This notice summarizes a solicitation for a federal contract opportunity. The Department of the Interior Bureau of Land Management is seeking proposals for construction activities to stabilize multiple areas located on the Pompeys Pillar National Monument Site. Work includes installation of geotechnical instrumentation, rockbolts, anchors, micropiles, and cement-based mortars. It also involves selective removal of vegetation, scaling of rock surfaces, installation of shotcrete and structural steel, and construction of drainage controls. The estimated price range for this acquisition is between $1,000,000 to $5,000,000. The solicitation was issued via SAM.gov under the total small business set-aside program. Proposals are due by March 7, 2023 at BLM's Montana State Office. The government anticipates awarding a firm-fixed price contract by May 19, 2023, with work to commence within 10 days of award and be complete by October 19, 2023.
View the file
Other files for this federal contract opportunity
Show all 24
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. INSTALLATION 4
1.1 Equipment 4
1.2 Description (Gateway overview) 5
1.3 Gateway power system 7
1.3.1 Ethernet cable power (using PoE Injector) 7
1.3.2 External power supply 10
1.4 Enclosure mounting 11
1.5 Internet communication 14
1.5.1 SIM Card 14
1.5.2 Ethernet connection 15
2. CONFIGURATION 16
2.1 Gateway connection 16
2.1.1 Local management interface (USB) 16
2.1.2 Fast connection (3G/GPRS or Ethernet) 18
2.2 Setup menu 19
2.2.1 Networks 19
2.2.2 Status 22
2.2.2.1 Gateway status 22
2.2.2.2 Logs 25
2.2.3 Configuration 26
2.2.3.1 General 26
2.2.3.2 FTP client 26
2.2.3.3 Compacted CSV 28
2.2.3.4 ModBUS gateway (ModBUS TCP server) 30
2.2.3.5 Internet 32
2.2.3.6 GPRS/3G 37
2.2.3.7 Radio 39
2.2.3.8 Remote Access 41
2.2.3.9 Upload firmware 43
2.2.3.10 Delete All 44
2.2.3.11 Reboot 45
3. DATA VISUALIZATION AND RETRIEVAL 46
3.1 Data recovery directly from the NODE 46
3.2 Data retrieval and visualization from the gateway 47
3.2.1 Engineering units conversion 47
3.2.2 Data visualization from the gateway 49
3.2.3 Data retrieval from the gateway 50
3.2.4 Sending files by FTP 52
3.2.5 Last messages (API format) 53
4. REST API calls 54
5. RADIO 57
5.1 Loadsensing radio system introduction 57
5.2 Radio specifications 61
3G/GPRS modem settings 61
5.2.1 LS-G6-GW-868 62
6.2.2 LS-G6-GW-915 63
5.2.3 LS-G6-GW-923 65
5.3 Number of nodes, sampling rate and slot time 67
6. RESULTS OF SIGNAL COVERAGE TEST 70
7. CONTACT WORLDSENSING. 71
8. TROUBLESHOOTING REFERENCE TABLE 72
TABLES
Table 01: API Calls (Inventory). 52
Table 02: API Calls (Data). 53
Table 03: API Calls (Monitoring). 53
Table 04: LS-G6-GW-EUR: Radio settings details. 60
Table 05: LS-G6-GW-FCC: Radio settings details. 61
Table 06: LS-G6-GW-923: Radio settings details. 63
Table 07: Slot time table: VW, ANALOG TILT nodes. 66
Table 08: Slot time table: RST / SisGeo networks at digital node. 66
Table 09: Slot time table: MDT Smartlink networks at digital node. 67
Table 10: TroubleShooting: GPRS/3G connectivity. 70
Table 11: TroubleShooting: Ethernet connectivity. 71
Table 12: TroubleShooting: Data errors. 72
1. INSTALLATION
1.1 Equipment
The Worldsensing LS-G6-GW Gateway is shipped with the following accessories:
Antenna
Cable antenna
Power over Ethernet (PoE) injector for wired network interface
USB local administration interface
Mounting kit
Not included:
Data line surge protector
Antenna surge protector
1.2 Description (Gateway overview)
The LS-G6 Gateway is made of high-impact resistant polycarbonate, engineered to withstand harsh industrial and outdoor environments. It offers an excellent flammability rating, good UV and chemical resistance and is rated IP67.
We recommend setting up and configuring the gateway in an office environment rather than going through the startup procedure in an outdoor or industrial environment.
LS-G6 Gateway, with all the parts indicated
The LS-G6 Gateway has the following parts:
1. The casing
2. Cable gland for RJ45 PoE or DC power cable
3. N connector for the sensor network radio antenna
4. Pressure stabilizer to protect against condensation
5. Sensor network radio antenna with N connector
6. Mounting kit
7. PoE injector and power supply cable
The gateway casing can be opened with a flat-head screwdriver via the small holes on either side of the door. You will need to open the gateway to perform the initial installation and configuration procedure.
LS-G6 Gateway, with all the parts indicated
Note: PoE power supply should be installed inside a box or indoors since it is not waterproof.
1.3 Gateway power system
The gateway can be powered either by PoE (Power over Ethernet) or DC. Only one power source is needed. Nominal power consumption is about 3.2 W (270 mA at 12 V); peaks reach
3.84 W of consumption, while idle is 2.16 W. In any case, the device allows a 11-30 V functioning range.
1.3.1 Ethernet cable power (using PoE Injector)
PoE connection to the LS-G6-GW Gateway complies with the IEEE 802.11af standard. The device is provided with a PoE compatible internal power supply.
