This document is an attachment containing drawings for a solicitation to Construct a Research Information Center (RIC) at Gunter Annex AFB in Alabama. The solicitation, numbered FA330024R0037, is being issued by the Department of the Air Force Air Education and Training Command. A site visit is scheduled for August 8, 2024, and offerors must submit a list of attendees by August 7th. Offerors are encouraged to visit the site to understand the work and conditions. Questions on the RFP can be submitted until August 9th. The solicitation does not provide details on the required products or services, pricing terms, set asides, incumbents, or award dates.
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. THE CONTRACT DOCUMENTS HAVE BEEN PREPARED TO BE
COMPLEMENTARY. WHAT IS REQUIRED BY THE DRAWINGS SHALL BE
REQUIRED BY THE SPECIFICATIONS, AND CONVERSELY. IN THE CASE
OF DISCREPANCIES CONCERNING QUALITY AND/OR QUANTITY
WITHIN THE DOCUMENTS, THE CONTRACTOR SHALL INCLUDE BETTER
QUALITY AND/OR THE GREATER QUANTITY, UNLESS OTHERWISE
DISTINGUISHED IN WRITING BY THE ARCHITECT. WHERE
SPECIFICATIONS HAVE BEEN OMITTED FOR THE MANUFACTURER OF
THE ITEM(S), THE CONTRACTOR SHALL EMPLOY THE HIGHEST
STANDARDS ESTABLISHED BY THE MANUFACTURER OF THE ITEM(S)
AS THE GUIDELINES FOR PRODUCT HANDLING, INSTALLATION OR
ERECTION AND PROTECTION OF THE COMPONENT, ONCE IN PLACE.
2. ALL WORK SHALL CONFORM WITH THE LATEST ADOPTED EDITION OF
THE ALABAMA BUILDING CODE, ALABAMA PLUMBING CODE, ALABAMA
MECHANICAL CODE, THE NATIONAL ELECTRICAL CODE AND ALL
OTHER APPLICABLE LOCAL, STATE AND FEDERAL CODES AND
ORDINANCES AND ALL AUTHORITIES HAVING JURISDICTION.
3. THE CONTRACTOR SHALL FURNISH & INSTALL ALL MATERIAL SHOWN
ON DRAWINGS OR INDICATED IN THE SPECIFICATIONS TO COVER THE
SCOPE OF WORK INDICATED ON THE DRAWINGS UNLESS OTHERWISE
INDICATED AS "EXISTING" OR BY OTHERS.
4. THE TERM "CONTRACTOR" AS REFERENCED THROUGHOUT THE
CONSTRUCTION DOCUMENTS SHALL MEAN THE GENERAL
CONTRACTOR (G.C.). IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO INTEGRATE, DIVIDE AND/OR SUBDIVIDE ANY AND
ALL ASPECTS OF THE WORK BASED ON HIS OPERATION.
CORRESPONDINGLY, IT SHALL BE THE CONTRACTOR'S
RESPONSIBILITY TO ASSURE THAT ALL WORK REQUIRED OR IMPLIED
BY THESE CONSTRUCTION DOCUMENTS IS PROVIDED/FURNISHED
AND INSTALLED COMPLETE IN A FIRST-CLASS WORKMANLIKE
MANNER UNLESS STATED OTHERWISE IN THESE CONSTRUCTION
DOCUMENTS.
5. THE CONTRACTOR SHALL MAINTAIN ORDERLY HOUSEKEEPING
DURING THE PROCESS OF CONSTRUCTION. DAILY CLEAN UP SHALL
INCLUDE THE REMOVAL OF ALL DUST, MATERIAL WASTE AND DEBRIS.
6. THE CONTRACTOR SHALL, UPON PROJECT COMPLETION,
THOROUGHLY CLEAN ALL AREAS. FINAL CLEAN UP SHALL INCLUDE
THE DUSTING AND REMOVAL OF DIRT, PAINT DRIPPING/OVERRUNS,
OIL, GREASE AND OTHER BLEMISHES FROM ALL SURFACES
INCLUDING SIDEWALKS, FIXTURES, COLUMNS, WALLS & EQUIPMENT.
7. ALL HARDWARE SHALL BE CLEAN AND POLISHED WITH A FLANNEL
CLOTH.
8. THE CONTRACTOR SHALL REMOVE ALL CONSTRUCTION RUBBISH,
SCAFFOLDING, EQUIPMENT, TEMPORARY PROTECTION, TEMPORARY
FIELD STRUCTURES AND ANY OTHER COMPONENTS WHICH WERE
REQUIRED IN CONNECTION WITH THE CONSTRUCTION, BUT NOT A
PERMANENT PART THEREOF.
