About this file
This document is a comprehensive set of mechanical, electrical, and lightning protection design drawings and specifications for tornado damage repairs at the USDA Agricultural Research Service's US Horticultural Research Laboratory in Fort Pierce, Florida.
The project includes five bid options covering renovation work across multiple greenhouse facilities and ancillary sites (Picos Farm and Leesburg Farm). Bid Option #2 involves mechanical system repairs to greenhouses 110-122 with natural gas piping installations and equipment connections. Bid Option #3 extends mechanical work to additional greenhouses (105-106, 111-112) with expanded piping systems. Bid Option #4 addresses a hoop house structure at Picos Farm with mechanical floor plans for heating and ventilation systems. Bid Option #5 covers greenhouse work at Leesburg Farm with similar mechanical provisions. The mechanical scope includes unit heaters, exhaust fans, evaporative cooling pads, air handling units, heat pumps, controls systems, and associated piping and ductwork. All work must comply with NEC, NFPA, and local codes with proper coordination between trades, gravity drainage priority, aluminum piping supports, and comprehensive as-built documentation requirements.
Electrical work encompasses new panelboards (ranging from 60A to 100A main breakers), branch circuits for greenhouse equipment (unit heaters, exhaust fans, lights), receptacles with GFI protection, access control systems for greenhouses 101-102, lighting fixtures (vapor-tight 4-foot LED strips with emergency battery packs), and a complete fire alarm system. Lighting plans include motion-sensor controls in corridors with automatic shutoff after 20 minutes, manual weatherproof switches for greenhouse control, and separate circuits per greenhouse per the detailed panel schedules provided. The electrical design also includes grounding, bonding to existing infrastructure, underground conduits at greenhouse sites, and water-tight junction boxes. Lightning protection per NFPA 780 requires air terminals on all greenhouse roof ridges bonded to copper clad ground rods with aluminum down conductors. The contract documents specify contractor responsibility for field verification, coordination with equipment manufacturers, phased demolition and construction per the provided phasing plan, and protection of existing systems throughout the project duration.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
SCREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
125 GREENHOUSE
AIR COND.
GREENHOUSE
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
STORAGE BUILDING
STORAGE BUILDING
GREENHOUSE
GREENHOUSE
116 GREENHOUSE
GREENHOUSE
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
HF
HF
HF
HF
HF
HF
HF
HF
ECP-1
ECP-1
ECP-1
EF-1 EF-1 EF-1 EF-1 EF-1 EF-1
EF-1 EF-1 EF-1
EF-1 EF-1 EF-1
EF-1
1" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
1" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
1" NATURAL GAS
PIPING
TYP. 1" ISOLATION
VALVE
ECP-1
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -10
3.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL PLAN
RENOVATION - BID OPTION #2
M-103 80 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
GENERAL NOTES
SCALE:
MECHANICAL PLAN: RENOVATION - BID OPTION #2
3/32"=1'-0"
M-103
1. ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, SYSTEMS, SUPPORTS, ETC.) MUST COMPLY WITH THE REQUIREMENTS OF ALL CODES, CODE AMENDMENTS, AND ORDINANCES AS USED, ADOPTED
AND/OR ENFORCED BY THE LOCAL JURISDICTION, COUNTY AND STATE.
2. ALL WORK IS TO BE FABRICATED AND/OR ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR
PROPER COORDINATION WITH WORK OF OTHER TRADES.
3. ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF THE WORK. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, OPTION, FITTING, OR COMPONENT. DO NOT SCALE DRAWINGS FOR
FABRICATION PURPOSES.
4. COORDINATE PLACEMENT OF ALL WORK WITH OTHER TRADES. DO NOT LOCATE, POSITION OR INSTALL ANY WORK IN SUCH A WAY THAT SYSTEM COMPONENTS OR ACCESS DOORS WILL BE INACCESSIBLE, UNUSABLE OR UN-MAINTAINABLE AFTER CONSTRUCTION IS COMPLETED.
5. GRAVITY DRAINAGE SYSTEMS HAVE PRIORITY WITH REGARD TO ROUTING. COORDINATE INSTALLATION OF WORK SO AS NOT TO INHIBIT THE INSTALLATION OR REQUIRED SLOPES FOR GRAVITY DRAINAGE
SYSTEMS.
6. ALL WORK MUST BE SUPPORTED FROM STRUCTURE ABOVE, FROM WALLS, OR FROM THE FLOOR UNLESS OTHERWISE INDICATED. DO NOT USE THE INSTALLED WORK OF OTHER TRADES FOR SUPPORT OR
BRACING. ALL PIPING SUPPORTS SHALL BE CONSTRUCTED OF ALUMINUM.
7. ALL LOW VOLTAGE WIRING FOR CONTROLS, ETC. SHALL BE INSTALLED IN CONDUIT. MATERIALS AND
INSTALLATION MUST COMPLY WITH NEC, NFPA, STATE AND LOCAL CODES AND ORDINANCES.
8. ALL PIPE PENETRATIONS THRU WALLS MUST BE PROVIDED WITH METAL SLEEVES OR THIMBLES.
SLEEVES AND THIMBLES SHALL BE AT LEAST 3/8 INCH LARGER THAN THE OUTSIDE DIAMETER OF THE PIPING PLUS INSULATION. CAULK BETWEEN SLEEVE AND PIPE WITH FLEXIBLE CAULKING MATERIAL
(RATED FOR SURFACE TEMPERATURE OF PIPE OR INSULATION) TO ALLOW MOVEMENT OF PIPE.
9. MAINTAIN MARKED AS-BUILTS THAT INDICATE FINAL ROUTING OF ALL VALVES, BELOW GRADE PIPING, ETC.
10. DEMOLITION AND NEW CONSTRUCTION SHALL BE PHASED IN ACCORDANCE WITH THE PHASING PLAN.
KEYPLAN
NTS
AREA OF WORK
LEGEND:
POINT OF CONNECTION
1" ISOLATION VALVE
N
SCALE: 3/32" = 1'-0"
16' 8' 0 16'
EXISTING 2" NATURAL
GAS PIPING
DAC-1
2" NATURAL GAS
PIPING
2" NATURAL GAS
PIPING
DAC-1
james harreld
SS042726
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
SCREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
125 GREENHOUSE
AIR COND.
GREENHOUSE
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
STORAGE BUILDING
STORAGE BUILDING
GREENHOUSE
110 GREENHOUSE
GREENHOUSE
SCREENHOUSE
104 GREENHOUSE
GREENHOUSE
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
UH-1
HF
HF
HF
HF
HF
HF
HF
HF
HF
HF
HF
HF
ECP-1
ECP-1 ECP-1
EF-1 EF-1 EF-1 EF-1 EF-1 EF-1
EF-1 EF-1 EF-1 EF-1 EF-1 EF-1EF-1 EF-1 EF-1
EF-1 EF-1 EF-1
EF-1
DAC-1
1" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
1" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
3/4" NATURAL GAS
PIPING
1" NATURAL GAS
PIPING
1" NATURAL GAS
PIPING
2" NATURAL GAS
PIPING
EF-1
ECP-1
ECP-1 ECP-1
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -10
4.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL PLAN
RENOVATION - BID OPTION #3
M-104 81 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
GENERAL NOTES
SCALE:
MECHANICAL PLAN: RENOVATION - BID OPTION #3
3/32"=1'-0"
M-104
1. ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, SYSTEMS, SUPPORTS, ETC.) MUST COMPLY WITH THE REQUIREMENTS OF ALL CODES, CODE AMENDMENTS, AND ORDINANCES AS USED, ADOPTED
AND/OR ENFORCED BY THE LOCAL JURISDICTION, COUNTY AND STATE.
2. ALL WORK IS TO BE FABRICATED AND/OR ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR
PROPER COORDINATION WITH WORK OF OTHER TRADES.
3. ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF THE WORK. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, OPTION, FITTING, OR COMPONENT. DO NOT SCALE DRAWINGS FOR
FABRICATION PURPOSES.
4. COORDINATE PLACEMENT OF ALL WORK WITH OTHER TRADES. DO NOT LOCATE, POSITION OR INSTALL ANY WORK IN SUCH A WAY THAT SYSTEM COMPONENTS OR ACCESS DOORS WILL BE INACCESSIBLE, UNUSABLE OR UN-MAINTAINABLE AFTER CONSTRUCTION IS COMPLETED.
5. GRAVITY DRAINAGE SYSTEMS HAVE PRIORITY WITH REGARD TO ROUTING. COORDINATE INSTALLATION OF WORK SO AS NOT TO INHIBIT THE INSTALLATION OR REQUIRED SLOPES FOR GRAVITY DRAINAGE
SYSTEMS.
6. ALL WORK MUST BE SUPPORTED FROM STRUCTURE ABOVE, FROM WALLS, OR FROM THE FLOOR UNLESS OTHERWISE INDICATED. DO NOT USE THE INSTALLED WORK OF OTHER TRADES FOR SUPPORT OR
BRACING. ALL PIPING SUPPORTS SHALL BE CONSTRUCTED OF ALUMINUM.
7. ALL LOW VOLTAGE WIRING FOR CONTROLS, ETC. SHALL BE INSTALLED IN CONDUIT. MATERIALS AND
INSTALLATION MUST COMPLY WITH NEC, NFPA, STATE AND LOCAL CODES AND ORDINANCES.