On the gateway side, the Ethernet cable (not included) must first be inserted into the case through the cable gland. This cable gland allows a 4 mm to 8 mm diameter cable. The cable must be unshielded and stripped and connected to the terminal blocks in the correct order, as shown in the image below
Ethernet cable connection scheme (Gateway side)
We recommended using wire terminators to ensure better contact between cable wires and the connection pad. We also recommended using a shielded Ethernet cable (STP cable) in order to avoid external interferences.
Detail of the connections for the Power through PoE
Note that when grounding the gateway, a suitable Ethernet cable (shielded, as shown in the following image) should be inserted through the cable gland. The shield of the cable must be clamped in the “earthing clip” to get good earth shielding, as depicted in the image below.
a) b)
a) Cross section of a shielded Ethernet cable; b) Detail of the power connection through PoE using a shielded Ethernet cable.
The other end of the Ethernet cable must be connected to the PoE injector through a standard, T568A/B specified Ethernet connector (RJ45).
It must be connected to the PoE injector port named “DATA AND POWER OUT”. The PoE injector must be connected to a power source.
The PoE injector may be replaced by a PoE powered switch port since the gateway does not require more than 48 V (the standard voltage provided by PoE switches).
Note: A suitable weatherproof Ethernet cable should be used if the gateway is to be placed outdoors (e.g. Ubiquiti TOUGHCable). Alternatively, a normal Ethernet cable may be used in combination with a protection tube.
Wiring of the cable at the RJ45 connector (following T-568A/B specifications) to be inserted in the PoE Injector
1.3.2 External power supply
The gateway can also be powered using direct current (DC) through an external power supply, which may vary between 11 and 30 V. This alternative method has been developed for installations in which PoE (Ethernet cabling) is not possible due to the facilities.
For example, external waterproof housing can be mounted with an AC cable input, and a
12V or 24V exit (AC/DC power supply), a battery, or a solar or thermal solar kit.
In such installations, the power cable connected from the external power supply is cabled to the “CC” connection pad shown in the image below, passing through the cable gland used for the Ethernet PoE connection. This means Ethernet and CC connections are not compatible.
Note: If the gateway is powered using a generator or a power source that may induce surges or spikes, a voltage stabilizer may be installed in the power input of the gateway.
DC power connector
The cable gland allows for an external cable diameter of 4 mm to 8 mm.
Note: Powering down the gateway takes some time. Therefore, even if the power is disconnected, the gateway may still be active.
1.4 Enclosure mounting
The gateway enclosure comes with a mounting kit designed for various configurations:
Pole mounting by U-bolt
Gateway mounted on a pole.
Wall mounting
Gateway mounted on a wall
Metallic strapping mounting (tube, pipe, flue)
Gateway mounted on a pole
The metallic mounting kit must be grounded for safety reasons.
The antenna must also be mounted in place on the mounting kit
Gateway antenna mounting
The supplied antenna cable must be connected to the gateway enclosure, as shown in the image below:
Connection of the antenna cable to the connector
Finally, the antenna cable must be strapped to the mounting kit to reduce accidental wear.
Fixing of the antenna cable
Note: Surge protection (for both Ethernet and power supply) is not provided with the gateway as it is with data loggers. However, if this kind of protection is desired, external devices may be used (LS-ACC-LPETH or LS-ACC-LPANT). Contact Worldsensing technical support for further information.
1.5 Internet communication
A SIM card or a wired Ethernet network (with Internet access) can be used to connect the
Gateway to the Internet, which is necessary for remote access and to communicate with a monitoring data server. In the second case, the gateway and stored data can also be managed on LAN environment (local network without Internet access).
1.5.1 SIM Card
If you wish to use the gateway with a GPRS/3G connection, you must insert the SIM card.
To insert a SIM card:
Open the gateway enclosure with a flat-head screwdriver.
Push the SIM extraction button with a small screwdriver or the point of a pen.
Place the SIM card in the tray, with the contacts facing out.
Place the tray back into the gateway.
SIM card slot. Extraction button indicated.
1.5.2 Ethernet connection
If you wish to connect the gateway to the Internet through an Ethernet cable, use the PoE injector.
The cabling between the gateway and the PoE injector is the same used for feeding the device (see point 1.3.1). To connect to a LAN network, you must connect a direct Ethernet cable from the “DATA IN” PoE injector port to the Local network (switch).
Note: The Ethernet cable should be connected before plugging in the PoE injector to
230VAC. Once the gateway is initialized, the Ethernet connection should be established in order to avoid problems with default Internet access configuration.
PoE. The left port (Data & Power Out) is for the power cable and the right port
(Data-In) is for data transmission to the network.
2. CONFIGURATION
Configuration is carried out with a desktop or laptop computer. The LS-G6 Gateway has a web interface for all configuration and data retrieval tasks. The interface is accessible through any of the gateway’s network connections, which will be explained in this section.