9. THE CONTRACTOR MAY NOT SUBSTITUTE ANY "EQUIVALENT"
PRODUCTS FOR SPECIFIED PRODUCTS, UNLESS THE TERM "OR
EQUIVALENT" OR "OR EQUAL" IS DESIGNATED, WITHOUT APPROVAL
OF C.E/C.E.I.. ALL SUBSTITUTIONS MUST BE SUBMITTED PRIOR TO BID
FOR APPROVAL. NO SUBSTITUTES SHALL BE ALLOWED UNLESS "OR
EQUAL" IS DESIGNATED.
10. ALL PRODUCTS AND MATERIALS SHALL BE INSTALLED IN STRICT
CONFORMANCE WITH MANUFACTURE'S RECOMMENDATIONS.
11. THE CONTRACTOR'S OWN FORCES, SUBCONTRACTOR AND OTHER
ENTITIES UNDER THE CONTRACT TO THE CONTRACTOR THAT ARE
PERFORMING PORTIONS OF THE WORK SHALL BE SKILLED IN THEIR
RESPECTIVE TRADES AND COMMENSURATE WITH THE STANDARDS
OF WORKMANSHIP CONSISTENT WITH, AND REASONABLY INFERABLE
FROM, THE CONTRACT DOCUMENTS.
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY
PRECAUTIONS AND PRACTICES FOR PROTECTION OF PERSONS AND
PROPERTY IN CONJUNCTION WITH THE EXECUTION OF WORK
CONSISTENT WITH INDUSTRY-ACCEPTED PRACTICES AND
PROCEDURES AND IN ACCORDANCE WITH REQUIREMENTS OF
GOVERNING AUTHORITIES, INCLUDING O.S.H.A.
13. THE CONTRACTOR SHALL PROVIDE ACCESS TO THE WORK TO
C.E/C.E.I., HIS AGENTS AND GOVERNING AUTHORITIES AT ALL
REASONABLE TIMES, AS MAY BE REQUESTED OR REQUIRED BY LAW
OR PROJECT CONDITIONS.
14. FIGURED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE
MEASUREMENTS, DETAIL DIMENSIONS SHALL TAKE PRECEDENCE
OVER PLAN DIMENSIONS AND DETAILS SHALL TAKE PRECEDENCE
OVER SMALLER SCALE DRAWINGS.
15. DISCREPANCIES OR AMBIGUITIES FOUND SHALL BE REPORTED TO
THE CIVIL ENGINEER INSPECTOR AT ONCE FOR CLARIFICATION.
16. DIMENSIONS ON DRAWINGS ARE FACE OF STUD OF CENTERLINE OF
COLUMN UNLESS OTHERWISE NOTED OR UNLESS DIMENSIONED TO
EXISTING FINISHED SURFACE.
17. WHEN REQUIRED BY THE FIRE OFFICIAL HAVING JURISDICTION, THE
CONTRACTOR SHALL SUBMIT A PLAN DESCRIBING HOW THE ABOVE
WILL BE ACCOMPLISHED.
18. CONRACTOR SHALL FURNISH AND INSTALL ALL BUILDING MATERIALS
AND COMPONENTS THAT ARE MANUFACTURED AND ASSEMBLED IN
THE UNITED STATES. NO EXCEPTIONS. IF CONFLICT OCCURS IN
CONTRACT DOCUMENT LANGUAGE THIS STATEMENT GOVERNS IN
ALL CASES.
19. IF INTERRUPTION OF ANY BUILDING UTILITY SERVICES SUCH AS BUT
NOT LIMITED TO THE FOLLOWING, CHILLED WATER, ELECTRICAL
POWER, DOMESTIC WATER, FIRE PROTECTION WATER SUPPLY, OR
COMMUNICATIONS ETC. ARE REQUIRED, THE SUBCONTRACTOR
SHALL PERFORM THE WORK AFTER 5:00 PM AND BEFORE 7:00AM ON
WEEKDAYS OR NORMAL WORK WEEK HOURS DURING THE WEEKEND.
THE SUBCONTRACTOR SHALL COORDINATE THE INTERRUPTION OF
THE UTILITIES 45 DAYS IN ADVANCE WITH THE CIVIL ENGINEER
INSPECTOR AND USER. THE EXACT DAY AND TIME MUST BE
APPROVED BY THE USER. THE SUBCONTRACTOR SHALL INCLUDE
ANY ADDITIONAL COST OF PERFORMING THE WORK IN THEIR
ORIGINAL BID.
