This is a Hazardous Material Survey Report for the USDA Picos Research Farm located at 10001 Picos Road in Fort Pierce, Florida. The survey was conducted on February 18, 2026, by Terracon Consultants Inc. in preparation for planned demolition of six structures: the Lexian Greenhouse, Hoop Greenhouse, Laser Greenhouse, Well Filtration Structure, Filtration Structure, and Transfer Pump Structure.

The survey identified that asbestos was not detected in any of the 27 bulk samples collected from nine homogeneous areas across the structures. Lead-containing paint was detected in two of seven paint chip samples: red paint on a fiberglass tank at the Well Filter Structure (1,300 ppm) and grey paint on a metal motor at the Transfer Pump Structure (500 ppm). Polychlorinated biphenyls (PCBs) were not detected above method detection limits in five caulk samples collected, all below the regulatory threshold of 50 ppm. During the visual assessment, the survey identified various equipment requiring proper disposal or recycling considerations, including wall vent fans, space heaters, fertilizer solution pumps, electrical components, circuit breaker boxes, and motors. The report includes comprehensive regulatory overviews addressing NESHAP asbestos requirements, OSHA lead standards for construction, PCB regulations under TSCA, and universal and hazardous waste management requirements. Supporting documentation includes laboratory analytical reports from accredited laboratories, photographs of sampled areas and materials, professional licenses and certifications for the inspectors, and detailed sample location diagrams identifying all tested areas throughout the facility.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3347 NW 55th Street Fort Lauderdale, Florida 33319

P (954) 741-8282 Terracon.com

Facilities | Environmental | Geotechnical | Materials I

March 6, 2026

The Johnson McAdams Firm, P.A.

108 West Market Street Greenwood, MS 38930

Attn: Rebecca P. Palmer P: (662) 455-4945 E: becky.palmer@jmcfirm.com

Re: Hazardous Material Survey Report USDA Picos Research Farm 10001 Picos Road Fort Pierce, Florida 34945 Terracon Project No. 34267019

Dear Ms. Palmer:

The purpose of this report is to present the results of the hazardous material survey performed on February 18, 2026, on select structures at 10001 Picos Road in Fort Pierce, Florida. This survey was conducted in general accordance with Terracon proposal number P34267019, dated January 26, 2026.

We understand that these services were requested due to the planned demolition of the Lexian Greenhouse, Hoop Greenhouse, Laser Greenhouse, Well Filtration Structure, Filtration Structure and Transfer Pump Structure.

Asbestos was not detected in the samples collected from the structures onsite.

Lead-containing paint was detected in two of the seven paint chip samples collected from the structures. Please refer to the attached report for details.

Polychlorinated biphenyls (PCBs) were not detected above the method detection limit in the samples collected from the structures.

Items with proper disposal or recycling considerations, such as ballasts and fluorescent light tubes, were not observed.

Terracon appreciates the opportunity to provide these services to The Johnson McAdams Firm, P.A. If you have any questions regarding this report, please contact the undersigned at (954) 703-1865.

Sincerely, Terracon Consultants Inc.

Florida Asbestos Consulting Business License No. ZA337

Sergio A. Adasme

Project Industrial Hygienist

Michael W. Schrum, P.E.

Licensed Asbestos Consultant AX078

3347 NW 55th Street Fort Lauderdale, Florida 33319

P (954) 741-8282 Terracon.com

Facilities | Environmental | Geotechnical | Materials I

Hazardous Material Survey Report USDA Picos Road Farms

10001 Picos Road

Fort Pierce, Florida 34945

March 6, 2026 | Terracon Project No. 34267019

Hazardous Material Survey Report USDA Picos Road Farms | Fort Pierce, Florida 34945 March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials i

Table of Contents

Page No.

1.0 INTRODUCTION

1.1 Project Objective

1.2 General Conditions and Limitations

1.3 Reliance

2.0 BUILDING DESCRIPTION

3.0 FIELD ACTIVITIES

3.1 Asbestos

3.2 Lead Paint Sampling

3.3 Universal and Hazardous Waste

4.0 REGULATORY OVERVIEW

4.1 ASBESTOS

4.2 LEAD IN CONSTRUCTION

4.3 PCBS

4.4 UNIVERSAL AND HAZARDOUS WASTE

4.5 Hazardous Waste Disposal

5.0 FINDINGS AND RECOMMENDATIONS

5.1 ASBESTOS

5.2 LEAD PAINT

5.3 PCB EVALUATION

5.4 UNIVERSAL AND HAZARDOUS WASTE

6.0 GENERAL COMMENTS

Appendices Appendix A Asbestos Survey Sample Results Summary Appendix B Asbestos Laboratory Analytical Report Appendix C Lead Paint Laboratory Analytical Report Appendix D PCB Laboratory Analytical Report Appendix E Photographs Appendix F Licenses and Certifications Appendix G Sample Location Diagram

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 1

1.0 Introduction

Terracon Consultants, Inc. (Terracon) conducted a hazardous material survey of select structures at USDA Picos Road Farms addressed as 10001 Picos Rod in Fort Pierce, Florida 34945. The survey was conducted on February 18, 2026, by an AHERA-accredited Asbestos Building Inspector in general accordance with Terracon proposal number. P34267019, dated January 26, 2026.

Building components were visually assessed, and homogeneous areas of suspect asbestos-containing materials (ACM) were identified and documented. Paint chip samples were collected to determine the presence or absence of lead-containing paint. Caulk samples were collected and analyzed for the presence of Polychlorinated Biphenyls (PCBs) and the buildings were visually evaluated for the presence of potential universal and hazardous waste that would likely be disturbed or impacted during the planned demolition.

Asbestos sampling was performed in general accordance with EPA Asbestos Hazard Emergency Response Act (AHERA) sampling protocols, National Emission Standards for Hazardous Air Pollutants (NESHAP) regulations, and sampling methods outlined in the Occupational Safety and Health Administration (OSHA) standards 29 Code of Federal Regulations (CFR) 1910 and 29 CFR 1926. Suspect ACM samples were delivered to an accredited laboratory for analysis by Polarized Light Microscopy (PLM). Lead samples were analyzed by Flame Atomic Absorption Spectrophotometry Method SW846-3050B and PCBs were analyzed by EPA Method 3540C and 8082A.

1.1 Project Objective

Based on information provided by the client, we understand the purpose of this evaluation was to identify the presence and location of accessible friable and nonfriable ACM, lead-containing paints, PCBs in caulk, and potential universal or hazardous waste that would likely be disturbed/impacted during the planned upcoming demolition/renovation of the structures.

EPA regulation 40 CFR 61, Subpart M, National Emission Standards for Hazardous Air Pollutants (NESHAP), prohibits the release of asbestos fibers to the atmosphere during demolition activities. The asbestos NESHAP requires that potentially regulated asbestos-containing building materials be identified, classified, and quantified prior to planned disturbances or demolition activities.

The project objective also included a survey and testing of surface coatings for the presence of lead that may impact worker exposure to these materials (OSHA) as well as the potential for waste materials to become hazardous waste or regulated material with regulated disposal requirements. PCB and Universal Waste were also evaluated for proper disposal.

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 2

1.2 General Conditions and Limitations

The hazardous material survey encompassed the following areas:

Lexian Greenhouse

Hoop Greenhouse Laser Greenhouse Well Filter Structure (Water coming from reservoir) Filtration Structure (Water going to Irrigation System) Transfer Pump Structure

At the direction of The Johnson McAdams Firm, P.A. (Client), other areas of the facility and their associated materials were not included in the scope of this survey. The level of effort and associated tasks performed for this service was limited to the scope of services outlined in Terracon Proposal number. 34267019. Terracon did not attempt to identify every potential exposure or hazard present in the structures.

1.3 Reliance

This report is prepared for the exclusive use and reliance of the Client. Use or reliance by any other party is prohibited without the written authorization of the Client and Terracon.

Reliance on the report by the client and all authorized parties will be subject to the terms, conditions, and limitations stated in Terracon Proposal number P34267019, dated January 26, 2026.

2.0 Building Description

The facility was constructed between 1960 and 1970. The Lexian Greenhouse encompasses approximately 1,400 square feet and features a plexiglass-sheeted roof and exterior wall covering on metal frame, supported by interior and exterior concrete block walls on a concrete slab. The Hoop Greenhouse measures approximately 900 square feet and is constructed with a plexiglass-sheeted roof and exterior wall covering on a metal frame, on a limerock gravel floor. The Laser Greenhouse is approximately 1,600 square feet and at the time of the survey consisted of a remnant metal-frame without any walls or floors. The Well Filter Structure consisted of wooden poles supporting a sheet metal room on a concrete slab. The Filtration Structure consisted of fiberglass tanks and metal pipes mounted on a concrete slab without roof or walls. The Transfer Pump Structure measures approximately 500 square feet and is constructed of a steel frame with sheet metal roof and sides on a concrete slab.

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 3

3.0 Field Activities

The survey was conducted by Ryan Nanan and Jesse Beckles AHERA-accredited Asbestos Building Inspectors, Copies of the asbestos inspector’s certificates are attached in Appendix E. The survey was conducted in general accordance with the sample collection protocols established in EPA regulation 40 CFR 763 (AHERA). A summary of survey activities is provided below.

3.1 Asbestos

3.1.1 Visual Assessment

Our survey activities began with visual observation of the interior, exterior, and roof finishes of the structures likely to be impacted by planned demolition/renovation. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color, texture, and date of application. The assessment was conducted throughout visually accessible areas of the subject property. Building materials identified as glass, wood, or metal were not considered suspect ACM.

3.1.2 Physical Assessment

A physical assessment of each homogeneous area of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the EPA as a material, which can be crumbled, pulverized, or reduced to powder by hand pressure when dry. Friability was assessed by physically touching suspect materials.

3.1.3 Sample Collection

Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with AHERA sampling protocols. Random samples of suspect materials were collected in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.

Terracon collected 27 bulk samples from nine homogeneous areas of suspect ACM. A summary of suspect ACM samples collected during the survey is included as Appendix A.

3.1.4 Sample Analysis

Bulk samples were submitted under chain of custody to Eurofins Built Environment Testing East, LLC (Eurofins) in Fort Lauderdale, Florida for analysis by PLM with dispersion staining techniques per EPA methodology (EPA Method 600/R-93/116). The percentage of asbestos, where applicable, was determined by microscopic visual estimation. Eurofins is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP Accreditation No.

200738-0).

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 4

3.2 Lead Paint Sampling

The lead paint sampling was conducted by Mr. Ryan Nanan of Terracon. Paint chip samples were collected from homogenous painted surfaces identified to determine its lead content, measured by parts per million (ppm). Suspect lead paint samples were collected in general accordance with the EPA’s work practice standards for conducting lead paint activities (40 CFR 745.227). Currently, proposed renovation and demolition activities that could potentially disturb lead paint are subject to the OSHA regulations (29 CFR 1926.62 – Lead).

The lead paint sampling began with the Terracon representative walking the subject structures, to visually identify unique combinations of suspect lead paint. A unique combination of paint is based on paint color, building component, and substrate. A visual assessment of each unique combination of suspect lead paint was conducted to assess the condition of the paint. Based on the results of the visual observation, and after the sampling strategy was determined, Terracon collected seven paint chip samples from homogeneous surfaces.

Paint chip samples were submitted under a chain of custody to Eurofins of Tustin, California.

Paint chip samples were analyzed by Flame Atomic Absorption Spectrophotometry method SW846-3050B/7000B. Eurofins is an American Industrial Hygiene Association (AIHA) Environmental Lead Laboratory Accreditation (ELLAP) accredited laboratory (ELLAP Lab Code 100188). The lead paint laboratory analytical report is provided in Appendix C.

3.3 PCBs

In addition, Terracon collected five bulk caulk samples for laboratory analysis of PCBs by EPA Methods 3540C and 8082A. A summary of the PCB in caulk samples collected and the laboratory results are included in Appendix D.

3.4 Universal and Hazardous Waste

Terracon performed a visual assessment of miscellaneous or hazardous materials which may be impacted during the planned demolition/renovation to attempt to identify materials that may impact worker exposure to these materials (OSHA) as well as the potential for waste materials to become a hazardous waste or regulated material with regulated disposal requirements. Testing of the suspect hazardous materials identified was specifically excluded from this assessment. These miscellaneous hazardous or regulated materials may include batteries, mercury-containing equipment, such as thermostats and fluorescent light bulbs, ballasts, fire exit lighting, and smoke detectors.

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 5

4.0 Regulatory Overview

4.1 Asbestos

The following sections provide a general overview to the applicable asbestos regulations.

Please refer to the complete current regulation in order to verify compliance before any actions are initiated on an ACM.

4.1.1 NESHAP

The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to renovation or demolition activity.