2.1 Gateway connection
Factory configuration has been deployed to communicate outside (Internet) without the need for any configuration. When connecting any two interfaces (3G/GPRS or Ethernet) and booting the gateway, it will automatically be configured to connect via the LAN network using DHCP settings, and if not available (no link to the network) it will switch to
3G/GPRS using the installed SIM card with default APN settings.
In any case, a wired network limited by security policies or lack of an Internet connection, will deny any internet connection. In this case local management interface access will be required. This makes configuration of the device possible in a local environment.
2.1.1 Local management interface (USB)
In order to connect to the gateway on-site without depending on an external network, you may use the local administration interface. This interface provides all the features of web administration, including network configuration and access to LS-G6 data.
In order to use the local administration interface, you must:
Open the gateway box with a flat-head screwdriver.
Connect the supplied USB Ethernet adapter to the USB port on the front plate of the gateway.
Connect an Ethernet cable from the gateway’s USB adapter to your laptop computer.
Ensure that your computer is configured to acquire an IP address automatically using DHCP.
Open the following website on your Internet browser:
http://169.254.0.1 user: admin password: VMjG6z
An SSL certification error will appear. This is normal as this gateway uses a self-signed certificate for SSL authentication. Add a security exception for this certificate to allow the connection. Check your browser’s documentation for instructions on how to do this.
Introduce the provided user and password.
Notes:
Should you experience difficulty connecting, check these steps:
Use the USB-to-Ethernet adapter provided by WorldSensing (other adapters may not work depending on the driver).
If the computer used to configure the gateway does not have an Ethernet port, use two USB-to-Ethernet adapters of the same model.
Check if the USB-to-Ethernet adapter associated network Interface has received a valid IP address (169.254.XXX.YYY with Subnet Mask 255.255.0.0). If not, manually set a valid IP address on the same network range. E.g.: IP address: 169.254.0.3 and
Subnet Mask 255.255.255.0. Default gateway and DNS are not required as it is a direct communication without Internet access.
Disable any other network interfaces enabled on the computer (Wi-Fi, secondary
Ethernet Port, etc.).
The local administration interface should be used for:
Initial configuration of a new gateway.
On-site data retrieval and configuration of a gateway without an internet connection.
In the case of a forgotten remote access password, the local administration interface has a fixed password, which cannot be changed.
2.1.2 Fast connection (3G/GPRS or Ethernet)
Due to factory configuration, the gateway launches a process during booting to connect to the Internet automatically through these steps:
1) When booting, the gateway automatically detects if there is Ethernet connection to a LAN network (link). In this case, the gateway requests network configuration from the DHCP server and attempts to go outside with the received settings.
2) If the network link isn’t detected, the gateway attempts to go outside via SIM Card.
3) If connection isn’t possible, the gateway will work in standalone mode without an
Internet connection.
This default setup may not be successful. In this case, USB interface connection is required for manual configuration. Unsuccessful default setup may be the result of the following:
The Ethernet cable has been connected after the gateway has been turned on. The test to check if there is LAN connection is done at the very beginning when the device is turned on. All Ethernet cabling must be wired before turning the Gateway on.
The SIM card does not have default configuration, so 3G/GPRS settings must be manually configured.
The network has no Internet access (only Ethernet connections).
The SIM card has not been registered, does not have DATA, or works in a non-compatible frequency with the internal 3G/GPRS modem of the gateway.
It is a 4G ONLY SIM card. 4G is not supported by LS-G6-GW Gateway.
Once connected to the Internet, the connection to the gateway is carried out by
Loadsensing servers. The gateways connected to the Internet create a secured tunnel to the device for remote management and maintenance. For this purpose, data traffic must be enabled through SSH port: TCP 22. In this case, access the Gateway through this URL:
https://loadsensing.wocs3.com/{GATEWAY_ID}
The ‘admin’ user has admin properties and the password is that provided by WorldSensing in the device datasheet. Unlike the local administration password (USB-Ethernet connection), this password may be modified in the Setup menu. A View_Only user may also be enabled.
Once the IP address is known (in the case of a fixed IP address), the gateway can also be accessed through this URL:
https://{GATEWAY_IP_ADDRESS}
In this case, the access credentials are the same. This method may always be used, but it is meant for cases in which the network does not provide internet access to the gateway or the TCP 22 port is closed.
2.2 Setup menu
2.2.1 Networks
The first page of the gateway’s Web Configuration Interface displays the network ID and three different menus: networks, status and configuration. If the network ID has been changed for a specific gateway (the same serial number), several networks will appear in this tab under different IDs. A personalized name may be given to the network under the feature “Name”. Finally, the number of both active and inactive data loggers is displayed in green or red according to their status (active/inactive).
When entering the network, several node features can be viewed: status, model, serial number. Serial and node ID coincide by default, but ID may be changed. On this page you may:
Download the compacted DAT/CSV files with the data collected by the network
(raw data or engineering units). (See section 2.6 for further information.)
View the signal coverage test map in which test results are geographically plotted.
See basic data logger information: status, ID, serial number, model.
Access all gateway configuration interface menus.
Visualize data sent from data loggers. Additionally, messages lost and received by the gateway are counted (under the Status tab). The green number indicates messages received, the red number corresponds to lost radio messages and the orange number to messages lost due to gateway power interruption.
Change the sampling rate of the data loggers remotely.*
*This feature requires gateway software version 1.7 or higher and data logger firmware version 2.15 or higher. Please contact Worldsensing for further information on firmware and software versions.