8. ALL PIPE PENETRATIONS THRU WALLS MUST BE PROVIDED WITH METAL SLEEVES OR THIMBLES.
SLEEVES AND THIMBLES SHALL BE AT LEAST 3/8 INCH LARGER THAN THE OUTSIDE DIAMETER OF THE PIPING PLUS INSULATION. CAULK BETWEEN SLEEVE AND PIPE WITH FLEXIBLE CAULKING MATERIAL
(RATED FOR SURFACE TEMPERATURE OF PIPE OR INSULATION) TO ALLOW MOVEMENT OF PIPE.
9. MAINTAIN MARKED AS-BUILTS THAT INDICATE FINAL ROUTING OF ALL VALVES, BELOW GRADE PIPING, ETC.
10. DEMOLITION AND NEW CONSTRUCTION SHALL BE PHASED IN ACCORDANCE WITH THE PHASING PLAN.
11. PROVIDE TEMPORARY GAS AND DOMESTIC WATER. UTILITY PATH IS SHOWN ON P-100.
KEYPLAN
NTS
AREA OF WORK
LEGEND:
POINT OF CONNECTION
1" ISOLATION VALVE
N
SCALE: 3/32" = 1'-0"
16' 8' 0 16'
UH-2
ECP-2
UH-2
EF-2 EF-2
HF
HF
DAC-1
GREENHOUSE GREENHOUSESCREENED
AREA
EF-2EF-2
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -10
5.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL PLAN
RENOVATION - BID OPTION #4
M-105 82 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
SCALE:
GREENHOUSE MECHANICAL PLAN
BID OPTION #4
1/4"=1'-0"
M-105
SCALE:
BID OPTION #4 MECHANICAL FLOOR PLAN HOOP HOUSE
1/4"=1'-0"
M-105
8'0 2' 4' 12'
SCALE: 1/4"= 1'-0"
GREENHOUSE
HOOP HOUSE
KEYPLAN - PICOS FARM SITE
NTS
ACCESSORY / STORAGE SPACE
UH-3
ECP-3 ECP-3
HF
3/4" GAS PIPING
EF-2 EF-2
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -10
6.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL PLAN
RENOVATION - BID OPTION #5
M-106 83 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
SCALE:
GREENHOUSE MECHANICAL PLAN
- BID OPTION #5
3/32"=1'-0"
M-106
SCALE: 3/32" = 1'-0"
16' 8' 0 16'
KEYPLAN
NTS
GREENHOUSES PESTICIDE BLDG
EXISTING CHILLER TO
REMAIN
EXISTING
CONDENSING
UNIT TO REMAIN
HP-1
AHU-1
AC-1
HP-4 HP-5
HP-3
HP-2
AHU-2
AHU-4 AHU-5
AHU-3
1 1
1 1
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
SCREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
GREENHOUSE
125 GREENHOUSE
AIR COND.
GREENHOUSE
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
AIR COND.
GREENHOUSE
STORAGE BUILDING
STORAGE BUILDING
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -40
1.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
ENLARGED MECHANICAL
M-401 84 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
SCALE:
ENLARGED MECHANICAL PLAN - BID OPTION #1
3/32"=1'-0"
M-401N
SCALE: 3/32" = 1'-0"
16' 8' 0 16'
AREA OF WORK
GENERAL NOTES
1. ALL WORK (MATERIALS, EQUIPMENT, DEVICES, COMPONENTS, SYSTEMS, SUPPORTS, ETC.) MUST COMPLY
WITH THE REQUIREMENTS OF ALL CODES, CODE AMENDMENTS, AND ORDINANCES AS USED, ADOPTED
AND/OR ENFORCED BY THE LOCAL JURISDICTION, COUNTY AND STATE.
2. ALL WORK SHALL BE FABRICATED AND/OR ERECTED USING CONTRACTOR'S FIELD MEASUREMENTS FOR
PROPER COORDINATION WITH WORK OF OTHER TRADES.
3. ALL CONTRACT DOCUMENTS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENTS OR GEOMETRICAL RELATIONSHIPS OF THE WORK. THEY ARE NOT INTENDED TO SPECIFY OR SHOW EVERY OFFSET, SEQUENCE, DEVICE, OPTION, FITTING, OR COMPONENT. DO NOT SCALE DRAWINGS FOR
FABRICATION PURPOSES.
4. COORDINATE PLACEMENT OF ALL WORK WITH OTHER TRADES. DO NOT LOCATE, POSITION OR INSTALL ANY WORK IN SUCH A WAY THAT SYSTEM COMPONENTS OR ACCESS DOORS WILL BE INACCESSIBLE, UNUSABLE OR UN-MAINTAINABLE AFTER CONSTRUCTION IS COMPLETED.
5. GRAVITY DRAINAGE SYSTEMS HAVE PRIORITY WITH REGARD TO ROUTING. COORDINATE INSTALLATION OF WORK SO AS NOT TO INHIBIT THE INSTALLATION OR REQUIRED SLOPES FOR GRAVITY DRAINAGE
SYSTEMS.
6. ALL WORK SHALL BE SUPPORTED FROM STRUCTURE ABOVE, FROM WALLS, OR FROM THE FLOOR UNLESS OTHERWISE INDICATED. DO NOT USE THE INSTALLED WORK OF OTHER TRADES FOR SUPPORT OR
BRACING. ALL PIPING SUPPORTS SHALL BE CONSTRUCTED OF ALUMINUM.
7. ALL LOW VOLTAGE WIRING FOR CONTROLS, ETC. SHALL BE INSTALLED IN CONDUIT. MATERIALS AND
INSTALLATION MUST COMPLY WITH NEC, NFPA, STATE AND LOCAL CODES AND ORDINANCES.
8. ALL PIPE PENETRATIONS THRU WALLS MUST BE PROVIDED WITH METAL SLEEVES OR THIMBLES.
SLEEVES AND THIMBLES SHALL BE AT LEAST 3/8 INCH LARGER THAN THE OUTSIDE DIAMETER OF THE PIPING PLUS INSULATION. CAULK BETWEEN SLEEVE AND PIPE WITH FLEXIBLE CAULKING MATERIAL
(RATED FOR SURFACE TEMPERATURE OF PIPE OR INSULATION) TO ALLOW MOVEMENT OF PIPE.
9. MAINTAIN MARKED AS-BUILTS THAT INDICATE FINAL ROUTING OF ALL VALVES, BELOW GRADE PIPING, ETC.
10. DEMOLITION AND NEW CONSTRUCTION SHALL BE PHASED IN ACCORDANCE WITH THE PHASING PLAN.
KEYED NOTES
1. PROVIDE AIR HANDLING UNIT MOUNTED FROM ABOVE. MOUNT UNIT AT THE SAME HEIGHT OF EXISTING
EQUIPMENT. RECONNECT TO EXISTING DUCTWORK AND CONDENSATE PIPING.
2. PROVIDE GROUND MOUNTED PACKAGED HEAT PUMP. RECONNECT TO EXISTING DUCT WORK.
PLAN- BID OPTION #1
UNIT HEATER SCHEDULE (EACH)
FAN
(HP)
UH-1 NATURAL GAS 2/3 SEE NOTES
REMARKSMARK TYPE INPUT
(BTUH)
75,000
VOLTAGE
120/1
AMPS
3.7
OUTPUT
(BTUH)
62,250
FAN
(CFM)
THERMAL
EFFICIENCY
83%
NOTES:
1. INTERGRATE WITH GREENHOUSE CONTROL SYSTEM.
2. PROVIDE WITH MOUNTING KIT.
3. EQUIPMENT SHALL COMPLY WITH THE "BUY AMERICAN ACT".
EVAPORATIVE COOLING PAD
MARK CONSTRUCTION TROUGH LENGTH GPM
ECP-1 ONE PIECE PVC 36' 68.3
REMARKSHEIGHT
4'
EAT
DB(°F) WB(°F)
95 78
LAT
DB(°F) WB(°F)
83 83
MEDIA
THICKNESS
6"
MAX. FACE
VELOCITY
125STAINLESS STEEL AND PVC
NOTES:
1. INTERLOCK ECP CONTROL WITH GREENHOUSE MASTER CONTROLLER.
2. INSTALL SYSTEM IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS.
3. PROVIDE WITH SUMP PUMP 110 VAC.
4. CONNECT TO ADJACENT DOMESTIC WATER LINE FOR MAKE UP WATER SUPPLY
SEE NOTES
GREENHOUSE FAN SCHEDULE
MARK MATERIAL DIAMETER TYPE RPM
EF-1 ALUMINUM 36" SIDEWALL PROP 10500 495 0.1"
AIRFLOW
(CFM)
E.S.P.
