Attachment #2 Site Plans - Floor Plans.pdf
PDF 3 MB Posted
- Solicitation number
- MF245820079
- Issued by
- Woodbury County, Sioux City, Iowa
About this file
This document comprises site plans and floor plans for the Installation Notification and Warning System (INWS) and Fire Alarm System at the 185th Air Refueling Wing in Sioux City, Iowa, prepared for the Iowa Department of Public Defense. The plans detail the communication infrastructure, fire detection devices, mass notification systems, and power distribution across 25 buildings at the Air National Guard facility. The drawings specify device locations with candela ratings (ranging from 15cd to 240cd), power panel locations, antenna placements, ground bar installations, and conduit routing for both the INWS and fire alarm systems. The plans were prepared as of October 18, 2017, with revisions through June 25, 2018, and include detailed layouts for multiple floors and mezzanines within individual buildings, as well as site plan sheets showing external antenna towers, poles with extended mass notification systems, and trenched power conduit installations connecting various buildings across the facility.
The technical documentation includes comprehensive communication plans for Buildings 220, 234, 235, 240, 241 (three sheets plus floor two), 251, 252, 253, 254, 261 (two sheets), 265, 269, 278, 280 (including mezzanine), 283, 284, 286 (two sheets), 311, and site plans for the overall facility. Equipment specifications referenced throughout the plans include UVRI units, SP40S-D and SPB-160 devices, SP4-RMX units, and various FCPS and PS series power supplies. The plans note special conditions such as Class I Division 1 hazardous areas in certain rooms and device modifications made at the base's request. These plans serve as the technical reference documentation for the fire preventive maintenance services contract, enabling bidders to understand the scope of systems requiring ongoing inspection and maintenance across the facility.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Attachment #1.pdf | ||
| Attachment #2.pdf | ||
| Attachment #3.xlsx | XLSX spreadsheet | |
| Attachment #3 Inspection listing and Frequencys.xlsx | XLSX spreadsheet | |
| Attachment #1 Sioux City Specifications and Inspection Criteria.pdf | ||
| Attacment #6-Sioux City Fire questions and answer responses.docx | DOCX document | |
| Attachment #5 RFQ- Sioux City Fire.pdf | ||
| 1234607-event.pdf | ||
| Attachment #4 - Section 889 Form(blank).pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A13 15cd
A14 30cd
A10 15cd
A11 15cd
A06 15cd
A05 75cd
B08 30cd
A04 15cd
A12 15cd
B07 15cd
B11 15cd
B13 15cd
B12 75cd
B09 15cd
A01 75cd
A02 75cd
A03 15cd
A09 15cd
A08 15cd
POWER PANEL
PNL: LA-2 CB: 50
FACP
LOC
FACP
LOC#1
UVRI, SP40S-D,
SP4-RMX, PS-8-LP
LOC
LOC#2
B04 15cd
B05 15cd
B06 15cd
C08 15cd
C07 15cd
C03 75cd
C04 15cd
D10 15cd
D11 15cd
D07 15cd
D09 15cd
D08 15cd
D04 15cd
D05 15cd
D06 30cd
C01 75cd
C02 75cd
D03 15cd
D12 75cd
D13 15cd
D02 15cd
D01 30cd
C06 75cd
C05 15cd
B02 15cd
B03 15cd
ACU ANTENNA
6x6 J-BOX LPD &
GROUND BAR
GROUND BUILDING STEEL
B10
A07
OC
OC
OCOC
OC
OC
OC
OC
PA
PA SYSTEM
A
CU
/N
AC
B01 15cd
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B220FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 220, FLOOR 1
6x6 J-BOX LPD
& GROUND BAR
GROUND ROD
& BOX
ACU ANTENNA
FA
C P
ACU/NAC
POWER PANEL
PNL: LP2 CB: 40
UVRI, SP40S-D,
SP4-RMX, FCPS-24FS8
LO
C
LOC#1
FACP
LO
C
LOC#2
A01 75cd
A02 75cd
A04 75cd
A03 75cd
A05 75cd
B01 75cd
B02 15cd
C01 15cd
C02 15cd
C03 15cd
C04
OC
OC
OC
FC
FC
PA SYSTEM
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B234FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/16" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 234, FLOOR 1
PA SYSTEM
A
CU
/N
AC
LO
C
LO
C
UVRI, SP40S-D,
SP4-RMX, FCPS-24FS8
LOC#1
LOC#2
FA
C
P
COMM
COMM
C04 75cd
C01 75cd
D07 15cd
C02 75cd
D08 15cd
D09 15cd
D02 15cd
D03 15cd
MECH
D05 15cd
D01 30cd
D04 30cd
C05 75cd
D06 75cd
FACP
A01 75cd
A02 15cd
A03 15cd
A04 15cd
A06 15cd
A08 15cd
A07 15cd
A09 15cd
B01 30cd
B02 15cd
B07 15cd
B06 75cd
B08 30cd
B03 30cdB04
15cd
B05 15cd
MEZZANINE
STORAGE
MEZZANINE
STORAGE
POWER PANEL
PNL: ISO CB: 14
6x6 J-BOX LPD &
GROUND BAR
GROUND ROD & BOX
ACU ANTENNA
HC
HC
OC
OC
OC
OC
OC
HC HC
A05
PA
PUBLIC ADDRESS AMP
C03 15cd
SEE NOTE 1
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B235FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 235, FLOOR 1
NOTES:
