINESS

OCCUPANT LOAD FACTOR PER NFPA TABLE 7.3.1.2120 100

AREA OF ROOM (SF.)

OCCUPANT LOAD

TRAVEL DISTANCE

WC

REQUIRED

8 15 (12)

TOTAL PLUMBING FIXTURE COUNT

PROVIDED

5 10 (8)

7 10 (8)

MALE FEMALE MALE FEMALE

15 (12)

10 (8)LAVS

DRINKING FOUNTAINS

SERVICE SINK 1 3 (2)

EXISTING OCCUPANCY

SECOND FLOOR

BASEMENT FLOOR

FIRST FLOOR

SECOND FLOOR

TOTAL

TOTAL

NOTE: 1. ( ) INDICATES THE NUMBER OF PLUMBING FIXTURES THAT ARE

EXISTING IN THE FIRST & SEOND FLOORS. THIS FIXTURE COUNT

IS INCLUDED IN THE TOTAL NUMBER OF FIXTURES PROVIDED.

2.THE HIGHER OCCUPANT NUMBER OF DESIGN VS. PROGRAM

LOAD WAS UTILIZED IN MAXIMUM OCCUPANT LOAD

CALCULATIONS ABOVE.

LEGEND

EXISTING SPACES TO REMAIN

EXISTING WALLS, STAIRS, & COLUMNS TO REMAIN

AREAS INCLUDED IN PHASE 3A PROJECT SCOPE

EXISTING DOOR & FRAME TO REMAIN

AREAS INCLUDED IN PHASE 3B PROJECT SCOPE

2.PROVIDE TEMPORARY WALL & DOOR IN PHASE 3A (AS

SHOWN ON PLAN). TEMPORARY DOOR 200 IS FOR

CONSTRUCTION ACCESS ONLY. GC TO PROVIDE DOOR

HARDWARE AND SIGN THAT AUTHORIZES ONLY

CONSTRUCTION PERSONNEL.

1.MAINTAIN EXISTING OCCUPANCIES IN AREAS THAT ARE NOT

IN SCOPE OF WORK.

NOTES:

CONCRETE INFILL (REFER TO STRUCT. DWGS)

4.DEMO TEMPORARY WALL IN PHASE 3B.

NEW DOOR IN EXISTING FRAME

NEW DOOR & FRAME

NEW ACCESS CONTROL DOORS

EXISTING ACCESS CONTROL DOORS

3.EXISTING DOOR IN LOBBY 123 TO REMAIN FOR STAFF

ENTRANCE DURING PHASE 3A CONSTRUCTION. ELEVATORS

ARE TO REMAIN IN OPERATION FOR ACCESS TO UPPER

FLOORS DURING PHASE 3A CONSTRUCTION.

4800 MEMORIAL DRIVE

WACO, TEXAS 76710

ARCHITECT/ ENGINEERS DRAWING TITLE: Project Title:

Location:

Date:

Project Number

Drawing Number

CONSULTANTS:

Date:

Building Number

PROJECT MANAGER:

CENTRAL TEXAS

VETERANS

HEALTHCARE

SYSTEM

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

1 2 3 4 5 6 87 9

F

E

D

C

B

A

97 8654321

F

E

D

C

B

A

Revisions:

TASK ORDER NO.

CODE PLAN, FIRST FLOOR - REFERENCE

ONLY

A0.03

HRC BASEMENT RENOVATION -

PHASE 3A & 3B

674A4-10-243

FEBRUARY 18, 2011

FEBRUARY 18, 2011

BID DOCUMENTS

1/8" = 1'-0"1

CODE PLAN, FIRST FLOOR -

REFERENCE ONLY

PLAN NORTHTRUE NORTH

AMENDMENT MAY 26, 2011 (REPLACES FEBRUARY 18, 2011) 05/ 26 /11

File details come from the government source that posted it. Updated .