This is a solicitation for the construction of a sidewalk, monument wall, and catch basin repair at Keesler Air Force Base. The work will be conducted as a HUBZone small business set-aside utilizing performance price trade-off procedures, with a NAICS code of 237310 and PSC of Y1LB. The magnitude of proposed construction is between $500,000 and $1,000,000, with a 120-day performance period after award. The solicitation package will be posted on SAM.gov on or around August 15th 2022, with a closing date of September 14th 2022. Interested parties must register in SAM to be eligible for award. Questions may be directed to Contracting Specialist TSgt Herndon or Contracting Officer Katie Fulford.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SET NO. BMA No. 22-3772
KEESLER AIR FORCE BASE
BILOXI, MISSISSIPPI
PREPARED FOR
FOR
C O N S T R U C T I O N P L A N S
J U L Y , 2 0 2 2
-3
K A
FB
D
IV
IS
IO
N
M O
N
UM
EN
T
S
IG
N
SHEET INDEX
LOCATION MAP
FI
LE
N
A M
E
DIVISION STREET
C -0
DESCRIPTION SHEET NO.
TITLE / LOCATION MAP / SHEET INDEX
SITE LOCATION
ENTRY SIGN PLAN
ENTRY SIGN DETAILS
GRADING PLAN
ELECTRICAL LEGEND & SITE PLAN
ENLARGED ELECTRICAL PLAN & DETAILS
C-001
C-101
C-121
C-122
C-131
E-100
E-101
BROWN, MITCHELL
& ALEXANDER, INC.
CONSULTING ENGINEERSPascagoula, MS 39567
(228)864-7612
3221 Market Street
131 Rue Magnolia Biloxi, MS 39530 (228)436-7612
401 Cowan Road, Suite A, Gulfport, MS 39507 (228)864-7612
MONUMENT SIGN
KEESLER A.F.B. , BILOXI, MS 39534
I-1
KEESLER
AIR FORCE
BASE
HIGHWAY 90
DIVISION ST.
FO
R
R
ES
T A
VE
LA
R
C H
ER
B
LV
D
BACK BAY OF BILOXI
C
AI
LL
AV
ET
S
T.
PROJECT
LOCATION
N.T.S.
MISSISSIPPI SOUND
S:
\3
KA
FB
D iv is io n
St re et S id ew al k an d
Fl ag s\ C
AD
\D
W G
\E nt ry S ig n
AutoCAD SHX Text N O R T H
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text 14208
AutoCAD SHX Text 7/14/22
BM #1
BM #2
K.A.F.B.
VISITOR
CENTER
C-101
SI
TE
L O
C A
TIO
N
BJS
1"=20'
\3772\3772 SITE
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
KA
FB
M
O N
UM
EN
T S
IG
N
BI
LO
XI
, M
IS
SI
SS
IP
PI
w w w .b m a e n g in e e rs .c o m
SHEET
REV BY
SEAL
BR
O
W N
, M
ITC
H
EL
L
A
LE
XA
N
D
ER
, I N
C
C O
N
SU
LT
IN
G E
N G
IN
EE
R S
DATE
P a sc a g o u la
M
S
(2 )8
-7
M a rk e t
S tr e e t
R u e
M a g n o lia B ilo xi
M
S
(2 )4
-7
C o w n
R o a d
Su ite
A
G u lfp o rt
M
S
(2 )8
-7
N O
R T
H
SCALE: 1"=10'
PROPOSED SIGN LOCATION
SEE SHEET C-121 FOR LAYOUT AND
SHEET C-122 FOR FOUNDATION DETAILS
N O
R T
H
SCALE: 1"=50'
PROPOSED
SIGN/ WALL LOCATIONS
PROPOSED SITE LIGHTING
(SEE ELECTRICAL)
5'
SIGN LOCATIONSITE LOCATION
PROPOSED SIGN LOCATION
(SEE SHEET C-122 FOR LAYOUT AND
SHEET C-501 FOR FOUNDATION DETAILS)
PROPOSED SITE LIGHTING
(SEE ELECTRICAL)
5'
PROPOSED 4" THICK
CONCRETE
5'
PROPOSED 4" THICK
CONCRETE
DIVISION STREET
DIVISION STREET
FO
R
R
ES
T A
VE
N
U E
℄ COLUMN
BACK OF CURB
℄ COLUMN
BACK OF CURB
PROPOSED SIDEWALK
(BY OTHERS)
DME
7/14/2022
AutoCAD SHX Text
UNITED STATES OF AMERICA
AutoCAD SHX Text
KEESLER AIR FORCE BASE
AutoCAD SHX Text T
AutoCAD SHX Text
XFMR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
UNITED STATES OF AMERICA
AutoCAD SHX Text
KEESLER AIR FORCE BASE
AutoCAD SHX Text T
AutoCAD SHX Text
XFMR
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
AutoCAD SHX Text
BM #1
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BM #2
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text 9.96
AutoCAD SHX Text 14.09
AutoCAD SHX Text
IRON ROD SET IN BLUE CAP
AutoCAD SHX Text
IRON ROD SET IN BLUE CAP
AutoCAD SHX Text N=328315.35
AutoCAD SHX Text E=961736.27
AutoCAD SHX Text N=328146.34
AutoCAD SHX Text E=961802.64
AutoCAD SHX Text X
AutoCAD SHX Text X
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text 14208
BRICK TO MATCH INSTALLATION REQUIREMENTS
EXISTING FENCE
PROPOSED SIGN WITH BRICK COLUMNS
(SEE SHEET C-122 FOR DETAILS)
30'
PROPOSED SIGN
WITH BRICK COLUMNS
PROPOSED SIGN WITH BRICK COLUMNS
(SEE SHEET C-122 FOR MORE SIGN DETAIL)
5' 5'
PROPOSED LIGHTS
(BY OTHERS)
PROPOSED 4" THICK CONC. PAVEMENTPROPOSED 4" THICK CONC. PAVEMENT
6'
10'
22°
22°
6'
10'
30'
COLUMN
COLUMN℄
COLUMN℄
COLUMN
℄COLUMN
COLUMN
C-121
BJS
1"=6'
DWG\3772 ENTRY SIGN
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
BI
LO
XI
M
IS
SI
SS
IP
PI
EN
TR
Y S
IG
N
P
LA
N w w w
.b m a e n g in e e rs
.c o m
SHEET
REV BY
SEAL
B R
O W
N
M
IT
C H
E
LL
A
LE
X
A N
D
ER
, I N
C
C O
N S U
L
TI
N G
E
G
IN
E E R
S
DATE
P a sc a g o u la
M
S
)8
-7
M a rk e t
S tr e e t
R g n o lia B ilo xi
M
S
(2 )4
-7
C o w a d
G u lfp o rt
M
S
(2 )8
-7
KA
FB
M O
N
UM
EN
T
S
IG
N
FRONT ELEVATION
N O R T H
SCALE: 1"=6'
PLAN VIEW
8' -6
DME
7/14/2022
AutoCAD SHX Text
EXISTING FENCE (TO REMAIN)
AutoCAD SHX Text
EXISTING ASPHALT ROADWAY
AutoCAD SHX Text Keesler Air Force Base
AutoCAD SHX Text
EXISTING FENCE ON CONC. MOW STRIP (TO REMAIN)
AutoCAD SHX Text
EXISTING SECURITY FENCE TO REMAIN
AutoCAD SHX Text
EXISTING BACK OF CURB
AutoCAD SHX Text
EXISTING BACK OF CURB
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
GRASS MEDIAN
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ASPHALT PAVEMENT
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text 14208
12'-2"
7' -2
SIGN & LETTERING DETAIL SIDE VIEW ELEVATION
SIGN FACE PAINTED TO MATCH
"DARK BRONZE" OR INSTALLATION
SPECIFIC COLOR
BRUSHED ALUMINUM TEXT
(HELVETICA NEUE -85 HEAVY)
3'-4"
3' -0
8"
SERVICE BRANCH SEAL
(HELVITACA NEUE - 95 BLACK)
6"
7"
4"
5"
4" 1'
-4
2"
6" SIGN PANEL MOUNTED TO WALL
7' -2
1'
-4
FOUNDATION
ELEV=10.50
2' -1
2'-1"1'-4"
2' -5
2"2'-1"
2"
2'-5"
2'-1"
4'-8"
1'-4"1'-4"
2'-5"
2'-1" 2"
2"
CMU BLOCK
BRICK PER K.A.F.B.