1. DEVICE WAS CHANGED TO STROBE ONLY AT REQUEST OF BASE.
LO
C
6x6 J-BOX LPD &
GROUND BAR
GROUND ROD & BOX
ACU ANTENNA
FACP LOC
B01 240cd
A01 15cd
A03 15cd
A04 15cd
A05 15cd
A07 15cd
A08 15cd
A06 15cd
CLASS 1 DEV 1 DEVICES
UVRI
LOC#2
LOC#2
FACP
A02
HCHC
OC
HC
PA
PUBLIC ADDRESS AMP
B02
SP40S-D, SP4-RMX,
FCPS-24FS8
POWER PANEL
PNL: LLC CB: 10 & 12
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B240FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/16" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 240, FLOOR 1
1. ROOMS 104 IS CONSIDERED A CLASS 1, DIVISION 1 AREA
B01 240cd
CLASS I DEV 1 DEVICES
A08 15cd
A05 177cd
A07 15cd
A04 75cd
LOC
A03 30cd
OC
HC
PAINT
BOOTH
OC OC
A06
LOC#4
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B241FL1-SH1-03
10/18/17
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
BUILDING 241, FLOOR 1, SHEET 1
NOTES:
1. ROOMS 102 AND 110 ARE CONSIDERED CLASS 1, DIVISION 1 AREAS
SH1
SH2 SH3
CLASS I DEV 1 DEVICES
D01 240cd
A02 95cd
A01 95cd
HC HC
C08 15cd
C06 15cd
C07 95cd
C09 15cd
C05 15cd
C04 15cd
C03 15cd
C02 15cd
C01 75cd
E07 15cd
E08 15cd
E03 15cd
E01 75cd
E02 15cd
E04 75cd
E05 15cd
OCOC
HC
F08 75cd
LOC
FA
C
P
LO
C
F07 15cd
MECH
PAINT
BOOTH
F09
OC
LOC#2
LOC#3
E06
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B241FL1-SH2-03
10/18/17
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
BUILDING 241, FLOOR 1, SHEET 2
OCOC
COMM PATH FROM 2ND FLOOR07
d
G02 115cd
G03 95cd
G04 95cd
G01 95cd
H05 30cd
G06 30cd
H03 115cd
H01 30cd
H02 15cd
H04 15cd
H06 75cd
G05 15cd
MEZZANINE
STORAGE
OCOC
POWER PANEL
PNL: EL2 CB: 10 & 12
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B241FL1-SH3-03
10/18/17
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
BUILDING 241, FLOOR 1, SHEET 3
F02
F04 15cd
F01 15cd
F03 15cd
F05 75cd
F06 15cd
LOC
SP40S-D, SPB-160,
(2) SP4-RMX, (2) PS-8-LP
LOC#3
COMM PATH TO 1ST FLOOR
6x6 J-BOX LPD & GROUND BAR
ACU ANTENNA
GROUND BUILDING STEEL
PA
PUBLIC ADDRESS AMP
UVRI
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B241FL2-03
10/18/17
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 241, FLOOR 2
FA
C
P
LO
C
6x6 J-BOX LPD
& GROUND BAR
GROUND CABLE
ACU ANTENNA
GROUND POINT
UVRI, SP40S-D, SP4-RMX
LOC#2
FACP
A C
U
POWER PANEL
PNL: MDP1 CB: 39
LO
C
LOC#1
A01 75cd
A02 15cd
A03 15cd
A05 15cd
A06 30cd
A04
OC
HC
OC
PA
PUBLIC ADDRESS AMP
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B251FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/16" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 251, FLOOR 1
A02 95cd
A09 95cd
A08 15cd
A07 15cd
A06 15cd
A04 15cd
A05 15cd
A03 15cd
C04 30cd
C05 15cd
C03 95cd
B05 95cd
B04 15cd
LOC
LO
C
A
CU
/N
AC
FA
CP
POWER PANEL
PNL: E CB: 23
UVRI, SP40S-D,
SP4-RMX, FCPS-24FS8
FACP
RF GROUND BAR
CONDUIT SLEEVE FOR RF CABLES
FC
FC
FC FC
FC FC
FC
FC
FC
OC
OC
OC OC
OC
OC
C02 30cd
C01 30cd
B02 95cd
B01 95cd
ACU ANTENNA
LOC#1
LOC#2
B03 95cd
OC
C06 75cd
C07 75cd
A01
PA
PUBLIC ADDRESS AMP
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B252FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 252, FLOOR 1
MEN'S RR
WOMEN'S
LOCKERS
/ RR
VEST
AGS
EQUIPMENT
STORAGE
COMPUTER
STATIONS
VEST
WSC STORAGE TRAINING
AGS LOCKER
COMM
MECHANICAL/
ELECTRICAL
AUDITORIUM
JAN
GCCNSHOP
GCCN
VAULT
B08 15cd
HC
HC
OC
OC
OC
A06 15cd
A05 15cd
A08 15cd
B02 30cd
A11 30cd
B05 75cd
B06 75cd
B09 30cd
B10 15cd
B04 15cd
A10 15cd
A09 15cd
B03 75cd
A04 75cd
A03 75cd
C09 15cd
C08 30cd
C11 15cd
C06 30cd
C04 75cd
C05 75cd
C07 30cd
C01 75cd
C02 15cd
A01 15cd
B01 75cd
A02 15cd
C03 15cd
A07 30cd
A12 15cd
C12 75cd
6x6 J-BOX LPD &
GROUND BAR
FACP
POWER PANEL
PNL: LC CB: 11
FACP
A
CU
/N
ACUVRI, SP40S-D,
(2) SP4-RMX, FCPS-24FS8
LOC
LO
C
ACU ANTENNA
LOC
LOC#1
A13
C10
PA
PUBLIC ADDRESS AMP
B07 15cd
LOC#2
LOC#3
SEE NOTE 1
GROUND BAR
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B253FL1-03
10/18/17COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 253, FLOOR 1
1. DEVICE WAS CHANGED TO STROBE ONLY AT REQUEST OF BASE.
A
CU
/N
AC
COMM
6x6 J-BOX LPD
& GROUND BAR
GROUND CABLE
ACU ANTENNA
GROUND POINT
LOC
LOC
FA
CP
LO
C
MECH
MECH
ELEC
COMM
STORAGE
STORAGE
STORAGE
STORAGE
B02 15cd
B04 15cd
B01 30cd
C01 15cd
C02 15cd
E10 15cd
E06 15cd
E09 30cd
E11 30cd
E04 15cd
B05 30cd
A09 15cd
B13 15cd
F05 15cd
F04 15cd
F03 15cd
F01 15cd
B06 15cd
B08 15cd
B09 30cd
A13 15cd
A12 15cd
A10 15cd
A11 75cd
A08 15cd
A06 30cd
A03 30cd
A05 15cd
A04 15cd
A02 30cd
B07 75cd
OC OC
OC
OC
DRYING TOWER
C06 15cd
C08 15cd
C10 15cd
C05 75cd
C07 30cd
C09 30cd
C04 15cd
B10 30cd
B11 15cd
B12 30cd
B03 15cd
C03 75cd
E01 30cd
E02 75cd
G01 15cd
G02 15cd
E03 75cd
E05 30cd
E08 30cd
E07 30cd
E12 30cd
F02 15cd
F07 75cd
F08 15cd
G03 75cd
F09 15cd
F11 15cd
F10 75cd
LOC#2
FACP
LOC#3
LOC#1
SP40S-D, SPB-160,
(2) SP4-RMX, (2) FCPS-24FS8
INWS CIRCUIT "J"
J01 15cd
J03 15cd
J06 75cd
J08 75cd
J07 15cd
J05 75cd
J02 75cd
J04 75cd
BSU ANTENNA
GROUND POINT
(8) 4" ANTENNA CABLE
CONDUITS TO ROOF
RADIO CABINET
BSU
BSU
SPB-80/4
FO PATCH PANELS/ NIPR RACK
MEDIA CONVERTERS FOR AUDIO
& STROBE ARE LOCATED IN RACK
FIBER CONNECTION RM01 & RM48
MEDIA CONVERTERS FOR AUDIO &
STROBE WILL BE LOCATED IN RACK
FIBER CONNECTION RM01 & RM48
CAT6 CABLE FOR AUDIO
& CONTROL TO TRANCEIVER
A01
F06
PA
PA SYSTEM
A07 15cd
UVRI
POWER PANEL
PNL: LA CB: 31 & 33
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B254FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 254, FLOOR 1
NOTES:
1. AUDIO/STROBE CONTROL WAS ROUTED FROM ACU TO THE AREA COVERED BY
CIRCUIT "J" VIA EXISTING FIBER. AUDIO WAS CONVERTED TO/FROM FIBER
USING (1) TX AND (1) RX MEDIA CONVERTERS. STROBE CONTROL WAS
HANDLED IN THE SAME FASHION
2. AUDIO/STROBE CONTROL WAS CONVERTED, ROUTED TO SPB-80/4 AND
DISTRIBUTED TO MNS SPEAKER/STROBE WITHIN THE AREA COVERED BY
CIRCUIT "J"
(4) 4" CONDUITS STUBS IN CEILING
A05 177cd
A04 177cd
A03 177cd
J08 177cd
J05 177cd
J02 177cd
E03 177cd
B06 75cd
B04 30cd
B05 30cd
B03 75cd
B02 75cd
C11 75cd
HC HC
C08 15cd
C09 75cd
C10 15cd
FACP LOC
A02 15cd
A01 15cd
B09
B08 15cd
B07 15cd
C07
OC
OC
OC
C04 15cd
C05 15cd
C06 30cd
C02 75cd
C03 75cd
C01 75cd
E06 75cd
E02 95cd
E05 15cd
E07 75cd
E08 75cd
E01 75cd
E04 75cd
OC
OC
OC
OC
F05 95cd
F06 15cd
F04 30cd
F07 15cdF03
30cd F01 30cd
F02 75cd
F09 75cd
F08 75cd
MECH
MECH
X-RAY
G01 15cd
PHOTO LAB
G05 30cd
G06 15cd
G08 15cd
G10 15cd
G09 75cd
G07 15cd
G04 30cd
G02 15cd
CABLE TRAY
CABLE TRAY
G03
J01 95cd
J07
H03 15cd
H04 30cd
H02 15cd
H01 15cd
H05 75cd
H07 75cd
H09 75cd
H10 15cd
H08 15cd
H11 75cd
H12 15cd
J04 15cd
J06 15cd
COMM
COMM
LO
C
LO
C
LOC#3
LOC#2
LOC#1
H06 15cd
J03 15cd
B01 15cd
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B261FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 1/16" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 261, FLOOR 1
K12
L02 15cd
N02 15cd
P10 15cd
P01 15cd
L06 15cd
ACU/ NAC
N01 15cd
POWER PANEL
PNL: ELK4S CB: 19, 21 & 23
UVRI, SP40S-D, (2) SPB-160,
(2) SP4-RMX, (4) FCPS-24FS8
(4) 4" CONDUITS STUBS IN FLOOR
COMM
STORAGE
LOC
LOC#5
LOC#4
COMM
COMM
K07 15cd
K09 15cd
K06 15cd
K05 15cd
K03 15cd
K04 15cd
K02 15cd
K08 75cd
STORAGE
K10 75cd
K11 15cd
K01 75cd
L08 30cd
L09 30cd
L07 30cd
L1015cd
L04 30cd M04
15cd
M01 15cd
M03 15cd
M02 15cd
L01 15cd
P04 75cd
K13 15cd
L05 15cd
L03 15cd
P05 15cd
P07 15cd
P06 15cd
P08 30cd
P03 30cd
P02 75cd
N09 15cd
N08 75cd
N07 15cd
N06 15cd
N03 15cd
N04 15cd
N05 30cd
M05 15cd
M06 75cd
M07 30cd
M08 15cd
M09 15cd
M10 30cd
M11 30cd
P09 15cd
70' ANTENNA TOWER
ACU ANTENNA
TOWER PADCABLE ENTRY POINT
ANTENNA CABLE GROUND POINT
LOC
PA
PA SYSTEM
HC
HC
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B261FL2-03
10/18/17
COMMUNICATION PLAN
SCALE: 1/16" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 261, FLOOR 2
UVRI ANTENNA
LOCATED ON ROOF ABOVE
ELECTRICAL ROOM
WEATHER HEAD
ROOF ENTRANCE
FOR RF CABLES
FACP
FA/MNS
UVRI
POWER PANEL
PNL: LPH CB: 30
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B265FL1-01
04/01/19
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 265, FLOOR 1
NOTES:
1. UVRI IS LOCATED ABOVE DOOR IN RM 198.
A07
A05 15cd
A04 15cd
A10 15cd
A11 15cd
A13 15cd
A15 15cd
A16 15cd
A09 30cd
A08 30cd
C13 15cd
C12 15cd
C11 30cd
C10 30cd
C08 15cd
E10 15cd
E08 30cd
F08 30cd
F07 30cd
B15 15cd
B06 15cd
E07 15cd
F06 15cd
F04 15cd
F03 15cdE06
15cd
F02 75cd
E05 30cd
E04 15cd
C01 15cd
C02 15cd
C03 15cd
C04 15cd
B01 15cd
B03 15cd
B05 15cd
B10 15cd
B12 15cd
B14 15cd
B13 15cd
B11 15cd
B09 30cd
B08 15cd
A02 75cd
B04 15cd
B07 15cd
A01 15cd
A06 15cd
A12 15cd
A17 15cd
B02 15cd
ACU/NAC
MECH
COMM
COMM
COMM
F11 15cd
F10 15cd
F12 15cd
F09 15cd
E09 15cd
E01 30cd
FA
CP
LO
C
6x6 J-BOX LPD
& GROUND BAR
GROUND ROD
& BOX
ACU ANTENNA
C05 30cd
C06 15cd
C07 15cd
C09 15cd
B16
E12 30cd
E11 15cd
E02 15cd
E03
F05 15cd
F01 15cd
A14 A03
UVRI, SP40S-D, SPB-160,
SP4-RMX, (2) FCPS-24FS8
POWER PANEL
PNL: LB1A CB: 25 & 27
OC
PA
PUBLIC ADDRESS AMP
LOC#1
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B269FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 269, FLOOR 1
70' TOWER
TOWER PIER
HC
HC
OC
OC
OC
OC
A02 15cd
A08 15cd
A10 15cd
A06 75cd
OC
A11
A07 15cd
A04 15cd
A03 15cd
A01 30cd
A09 15cd
A05 30cd
C07 177cd
C06 75cd
B02 177cd
B03 75cd
B04 177cd
B01 95cd
C04 177cd
C05 75cd
C03 75cd
MECH
COMM
ELEC
FACP
A
CUPOWER PANEL
PNL: LPE-1 CB: 22
LOC
LOC
MECH
LOC#1
LOC#2
C02 15cd
C01 75cd
UVRI, SP40S-D,
SP4-RMX, PS-8-LP
(3) 4" CONDUITS TO COMM RM
ACU ANTENNA
GROUND POINT
(3) 4" CONDUITS TO COMM RM
OC
OC
PA SYSTEM
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B278FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 278, FLOOR 1
A02
A04 15cd
C03 75cd
C04 30cd
D05 15cd
D06 15cd
D07 15cd
D08 30cd
D02 75cd
HC
HC
A01 15cd
A05 15cd
A08 30cd
A09 75cd
A11 15cd
A12 15cd
A06 15cd
A10 15cd
A07 30cd
C05
C01
B07 75cd
B06 30cd
OC OC
B02 30cd
B04 135cd
B05 135cd
B03 135cd
E01 135cd
G04 95cd
B01 30cd
HC
A
CU
/N
AC
VAULT
D04 75cd
C02 15cd
A13
FACP LOC
OC
A03 75cd
G02 75cd
G01 75cd
E04 75cd
E02 135cd
E03 75cd
6x6 J-BOX LPD &
GROUND BAR
GROUND ROD & BOX
ACU ANTENNA
LOC
LOC#2
LOC#1
UVRI, SP40S-D, SPB-160,
SP4-RMX, (2) FCPS-24FS8
SEE MEZZ DWG
SEE MEZZ DWG SEE MEZZ DWG
SEE MEZZ DWG
SEE MEZZ DWG
POWER PANEL
PNL: LC CB: 39 & 41
PA
PUBLIC ADDRESS AMP
2" CONDUIT TO ABOVE MEZZ
SEE MEZZ DWG
G03 75cd
HC
HC
D01 30cd
D03 30cd
CIRCUITS B, E, & F TO MEZZ
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B280FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 280, FLOOR 1
F04 75cd
F05 75cd
F03 75cd
F06 75cd
F01 75cd
F02 75cd
(P) B04-B05
(P) B06(P) B07 (P) B01-B03
(P) E01
(P) E03-E04
2" CONDUIT TO 1ST FLR
RM 200 HALLWAY
(P) E02
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B280MEZZ-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 280, MEZZANINE
FA
CP
LO
C
A
CU
/N
AC
HC HC
OC
A09 15cd
A08 30cd
A05 15cd
A04 15cd
A07 15cd
A03 15cd
A02 15cd
A06 15cd
STORAGE
MECH
BATT RM
B02 95cd
OC OC
C01 75cd
C02 75cd
C03 75cd
B01 75cd
OC
A01
HC
HC
6x6 J-BOX LPD &
GROUND BAR
GROUND ROD & BOX
ACU ANTENNA
POWER PANEL
PNL: A CB: 28
UVRI, SP40S-D,
SP4-RMX, PS-8-LP
LOC#1
B03 75cd
B04 75cd
SEE NOTE 1
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B283FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 283, FLOOR 1
NOTES:
1. SPEAKER/STROBES WITHIN RM 119 WERE INSTALLED AND THEN
LATER REMOVED WHEN IT WAS DETERMINED THAT THIS ROOM IS A
CLASS I, DIVISION 1 AREA.
A11
A10 15cd
A09 15cd
OC
OC
HC
OC
OC
OC
OC
OC
D08 115cd
C08 75cd
C09 75cd C06
75cd
C10 15cd
A08 15cd
HC
A06 15cd
A05 15cd
A07 15cd
A12 15cd
B04 30cd
B02 15cd
B05 30cd
B06 15cd
B03 15cd
B07 30cd
B08 30cd
A04 30cd
A01 15cd
A03 15cd
B09LOC
FACP
A02 15cd
C01 15cd B01
15cd
C03 30cd
C02 15cd
C04 75cd
C05 75cd
D02 30cd
D03 15cd
MECH AREA
OUTDOOR
MECH
COMM
POWER PANEL
PNL: NC CB: 10
ACU/NAC
ACU & NAC
LOC#1
12X12 J-BOX LPD
& GROUND BAR
GROUND CABLE
BSU ANTENNA
GROUND POINT
ACU ANTENNA
BSU
BSU
LOC
LOC#2
D09 95cd
D05 75cd
D01 15cd
PA EQUIPMENT
LOC
LOC#3
D04 15cd
D06 75cd
D07 75cd
C07 75cd
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B284FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 284, FLOOR 1
MECH
HOSE
E01 95cd
C09 95cd
C07 15cd
C03 15cd
B01 15cd
HC HC
B04 15cd
B06 15cd
LO
C
C08 15cd
B07 15cd
A06 15cd
A02 15cd
C05 15cd
C04 15cd
C06 15cd
B05 30cd
C02 75cd
A01 75cd
MECH
A05 30cd
C01 15cd
A09 75cd
A08 75cd
B10 115cd
A07 75cd
A04 15cd
STORAGE
B08 75cd
A03 75cd
B11 15cd
A
CU
/N
AC
UVRI, SP40S-D, SPB-160,
(2) SP4-RMX, (2) PS-8-LP
B02
FA
CP
LO
C
2" CONDUIT RISER
TO 2ND FLOOR
6x6 J-BOX
LOC#2
LOC#3
6x6 J-BOX LPD &
GROUND BAR
4" RISER FOR
ANTENNA CABLE
POWER PANEL
PNL: ELC CB: 21 & 23
GROUND BAR
B09 15cd
A10 15cd
B03 15cd
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B286FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 286, FLOOR 1
E02 E04 E05 E06 E07 E08
F04 F05 F06 F07 F08 F09
F03 15cd
OC OC FCFC
HC
HC
F01 15cd
MECH
F10 30cd
E09 15cd
F12 30cd
2" CONDUIT RISER
FROM 1ST FLOOR
LO
C
LOC#1
F13 15cd
F02 15cd
E03 15cd
F11 15cd
ACU ANTENNA
PA
PUBLIC ADDRESS AMP
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B286FL2-03
10/18/17
COMMUNICATION PLAN
SCALE: 3/32" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 286, FLOOR 2
NOTES:
1. SLEEPING QUARTERS ARE MNS SPEAKER ONLY
FACP
ACU/NAC
A06 75cd
A05 75cd
A03 75cd
A01 75cd
A02 75cd
LO
C
6x6 J-BOX LPD
& GROUND BAR
ACU ANTENNA
UVRI, SP40S-D, SP4-RMX
LOC#1
POWER PANEL
PNL: L1M2 CB: 24
GROUND POINT
RAMP
LOADING DOCK
A04
PA
PA SYSTEM
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-B311FL1-03
10/18/17
COMMUNICATION PLAN
SCALE: 1/8" = 1' (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
BUILDING 311, FLOOR 1
(P) POLE# 1
46' EXT-MNS
(P) POLE# 2
46' EXT-MNS
INSTALLED 1-1" SCH40 PVC CONDUIT (POWER)
TRENCHED FROM POLE TO BLDG. 282.
INSTALLED 1-1" SCH40 PVC CONDUIT
(POWER) TRENCHED FROM POLE TO
BLDG. 221
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-SITEPLAN-SH1-03
9/22/17COMMUNICATION PLAN
SCALE: NTS (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
SITEPLAN, SHEET 1
(P) POLE# 3
46' EXT-MNS
INSTALLED 1-1" SCH40 PVC CONDUIT (POWER)
TRENCHED TO AN EXISTING POWER CONDUIT
RUNNING TO BLDG 240.
(P) POLE# 4
46' EXT-MNS
INSTALLED 1-12"X12" HANDHOLE INTO
EXISTING POWER CONDUIT RUNNING TO
BLDG. 311. INSTALLED 1-1" SCH80 PVC
CONDUIT (POWER) TRENCHED FROM
NEW POLE TO HANDHOLE.
- OF -
COMMUNICATION PLAN
AS NOTED
185ARW-INWS-SITEPLAN-SH2-03
9/22/17COMMUNICATION PLAN
SCALE: NTS (ARCH D)
INSTALLATION
NOTIFICATION
AND
WARNING SYSTEM
(INWS)
SIOUX CITY, IA
SITEPLAN, SHEET 2
987654321 6.4 7.4
DINING
HALL - D1
SERVICE
LINE - D1
KITCHEN -
D2
DRY
GOODS/
COOLER -
D6/D7
DINING
MANAGER
- B6
MAIN
WATER - I6
MAIN
ELEC. - I6
SERVICES
FLIGHT
STORAGE
GARAGE -
B11
UTC - H11
INFASTRUCTURE/
WIRELESS
SHOP - H5
TRAINING/
CONFERENCE/
COMPUTER
CLASS
ROOM - H3
PPE
TRAINING
STORAGE -
H16
DISH
WASH - D3
CUSTODIAL
- D4
SECURE
STORAGE
CRYPTO -
H12
BASE
SUPPORT
(SCXS) -
H10
K.O.M. - H9
RECORDS
STAGING &
STORAGE -
H13
MEDIA
STORAGE -
H15
INFORMATION
SUPPORT -
H14
INFORMATION
SUPPORT -
H14
PLANS - H8
- H8
SERVICES
FLIGHT
ADMIN.
SUITE - B7
BREAKROOM/
VENDING -
I3/I4
OFFICE -
H7
N.O.W. &
C.S.C. -
H6/H7
VESTIBULE
- I8
CHIEF
STAN. - H2
COMMANDER
- H1
OPERATIONS/
PLANS/
RESOURCE
- H4
TRAINING
& TESTING
- B2
COMPUTER
LAB - B3
KITCHEN
RESTROOM
- D5
KITCHEN
RESTROOM
- D5
CONFERENCE/
MEETING -
A3
COAT
STORAGE -
D1
OIC - C1
NCOIC - C2
COMM. - C5
ARCHIVAL/
STORAGE -
C4
MULTI
MEDIA
STUDIO -
C6
ADMIN/
PERSONNEL
- C3
MEDICAL
ADMINISTRATOR
- E6
SARC -
G2-4
1ST
SERGEANT
- E2
COMMANDER
- E1
MEDICAL
READINESS
- F4
2ND ELEC.
- I6
ADMIN/COPY
- F7
MENTAL
HEALTH -
F5
GROUP
SUPERINTENDENT
- E7
DRILL &
TRAINING
AREA - A4
HONOR
GUARD
STORAGE -
A5
BREAKROOM
- G13
JANITOR -
I5
MEDICAL
STORAGE -
G12
HEALTH
SERVICES
ADMIN - E5
EQUIPMENT
STAGING -
G10
DENTAL
OFFICE -
F2
OPTOMETRY
EXAM - G3
OPTOMETRY
OFFICE -
E10
UNISEX
RR - F8
UNISEX
RR - F8
NURSING
SERVICES
- F3
PUBLIC
HEALTH -
E13
BEE
OFFICE -
E11
PHYSICIANS
OFFICE -
E8
AERO-MEDICAL
- E12
IMMUNIZATION
- G7
FLIGHT
NCOIC - A2
FLIGHT
COMMANDER
- B1
SERVICES
NCOIC - B4
FLIGHT
CHIEF - A1
TRANSIENT
LODGING -
B9/B10
100b
TRANSIENT
LODGING
SUPERVISOR
- B8
RESOURCES
MANAGER
- B5
JANITOR -
I5
MEN'S
RESTROOM
- I1
LACTATION
- I2
132B
WOMEN'S
RESTROOM
- I1
SHOWERS
- I1
132A
ADMINISTRATIVE
ADMISSION
OFFICE -
E9
PATIENT
WAITING -
G1
100a
OFFICE
LABORATORY
- G11
CLINICAL
LABORATORY
- F1-A
LAB
TOILET -
F1-B
DENTAL
X-RAY - G5
DENTAL
EXAM -
G4-2
EXAM -
G2-2
EXAM -
G2-1
PUBLIC
HEALTH -
G9
EXAM -
G2-3
AUDIO
TESTING -
G6
DENTAL
EXAM -
G4-1
TRAINING
& TESTING
- E3
CONFERENCE/
MEETING -
E4
191B
188A
199A
102B
102A
107 106
108 109
142B
168169
185B
185E
185D
A
C
B
B
A
A
B
B
185A
A
A
BEE LAB -
G8
MAIN
DEMAR - I7
9.18.3
132A
131A
VESTIBULE
- I8
196A
B
B
3.8
199C
199D
LOBBY/
CIRCULATION
- I8
6.3 6.8 7.93.62.72.52.2
191C
142A
188B
188C
188D
B
A
B
SHOWERS
- I1
131A
F
M11
F
M12
F
M16
F
M19
F
M01
F
M02
F
M03
F
M05
F
M06
F
M09
F
S
30cd
1/2w
F
S
30cd
1/2w
F
S
30cd
1/2w
F
S
15cd
1w
F
S
15cd
1w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1w
F
S
15cd
1w
F
S
15cd
1w
F
S
15cd
1w
F
S
15cd
1w
F
S
30cd
1w
F
S
15cd
1/2w
F
S
75cd
1/2w
F
S
95cd
1/2w
F
S
95cd
1/2w
F
S
15cd
1/2w
F
S
30cd
1w
F
S
30cd
1/2w
F
S
95cd
2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
95cd
2w
F
S
75cd
1/2w
F
S
75cd
1/2w
F
S
30cd
1/2w
F
S
15cd
1w
F
S
30cd
1/2w
F
S cd
1/2w
F
S
15cd
1w
F
S
15cd
1w
F
S
75cd
1/2w
F
S
75cd
1/2w
F
S
30cd
1/2w
F
S
15cd
1w
F
S
30cd
1w
F
S
30cd
1/2w
F
S
15cd
1w
F
S
75cd
1/2w
F
S
15cd
1w
F
S
30cd
1w
F
S
75cd
1/2w
F
S
30cd
1w
F
S
30cd
1w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1w
F
S
15cd
1/2w
F
S
15cd
1w
F
S
15cd
1/2w
F
S
75cd
1/2w
F
S
15cd
1w
F
S
95cd
2w
F
S
95cd
2w
F
S
75cd
1/2w
F
S
95cd
1/2w
F
M15
F
S
75cd
1/2w
F
15cd
F
15cd
F
15cd
F
15cd
F
15cd
H
D06
S
D04
S
D05
S
D03
F A A P
S
D01
S
D07
S
DSD
D12
FR
M13
RTS
S
DSD
D13
FR
M14
RTS
FS
TS
FD
M18
M17
S
DSD
D02
FR M04
RTS
S
DSD
D08
FR
M07
RTS
S
DSD
D09
FR
M08
RTS
S
D S D
D10
FR
M10
RTS
F
F A C P
4'0' 12'
SCALE:
FIRE ALARM SYSTEM PLAN
FA-1.0 1/8"=1'-0"
F A A P
J
J
J
J
J
J
J
J
J
JJ
J
J
J
J
J
J
J
J
J
J
F A A P
S
D11
X
(1 1/4")V8,M8,S2,A1,D1
X
X
(1")V2,M2,S1,A1,N1,Z1,D1
X
(1")V2,M2,S1,A1,N1,Z1,D1
X
X
V2,M2,S1
X
V1,M1
X
V2,M2,S1
X
V1,M1,S1,A1,N1,Z1,D1
X
V1,M1,S1
X
V1,M1,S1 X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,D1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1,A1,N1,Z1
X
V2,M2,S1
X
V2,M2,S1,D1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1
X
V1,M1,S1
X
V1,M1,S1,D1
X
V3,M3,S1
X
V3,M3,S1
X
V3,M3,S1,D1
X
(1 1/4")V4,M4,S1,A1,N1,Z1,D1
X
V2,M2,S1
X
V2,M2,S1
X
(1")V4,M4,S2
X
V1,M1
X
V1,M1
X
V1,M1
X
V2,M2
X
(1 1/4")V6,M6,S1
X
V2,M2,S1
X
V1,M1,S1
X
V1,M1,S1,A1,N1,Z1,D1
X X
(1")V1,M1,S1,A1,N1,Z1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1
X
V1,M1,S1
X
V1,M1,S1
X
V3,M3,S1
X
(1")V4,M4,S2
X
V1,M1,S1
X
V1,M1,S1
X
V2,M2,S1
X
V2,M2,S1
X
V1,M1,S1
X
V2,M2,S1
X
V1,M1,S1,D1
X
V4,M4
X
(1")V4,M4
X
(1 1/4")V4,M4,S1,A1,N1,Z1,D1
X
(1")V4,M4,S1
X
(1 1/4")V6,M6,S2,A1
X
(1")V5,M5,S1
X
V2,M2,S1
X
V1,M1,S1,A1,N1,Z1
X
V1,M1,S1,A1,N1,Z1
X
(1")V2,M2,A1,N1,Z1 X
V3,M3
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1
X
V2,M2,S1
X
V1,M1,S1
X
V2,M2,S1
X
V1,M1,S1
X
V1,M1,S1,A1,N1,Z1
V2,M2,S1
X
V2,M2,S1
X
V1,M1,S1
X
V1,M1,S1
X
V1,M1
X
(1 1/4")V6,M6,S2
X
X
X
(1 1/4")V4,M4,S1,A1,N1,Z1,D1
X
V2,M2,S1,D1
X
(1 1/4")V4,M4,S1,A1,N1,Z1
X
(1 1/4")V4,M4,S1,A1,N1,Z1
X
V1,M1,S1
ST.2.4.1.MN
ST.4.4.1.FA
ST.2.4.2.MN
ST.4.4.2.FA
ST.2.4.3.MN
ST.4.4.3.FA
ST.2.4.4.MN
ST.4.4.4.FA
ST.2.4.5.MN
ST.4.4.5.FA
ST.2.4.6.MN
ST.4.4.6.FA
ST.2.4.7.MN
ST.4.4.7.FA
ST.2.4.8.MN
ST.4.4.8.FA
ST.1.1.2.MN
ST.3.1.2.FA
ST.1.1.3.MN
ST.3.1.3.FA
ST.1.1.6.MN
ST.3.1.6.FA
ST.1.1.7.MN
ST.3.1.7.FA
ST.1.1.8.MN
ST.3.1.8.FA
ST.1.1.10.MN
ST.3.1.10.FA
ST.1.1.9.MN
ST.3.1.9.FA
ST.1.1.11.MN
ST.3.1.11.FA
ST.1.2.1.MN
ST.3.2.1.FA
ST.1.2.2.MN
ST.3.2.2.FA
ST.1.2.3.MN
ST.3.2.3.FA
ST.1.2.4.MN
ST.3.2.4.FA
ST.1.2.5.MN
ST.3.2.5.FA
ST.1.2.6.MN
ST.3.2.6.FA
ST.1.2.7.MN
ST.3.2.7.FA
ST.1.2.8.MN
ST.3.2.8.FA
ST.1.2.9.MN
ST.3.2.9.FA
ST.1.3.1.MN
ST.3.3.1.FA
ST.1.3.2.MN
ST.3.3.2.FA
ST.1.3.3.MN
ST.3.3.3.FA
ST.1.3.4.MN
ST.3.3.4.FA
ST.1.3.5.MN
ST.3.3.5.FA
ST.1.3.6.MN
ST.3.3.6.FA
ST.1.3.7.MN
ST.3.3.7.FA
ST.1.3.8.MN
ST.3.3.8.FA
ST.1.3.9.MN
ST.3.3.9.FA
ST.1.3.10.MN
ST.3.3.10.FA
ST.1.3.11.MN
ST.3.3.11.FA
ST.1.4.1.MN
ST.3.4.1.FA
ST.1.4.2.MN
ST.3.4.2.FA
ST.1.4.3.MN
ST.3.4.3.FA
ST.1.4.4.MN
ST.3.4.4.FA
ST.1.4.5.MN
ST.3.4.5.FA
ST.1.4.6.MN
ST.3.4.6.FA
ST.1.4.7.MN
ST.3.4.7.FA
ST.1.4.8.MN
ST.3.4.8.FA
ST.1.4.9.MN
ST.3.4.9.FA
ST.2.1.4.MN
ST.4.1.4.FA
ST.2.1.5.MN
ST.4.1.5.FA
ST.2.1.6.MN
ST.4.1.6.FA
ST.2.1.7.MN
ST.4.1.7.FA
ST.2.3.1.MN
ST.4.3.1.FA
S.1.1
S.1.2
S.1.3
S.1.4
S.1.5
S.1.6
S.1.7
S.1.8
S.1.9
S.1.11
X
V1,M1,S1,A1,N1,Z1,D1
X
S1
S.1.14
S.1.15
S.1.16
S.1.17
S.1.18
S.1.19
S.1.23
S.1.24
S.1.25
S.1.26
S.1.27
S.1.28
S.1.29
J
X
S1
X
S1
JJ
X
(1 1/4")V8,M8,S2,A1,D1
J
X
(1 1/4")V8,M8,S2,A1,D1
J
J
S.3.1
J
X
S1
S.3.2
S.3.3
S.3.4
S.3.5
S.3.6
S.3.7
S.3.8
S.3.9
S.3.10
S.3.11
S.3.12
S.3.13
S.3.14
S.3.23
X
S1,D1
J
J
X
D1
S.3.32
S.3.33
S.3.34
S.3.35
S.3.36
S.3.37
S.3.38
S.3.39
S.3.40
J
X
(1")V4,M4,S1
X
S1,A1,N1,Z1,D1
X
(1 1/4")V4,M4,S1,A1,N1,Z1,D1
J
J
J
J
J
J
J
J
J
J
J
J
J
X
A1,N1,Z1,D1
J
X
A1,N1,Z1,D1
X
A1,N1,Z1,D1
X
V1,M1,A1,N1,Z1,D1
J J J
X
(1")V1,M1,S1,A1,N1,Z1,D1
X
A1,N1,Z1,D1
J
X
A1,N1,Z1,D1
J
X
A1,N1,Z1,D1
X
A1,N1,Z1,D1
X
A1,N1,Z1,D1
J
X
V1,M1,S1
X
A1,N1,Z1,D1
J
J
J
J
J
J
X
(1 1/4")V6,M6,S2,A1,D1
X
V1,M1
X
V1,M1,S1
X
D1
X
D1
J
X
V1,M1,S1,A1,N1,Z1,D1
X
J
X
V1,M1,D1,S1
X
X
X
D1
J
X
D1
X
D1
J
X
V1,M1,S1,D1
J
X
D1
J
X
D1
X
D1
X
D1
X
D1
X
D1
J
X
(1")V4,M4,S1,D1
J
X
(1")V4,M4,S1
X
D1
X
D1
X
D1
J
X
D1
X
R1
X
R1
X
R1
X
R1
X
R1
X
R1
J
X
V1,M1,A1,N1,Z1
X
D1
X
D1
BELL PROVIDED, POWERED,
AND INSTALLED BY OTHERS
NACPS
NACPS
NACPS
NACPS
AMP
MNS-T
1-1/2" CONDUIT WITH WEATHERHEAD
TO 4' ABOVE ROOF LINE FOR FUTURE
ANTENNA. RUN LMR 400 CABLE IN
THE CONDUIT. IF RUN IS LONGER THAN
200', THEN RUN LMR 600 CABLE. LEAVE
6' MINIMUM COIL ON EACH END.
MASS NOTIFICATION TRANSCEIVER
MOUNTED IN 18"x16"x10" NEMA 4X
ENCLOSURE.
LOCATED NEXT TO FACP
FM
M20
FM
M21
FM
M22
FM
M23
(1 1/4")V8,M8, S2,A1,N1,Z1
(1")V2,M2,S1,A1,N1,Z1,D1
(1")V2,M2,S1, A1,N1,Z1,D1
(1 1/4")V6, M6,S2
(1")V4,M4, S1,A1
X
D1
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
30cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
F
S
15cd
1/2w
X
V1,M1,S1
X
J
X
ST.1.1.1.MN
ST.3.1.1.FA
S.1.10
ST.1.1.5.MN
ST.3.1.5.FA
S.1.13
ST.1.1.4.MN
ST.3.1.4.FA
S.1.12
ST.2.1.1.MN
ST.4.1.1.FA
S.1.22
ST.2.1.2.MN
ST.4.1.2.FA
S.1.21
ST.2.1.3.MN
ST.4.1.3.FA
S.1.20
X
V1,M1
J
X
V1,M1,S1
J
ST.2.1.8.MN
ST.4.1.8.FA
S.3.15
ST.2.1.9.MN
ST.4.1.9.FA
S.3.16
ST.2.2.1.MN
ST.4.2.1.FA
S.3.17
J
ST.2.2.2.MN
ST.4.2.2.FA
S.3.18
ST.2.2.3.MN
ST.4.2.3.FA
S.3.19
ST.2.2.4.MN
ST.4.2.4.FA
S.3.20
ST.2.2.5.MN
ST.4.2.5.FA
S.3.21
ST.2.2.6.MN
ST.4.2.6.FA
S.3.22
ST.2.3.2.MN
ST.4.3.2.FA
S.3.24
ST.2.3.3.MN
ST.4.3.3.FA
S.3.25
ST.2.3.4.MN
ST.4.3.4.FA
S.3.26
ST.2.3.5.MN
ST.4.3.5.FA
ST.2.3.6.MN
ST.4.3.6.FA
X
V1,M1,S1
J
J
ST.2.3.7.MN
ST.4.3.7.FA
S.3.27
ST.2.3.8.MN
ST.4.3.8.FA
S.3.28
ST.2.3.9.MN
ST.4.3.9.FA
S.3.29
ST.2.3.10.MN
ST.4.3.10.FA
S.3.30
ST.2.3.11.MN
ST.4.3.11.FA
S.3.31
X
D1
X
V1,M1,S1
(1")V2,M2,S1,A1,N1,Z1
X
V2,M2,S1
X
V1,M1,S1
X
V1,M1
X
V1,M1,S1,D1
X
V1,M1,S1,D1
FD
M25
M24
KITCHEN HOOD
MONITORS (VERIFY
LOCATION)
V1,M1,D1,S1
V1,M1,D1,S1
V1,M1,D1,S1
(1")V2,M2,A1, N1,Z1,D1
SHEET TITLE
SHEET NUMBER
Opus Design Build, L.L.C.
Opus AE Group, L.L.C.
1860 NW 118th Street, suite 250
Clive, IA 50325
515-446-4940
10350 Bren Road West
Minnetonka, MN 55343-0110
952-656-4444
P L O
T
D
A T
E
PROJECT
PROJECT NUMBER
CONSULTANT
REGISTRATION
DRAWN BY
CHECKED BY
PROJECT MANAGER
DATE
PROJECT ADDRESS
FIRE ALARM
SYSTEM PLAN
FA-1.0
IA ANG -
CONSOLIDATED
SUPPORT FUNCTIONS
IOWA AIR NATIONAL GUARD
SIOUX CITY, IOWA
31290100
T. SACKETT
S. SHIFFLETT
05/04/2018
ISSUE RECORD
10/27/2017 FOUNDATION PERMIT
11/20/2017 A-2 SUBMITTAL
01/19/2018 DESIGN DEVELOPMENT
SUBMITTAL
02/21/2018 B-2 SUBMITTAL
05/04/2018 CONSTRUCTION SET
06/25/2018 GENERAL REVISION #1
4200 West 76th Street Minneapolis, Mn.
55435 Phone: 952-835-4600
Web Site: www.lvcinc.com
Iowa Fire Alarm License #: AS-0094
FIRE PROTECTION SYSTEMS INTEGRATION
A
M
NICET - NATIONAL INSTITUTE FOR
CERTIFICATION IN ENGINEERING
TECHNOLOGIES
MARK J. SNODGRASS
NICET LEVEL IV CERTIFIED IN FIRE
ALARM SYSTEMS
NICET CERTIFICATION #102343
EXPIRES: FEBRUARY 1, 2019
SIGNATURE:______________________
DATE: ___________________________
06-25-2018
| 185ARW-INWS-DRAWINGS |
| 185ARW-INWS-B234FL1-03 |
| 185ARW-INWS-B235FL1-03 |
| 185ARW-INWS-B240FL1-03 |
| 185ARW-INWS-B241FL1-SH1-03 |
| 185ARW-INWS-B241FL1-SH2-03 |
| 185ARW-INWS-B241FL1-SH3-03 |
| 185ARW-INWS-B241FL2-03 |
| 185ARW-INWS-B251FL1-03 |
| 185ARW-INWS-B252FL1-03 |
| 185ARW-INWS-B253FL1-03 |
| 185ARW-INWS-B254FL1-03 |
| 185ARW-INWS-B261FL1-03 |
| 185ARW-INWS-B261FL2-03 |
| 185ARW-INWS-B265FL1-01 |
| 185ARW-INWS-B269FL1-03 |
| 185ARW-INWS-B278FL1-03 |
| 185ARW-INWS-B280FL1-03 |
| 185ARW-INWS-B280MEZZ-03 |
| 185ARW-INWS-B283FL1-03 |
| 185ARW-INWS-B284FL1-03 |
| 185ARW-INWS-B286FL2-03 |
| 185ARW-INWS-B286FL1-03 |
| 185ARW-INWS-B311FL1-03 |
| 185ARW-INWS-SITEPLAN-SH1-03 |
| 185ARW-INWS-SITEPLAN-SH2-03 |
185ARW-INWS-DRAWINGS-265
File details come from the government source that posted it. Updated .