Home page of the gateway. This is the first page displayed in the Web Configuration
Interface.
Summary of data logger status and history of received/lost messages
Changing sampling rate remotely:
The sampling rate can be changed remotely for one or several data loggers.
It is important to set the definitive sampling rate from the gateway interface for all the nodes. This procedure confirms that communication is OK in both directions (gateway to node and vice versa) and decreases the compacted files delay, which is one hour by default. Any new node should also be configured in this way (otherwise the compacted file delay would once again be set to one hour).
When the check box to the left of the corresponding line is selected and “Change sampling rate” is applied, the new sampling rate option can be selected from a pop-up menu.
Once the process is completed and changes have been saved, a clock icon with the value of the new sampling rate next to it will appear in the ID column of the node.
Should it appear with an orange label, this means that the change has not yet been applied.
If the orange label disappears, this means that the change is effective.
While the orange label is active, the changes may be cancelled.
If you try to introduce an unsuitable sampling rate according to the slot times required for the network, a message will appear asking you to accept that he/she understands the risk.
By changing the sampling rate remotely, you allow the gateway to access information about when it is going to receive data from the sensors. The advantage of letting the gateway access this information is that the compacted files (including data from the entire network) can be closed and uploaded to the FTP as soon as the sampling of the entire network is completed.
More information at Data retrieval and monitoring
2.2.2 Status
In the status tab, you can view the gateway status and logs.
2.2.2.1 Gateway status
In the gateway status menu, the following information is displayed:
General information
Gateway serial number
Displays the hardware’s serial number. This value cannot be changed.
Gateway model
Displays the hardware model.
Firmware version
Displays the current firmware version. The gateway’s firmware can be updated remotely by Worldsensing Technical Support as long as the gateway has an Internet connection and remote access is working (see below). Version 1.14 allows local upgrading by file.
Date
Displays the current date, according to the gateway’s internal clock, always in UTC.
Uptime in minutes
Displays the time in minutes since the gateway was connected or rebooted.
Input voltage
Displays the voltage that powers the gateway. This reading has a precision of +/- 0.35 V.
Voltage history
Links to a CSV file that includes the historical records of voltage, every 15 minutes. This is not divided by months.
Application status
Network ID
Displays the current sensor radio network ID.
Internet connection (ping)
Indicates whether or not the gateway is able to connect to the
Loadsensing server in order to check for connection.
Review the “Internet configuration” section for more information on this check.
Status reporting
Indicates whether or not the gateway is able to send status reports to Worldsensing.
These reports are sent via HTTP (port 80) to loadsensing.wocs3.com and provide information on the gateway’s status to Worldsensing
Technical Support.
Remote access
Indicates whether or not the gateway is able to open a remote access connection to the Worldsensing server.
This service uses a TCP connection to loadsensing.wocs3.com, on port 22.
The remote access mechanism is used to:
Provide Loadsensing Remote Access Service, which allows remote access to the Web Configuration Interface.
Provide remote access capability to Worldsensing Technical
Support, which allows for remote support and remote updates of deployed gateways.
Network information
Displays the parameters of the currently active network configuration.
Selected interface
Displays Internet connection selected manually or by default.
Ethernet status, IP and Netmask
Displays the status of the Ethernet interface (up/down) and the current address if there is one.
GPRS/3G status and IP
Displays the status of the GPRS/3G interface (up/down) and the current address if there is one.
Default gateway and DNS servers
GPRS Modem Info (This information is provided by the carrier, it may not be shown)
Status
Indicates whether or not the current GPRS modem status is correct.
IMSI
Identification number of a given user in a cellular network.
Operator
Telecommunication operator used for the GPRS modem.
Roaming
Indicates whether or not roaming mode is activated.
Mode
Indicates the technology (algorithm) used in telecommunications to define the channels and bandwidth to be used (CDMA or WCDMA).
Signal
Indicates the signal coverage of the telecommunications operator in percentages.
LAC
Location area code, an identification number.
CI
Cell identity.
Gateway status page
2.2.2.2 Logs
On the “Logs” page, status actions are reported and you can select the logs to be displayed by date.
This tab provides information about system actions, (node erase, time update, geographical area change…) node irregularities (data logger out of date, etc.), unsuccessful actions, (FTP data upload failure, etc.) and regular actions carried out manually or automatically by the device (file overwriting on gateway memory, new data file creation, etc.).
Records are organized by two types:
INFO (event information)
ALERT (events that should not occur, normally due to a configuration error)
LOG messages
2.2.3 Configuration
The “Configuration” tab displays different gateway configuration options for three different areas: data retrieval, communication interfaces, and maintenance tasks.
2.2.3.1 General
The gateway has an internal clock configured in UTC used to register all sensor readings, events and possible incidents.
However, you can introduce a different time zone in the gateway software interface. By doing so, you will be able to retrieve and visualize the data in local time, thus simplifying monitoring tasks.
We recommended setting the time zone when connecting to the gateway for the first time in order to avoid any timestamp issues with CSV file generation.
2.2.3.2 FTP client
In the configuration tab, you can enable an FTP client to push data from the gateway automatically to the server every three minutes at most (for node CSV files only, depending on the sampling rate set from the gateway; compacted CSV files are pushed every 15 minutes). The most common use of this feature is automatically uploading data to a monitoring server to create and display reading charts.