INSTALLATION
REQUIREMENTS
BRICK CAP
FILL CMU WITH 1800 PSI CONCRETE
#4 STEEL VERTICAL REBAR
CENTERED IN EACH CELL
1" MORTAR
BETWEEN CMU AND
BRICK LAYER
STUCCO
COLUMN DETAILS
BRICK CAP
8" DOWEL
#4 VERTICAL BAR IN EACH CELL
FILL CMU WITH 1800 PSI CONCRETE
1/4" MORTAR JOINTS
1" MORTAR BETWEEN CMU AND BRICK LAYER
#4 @ 6" O.C. EACH WAY
3000 PSI CONCRETE
1' -6
6"
COMPACTED
SUBGRADE TO 95%
MOD. PROCTOR
8' -3
3"
3000 PSI CONC. FOOTING
#4 STEEL VERTICAL REBAR
CMU BLOCK FILLED WITH 1800 PSI CONC.
1' -4
TWO (2) COAT STUCCO COATING
SYSTEM REQ'D COLOR TO MATCH
INSTALLATION REQUIREMENTS
TOP OF WALL ELEV. 18.50
6" 6"
TOP OF FOOTING ELEV=10.00
BRICK CAP
2"
WALL SECTIONS
8' -6
TOP OF FOOTING ELEV=10.00
3" C
LE
AR
3"
CLEAR
ELEV=10.50
4'-8"
1'-6"1'-6"
#4 VERTICAL BAR IN EACH CELL
ALTERNATE DIRECTION OF LEGS
FILL CMU WITH 1800 PSI CONCRETE
1/4" MORTAR JOINTS
STUCCO
#4 @ 6" O.C. EACH WAY
3000 PSI CONCRETE
1' -6
6"
COMPACTED
SUBGRADE TO 95%
MOD. PROCTOR
TOP OF FOOTING ELEV=10.00
3" C
LE
AR
3"
CLEAR
(TYP.)
4'-2"
STUCCO
4' -8
#4 VERTICAL BAR IN EACH CELL
ALTERNATE DIRECTION OF LEGS
FILL CMU WITH 1800 PSI CONCRETE
1/4" MORTAR JOINTS
CMU BLOCK
PROPOSED 4" THICK
CONC. PAVEMENTEXISTING
MOW
STRIP
C-122
BJS
1"=1'
DWG\3772 ENTRY SIGN
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
BI
LO
XI
M
IS
SI
SS
IP
PI
EN
TR
Y S
IG
N
D
ET
A
IL
S w w w
.b m a e n g in e e rs
.c o m
SHEET
REV BY
SEAL
B R
O W
N
M
IT
C H
E
LL
A
LE
X
A N
D
ER
, I N
C
C O
N S U
L
TI
E
G
IN
E E R
S
DATE
P a sc a g o u la
M
S
)8
-7
M a rk e t
S tr e e t
R g n o lia B ilo xi
M
S
(2 )4
-7
C o w a d
G u lfp o rt
M
S
(2 )8
-7
KA
FB
M O
N
UM
EN
T
S
IG
N
LAYOUT NOTES:
1. CONTRACTOR TO LAYOUT LIMITS OF SIGN/WALL AND REVIEW WITH BASE REPRESENTATIVE PRIOR TO
CONSTRUCTION. CONTRACTOR SHALL BE PREPARED TO MAKE MINOR ADJUSTMENTS TO LAYOUT.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR PANEL SIGN INCLUDING ALL COLORS AND LETTERING TO
FOR REVIEW AND APPROVAL.
CONSTRUCTION MATERIAL NOTES:
1. CONTRACTOR SHALL COMPACT FOUNDATION SUBGRADE TO 95% MODIFIED PROCTOR.
2. ALL CONCRETE SHALL USED IN FOUNDATION OR PAVING SHALL HAVE A MINIMUM STRENGTH OF 3000 PSI.
3. ALL REINFORCING STEEL SHALL BE GRADE 60.
4. ALL CMU BLOCKS SHALL BE 8” CMU BLOCKS MEETING REQUIREMENTS OF ASTM C90.
5. STUCCO SHALL BE A 2 PART SYSTEM AND MEETING THE MINIMUM REQUIREMENTS OF ASTM C926. THE BASE COAT SHALL BE A APPROX. 3/8” THICK AND THE FINISH COAT SHALL BE APPROX. 1/8” THICK.
6. STUCCO COLORS SHALL MATCH THE KAFB REQUIREMENTS AND SAMPLE COLORS SHALL BE SUBMITTED TO BASE
REPRESENTATIVES FOR REVIEW AND APPROVAL.