Under NESHAP, asbestos-containing building materials are classified as:

1. Friable ACM,

2. Category I Non-Friable ACM, or

3. Category II Non-Friable ACM.

Friable materials are those that, when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. Category I Non-Friable ACM includes packings, gaskets, resilient floor coverings, and asphalt roofing products containing more than 1% asbestos. Category II Non-Friable ACM are any materials other than Category I Non-Friable ACM that contain more than 1% asbestos. Under NESHAP, Regulated Asbestos-Containing Materials (RACM) are classified as:

4. Friable ACM, or

5. Category I Non-Friable ACM that is in poor condition and/or has become friable, or

6. Category I Non-Friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or

7. Category II Non-Friable ACM that has a high probability of becoming or will become crumbled, pulverized, or reduced to powder by the forces expected to act upon the material in the course of renovation or demolition operations.

In the State of Florida, asbestos activities are regulated by the Florida Department of Environmental Protection (FDEP). Some counties have developed an enforcement division to carry out the responsibilities of the FDEP and have developed environmental and asbestos ordinances in which additional compliance is required. Since the facility is located in Palm Beach County, Florida, the NESHAP regulations are under the jurisdiction of the Palm Beach County Florida Department of Health (561-837-5900).

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 6

Per the NESHAP, RACM must be removed prior to renovation or demolition activities that will disturb the materials. Any removal of ACM or RACM must be conducted by a State of Florida-licensed asbestos abatement contractor, in compliance with Florida Statute (F.S) 469.001-014.

4.1.2 OSHA

OSHA’s general industry asbestos standard (29 CFR 1910.1001) requires employers to exercise due diligence in complying with the requirements to inform their employees and affected contractors working in the facility about the presence and location of both ACM and materials assumed to contain asbestos.

The OSHA Asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos during construction and maintenance activities. The standard classifies construction and maintenance activities which could disturb ACM, and specifies work practices and precautions which employers must follow when engaging in each class of regulated work. States which administer their own federally-approved state OSHA programs may require additional precautions.

A full copy of the OSHA asbestos standard for general and construction industry may be found at OSHA’s website (www.osha.gov) and should be referenced for specific information.

4.2 Lead in Construction

Lead is regulated by the EPA, U.S. Department of Housing and Urban Development (HUD), FDEP and OSHA. The EPA and FDEP regulate lead use, removal, and disposal, and OSHA regulates lead exposure to workers. The EPA and HUD, with their small child-safety focus, define Lead-Based Paint (LBP) as paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 mg/cm2, 5,000 ppm, or 0.5% by dry weight as determined by laboratory analysis.

However, for the purpose of the OSHA lead standard, with its focus on the safety/exposure of construction workers, lead-containing paint or LCP includes any detectable concentrations of metallic lead, all inorganic lead compounds, and organic lead soaps. A synopsis of the OSHA regulations (29 CFR 1926.62) and the applicability are as follows:

The OSHA Lead Standard for Construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending on the method of removal and other workplace conditions. The OSHA standard requires employee exposure to airborne lead to be maintained below the PEL of 50 micrograms per cubic meter of air (ug/m3) over an 8-hour TWA.

Under this standard, construction includes, but is not limited to, the following:

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 7

Demolition or salvage of structures where lead or materials containing lead are present

Removal or encapsulation of materials containing lead

New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead

Installation of products containing lead

Lead contamination/emergency clean-up

Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed

Maintenance operations associated with construction activities described above

4.3 PCBS

Total PCB concentrations in excess of 50 ppm in caulks and coatings, and adjacent building surfaces (such as masonry) may be considered PCB-contaminated and must be properly managed during renovation and demolition projects under the EPA 40 CFR 761, Polychlorinated Biphenyls (PCBs) Manufacturing, Processing, Distribution in Commerce, and Use Prohibitions regulations. However, applied dried paint and caulking are considered PCB bulk waste products, which may be disposed of in a facility permitted, licensed, or registered by the State as a municipal or non-municipal non-hazardous waste disposal site.

4.4 Universal and Hazardous Waste

Universal waste (UW) are specific hazardous waste streams (batteries, pesticides, mercury containing equipment and bulbs) that a generator can choose to manage in an alternative manner in place of the more complex hazardous waste requirements. These wastes are generated by numerous businesses, typically in small quantities. The Universal Waste Rules (UWR) are intended to promote recycling as well as proper disposal by easing certain regulatory requirements. The federal UWRs are located at 40 CFR 261. Waste must be a hazardous waste before it can be a universal waste. If a hazardous waste stream is not managed as a universal waste, then the waste must be managed as a hazardous waste under the applicable hazardous waste regulations.

It should be noted that any materials resulting from the release or clean-up of spills or breakage of any universal waste is not itself universal waste. It must be determined whether or not such materials are a hazardous waste as identified in 40 CFR 261, and the material must then be managed and disposed of in accordance with applicable hazardous or solid waste regulations.