These are the configurable features of the FTP client:
HOSTNAME: IP or URL of the FTP server where data are going to be uploaded
PORT NUMBER:TCP PORT. 21 by default. It can be changed according to FTP server configuration.
USERNAME & PASSWORD: User and password for login to the FTP server. An anonymous user is also available. (“Use anonymous FTP” must be checked to use an anonymous user, leaving User and Password in blank.)
PROTOCOL: FTP protocol to use. LS-G6-GW supports 3 different types:
FTP: Standard FTP server, without data encryption of communication. We do not recommended sending data through the Internet, except for controlled LAN environment servers or VPN connected networks.
FTPS: This option allows configuration of data upload to a secure FTP server. It requires an authentication certificate issued by a Certification Authority (CA) such as Thawte, Verisign, etc. All communication is encrypted using SSH protocol.
FTPS (ignoring self-signed certificates). This option allows configuration of the connection to a secure FTP server with self-signed certificates not issued by a
Certification Authority. This option eliminates the display of invalid certificate messages, which must be manually accepted, to allow automatic data upload. This method has the same security level as the FTPS.
FTP MODE: This may be configured in passive or extended passive mode, depending on server configuration. Should you have questions, contact the server administrator or IT department. Most servers are configured in passive mode.
OUTPUT: Select how node readings are to be uploaded to the FTP server. One file per reading can be generated at the server (Create unique file at every upload) or a line for each new reading sent can be added to an existing file (Append to end of file). This second method dumps the whole file again in the case of errors (unable to read the file to be overwritten stored in the server, file writing error, file unavailable, etc.).
TYPE OF FILE: In this area the files to be uploaded to the server are selected by clicking the appropriate checkbox. Checking a file type enables the Path to upload the file or data. You can set a full path by typing ‘/’, or a relative path (associated with the login user) by typing
‘./’ (most common configuration, as it saves the files in the folder assigned by the FTP server). Files can also be stored in specific folders inside the relative path. For example, Health files may be set at ./Health/, while customized files may be set in a different folder
./Customized_readings. All paths must be set without commas.
The file to FTP Server upload process is as follows:
The gateway checks the last file or data uploaded to the server.
It then uploads the latest data (Append to an existing file or creates a new file).
Should an error occur in the previous step, the reading file is uploaded again, or the full file from the beginning of the month (append mode) is uploaded.
When configuring the FTP client for the first time, the client should test server connection by uploading a test file and deleting it once the test is done. If this procedure is completed successfully, the web interface will show a configuration OK message.
A gateway with a stable connection using a SIM card uses about 150 MB per month for FTP data upload.
FTP client configuration tab
Check Data Visuali zation and Retrieval for more information.
2.2.3.3 Compacted CSV
This feature allows you to create a self-configured CSV file with the desired columns, customized header names, column order, etc. The default number of columns is 600 but can be upgraded up to 1000 for bigger networks.
Note: Changing from 600 to 1000 columns in a production environment modifies the
CSV file structure, which may corrupt data files if uploaded to the FTP server. We recommended closing the existing CSV file on the server (disable FTP client on the gateway and rename the current files on the FTP server) Then modify the column number (gateway reboot is required) and enable the FTP client again to start uploading the new 1000 column CSV file once more.
Once saved, a CSV file called “compacted-custom-readings-XXXX-current.dat” (XXXX being the network ID) is created. Every time a new compacted CSV file is created, the old one is saved with a variation of the suffix “current” by “yyyy-mm-changeX”. This file appears on the Networks main page, where the files to download are visible.
View of the tool to create a self-configured CSV file of network data
2.2.3.4 ModBUS gateway (ModBUS TCP server)
This feature gives access to the latest data received from Loadsensing nodes stored in the gateway, using ModBUS TCP protocol since Loadsensing Gateway acts as a ModBUS TCP server. It also provides several data such as Health files (Battery status, etc.).
Once configured, the gateway stores the last RAW reading received from each sensor connected to a data logger on ModBUS memory records available by using this protocol through port TCP:502.
When configuring the ModBUS server, ([Configuration]>[ModBUS Gateway]), a UNIT ID must be associated with each node (data logger or wireless tiltmeter). The gateway stores data from each node in the records associated to each UNIT ID.
The interface can also be configured to connect to this server (wired interface (Ethernet) or all of them (Ethernet + GPRS/3G)) and the message TimeOut. This last parameter should be associated to the sampling rate of the readings to avoid incorrect readings (data are stored on ModBUS records until the message TimeOut. Then they are erased. If a reading is done after TimeOut, and no new data have been received from data loggers, NULL data will be shown on ModBUS client.)
Once a reading is received and stored on ModBus records, it will be available until the defined message TimeOut. From then on, when attempting to read that record, an error value will be returned by the ModBUS TCP Server.
A ModBUS Records annex for each type of node can be found in WorldSensing Support documents
View of the Modbus Configuration tab of the gateway
2.2.3.5 Internet
In the configuration tab, you can also change Internet connection details. By default, these are set on automatic mode.
It is possible to select a custom NTP server (from a local network). A custom SMTP server can also be configured.