7/13/2022
DME
7/14/2022
AutoCAD SHX Text
KEESLER AIR FORCE BASE
AutoCAD SHX Text
DIVISION STREET GATE ENTRY SIGN DETAILS
AutoCAD SHX Text
SCALE: 1" = 1'
AutoCAD SHX Text Keesler Air Force Base
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text 14208
9.60
10.2 9.75
C-131
G
RA
D
IN
PL
N
DME
BJS
1"=10'
\3772\3772 SITE
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
KA
FB
M
O N
UM
EN
T S
IG
N
BI
LO
XI
, M
IS
SI
SS
IP
PI
w w w .b m a e n g in e e rs .c o m
SHEET
REV BY
SEAL
BR
O
W N
, M
ITC
H
EL
L
A
LE
XA
N
D
ER
, I N
C
C O
N
SU
LT
IN
G E
N G
IN
EE
R S
DATE
P a sc a g o u la
M
S
)8
-7
M a rk e t
S tr e e t
R g n o lia B ilo xi
M
S
(2 )4
-7
C o w a d
G u lfp o rt
M
S
(2 )8
-7
N O
R T
H
SCALE: 1"=10'
DIVISION STREET
7/14/2022
AutoCAD SHX Text
36" L.OAK
AutoCAD SHX Text
42" L.OAK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
36" L.OAK
AutoCAD SHX Text
42" L.OAK
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
AutoCAD SHX Text
BM #1
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
BM #2
AutoCAD SHX Text
ELEV.
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text 9.96
AutoCAD SHX Text 14.09
AutoCAD SHX Text
IRON ROD SET IN BLUE CAP
AutoCAD SHX Text
IRON ROD SET IN BLUE CAP
AutoCAD SHX Text N=328315.35
AutoCAD SHX Text E=961736.27
AutoCAD SHX Text N=328146.34
AutoCAD SHX Text E=961802.64
AutoCAD SHX Text
ENGINEER
AutoCAD SHX Text L
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text O
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text I
AutoCAD SHX Text P
AutoCAD SHX Text P
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text L
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text A
AutoCAD SHX Text B
AutoCAD SHX Text
AutoCAD SHX Text X
AutoCAD SHX Text A
AutoCAD SHX Text D
AutoCAD SHX Text 14208
FO
R
ES
T
AV
EN
U
E
UG
E
UG
E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E U
G E
U G
E
U G
E
UG
E
UG
E
U G
E
U G
E U
G E
U G
E U
G E
U G
E
U G
E
U G
E
U G
E
U G
E U
G E
U G
E
U G
E
UGE UGE UGE UGE UGE UGE
UGE
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UG
E
UGE
UG
E
UG
E
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
UGE
CONCRETE DRAINAGE DITCH
6" RCP
ASPHALT
PARKING
T
G
D
UGE
UGE
UGE
UGE
UGE
UGE
BM
BM5
BM6
FO
R
R
ES
T
AV
EN
U
E
BM #1
BM #2
PROPOSED SIDEWALK (BY
OTHERS)
K.A.F.B.
VISITOR
CENTER
LIGHTING
SWITCHGEAR
CONDUIT AND WIRE
EL
EC
TR
IC
A L
SP
EC
S, L
EG
EN
D
S
ITE
P
LA
N
E-100
ELECTRICAL CONSULTANTS, PLLC
14116 CUSTOMS BLVD., SUITE #111
GULFPORT, MISSISSIPPI 39503
228.822.8000
WEC PROJECT #: 22-BMA-06
JWH
GPW
7/14/2022
AS SHOWN
\3772\3772 SITE
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
KA
FB
M
O N
UM
EN
T S
IG
N
BI
LO
XI
, M
IS
SI
SS
IP
PI
w w w .b m a e n g in e e rs .c o m
SHEET
REV BY
SEAL
BR
O
W N
, M
ITC
H
EL
L
A
LE
XA
N
D
ER
, I N
C
C O
N
SU
LT
IN
G E
N G
IN
EE
R S
DATE
P a sc a g o u la
M
S
)8
-7 rk e t
S tr e e t g n o lia
B ilo xi
M S
(2
)4
-7
C w a d
G u lfp o rt M
S
(2
)8
-7
S
S
ID
I P
M IFO
ER
TS A T E
G
I SS S
P.
OG
YR W ORY
C
PI
K
E SS
GER
R
SI
ET
P FOR
I N
ED
O
LAENGINEER
15175
N O
R T
H
LUMINAIRE SCHEDULE
MARK LAMPS MOUNTING DESCRIPTION MANUFACTURER EQUALS
FL LED IN-GROUND LED, IN-GRADE MOUNTED FLOOD LIGHT, WALL WASHER BEGA 84618-K4 OR APPROVED EQUAL
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
XFMR
AutoCAD SHX Text T
AutoCAD SHX Text
6' CHAIN LINK FENCE
AutoCAD SHX Text G
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
XFMR
AutoCAD SHX Text
MB
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text
GEN. PAD
AutoCAD SHX Text W
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text Y
AutoCAD SHX Text D
AutoCAD SHX Text W
AutoCAD SHX Text H
AutoCAD SHX Text Y
AutoCAD SHX Text D
AutoCAD SHX Text W
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text
EXIST. SECURITY FENCE
AutoCAD SHX Text
EXISTING CURB & GUTTER
AutoCAD SHX Text J
AutoCAD SHX Text J
AutoCAD SHX Text
APPROXIMATE LOCATION OF EXISTING PANEL "SL"
AutoCAD SHX Text
EXISTING PULL BOX TO REMAIN
AutoCAD SHX Text
EXISTING LIGHTING CIRCUIT "SL-3" TO REMAIN
AutoCAD SHX Text EXISTING SITE LIGHTING STANDARDS TO REMAIN, TYPICAL. ALL CONNECTED TO CIRCUIT "SL-3"
AutoCAD SHX Text
NEW PULL BOX
AutoCAD SHX Text
AREA OF WORK SEE ENLARGED PLAN
AutoCAD SHX Text
EXISTING PANELBOARD TO REMAIN
AutoCAD SHX Text
SPECIAL ELECTRICAL CONNECTION
AutoCAD SHX Text
JUNCTION BOX
AutoCAD SHX Text
ELECTRICAL LEGEND
AutoCAD SHX Text
GROUND CONDUCTORS IN CONDUIT
AutoCAD SHX Text
CIRCUIT CONDUCTORS IN CONDUIT
AutoCAD SHX Text
CONDUIT BELOW GRADE
AutoCAD SHX Text
CONDUIT DOWN
AutoCAD SHX Text
CONDUIT UP
AutoCAD SHX Text
FLEXIBLE CONDUIT, SEALTITE AT WET LOCATIONS
AutoCAD SHX Text
MULTIPLE CIRCUIT CONDUCTORS IN CONDUIT
AutoCAD SHX Text
WITH NEUTRALS
AutoCAD SHX Text
CIRCUIT HOMERUN TO PANEL BOARD.
AutoCAD SHX Text
XX-XX
AutoCAD SHX Text
XX-XX DENOTES PANEL NAME AND CIRCUIT NUMBER
AutoCAD SHX Text
IN-GROUND FIXTURE - FLOOD LIGHT
AutoCAD SHX Text
EXISTING POLE AND POLE MOUNTED FIXTURE
AutoCAD SHX Text
CONTINUATION OF CONDUIT RUN
AutoCAD SHX Text J
AutoCAD SHX Text
IN-GROUND PULL BOX
AutoCAD SHX Text BASIC ELECTRICAL REQUIREMENTS 1. ALL ELECTRICAL WORK TO CONFORM TO CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODES, NATIONAL FIRE PROTECTION CODES, NATIONAL ALL ELECTRICAL WORK TO CONFORM TO CURRENT EDITIONS OF THE INTERNATIONAL BUILDING CODES, NATIONAL FIRE PROTECTION CODES, NATIONAL ELECTRICAL CODES, NATIONAL ELECTRICAL SAFETY CODES, AND OTHER APPLICABLE LOCAL, STATE, AND FEDERAL LAWS, ORDINANCES, AND REGULATIONS. WHERE DRAWINGS OR SPECIFICATIONS EXCEED CODE REQUIREMENTS, THE DRAWINGS AND SPECIFICATIONS SHALL GOVERN. NO WORK SHALL BE INSTALLED WHICH IS LESS THAN MINIMUM LEGAL STANDARDS. 2. ALL WORK PERFORMED UNDER THIS DIVISION SHALL BE INSPECTED AND APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION AND GOVERNMENT ALL WORK PERFORMED UNDER THIS DIVISION SHALL BE INSPECTED AND APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION AND GOVERNMENT REPRESENTATIVE OR CONTRACTING OFFICER. 3. CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING WORK. NO ADDITIONAL SCOPE WILL BE CONTRACTOR SHALL VISIT THE SITE AND BECOME FAMILIAR WITH EXISTING CONDITIONS PRIOR TO BIDDING WORK. NO ADDITIONAL SCOPE WILL BE AUTHORIZED DUE TO LACKING OF UNDERSTANDING ON EXISTING CONDITIONS. 4. CONTRACTOR SHALL VERIFY EXISTING UTILITIES AT THE SITE. CONTRACTOR SHALL VERIFY EXISTING UTILITIES AT THE SITE. 5. PROVIDE FOR ALL PERMITTING AND INSPECTIONS. INCLUDE PAYMENT OF ALL PERMIT AND INSPECTION FEES APPLICABLE THE WORK IN THIS DIVISION. PROVIDE FOR ALL PERMITTING AND INSPECTIONS. INCLUDE PAYMENT OF ALL PERMIT AND INSPECTION FEES APPLICABLE THE WORK IN THIS DIVISION. 6. PROVIDE ONE YEAR WARRANTY, RECORD (AS-BUILT) DRAWINGS, AND OPERATION/MAINTENANCE MANUALS ON ALL ELECTRICAL EQUIPMENT AND LIGHTING PROVIDE ONE YEAR WARRANTY, RECORD (AS-BUILT) DRAWINGS, AND OPERATION/MAINTENANCE MANUALS ON ALL ELECTRICAL EQUIPMENT AND LIGHTING INSTALLED AS PART OF THIS PROJECT. 7. DURING CONSTRUCTION, THE CONTRACTOR SHALL EXERCISE CARE AND TAKE APPROPRIATE PRECAUTIONARY MEASURES TO PREVENT ANY DAMAGE TO DURING CONSTRUCTION, THE CONTRACTOR SHALL EXERCISE CARE AND TAKE APPROPRIATE PRECAUTIONARY MEASURES TO PREVENT ANY DAMAGE TO THE EXISTING STRUCTURES, SIDEWALKS, UTILITIES, COMMUNICATIONS, ETC. DURING THE PROJECT. THE CONTRACTOR SHALL CORRECT ALL DAMAGE CAUSED BY OR DURING THE PROJECT. CONTRACTOR SHALL PROVIDE NOT LESS THAN (2) AND NOT MORE THAN (10) WORKING DAYS ADVANCE WRITTEN, ELECTRONIC, OR TELEPHONIC NOTICE OF THE COMMENCEMENT, EXTENT, LOCATION AND DURATION OF THE EXCAVATION WORK TO MISSISSIPPI ONE-CALL SYSTEM, INC. (1-800-227-6477) AND ANY NONMEMBERS OPERATOR(S) OF ANY UNDERGROUND UTILITY LINES OR UNDERGROUND FACILITIES IN AND NEAR THE EXCAVATION AREA, SO THAT MISSISSIPPI ONE-CALL SYSTEM, INC OPERATOR(S) AND ANY NON-MEMBER OPERATOR(S) MAY LOCATE AND MARK THE LOCATION OF UNDERGROUND UTILITY LINES AND UNDERGROUND FACILITIES IN THE EXCAVATION AREA. 8. PROVIDE FOR AND INSTALL TEMPORARY POWER AS REQUIRED. COORDINATE WITH OWNER OR UTILITY COMPANY FOR CONNECTIONS. ALL TEMPORARY PROVIDE FOR AND INSTALL TEMPORARY POWER AS REQUIRED. COORDINATE WITH OWNER OR UTILITY COMPANY FOR CONNECTIONS. ALL TEMPORARY POWER SHALL CONFORM TO OSHA STANDARDS AND ALL CODE REQUIREMENTS. 9. WORKERS POSSESSING THE SKILLS AND EXPERIENCE OBTAINED IN PERFORMING WORK OF SIMILAR SCOPE AND COMPLEXITY SHALL PERFORM THE WORKERS POSSESSING THE SKILLS AND EXPERIENCE OBTAINED IN PERFORMING WORK OF SIMILAR SCOPE AND COMPLEXITY SHALL PERFORM THE WORK OF THIS DIVISION. 10. FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND THE SIZE AND LOCATION OF EQUIPMENT IS INDICATED FOR PURPOSES OF CLEARNESS AND LEGIBILITY, DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC AND THE SIZE AND LOCATION OF EQUIPMENT IS INDICATED TO SCALE WHENEVER POSSIBLE. VERIFY CONDITIONS, DIMENSIONS, INDICATED EQUIPMENT SIZES, AND MANUFACTURER'S DATA AND INFORMATION AS NECESSARY TO INSTALL THE WORK OF THIS DIVISION. COORDINATE LOCATION AND LAYOUT WITH OTHER WORK. 11. DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION OF CONDUITS, NUMBER AND SIZE OF CONDUCTORS, AND DIAGRAMMATIC ROUTING OF DRAWINGS INDICATE REQUIRED SIZE AND POINTS OF TERMINATION OF CONDUITS, NUMBER AND SIZE OF CONDUCTORS, AND DIAGRAMMATIC ROUTING OF CONDUIT. INSTALL CONDUITS WITH MINIMUM NUMBER OF BENDS TO CONFORM TO STRUCTURE, AVOID OBSTRUCTIONS, PRESERVE HEADROOM, KEEP OPENINGS AND PASSAGEWAYS CLEAR, AND COMPLY WITH APPLICABLE CODE REQUIREMENTS. 12. COORDINATE ELECTRICAL WORK WITH ALL OTHER WORK. COORDINATE ELECTRICAL WORK WITH ALL OTHER WORK. 13. THE SCOPE OF THE ELECTRICAL WORK INCLUDES FURNISHING, INSTALLING TESTING AND WARRANTY OF ALL ELECTRICAL WORK AND COMPLETE THE SCOPE OF THE ELECTRICAL WORK INCLUDES FURNISHING, INSTALLING TESTING AND WARRANTY OF ALL ELECTRICAL WORK AND COMPLETE ELECTRICAL SYSTEMS SHOWN ON THE ELECTRICAL DRAWINGS AND SPECIFIED HEREIN. 14. THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ELECTRICAL SYSTEMS TO PROVIDE A COMPLETE PACKAGE AS INDICATED BY THE CONTRACT THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL ELECTRICAL SYSTEMS TO PROVIDE A COMPLETE PACKAGE AS INDICATED BY THE CONTRACT DOCUMENTS. THE DOCUMENTS ARE INTENDED TO PROVIDE AN OUTLINE FOR THE REQUIRED INSTALLATIONS. THE CONTRACTOR SHALL ULTIMATELY PROVIDE A COMPLETE AND OPERATIONAL SYSTEM AT THE CONCLUSION OF THE PROJECT. 15. DETAILS ARE PROVIDED AS THEY RELATE TO THE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS COMPONENTS, PARTS, DETAILS ARE PROVIDED AS THEY RELATE TO THE INSTALLATION. CONTRACTOR SHALL PROVIDE AND INSTALL ALL MISCELLANEOUS COMPONENTS, PARTS, MATERIALS, FASTENERS, SPLICES, AND ANY OTHER INCIDENTAL ITEMS NECESSARY TO PROVIDE A COMPLETE INSTALLATION. 16. ELECTRICAL CONNECTIONS INDICATED ON DRAWINGS SHALL INCLUDE WIRING, INSTALLATION, CONNECTION AND ADJUSTMENT. REQUIRED ELECTRICAL ELECTRICAL CONNECTIONS INDICATED ON DRAWINGS SHALL INCLUDE WIRING, INSTALLATION, CONNECTION AND ADJUSTMENT. REQUIRED ELECTRICAL CONNECTIONS SHALL BE PERFORMED FOR SUCH EQUIPMENT AND APPLIANCES. WORK SHALL INCLUDE FURNISHING AND INSTALLING SUITABLE CONDUIT, JUNCTION BOXES, AND WIRING NECESSARY FOR A COMPLETE ELECTRICAL INSTALLATION. 17. PROTECT MATERIALS AND EQUIPMENT FROM DAMAGE AND PROVIDE ADEQUATE AND PROPER STORAGE FACILITIES DURING PROGRESS OF THE WORK. PROTECT MATERIALS AND EQUIPMENT FROM DAMAGE AND PROVIDE ADEQUATE AND PROPER STORAGE FACILITIES DURING PROGRESS OF THE WORK. DAMAGED MATERIALS AND/OR EQUIPMENT SHALL BE REPLACED. REMOVE RUBBISH, DEBRIS AND WASTE MATERIALS AND LEGALLY DISPOSE OF OFF THE PROJECT SITE. 18. REMOVE GREASE AND OIL SPOTS WITH SOLVENT. SUCH SURFACES SHALL BE WIPED AND CORNERS AND CRACKS SCRAPED OUT. EXPOSED ROUGH REMOVE GREASE AND OIL SPOTS WITH SOLVENT. SUCH SURFACES SHALL BE WIPED AND CORNERS AND CRACKS SCRAPED OUT. EXPOSED ROUGH METAL SHALL BE SMOOTH, FREE OF SHARP EDGES, CAREFULLY STEEL BRUSHED TO REMOVE RUST AND OTHER SPOTS, AND LEFT IN PROPER CONDITION TO RECEIVE FINISH PAINTING. 19. ADVISE THE GENERAL CONTRACTOR AND CONTRACTING OFFICER BEFORE STARTING THE WORK OF THIS DIVISION. ADVISE THE GENERAL CONTRACTOR AND CONTRACTING OFFICER BEFORE STARTING THE WORK OF THIS DIVISION. 20. ALL CONDUITS SHALL BE CONCEALED BELOW GRADE. IF ABSOLUTELY REQUIRED, EXPOSED CONDUITS SHALL BE PAINTED TO MATCH THE SURFACES ALL CONDUITS SHALL BE CONCEALED BELOW GRADE. IF ABSOLUTELY REQUIRED, EXPOSED CONDUITS SHALL BE PAINTED TO MATCH THE SURFACES ADJACENT TO INSTALLATION. REFER TO PAINTING AND COATING SECTION OF SPECIFICATIONS. 21. VERIFY ALL DIMENSIONS AND CLEARANCES PRIOR TO ROUGH-IN. VERIFY ALL DIMENSIONS AND CLEARANCES PRIOR TO ROUGH-IN. 22. COORDINATE PHASING OF WORK WITH ALL DRAWINGS AND OTHER TRADES / DISCIPLINES FOR ELECTRICAL INSTALLATIONS. COORDINATE PHASING OF WORK WITH ALL DRAWINGS AND OTHER TRADES / DISCIPLINES FOR ELECTRICAL INSTALLATIONS. 23. NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF ANY PLAN DISCREPANCIES PRIOR TO PROCEEDING WITH ROUGH-IN OR TRIM OUT. NOTIFY THE CONTRACTING OFFICER IMMEDIATELY OF ANY PLAN DISCREPANCIES PRIOR TO PROCEEDING WITH ROUGH-IN OR TRIM OUT. 24. OWNER HAS FIRST RIGHT OF REFUSAL FOR DEMOLISHED MATERIALS. DEMOLISHED MATERIALS, IF APPLICABLE AND NOT BEING REUSED BY THE OWNER HAS FIRST RIGHT OF REFUSAL FOR DEMOLISHED MATERIALS. DEMOLISHED MATERIALS, IF APPLICABLE AND NOT BEING REUSED BY THE OWNER, SHALL BE REMOVED FROM BUILDINGS AND REMOVED FROM THE PROJECT SITE AS REQUIRED BY THE GENERAL CONTRACTOR.
AutoCAD SHX Text
ELECTRICAL GENERAL NOTES AND SPECIFICATIONS
AutoCAD SHX Text BASIC ELECTRICAL MATERIALS, BOXES, CONDUIT, WIRING, AND GROUNDING 1. POLYMER CONCRETE BOXES: POLYMER CONCRETE BOXES: a. POLYMER CONCRETE BOXES ARE TO BE MADE FROM AGGREGATES IN COMBINATION WITH POLYMER RESIN, COMBINED POLYMER CONCRETE BOXES ARE TO BE MADE FROM AGGREGATES IN COMBINATION WITH POLYMER RESIN, COMBINED AND PROCESSED BY MIXING, MOLDING, AND CURING, AND REINFORCED WITH FIBERGLASS. b. BOXES ARE TO BE HIGH STRENGTH, IMPACT RESISTANT, CORROSION RESISTANT, NONFLAMMABLE, AND NONCORROSIVE. BOXES ARE TO BE HIGH STRENGTH, IMPACT RESISTANT, CORROSION RESISTANT, NONFLAMMABLE, AND NONCORROSIVE. c. ENCLOSURES, BOXES AND COVERS ARE REQUIRED TO CONFORM TO ALL TEST PROVISIONS OF THE MOST CURRENT ENCLOSURES, BOXES AND COVERS ARE REQUIRED TO CONFORM TO ALL TEST PROVISIONS OF THE MOST CURRENT ANSI/SCTE 77 “SPECIFICATION FOR UNDERGROUND ENCLOSURE INTEGRITY” SPECIFICATION FOR UNDERGROUND ENCLOSURE INTEGRITY” d. ALL COMPONENTS IN AN ASSEMBLY (BOX & COVER) ARE MANUFACTURED USING MATCHED SURFACE TOOLING. ALL COMPONENTS IN AN ASSEMBLY (BOX & COVER) ARE MANUFACTURED USING MATCHED SURFACE TOOLING. e. COVERS SHALL BE MARKED AS "LIGHTING" AS REQUIRED. COVERS SHALL BE MARKED AS "LIGHTING" AS REQUIRED. f. BOTTOM OF BOX SHALL BE FILLED WITH 6" OF PEA GRAVEL. BOTTOM OF BOX SHALL BE FILLED WITH 6" OF PEA GRAVEL. 2. ALL CONDUIT UNDERGROUND TO BE PVC SCH. 40 OR HDPE ROLL PIPE FOR DIRECT BURIAL. ALL CONDUIT UNDERGROUND TO BE PVC SCH. 40 OR HDPE ROLL PIPE FOR DIRECT BURIAL. 3. ANY EXPOSED CONDUITS SHALL BE GALVANIZED RIGID TO 10 FEET ABOVE FINISHED FLOOR WHEN INSTALLED IN AREAS ANY EXPOSED CONDUITS SHALL BE GALVANIZED RIGID TO 10 FEET ABOVE FINISHED FLOOR WHEN INSTALLED IN AREAS SUSCEPTIBLE TO DAMAGE. 4. ALL WIRING SHALL BE COPPER, THHN/THWN, SIZED AS NOTED. ALL WIRING SHALL BE COPPER, THHN/THWN, SIZED AS NOTED. 5. ALL WIRING SHALL BE CONDUCTOR TYPE THHN OR THWN INSULATED WITH POLYVINYL CHLORIDE AND COVERED WITH A ALL WIRING SHALL BE CONDUCTOR TYPE THHN OR THWN INSULATED WITH POLYVINYL CHLORIDE AND COVERED WITH A PROTECTIVE SHEATH OF NYLON, RATED AT 600 VOLTS. WIRES SHALL BE LISTED BY UNDERWRITER'S LABORATORIES (UL) FOR INSTALLATION IN ACCORDANCE WITH ARTICLE 310 OF THE NATIONAL ELECTRICAL CODE (NEC). CONDUCTORS MAY BE SOLID OR STRANDED COPPER FOR 12 AWG AND SMALLER CONDUCTORS, AND STRANDED COPPER FOR 10 AWG AND LARGER CONDUCTORS. CONDUCTORS SHALL BE INSULATED WITH PVC AND SHEATHED WITH NYLON. 6. GROUNDING SHALL BE INSTALLED PER NEC SECTION 250. GROUNDING SHALL BE INSTALLED PER NEC SECTION 250. 7. SPLICE BLOCKS SHALL BE COMPLETELY INSULATED AND SIZED FOR CONDUCTORS AS NOTED. SPLICE BLOCKS SHALL BE COMPLETELY INSULATED AND SIZED FOR CONDUCTORS AS NOTED. 8. FUSE HOLDERS SHALL BE IN-LINE CONNECTION WITH FUSES AS NOTED. FUSE HOLDERS SHALL BE IN-LINE CONNECTION WITH FUSES AS NOTED. 9. SPLICE BLOCKS AND FUSE HOLDERS SHALL BE LISTED FOR USE IN-GROUND, WET LOCATION. SPLICE BLOCKS AND FUSE HOLDERS SHALL BE LISTED FOR USE IN-GROUND, WET LOCATION. 10. GROUNDING CONDUCTORS SHALL BE COPPER, #10 MINIMUM WITH GREEN INSULATION, UNLESS NOTED OTHERWISE. GROUNDING CONDUCTORS SHALL BE COPPER, #10 MINIMUM WITH GREEN INSULATION, UNLESS NOTED OTHERWISE. 11. PROVIDE SUBMITTALS PER THE CONTACT DOCUMENTS FOR CONDUIT, WIRING, SPLICE BLOCK, FUSE HOLDER, FUSES, AND PROVIDE SUBMITTALS PER THE CONTACT DOCUMENTS FOR CONDUIT, WIRING, SPLICE BLOCK, FUSE HOLDER, FUSES, AND IN-GROUND PULL BOXES.
AutoCAD SHX Text LIGHTING 1. LIGHT FIXTURES MODEL NUMBERS WERE DETERMINED AT THE TIME THIS SPECIFICATION WAS WRITTEN; MODEL NUMBERS MAY LIGHT FIXTURES MODEL NUMBERS WERE DETERMINED AT THE TIME THIS SPECIFICATION WAS WRITTEN; MODEL NUMBERS MAY NEED TO BE MODIFIED, OR MAY REQUIRE THE ADDITION OR DELETION OF OPTIONS TO FULLY MEET SPECIFICATION REQUIREMENTS. 2. DESIGN OF LIGHTING FIXTURES, ACCESSORIES, SUPPORTS, AND METHOD OF FIXTURE INSTALLATION SHALL COMPLY WITH DESIGN OF LIGHTING FIXTURES, ACCESSORIES, SUPPORTS, AND METHOD OF FIXTURE INSTALLATION SHALL COMPLY WITH REQUIREMENTS OF SIGN CONSTRUCTION AND ADJACENT GRADES WHICH FIXTURE IS INSTALLED. 3. PROVIDE ALL NECESSARY COMPONENTS TO INSTALL FIXTURES IN GROUND AS DETAILED. PROVIDE ALL NECESSARY COMPONENTS TO INSTALL FIXTURES IN GROUND AS DETAILED. 4. INSTALL FIXTURES LEVEL AND PLUMB ON CONCRETE BASE AS NOTED. INSTALL FIXTURES LEVEL AND PLUMB ON CONCRETE BASE AS NOTED. 5. COMPONENTS AND FIXTURES SHALL BE LISTED AND APPROVED FOR THE INTENDED APPLICATION BY UNDERWRITER'S COMPONENTS AND FIXTURES SHALL BE LISTED AND APPROVED FOR THE INTENDED APPLICATION BY UNDERWRITER'S LABORATORIES (UL), OR OTHER NATIONALLY RECOGNIZED TESTING LABORATORY (NRTL). 6. LIGHTING FIXTURES SHALL BE THE TYPE INDICATED ON DRAWINGS AND AS SPECIFIED. FIXTURES OF SAME TYPE SHALL BE OF LIGHTING FIXTURES SHALL BE THE TYPE INDICATED ON DRAWINGS AND AS SPECIFIED. FIXTURES OF SAME TYPE SHALL BE OF ONE MANUFACTURER. 7. LIGHTING FIXTURES SHALL BE MADE IN AMERICA. LIGHTING FIXTURES SHALL BE MADE IN AMERICA. 8. FIXTURES SHALL BE OF THE TYPES AND MANUFACTURERS DESCRIBED IN THE LUMINAIRE SCHEDULE OF THE DRAWINGS, WITH FIXTURES SHALL BE OF THE TYPES AND MANUFACTURERS DESCRIBED IN THE LUMINAIRE SCHEDULE OF THE DRAWINGS, WITH LAMPS, WATTAGE AND VOLTAGE AS INDICATED OR APPROVED EQUAL. SUBMIT TO CONTRACTING OFFICER FOR ANY SUBSTITUTION APPROVALS PRIOR TO PURCHASE AND INSTALLATION. 9. ALL FIXTURE SHALL BE HIGH EFFICIENCY, HAVE SUITABLE BALLASTS OR DRIVERS TO MATCH LAMP TYPES, AND BE RATED FOR ALL FIXTURE SHALL BE HIGH EFFICIENCY, HAVE SUITABLE BALLASTS OR DRIVERS TO MATCH LAMP TYPES, AND BE RATED FOR VOLTAGE BEING SUPPLIED. 10. ALL LAMPS SHALL BE AS NOTED ON DRAWINGS. PROVIDE LAMPS FOR ALL FIXTURES AS NOTED. ALL LAMPS SHALL BE AS NOTED ON DRAWINGS. PROVIDE LAMPS FOR ALL FIXTURES AS NOTED. 11. CHECK AND ADJUST FIXTURES FOR REQUIRED ILLUMINATION. REPLACE DEFECTIVE LAMPS AND BALLASTS. TEST AND ADJUST CHECK AND ADJUST FIXTURES FOR REQUIRED ILLUMINATION. REPLACE DEFECTIVE LAMPS AND BALLASTS. TEST AND ADJUST LIGHTING CONTROL EQUIPMENT FOR PROPER OPERATION. 12. PROVIDE SUBMITTALS PER THE CONTACT DOCUMENTS FOR LIGHTING FIXTURES AND INSTALLATION INSTRUCTIONS,PROVIDE SUBMITTALS PER THE CONTACT DOCUMENTS FOR LIGHTING FIXTURES AND INSTALLATION INSTRUCTIONS, AutoCAD SHX Text scale
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL SITE REFERENCE PLAN
AutoCAD SHX Text E100
AutoCAD SHX Text
AutoCAD SHX Text 1" = 60'-0"
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
FL
EN
LA
RG
ED
E
LE
C
TR
IC
A
L
PL
A N
D
ET
A
IL
S
E-101
ELECTRICAL CONSULTANTS, PLLC
14116 CUSTOMS BLVD., SUITE #111
GULFPORT, MISSISSIPPI 39503
228.822.8000
WEC PROJECT #: 22-BMA-06
JWH
GPW
7/14/2022
AS SHOWN
\3772\3772 SITE
CAD
ENG
DATE
SCALE
BMA#
FILE
D
IV
IS
IO
N S
TR
EE
T
KA
FB
M
O N
UM
EN
T S
IG
N
BI
LO
XI
, M
IS
SI
SS
IP
PI
w w w .b m a e n g in e e rs .c o m
SHEET
REV BY
SEAL
BR
O
W N
, M
ITC
H
EL
L
A
LE
XA
N
D
ER
, I N
C
C O
N
SU
LT
IN
G E
N G
IN
EE
R S
DATE
P a sc a g o u la
M
S
)8
-7 rk e t
S tr e e t g n o lia
B ilo xi
M S
(2
)4
-7
C w a d
G u lfp o rt M
S
(2
)8
-7
S
S
ID
I P
M IFO
ER
TS A T E
G
I SS S
P.
OG
YR W ORY
C
PI
K
E SS
GER
R
SI
ET
P FOR
I N
ED
O
LAENGINEER
15175
N O
R T
H
AutoCAD SHX Text G
AutoCAD SHX Text
PROPOSED SIDEWALK (BY OTHERS)
AutoCAD SHX Text
EXISTING CURB & GUTTER
AutoCAD SHX Text J
AutoCAD SHX Text e
AutoCAD SHX Text
EXISTING LIGHTING STANDARD
AutoCAD SHX Text EXISTING LIGHTING CIRCUIT, TYPICAL, WITH 2-#3, 1-#3G CONTROLLED THROUGH CONTACTOR AT PANEL "SL"
AutoCAD SHX Text
2-#8, 1-#10G IN 1"C. DIRECTIONAL BORE AT ROAD.
AutoCAD SHX Text
2-#8, 1-#10G IN 1"C. DIRECTIONAL BORE AT ROAD.
AutoCAD SHX Text
VERIFY EXISTING UTILITY LINE
AutoCAD SHX Text
EXISTING LIGHTING STANDARD
AutoCAD SHX Text e
AutoCAD SHX Text 18"x18" (MINIMUM) PULL BOX. SPLICE AND TAP EXISTING LIGHTING CIRCUIT AT NEW PULL BOX. INTERCEPT EXISTING CIRCUIT. PROVIDE AND INSTALL IN-LINE FUSES FOR EACH CONDUCTOR TO NEW LIGHTS.
AutoCAD SHX Text J
AutoCAD SHX Text 8"x8" (MINIMUM) PULL BOX. SPLICE AND TAP LIGHTING CIRCUIT AT NEW PULL BOX. COORDINATE BOX LOCATION IN THE FIELD.
AutoCAD SHX Text J
AutoCAD SHX Text 8"x8" (MINIMUM) PULL BOX. SPLICE AND TAP LIGHTING CIRCUIT AT NEW PULL BOX. COORDINATE BOX LOCATION IN THE FIELD.
AutoCAD SHX Text LUMINAIRE "FL" NOTES: 1. INSTALL LUMINAIRE ON 12" DIAMETER SONOTUBE INSTALL LUMINAIRE ON 12" DIAMETER SONOTUBE AS INDICATED. MOUNT FLUSH AND LEVEL. 2. THREADED ROD TO BE SIZED PER THREADED ROD TO BE SIZED PER MANUFACTURER'S RECOMMENDATION. VERIFY SIZE PRIOR TO ROUGH-IN AND PLACEMENT OF CONCRETE. 3. AIM LUMINAIRE AT MONUMENT SIGN AND MOUNT AIM LUMINAIRE AT MONUMENT SIGN AND MOUNT AT 18" IN FRONT OF SIGN. 4. VERIFY ALL ROUGH-IN AND MOUNTING VERIFY ALL ROUGH-IN AND MOUNTING REQUIREMENTS WITH MANUFACTURER. 5. PROVIDE AND INSTALL OPERABLE MOCK-UP PROVIDE AND INSTALL OPERABLE MOCK-UP FIXTURE FOR FIELD REVIEW PRIOR TO COMPLETE ROUGH-INS. 6. LIGHT FIXTURES SHALL BE MADE IN AMERICA.LIGHT FIXTURES SHALL BE MADE IN AMERICA.
AutoCAD SHX Text
1" PVC
AutoCAD SHX Text
3000 PSI CONC.
AutoCAD SHX Text
THREADED ROD
AutoCAD SHX Text
SONOTUBE
AutoCAD SHX Text
1" PVC
AutoCAD SHX Text 18"
AutoCAD SHX Text
LUMINAIRE "FL"
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
NOT REQUIRED AT LAST LIGHT
AutoCAD SHX Text
10AMP FUSE, TYPICAL
AutoCAD SHX Text
NEW 2-#8, 1-#10GND CONDUCTORS FOR EACH CIRCUIT TO SIGN LIGHT FIXTURES "FL"
AutoCAD SHX Text L1
AutoCAD SHX Text L2
AutoCAD SHX Text
GND
AutoCAD SHX Text
SPLICE BLOCK
AutoCAD SHX Text
EXISTING #3
AutoCAD SHX Text L1
AutoCAD SHX Text
AutoCAD SHX Text L1
AutoCAD SHX Text L2
AutoCAD SHX Text L2
AutoCAD SHX Text
GND
AutoCAD SHX Text
GND
AutoCAD SHX Text
GND
AutoCAD SHX Text L1
AutoCAD SHX Text L2
AutoCAD SHX Text
NEW 2-#8, 1-#10GND CONDUCTORS TO EXISTING STREET LIGHTS
AutoCAD SHX Text
AutoCAD SHX Text
10AMP FUSE, TYPICAL
AutoCAD SHX Text THE PROFESSIONAL ENGINEERING SERVICES PROVIDED BY BROWN, MITCHELL & ALEXANDER, INC.,(BMA) ARE RELATIVE TO THESE FINAL DRAWINGS AS SHOWN. ANY MODIFICATIONS TO THE DRAWINGS & ASSOCIATED SPECIFICATIONS AS PREPARED BY BMA WITHOUT THE WRITTEN CONSENT OF BMA, SHALL RELIEVE BMA OF ANY & ALL LIABILITY AS A RESULT OF ANY SUCH MODIFICATIONS.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 1"=10'
AutoCAD SHX Text 1"=20'
AutoCAD SHX Text 1"=30'
AutoCAD SHX Text 1"=40'
AutoCAD SHX Text 1"=50'
AutoCAD SHX Text 1"=60'
AutoCAD SHX Text 1"=100'
AutoCAD SHX Text 7/14/22
AutoCAD SHX Text scale
AutoCAD SHX Text
AutoCAD SHX Text
ENLARGED ELECTRICAL PLAN - MONUMENT SIGN
AutoCAD SHX Text E101
AutoCAD SHX Text
AutoCAD SHX Text 1/16" = 1'-0"
AutoCAD SHX Text scale
AutoCAD SHX Text
AutoCAD SHX Text
IN GROUND LUMINAIRE DETAIL
AutoCAD SHX Text E101
AutoCAD SHX Text
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text scale
AutoCAD SHX Text
AutoCAD SHX Text
LIGHTING CIRCUIT SPLICE DETAIL
AutoCAD SHX Text E101
AutoCAD SHX Text
NOT TO SCALE
| 3772-ENTRY SIGN-C-001 |
| Sheets and Views |
| C-001 |
| 3772-ENTRY SIGN-C-101 |
| Sheets and Views |
| C-101 |
| 3772-ENTRY SIGN-C-121 |
| Sheets and Views |
| C-121 |
| 3772-ENTRY SIGN-C-122 |
| Sheets and Views |
| C-122 |
| 3772-ENTRY SIGN-C-131 |
| Sheets and Views |
| C-131 |
| Electrical SIGNED |
| 22-BMA-06 EPLANS-E100.pdf |
| Sheets and Views |
| E100 |
| 22-BMA-06 EPLANS-E101.pdf |
| Sheets and Views |
| E101 |
File details come from the government source that posted it. Updated .