Attachment 3 - Site Maps.pdf

PDF 443 KB Posted

Attached to
Hurlburt Field - Dormitory Demolition Federal contract opportunity
Solicitation number
FA441720Q0018
Issued by
Department of the Air Force Special Operations Command

About this file

This document package includes site maps and utility diagrams for two dormitory buildings scheduled for demolition, along with details of the corresponding federal solicitation. The solicitation from the Department of the Air Force Special Operations Command seeks demolition services for two 3-story dormitory buildings located at Hurlburt Field in accordance with the attached Statement of Work. Site visit is scheduled for July 9, 2020 with questions and answers due by July 15th. The solicitation closing date is July 27, 2020. The site maps and diagrams provide location information and details of existing utilities at the buildings marked for demolition.

View the file

Other files for this federal contract opportunity

Show all 19

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

"M w

98:J

98:J

2" PVC

OVERFLOW

PVC

3-33

12"PVC

6" PVC

6" PVC

6" PVC

6" PVC

14" X 22"

6"

PVC

6"PVC

12" PEP

6" PVC12" PEP

6" D

IP

6" C

PVC

6" PVC

90339

90334

90333

90338

90331

90362

4-#500 MCM

4-#4/0 IN 2-1/2" COND

2-#8, 1-#8 GND IN 3/4" PVC COND

3-#10 IN 1" COND

3-#2

3-#2

3-#2 IN 4" CE DUCT

3-# 2 w

/CN IN 4"

CE DUCT

3-#250 MCM, 1/3 CN IN 5" HDPE COND

3-#23-#250 MCM, 1/3 CN IN 5" HDPE COND

4"

PV

C

6" PVC

4"PVC

4" VCP

4" PVC

4" PVC

4" PVC

6" VCP

8" PVC

8" VCP

1" PVC

6" PVC

6" PVC

6"

PVC

6" PVC

2"

4"

4" PVC

4"

4"

T553-1

T870-2

T431-1

T870-1

T870-3

LEGEND

STATE/FED WETLANDS

EM RESTORATION SITES

ESQD ARCS

FIRING RANGE SDZ AREAS

AIRSPACE IMAGINARY SURFACE LINE

ELECTRIC

PRIMARY UG IN CONDUIT/ENCASED

PRIMARY UG DIRECT BURIED

PRIMARY OH

SECONDARY UG IN CONDUIT

SECONDARY UG DIRECT BURIED

AIRFIELD LIGHTING UG

SECONDARY OH

! COUNTERPOISE SYSTEM

EMPTY/ABAND CONDUIT

!Õ REGULATOR

!* CAPACITOR

!Í MANHOLE

"e PRIMARY JUNCTION CABINET

"u HANDHOLE

"Ù PULL BOX

éÊ PNL/DISC/CNTRLR

÷ FUSED CUTOUT

³Ï SWITCH GEAR

%« VACUUM BREAKER

"U PRIMARY SWITCH

w

PAD-MTD TRANSFORMER

. POLE-MTD TRANSFORMER

!U ELECTRICAL GENERATOR

!R ELECTRICAL METER

" ELECTRICAL PEDESTAL

O EXTERIOR LIGHT

!< AIRFIELD LIGHT

!5 POLE

SUBSTATION

POL

SERVICE

MAIN

ABANDONED

!? VALVE

!Õ VALVE

# AIR ELIMINATOR

!â FILTER STRAINER

! FITTING

"̀ METER

"« PIG LAUNCH

"M PUMP

" PUMP STATION

TANK

COMMUNICATONS

LINE/DUCT

!( MANHOLE/VAULT/JUNCTION

# ANTENNA/POLE/RADAR/TOWER

") PEDESTAL

NATURAL GAS

MAIN

"̀ METER

"¹ REGULATOR

! FITTING

WATER

MAIN LINE

ABANDONED MAIN LINE

SERVICE LINE

ABANDONED SERVICE LINE

98:J FIRE DEPT CONNECTION

¬« FIRE HYDRANT

!. VALVE

PIV

"\ BACKFLOW PREVENTER

w FAUCET/HYDRANT/FOUNTAIN

! FITTING

"̀ METER

"M PUMP

" PUMP STATION

( DOMESTIC WATER WELL

DELUGE TANK

WATER TOWER

NON-POTABLE WATER

RE-USE MAIN LINE

RE-USE SERVICE LINE

RAW-WATER LINE

FIRE LINE

IRRIGATION LINE

!. VALVE

PIV

"\ BACKFLOW PREVENTER

w FAUCET/HYDRANT

# IRRIGATION SPRINKLER

! FITTING

"̀ METER

"M PUMP

"PUMP STATION

( IRRIGATION WELL

( EXTRACTION WELL

! TANK

WASTEWATER

GRAVITY MAIN

GRAVITY SERVICE

FORCE MAIN

!Z VALVE

! CLEANOUT

! FITTING

"i GREASE TRAP

"6 JUNCTION/DISTRIBUTION BOX

!j MANHOLE

"̀ METER

kF OIL-WATER SEPARATOR

" LIFT STATION

³q SEPTIC TANK

HOLDING TANKS

STORMWATER

MAIN LINE

SERVICE LINE

DRAIN FIELD LINE

ABANDONED

CULVERT

"B CATCH BASIN

" DROP INLET

"® CURB INLET

"Á JUNCTION BOX

!E MANHOLE

"M PUMP

#0 DISCHARGE POINT

! FITTING/CLEANOUT

TRENCH DRAIN

! DITCH/SWALE CENTERLINE

CONCRETE DITCH

FLUME/CUTOUT

RIP RAP

HEADWALL

WEIR

EROSION CONTROL MAT

POND/BASIN/SWALE

0 5025

Feet

Demolish Bldg 90334 Site Location and Utility Map w

3-13

27"

30"

CP

18" CP

6"

24"

RCP

6" D

IP (A

BAND)

6" C

PVC

6" DIP

Cody Aven ue 90361

90349

90326

90331

90329

90328

2-#6, 1-#8 GND IN 1" PVC COND

2-# 6, 1

-#8

GND IN

1"

PVC COND

3-#2 w/CN IN 4" CE DUCT

3-#

MCM, 1/

3 C

N IN

5"

HDPE C

OND

3-#2 w/CN IN 4" CE DUCT

3-#

MCM, 1/

3 CN IN 5"

HD

PE COND

3-#250 MCM, 1/3 CN IN 5" PVC COND

4"VCP

4"

6" VCP (ABAND)

6" V

CP

4" VCP

6" VCP (ABAND)

8"

VCP

8" VCP

LINED 8" VCP

LINED 8" VCP

LIN

ED 8"

VCP

6"

DIP

6" PVC

6"(ABAND)

4" (ABAND)

3/4" PVC

4"

4"

4"

4"

3/4"

T139-1

T444-1

T151-1

LEGEND

STATE/FED WETLANDS

EM RESTORATION SITES

ESQD ARCS

FIRING RANGE SDZ AREAS

AIRSPACE IMAGINARY SURFACE LINE

ELECTRIC

PRIMARY UG IN CONDUIT/ENCASED

PRIMARY UG DIRECT BURIED

PRIMARY OH

SECONDARY UG IN CONDUIT

SECONDARY UG DIRECT BURIED

AIRFIELD LIGHTING UG

SECONDARY OH

! COUNTERPOISE SYSTEM

EMPTY/ABAND CONDUIT

!Õ REGULATOR

!* CAPACITOR

!Í MANHOLE

"e PRIMARY JUNCTION CABINET

"u HANDHOLE

"Ù PULL BOX

éÊ PNL/DISC/CNTRLR

÷ FUSED CUTOUT

³Ï SWITCH GEAR

%« VACUUM BREAKER

"U PRIMARY SWITCH

w

PAD-MTD TRANSFORMER

. POLE-MTD TRANSFORMER

!U ELECTRICAL GENERATOR

!R ELECTRICAL METER

" ELECTRICAL PEDESTAL

O EXTERIOR LIGHT

!< AIRFIELD LIGHT

!5 POLE

SUBSTATION

POL

SERVICE

MAIN

ABANDONED

!? VALVE

!Õ VALVE

# AIR ELIMINATOR

!â FILTER STRAINER

! FITTING

"̀ METER

"« PIG LAUNCH

"M PUMP

" PUMP STATION

TANK

COMMUNICATONS

LINE/DUCT

!( MANHOLE/VAULT/JUNCTION

# ANTENNA/POLE/RADAR/TOWER

") PEDESTAL

NATURAL GAS

MAIN

"̀ METER

"¹ REGULATOR

! FITTING

WATER

MAIN LINE

ABANDONED MAIN LINE

SERVICE LINE

ABANDONED SERVICE LINE

98:J FIRE DEPT CONNECTION

¬« FIRE HYDRANT

!. VALVE

PIV

"\ BACKFLOW PREVENTER

w FAUCET/HYDRANT/FOUNTAIN

! FITTING

"̀ METER

"M PUMP

" PUMP STATION

( DOMESTIC WATER WELL

DELUGE TANK

WATER TOWER

NON-POTABLE WATER

RE-USE MAIN LINE

RE-USE SERVICE LINE

RAW-WATER LINE

FIRE LINE

IRRIGATION LINE

!. VALVE

PIV

"\ BACKFLOW PREVENTER

w FAUCET/HYDRANT

# IRRIGATION SPRINKLER

! FITTING

"̀ METER

"M PUMP

"PUMP STATION

( IRRIGATION WELL

( EXTRACTION WELL

! TANK

WASTEWATER

GRAVITY MAIN

GRAVITY SERVICE

FORCE MAIN

!Z VALVE

! CLEANOUT

! FITTING

"i GREASE TRAP

"6 JUNCTION/DISTRIBUTION BOX

!j MANHOLE

"̀ METER

kF OIL-WATER SEPARATOR

" LIFT STATION

³q SEPTIC TANK

HOLDING TANKS

STORMWATER

MAIN LINE

SERVICE LINE

DRAIN FIELD LINE

ABANDONED

CULVERT

"B CATCH BASIN

" DROP INLET

"® CURB INLET

"Á JUNCTION BOX

!E MANHOLE

"M PUMP

#0 DISCHARGE POINT

! FITTING/CLEANOUT

TRENCH DRAIN

! DITCH/SWALE CENTERLINE

CONCRETE DITCH

FLUME/CUTOUT

RIP RAP

HEADWALL

WEIR

EROSION CONTROL MAT

POND/BASIN/SWALE

0 5025

Feet

Demolish Bldg 90329 Site Location and Utility Map

Bldg 90334 Site Map
Bldg 90329 Site Map

File details come from the government source that posted it. Updated .