The gateway is factory-configured to communicate with the Internet as fast as possible: by connecting to the Ethernet using configuration provided by the DHCP server or, if Ethernet connection (link) is not detected, by connecting to a 3G/GPRS network using the SIM card with a default configuration (PIN number deactivated) and mobile network configuration settings stored in the internal database of the device.
Internet communication is available with this setup. However, this configuration is not the best. Once the gateway Internet connection type has been selected, the deployed interface should be selected to avoid future connection problems.
For example, in the case of a gateway with default Internet configuration and an Ethernet connected, the gateway discards the Ethernet connection and attempts to connect using
3G/GPRS interface should there be physical problems (broken or disconnected Ethernet cable, data switch turned off, etc.) when attempting to reboot the device during troubleshooting procedures.
View of the Internet configuration tab of the gateway (default configuration).
Network Watchdog
The Network Watchdog is the mechanism that checks whether the Internet connection is working properly.
This mechanism checks the Internet connection every minute by sending a ping request to loadsensing.wocs3.com.
If the gateway is unable to communicate with the server for 40 minutes, it will assume there is a problem with the connection, and reboot the gateway.
The Network Watchdog must be disabled if the gateway does not have an
Internet connection.
If the Network Watchdog is left enabled for a gateway with no
Internet connection, it will start a reboot cycle every 40 minutes.
This will lead to sensor data loss, as data entering during the reboot cycle will not be stored.
The Network Watchdog is enabled by default.
Network connection
Automatic (default)
In automatic mode, the network connection mode is automatically configured upon gateway startup.
It is the default configuration for a fast connection.
If a connected Ethernet cable is detected, an Ethernet connection with DHCP will be used.
An Ethernet cable is considered to be connected if there is some kind of network equipment (for example a router or a switch) on the other side of the cable. The PoE injector doesn’t count.
If no Ethernet cable connection is detected, the GPRS connection will be launched with its configured parameters.
Once the Internet connection method has been defined, we strongly recommend modifying this setup to avoid connection in production environments in case of reset, network failure, etc. Manual configuration should be selected and accordingly configured.
Manual Configuration.
Options for manual configuration
This setting overrides auto-detection and always launches a selected connection type.
GPRS/3G
This adjustment discards automatic network detection and always launches a GPRS or 3G connection with the settings configured in the [Configuration]>[GPRS/3G] area.
Ethernet interface is deactivated, but can be used for feeding the device with PoE injector.
Ethernet with DHCP
This setting overrides auto-detection and always launches an Ethernet connection, receiving configuration automatically through DHCP. (Dynamic IP)
This option is the easiest to configure for an Ethernet interface but it may not be ideal for connecting directly to the gateway as the IP address may vary. Usually DHCP servers provide a specific IP address for a configured time.
After a reset or once this time has ended, the provided IP address may vary, affecting any NAT or VPN Tunnel configuration. In this case, we recommend a static IP address.
Ethernet with Static IP
This setting overrides auto-detection and always launches an Ethernet connection.
In this mode, you need to manually set all parameters of network configuration:
IP address
Netmask
Default gateway
DNS servers
NTP server (to synchronize the gateway’s clock)
By default, the NTP server must be accessible through the Internet. In general, if the gateway is connected to the Internet, it is common to use an
NTP server.
Even in situations in which the gateway is not connected to the Internet, it is still common have a custom NTP server, which may be in a local server.
We recommend using the same NTP server for the gateway as that used for the data monitoring server (if applicable).
SMTP Server (e-mail sending server configuration)
The default option is to use an SMTP server through the Internet. Should the gateway not be connected to the Internet, this option would not be valid.
A custom SMTP server can be defined if the gateway is not connected to the Internet or if you choose to use a default mail account. However, monitoring e-mails are still required. A custom SMTP server can be placed in a local server.
In this case, the CUSTOM option must be selected and the e-mail account to be used must be configured:
IP address and TCP port of the server, e-mail account (the one that sends the e-mails), TLS/SSL encryption method (if applicable) and authentication (user, password).
SMTP configuration settings for a G-MAIL account
2.2.3.6 GPRS/3G
The GPRS/3G configuration tab contains some configuration parameters specific to this type of connection.
Settings for the configuration of the GPRS/3G connection.
This configuration is applied whenever a GPRS/3G connection is used, regardless of whether it was the result of an automatic or manual configuration in the Internet tab.
PIN setting
Off (default)
In this mode, the gateway will not attempt to unlock the SIM card.
If the SIM card is protected by a PIN code, the GPRS/3G connection will fail.
On
This setting allows you to enter the PIN code for a PIN-locked SIM card.
Be careful not to boot the gateway with a PIN-protected SIM card with the wrong PIN set here. The gateway will automatically attempt to unlock the SIM card, and exhaust the three possible attempts.
There is no way to enter the PUK code in the gateway. If your card gets PUK-locked, you will have to unlock it using a mobile terminal.
APN settings
APN Auto selection (default)
Every mobile operator must set a specific configuration for connection to its network.
The LS-G6 Gateway features a database of the correct configurations for hundreds of operators around the world. This setting will attempt to configure the connection automatically based on the SIM card that is inserted.
This setting may fail if your operator is not in the database or your configuration is non-standard.
Manual APN configuration
This setting allows manual input of the mobile operator configuration values.
Use this setting if auto-selection didn’t work, or if specific, non-standard configuration values are required.
2.2.3.7 Radio
This page allows you to configure the parameters for the Wireless Sensor Radio Network.