The potential exists for PCB-containing ballasts that do not have a “No PCBs” label. If ballasts are not marked "No PCBs", they must be treated as containing PCBs. In 1978, EPA issued a ban on manufacturing equipment using PCBs, which most ballasts manufactured before 1978 contained, due to it being hazardous to both human health and the environment.

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 8

PCBs are regulated under the Toxic Substance Control Act (TSCA) through the EPA. The EPA regulates the specifics on proper management of PCBs. If the generator determines that the ballasts do not contain hazardous constituents and do not contain PCBs then they can be disposed of as solid waste; however, they must first be evaluated to determine if they are hazardous. If they are hazardous and will be disposed of, they must be managed as hazardous waste and cannot be disposed of in a solid waste dumpster or landfill. The EPA and state recommendations for management of non-leaking ballasts is recycling. Ballasts that are leaking and are determined, or assumed, to contain PCBs must be disposed properly at an EPA-approved facility.

The potential mercury-containing equipment category was added to the Federal Rule at 40 CFR 273 on August 5, 2005. It includes devices, items, or articles which contain elemental mercury that is integral to their functions, and which would otherwise be regulated as a hazardous waste when discarded by virtue of exhibiting the toxicity characteristic (TC) for mercury (hazardous waste code D009). Some examples of such items include mercury-containing thermostats (formerly a separate universal waste category in the original rule), thermometers, barometers, mercury switches, and certain types of meters, regulators, and gauges, in which elemental mercury is contained in ampules or otherwise enclosed and can be managed intact. This category does not include cathode ray tubes or other types of electronic equipment in which elemental mercury is not integral to function, nor does it include mercury waste that is generated as a by-product through the process of manufacturing or treatment.

4.5 Hazardous Waste Disposal

A waste material has the characteristic of “toxicity” if it can leach specific toxic substances into the soil or groundwater. A toxicity characteristic leachate procedure (TCLP) is used to determine the leachability of waste materials.

TCLP testing was not performed as part of our work scope; however, the results of paint testing can be used to determine whether TCLP testing may be needed or not. If analytical results from paint testing are equal to or more than 20 times the TCLP regulatory limit, the waste may be hazardous. Likewise, if the total concentration of a chemical is less than 20 times the TCLP regulatory limit, then the sample is not likely to leach a sufficient quantity of that constituent to exceed the TCLP limit.

5.0 Findings and Recommendations

5.1 Asbestos

Asbestos was not identified in the samples collected during the February 17, 2026, asbestos survey. A summary of the materials sampled is provided in Table 1 in Appendix A. The asbestos laboratory analytical report is included as Appendix B. If additional suspect materials are found during demolition activities, they should be assumed to contain asbestos until

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 9 laboratory analysis can confirm or deny their asbestos content. Photographs are provided in Appendix E.

5.2 Lead Paint

Lead was detected above the detection limit in the following two of the seven paint chip samples collected from representative painted building components:

Red Paint on Fiberglass Tank (Sample: L3) o Well Filter Structure

Grey Paint on Metal Motor (Sample L6) o Transfer Pump Structure

Contractors should be made aware of the presence of identified lead coatings, so that they may maintain compliance with worker protection regulations, employ lead-safe work practices, and/or conduct a negative exposure assessment per OSHA (29 CFR 1926.62 – Lead Exposure in Construction).

Please note that if any untested paints are encountered, they must be assumed to contain lead and addressed accordingly for OSHA compliance with the Lead in Construction Standard 29 CFR 1926.62 or otherwise sampled for laboratory analysis in an effort to refute the positive assumption.

The paint chip sample results are further summarized in Table 2, which is included in Appendix C. The laboratory analytical report and chain of custody are included in Appendix C.

5.3 PCB EVALUATION

Detectable PCB concentrations above the method detection limit were not identified in the 7 collected caulk samples. None of the caulk samples exceeded the regulatory threshold of 50 ppm. Applied dried paint and caulking are considered PCB bulk waste products, which may be disposed of in a facility permitted, licensed, or registered by the State as a municipal or non-municipal non-hazardous waste disposal site.

An analytical summary of the suspect caulk samples and Laboratory analytical reports of PCBs in paint and caulk are included in Appendix D. Representative photographs are included in Appendix E.