(IN W.G.) DRIVE
BELT
MOTOR
HP
1/2
VOLTS
PHASE
REMARKS
SEE NOTE 1,2,3
NOTES:
1. PROVIDE SINGLE-SPEED MOTOR.
2. PROVIDE WITH SLANT WALL HOUSING
3. PROVIDE WITH ALUMINUM BACKDRAFT SHUTTER.
EF-3 ALUMINUM 30" 5770 450 .1" BELT 1/4 208 3
UH-2 ELECTRIC 1/40 SEE NOTES10,200 208/3 8.310,200 380N/A
ECP-2 ONE PIECE PVC 22' 68.34' 95 78 83 83 6" 125STAINLESS STEEL AND PVC SEE NOTES
ECP-3 ONE PIECE PVC 6' 68.34' 95 78 83 83 6" 125STAINLESS STEEL AND PVC SEE NOTES
UH-3 PROPANE 2/3 SEE NOTES75,000 120/1 3.762,250 96183%
GREENHOUSE AIR CURTAIN SCHEDULE
MARK NOZZLE WIDTH AIR VOLUME POWER
DAC-1 111" 3500 CFM 1.5 KW 120 LBS
WEIGHT
MOTOR
HP
3 @ 1/2
VOLTS
PHASE
REMARKS
ALL
NOTES:
1. PROVIDE SINGLE-SPEED MOTOR.
2. PROVIDE WITH DOOR ACTIVATION.
NOZZLE VELOCITY
3,300 FPM
REMARKS
1. PROVIDE AND INSTALL REFRIGERANT SUPPLY AND RETURN LINES PER MANUFACTURER'S RECOMMENDATIONS.
HP-1 AIR-COOLED 46180 34476 15.2 95 230/3 18.1 30 251 ALL
MARK SYSTEM TYPE
COOLING
CAPACITY
(BTU/HR)
SENSIBLE
CAPACITY
(BTU/HR)
SEER
OUTDOOR
TEMPERATURE
(F)
VOLTS/
PHASE MCA MOCP WEIGHT
(LBS) REMARKS
HEAT PUMP SCHEDULE
REMARKS
1. AHU SHALL HAVE MERV 8 RATED FILTERS.
2. PROVIDE WITH THERMOSTAT BY UNIT MANUFACTURER.
AHU-1 HORIZONTAL DUCTED 1600 46184 34476 80 67 59.70 57.6 46170 70 86 170 230/1 9.0 15 ALL
TOTAL
(BTU/HR)
SENSIBLE
(BTU/HR)
EAT
(db °F)
EAT
(wb °F)
LAT
(db °F)
LAT
(wb °F)
TOTAL
(BTU/HR)
EAT
(db °F)
LAT
(db °F)
CAPACITY AIRSIDE CAPACITY AIRSIDE
VOLTS/
PHASE MCA MOCP
MARK UNIT TYPE AIRFLOW
(CFM)
COOLING HEATING
UNIT WT
(LBS)
ELECTRICAL DATA
REMARKS
AIR HANDLING UNIT SCHEDULE
HP-2 AIR-COOLED 56927 42229 14.30 95 230/3 28.2 35 251 ALL
HP-3 AIR-COOLED 23030 16647 16.00 95 230/1 13 20 174 ALL
HP-4
HP-5
AHU-2 HORIZONTAL DUCTED 1900 56927 42229 80 67 59.1 57.2 52500 70 86 170 230/1 9.0 15 ALL
AHU-3 HORIZONTAL DUCTED 700 23030 16647 80 67 57.6 56.1 22200 70 88 140 230/1 5.0 15 ALL
AHU-4
AIR-COOLED 46180 34476 15.2 95 230/3 18.1 30 251 ALL
AHU-5 HORIZONTAL DUCTED 1600 46184 34476 80 67 59.70 57.6 46170 70 86 170 230/1 9.0 15 ALL
AIR-COOLED 23030 16647 16.00 95 230/1 13 20 174 ALL
HORIZONTAL DUCTED 700 23030 16647 80 67 57.6 56.1 22200 70 88 140 230/1 5.0 15 ALL
PACKAGED UNIT SCHEDULE
SA
FLOW
(CFM)
ESP
(IN H2O)
TSP
(IN H2O)
FAN
SPEED
(RPM)
PACKAGED
MARK TYPE
1200AC-1
SUPPLY AIRFLOW DATA
2.0 2.5 1241
TOTAL
MBH
SENS
MBH EAT °F LAT °F
DX COOLING
CAPACITY AIR SIDE
36.8 25.5 90
EER
OPER.
WEIGHT
(LBS) REMARKS
FILTER
MERV 8 400 SEE NOTES
MCA
208/1
SEER2 VOLTS/
PHASEEAT °F
(DB/WB)
LAT °F
(DB/WB)
AIR SIDE
80/67 59.0/57.0
KW
ELECTRIC HEATING
CAPACITY
NOTES:
1. PROVIDE DOUBLE WALL CONSTRUCTION
2. PROVIDE WITH HORIZONTAL DISCHARGE.
3. PROVIDE WITH UNIT MICROPROCESSOR CONTROLLER CAPABLE OF STANDALONE OPERATION WITH INTEGRAL SCHEDULE AND OPERATIONS SETPOINTS (ADJ.). LOCATE MICROPROCESSOR CONTROL ADJACENT TO
THERMOSTAT.
4. PROVIDE BAROMETRIC RELIEF.
- 68
MOP
706011.27 11.0 13.8
REMARKS
1. AHU SHALL HAVE MERV 8 RATED FILTERS.
2. PROVIDE WITH THERMOSTAT BY UNIT MANUFACTURER.
WMU-1 WALL MOUNTED 1700 600 230/3 39 60 ALL
VOLTS/
PHASE MCA MOCP
MARK UNIT TYPE AIRFLOW
(CFM)
UNIT WT
(LBS)
ELECTRICAL DATA
REMARKS
PACKAGED WALL MOUNT UNIT SCHEDULE
VARIABLE
CAPACITY ECU
COMPRESSOR
TYPE
EER
67000
COOLING
CAPACITY
(BTU/HR)
EF-2 ALUMINUM 36" SIDEWALL PROP 10500 495 0.1" BELT 1/2 208 1 SEE NOTE 1,2,3
SEE NOTE 1,2,3
HF ALUMINUM 18" CEILING MOUNTED HORIZONTAL 2000 1100 NA DIRECT 1/15 115 1 SEE NOTE 1
SIDEWALL PROP
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -60
1.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL SCHEDULES
M-601 85 10804/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
TEMPERATURE SENSOR
GREENHOUSE BAY
CONTROLLER INPUT/
OUTPUT SUMMARY
AN
AL
O G
IN
PU
T
AN
AL
O G
O U
TP
U
T
BI
N
AR
Y
IN
PU
T
BI
N
AR
Y
O U
TP
U
T
HUMIDITY SENSOR
FAN #1 START/STOP
FAN #2 START/STOP (LOW SPEED)
FAN #2 START/STOP (HIGH SPEED)
VENT WALL MOTOR (OPEN)
VENT WALL MOTOR (CLOSE)
EVAPORATING COOLING WALL START/STOP
UNIT HEATER
WALL VENT WALL OPEN LIMIT
WALL VENT CLOSE WALL LIMIT
X
X
X
X
X
X
X
X
X
X
X
VENT ROOF MOTOR (OPEN)
VENT ROOF MOTOR (CLOSE)
X
X
ROOF VENT WALL OPEN LIMIT
ROOF VENT CLOSE WALL LIMIT
X
X
NOTE: PROVIDE CONTROLLERS AS REQUIRED FOR THE
INPUT/OUTPUT/OUTPUT SUMMARY ABOVE. PROVIDE CENTRAL MONITORING
STATION IN THE GREENHOUSE MANAGERS OFFICE.
RAIN
WEATHER STATION
CONTROLLER INPUT/
OUTPUT SUMMARY
AN
AL
O G
IN
PU
T
AN
AL
O G
O U
TP
U
T
BI
N
AR
Y
IN
PU
T
BI
N
AR
Y
O U
TP
U
T
WIND DIRECTION
WIND SPEED
SOLAR K-LUX
OUTDOOR TEMPERATURE
X
X
X
X
X
NOTE: PROVIDE CONTROLLERS AS REQUIRED FOR THE INPUT/OUTPUT/OUTPUT
SUMMARY ABOVE. WEATHER STATION CONTROLLER TO BE BY SAME
MANUFACTURER TO GREENHOUSE BAY CONTROLLER.
OCCUPIED COOLING: STEPS TO MAINTAIN ADJUSTABLE SETPOINT AS
MEASURED BY TEMPERATURE SENSOR
STEP 1: OPEN SIDE VENTS. STEP 2:
COOLING 1 - ACTIVATE LOW SPEED OF TWO
SPEED FANS.
STEP 3: COOLING 2 - ACTIVATE HIGH SPEED OF TWO SPEED
FANS.
STEP 4: COOLING 3 - ACTIVATE EVAPORATIVE COOLING WALL
SYSTEM.
HEATING: STEPS TO MAINTAIN ADJUSTABLE SETPOINT
STEP 1: CLOSE ROOF AND SIDE VENTS.
STEP 2: HEATING 1 - MODULATE THE NEW ELECTRONIC VALVE
ACTUATOR TO MAINTAIN TEMPERATURE SETPOINT.
CONTROL SYSTEM SHALL MONITOR INDOOR AIR TEMPERATURE AND
HUMIDITY, OUTDOOR AIR TEMPERATURE, RAIN CONDITIONS, WIND DIRECTION
AND SPEED, AND SOLAR KLUX. CONTROL SYSTEM SHALL PROTECT
GREENHOUSE VENTILATION SYSTEMS FROM HIGH WINDS AND RAIN DAMAGE.
