Attachment 4 Manufactured Home First Article Inspection Checklist 2-11-20 First Article Inspection DRAFT NOT FINAL.xlsx
XLSX spreadsheet 205 KB Posted
- Attached to
- DRAFT SOLICITATION: DHS FEMA Manufactured Housing Units (MHUs) Federal contract opportunity
- Solicitation number
- Not on record
- Issued by
- Federal Emergency Management Agency
About this file
This draft solicitation from the Federal Emergency Management Agency seeks to award multiple indefinite delivery, indefinite quantity contracts for manufactured housing units to meet disaster housing needs under Section 408 of the Robert T. Stafford Act. Interested offerors are encouraged to provide questions on the draft solicitation and attachments by August 10, 2020 to help inform the agency's requirements. The solicitation will require housing units that meet commercial standards and comply with objectives for temporary disaster housing as defined by FEMA. The first article inspection checklist outlines acceptance criteria for exterior and interior components to ensure units meet specifications before use.
View the file
Other files for this federal contract opportunity
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
1. FEMA MHU Identification Number 2. Serial Number 3. Bar Code 4. HUD Number 5. Date of Inspection (MM/DD/YY)
| 6. Manufacturer Location | 7. Temperature and Climate Conditions | ||
| (Circle one of the icons) | 8. Unit Type (Circle one) |
F - Furnace
| B - Package System | 8F | |
| 8P | 14F - 1BR |
14F - 2BR
14F - 3BR 14B - 1BR
14B - 2BR
14B - 3BR
| 9. MHU Manufacturer Info | 10. Appliances | ||||||||||||||||
| Manufacturer: | Model: | Type | Manufacturer | Model | Serial Number | ||||||||||||
| Vendor: | Year: | Furnace | |||||||||||||||
| 11. Printed Name of Exterior Inspector | 12. Signature of Exterior Inspector | 13. Date (MM/DD/YY) | Air Conditioner | ||||||||||||||
| TPS | |||||||||||||||||
| 14. Printed Name of Interior Inspector | 15. Signatue of Interior Inspector | 16. Date (MM/DD/YY) | Refrigerator | ||||||||||||||
| Range | |||||||||||||||||
| 17. Type of Inspection: | First Article | Storage | Shipment | Water Heater | |||||||||||||
| 18. Final Acceptance Printed Name | 19. Final Acceptance Signature Name | 20. Recommendation: | |||||||||||||||
| Accept MHU | Reject MHU | ||||||||||||||||
| Exterior | |||||||||||||||||
| Line Item | Inspection Item Description | Pass | Fail | Line Item | Description of Failure | ||||||||||||
| 21 | Tires - Free from cracks, cuts, gouges, bumps or any tread separtation. No tire belts or plys exposed. | Enter Line item number and a brief description of failure. Circle location of failure on corresponding diagram on page 3 of 3. | |||||||||||||||
| 22 | Rims - Same color, do not have any gouges or cracks. Axle drums do not have any missing threaded studs or nuts. | ||||||||||||||||
| 23 | Axles, Springs, Spring Hangers - Free from damage. | ||||||||||||||||
| 24 | Main I-Beams - Not buckled, bent or twisted. | ||||||||||||||||
| 25 | Cross Members and Outriggers - Not buckled, bent or twisted. | ||||||||||||||||
| 26 | Hitch, Coupler and Jack - Free from damage. | ||||||||||||||||
| 27 | Frame - All exposed surfaces are painted and no rust. | ||||||||||||||||
| 28 | Drawbar - Painted Green. | ||||||||||||||||
| 29 | Brake axle wiring harness - No exposed wires and can be reconnected to another towing vehicle. | ||||||||||||||||
| 30 | Bottom board - Free from tears and/or rips. Patches are secure. No exposed insulation. | ||||||||||||||||
| 31 | Bottom board tire blowout protection - Free from damage. | ||||||||||||||||
| 32 | HUD Label - Present on road side of MHU. | ||||||||||||||||
| 33 | Vendor serial number - Legible on front header and stenciled on hitch. | ||||||||||||||||
| 34 | 8 Wide Express - Battery Box mounted to hitch assembly with battery. Battery shows no signs of leakage. | ||||||||||||||||
| 35 | Furnace only - Protective pipe friction fitted into header. A/C lines & electrical conduit for exterior A/C show no wear or rubbing. | ||||||||||||||||
| 36 | Furnace only - A/C condensor Hold down clips, vibration damping pad & protective cover with no visable wear or rubbing. | ||||||||||||||||