5.4 Universal and Hazardous Waste

Terracon observed two wall vent fans, two space heaters, two fertilizer solution pumps one each in the Lexian and Hoop Greenhouses. A circuit breaker box and electrical cut off switch were observed on the northwest exterior of the Lexian Greenhouse. An irrigation control box with a lithium Ion battery was observed on the east wall of the Lexian Greenhouse. Ceiling mounted electrical fans were observed on the ceilings of the Lexian Greenhouse. Three large

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials 10

Motors were observed onsite, one each in the Well Filter Structure (Water coming from reservoir), Filtration Structure (Water going to Irrigation System) and Transfer Pump Structure.

6.0 General Comments

The hazardous material survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions, and recommendations expressed in this report are based on conditions observed during our survey of the structures.

This report has been prepared on behalf of and exclusively for use by The Johnson McAdams Firm, P.A. for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information, which may have been used in the preparation of this report. No warranty, expressed or implied is made.

Pre-Demolition Hazardous Material Survey Report

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials

Appendix A

Asbestos Survey Sample Results Summary

HA

Sample Number

Description Sample Location Lab Results

1 1A Interior/Exterior Concrete Block and Mortar

Wall Lexian Greenhouse

Gray Concrete: None Detected Gray Mortar: None Detected

1 1B Interior/Exterior Concrete Block and Mortar

Wall Lexian Greenhouse

Gray Concrete: None Detected Gray Mortar: None Detected

1 1C Interior/Exterior Concrete Block and Mortar

Wall Lexian Greenhouse

Gray Concrete: None Detected Gray Mortar: None Detected

2 2A Interior/Exterior Concrete Slab Lexian Greenhouse Brown Paint: None Detected

Beige Texture: None Detected Gray Concrete: None Detected

2 2B Interior/Exterior Concrete Slab Lexian Greenhouse Brown Paint: None Detected

Beige Texture: None Detected Gray Concrete: None Detected

2 2C Interior/Exterior Concrete Slab Lexian Greenhouse Brown Paint: None Detected

Beige Texture: None Detected Gray Concrete: None Detected

3 3A Roof/Exterior Clear Caulking Lexian Greenhouse White Paint: None Detected

Transparent Caulk: None Detected

3 3B Roof/Exterior Clear Caulking Lexian Greenhouse White Paint: None Detected

Transparent Caulk: None Detected

3 3C Roof/Exterior Clear Caulking Lexian Greenhouse White Paint: None Detected

Transparent Caulk: None Detected

4 4A Interior White Door Frame Caulking Lexian Greenhouse White Paint: None Detected White Caulk: None Detected

4 4B Interior White Door Frame Caulking Lexian Greenhouse White Paint: None Detected White Caulk: None Detected

4 4C Interior White Door Frame Caulking Lexian Greenhouse White Paint: None Detected White Caulk: None Detected

5 5A Transparent Caulk Hoop Greenhouse Transparent Caulk: None Detected

5 5B Transparent Caulk Hoop Greenhouse Transparent Caulk: None Detected

5 5C Transparent Caulk Hoop Greenhouse Transparent Caulk: None Detected

6 6A Exterior Concrete Slab Hoop Greenhouse Gray Concrete: None Detected

6 6B Exterior Concrete Slab Hoop Greenhouse Gray Concrete: None Detected

6 6C Exterior Concrete Slab Hoop Greenhouse Gray Concrete: None Detected

7 7A Interior Concrete Slab Well Filter Structure Gray Concrete: None Detected

7 7B Interior Concrete Slab Well Filter Structure Gray Concrete: None Detected

7 7C Interior Concrete Slab Well Filter Structure Gray Stucco: None Detected

Gray Concrete: None Detected

Appendix A

Asbestos Survey Sample Results Summary USDA Picos Research Farm

10001 Picos Road

Terracon Project No. 34267019

A-1

HA

Sample Number

Description Sample Location Lab Results

Appendix A

Asbestos Survey Sample Results Summary USDA Picos Research Farm

10001 Picos Road

Terracon Project No. 34267019 Fort Pierce, Florida 34945

8 8A Interior Concrete Slab Filtartion Structure Gray Concrete: None Detected

8 8B Interior Concrete Slab Filtartion Structure Gray Concrete: None Detected

8 8C Interior Concrete Slab Filtartion Structure Gray Concrete: None Detected

9 9A Interior Concrete Slab Transfer Pump Structure Gray Concrete: None Detected

9 9B Interior Concrete Slab Transfer Pump Structure Gray Concrete: None Detected

9 9C Interior Concrete Slab Transfer Pump Structure Gray Concrete: None Detected

*Highlighted and bolded samples indicate materials with >1% asbestos.

*Bolded samples indicate materials with <1% asbestos.

A-2

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials

Appendix B

Asbestos Laboratory Analytical Report

Approved by:

Approved Signatory Orestes Mendez

Report for:

3347 NW 55th Street Fort Lauderdale, FL 33309

Regarding:

Eurofins Built Environment Testing East, LLC Project: Picos Farm; 10001 Picos Road Fort Pierce, FL

EML ID: 4420413

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Built Environment Testing East, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 02-20-2026 and 02-23-2026

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 200738-0

EMLab ID: 4420413, Page 1 of 8

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials

Appendix C

Lead Paint Laboratory Analytical Report

Sample ID Color Substrate Sample Location Paint Condition Test Result

(Lead in PPM)

L1 Blue Composite Plastic Pipe Well Filter Structure Good < 40

L2 Green Metal Pump Well Filter Structure Good < 39

L3 Red Fiberglass Water Filtration

Tank Well Filter Structure Good 1300

L4 Blue Composite Plastic Pipe Filtration Structure Good < 39

L5 Blue Metal Pipe Transfer Pump Structure Good < 39

L6 Grey Metal Motor Transfer Pump Structure Good 500

L7 Black Metal Pipe Transfer Pump Structure Good < 40

Terracon Project No. 34267019

< = Not detected above the analytical method’s reporting limit.

Bold: Analytical results indicate detectable lead concentrations above the analytical method’s reporting limit.

PPM = Parts Per Million

Appendix C Table 2

Lead Paint Chips Sample Results Summary USDA Picos Research Farm

10001 Picos Road

A-1

Approved by:

Approved Signatory Philip Newton

Report for:

3347 NW 55th Street Fort Lauderdale, FL 33309

Regarding:

Eurofins Built Environment Testing West, LLC Project: Picos Farm; 10001 Picos Road Fort Pierce, FL

EML ID: 4420413

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. Due to the nature of the analyses performed, field blank correction of results is not applied. The results relate only to the samples as received and tested. Sample size, as it relates to Wipe samples only, is supplied by the client.

Eurofins Built Environment Testing West, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results.

In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Lead - Flame AA: 02-23-2026

Service SOPs: Lead - Flame AA (EB-BC-S-8443) AIHA LAP, LLC accredited service, Lab ID #178697

Eurofins Built Environment Testing West, LLC's LabServe® reporting system includes automated fail-safes to ensure that all AIHA LAP, LLC quality requirements are met and notifications are added to reports when any quality steps remain pending.

EMLab ID: 4420413, Page 1 of 4

Horticultural Research Lab | Fort Pierce, Florida 34945 March 6, 2026 | Terracon Project No. 34267020

Facilities | Environmental | Geotechnical | Materials

Appendix D

PCB Laboratory Analytical Report

APPENDIX D

Table 3

PCBS IN CAULK SAMPLE SUMMARY TABLE

USDA PICOS ROAD FARMS

TERRACON PROJECT NO. 34267019

Sample

ID

Material Description Material Location PCB Content (mg/kg)

PCB1 Clear Caulking Lexian Greenhouse Exterior- Roof MDL

PCB2 Clear Caulking Lexian Greenhouse Exterior- Roof MDL

PCB3 Clear Caulking Lexian Greenhouse Exterior- Roof MDL

PCB4 Clear Caulking Hoop Greenhouse – Exterior Roof MDL

PCB5 Clear Caulking Hoop Greenhouse – Exterior Roof MDL

MDL – Method Detection Limit

Attn: Mr. Sergio Adasme Terracon Consulting Eng & Scientists

5371 NW 33 Avenue Suite 201

Fort Lauderdale, Florida 33309 Generated 2/25/2026 10:02:39 AM

Picos Farm

670-80986-1

See page two for job notes and contact information.

Altamonte Springs FL 32701

481 Newburyport Avenue

Eurofins Orlando

This report may not be reproduced except in full, and with written approval from the laboratory. The results relate only to the samples tested. For questions please contact the Project Manager at the e-mail address or telephone number listed on this page.

The test results in this report relate only to the samples as received by the laboratory and will meet all requirements of the methodology, with any exceptions noted. This report shall not be reproduced except in full, without the express written approval of the laboratory. All questions should be directed to the Eurofins Drinking Water and Wastewater Southeast, LLC Project Manager.