PROVIDE MANUAL OVERRIDE FOR ROOF VENTS. PROVIDE ALL WIRING AND
CONTROLS FOR A COMPLETE OPERATIONAL SYSTEM.
SEQUENCE OF OPERATION
ADD ALT #1 CIRC, FANS START/STOP X
EXTERIOR WALL
BACKDRAFT DAMPER
FAN SUPPORT AS PER
MANUFACTURER'S
RECOMMENDATIONS
WIND
DIRECTION
WIND SPEED
RAIN
NORTH
SOLAR K-LUX
OUTDOOR
TEMPERATURE
SECURELY MOUNT THE OUTDOOR
SENSOR AT THE HIGHEST UNOBSTRUCTED
POINT ON THE GREENHOUSE. OBSERVE
NORTH POSITIONING. INSTALL SENSOR
PER MANUFACTURER'S AND GREENHOUSE
MANUFACTURER'S RECOMMENDATIONS.
NEW EXHAUST
FAN
48"
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATE
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
J:\ gre en wo od \20
Jo bs \48
US
DA
To rna do
Da ma ge Re pa ir F
t. P ier ce
FL
\07 W ork ing
Fo lde r\M ec h\M -60
2.d wg
Ap r 2
7,
- 1
0:0 2a m c P.A.
FIRMTHE
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
MECHANICAL DETAILS
M-602 86 1084/27/26
BP
JH
JGM
SOUTHEAST AREA
STONEVILLE, MS
XXX
XXX
XXX
XXX
XXX
MIN
MIN
3.5"
2" MIN
6.5"
SCALE:
CONDENSATE DRAIN P-TRAP DETAIL
NOT TO SCALE
DRAIN PAN
DRAIN LINE SHALL BE AT LEAST THE
SAME SIZE AS THE NIPPLE ON THE
DRAIN PAN. SEE PLANS FOR SIZES.
UNION
PITCH DOWN TOWARD
FLOOR DRAIN. SPILL AT
FLOOR DRAIN.
UNION FOR DRAINING
CLEAN OUT
5/8" DIAMETER EXPANSION BOLTS
TYP. (6)
UNIT HEATER SHALL BE SECURED TO
WALL WITH A MINIMUM OF TWO BRACKETS
PER MANUFACTURER'S
RECOMMENDATIONS.
UNIT HEATER
TWO 5/8" DIAMETER BOLTS, EACH SIDE OF
FRAME WITH LOCK WASHERS.
AIR OUTLET
SCALE:
ELECTRIC UNIT HEATER DETAIL
NOT TO SCALE
NOTE:
INSULATE ALL CONDENSATE PIPING.
M602
M602
SCALE:
WEATHER STATION DETAIL
NOT TO SCALE
M602
SCALE:
WALL FAN MOUNTING DETAIL
NOT TO SCALE
M-602
STRAIGHT RACK
& PINION
INSECT SCREEN
RIDGE VENT MOTOR
ROOF VENT
SCALE:
ROOF VENT DETAIL
NOT TO SCALE
M602
SCALE:
EVAPORITIVE COOLING PAD & PUMP DETAIL
NOT TO SCALE
M602
HOSE BIBB
SUMP PUMP
FLOAT
SUMP TANK
FLOAT VALVE
1/2" MAKE-UP WATER
SHUT-OFF VALVE
120V POWER TO
STARTER
2-1/2" DRAIN
HOSE BIBB
PVC BALL VALVE
PVC UNION
MEDIA
PIPE SIZED PER
MANUFACTURER'S
RECOMMENDATIONS
FRAME SUPPORT
(TYP.)
HANG FROM ROOF STRUCTURE
PER GREENHOUSE MFG.
RECOMMENDATION
CHAIN (TYP. OF 4)
HORIZONTAL FLOW FAN
ADJUST HEIGHT FOR
OPTIMUM TEMPERATURE
DISTRIBUTION
SCALE:
HAF DETAIL
NOT TO SCALE
M602
HEATER
UNIT
SCALE:
GAS FIRED UNIT HEATER DETAIL
NOT TO SCALEM602
GAS CONTROL VALVE BALL VALVE
8" DIRT LEG W/CAP
UNION
TYPE B GAS VENT
SCALE:
PIPE HANGER DETAILS
N.T.S
M-602
12" MIN
12" MIN
U-CLAMP OR
CONDUIT CLAMP
GALVANIZED IRON
TRAPEZE OR
UNISTRUT
16 GAUGE GALVANIZED
SHEET SHIELD
WRAPPED FULLY
AROUND INSULATION
INSULATION
PIPE
PROVIDE A SECTION OF HIGH
COMPRESSION STRENGTH
INSULATION AT EACH HANGER
POINT. INSULATION SHALL BE HALF
ROUND AND EXTEND 2" BEYOND
GALVANIZED SHIELD EACH WAY.
16 GAUGE GALVANIZED
SHEET SHIELD
WRAPPED FULLY
AROUND INSULATION
INSULATION
PIPE
M
SPD
GFI
TC
PES
J
PNL
C
PB
T
1. DEVICES NOTED AS 'GFI' SHALL BE GROUND FAULT CIRCUIT INTERRUPTING DEVICES.
2. DEVICES NOTED AS 'WP' SHALL BE WEATHERPROOF WHILE-IN-USE.
3. PROVIDE UNSWITCHED POWER TO THE EMERGENCY BATTERY PACKS.
4. 'W/E' DENOTES PROVIDED WITH EQUIPMENT.
5. MINIMUM RACEWAY SIZE SHALL BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL RATIO TO LESS THAN 40% FULL.
6. THE ELECTRICAL CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH OTHER TRADES THROUGH THE GENERAL CONTRACTOR AND SHALL
BE RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT AND CORRECT ROUGH-IN LOCATIONS OF ELECTRICAL
CONNECTIONS.
7. VERIFY DOOR SWINGS WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN WALL SWITCHES. SWITCHES IN THE SAME LOCATION SHALL BE
GANGED TOGETHER IN ONE COMMON BACKBOX AND SHALL HAVE ONE COMMON FACE PLATE.
8. ALL FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN INSULATED GROUND CONDUCTOR, SIZED PER THE NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. MULTIPLE BRANCH CIRCUITS IN ONE RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR.
9. VERIFY LUMINAIRE, CEILING MOUNTED OCCUPANCY SENSOR LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS AND DIMENSIONS PRIOR TO INSTALLATION. VERIFY EXACT LOCATIONS OF MOTORS AND EQUIPMENT BEFORE ROUGHING-IN.
10. "PROVIDE" IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS ALL APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE DRAWINGS AND SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.
11. ALL CONDUCTORS SHALL BE COPPER
12. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE PROCUREMENT OF ANY MATERIALS AND
DEVELOPMENT OF ANY SHOP DRAWINGS OR SUBMITTALS.
13. PROVIDE LABELS ON ALL RECEPTACLES, WALL MOUNTED LIGHT SWITCHES/OCCUPANCY SENSORS AND JUNCTION BOXES INDICATING THE SOURCE
PANEL & CIRCUIT(S). TEXT SHALL BE BLACK, 1/4". LABELS ABOVE FINISHED CEILING CAN BE HANDWRITTEN WITH AN INDELIBLE MARKER.
14. CIRCUIT SIZES INDICATED ON THE DRAWINGS ARE MINIMUM REQUIREMENTS.
15. DO NOT CONNECT CONDUCTORS LARGER THAN #10 DIRECTLY TO A RECEPTACLE OR A SWITCH. PROVIDE A JUNCTION BOX TO DOWNSIZE THE
CONDUCTOR TO #12 AT THE DEVICE.
16. FOR INSTALLATION OF LIGHTING SWITCHES, MOUNT CENTERLINE OF BOX AT 46" A.F.F., UNLESS OTHERWISE INDICATED.
GENERAL NOTES:
1.
MASTER NOTES - ELECTRICAL:
THE CONTRACTOR MUST ABIDE BY ALL FEDERAL, STATE, AND/OR
LOCAL CODES. IF A DISCREPANCY BETWEEN CODES OCCURS, THE
MOST STRINGENT SHALL PREVAIL.
2. THE CONTRACTOR MUST FIELD VERIFY EXISTING CONDITIONS PRIOR TO
THE COMMENCEMENT OF ANY WORK. SHOULD DISCREPANCIES BE
DISCOVERED, THE CONTRACTOR MUST VERIFY INTENT WITH THE
ENGINEER/CONTRACTING OFFICER BEFORE PROCEEDING.
3. COORDINATE LOCATIONS OF ALL CEILING MOUNTED DEVICES WITH
OTHER TRADES PRIOR TO INSTALLATION.
4. COORDINATE ALL ROUGH-IN REQUIREMENTS FOR GOVERNMENT
FURNISHED EQUIPMENT WITH THE OWNER PRIOR TO BEGINNING
WORK. THESE DRAWINGS ARE BASED ON EXISTING BUILDING
CONSTRUCTION DRAWINGS, SITE SURVEYS, AND OWNER
FURNISHED EQUIPMENT SPECIFICATIONS.
