Attachment 3 - Site Maps.pdf
PDF 443 KB Posted
- Attached to
- Hurlburt Field - Dormitory Demolition Federal contract opportunity
- Solicitation number
- FA441720Q0018
About this file
This document package includes site maps and utility diagrams for two dormitory buildings scheduled for demolition, along with details of the corresponding federal solicitation. The solicitation from the Department of the Air Force Special Operations Command seeks demolition services for two 3-story dormitory buildings located at Hurlburt Field in accordance with the attached Statement of Work. Site visit is scheduled for July 9, 2020 with questions and answers due by July 15th. The solicitation closing date is July 27, 2020. The site maps and diagrams provide location information and details of existing utilities at the buildings marked for demolition.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bldg 90334 Toxic Substance Survey Report (Sep 2011).pdf | ||
| FA441720Q00180002 Updated 22 July.pdf | ||
| Attachment 1 - Statement of Work Updated 22 July.pdf | ||
| 90334 renovation demo drawings.pdf | ||
| Demolition Q and A.pdf | ||
| Solicitation Amendment FA441720Q00180002 SF 30.pdf | ||
| Solicitation Amendment - FA441720Q00180001.pdf | ||
| Attachment 6 - Instructions to Offerors (updated 21 July).pdf | ||
| Solicitation Amendment FA441720Q00180001 SF 30.pdf | ||
| Site Visit Sign-In Sheet.pdf | ||
| Surveys and Reports.pdf | ||
| FA441720Q0018.pdf | ||
| Attachment 7 - Evaluation of Offerors.pdf | ||
| Attachment 6 - Instructions to Offerors.pdf | ||
| Attachment 2 - Drawings.pdf | ||
| Attachment 5 - Wage Determination 2015-4531 (Rev 13).pdf | ||
| Attachment 8 - Past Performance Questionnaire.docx | DOCX document | |
| Attachment 4 - Pictures.pdf | ||
| Attachment 1 - Statement of Work.pdf |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
"M w
98:J
98:J
2" PVC
OVERFLOW
PVC
3-33
12"PVC
6" PVC
6" PVC
6" PVC
6" PVC
14" X 22"
6"
PVC
6"PVC
12" PEP
6" PVC12" PEP
6" D
IP
6" C
PVC
6" PVC
90339
90334
90333
90338
90331
90362
4-#500 MCM
4-#4/0 IN 2-1/2" COND
2-#8, 1-#8 GND IN 3/4" PVC COND
3-#10 IN 1" COND
3-#2
3-#2
3-#2 IN 4" CE DUCT
3-# 2 w
/CN IN 4"
CE DUCT
3-#250 MCM, 1/3 CN IN 5" HDPE COND
3-#23-#250 MCM, 1/3 CN IN 5" HDPE COND
4"
PV
C
6" PVC
4"PVC
4" VCP
4" PVC
4" PVC
4" PVC
6" VCP
8" PVC
8" VCP
1" PVC
6" PVC
6" PVC
6"
PVC
6" PVC
2"
4"
4" PVC
4"
4"
T553-1
T870-2
T431-1
T870-1
T870-3
LEGEND
STATE/FED WETLANDS
EM RESTORATION SITES
ESQD ARCS
FIRING RANGE SDZ AREAS
AIRSPACE IMAGINARY SURFACE LINE
ELECTRIC
PRIMARY UG IN CONDUIT/ENCASED
PRIMARY UG DIRECT BURIED
PRIMARY OH
SECONDARY UG IN CONDUIT
SECONDARY UG DIRECT BURIED
AIRFIELD LIGHTING UG
SECONDARY OH
! COUNTERPOISE SYSTEM
EMPTY/ABAND CONDUIT
!Õ REGULATOR
!* CAPACITOR
!Í MANHOLE
"e PRIMARY JUNCTION CABINET
"u HANDHOLE
"Ù PULL BOX
éÊ PNL/DISC/CNTRLR
÷ FUSED CUTOUT
³Ï SWITCH GEAR
%« VACUUM BREAKER
"U PRIMARY SWITCH
w
PAD-MTD TRANSFORMER
. POLE-MTD TRANSFORMER
!U ELECTRICAL GENERATOR
!R ELECTRICAL METER
" ELECTRICAL PEDESTAL
O EXTERIOR LIGHT
!< AIRFIELD LIGHT
!5 POLE
SUBSTATION
POL
SERVICE
MAIN
ABANDONED
!? VALVE
!Õ VALVE
# AIR ELIMINATOR
!â FILTER STRAINER
! FITTING
"̀ METER
"« PIG LAUNCH
"M PUMP
" PUMP STATION
TANK
COMMUNICATONS
LINE/DUCT
!( MANHOLE/VAULT/JUNCTION
# ANTENNA/POLE/RADAR/TOWER
") PEDESTAL
NATURAL GAS
MAIN
"̀ METER
"¹ REGULATOR
! FITTING
WATER
MAIN LINE
ABANDONED MAIN LINE
SERVICE LINE
ABANDONED SERVICE LINE
98:J FIRE DEPT CONNECTION
¬« FIRE HYDRANT
!. VALVE
PIV
"\ BACKFLOW PREVENTER
w FAUCET/HYDRANT/FOUNTAIN
! FITTING
"̀ METER
"M PUMP
" PUMP STATION
( DOMESTIC WATER WELL
DELUGE TANK
WATER TOWER
NON-POTABLE WATER
RE-USE MAIN LINE
RE-USE SERVICE LINE
RAW-WATER LINE
FIRE LINE
IRRIGATION LINE
!. VALVE
PIV
"\ BACKFLOW PREVENTER
w FAUCET/HYDRANT
# IRRIGATION SPRINKLER
! FITTING
"̀ METER
"M PUMP
"PUMP STATION
( IRRIGATION WELL
( EXTRACTION WELL
! TANK
WASTEWATER
GRAVITY MAIN
GRAVITY SERVICE
FORCE MAIN
!Z VALVE
! CLEANOUT
! FITTING
"i GREASE TRAP
"6 JUNCTION/DISTRIBUTION BOX
!j MANHOLE
"̀ METER
kF OIL-WATER SEPARATOR
" LIFT STATION
³q SEPTIC TANK
HOLDING TANKS
STORMWATER
MAIN LINE
SERVICE LINE
DRAIN FIELD LINE
ABANDONED
CULVERT
"B CATCH BASIN
" DROP INLET
"® CURB INLET
"Á JUNCTION BOX
!E MANHOLE
"M PUMP
#0 DISCHARGE POINT
! FITTING/CLEANOUT
TRENCH DRAIN
! DITCH/SWALE CENTERLINE
CONCRETE DITCH
FLUME/CUTOUT
RIP RAP
HEADWALL
WEIR
EROSION CONTROL MAT
POND/BASIN/SWALE
0 5025
Feet
Demolish Bldg 90334 Site Location and Utility Map w
3-13
27"
30"
CP
18" CP
6"
24"
RCP
6" D
IP (A
BAND)
6" C
PVC
6" DIP
Cody Aven ue 90361
90349
90326
90331
90329
90328
2-#6, 1-#8 GND IN 1" PVC COND
2-# 6, 1
-#8
GND IN
1"
PVC COND
3-#2 w/CN IN 4" CE DUCT
3-#
MCM, 1/
3 C
N IN
5"
HDPE C
OND
3-#2 w/CN IN 4" CE DUCT
3-#
MCM, 1/
3 CN IN 5"
HD
PE COND
3-#250 MCM, 1/3 CN IN 5" PVC COND
4"VCP
4"
6" VCP (ABAND)
6" V
CP
4" VCP
6" VCP (ABAND)
8"
VCP
8" VCP
LINED 8" VCP
LINED 8" VCP
LIN
ED 8"
VCP
6"
DIP
6" PVC
6"(ABAND)
4" (ABAND)
3/4" PVC
4"
4"
4"
4"
3/4"
T139-1
T444-1
T151-1
LEGEND
STATE/FED WETLANDS
EM RESTORATION SITES
ESQD ARCS
FIRING RANGE SDZ AREAS
AIRSPACE IMAGINARY SURFACE LINE
ELECTRIC
PRIMARY UG IN CONDUIT/ENCASED
PRIMARY UG DIRECT BURIED
PRIMARY OH
SECONDARY UG IN CONDUIT
SECONDARY UG DIRECT BURIED
AIRFIELD LIGHTING UG
SECONDARY OH
! COUNTERPOISE SYSTEM
EMPTY/ABAND CONDUIT
!Õ REGULATOR
!* CAPACITOR
!Í MANHOLE
"e PRIMARY JUNCTION CABINET
"u HANDHOLE
"Ù PULL BOX
éÊ PNL/DISC/CNTRLR
÷ FUSED CUTOUT
³Ï SWITCH GEAR
%« VACUUM BREAKER
"U PRIMARY SWITCH
w
PAD-MTD TRANSFORMER
. POLE-MTD TRANSFORMER
!U ELECTRICAL GENERATOR
!R ELECTRICAL METER
" ELECTRICAL PEDESTAL
O EXTERIOR LIGHT
!< AIRFIELD LIGHT
!5 POLE
SUBSTATION
POL
SERVICE
MAIN
ABANDONED
!? VALVE
!Õ VALVE
# AIR ELIMINATOR
!â FILTER STRAINER
! FITTING
"̀ METER
"« PIG LAUNCH
"M PUMP
" PUMP STATION
TANK
COMMUNICATONS
LINE/DUCT
!( MANHOLE/VAULT/JUNCTION
# ANTENNA/POLE/RADAR/TOWER
") PEDESTAL
NATURAL GAS
MAIN
"̀ METER
"¹ REGULATOR
! FITTING
WATER
MAIN LINE
ABANDONED MAIN LINE
SERVICE LINE
ABANDONED SERVICE LINE
98:J FIRE DEPT CONNECTION
¬« FIRE HYDRANT
!. VALVE
PIV
"\ BACKFLOW PREVENTER
w FAUCET/HYDRANT/FOUNTAIN
! FITTING
"̀ METER
"M PUMP
" PUMP STATION
( DOMESTIC WATER WELL
DELUGE TANK
WATER TOWER
NON-POTABLE WATER
RE-USE MAIN LINE
RE-USE SERVICE LINE
RAW-WATER LINE
FIRE LINE
IRRIGATION LINE
!. VALVE
PIV
"\ BACKFLOW PREVENTER
w FAUCET/HYDRANT
# IRRIGATION SPRINKLER
! FITTING
"̀ METER
"M PUMP
"PUMP STATION
( IRRIGATION WELL
( EXTRACTION WELL
! TANK
WASTEWATER
GRAVITY MAIN
GRAVITY SERVICE
FORCE MAIN
!Z VALVE
! CLEANOUT
! FITTING
"i GREASE TRAP
"6 JUNCTION/DISTRIBUTION BOX
!j MANHOLE
"̀ METER
kF OIL-WATER SEPARATOR
" LIFT STATION
³q SEPTIC TANK
HOLDING TANKS
STORMWATER
MAIN LINE
SERVICE LINE
DRAIN FIELD LINE
ABANDONED
CULVERT
"B CATCH BASIN
" DROP INLET
"® CURB INLET
"Á JUNCTION BOX
!E MANHOLE
"M PUMP
#0 DISCHARGE POINT
! FITTING/CLEANOUT
TRENCH DRAIN
! DITCH/SWALE CENTERLINE
CONCRETE DITCH
FLUME/CUTOUT
RIP RAP
HEADWALL
WEIR
EROSION CONTROL MAT
POND/BASIN/SWALE
0 5025
Feet
Demolish Bldg 90329 Site Location and Utility Map
| Bldg 90334 Site Map |
| Bldg 90329 Site Map |
File details come from the government source that posted it. Updated .