Generated

2/25/2026 10:02:39 AM

Authorized for release by Kaitlin Dylnicki, Project Manager kaitlin.dylnicki@et.eurofinsus.com (407)339-5984

Page 2 of 17 2/25/2026

Client: Terracon Consulting Eng & Scientists Project/Site: Picos Farm

Laboratory Job ID: 670-80986-1

Eurofins Orlando

2/25/2026

Cover Page

Table of Contents

Definitions/Glossary

Case Narrative

Detection Summary

Client Sample Results

Surrogate Summary

QC Sample Results

QC Association Summary

Lab Chronicle

Certification Summary

Method Summary

Sample Summary

Chain of Custody

Receipt Checklists

Page 4 of 17 2/25/2026

Client: Terracon Consulting Eng & Scientists Job ID: 670-80986-1 Project: Picos Farm

Eurofins Orlando

Page 5 of 17 2/25/2026

Page 6 of 17 2/25/2026

Page 7 of 17 2/25/2026

Page 8 of 17 2/25/2026

Page 9 of 17 2/25/2026

Page 10 of 17 2/25/2026

Page 11 of 17 2/25/2026

Page 12 of 17 2/25/2026

Page 13 of 17 2/25/2026

Page 14 of 17 2/25/2026

Page 15 of 17 2/25/2026

Page 16 of 17 2/25/2026

Page 17 of 17 2/25/2026

March 6, 2026 | Terracon Project No. 34267020

Facilities | Environmental | Geotechnical | Materials

Appendix E

Photographs

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials

Photo #1 HA-1 Interior/Exterior Concrete Block and Mortar Wall – Lexian Greenhouse

Photo #2 HA-2 Interior/Exterior Concrete Slab - Lexian Greenhouse

Photo #3 HA-3 Roof/Exterior Clear Caulking

- Lexian Greenhouse

Photo #4 HA-4 Interior White Door Frame Caulking

- Lexian Greenhouse

Photo #5 HA-5 Clear Roof Caulking – Clean Greenhouse – Hoop Greenhouse

Photo #6 HA-6 Exterior Concrete Slab – Hoop Greenhouse

March 6, 2026 | Terracon Project No. 34267019

Facilities | Environmental | Geotechnical | Materials

Photo #7 HA-7 Interior Concrete Slab – Well Filter Structure

Photo #8 Interior Concrete Slab Wall – Filtration Structure

Photo #9 HA-9 Interior Concrete Slab – Transfer Pump Structure

Photo #11 L6 Grey Paint on Metal Motor – Transfer Pump Structure

Photo #10 L3 Red Paint on Fiberglass Water Filtration Tank – Well Filtration Structure

March 6, 2026 | Terracon Project No. 34267020

Facilities | Environmental | Geotechnical | Materials

Appendix F

Licenses and Certifications certifies

Jesse Beckles 5504 NW 51st Avenue, Tamarac, FL, 33319

Having passed a 25-question exam with a score of 70% or higher has successfully met training requirements for

Asbestos Refresher: Inspector Online FDBPR Asbestos Licensing Unit: Provider #0000995; Course #FL49-0006389 (½ Day; 3.40 Contact Hours)

(Reaccreditation for Inspector under TSCA Title II/AHERA) Conducted

2/27/2026

Certificate #: 0091 - 004-45969 Exam Date: 2/27/2026 EPA accreditation expires: 2/27/2027 Principal Instructor: Brian Duchene, PE, LAC CEUs: 0.4 FBPR LAC: #0000995; Course ## 0006389 FBPE CEHs: #0004021; Course #0009083/Educational Institutions: 4 CEHs

March 6, 2026 | Terracon Project No. 34267020

Facilities | Environmental | Geotechnical | Materials

Appendix G

Sample Location Diagram

Sample Location Diagram USDA Picos Road Research Farm

Scale: Not to Scale 10001 Picos Road

Fort Pierce, FloridaProject Number: 34267019

1A

1B

1C 2A

2B

2C

3A

4B

5A

5B

4C

4A

3B 3C

5C

Lexian Greenhouse

6A 6B6C

Hoop Greenhouse

Laser Greenhouse

No Samples Taken

7C

7B

7A

Well Filter Structure

Filtration Structure

8A

8B

8C

Transfer Pump Structure

9C

9A

9B

L1L2

L3

L5

L4

L6

L7

Gravel Floor

Gravel Floor

PCB1

PCB2

PCB3

PCB5PCB4Asbestos Sample Locations

Lead Paint Sample Locations

PCB Sample Locations

File details come from the government source that posted it. Updated .