There are three different gateway models, according to the geographical areas in which they’ll be placed. In addition, depending on the country’s regulations, the radio configuration will be set specifically.
Note that for some countries, an advanced menu may be displayed. This refers to the possibility of choosing different channels through which data can be sent in each spreading factor. This is useful for projects with many (hundreds) data loggers sampling at a high rate. Some data loggers would be set at one group (and also one gateway) and some other nodes at a different frequency group (as well as a second gateway configured to this other group), thus preventing potential collisions.
Note: If you change the default configuration under advanced options, these settings must also be changed in the data logger or wireless sensor configuration. The network type, ID and password must be the same at both gateway and nodes. Otherwise, no radio communication will be available, and data will not be dumped into the gateway.
In order for the LS-G6 data loggers to connect to this gateway and send data, both the gateway and all participating data loggers must be configured with the same parameters.
Country and frequency (Network type)
Depends on the country and gateway type.
Depending on the network model, different channel groups, channels or specific spreading factors may be chosen.
It must match the exact configuration of the node (network model, channel group, and SF, if applicable).
Depending on the network model, channel groups, channel and specific SFs may be selected.
It must match the exact configuration of the node (network model, channel group, and SF, if applicable).
Network ID
A numeric identifier of the wireless sensor network.
Set by default to the serial number of the gateway.
It should only be changed when a gateway is replaced and you do not wish to reconfigure all data loggers in the network.
Network Password
This password is used to encrypt all data in transit on the Wireless Sensor
Network.
The default factory password is printed on the Gateway Information Sheet.
Once the password has been changed, there is no way to recover it. The password will have to be changed to a new one in the gateway as well as in all data loggers in the network.
Radio configuration tab, inside the gateway interface
Three different gateway models are available. Each includes different network models valid for different countries, since radio regulations are different. For more information check
RADIO.
2.2.3.8 Remote Access
This page allows you to change the password for remote access to the Web Configuration
Interface.
The new, or the initially provided, password is required to access the gateway either through the public network interface or through the Loadsensing Remote Access Service.
Be careful not to set weak passwords. Doing so makes your gateway accessible from anywhere on the public network or the Internet if you have an Internet connection.
In order to change the password from the public interface or from the Remote Access
Service, the previous password must be entered. This is not required if you are connected through the local administration interface.
The default factory password is printed on the Gateway Information Sheet. Once it has been changed, there is no way to recover it.
In case of a lost or forgotten remote access password, you must use the Local
Administration Interface to change it to a known one (section 2.1.1).
View only password
This view is designed to provide access to users that are only allowed to see the data collected in the network and are not allowed to change any of the configuration parameters. The “view only” user has to be defined by the administrator.
Remote tunnel
Gateway firmware version v.1.13 or higher allows deactivating the VPN tunnel between
WorldSensing servers and the gateway, which uses port TCP 22.
Deactivating this tunnel means:
Access is not available from https://loadsensing.wocs3.com. Connection is only available through the local IP address.
There is no possibility of remote check or support from WorldSensing technical team.
There is only remote access from Internet when the SIM card has a Public IP.
For 3G/GPRS interfaces, the Modem firewall will also be deactivated. Therefore, there may be huge data usage as the gateway may be exposed to external attacks.
(Firewall rules discard all incoming requests from 3G/GPRS interface except those coming from the VPN tunnel.)
Remote Access tab, inside the gateway interface
2.2.3.9 Upload firmware
This option allows you to upgrade the gateway locally by uploading firmware versions provided by the WorldSensing support department when internet access is not available.
This feature is available in version 1.14 or higher. For lower version gateways, this feature is only available after upgrading remotely to version 1.14.
This feature also allows you to add new radios to the gateway or radios existing in other gateway models.
Click the “Select file” button to select a file stored in your computer and then click the “Upload & install new firmware” button to start the upgrade. The gateway will check the uploaded file and display an error message if the file does not fit with a valid radio or firmware version (in the case of corrupted files or another file type selected by mistake).
2.2.3.10 Delete All
In order to delete all the data contained in the gateway (but not the entire configuration), you have to access the “Delete all data” tab and follow the instructions.
This option also erases the FTP client configuration, so this must be reviewed after the data have been erased.
This option also erases all the nodes and the networks. As the nodes communicate with the gateway again (Radio configuration isn’t erased), the configured network and the nodes appear once more and generate new data files.
If a node or network needs to be erased (if created by mistake), check API CALLS.
Delete all tab, inside the gateway interface
2.2.3.11 Reboot
After changing gateway configuration parameters, the gateway must be rebooted to apply the changes. The gateway will inform you about this requirement.
Reboot tab, inside the gateway interface
Occasionally, the gateway may undergo a WEB connection. A call will first reboot the device and then it will attempt to connect.
https://loadsensing.wocs3.com/{GW_ID}/reboot.html
Resetting the Gateway may take several minutes depending on the Firmware version and device configuration.
3. DATA VISUALIZATION AND RETRIEVAL
This paragraph explains how data can be monitored, retrieved and received from the gateway.
The information generated by sensors connected to data loggers feed reading files in real time in the node. This information is stored when the sensor is activated and readings are sent to the data logger. This happens according to the configured sampling rate.