1. IT IS THE GENERAL CONTRACTORS RESPONSIBILITY TO
COORDINATE PHASING OF ALL WORK WITH THE CIVIL
ENGINEERING INSPECTOR, USER AND APPROVAL FROM
CONTRACTING OFFICER. CONTRACTOR SHALL SUBMIT A
WRITTEN PHASING AND WORK SCHEDULE FOR REVIEW
AND APPROVAL BY MAXWELL CIVIL ENGINEERING
INSPECTOR AND USER.
2. THE GENERAL CONTRACTOR SHALL COORDINATE ANY
WORK TO BE DONE AFTER NORMAL WORKING HOURS
WITH THE CIVIL ENGINEERING INSPECTOR AND USER AND
APPROVAL BY CONTRACTING OFFICER. NORMAL WORKING
HOURS ARE ESTABLISHED AS 0700-1700 MONDAY-FRIDAY.
PHASING NOTES
GENERAL NOTES
Number:
Reference
Sheet
Sy m bo l
D es cr ip tio n
Sc al e:
D at e:
C he ck ed
B y:
D ra w n
By
Ar ch ite ct ur al
J ob
R ev ie w ed B y:
D ra w in g Sh ee t F ile
D ra w in g Fo ld er
D at e Ap pr ov ed
1:
R ev is io ns
S TA T E OF A LABAMA
REG I S T ERED ARCH I T EC
T
J.MICHAEL
RUTLAND
TIMOTHY R.
HOLMES
T1.2
ST
N
/A
G
EN
ER
AL
N O
TE
S
AutoCAD SHX Text
MAXWELL AIR FORCE BASE
AutoCAD SHX Text
MAXWELL AFB, ALABAMA 36112
AutoCAD SHX Text
CONSTRUCT RESEARCH INFORMATION CENTER MAXWELL AFB - GUNTER ANNEX
AutoCAD SHX Text
JUBJ 22-1016
AutoCAD SHX Text
27 JULY 2023
AutoCAD SHX Text
42 CES/CEN
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text
AutoCAD SHX Text B
AutoCAD SHX Text A
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text C
AutoCAD SHX Text G
AutoCAD SHX Text F
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 22-1231
AutoCAD SHX Text
JC
AutoCAD SHX Text
JC
G
G
G G
G
G
G
G G
G
GG
G G
G
G
G
G
G
G
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
OP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
U P
W
W
W
W
W
W
W
W
W
W W
W W
W
WW
W
W
W
W W
W
W
W
W
W
W
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UC
UT
UT
UT
UT
U
T
UT
UT
UT
UT
UT
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
UP
UP
UP
UPUP
UP
UPUP
UP
UP
UP
UP
UP
U P
UP
UP
UP
UP
UP
UP
UP
UP
U P
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
UP
W
W
W
W
W
W
W
W
W
G
G
G
G
G
SD
MONTGOMERY
2 Froggy BottomPond
CSX TRANSPORTATION INC
NAV
Mitylene
Halcyon
Montgomery East
Cloverdale
West End
MONTGOMERY
New Town
Dalraida
Oak Park
Bottom
T
ME
MH
C T
C
T
MH
SS
MH
MH
C
H Y D
P G
M
CO
H Y D
SS
SS
SS
MH
MH
MH
MH
MH
T
ME
" C
LA
Y
T T
T
ME
" C
LA
Y
215.43
214.68
213.19
213.54
212.41
211.79
211.13
211.99 211.42
211.24
209.53 211.29 209.39
208.99 211.08
212.17
208.85
208.87 211.61
212.81 209.92
210.15212.88
212.26 210.29
212.58
213.48
212.00 211.98
210.19 213.07213.07
213.04
211.69
212.38 209.45
211.94 212.73
212.43
213.18
212.86
212.97
213.34
213.58
213.87
213.70
213.40
214.04
214.26
213.52212.60 213.45
214.30
213.86
213.10
213.22
214.22
214.19
213.44 213.19
214.00
215.23 214.33213.58
213.70
214.47
213.88 213.53
214.36
214.12
213.64
215.31
214.95
214.76 213.90
213.76
214.35
213.77
213.57
214.50
214.12
213.54 215.44
217.56
217.87 216.34
213.40 213.72
214.44
214.05
213.29
213.48
214.05
214.09
213.74 215.94
217.55
216.25 215.24
214.00
213.85
213.24
212.73 213.41
213.02
211.98
214.82
215.62
217.08 217.91 218.35
218.70
217.88
217.06
216.62 215.68
217.06 217.62
219.35
219.65 218.64
218.06 218.73
219.77
219.90 218.12
217.07
215.78 216.77
216.42
217.24
217.35
217.46
217.67
217.81
218.04
218.17
218.41
218.65
218.82
218.82
218.83
219.08
219.65 220.03
220.51
220.66
220.58
220.46
220.43
220.35
220.20
220.09
219.99
219.85
219.82
216.33216.31
216.09
215.65
215.68
215.31
214.59 215.11
215.35
215.63
215.04
214.49
214.58
214.91 214.94
213.97214.18
214.25
213.38 213.16
213.02
212.63
212.73
215.22 215.15
214.68
215.97
215.19
215.86 215.67
215.79
215.64
217.28
216.79
216.26
216.01
215.33
216.23 215.96
216.06
216.40 216.62
216.73
217.05
217.34 217.59
216.90
216.40
218.24
218.48
218.18 217.94
217.66 217.48
217.33
216.54 216.64 217.26
217.15
216.61 216.43
216.39 215.87
216.00 215.82215.80
217.51
217.69
217.67
218.50
218.73
218.53
217.87218.06
218.49 218.51
217.75
217.23
216.95
217.20
217.53
217.45
217.33
217.87
219.02 217.58
217.95 218.65
218.06
219.72
218.83
218.53
218.52218.55
218.96
218.91
220.64 219.34219.02
219.10
219.28
219.66
220.01 220.15
220.37
223.47
224.45 224.18
225.27
225.86 225.78
224.51
224.39225.65
226.44 225.83
226.21 226.49
224.46
227.13
226.71
227.30 228.72
228.68
225.33 227.57
228.10 227.74
228.18 228.82
228.12 228.10
228.51
223.12
223.81
223.91
223.87 223.31
222.75
223.74
224.07
223.45 223.25
222.80 222.99
223.82
223.86
223.43
222.78
222.30 223.19
223.87
223.96
223.70 223.63
224.44
223.63
223.98
223.90
223.11221.40
223.31
223.86
223.79
223.61
224.22 223.53
223.84
223.58
222.72
222.95
222.70
223.76
223.60
223.34
223.49
223.76
223.48 223.22
222.74
223.09
222.97 223.20
222.95
223.70
223.66
218.87 218.97
219.89 219.93
219.69
220.47
221.09
222.19 221.76
221.24
222.06 222.80
222.95
221.33
221.71
221.36 223.56
223.63
223.53 225.63 225.70 224.92
225.77 225.16
224.33 223.51
223.13
222.24 222.82
221.05 219.68
219.76
219.89 219.82
221.03 220.76
219.96
224.63
225.11 222.53
225.34
218.32
218.32 218.57
218.38
218.44 218.67
218.44
218.16 218.47
218.43 218.59
218.71
218.46 218.34218.04
218.23
218.31 218.29
218.16
218.09
218.09 215.43215.44
215.47215.66 215.58
224.53
226.31
226.90
227.30
228.06
228.37
226.97
226.63
226.04
224.88
224.95
225.25
223.60
223.27 222.92
220.19
219.63 219.61
220.79
220.65220.09
220.33
220.32219.74
219.75220.28
219.98
219.07
219.16 219.02
218.21 218.35
217.24216.12
217.28
223.14
222.70
220.06
219.43218.96
218.30217.97
218.05
220.60 220.85220.85
221.09220.62
222.00222.47 221.49
221.80
219.83
219.53
217.64
217.80
216.39
216.14
220.08
219.74
219.45
219.34
220.21
219.38
219.05
219.52
219.72
220.03
219.87
219.66
219.24
218.46
218.54
219.10
219.43
219.74
223.68 223.92
223.89 223.94
224.00
224.13 224.00
224.03
223.69
224.69
225.71
226.59
227.31227.26
227.48 227.61
227.68
224.17224.07
224.41 224.27
221.31 221.21220.66221.20
220.18
219.19
219.22 219.38
220.51
221.36 221.37
219.02219.07219.13219.40
219.13
219.12
219.21
219.20 218.93
218.69
218.04
218.11217.84
218.72
218.60
217.87
217.66
217.61 217.33
216.64
217.21
217.71
217.84
218.84
219.84
219.96 219.92
218.17
218.44 218.49
218.23
220.03
220.07
219.74
222.07 220.31
220.33
219.71
219.70
219.86
219.98 219.97
218.93
217.90 217.77
217.53
216.44216.21216.05
216.35216.14 216.14
216.36
216.59
216.91
217.44
218.11
218.26
217.30
217.10
217.60
217.42
217.66 217.91 217.84
217.63217.74
217.50
217.52 217.53
218.40 218.27
217.97 218.05
217.61
217.26 217.45
217.27 217.15
216.80
216.28
215.83
215.37 215.18
214.76 214.78
216.10
216.25
216.52216.93
215.25
215.52
215.31
216.88
216.40
216.15
215.62 215.84
215.87
215.84
214.14
215.20
215.22 214.81
215.18
215.31 215.79 215.68
215.83
215.81
215.37
215.14 215.02215.08
215.22215.19
215.11
214.94
215.08
215.31 215.06
214.65
214.26
213.98
213.61
214.73 214.62
214.27
213.93
213.73
213.55
212.77
212.67
212.91 211.16
212.94
213.11 213.10
214.14
214.68 214.75
215.14
213.70 213.98
215.55
217.33217.44
217.93
217.81
215.94
214.01 214.04
212.58 212.57
211.66
208.91
209.98
210.50
211.95
210.57
209.78
209.94
214.04
214.37
212.37
212.15
211.91212.29
210.70
210.61
210.78
210.51
209.83
209.46
209.79
209.26
208.54
209.12
208.26 208.64
208.69208.32
209.13 209.19209.72
209.46 208.97
209.39
209.91
208.92
209.61
209.53
209.09 209.84
211.82
209.25
227.72
H Y D
21321
226226
SANITARY SEWER MANHOLE - 210.62
DROP INV. IN - 208.08
INV. IN - 203.99
INV. OUT - 203.79
STORM MANHOLE - 212.70
10" CLAY F.L. - 208.62
15" RCP F.L. - 206.20
18" RCP F.L. - 206.12
GRATE INLET - 211.72
15" PVC F.L. - 209.50
GRATE INLET - 213.28
15" RCP F.L. - 208.66
15" RCP F.L. - 208.61
GRATE INLET - 212.07
10" RCP F.L. - 210.21
10" RCP F.L. - 209.96
GRATE INLET - 212.62
10" RCP F.L. - 209.93
12" RCP F.L. - 209.63
ELECTRIC MANHOLE
STORM MANHOLE - 213.47
15" RCP F.L. - 208.17
15" RCP F.L. - 208.14
STORM MANHOLE - 210.44
THROAT - 209.72
18" PVC F.L. - 207.13
21" PVC F.L. - 207.08
STORM MANHOLE - 208.85
THROAT - 208.00
15" RCP F.L. - 206.32
12" RCP F.L. - 206.24
21" PVC F.L. - 205.85
24" RCP F.L. - 205.74
SANITARY SEWER MANHOLE - 211.35
INV. IN F.L. - 205.14
INV. OUT F.L. - 205.01
STORM MANHOLE - 211.91
10" CLAY F.L. - 208.98
15" RCP F.L. - 207.43
15" RCP F.L. - 207.21
STORM MANHOLE - 219.23
6" PVC F.L. -212.76
15" RCP F.L. - 212.60
15" RCP F.L. - 212.58
STORM MANHOLE - 219.70
6" PVC F.L. -213.73
15" RCP F.L. - 213.69
15" RCP F.L. - 213.51
GRATE INLET - 214.53
12" PVC F.L. - 211.39
12" PVC F.L. - 211.35
GRATE INLET - 215.75
12" PVC F.L. - 213.11
WATER T END
GRATE INLET - 219.50
15" PVC F.L. - 214.99
GRATE INLET - 219.10
12" PVC F.L. - 215.80
15" PVC F.L. - 215.75
3" INVERT PIPE
BIG FINK TEST
STATION
GRATE INLET - 222.43
12" PVC F.L. - 218.52
12" PVC F.L. - 216.18
GRATE INLET - 222.56
6" CLAY F.L. - 219.58
12" RCP F.L. - 218.72
12" RCP F.L. - 218.65
GRATE INLET - 222.13
ONLY 1 VISIBLE PIPE!
6" CLAY F.L. - 219.98
SANITARY SEWER MANHOLE - 223.06
DEAD? - DEBRIS IN F.L.
INV. IN F.L. - 217.25
INV. OUT F.L. - 217.22
SANITARY SEWER MANHOLE
LID SHUT
STORM MANHOLE - 224.80
THROAT - 223.99
21" PVC F.L. - 221.54
21" PVC F.L. - 221.27
STORM MANHOLE - 220.93
THROAT - 220.02
21" PVC F.L. - 216.37
10" PVC F.L. - 216.30
21" PVC F.L. - 216.04
15" RCP F.L. - 215.94
SET TBM 4-6-23
X MARK ON
N BOLT OF FH
ELEV. - 221.78
GRATE INLET - 219.16
10" PVC F.L. - 217.19
STORM MANHOLE
CANNOT OPEN
ELECTRIC MANHOLE
ELECTRIC MANHOLE
POWER
BOX
POWER
BOX
POWER
BOX
POWER
METER
WATER
VAULT
STEEL LID
GAS/WATER VAULT?
SD
SD
"P
VC
T
O
0" R
CP
SD
SD
SD
SD10
" R
CP
SD
SD
" R
CP
T
O
ST
OR
M
DR
AI
N
IN
TE
RS
EC
TI
ON
SDSD
15" RCP TO STORM
DRAIN INTERSECTION
SD
SD
15" RCP TO
UNKNOWN
6" P
VC
SD
SD
15" RCP TO UNKNOWN
SD
SD
SD
SD
SD
" R
CP
SD
SD
SD
SD
15" RCP
SD
SD18" RCP TO UNKNOWN
15" RCP
21" PVC
SD
SD
SD
15" RCP
15" RCP
SD
24" RCP
SD
12" R
CP TO UNKNOWN
SD
SD
SD
SD
SD
SD
" P
VC
T
O
JU
NC
TI
ON
B
OX
21" PVC TO JUNCTION BOX?
21" PVC
SD21" PVC TO UNKNOWN
SEWER MANHOLE
CANNOT OPEN!
6" CLAY
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
" P
VC
MH
SD
SD 12" PVC
SD
SD
SD12" PVC TO UNKNOWN
NO VISIBLE PIPE
SS
DRO
P INV DIRECTIO
N
WATER VAULT
15" R C
P
SD
" P
VC
T
O
UN
KN
OW
N
SD
" P
VC D
IR
ECTI
ON
MONTGOMERY
NewTown
Chisholm
Boylston MadisonPark
Dalraida
HD
IP
MAXWELL AIR FORCE BASE
GUNTER ANNEX( )
CSX TRANSPORTATIONINC
M O
N
TG
O M
ER
Y, A L.
H
ER
R
O N
S
TR
EE
T
T
EL
.(3
)2
-1
LA
RR
Y E.
S
PE
AK
S
LA
N
D S
U R
VE
YO
R S
C O
N
SU
LT
IN
G E
N G
IN
EE
R S
AS
SO
CI
AT
ES
, I
NC
SHEET
OF
D R
AW
IN
G T
IT
LE
TO
PO
G R
AP
H
IC
SU
R
VE
Y
Pr oj ec t N o.
D w g N am e:
Sc al e:
D ra w n By
R ev ie w ed
B y:
D at e Is su ed
To po
.d w g 1"
=3 0'
SA
S
SE
S
4/
/2
R
EV
IS
IO
N S
N o.
D
ES
C R
IP
TI
O N
D
AT
E
NORTHMONTGOMERY COUNTY, AL
LOCATION MAP
TOTAL 1
N
EW
S
00 30' 60'
SCALE: 1"=30'
LEGEND:
NOTES: 1.
2. UTILITY LOCATES AND PIPE LOCATES DONE BY
ALABAMA ONE AND THE UTILITY LOCATORS FOR
MAXWELL/GUNTER AFB.
TOPOGRAPHIC SURVEY
FOR
RESEARCH INFORMATION CENTER,
MAXWELL-GUNTER ANNEX,
MONTGOMERY COUNTY, ALABAMA
STATE PLANE
GRID NORTH
PROJECT
LOCATION
TO
PO
G R
A
PH
IC
S
U R
VE
Y
FO
R
R
ES
EA
R
C H
IN
FO
R M
AT
IO
N C
EN
TE
R
M
AX
W
EL
L- G
U N
TE
R
A N
N
EX
M
O N
TG
O
M
ER
Y C
O U
N
TY
, A
LA
BA
M
A
ASPHALT
CONCRETE
EXISTING CONTOUR
SPOT ELEVATION
505.12
VI
MH
T
P
FOUND CONCRETE MARKER
G
W
SS
UNDERGROUND ELECTRICUE
POWER BOX
ICV
WATER METER
WATER LINE
GAS LINE
STORM DRAIN PIPE
STORM MANHOLE
SANITARY SEWER
SS SANITARY SEWER MANHOLE
TELEPHONE BOX
CABLE BOXC
SIGN
UT UNDERGROUND TELEPHONE
WATER VALVE
GAS METERG
CO CLEANOUT
H Y D
FIRE HYDRANT
GRATE INLET
LIGHT POLE
WATER FAUCET
SD
ME ELECTRIC MANHOLE
GAS VALVE
POST INDICATOR VALVE
BBQ GRILL
NOTE: ELEVATIONS ESTABLISHED BY GPS
AL. 60 ALDOT 6 DIVISION CORS STATION
NAVD 88, MONTGOMERY COUNTY.
lee.tharp Text Box C1
21" PVC TO UNKNOWN
6" CLAY
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
SCALE: 1"=10'
10 20
5 15
N
SITE DEMOLITION NOTES:
1. CONTRACTOR TO COORDINATE WITH OWNER PRIOR TO ANY DEMOLITION REGARDING ITEMS TO BE SALVAGED, RECYCLED, AND REUSED. CONTRACTOR SHALL REMOVE ITEMS TO BE SALVAGED WITH EXTREME CAUTION TO PREVENT DAMAGE.
CONTRACTOR SHALL TURN ALL SALVAGED ITEMS OVER TO OWNER. CONTRACTOR SHALL COORDINATE WITH OWNER AND THE UTILITY PROVIDER PRIOR TO THE DISCONNECTING OR REMOVAL OF ANY UTILITY SERVICE TO THE EXISTING BUILDINGS.
ALL UTILITIES TO BE REMOVED ARE TO BE CAPPED OR PLUGGED OR TERMINATED ACCORDING TO THE UTILITY OWNERS
REQUIREMENTS.
2. REFER TO, SITE GRADING AND UTILITY PLANS FOR PROPOSED UTILITY AND DRAINAGE INSTALLATION AND REMOVAL.
3. REFER TO LAYOUT PLANS FOR ADDITIONAL INFORMATION RELATING TO PAVING, CURB, SIDEWALKS, HARDSCAPES, ETC
REMOVE EXISTING CURBS AS NEEDED TO INSTALL PROPOSED IMPROVEMENTS.
4. CONTRACTOR SHALL COORDINATE WITH OWNER, ARCHITECT, LBYD AND THE UTILITY PROVIDER PRIOR TO THE
DISCONNECTING OF ANY UTILITY SERVICE TO THE EXISTING BUILDINGS.
5. CONTRACTOR SHALL BE RESPONSIBLE FOR THE REMOVAL, RELOCATION OR PROTECTION OF ALL ABOVE AND BELOW GROUND EXISTING IMPROVEMENTS THAT ARE IN CONFLICT WITH THE PROPOSED IMPROVEMENTS UNLESS NOTED.
6. ALL DEMOLITION AND CONSTRUCTION DEBRIS SHALL BE TRANSPORTED AND DISPOSED OF AT LEAST WEEKLY IN A LEGAL
AND APPROVED MANNER.
7. ALL EXISTING PAVING, CURBS, HARDSCAPE, ETC. SHALL BE SAW CUT AT THE LIMITS OF REMOVAL IN ORDER TO PROVIDE A CLEAN EDGE. EXISTING PAVING AT EDGE SHALL BE MILLED BACK A MINIMUM OF 1.5' TO ENSURE SMOOTH TRANSITION.
8. SEE ELECTRICAL PLAN FOR DETAILS ON LIGHT POLE REMOVAL
REMOVE EXISTING SIDEWALK
REMOVE EXISTING SIDEWALK
REMOVE AND REROUTE
COMMUNICATIONS BOX
(SHOWN FOR
REFERENCE ONLY, SEE
ELECTRICAL PLANS)
CONCRETE SIDEWALK TO
BE REMOVED
ITEM TO BE REMOVED
ITEM TO BE REMOVED
REMOVE LIGHT POLE
(SEE ELECTRICAL PLAN
FOR DETAILS)
B2/C2
EXISTING CONCRETE
SIDEWALK TO REMAIN
EXISTING STORM
MANHOLE TO REMAIN
EXISTING STORM INLET TO REMAIN
REMOVE EXISTING SIDEWALK
FOR NEW SANITARY LINE
EXISTING SANITARY SEWER
MANHOLE TO REMAIN SAWCUT AT LIMITS OF
REMOVAL (TYP.)