5. RECEPTACLES MUST NOT BE CONNECTED IN A FEED-THRU
MANNER. WIRE CONNECTIONS IN
RECEPTACLE BOXES MUST BE MADE IN A PIGTAIL MANNER AS
SHOWN IN DETAIL 1/E-001.
SYMBOL / KEY DESCRIPTION
KEY NOTE DESIGNATION.
(NOT ALL SYMBOLS MAY APPLY, TYP.)
EP101
GENERAL SYMBOLS LEGEND
LA-1
LA-1
CONDUCTORS IN CONDUIT CONCEALED WITHIN WALL OR CEILING. TIC MARKS INDICATE NUMBER OF CONDUCTORS.
THE EQUIPMENT GROUNDING CONDUCTOR IS NOT SHOWN, BUT SHALL BE PROVIDED. SIZE THE EQUIPMENT GROUNDING CONDUCTOR AND THE CONDUIT PER THE NEC. THE ABSENCE OF TIC MARKS SIGNIFIES THAT TWO CONDUCTORS PLUS AN EQUIPMENT GROUNDING CONDUCTOR SHOULD BE PROVIDED. FOR EXAMPLE, THE MARKINGS TO THE LEFT SIGNIFY
THAT THREE CONDUCTORS PLUS AN EQUIPMENT GROUNDING CONDUCTOR SHOULD BE PROVIDED.
TOP DESIGNATION IS PLAN / ENLARGED PLAN / DETAIL NUMBER.
BOTTOM DESIGNATION IS SHEET LOCATION (STANDARD SYMBOL SCALED DOWN FOR LEGEND).
REVISION TAG DESIGNATION.
THE TEXT INSIDE THE ARC INDICATES THE AWG SIZE OF THE CONDUCTORS THAT SHALL BE RUN IN THE CONDUIT.
THE ABSENCE OF TEXT SIGNIFIES THAT THE CONDUCTORS SHOULD BE #12 AWG.
CIRCUITRY RUN IN STRAIGHT LINE SEGMENTS SIGNIFIES EXPOSED SURFACE-MOUNTED RACEWAY (SEE SPECIFICATIONS).
CONDUCTORS IN CONDUIT CONCEALED BELOW GRADE OR FLOOR. TIC MARKS INDICATE NUMBER OF CONFUCTORS.
THE EQUIPMENT GROUNDING CONDUCTOR IS NOT SHOWN, BUT SHALL BE PROVIDED. SIZE THE EQUIPMENT GROUNDING CONDUCTOR AND THE CONDUIT PER THE NEC. THE ABSENCE OF TIC MARKS SIGNIFIES THAT TWO CONDUCTORS PLUS AN EQUIPMENT GROUNDING CONDUCTOR SHOULD BE PROVIDED. THE MARKINGS TO THE LEFT SIGNIFY THAT THREE CONDUCTORS PLUS AN EQUIPMENT GROUNDING CONDUCTOR SHOULD BE PROVIDED.
HOMERUN TO PANELBOARD. ARC DENOTES CONCEALED CIRCUITRY. TEXT DENOTES PANELBOARD NAME WITH CIRCUIT NUMBER. DEVICES HAVING CIRCUIT NUMBERS LOCATED BESIDE THEM MAY NOT SHOW THE CIRCUIT
NUMBERS AT THE HOMERUN ARROWS.
PARTIAL HOMERUN TO PANELBOARD. COMBINE ALL PARTIAL HOMERUNS THAT ARE ON THE SAME CIRCUIT IN A
JUNCTION BOX PRIOR TO ENTERING THE PANELBOARD.
LOW VOLTAGE CONDUCTORS USED FOR MOTION DETECTOR CIRCUITRY. SEE MANUFACTURER'S
RECOMMENDATIONS FOR CONDUCTOR REQUIREMENTS.
PANELBOARD AND CIRCUIT DESIGNATIONLA1-13
S
ST
T
C
TELEPHONE MOUNTED IN BOX WITH HINGED DOOR
JUNCTION BOX FOR FUTURE TELEPHONE
CELLULAR AMPLIFIER ANTENNA
DUPLEX RECEPTACLE, NEMA 5-20R, MOUNTED 18" A.F.F. TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.
DUPLEX RECEPTACLE, NEMA 5-20R, MOUNTED WITH BOTTOM OF BOX 2" ABOVE COUNTER BACKSPLASH. WHERE THERE IS NO BACKSPLASH MOUNT 6" ABOVE COUNTER. WHERE RECEPTACLE IS SHOWN IN AN AREA WITH NO
COUNTER, MOUNT 45" A.F.F. TO CENTERLINE OF BOX.
SINGLE RECEPTACLE, NEMA 5-30R, MOUNTED 18" A.F.F. TO CENTERLINE OF BOX UNLESS NOTED OTHERWISE.
DUPLEX RECEPTACLE, NEMA 5-20R, SUSPENDED FROM CEILING. SEE DETAIL 3/E-002.
SYMBOL / KEY
POWER OUTLET AND COMMUNICATIONS LEGEND
J
J
CEILING MOUNTED JUNCTION BOX.
WALL MOUNTED JUNCTION BOX.
FLEX. CONNECTION TO EQUIPMENT.
F-?
NON-FUSED DISCONNECT SWITCH.
TEXT INDICATES AMPACITY/NUMBER
OF POLES/ENCLOSURE TYPE.
MAGNETIC MOTOR STARTER.
PANELBOARD.
VOLTAGE DROP CHART FOR 20A, 1Ø CIRCUITS
VOLTAGE CIRCUIT LENGTH CONDUCTOR SIZE (AWG)
120 >140'
>90'
>50'
<50' #12
#10
#8
#6
277 >330'
>200'
>130'
<130' #12
#10
#8
#6
VOLTAGE DROP CHART NOTES:
1) CIRCUIT SIZES INDICATED ON THE DRAWINGS ARE MINIMUM REQUIREMENTS.
REFER TO THIS CHART FOR UPSIZING CONDUCTORS AS NEEDED.
2) DO NOT CONNECT CONDUCTORS LARGER THAN #10 DIRECTLY TO A RECEPTACLE OR A SWITCH.
PROVIDE A JUNCTION BOX TO DOWNSIZE THE CONDUCTOR TO #12 AT THE DEVICE.
3) FOR CIRCUITS LONGER THAN THOSE LISTED ABOVE, CONSULT WITH THE ENGINEER FOR CONDUCTOR
SIZES.
DESCRIPTION
(42) ELECTRICAL OR COMMUNICATION DEVICE, MH = AT ELEVATION AFF INDICATED (42" AFF SHOWN)
TELEPHONE TERMINAL CABINET OR BACKBOARD
LIGHTING AND SWITCHING LEGEND
SYMBOL / KEY DESCRIPTION SYMBOL / KEY DESCRIPTION
SURFACE MOUNTED OR SUSPENDED FIXTURE.
SURFACE MOUNTED OR SUSPENDED
EMERGENCY FIXTURE.
MD
PASSIVE INFRARED AND ULTRASONIC DUAL
TECHNOLOGY OCCUPANCY SENSOR WITH A 26'
RADIAL COVERAGE. SURFACE MOUNTED TO CEILING.
POWER PACK SURFACE MOUNTED TO CEILING.
HORSEPOWER RATED SWITCH WITH THERMAL
OVERLOADS (MANUAL MOTOR STARTER).
SINGLE -POLE, SINGLE-THROW SWITCH.
S2
S3
S3P
DOUBLE POLE.
THREE WAY.
THREE POLE.
SYMBOL / KEY SYMBOL / KEYDESCRIPTION DESCRIPTION
ACP
ML
M
PX
PB
F
F
F PUSH TO EXIT BUTTON.
MAGNETIC LOCK.
POWER SUPPLY.PSACCESS CONTROL PANEL.
FIRE ALARM AND ACCESS LEGEND
MANUAL PULL STATION. MOUNT
48"A.F.F. TO CENTERLINE OF BOX.
STROBE. MOUNT 80" A.F.F. TO
BOTTOM OF BOX.
COMBINATION HORN & STROBE.
MOUNT 80"A.F.F. TO BOTTOM OF BOX.
MOTION DETECTOR TO
RELEASE MAGNETIC LOCK.
CR CARD READER.
PUSH BUTTON.
SYMBOL / KEY SYMBOL / KEYDESCRIPTION DESCRIPTION
ONE-LINE DIAGRAM, SCHEDULE, AND DISTRIBUTION LEGEND
FEEDER KEY
DISCONNECT SWITCH DIST
BOARD MTD.
CKT BREAK DIST BOARD MTD.
FUSE DIST BOARD MTD.
FUSED DISC SWITCH 600V & UNDER.
GROUND
XFMR
EQUIPMENT
GENERATOR
METER
SURGE PROTECTION DEVICE.
FUSED DISCONNECT SWITCH.
TEXT INDICATES AMPACITY/NUMBER
OF POLES/ENCLOSURE TYPE;
F-(RATING OF FUSES).
GROUND FAULT INTERRUPTER.
TIMECLOCK
PHOTOELECTRIC SWITCH
JUNCTION BOX
PULL BOX
TRANSFORMER
(PLAN VIEW)
CONTINUATION, UPSTREAM LABEL
LOCAL CONTACTOR
PANELBOARD
(ONE-LINE)
TRANSFER SWITCH
(ATS : AUTOMATIC)
(MTS: MANUAL)
MOTOR
AIR TERMINAL
GR
3/4" X 10' COPPER CLAD STEEL
GROUND ROD DRIVEN W/ TOP
ATLEAST 18" BELOW GRADE.
SA1 c cUPPERCASE INDICATES
TYPE OF FIXTURE
LOWERCASE INDICATES FIXTURES
TO BE CONTROLLED TOGETHER.
LOWERCASE INDICATES GROUP OF
FIXTURES TO BE CONTROLLED BY SWITCH.
PP
6. REFER TO ARCHITECTURAL DETAIL 1/G-103 FOR INFORMATION
REGARDING AREAS OF WORK FOR EACH BID OPTION AND PHASING.
1.
BID OPTION NOTES:
THE CONTRACTOR SHALL PROVIDE SEPARATE PRICING, INCLUDING
ALL DEMOLITION AND NEW WORK, BASED ON THE AREAS SHOWN
ON THE BID OPTION KEY PLAN. NO WORK SHALL BE EXCLUDED
BASED ON AREA BOUNDARIES; THE CONTRACTOR IS RESPONSIBLE
FOR COORDINATING ALL SCOPE NECESSARY TO DELIVER A
COMPLETE AND FUNCTIONAL RESULT FOR EACH BID OPTION.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
ELECTRICAL LEGEND
E-001 87 10804/27/2026
BP
EH
BTD
FT. PIERCE, FL
XXX
XXX
XXX
XXX
XXX
RECEPTACLE DETAIL NOTES:
A. THESE DRAWINGS ARE BASED ON THE BEST INFORMATION
AVAILABLE AT THE TIME OF DESIGN. COORDINATE WITH THE
MILLWORK CONTRACTOR TO DETERMINE THE EXACT LOCATION
OF OUTLETS BEING PLACED IN AND AROUND MILLWORK.
B. RECEPTACLES SHOWN AS GFI MAY BE NON GFI TYPE
RECEPTACLES IF FED FROM A 20/1 GFI BREAKER OR THE LOAD
SIDE OF A GFI RECEPTACLE IN THE SAME ROOM, ON THE SAME
CIRCUIT AND RATED 20 AMP FEED-THRU CAPACITY. COVER
PLATES SHALL BE CLEARLY MARKED GFI.
C. NON GFI RECEPTACLES SHALL NOT BE CONNECTED IN A
FEED-THRU MANNER. WIRE CONNECTIONS IN RECEPTACLE
BOXES SHALL BE MADE IN A PIGTAIL MANNER AS SHOWN IN
RECEPTACLE DETAIL.
BOND EQUIPMENT GROUND
TO METAL BOX.
SCALE:
RECEPTACLE DETAIL
NONE
E-001
BrandonBurton
4825 BD SEAL 260427
FINISH FLOOR
SUPPORT AND INSTALL ALL CONDUITS
PER THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE (NEC)
OUTLET BOXES SHALL BE RIGIDLY AND
SECURELY FASTENED IN PLACE TO
GREENHOUSE STRUCTURE OR BRACES.
SUPPORT GROUPS OF CONDUITS WITH ELECTRICAL STRUT SUPPORTED
BY THREADED RODS ANCHORED TO BUILDING STRUCTURE.
JUNCTION & PULL BOXES SHALL BE
RIGIDLY AND SECURELY FASTENED
IN PLACE TO GREENHOUSE
STRUCTURE OR BRACES.
NOTE: JUNCTION, PULL AND OUTLET BOXES
SHALL BE 4" x 4" x 2-1/8" OR LARGER.
SUPPORT WIRES MUST NOT BE USED FOR SUPPORT OF
CONDUITS. ROD & WIRE FASTENERS (BATWING CLIPS) SHALL
NOT BE USED FOR SUPPORT OF CONDUITS.
SUPPORT SINGLE CONDUITS WITH CONDUIT
HANGER STRAPS AND THREADED RODS
ANCHORED TO BUILDING STRUCTURE.
NOTE: ALL CONDUIT SHALL BE UV-RESISTANT
SCH. 80 PVC. ALL JUNCTION BOXES SHALL BE
WATERTIGHT POLYCARBONATE BOXES WITH
WEATHERPROOF GASKET AND FITTINGS.
CONDUIT INSTALLAITION SHALL COMPLY WITH
THE REQUIREMENTS LISTED IN ARTICLE 352 OF
THE NATIONAL ELECTRICAL CODE.
PLANT TABLE
12/3 UV-RESISTANT SOOW CORD
4" X 4" UV-RESISTANT POLYCARBONATE WATER-TIGHT JUNCTION BOX
STRAIN RELIEF CONNECTOR
JJ
APPROXIMATELY 48" ABOVE TABLE.
VERIFY MOUNTING HEIGHT WITH
OWNER.
RECEPTACLE DROP NOTES:
A. THE COMPLETE RECEPTACLE DROP INSTALLATION
SHALL BE COMPRISED OF COMPONENTS UL LISTED
FOR THE INTENDED PURPOSE.
NEMA L5-20R WATER-TIGHT LOCKABLE
RECEPTACLE
STRAIN RELIEF CONNECTOR
#10 HOMERUN
CONDUCTORS, 3/4"C.
6'-2"
6'-6" 5'-2"
4'
8'-2"
6'-6" 5'-2"
6'
4"x4" JUNCTION BOX ABOVE ACCESSIBLE
CEILING PROVIDED AND INSTALLED BY
CONTRACTOR.
TO ACCESS CONTROL PANEL
CR
NOTES:
COORDINATE ACCESS CONTROL REQUIREMENTS WITH
USDA MAINTENANCE PERSONNEL PRIOR TO INSTALLATION.
UTILIZE 20/1 CIRCUIT BREAKER LOCATED IN PANEL '1GE'.
THE CONTRACTOR SHALL REMOVE THE EXISTING ACCESS
CONTROL SYSTEM AT GREENHOUSE 101 AND 102 IN ITS
ENTIREETY AND PROVIDE A COMPLETE NEW ACCESS
CONTROL SYSTEM FOR GREENHOUSE 101 AND 102. THE
SYSTEM SHALL INCLUDE, BUT IS NOT LIMITED TO CARD
READERS, ELECTROMAGNETIC LOCKS, DOOR POSITION
SWITCHES, REQUEST-TO-EXIT DEVICES, POWER SUPPLIES,
CONTROL MODULES, ASSOCIATED WIRING, AND ALL
REQUIRED ACCESSORIES.
CEILING
3/4"C. WITH MULTI-CONDUCTOR ACCESS
CONTROL CABLE, PLENUM RATED TO ALL
DEVICES AT DOOR. ROUTE INDIVIDUAL
CABLES TO APPROPRIATE DEVICES.
CARD READER AS INDICATED ON FLOOR PLAN,
MOUNTED ON ENTRANCE SIDE OF DOOR AT 48"
A.F.F.
PX
M
PUSH-TO-EXIT PUSHBUTTON AS
INDICATED ON FLOOR PLAN,
MOUNTED ON EXIT SIDE OF DOOR
AT 48" A.F.F.
120V
TO FIRE ALARM CONTROL PANEL FOR
FIRE ALARM RELEASE
1"C. CONTAINING ACCESS CONTROL CABLING PER
MANUFACTURER'S INSTALLATION REQUIREMENTS.
3/4"C. CONTAINING CABLING PER MANUFACTURER'S
INSTALLATION REQUIREMENTS.
20A, SINGLE POLE TOGGLE SWITCH USED AS
A DISCONNECT FURNISHED AND INSTALLED
BY THE ELECTRICAL CONTRACTOR.
S
POWER SUPPLY/CONTROLLER MOUNTED ABOVE
ACCESSIBLE CEILING.
ML
PS
ML
SCALE:
GREENHOUSE CONTROLLER, ANNUNCIATOR, AND REMOTE VIEWING DETAIL
NONE
E-002
SCALE:
JUNCTION AND OUTLET BOX DETAIL
NONE
E-002
SCALE:
CEILING MOUNTED SUSPENDED RECEPTACLE DETAIL
NONE
E-002
SCALE:
DOUBLE GREENHOUSE PANEL DETAIL
NONE
E-002
MICROGROW CONTROLLER (ONE FOR EACH
GREENHOUSE). MECHANICAL EQUIPMENT
CONTACTORS/MOTOR STARTERS MOUNTED IN 12"x12"x8"D
GASKETED POLYCARBONATE BOX WITH HINGED COVER
BELOW. COORDINATE CONNECTION REQUIREMENTS WITH
THE MECHANICAL CONTRACTOR AND GREENHOUSE
CONTROLS CONTRACTOR PRIOR TO INSTALLATION. BRANCH CIRCUITS ROUTED ABOVE
ELECTRICAL GUTTER
SCALE:
SINGLE GREENHOUSE PANEL DETAIL
NONE
E-002
ELECTRICAL GUTTER
MICROGROW CONTROLLER. MECHANICAL EQUIPMENT
CONTACTORS/MOTOR STARTERS MOUNTED IN 12"x12"x8"D
GASKETED POLYCARBONATE BOX WITH HINGED COVER BELOW.
COORDINATE CONNECTION REQUIREMENTS WITH THE
MECHANICAL CONTRACTOR AND GREENHOUSE CONTROLS
CONTRACTOR PRIOR TO INSTALLATION. BRANCH CIRCUITS
ROUTED ABOVE
PANEL
1G*
PANEL
EXISTING FEEDER CONDUIT
EXISTING FEEDER CONDUIT
SCALE:
MAG-LOCK ACCESS CONTROL DETAIL
NONE
E-002
STRUCTURE ABOVE
22/2 TC CABLE, 3/4"C.PROCOM
CONTROLLER
GROWLINK
BOX
WEB-ALARM
BOX
NOTE: THE GREENHOUSE ENVIRONMENTAL CONTROL SYSTEM (MICROGROW OR
APPROVED EQUAL) FURNISHED BY THE MECHANICAL CONTRACTOR AND
INSTALLED BY THE ELECTRICAL CONTRACTOR SHALL BE PROGRAMMED AND
COMMISSIONED AS A COMPLETE AND FULLY OPERATIONAL SYSTEM. THE
CONTRACTOR SHALL COORDINATE DIRECTLY WITH THE GREENHOUSE CONTROL
SYSTEM MANUFACTURER AND/OR AUTHORIZED REPRESENTATIVE TO VERIFY ALL
EQUIPMENT REQUIREMENTS, WIRING METHODS, NETWORK ARCHITECTURE,
ANNUNCIATION, AND REMOTE MONITORING FEATURES.
120VAC
LOCATED IN
OFFICE. SEE
EP101 FOR
EXACT
LOCATION
LOCATED IN
OFFICE. SEE
EP101 FOR
EXACT
LOCATION
CAT6A CABLE, 1"C.
120VAC
NOTE: THE CONTRACTOR SHALL
UTILIZE INSULATED POLARIS
LUGS TO EXTEND EXISTING
FEEDER CIRCUITRY AS REQUIRED.
NOTE: THE CONTRACTOR SHALL
UTILIZE INSULATED POLARIS
LUGS TO EXTEND EXISTING
FEEDER CIRCUITRY AS REQUIRED.
NOTE: CONTROL CIRCUITS MAY BE COMBINED
INTO ONE CONDUIT. CONTROL CIRCUITRY
CONDUIT MUST HAVE LESS THAN 40% FILL
RATIO PER THE NATIONAL ELECTRICAL CODE.
TO GREENHOUSE ANNUNCIATOR PANEL. COORDINATE
EXACT REQUIREMENTS WITH GREENHOUSE
CONTROLS CONTRACTOR PRIOR TO INSTALLATION.
TO GREENHOUSE ANNUNCIATOR PANEL. COORDINATE
EXACT REQUIREMENTS WITH GREENHOUSE
CONTROLS CONTRACTOR PRIOR TO INSTALLATION.
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
ELECTRICAL DETAILS
E-002 88 10804/27/2026
BP
EH
BTD
FT. PIERCE, FL
XXX
XXX
XXX
XXX
XXX
1000/3
125/3 125/3
EXISTING PANEL 1VA, 1200A, 208Y/120V, 3Ø, 4W
125/3 125/3 60/3 60/3 125/3 125/3 60/3 90/3 60/3
TO XFMR T14
(300kVA, Z=5.87%)
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 109
AFC: 4,278A
VD(%): 0.53%
[ASSUMED 75']
PANEL '1GC'
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 101 & 102
AFC: 3,623A
VD(%): 1.35%
[ASSUMED 230']
PANEL '1GW'
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 119 & 120
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 113 & 114
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
PANEL '1GM'
[ASSUMED 160'] AFC: 4,684A
VD(%): 0.94%
GREENHOUSE 123 & 124
[ASSUMED 170'] AFC: 4,496A
VD(%): 1.00%
PANEL '1GH'
PANEL '1GK'
[ASSUMED 150'] AFC: 4,888A
VD(%): 0.88%
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 111 & 112
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 110
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 129
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 121
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 117 & 118
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 103
[ASSUMED 130'] AFC: 2,830A
VD(%): 0.93%
PANEL '1GA'
[ASSUMED 190'] AFC: 3,010A
VD(%): 1.28%
PANEL '1GS'
[ASSUMED 145'] AFC: 2,590A
VD(%): 1.03%
PANEL '1GL'
[ASSUMED 100'] AFC: 6,255A
VD(%): 0.59%
PANEL '1GD'
[ASSUMED 145'] AFC: 4,998A
VD(%): 0.85%
PANEL '1GB'
[ASSUMED 225'] AFC: 1,785A
VD(%): 1.60%
PANEL '1GX'
AFC: 14,186A
VD(%): 0.03%
60125 60 60 6090125 125 125 125 125
1000/3
125/3 125/3
EXISTING PANEL 1VB, 1200A, 208Y/120V, 3Ø, 4W
90/3 60/3 60/3 90/3 90/3 60/3 60/3 60/3 125/3
TO XFMR T15
(300kVA, Z=5.87%)
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 109
PANEL '1GG'
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 104
PANEL '1GU'
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 130
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 125 & 126
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
PANEL '1GF'
GREENHOUSE 107 & 108
PANEL '1GN'
PANEL '1GR'
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 128
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 105 & 106
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 122
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 127
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 115
SEE PANEL SCHEDULE
FOR EXACT INFORMATION
GREENHOUSE 131
PANEL '1GV'
PANEL '1GE'
PANEL '1GP'
PANEL '1GJ'
PANEL '1GQ'
PANEL '1GT'
AFC: 14,186A
VD(%): 0.03%
AFC: 2,020A
VD(%): 1.39%
[ASSUMED 195']
AFC: 2,065A
VD(%): 1.35%
[ASSUMED 190']
AFC: 2,727A
VD(%): 1.44%
[ASSUMED 215']
AFC: 4,161A
VD(%): 1.11%
[ASSUMED 190']
AFC: 3,941A
VD(%): 1.20%
[ASSUMED 205']
AFC: 4,240
VD(%): 1.08%
[ASSUMED 185']
AFC: 5,937A
VD(%): 0.32%
[ASSUMED 45']
AFC: 2,270A
VD(%): 1.21%
[ASSUMED 170']
AFC: 2,216A
VD(%): 1.25%
[ASSUMED 175']
AFC: 2,833A
VD(%): 1.38%
[ASSUMED 205']
AFC: 2,890A
VD(%): 1.34%
[ASSUMED 200']
1 1
6090125 60125 90 90 12560 60 60
PPM
REVISIONS
Agricultural
Service Research
DESCRIPTION
SHEET
DATEc P.A.
FIRM
U
NO.
DEPM
SAFETY & HEALTH
REAL PROPERTY
A
DATE
PROJECT NO.
SUSDA
BY
AGRICULTURAL RESEARCH SERVICE
OF
THE
DESIGNER
PROJECT MANAGER
JOB #
CHECKED BY
A-E FIRM
P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943
Johnson M Adams
ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT
USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
SINGLE LINE DIAGRAM
E-601 89 10804/27/2026
BP
EH
BTD
FT. PIERCE, FL
XXX
XXX
XXX
XXX
XXX
AFC: xxxxxA
EXISTING
NEW
X
1. EXISTING CONDUIT AND CIRCUITRY TO REMAIN
AND BE UTILIZED TO FEED NEW INSTALLATION.
2. EXTEND CIRCUITRY TO NEW PANEL AS
REQUIRED. UTILIZE INSULATED POLARIS LUGS
OR EQUAL (TYPICAL OF ALL PANELS). SPLICE
MUST OCCUR IN ACCESSIBLE LOCATION.
PROVIDE NEMA 4X BOX BELOW PANEL WHERE
SPLICE IS REQUIRED. SEE FEEDER SCHEDULE
FOR WIRE SIZE
CALCULATED AVAILABLE FAULT CURRENT
- (ALL SWITCHBOARDS, SWITCHGEAR, AND
PANELBOARDS SHALL HAVE THE AVAILABLE
FAULT CURRENT AND THE DATE THE
CALCULATION WAS PERFORMED FIELD
MARKED ON THE ENCLOSURE PER NEC
ARTICLES 408.6 AND 110.21(B)(3).) THE
CALCULATIONS SHALL BE UPDATED BY THE
ELECTRICAL ENGINEER ONCE ALL CIRCUITRY
IS INSTALLED AND CIRCUITRY LENGTHS
DOCUMENTED ON THE "AS-BUILT" DRAWINGS.
CALCULATIONS SHOWN ARE BASED ON THE
ASSUMPTIONS LISTED.
VOLTAGE DROP
- THE VOLTAGE DROP IS CALCULATED BASED
ON THE ASSUMPTIONS LISTED.