Depending on the radio configuration of the node network, data loggers and wireless sensors send the data to the gateway at the stipulated time intervals for each one (slot time). This means data are not available in real time but are delayed. The maximum delay to real-time data is this period, which is called SLOT TIME. (See RADIO section for more information.)
3.1 Data recovery directly from the NODE
Data are stored in data loggers in comma separated value files (CSV). These files are available to download using the Android DLog application.
For this purpose, an Android device must be connected to the Mini USB port node through a USB on the go (OTG) cable. When the DLog application loads, data can be downloaded by clicking on Download icon at [SENSORS DATA] tab. A Start and End date must be set, and data from that period will be downloaded. The android device will allow these CSV files to be opened with downloaded applications such as e-mail or cloud apps. Files are also stored on the device memory, in the DLog folder.
DLog application: Readings dump to the Android device
3.2 Data retrieval and visualization from the gateway
Data (readings and Health information) are sent to the gateway from the nodes, where they can be either visualized or retrieved. The device has an 8 GB internal memory, which allows network data to be stored for years. Depending on the configured sampling rate and the network size, it can store data for up to 10 years.
3.2.1 Engineering units conversion
It is possible to visualize the data received from each node, both raw and transformed into engineering units. This information is displayed on the Web interface.
In the second case, the gateway transforms the received RAW data into engineering units.
For this purpose, the variables and parameters required for each sensor must be configured. Depending on the type of sensor, these parameters may vary. The gateway always offers default configuration (showing the associated polynomial function), fields to add variable values, such as units, and maximum accepted readings.
Engineering units for each sensor must be activated and configured in the “Networks” tab by selecting the node of the network and clicking on the gear icon beside the last readings
(Last readings and time series Graphs tab). This option enables the menu where the settings associated to the sensor can be edited.
The polynomial function is displayed when selecting measure from the menu. The unit to be shown is also indicated.
In the “Last readings” tab, a gear icon appears on the right to edit the formula of the sensor.
Menu to edit the formula for transforming raw sensor data into engineering units.
3.2.2 Data visualization from the gateway
The gateway displays the latest sensor readings in both text and graph formats. To access these displays, you must click on the “Networks” tab and select the sensor node.
Readings are displayed in the paragraph [Last readings and Time series Graphs] where all the RAW readings are shown, as well as the readings converted into engineering units, if this function has been configured.
This paragraph shows the last reading of each connected sensor. If the graph icon of the header is selected, a chart with the data associated to the selected column will be shown.
The chart displays a maximum of 400 readings on a timeline. Sensors connected to that node can be shown or hidden, and the timeline can be modified.
Note: It is important to configure the correct time zone in [CONFIGURATION]>[GENERAL] so that the chart will be shown in real time. If the correct time zone is not configured, readings will be shown in UTC, the default configuration.
Circled in red, the icon to display the charts of each of the sensors.
3.2.3 Data retrieval from the gateway
Data received are stored in CSV files, which can be downloaded from the device web interface.
Each node sends the generated data (readings and Health information) through the radio network connection. This information is appended to the existing files or the gateway generates new files to store this information if the appropriate file does not exist.
Files are generated with the name XXXXX-current and in CSV format (for node readings files) or DAT format (for Gateway generated files). At the end of the month, the file is closed and renamed as XXXXX-yyyy-mm (where yyyy represents the current year and mm the current month) and a new empty current file is generated.
In both cases (node and gateway files), the current and previous month files are displayed and all existing older files are available in ZIP compressed format. This means historical information can be recovered (one file per month) unlike with the node, where a start and end date are required to generate and download the file.
These are the different type of files, depending on the information they store:
NODE FILES: These are the files generated with the information received from the node.
One file is generated per node connected to the network. They are available in the
“Networks” tab by clicking on the network, and then the node. These files are updated every time a node communicates with the gateway, so the most immediate information available on the gateway is stored here.
[Node_ID]-health-current.csv: Contains information related to the node. Battery status (in volts), Node temperature (in º C degrees) and UpTime (time since last reset of the node, in seconds)
[Node_ID]-readings-current.csv: Contains the readings in RAW of each sensor, and if configured, also in engineering units.
GATEWAY FILES (COMPACTED): The gateway periodically generates compacted files with the information received by all the nodes. This information is stored in the same way node information is stored. However, unlike with node information, it waits for a period of time
(slot time) to retrieve new information available from each node and append it. These files are available in the “Networks” tab by clicking the radio. These are the files:
compacted-readings-[Network_ID]-current.dat: Contains all the readings of all the nodes connected to the network in RAW format.
compacted-eng-[Network_ID]-current.dat: The same as above, but in this case displays the engineering units.
compacted-custom-readings-[Network_ID]-current.dat: Displays data from the selected sensors in RAW or engineering units. Previous configuration of this file is required. It can be configured in [Configuration]>[Compacted CSV].
Data displayed in compacted files are delayed one hour with respect to the existing node files. The reason for this delay is to prevent conflicts between recently received data and old data. When a compacted file is being generated, it is possible that not all of the information has arrived to the gateway yet, which could generate empty slots in compacted files.
This one hour delay is a default parameter. Changing the sampling rate from the gateway instead of the node may decrease this delay up to the Slot time, so the compacted information will be that received in the previous slot time.
Bear in mind that current files are designed to support up to 1000 columns and 600 by default.