| 37 | Vinyl siding and trim - Buckled, cracked, bowed or missing. | ||||||||||||||||
| 38 | Vinyl siding wind protection strips - Present & free from damage. | ||||||||||||||||
| 39 | Windows and Doors - Damaged, cracked glass, bowed or missing parts or trim. | ||||||||||||||||
| 40 | Shingles - Missing, cracked or exposed fasteners. | ||||||||||||||||
| 41 | Wind diverters and plastic wrap - Present & free from damage | ||||||||||||||||
| 42 | |||||||||||||||||
| 43 | |||||||||||||||||
| 44 | |||||||||||||||||
| Interior | |||||||||||||||||
| Line Item | Inspection Item Description | Kitchen | Bath #1 | Bath #2 | Hallway | Living Room | BR #1 | BR #2 | BR #3 | ||||||||
| P = Pass F = Fail | |||||||||||||||||
| 45 | Vinyl Flooring - Free from gouges, cuts, bumps or repair patches. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 46 | Wall Finish - Free from popped panels, gouges, cuts or visable damage. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 47 | Trim - All wall, window and door trim is caulked and free from damage. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 48 | Windows - Operate freely without binding and free from damage. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 49 | Doors - Operate freely and UFAS threshold not damaged or bowed up. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 50 | Ceiling Finish - Free from damage, not buckled, cracked, bowed, sagging, no separations, loose or poped panels. | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | |||
| 51 | Plumbing - Fixtures, visable piping, fixtings, connections and supports are free from damage. | P | F | P F | P F | ||||||||||||
| 52 | Appliances - Free from scratches, dents and visable damage. | P | F | ||||||||||||||
| 53 | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | ||||
| 54 | P | F | P F | P F | P F | P | F | P | F | P | F | P | F | ||||
| 55 | P | F | P F | P F | P F | P | F | P | F | P | F | P | F |
| Line Item | Inspection Item Description | Pass | Fail | Line Item | Description of Failure |
| 56 | MHU entry keys - 3 sets of keys (Total of 6 keys) in kitchen drawer with ID tags (MHU Bar code on one side / MHU Serial number on other side. | Enter Line item number and a brief description of failure. Circle location of failure on corresponding diagram on page 3 of 3. | |||
| 57 | Microwave - Microwave in MHU Bedeoom 1 closet. | ||||
| 58 | Mini-blinds - Full length mini-blinds at each window. | ||||
| 59 | Furniture - Account for all furniture as shown on Ship Loose drawing | ||||
| 60 | NOAA Radio's - 1 radio per bedroom. | ||||
| 61 | Window screens - 1 per each operable window |
(Stored under BR #1 bed).
| 62 | Bath Exhaust Fan Timer - One each bathroom. |
| 63 | Lever Handles - All interior doors have lever handles. |
| 64 | Shower rod and curtain - One each bathroom. |
| 65 | Sprinkle system tools and red storage box |
| 66 | Red sprinkler document storage box. |
| 67 | Electrical test - Operational and polarity |
| 68 | Water line air test - Water heater bypass valve in "off" position |
| 69 | Drain line test - Winterize after passing test. |
| 70 | |
| 71 | |
| 72 |
| Exterior Layouts and Elevations | Interior Layouts | |||
| Frame | 1. Circle general area where failure occurred that is documented on page 1. | | | ||
| 2. Add corresponding line item number next to circle | 8' Wide Express MHU | |||
| 1. Circle general area where failure occurred that is documented on page 2. | ||||
| 2. Add corresponding line item number next to circle |
Left Side (Curb Side)
Right Side (Street Side)
| 14' Wide MHU | |
| 1. Circle general area where failure occurred that is documented on page 2. | |
| 2. Add corresponding line item number next to circle |
Front Elevation Rear Elevation
Roof
1 Bedroom MHU Layout
2 Bedroom MHU Layout
3 Bedroom MHU Layout
&"Arial,Bold"&18FEMA First Article Inspection&"Arial,Regular"&16 &"-,Bold"&20&KFF0000DRAFT &G
&"-,Bold"&20&KFF0000DRAFT &P of &N
Sheet2
Sheet3 image1.png image10.JPG image2.svg image3.png image4.svg image5.png image6.svg image7.png image8.svg image9.JPG image11.jpeg
File details come from the government source that posted it. Updated .