attachment_3_bid_3016_25.xlsx

XLSX spreadsheet 16 KB Posted

Attached to
CONTRACT: HIGH VOLTAGE ELECTRICAL SERVICES
Solicitation number
Bid 3016-25
Issued by
Rockingham County, New Hampshire

About this file

This spreadsheet details an electrical maintenance schedule for Pease Air National Guard Base (ANGB), outlining a comprehensive generator and electrical system maintenance plan spanning from 12 April to 21 April. The document provides a detailed breakdown of electrical system outages across multiple buildings and infrastructure components, including specific time slots for generator usage, partial and full generator operations, and maintenance windows for various facilities such as ramp lighting, fire pumps, offices, guard shacks, and critical infrastructure systems.

The maintenance schedule involves systematic electrical system interventions across different sections of the base, with outage durations typically ranging from 2-4 hours and specific time blocks allocated for each location. The plan appears to involve strategic electrical system maintenance, including work on switch gears, transformers, building generators, radio antenna systems, and various electrical panels with different voltage specifications (208V, 408V, 480V). The scheduling suggests a coordinated approach to minimizing operational disruptions while conducting necessary electrical maintenance and infrastructure upgrades at the Pease Air National Guard Base.

View the file

Other files

File Type Posted
attachment-1-bid-3016-25.docx DOCX document
attachment-2-bid-3016-25.pdf PDF
bid-3016-25-award.pdf PDF
attachment-3-bid-3016-25.xlsx XLSX spreadsheet
bid-3016-25.pdf PDF
attachment_2_bid_3016_25.pdf PDF
bid_3016_25.pdf PDF
attachment_1_bid_3016_25.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

Pease ANGB Electrical Maintenance Schedule
Switch GearTransformerBuildingGeneratorDurationOutage Schedule
2-1451491492-3 Hours13 April 0800-1600
152153,151151 Partial Generator2-4 Hours
157157, Radio Antennaantenna Generator2-4 Hours
145N145N, 157, Radio AntennaPartial Generator2-4 Hours
145S145Spartial Generator2-4 Hours
1-160165165, all of fuels area, MSA, Commercial Guard ShackFuels Generator2-4 Hours14 April 0800 - 1200
2-146Bldgs. 146 and 270?2-3 Hours14 April 1200 - 1400
146146
2-257257257Partial Generator2-4 Hours15 April 0800 - 1200
1561562-4 Hours15 April 0800 - 1400
TRNL (North Ramp Lights 270)TRNL (North Ramp Lights)2-4 Hours15 April 0800 - 1600
TEMP MPC (added to contract)TEMP MPC (added to contract)Full Generator15 April 0800 - 1000
3-2562562562-3 Hours14 April 1400 - 1600
264264partial Generator
3-254TAL (Tower 3-5 Apron Lights)TAL (Tower 3-5 Apron Lights)2-4 Hours19 April 0800 - 1200
254 Addition (408) Most of offices254 Addition (408) Most of officesMOCC generator2-4 Hours19 April 0800 - 1000
3-254 Fire Pump253 (480)253 (480)2-3 Hours19 April 1200 - 1400
254 Fire Pump254 Fire Pump2-4 Hours
Ramp LightingRamp Lighting
3-253253 (208)253 (208)being replaced at a later dateNONE
254 (408)254 (408)
254 (208)254 (208)
4-251251 (208)251 (208)being replaced at a later date12 April 0800 - 1600
251 (408)251 (408)
252 (208)252 (208)12 April 0800 - 1600
252 (408)252 (408)
4-2472472472-3 Hours12 April 0800 - 1600
243243Partial Generator12 April 0800 - 1600
4-245244 (208)244 (208)Partial Generator2-4 Hours12 April 0800 - 1600
244 (408) HVAC Ramp Lighting244 (408) HVAC Ramp LightingPartial Generator2-4 Hours
245245Partial Generator2-4 Hours
4-2492492492-4 Hours20 April 0800 - 1200
255255 & Main Guard ShackHas Cannon Plug2-4 Hours20 April 0800 - 1400
4-258262262Partial Generator2-3 Hours21 April 1200 - 1400
258258
1-1402-3 Hours20 April 1400 - 1600
Water TowerWater Tower2-4 Hours
B-100B-100
1-15T-259 reutilized for Bldg. 160 (BRDS)T-259 reutilized for Bldg. 160 (BRDS)Including Fire Alarm Contractor2-4 Hours21 April 0800 - 1200
SF 6 Switch Bldg. 100Need Help Checking
Main 13-254, 3-256, 3-253, 3-254 Fire Pump, 1-140, 1-15, 1-5, 1-160NONE
Main 22-146, 2-257, 2-145, 2-257, 2-245, 2-247, 4-251, 4-251, 4-258, 2-249,NONE

File details come from the government source that posted it. Updated .