VD: X.XX%
SCALE:
SINGLE LINE DIAGRAM
NO SCALE
E601
EXISTING
NEW
FEEDER SCHEDULE
ID FEEDER AMPS FEEDER
60 60 4#4, #8(G)
90 90
125 125
4#2, #8(G)
4#1/0, #6(G)
U
D A
S USDA AGRICULTURAL RESEARCH SERVICE
US HORTICULTURAL RESEARCH LABORATORY
REPAIR TORNADO DAMAGE
FT. PIERCE, FL
ELECTRICAL PANEL SCHEDULES
E-701 90 10804/27/2026
BP
EH
BTD
FT. PIERCE, FL
XXX
XXX
XXX
XXX
XXX
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GA VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 110 EF-1 15 3 2
3 20 1 GREENHOUSE 110 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 110 RECS. 0.5 0.3 GREENHOUSE 110 EF-1 15 3 8
9 20 1 GREENHOUSE 110 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 110 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.5 0.3 GREENHOUSE 110 EF-1 15 3 14
15 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.5 0.3 - - - 16
17 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.5 0.3 - - - 18
19 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.5 0.2 GREENHOUSE 110 UH-1 20 1 20
21 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.4 0.2 GREENHOUSE 110 UH-1 20 1 22
23 20 1 GREENHOUSE 110 OVERHEAD RECS. 0.4 0.5 GREENHOUSE 110 HF 20 1 24
25 20 1 GREENHOUSE 110 ECP SUMP PUMP 0.5 0.5 GREENHOUSE 110 HF 20 1 26
27 20 1 GREENHOUSE 110 ROOF VENT 0.2 0.0 SPARE 30 1 28
29 20 1 GREENHOUSE 110 SIDE VENT 0.2 0.0 SPARE 20 1 30
31 20 1 SPARE 0.0 0.0 SPARE 20 1 32
33 20 1 SPARE 0.0 0.0 SPARE 20 1 34
35 20 1 SPARE 0.0 0.0 SPARE 20 1 36
37 20 1 SPARE 0.0 0.0 SPARE 20 1 38
39 20 1 SPARE 0.0 0.0 SPARE 20 1 40
41 20 1 SPARE 0.0 0.0 SPARE 20 1 42
TOTAL 4.0 3.2 3.7 * GFCI BREAKER
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GC VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 116 EF-1 15 3 2
3 20 1 GREENHOUSE 116 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 116 RECS. 0.5 0.3 GREENHOUSE 116 EF-1 15 3 8
9 20 1 GREENHOUSE 116 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 116 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.5 0.3 GREENHOUSE 116 EF-1 15 3 14
15 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.5 0.3 - - - 16
17 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.5 0.3 - - - 18
19 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.5 0.2 GREENHOUSE 116 UH-1 20 1 20
21 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.4 0.2 GREENHOUSE 116 UH-1 20 1 22
23 20 1 GREENHOUSE 116 OVERHEAD RECS. 0.4 0.5 GREENHOUSE 116 HF 20 1 24
25 20 1 GREENHOUSE 116 ECP SUMP PUMP 0.5 0.5 GREENHOUSE 116 HF 20 1 26
27 20 1 GREENHOUSE 116 ROOF VENT 0.2 0.0 SPARE 30 1 28
29 20 1 GREENHOUSE 116 SIDE VENT 0.2 0.0 SPARE 20 1 30
31 20 1 SPARE 0.0 0.0 SPARE 20 1 32
33 20 1 SPARE 0.0 0.0 SPARE 20 1 34
35 20 1 SPARE 0.0 0.0 SPARE 20 1 36
37 20 1 SPARE 0.0 0.0 SPARE 20 1 38
39 20 1 SPARE 0.0 0.0 SPARE 20 1 40
41 20 1 SPARE 0.0 0.0 SPARE 20 1 42
TOTAL 4.0 3.2 3.7 * GFCI BREAKER
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GE VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 122 EF-1 15 3 2
3 20 1 GREENHOUSE 122 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 122 RECS. 0.5 0.3 GREENHOUSE 122 EF-1 15 3 8
9 20 1 GREENHOUSE 122 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 122 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.5 0.3 GREENHOUSE 122 EF-1 15 3 14
15 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.5 0.3 - - - 16
17 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.5 0.3 - - - 18
19 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.5 0.2 GREENHOUSE 122 UH-1 20 1 20
21 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.4 0.2 GREENHOUSE 122 UH-1 20 1 22
23 20 1 GREENHOUSE 122 OVERHEAD RECS. 0.4 0.5 GREENHOUSE 122 HF 20 1 24
25 20 1 GREENHOUSE 122 ECP SUMP PUMP 0.5 0.5 GREENHOUSE 122 HF 20 1 26
27 20 1 GREENHOUSE 122 ROOF VENT 0.2 1.5 DAC-1 30 1 28
29 20 1 GREENHOUSE 122 SIDE VENT 0.2 0.2 FOYER ENTRANCE UH-1 20 1 30
31 20 1 SPARE 0.0 0.2 WALKWAY UH-1 20 1 32
33 20 1 SPARE 0.0 0.0 SPARE 20 1 34
35 20 1 SPARE 0.0 0.0 SPARE 20 1 36
37 20 1 SPARE 0.0 0.0 SPARE 20 1 38
39 20 1 SPARE 0.0 0.0 SPARE 20 1 40
41 20 1 HALLWAY LIGHTING 0.2 0.0 SPARE 20 1 42
TOTAL 4.1 4.7 4.1 * GFCI BREAKER
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GG VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 109 EF-1 15 3 2
3 20 1 GREENHOUSE 109 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 109 RECS. 0.5 0.3 GREENHOUSE 109 EF-1 15 3 8
9 20 1 GREENHOUSE 109 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 109 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.5 0.3 GREENHOUSE 109 EF-1 15 3 14
15 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.5 0.3 - - - 16
17 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.5 0.3 - - - 18
19 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.5 0.2 GREENHOUSE 109 UH-1 20 1 20
21 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.4 0.2 GREENHOUSE 109 UH-1 20 1 22
23 20 1 GREENHOUSE 109 OVERHEAD RECS. 0.4 0.5 GREENHOUSE 109 HF 20 1 24
25 20 1 GREENHOUSE 109 ECP SUMP PUMP 0.5 0.5 GREENHOUSE 109 HF 20 1 26
27 20 1 GREENHOUSE 109 ROOF VENT 0.2 0.0 SPARE 30 1 28
29 20 1 GREENHOUSE 109 SIDE VENT 0.2 0.0 SPARE 20 1 30
31 20 1 SPARE 0.0 0.0 SPARE 20 1 32
33 20 1 SPARE 0.0 0.0 SPARE 20 1 34
35 20 1 SPARE 0.0 0.0 SPARE 20 1 36
37 20 1 SPARE 0.0 0.0 SPARE 20 1 38
39 20 1 SPARE 0.0 0.0 SPARE 20 1 40
41 20 1 SPARE 0.0 0.0 SPARE 20 1 42
TOTAL 4.0 3.2 3.7 * GFCI BREAKER
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GJ VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 115 EF-1 15 3 2
3 20 1 GREENHOUSE 115 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 115 RECS. 0.5 0.3 GREENHOUSE 115 EF-1 15 3 8
9 20 1 GREENHOUSE 115 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 115 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.5 0.3 GREENHOUSE 115 EF-1 15 3 14
15 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.5 0.3 - - - 16
17 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.5 0.3 - - - 18
19 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.5 0.2 GREENHOUSE 115 UH-1 20 1 20
21 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.4 0.2 GREENHOUSE 115 UH-1 20 1 22
23 20 1 GREENHOUSE 115 OVERHEAD RECS. 0.4 0.5 GREENHOUSE 115 HF 20 1 24
25 20 1 GREENHOUSE 115 ECP SUMP PUMP 0.5 0.5 GREENHOUSE 115 HF 20 1 26
27 20 1 GREENHOUSE 115 ROOF VENT 0.2 0.0 SPARE 30 1 28
29 20 1 GREENHOUSE 115 SIDE VENT 0.2 0.0 SPARE 20 1 30
31 20 1 SPARE 0.0 0.0 SPARE 20 1 32
33 20 1 SPARE 0.0 0.0 SPARE 20 1 34
35 20 1 SPARE 0.0 0.0 SPARE 20 1 36
37 20 1 SPARE 0.0 0.0 SPARE 20 1 38
39 20 1 SPARE 0.0 0.0 SPARE 20 1 40
41 20 1 SPARE 0.0 0.0 SPARE 20 1 42
TOTAL 4.0 3.2 3.7 * GFCI BREAKER
PANEL LOCATION: GREENHOUSE CORRIDOR LUG LOCATION: BOTTOM FEED
1GL VOLT: 208Y/120V, 3Ø, 4W MAIN BUS: 60A MAIN BREAKER NEMA 3R ENCLOSURE
BUS: 100A MOUNTING: SURFACE PANELBOARD SCCR RATING (A): 10,000
CIRCUIT
NO.
BREAKER DESCRIPTION
PHASE LOAD (KVA)
DESCRIPTION BREAKER CIRCUIT
NO.AMPS POLES A B C AMPS POLES
1 20 1 LIGHTING 0.3 0.3 GREENHOUSE 121 EF-1 15 3 2
3 20 1 GREENHOUSE 121 CONTROL PANEL 0.5 0.3 - - - 4
5 20 1 SPARE 0.5 0.3 - - - 6
7 20 1 GREENHOUSE 121 RECS. 0.5 0.3 GREENHOUSE 121 EF-1 15 3 8
9 20 1 GREENHOUSE 121 RECS. 0.5 0.3 - - - 10
11 20 1 GREENHOUSE 121 RECS. 0.7 0.3 - - - 12
13 20 1 GREENHOUSE 121 OVERHEAD RECS.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .