Attachment_3-03_00_00_02_Dwgs-B-Rev5_ElephantButteReservoir_11x17_04-08-2024.pdf

PDF 47 MB Posted

Attached to
RG- EBHD UTILITY REHAB
Solicitation number
140R4024R0014
Issued by

About this file

This document appears to be Attachment 3-03_00_00_02_Dwgs-B-Rev5_ElephantButteReservoir_11x17_04-08-2024.pdf related to the federal contract opportunity RG- EBHD UTILITY REHAB, Solicitation Number 140R4024R0014 issued by the Department of the Interior Bureau of Reclamation.

The attachment likely contains drawings or technical specifications for the rehabilitation of utilities at the Elephant Butte Reservoir as part of the RG- EBHD UTILITY REHAB contract opportunity. The solicitation is seeking products and services to fulfill this requirement. Key details such as response due dates, award information, pricing terms, set-asides, or other salient information are not provided in this attachment alone. Additional documents related to the full solicitation would be needed to summarize those aspects.

View the file

Other files

File Type Posted
Sol_140R4024R0014_Amd_0004.pdf PDF
Attachment_2-00_00_50_-_Section_B_Rev_8-2-2024_0004.pdf PDF
Attachment_1-UPDATED_PRICE_SCHEDULE_Excel_8-2-2024-EBHD_Utility_Rehab_0004.xlsx XLSX spreadsheet
Attachment_5_Historical_Sewer_System_Drawings_0003.pdf PDF
Attachment_2-UPDATED_PRICE_SCHEDULE_Excel_7-30-2024-EBHD_Utility_Rehab_0003.xlsx XLSX spreadsheet
Attachment_3-00_00_50_-_Section_B_Rev_7-30-2024_0003.pdf PDF
Sol_140R4024R0014_Amd_0003.pdf PDF
Solicitation_Questions_Answers_as_of_7-30-2024_0003.docx DOCX document
Attachment_4_Historical_Drawings_-_24-508-10___52-59_0003.pdf PDF
Attachment_1_Site_Visit_Sign-In_Sheet_-_140R4024R0014_0003.pdf PDF
Solicitation_Questions_Answers_as_of_7-26-2024_0002.docx DOCX document
Sol_140R4024R0014_Amd_0002.pdf PDF
Sol_140R4024R0014_Amd_0001.pdf PDF
Attachment_1_EBHD_Lodging_Information_0001.docx DOCX document
Site_Visit_7-22-2024_Notes___Questions_Answers_0001.docx DOCX document
Attachment_2_Elephant_Butte__NM_Concrete_Tank_Insp_Rpt_0001.pdf PDF
Attachment_3_Elephant_Butte__NM_3_Steel_Tanks_Insp_Rpt_0001.pdf PDF
Attachment_7-SF25-16e_Performance_Bond_Form.pdf PDF
Attachment_8-DI-137_Release_of_Claims.pdf PDF
Attachment_5-PRICE_SCHEDULE_Excel_-_EBHD_Utility_Rehab.xlsx XLSX spreadsheet
Attachment_6-Notice_to_Contractors-CPARS_(December_2015).docx DOCX document
Attachment_2-00_00_01_Specifications_RevB6_060624_v4.pdf PDF
Attachment_1-Construction_Contract_Administration_Information.pdf PDF
Attachment_4-Davis-Bacon_Act_WD___NM20240012__3-22-2024.pdf PDF
Sol_140R4024R0014.pdf PDF
Attachment_7-SF25A-16e_Payment_Bond_Form.pdf PDF
Attachment_7-SF24-16e_Bid_Bond_Form.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

D

C

B

A

A

SA

FE

TY

AL

W

AY

S

TH

IN

K

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

AR

TM

EN

T O

F

TH

E

IN

TE

R

IO

R

DESIGNED

CHECKED

TECH. APPR.

APPROVED

R

IO

G R A N

D E

PR

O

JE

C

T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

Stephen Ogle

Stephen Ogle

DRAWN

Andrew Hadlan

Caitlin Kodweis, P.E.

Mike Kramer, P.E.

DENVER, CO 11/24/2023

DRAWING INDEX

24-D-60136

GENERAL

DRAWING NO. CONTENT DETAIL

24-D-60136 DRAWING INDEX SHEET 1

CIVIL

DRAWING NO. CONTENT DETAIL

24-D-60137 LOCATION AND KEY MAP GENERAL NOTES AND SYMBOLS

24-D-60139 SITE MAP

24-D-60140 SITE PLAN

24-D-60141 WASTEWATER PIPE PLANS

24-D-60142 WASTEWATER - PLAN AND PROFILE WELCOME CENTER AND CASITAS 1000+00 TO

1005+00

24-D-60143 WASTEWATER - PLAN AND PROFILE WELCOME CENTER AND CASITAS 1005+00 TO

1009+30

24-D-60144 WASTEWATER - PLAN AND PROFILE WELCOME CENTER AND CASITAS 1009+30 TO

END

24-D-60145 WASTEWATER - PLAN AND PROFILE RV PARK

24-D-60146 RV PARK UTILITY LOCATIONS

24-D-60147 WASTEWATER - PARTIAL SITE PLAN RV PARK

24-D-60148 WASTEWATER - PLAN HILLTOP HOUSING

24-D-60149 WASTEWATER - PLAN AND PROFILE HILLTOP HOUSING 3000+00 TO 3010+00

24-D-60150 WASTEWATER - PLAN AND PROFILE HILLTOP HOUSING 3010+00 TO END

24-D-60151 WASTEWATER - PLAN HOSPITAL CANYON

24-D-60152 WASTEWATER - PLAN AND PROFILE HOSPITAL CANYON

24-D-60153 WASTEWATER - PLAN FORCE MAIN

24-512-60154 WATER OVERALL PLAN

24-512-60155 WATER - PARTIAL PLAN HOSPITAL CANYON

24-512-60156 WATER - PLAN AND PROFILE HOSPITAL CANYON STA. 00+00 TO 5+05

24-512-60157 WATER - PLAN AND PROFILE HOSPITAL CANYON STA. 5+05 TO 10+39

24-512-60158 WATER - PLAN AND PROFILE HOSPITAL CANYON STA. 10+39 TO 15+33

24-512-60159 WATER - PLAN AND PROFILE HOSPITAL CANYON LOOP STA. 16+00 TO

21+27

24-512-60160 WATER - PLAN AND PROFILE HOSPITAL CANYON LOOP STA. 21+27 TO

26+43

24-512-60161 WATER - PLAN AND PROFILE HOSPITAL CANYON LOOP STA. 26+43 TO

31+77

24-512-60162 WATER - PARTIAL PLAN WELCOME CENTER, CASITAS, AND RV PARK

24-512-60163 WATER - PLAN AND PROFILE WELCOME CENTER STA. 32+00 TO 37+32

24-512-60164 WATER - PLAN AND PROFILE WELCOME CENTER STA. 37+32 TO 43+11

24-512-60165 WATER - PLAN AND PROFILE WELCOME CENTER STA. 43+11 TO 48+61

24-512-60166 WATER - PLAN AND PROFILE CASITAS STA. 49+00 TO 53+76

24-512-60167 WATER - PLAN AND PROFILE CASITAS STA. 53+76 TO 57+65

24-512-60168 WATER - PLAN AND PROFILE RV PARK STA. 58+00 TO 62+48

24-512-60169 WATER - PLAN AND PROFILE RV PARK STA. 62+48 TO 66+05

24-512-60170 WATER - PLAN AND PROFILE HILLTOP HOUSING

24-512-60171 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 70+00 TO 74+07

24-512-60172 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 74+07 TO 78+35

24-512-60173 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 78+35 TO 83+03

24-512-60174 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 83+03 TO 87+34

24-512-60175 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 87+34 TO 92+70

24-512-60176 WATER - PLAN AND PROFILE HILLTOP HOUSING STA. 92+70 TO 98+02

24-512-60177 WATER - PLAN AND PROFILE HILLTOP HOUSING LOOP STA. 99+00 TO

104+03

24-512-60178 WATER PUMPHOUSE

24-512-60179 WATER MAIN LINE CONNECTION AND FIRE HYDRANT

24-512-60180 WATER THRUST CONTROL BLOCKS

24-512-60181 WATER VALVE AND METER BOX

24-512-60182 WATER JOINT RESTRAINT

24-D-60183 TYPICAL SANITARY MANHOLE AND

CONNECTIONS

24-D-60184 UTILITY TRENCH

24-D-60185 RV CONNECTION ELECTRIC, SEWER, & WATER

24-512-60186 ADA RV CONNECTION ELECTRICAL AND WATER

STRUCTURAL

DRAWING NO. CONTENT DETAIL

24-D-60188 ELECTRICAL EQUIPMENT FOUNDATIONS PLANS AND SECTIONS - CONCRETE OUTLINE

AND REINFORCEMENT DESIGN

ELECTRICAL

DRAWING NO. CONTENT DETAIL

104-D-1150 DESIGNATIONS AND SYMBOLS SINGLE-LINE AND SCHEMATIC DIAGRAMS

24-D-60191 ELECTRICAL SITE DEMOLITION

24-D-60192 ELECTRICAL SITE PLAN

24-D-60193 CASITAS SINGLE-LINE DIAGRAM

24-D-60194 RV PARK SINGLE-LINE DIAGRAM

24-D-60195 CHARGING STATIONS SINGLE-LINE DIAGRAM

24-D-60196 CASITAS PANEL SCHEDULES

24-D-60197 CASITAS AND RV PARK PANEL SCHEDULES

24-D-60198 CHARGING STATIONS PANEL SCHEDULES

24-D-60199 CASITAS CABLE AND CONDUIT SCHEDULE

24-D-60200 RV PARK AND CHARGING STATIONS CABLE AND CONDUIT SCHEDULE

24-D-60201 SITE LIGHTING PLAN

24-D-60202 RESTAURANT PARKING LOT LIGHTING PLAN

24-D-60203 BOAT RAMP AND RV PARK LIGHTING PLAN

COMMUNICATIONS

DRAWING NO. CONTENT DETAIL

24-D-60205 FIBER - PLAN OVERALL

24-D-60206 NETWORK STANDARD CONTROL ENCLOSURE LAYOUT

STANDARD

DRAWING NO. CONTENT DETAIL

40-D-4334 ELECTRICAL INSTALLATION TYPICAL GROUNDING DETAILS

40-D-4335 ELECTRICAL INSTALLATION TYPICAL GROUNDING DETAILS

40-D-6234 STANDARD DESIGNS STANDARD NAMEPLATES

40-D-6551 PRESSURE PIPE TRENCH INSTALLATION SELECT MATERIAL

40-D-6552 PRESSURE PIPE TRENCH INSTALLATION SOIL CEMENT SLURRY

40-D-6576 SWITCHYARDS AND SUBSTATIONS BURIED CONDUIT FOR LOW VOLTAGE

CABLES

40-D-7094 ELECTRICAL INSTALLATION CONDUIT CLAMP AND CONDUIT SUPPORTS

TYPICAL DETAILS

40-D-60001 ELECTRICAL EQUIPMENT SUPPORT SECTIONS AND DETAILS

40-D-60002 TYPICAL GUARD POSTS NON-SECURITY APPLICATION

40-D-60003 GENERAL NOTES FOR CONCRETE OUTLINE

AND REINFORCEMENT

40-D-60004 MINIMUM REQUIREMENTS FOR DETAILING

REINFORCEMENT

INFORMATION/REFERENCE DRAWINGS

DRAWING NO. CONTENT DETAIL

CO DEPT OF TRANSPORTATION MANHOLE (TRAFFIC MANAGEMENT SYSTEM) INTERIOR DETAIL (SIDE VIEW)

TANK REPLACEMENT - PRICE SCHEDULE B

DRAWING NO. CONTENT CONTENT

24-512-60222 WATER TANKS ELEVATION, SECTION, PLAN, AND DETAIL

24-512-60223 WATER TANKS ELEVATION, SECTION, PLAN, AND DETAIL

Digitally signed by MICHAEL KRAMER Date: 2023.11.27 13:29:15 -07'00'

New Mexico

W

S

Overhead power line

Buried electric

Sewer

Water

Fiber optic

Centerline

Force Main

Chain link fence

Cleanout

Manhole

LEGEND

F

E

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

LOCATION AND KEY MAP

GENERAL NOTES AND

SYMBOLS

DENVER, CO

24-D-60137

Sierra County

Project site

GENERAL NOTES

1. General Notes, Legend, and Abbreviations apply to all drawings.

2. Unknown elevations and diameters of existing utilities shall be determined by the Contractor and reported to the COR in accordance with Specifications.

3. Not all utilities shown, Contractor to locate and protect per Specifications.

4. Contractor shall shore or slope all excavations as needed for safety.

5. For utility trenching details, see (60184).

ABBREVIATIONS

Cl - Centerline CMP - Corrugated metal pipe Cont. - Continued E - Electrical F - Fiber Optic FM - Force main INV - Invert MH - Manhole NGS - National Geodetic Survey OHE - Overhead electric RCP - Reinforced concrete pipe Rd - Road S - Sewer SCP - Survey control point UGE - Underground electric W - Water WW - Wastewater WWTP - Wastewater treatment plant WC - Welcome Center

PROJECT DATUMS

Horizontal: New Mexico State Plane - West Zone, U.S. Survey ft based on the NAD83 datum Grid to Ground correction factor: 1.00025130

Vertical: NAVD88, U.S. Survey ft Geoid 18

KEY MAP

Not to Scale

LOCATION MAP

Not to Scale

Approximately 5 miles to Truth or Consequences

NGS BENCHMARKS

Name PID

U 86 DS0847

R 232 DS0848

Elephant Butte Reservoir

Project site SURVEY CONTROL POINTS Point Northing Easting Elevation

Base/Opus point 781811.26 2922022.51 4532.87

SCP1 780775.24 2922197.75 4458.62

SCP2 781536.74 2922637.29 4431.59

SCP3 782307.22 2922016.87 4404.94

SCP4 781795.34 2921372.51 4475.31

SCP5 781021.14 2920076.90 4581.52

SCP6 781752.99 2920761.99 4625.38

SCP7 782575.50 2920457.53 4462.17

SCP8 783342.50 2919999.11 4579.14

EL

EV

A

TI

O N

STATION

1000+00 1001+00 1002+00 1003+00 1004+00 1005+00

El. 4446.46

S=-0.00380

S=-0.00390

S=-0.00380

S=-0.00390

B eg in W

W W

C t o lif t st at io n M

H -1

.9

A s-bu ilt

M H

-1 no t vi si bl e

Fi el d ve ri fy

El. 4448.38

El. 4447.26El. 4447.49

S=-0.00380

.8

C en te r of

0" C

M P

C ro ss in g

WW WC to lift station Inv.

F

F

F

F

F

F

F

F

F

F F

F

F

F

F

F

F

F

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

E

E E

E

E

E

E

E

E

E

E

W

W

W

Edge of asphalt, typ.

Retaining wall

1002+95.97 As-built MH 16 MH not visible N=782242.24 E=2921882.48

1000+00 Begin WW WC to lift station As-built MH-15 N=782310.42 E=2921594.41

MH not on as-built, visible in field N=782117.20 E=2922020.35

1002+33.89 Center of 30" CMP crossing N=782255.90 E=2921821.83

Welcome Center

Existing cleanout, see General Notes-

Wastewater (60141)

Fiber optic line, see Note 3

See Note 1

Water line, see Note 5

Existing buried electrical line, see Specifications regarding preservation

Buried parallel electrical & fiber optic lines, see Notes 3 & 4

Existing overhead electrical line to be removed, see Note 2

Inv. El.=4448.02

Inv. El.=4445.67

WW WC to Lift Station, replace existing WW in-kind

Existing buried electric line, see Specifications regarding preservation

Existing buried electric line, see Specifications regarding preservation

Existing overhead electrical pole

E

E

WW WC TO LIFT STATION ALIGNMENT

See General Civil Note (60139) casitas, typ.

M

AT

CH

L

IN

E

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

WELCOME CENTER AND

CASITAS 1000+00 TO

1005+00

DENVER, CO

24-D-60142

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

Existing ground

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

8DR25

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber optic

4. See (60192) for Electrical

5. See (60154) for Water

A

TI

O N

STATION

1005+00 1006+00 1007+00 1008+00 1009+00 1009+30

El. 4444.59

El. 4446.46 S=-0.00451

.8

A s-bu ilt

M H

-1 no t vi si bl e fie ld v er ify

.5

A s-bu ilt

M H

-1

S=-0.00451

El. 4444.60

El. 4446.00

S=-0.00390 WW WC Inv.

S

S

S

S

S

S S

S S

S S

S S S S

S

W

W

W

W W

W W

W W

W W

W W

W

W

E

E

E

E

E

E E

E E

E E

E E

E

E

F

F

F

F

F F

F F

F F

F F F

Existing cleanout, see General Notes- Wastewater (60141)

Water line, see Note 5

See Note 1

Parallel electrical & fiber optic lines, see Notes 3 & 4

Existing overhead electrical line to be removed, see Note 2

WW WC to Lift Station, replace existing WW in-kind

Existing overhead electrical, see Note 2

Electrical line to transformer, see Note 4

Edge of asphalt, typ.

1006+18.57 As-built MH-17 N=782014.61 E=2922111.02

1009+28.88 As-built MH-18 N=781759.67 E=2922287.38

Existing electrical utility pole

00Existing buried electrical line, see Specifications regarding preservation

WW WC TO LIFT STATION ALIGNMENT

See General Civil Note (60139) casitas, typ.

M

AT

CH

L

M

AT

C H

L

5+

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

WELCOME CENTER AND

CASITAS 1005+00 TO

1009+30

DENVER, CO

24-D-60143

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

Existing ground

8DR25

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber optic

4. See (60192) for Electrical

En d

W W

W C t o lif t st at io n, W et w el l

STATION

1009+30 1010+00 1011+00 1011+71

El. 4442.90

S=-0.00763

S=-0.07909

El. 4444.59

El. 4441.34

WW WC Inv.

.1

4°

'0

5"

S

W W W W W W W

W

F F F F F F F FE E E E E E E E

E

9.67 7.38

Edge of asphalt, typ.

Existing overhead electrical line to be removed, see Note 2

1011+71 End WW WC to lift station Wet well N=781521.17 E=2922331.66

Existing cleanout, see General Notes- Wastewater (60141)

See Note 1

Water line, see Note 5

WW WC to lift station, Replace existing WW in-kind

Existing buried electrical line, see Specifications regarding preservation

See Note 1

Existing overhead electrical pole

WW WC TO LIFT STATION ALIGNMENT

See General Civil Note (60139) casitas, typ.

M A

TC

H L

9+

Buried parallel electrical & fiber optic lines, see Notes 3 & 4

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

D C O

FF

IN

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

WELCOME CENTER AND

CASITAS 1009+30 TO

END

DENVER, CO

24-D-60144

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

WW RV park to lift station (60145)

Existing ground

8DR25

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber optic

4. See (60192) for Electrical

A

TI

O N

STATION

2000+00 2001+00 2002+00 2003+00 2004+00 2005+00 2005+55

S=-0.00421

S=-0.00336 S=-0.00333

B eg in R

V P ar k

W W a lig nm en t A s-bu ilt

M H

-1

.6

En d

R V P ar k

W W a lig nm en t W et w el l

.7

R C P

C l.

in te rs ec tio n

.3

A s-bu ilt

M H

-1

El. 4449.60

El. 4447.50 El. 4449.25 El. 4448.70

Existing grade

RV Park WW Inv.

S S S S S S S S

E

E E

E

E

E

E E

E

E

E

E E E

W

WWWWWWW

WWW

W

W

W

SSSSSSSSSSS

S

S

S

F

F

F

F

F

FFFFFFFFFFF

S

S

S

S

S

S

W

W

W

W

W

E

E

E

E

E

EEE

2000+00 Begin RV Park WW alignment MH-12 As-built N=781004.99 E=2922188.41

2005+54.66 End RV park WW alignment, Wet well N=781540.88 E=2922327.652002+70.31

As-built MH-19 field verify N=781261.99 E=2922272.18

2001+04.79 24" RCP Cl. intersection N=781104.62 E=2922220.88

24" RCP Inv. El.=4451.28

See Note 7

Water line, see Note 5

Buried fiber optic line cont., see Note 3

Casitas, typ.

See Note 1

Edge of asphalt, typ.

See Note 1

Existing buried electrical line, see Specifications regarding preservation

Existing overhead eletrical line to be removed, see Note 2

Existing lift station

Waterline, see Note 5

Parallel electrical and fiber optic line, see Notes 3 & 4

See Note 1

WW force main to WWTP

WW WC to lift station see (60144)

See Note 1

Buried electrical lines, see Note 4

Buried fiber optic line end, see Note 3

WW force main to WWTP, see (60153)

See Note 8

WW RV park to lift station

Edge of concrete

Existing eletrical pole

RV PARK WW ALIGNMENT

45004510

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

RV PARK

DENVER, CO

24-D-60145

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

PLAN

1" = 40'

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber Optic

4. See (60192) for Electrical

5. See (60154) for Water

6. See (60146) and (60147) for RV Park utilities locations

7. Invert elevation unavailable, Contractor to survey

8. Contractor to coordinate abandonment point for existing force main pipe with COR.

8DR25

PROFILE

Vertical scale exaggerated 10X for clarity

E

W

W

W

W

W

S S

S S

S S

S

S

S

S

S S

S

S

S

F F

F F

F F

F

F

F

F

E E

E

E

E

E

E

E

E

E E

E E

E E

E

E E

E

E

E

E E

E

E

E E

E E

EW

W

W W

W W

W

W

W

W

W

W

W

W

W

S S

S S

S

18 19

24" RCP Inv. El.=4451.28

See Note 11

Accessible RV site, see Note 7

Accessible RV site, see Note 8

WW force main to WWTP, see Note 6

See Note 1

Water line, see Note 5

Buried fiber optic line start, see Note 3

Existing cleanout, see General Notes-Wastewater (60141)

Existing buried electrical line

WW RV park to lift station

Parallel buried electrical and fiber optic lines, see Notes 3 & 4

24" RCP

Existing electrical pole

Existing overhead electrical line

Hookups, typ.

see Note 9

Edge of asphalt, typ.

Buried electrical line, see Note 4

2001+04.79 N=781104.62 E=2922220.88

Edge of asphalt, typ.

Existing overhead electrical line to be removed, see Note 2

See Note 10

WW FORCE MAIN TO

WWTP ALIGNMENT

RV PARK GUARD POSTS-CAPS

Point #

Northing

781147.86

781139.07

781096.40

781099.67

781063.06

781067.11

781033.54

781037.17

781008.73

781012.21

780981.57

780984.45

780954.46

780956.55

780918.31

780919.77

780888.73

780889.00

780860.85

780859.76

780806.13

780813.16

780760.40

780751.40

780764.80

780755.80

780777.84

780768.87

780784.87

780776.14

780794.75

780785.88

780833.47

780841.73

780885.50

780889.28

780910.36

780913.71

780927.83

780931.20

780961.17

780966.89

781000.93

781006.05

Easting

2922206.64

2922204.72

2922197.23

2922188.85

2922191.62

2922183.59

2922179.27

2922171.03

2922165.44

2922157.15

2922150.56

2922142.03

2922125.26

2922116.51

2922111.31

2922102.43

2922103.52

2922094.53

2922097.66

2922088.73

2922094.21

2922088.59

2922098.65

2922098.89

2922130.34

2922130.58

2922159.98

2922160.73

2922189.22

2922191.39

2922213.10

2922214.65

2922264.77

2922268.34

2922287.79

2922295.96

2922274.49

2922282.84

2922244.11

2922252.46

2922230.02

2922236.96

2922229.00

2922236.40

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

RV PARK

UTILITY LOCATIONS

DENVER, CO

24-D-60146

PLAN

1" = 20'

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber Optic

4. See (60192) for Electrical

5. See (60154) for Water

6. See (60183) for force main typical detail

7. Contractor will field confirm RV Park utility hookups with COR.

8. See (61601) for typical accessible RV Park utility hookups. Including guard post spacing

9. See (61601) for typical RV connections and guard post spacing.

10. Contractor to coordinate abandonment point for existing force main pipe with

COR.

11. Invert elevation unavailable, Contractor to survey

S

S

S

S

S

S

S

S S

S

S

S

S

S

SS

S

S

S

S

S

S

S

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

Edge of asphalt, typ.

Edge of concrete road, typ.

See Note 1

Water line, see Note 5

See Note 1

See Note 1

Casitas, typ.

Existing overhead electrical line to be removed, see Note 1

Existing buried electrical line, see Specifications regarding preservation

RV park utility hookups, typ.

see Note 9

Existing utility pole, typ.

Proposed WW RV park to lift station

WW force main to WWTP

See Note 10

Existing cleanout, see General Notes- Wastewater (60141)

RV park guard post, typ.

see Note 9

Accessible RV site, see Note 8

Existing overhead electric line

Existing WW WC to Lift Station to be replaced in-kind

Buried electrical line, see Note 4

Existing manhole, typ.

Lift station WW FORCE MAIN TO

WWTP ALIGNMENT

Buried parallel electric & fiber optic lines, see Notes 3 & 4

RV PARK GUARD POSTS-CAPS

Point #

Northing

781666.38

781664.09

781600.32

781597.25

781418.93

781410.83

Easting

2922276.83

2922268.13

2922276.76

2922268.30

2922341.03

2922344.96

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

M H

EK

M

A

TI

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PARTIAL

SITE PLAN

RV PARK

DENVER, CO

24-D-60147

SITE PLAN

1" = 20'

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber Optic

4. See (60192) for Electrical

5. See (60154) for Water

6. See (60183) for force main typical detail

7. Contractor will field confirm RV Park utility hookups with COR.

8. See (61601) for typical accessible RV Park utility hookups.

9. See (61601) for typical RV connections and guard post spacing.

10. Contractor to coordinate abandonment point for existing force main pipe with COR.

W W

W

W

W

W

W

W

W

W

W

W

W

W

E

E

S

S

S

S

S S

S

S

S

W

W

W

W

W

W

W

W

W

W

W W

W

W

E E

E W W

W

3000+00

3002+00 3004+

3006+00

3008+00

3012+00

3018+00

3020+00

3020+57

3000+00 Begin WW Hilltop housing N=781574.63 E=2921511.79

3019+09.36 Waterline crossing N=782163.08 E=2921596.28

1 2

Base/Opus point, see (60137)

SCP4 See (60137)

SCP3 See (60137)

Residential building, typ.

Existing chainlink fence, Remove & replace as directed by COR

Existing waterline

Existing overhead electrical line

Existing commercial building

Existing WW line

Existing manhole, typ.

Existing retaining wall

Existing cleanout, typ.

Edge of asphalt, typ.

Existing WW WC to lift station to be replaced in-kind

Fiber optic line

44404450

44604470

3020+56.92 Begin WW WC to lift station N=782310.42 E=2921594.41

Existing buried electrical line, See Specifications for preservation

HILLTOP HOUSING POINT TABLE

Point #

Northing

781405.71

781521.34

781939.61

781957.82

781836.07

781874.63

782028.69

Easting

2921692.42

2921888.34

2921826.43

2921683.38

2921390.68

2921390.93

2921585.17

Description

Manhole

Manhole

Manhole

Manhole

Manhole

Manhole

Manhole

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D. COFFIN

D. COFFIN

K. PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

HILLTOP HOUSING

DENVER, CO

24-D-60148

PLAN

1" = 50'

A

TI

O N

STATION

3000+00 3005+00 3010+00

S=-0.00200 S=-0.02246

S=-0.05750

El. 4541.46 El. 4540.89

El. 4535.77

El. 4510.00

Existing ground

El. 4504.01

S=-0.16970

S ta rt o f W

W H ill to p H ou si ng

.1

M H

-1

.9

M H

-2

.0

M H

-3

WW Hilltop Housing Inv.

3000+00 Begin WW Hilltop Housing N=781574.63 E=2921511.79

3019+18.31 N=782171.72 E=2921600.31 Waterline crossing

MH-3

MH-1

Edge of asphalt

Existing cleanout

Existing wastewater line

Existing retaining wall

Residential building

Existing chainlink fence, see Note 1

WW Hilltop Housing line

Existing wire gate, see Note 1

Existing electrical pole

Existing overhead electrical line

Existing waterline

Edge of asphalt, typ.

446044

+00

3001+50

3003+00

3004+50

3006+00

3007+

+0

MATCH LINE 3010+00

3000+35.94 Horiz. Δ=79°38'15" N=781598.84 E=2921538.36

3001+18.15 Horiz. Δ=20°57'51" N=781549.03 E=2921603.76

3006+00 Horiz. Δ=17°28'37" N=781599.56 E=2921853.03

3006+61.59 Horiz. Δ=9°29'54" N=781660.72 E=2921845.72

3007+34.02 Horiz. Δ=3°56'37" N=781730.23 E=2921825.37

3008+20.33 Horiz. Δ=31°07'29" N=781811.20 E=2921795.49

3009+13.01 Horiz. Δ=53°00'14" N=781890.64 E=2921836.69

MH-2

HILLTOP HOUSING POINT TABLE

Point #

MH-1

MH-2

MH-3

Northing

781405.71

781521.34

781939.61

Easting

2921692.42

2921888.34

2921826.43

Description

Manhole

Manhole

Manhole

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D. COFFIN

D. COFFIN

K. PELZER

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

HILLTOP HOUSING

3000+00 TO 3010+00

DENVER, CO

24-D-60149

PLAN

1" = 50'

8DR25

NOTE

1. Protect existing features (fencing, gates, etc.) in accordance with Specifications unless otherwise directed by COR.

PROFILE

Vertical Scale exaggerated 10x for clarity

A

TI

O N

STATION

3010+00 3015+00 3020+00 3021+00

.2

M H

-4

.2

M H

-6

.3

M H

-5

.9

En d

W W

H ill to p

H ou si ng

El. 4445.36

.4

C M

P C l.

in te rs ec tio n

.3

W at er lin e cr os si ng

El. 4455.00 El. 4450.35

El. 4464.64El. 4465.76

El. 4467.40

El. 4485.46

El. 4504.01

Existing ground

.5

M H

-7

S=-0.17020

S=-0.02888

S=-0.05641

S=-0.03452

3020+

3010+00

3014+00

+003018+

3020+

3000+00 N=781574.63 E=2921511.79 Begin WW hilltop housing

3019+09.36 Waterline crossing N=782163.08 E=2921596.28

3020+56.92 End WW Hilltop Housing Begin WW WC to lift station N=782310.42 E=2921594.41

MATCH LIN

E

010+00

24" CMP Inv. El.=4471.59

SCP4, see (60137)

Existing wastewater line

MH-5

MH-6

MH-7

MH-4

Edge of asphalt, typ.

Existing electric pole, typ.

Existing overhead eletrical line

Existing waterline

Welcome Center

Cont. Hilltop Housing wastewater line

Existing cleanout, see General Notes- Wastewater (60141)

Fiber optic line, see Note 3

WW WC to Lift Station

Existing buried electrical line

Existing manhole

4420 44

4470 44

Existing retaining wall

3014+27.40 24" CMP Cl. Intersection N=781825.63 E=2921417.72

Bend Sta.=3000+35.94 (WW Hilltop Housing) Δ=79°38'15" N=781,598.84 E=2,921,538.36

3014+20.15 Horiz. Δ=37°06'25" N=781823.01 E=2921424.48

3015+63.61 Horiz. Δ=11°07'39" N=781879.27 E=2921459.44

3016+11.62 Horiz. Δ=31°36'10" N=781891.70 E=2921505.81

3016+94.89 Horiz. Δ=27°14'48" N=781952.21 E=2921563.03

24" CMP Inv. El.=4470.39

HILLTOP HOUSING POINT TABLE

Point #

MH-4

MH-5

MH-6

MH-7

Northing

781957.82

781836.07

781874.63

782028.69

Easting

2921683.38

2921390.68

2921390.93

2921585.17

Description

Manhole

Manhole

Manhole

Manhole

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

D. COFFIN

D. COFFIN

K. PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

HILLTOP 3010+00 TO

END

DENVER, CO

24-D-60150

PLAN

1" = 50'

PROFILE

Vertical scale exaggerated 10X for clarity

8DR25

WW Hilltop Housing Inv.

SCP7, see (60137)

4000+00

MH-8

Begin Hospital Canyon WW alignment N=782396.75 E=2920407.17

4009+75.84

MH-13

N=782722.60 E=2921168.47

4007+57.66

MH-12

N=782759.80 E=2920953.49

4004+64.95

MH-11

N=782566.63 E=2920733.57

4001+29.75

MH-10

N=782526.31 E=2920400.81

Abandon MH-9 N=782406.45 E=2920374.05

4002+61.29 Potable water crossing N=782542.14 E=2920531.39

Existing WW Hospital Canyon to be replaced in-kind

4010+24.20 End WW Hospital Canyon

MH-14

N=782683.40 E=2921196.79

Existing waterline

Waterline (60154)

4010+24

4000+00

00 40

4006+00

+00

NM State Highway 51

Highway 195

Existing overhead electrical line

Existing retaining wall

Edge of road, typ.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

HOSPITAL CANYON

DENVER, CO

24-D-60151

PLAN

1" = 50'

4000+00 Begin WW Hospital Canyon alignment

MH-8

N=782396.75 E=2920407.17

4010+24.20 End WW Hospital Canyon

MH-14

N=782683.40 E=2921196.79

4007+57.66

MH-12

N=782759.80 E=2920953.49

4004+64.95

MH-11

N=782566.63 E=2920733.57

4001+29.75

MH-10

N=782526.31 E=2920400.81

4002+61.29 Potable water crossing N=782542.14 E=2920531.39

4009+75.84

MH-13

N=782722.60 E=2921168.47

SCP7, see (60137)

Existing over head eletrical line, typ.

Water line, see Note 5

Existing water line

Existing cleanout

Existing retaining wall

Existing residential building

Existing edge of asphalt, typ.

Existing edge of gravel road, typ.

NM State Highway 51

+24

4000+00

00 40

4006+00

+00

See Note 6

Abandon MH-9 N=782406.45 E=2920374.05

Existing WW Hospital Canyon to be replaced in-kind

Existing electrical pole, typ.

EL

EV

A

TI

O N

STATION

4000+00 4005+00 4010+00 4010+50

S=-0.01285

S=-0.00238

S=-0.00029

S=-0.00751

S=-0.03163

B eg in W

W H os pi ta l C an yo n M

H -8

.9

M H

-1

.8

M H

-1

.2

En d

W W

H os pi ta l C an yo n

M H

-1

.6

M H

-1

.7

M H

-1

El. 4460.33

El. 4451.92 El. 4449.20

El. 4449.19

El. 4449.72

El. 4456.23

.2

Po ta bl e w at er c ro ss in g

El. 4454.54

Existing ground

WW Hospital Canyon Inv.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

AND PROFILE

HOSPITAL CANYON

DENVER, CO

24-D-60152

PLAN

1" = 50'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber optic

4. See (60192) for Electrical

5. See (60154) for Water

6. Contractor to locate and protect existing historic aqueduct. If new sewer interferes with existing historic aqueduct, proceed as directed by COR.

8DR25

S S

S

S

S

S

S

S

S

1011+71

S

S

S

S

S S

S S

S

S

S S

S

S

5000+00 Begin force main at lift station N=781521.17 E=2922331.66 5009+64.96

End Force Main at

WWTP

N=780734.94 E=2921926.96

W

W

W

W

W W

W W

W

W

W W

W

W

W

W

W

W

5000+15 Horiz. Δ=55°40'28" N=781506.47 E=2922334.66

5000+43.14 Horiz. Δ=32°74'34" N=781486.29 E=2922315.05

5002+71.26 Horiz. Δ=6°46'21" N=781262.65 E=2922270.04

5007+32.26 Horiz. Δ=32°34'45" N=780821.87 E=2922135.52

5008+10.15 Horiz. Δ=29°21'08" N=780769.50 E=2922077.86

See Note 1

Existing overhead electrical line to be removed, see Note 2

Remove and abandon existing WW force main line

WW force main to WWTP, see Note 6

Start of proposed buried fiber optic line, see Note 3

Existing buried electrical line, see Specifications regarding preservation

Waterline, see Note 5

Survey control point N=780775.24 E=2922197.75

EL=4458.62

Existing cleanout, see General Notes - Wastewater (60141)

See Note 1

See Note 1

Existing manhole

Buried electrical line, see Note 4

Buried parallel Electrical and fiber optic lines, See Notes 3 & 4

5004+38.23 24" RCP Cl. intersection N=781103.99 E=2922218.02

24" RCP Inv. El.=4451.28

See Note 7

Existing chainlink fence, remove and replace as directed by COR

WW WC

to lift station line, see (60144)

Existing edge of asphalt

Proposed WW RV parking to lift station

Existing lift station

24" RCP

See Note 1

Existing residential building

Existing edge of concrete

Existing waterline

Existing WWTP

+65

5000+00

00 50

00 50

5007+00

5008+00

+00

Fence crossing

FORCE MAIN WW ALIGNMENT

Existing electrical pole, typ.

EL

EV

A

TI

O N

STATION

5000+00 5005+00 5009+65

S=0.00388

S=0.01625

S= 0.

B eg in F or ce

M ai n at

L ift

S ta tio n

A s-bu ilt

M H

-1

.9

En d

Fo rc e M ai n at W

W

TP

6°

'2 2"

Force Main Cl.

Existing ground

R C P

C l.

in te rs ec tio n

EL. 4445.60

EL. 4447.70EL. 4447.30

EL. 4453.21

EL. 4463.85

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

PEER REVIEWER

A.HADLAND

A.HADLAND

K.PELZER

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-D -6

-R D

-1 .D

W G

LA

S T

S A V

ED

D A

TE

-1 0-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WASTEWATER - PLAN

FORCE MAIN

DENVER, CO

24-D-60153

PLAN

1" = 40'

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber optic

4. See (60192) for Electrical

5. See (60154) for Water

6. See Detail 1 (60183) for force main typical detail

7. Invert elevation unavailable, Contractor to survey

PROFILE

Vertical Scale exaggerated 10x for clarity

8DR25

A

TI

O N

STATION

0+00 1+00 2+00 2+35

EL

EV

A

TI

O N

STATION

2+35 3+00 4+00 5+005+05

S=-0.07143

S=-0.07740

S=-0.62880 S=-0.35000

S=-0.22007

S=0.00000S=0.00000

S=-0.47653

S=-0.20000

S=-0.06212

S=-0.46878 S=0.00000

S=-0.16317

S=-0.26025

S=-0.41442

0+

3+

3+

.1

3+

2+

2+

1+

1+

.5

1+

1+

0+

.8

0+

0+

.8

0+

.6

0+

.7

EL. 4576.0

EL. 4480.0

EL. 4482.8

EL. 4510.0

EL. 4524.0

EL. 4532.8EL. 4532.8

EL. 4532.8

EL. 4544.0

EL. 4548.0

EL. 4550.0

EL. 4563.0

EL. 4563.0

EL. 4573.8

EL. 4565.0

S ta

3+

.6

Ex is tin g st or m d ra in

S ta

4+

.7

Ed ge o f pa ve m en t

S ta

0+

A nc ho r bl oc k

S ta

0+

.8

Th ru st b lo ck

S ta

2+

A nc ho r bl oc k

S ta

3+

.1

Th ur st b lo ck

S ta

1+

.5

Th ru st b lo ck

Existing ground

Existing ground

0+00.80 N=783254.27 E=2920110.45 Begin alignment Paralell line meter valve backflow prevention

0+00 N=783257.86 E=2920133.59 Begin alignment Main Line meter valve backflow prevention

0+53.26 N=783204.73 E=2920137.94 Approx. access road centerline

0+97.55 N=783160.80 E=2920143.51 Approx. access road centerline

1+76.22 N=783082.66 E=2920152.64 Approx. access road centerline

Paralell lines from concrete tank

6" PVC

Ex is tin g st on e va ul t

36" CMP

1+44.32 N=783114.29 E=2920148.51 Overhead power

1+83.38 N=783075.36 E=2920151.95 Overhead power

2+23.16 N=783035.92 E=2920157.13 Overhead power

3+80.68 N=782879.68 E=2920177.15 Existing 24" storm drain pipe

4+53.78 N=782807.05 E=2920185.55 Edge of paved road

455045604570

0+25.55 N=783239.89 E=2920131.57 Thrust block

TC

H L

TA

.6

0 20' 40'10'

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON

STA. 00+00 - 5+05

ALBUQUERQUE, NM

24-512-60156

A

TI

O N

STATION

5+05 6+00 7+00 8+00 9+00 10+00 10+39

S=-0.00829 S=0.01361 S=0.05138

S=-0.07565

S=-0.05000

7+

8+

9+

7+

5+

5+

EL. 4456.9 EL. 4458.0

EL. 4463.1

EL. 4457.4

EL. 4468.0

EL. 4470.0

S ta

5+

.4

S to rm d ra in

S ta

6+

.4

V al ve S ta

6+

.9

V al ve S ta

6+

S tr om d ra in

S ta

7+

.4

S to rm d ra in

S ta

7+

.0

S to rm d ra in

S ta

8+

.4

V al ve S ta

8+

.6

Fi re h yd ra nt

S ta

8+

.8

V al ve

S ta

6+

.4

En d pa ra le ll lin es

S ta

8+

.6

B eg in p ar al el l l in es

S ta

6+

.0

M ar in a La te ra l

Existing ground

4+53.78 N=782807.05 E=2920185.55 Edge of paved road

5+88.40 N=782694.72 E=2920237.34 Existing 36" Storm drain pipe

6+70.49 N=782652.89 E=2920307.98 Valve Main

6+70.90 N=782650.74 E=2920307.19 Valve Paralell

6+80.44 N=782647.51 E=2920316.35 Valve Paralell to main

7+04.41 N=782638.52 E=2920338.83 Existing 36" storm drain pipe

8+80.60 N=782562.74 E=2920497.78 Fire hydrant Thrust block

8+76.46 N=782561.27 E=2920491.99 Valve Paralell line

9+90.22 N=782503.11 E=2920589.78 Overhead power

Gravel road

7+43.04 N=782622.25 E=2920373.87 Existing drain culvert

Winding road alignment

8+99.82 N=782552.51 E=2920514.05 Valve Main line

9+09.44 N=782546.46 E=2920521.61 Overhead power

8+66.65 N=782570.16 E=2920485.97 Begin paralell lines Thrust block

6+80.46 N=782649.98 E=2920317.81 End paralell lines Thrust block

Residential building

4460 44

4470 4470

6+88.01 N=782646.21 E=2920324.35 Marina Lateral Valve Thrust block

5+42.15 N=782719.59 E=2920198.30 Thrust blocks

6+80.20 N=782649.83 E=2920317.42

MATCH LIN

TA 5+04.67

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Fire hydrant locations to be field verified by COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON

STA. 5+05- 10+39

ALBUQUERQUE, NM

24-512-60157

A

TI

O N

STATION

10+39 11+00 12+00 13+00 14+00 15+00 15+33

S=0.06846

S=0.07942

S=0.31217

.3

EL. 4496.0

EL. 4500.8

EL. 4517.4

S ta

.8

V al ve m ai n

S ta

.2

V al ve p ar al el l l in e

S ta

.5

V al ve p ar al el l l in e to m ai n

S ta

.6

Pu m ph ou se b yp as s

S ta

Th ru st b lo ck

Existing ground

6" PVC water line from tanks

6" PVC from concrete tank Main supply alignment To pumphouse

Welcom Center Alignment

Existing Pumphouse

6" Pumphouse bypass line

Pumphouse pump bypass

3.11 89.78 power

14+49.29 N=782211.93 E=2920931.48 Valve Paralell line

14+47.80 N=782214.64 E=2920934.99 Valve Main

14+87.83 N=782176.15 E=2920945.99 Overhead power

14+04.75 N=782255.50 E=2920921.45 Thrust blocks

14+59.68 N=782203.22 E=2920938.26 Pumphouse bypass Thrust block

14+52.35 N=782210.12 E=2920935.79 Thrust block

14+52.51 N=782209.56 E=2920934.36 Valve Paralell line to main

14+52.35 N=782210.12 E=2920935.79 Thrust block

14+70.26 N=782192.90 E=2920940.65 Valve

CH

L

ST

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON

STA. 10+39 - 15+33

ALBUQUERQUE, NM

24-512-60158

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

A

TI

O N

STATION

16+00 17+00 17+80

EL

EV

A

TI

O N

STATION

17+80 18+00 19+00 20+00 21+00 21+27

S=-0.32200

S=-0.25000

S=-0.16000

S=-0.30000

S=-0.04389

EL. 4627.1

EL. 4582.0

EL. 4562.0

EL. 4546.0

EL. 4534.0

EL. 4530.8

S ta

.4

Fi re h yd ra nt

S ta

.1

V al ve

S ta

.5

W ar eh ou se la te ra l

S ta

Th ru st b lo ck

Existing ground

Existing ground

6" PVC tank outlet to Hostipal Canyon alignment

Hilltop Housing alignment

Warehouse lateral field route to existing

6" PVC

NMDOT Permit Required to cross State Highway

20+00.06 N=781477.80 E=2920394.83 Fire hydrant Thrust block

20+29.86 N=781502.39 E=2920387.65 Valve

19+90.22 N=781470.25 E=2920401.14 Warehouse lateral Thrust block

19+81.22 N=781464.39 E=2920406.73 Thrust block

Existing Steel Water Tanks

20+18.36 N=781491.83 E=2920383.09

ATC

H LI

NE

21+34.68

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Fire hydrant locations to be field verified by COR.

6. The contractor shall obtain all necessary NMDOT permits required to complete the project where alignments transect NMDOT right-of-way.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON LOOP

STA. 16+00 - 21+27

ALBUQUERQUE, NM

24-512-60159

A

TI

O N

STATION

21+27 22+00 23+00 24+00 25+00 26+00 26+43

S=-0.08497

.1

EL. 4480.8

EL. 4523.17

EL. 4479.52

Existing ground

6" PVC Hospital Canyon alignment

Edge of road

25+93.17 N=782053.63 E=2920366.61

MATCH LINE STA 21+31.03

C H

L

6+

.4

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E.LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON LOOP

STA. 21+27 - 26+43

ALBUQUERQUE, NM

24-512-60160

A

TI

O N

STATION

26+43 27+00 28+00 29+00 30+00 31+00 31+77

S=-0.06869

S=-0.11962

S=-0.03014 S=-0.01513

S=-0.02576 S=0.00000

.1

.1

.1

.1

.1

.1

EL. 4476.7

EL. 4467.1

EL. 4464.7 EL. 4462.6

EL. 4460.0 EL. 4460.0

S ta

.8

V al ve

S ta

.8

V al ve H os pi ta l C an yo n to

M ai n

Existing ground

E s

Winding road alignment

Residential building

28+83.30 N=782298.36 E=2920402.12 Overhead power

29+75.91 N=782390.19 E=2920411.39 Overhead power

Field route water lines to buildings match downstream pipe

31+61.84 N=782556.90 E=2920478.29 Valve Hospital Canyon alignment

31+74.83 N=782568.25 E=2920484.69 Valve Hospital Canyon alignment to Main

26+91.77 N=782137.30 E=2920314.45 Thrust block

27+66.55 N=782185.71 E=2920371.44 Thrust block

30+50.20 N=782464.35 E=2920415.85

C H

L

6+

.4

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Water service connections to be installed in-kind to replace existing connections to buildings. Exact locations to be approved by COR.

8. Fire hydrant locations to be field verified by COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

HOSPITAL CANYON LOOP

STA. 26+43 - 31+77

ALBUQUERQUE, NM

24-512-60161

A

TI

O N

STATION

32+00 33+00 34+00 34+60

EL

EV

A

TI

O N

STATION

34+60 35+00 36+00 37+00 37+32

S=-0.20774

S=-0.15841

S=-0.25850

S=-0.26250

S=-0.13333

.1

.8

.3

EL. 4626.0

EL. 4504.0

EL. 4512.4

EL. 4518.0

EL. 4576.0

EL. 4618.0

S ta

.7

V al ve

S ta

.6

V al ve

S ta

.5

V al ve

S ta

.1

Th ru st b lo ck

Existing ground Existing ground

37+82.96 N=782187 E=2921088 Valve

6" PVC water line from tanks

6" PVC From Pumphouse to tanks

6" PVC from Tanks Welcome Center Alignment

6" PVC from concrete tank Main supply alignment

To pumphouse

Welcome Center Alignment

Exising Pumphouse

Pumphouse bypass line

45104520

457045

32+06.78 N=781745.73 E=2920744.64 Valve From tanks

32+06.78 N=781747.66 E=2920742.15 Valve To tanks

36+33.61 N=782112.88 E=2920963.04 Valve From pumphouse

36+33.61 N=782110.95 E=2920965.54 Valve To Welcome Center Alignment

Pumphouse pump bypass

36+49.59 N=782125.38 E=2920972.56 Valve Tank bypass Thrust block

W V

37+66.57 N=782180.64 E=2921074.26 Valve

36+63.51 N=782136.45 E=2920981.16

CH

L

.7

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

WELCOME CENTER

STA. 32+00 - 37+32

ALBUQUERQUE, NM

24-512-60163

A

TI

O N

STATION

37+32 38+00 39+00 40+00 41+00 42+00 43+0043+11

S=-0.08328

S=-0.06385

S=-0.11381

S=-0.08317

S=0.00000

.6

.3

.3

.9

EL. 4472.0

EL. 4480.0

EL. 4486.8

EL. 4504.0

S ta

.5

V al ve

S ta

.1

V al ve

S ta

.8

A pp ro x.

L od ge c on ne ct io n

S ta

.1

Fi re h yd ra nt

Existing ground

44+21.44 N=782090.23 E=2921557.30 Valve

41+78.88 N=782140.16 E=2921372.09 Field route to Lodge match existing 34" copper

42+51.18 N=782085.74 E=2921419.68 Fire hydrant Thrust block

37+86.63 N=782191.45 E=2921089.92 Valve

6" PVC water line from tanks

40+65.90 N=782224.70 E=2921297.20 Overhead power

4510Pumphouse

Pumphouse bypass

37+66.57 N=782180.64 E=2921074.26 Valve

37+83.14 N=782188.12 E=2921088.87 Thrust block

42+02.84 N=782121.36 E=2921386.96 Overhead power

44+30.53 N=782097.90 E=2921562.58 Winding Road ali4460

45004510

39+13.49 N=782279.20 E=2921171.29 Thrust block

39+89.59 N=782282.15 E=2921246.96 Thrust block

42+95.99 N=782051.78 E=2921448.92 Thrust block

38+29.32 N=782232.51 E=2921101.63

MATCH LINE STA 37+32.71

TC

H L

3+

1" = 20'

PROFILE

1" = 30' Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Fire hydrant locations to be field verified by

COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-1 1-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

WELCOME CENTER

STA. 37+32 - 43+11

ALBUQUERQUE, NM

24-512-60164

A

TI

O N

STATION

43+11 44+00 45+00 46+00 47+00 48+00 48+61

S=0.00000 S=-0.03333

.8

.7

.7

EL. 4452.0EL. 4452.0

EL. 4456.0

S ta

.8

V al ve

EL. 4453.53

S ta

.4

V al ve

S ta

.5

S to rm d ra in

S ta

.3

H ill to p

H ou si ng al ig nm en t S ta

.2

R es ta ur an t

La te ra l

S ta

.1

V al ve

Existing ground

S ta

.9

V al ve a nd F ir e

H yd ra nt

S ta

.9

V al ve a nd F ir e

H yd ra nt

48+58.84 N=782244.26 E=2921879.05 Valve End Welcome alignment Begin Casitas alignment44+21.44

N=782090.23 E=2921557.30 Valve

Restaurant Lateral Field Route 2" PVC install water meter at building connection

42+49.91 N=782085.74 E=2921417.75 Fire hydrant

44+51.12 N=782113.27 E=2921575.06 Valve

47+99.53 N=782258.07 E=2921821.37 Existing storm drain

44+29.63 N=782096.00 E=2921563.11 Hilltop Housing alignment

44404450

446044704480

43+57.40 N=782046.90 E=2921510.14 Thrust block

46+68.88 N=782287.70 E=2921694.51 Thrust block

45+87.06 N=782236.97 E=2921630.31 Thrust block

44+35.20 N=782099.82 E=2921567.17 Restaurat Lateral Thrust block

48+47.93 N=782247.47 E=2921868.60

Fire Hydrant

CH

LI

+08

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Meter and service connection locations to be field verified by COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

Nemeth, Mark S P.E.

Padilla, Robert S P.E.

Supervisory Civil Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

A M

A R N

ER

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

WELCOME CENTER

STA. 43+11 - 48+61

ALBUQUERQUE, NM

24-512-60165

2023-12-01

R

EV

N O dd ed F ir e

H yd ra nt t o

W el co m e C en te r

A lig nm en t

A

TI

O N

STATION

49+00 50+00 51+00 52+00 53+00 53+76

S=-0.00231

EL. 4452.0

Existing ground

EL. 4450.90

49+00 N=782244.26 E=2921879.05 End Welcome Center alignment Begin Casitas alignment

Fiber optic line, see note 3

Sewer line, see note 5

Existing buried electric line, See specificdations regarding preservation

Burried parallel electric & Fiber optic lines, see notes 3 & 4

Existing overhead electrical line to be removed, see note 2

Casita typ.

48+47.93 N=782246.66 E=2921868.41

TC

H L

3+

.0

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Water service connections to be installed in-kind to replace existing connections to buildings. Exact locations to be approved by COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

Nemeth, Mark S P.E.

Padilla, Robert S P.E.

Supervisory Civil Engineer

A

LW

A

YS

T H

IN

K

S A

FE

TY

SHEET

D

C

B

A

D

C

B

A

B U

R

EA

U O

F R

EC

LA

M

A

TI

O N

U .S

D

EP

A R

TM

EN

T

O F

TH

E

IN

TE

R

IO

R

C A D

S

YS

TE

M

A ut oC A D

4.

2S

LM

S T

EC

H

C A D

F

IL

EN

A M

E

-5

-6

-R

D -1

.D W

G

LA

S T

S A V

ED

D A

TE

-0 3-

LA

S T

S A V

ED

B Y

EL

U

JA

N

R

IO

G R A N

D E

PR

O

JE

C T

EL

EP

H A N

T B U

TT

E

PO

W

ER

A

N D

S

TO

R A G

E D

IV

IS

IO

N

EL

EP

H A N

T B U

TT

E

R

ES

ER

V O

IR

R

EC

R

EA

TI

O

N A

R

EA

H

IS

TO

R

IC

D

IS

TR

IC

T U

TI

LI

TY

R

EP

LA

C

EM

EN

T

WATER - PLAN AND

PROFILE

CASITAS

STA. 49+00 - 53+76

ALBUQUERQUE, NM

24-512-60166

2023-12-01

PLAN

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

R

EV

N O ed F ir e

H yd ra nt t o

W el co m e C en te r

A lig nm en

A

TI

O N

STATION

53+76 54+00 55+00 56+00 57+00 57+65

.7

EL. 4450.0EL. 4450.88

S ta

.1

V al ve a nd m et er

Existing ground

S ta

.5

V al ve a nd F ir e

H yd ra nt

58+00 N=781537.33 E=2922330.40 End Casitas alignment begin RV park alignment

57+62.11 N=781539.90 E=2922329.92 Valve Water meter

55+37.84 N=781760.45 E=2922289.27 Thrust block

Fiber optic line, see note 3

Sewer line, see note 5

Existing buried electric line, See specificdations regarding preservation

Existing overhead electrical line to be removed, see note 2

Casita typ.

54+05.54 N=781869.46 E=2922214.29

CH

L

1" = 20'

PROFILE

Vertical scale exaggerated 10X for clarity

NOTES

1. See (60192) for Electrical pad description

2. See (60191) for Electrical demolition

3. See (60205) for Fiber

4. See (60192) for Electrical

5. See (60141) for Sewer

6. Thrust or Anchor block control at all bend and tee fittings and slope changes noted on drawings.

7. Water service connections to be installed in-kind to replace existing connections to buildings. Exact locations to be approved by COR.

8. Meter location to be field verified by COR.

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL

E. LUJAN

E. LUJAN

R. BERNAL

Nemeth,…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .