Attachment 4 - MAHG 251003_MSS.xls.xlsx

XLSX spreadsheet 27 KB Posted

Attached to
MAHG 25-1003 Repair Chiller 2
Solicitation number
FA301025R0009
Issued by

About this file

The file is a Material Submittals Schedule for a Department of the Air Force contract (Solicitation Number FA301025R0009) located at Keesler Air Force Base in Biloxi, Mississippi. The project involves repairing Chiller 2, replacing a remote starter, and upgrading Cooling Tower 2 in Building 4231, with a project value between $250,000 and $500,000. This is a HUBZone Small Business set-aside solicitation with a site visit scheduled for 10 April 2025 at 1pm CST.

The detailed Material Submittals Schedule outlines 21 specific submittal requirements, including mandatory documents such as HazMat questionnaires, MSDS forms, warranty documentation, inspection reports, and operational manuals. Key submission dates are primarily tied to the Notice to Proceed (NTP) or end of contract, with most technical reports required within 5-10 days of specific tests or inspections. Notable technical submittals include refrigerant analysis, compressor inspections, circuit leak tests, vibration analysis, and dynamic balance test reports. The government notes that funds are not currently available, and they reserve the right to cancel the solicitation before or after the closing date.

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Material Submittals Schedule

Project Number:
MAHG25-1003Project Title:
Repair Chiller 2, Replace Remote Starter, Cooling Tower 2 - B4231Solicitation / Contract Number:

Attachment 4 - FA301025R0009

Line Number(To be completed by Project Engineer)(To be completed by Contract Administrator)
Number of Copies Required (if not electronically submitted)Remarks
Item or Description of Item, Contract Reference, Type of SubmittalCertificate of ComplianceShop DrawingsSamplesColor SelectionManufacturer's RecommendationWarranty-Manufacturer and/or WorkmanshipCatalog DataOperating InstructionsSchedules, Listings, Reports, PlansTechnical DataTest ReportsField ReportsRequired Submission Date

fergusog: Enter the due date from the Contractor (MM/DD/YY) Date Received in Contracting fergusog: Enter the date received from the Contractor. (MM/DD/YY) Date to Civil Engineering fergusog: Enter the date submittal was given to CE for review. (MM/DD/YY) Return Suspense Date fergusog: Enter the date the submittal is due back from CE

(MM/DD/YY)

Submittal Numbers fergusog: Enter the Submittal Number

Date Contractor
NotifiedContractor Resubmittal

fergusog: Enter Resubmittal Number Final Approval fergusog: Enter the submittal final approval date

(MM/DD/YY)

Approved fergusog: Enter date the Contractor was notified of submittal approval

(MM/DD/YY)

fergusog: Enter Resubmittal Number Disapproved fergusog: Enter date the Contractor was notified of submittal disapproval

(MM/DD/YY)

fergusog: Enter the submittal final approval date

(MM/DD/YY)

1HazMat Questionnaire15 Days Prior to Start Date
2HazMat MSDS15 Days Prior to Start Date
3Hazmat Reporting Entry Form15 Days Prior to Start Date
4Hazmat Reporting Entry Form1End of Contract
5Recycling and Landfill Report1End of Contract
6Warranty (Manufacturer's)3End of Contract
71-Year Warranty (Contractor)1End of Contract
8Close Out Documents1111End of Contract
9Refrigerant, R123 as needed111110 Days from NTP
10Inspection, Assessment Findings and Required Repairs

Refrigerant Analysis Inspection of Compressor Inspection of Compressor Motor Inspection of Control Devices Inspection of ELEC PDs, wiring Inspection of Lube System

Inspection of Economizer, Liquid Lines11115 Days From Inspeciton
11Chiller/Compressor Refrigerant

Circuit

Vacuum Leak Test Report111115 Days From Test
12Chiller/Compressor Refrigerant

Circuit

Pressure, Leak Test Report111115 Days From Test
13Pressure & Temperature Differenttials of CHW, CW, and Refrigerant Report11115 Days From Test
14Eddy Current Test Report1115 Days From Test
15Compressor Dynamic Balance Test
Report111115 Days From Test
16Chiller Vibration Analysis,
Test Report111115 Days From Test
17Recovered refrigerant weight and amount1115 Days From Test
18Compressor motor serial number tags1End of Contract
19O and M Manuals1111End of ContractProvide 1 hard copy and 1 electronic copy
20Remote Starter111110 Days from NTP
21Cooling Tower111110 Days from NTP

&"Verdana,Bold"&12Schedule of Material Submittals &12Print on Legal size paper ( 8 x 14 ).

&P of &N