EXISTING LIGHT POLE AND
CIRCUIT TO REMAIN
EXISTING CONCRETE
SIDEWALK TO REMAIN
EXISTING ASPHALT AND
STRIPING TO REMAIN
EXISTING LIGHT POLE
AND CIRCUIT TO REMAIN
EXISTING SIDEWALK TO
BE SAWCUT AT LIMITS TO
BE REPLACED
EXISTING ASPHALT TO BE
SAWCUT AT LIMITS AND
REMOVED
EXISTING STORM DRAIN TO REMAINEXISTING WATER LINE TO REMAINSAW CUT AT LIMITS OF
REMOVAL
SAW CUT AT LIMITS OF
REMOVAL
EXISTING SIDEWALK TO
REMAIN
EXISTING SIDEWALK TO
REMAIN
EXISTING LIGHT POLE
AND CIRCUIT TO REMAIN
REMOVE LIGHT POLE
(SEE ELECTRICAL PLAN
FOR DETAILS)
7/27/20
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
SCALE: 1"=10'
10 20
5 15
N
GENERAL NOTES:
LBYD, INC. SHALL NOT HAVE AUTHORITY OVER THE SITE OR BUILDING CONTRACTOR'S WORK OR RESPONSIBILITIES. LBYD IS NOT
RESPONSIBLE FOR SITE SAFETY PROCEDURES OR METHODS OF CONSTRUCTION.
1. ALL EXISTING UTILITIES SHOWN ON THESE DRAWINGS ARE APPROXIMATE AND OTHER UTILITIES MAY EXIST. CONTRACTOR MUST COORDINATE LINE LOCATES WITH W.C.E. WITH MINIMUM 2 WEEKS NOTICE AS WELL AS FIELD VERIFIED BY ONSITE PERSONNEL PRIOR TO ORDERING MATERIALS OR BEGINNING CONSTRUCTION. ANY DISCREPANCIES SHALL BE REPORTED
TO LBYD IMMEDIATELY.
2. EXISTING UTILITIES TO REMAIN MAY BE LOCATED WITHIN PROPOSED DEMOLITION AREAS. CONTRACTOR SHALL USE EXTREME CAUTION WHILE WORKING IN THESE AREAS TO ENSURE NO UTILITY SERVICE INTERRUPTIONS TO FACILITIES THAT
REMAIN OR TO ADJACENT PROPERTIES.
3. ALL EXISTING IMPROVEMENTS WITHIN THE LIMITS OF CONSTRUCTION ARE TO BE REMOVED UNLESS SPECIFICALLY
NOTED,"TO REMAIN".
4. THE CONTRACTOR SHALL TAKE ALL NECESSARY MEASURES TO PROTECT ADJACENT PROPERTIES AND IS RESPONSIBLE FOR ANY DAMAGE TO EXISTING IMPROVEMENTS ON OR OFF SITE DUE TO THE CONSTRUCTION OF THIS PROJECT. ANY DAMAGE
WILL BE REPAIRED AT THE CONTRACTOR'S EXPENSE.
5. CONTRACTOR SHALL VERIFY SITE BOUNDARY AND EXISTING TOPOGRAPHY. NOTIFY LBYD OF ANY DISCREPANCIES PRIOR TO
SUBMITTING PRICES OR ORDERING MATERIALS
6. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROTECT ALL BENCHMARKS AND PROPERTY CORNERS. ANY REPLACEMENT
WILL BE AT THE CONTRACTOR'S EXPENSE.
7. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO OBTAIN ALL NECESSARY PERMITS REQUIRED TO CONSTRUCT THIS PROJECT AND PAY ALL PERMIT FEES. ALL PERMITS MUST BE IN-HAND PRIOR TO CONSTRUCTION.
8. BOUNDARY AND TOPOGRAPHIC INFORMATION PERFORMED BY LARRY E. SPEAKS & ASSOCIATES.
9. TOPOGRAPHIC INFORMATION WAS PERFORMED VIA GROUND RUN FORMAT.
SITE LAYOUT NOTES:
1. ALL HANDICAP RAMPS, SIGNS, SYMBOLS, AND PAINTED ISLANDS AND ACCESS ROUTES MUST CONFORM TO THE LATEST ADA
REQUIREMENTS.
2. THE MAXIMUM SLOPE IN HANDICAP PARKING AREAS SHALL NOT EXCEED 2.0% GRADE IN ANY DIRECTION. SLOPE IN THE DIRECTION OF TRAVEL IN ALL HANDICAP ACCESS ROUTES SHALL NOT EXCEED 5.0% GRADE AND 2.0% CROSS SLOPE.
3. ALL DIMENSIONS AND COORDINATES SHOWN ARE TO THE [OUTSIDE FACE OF BUILDING, OR COLUMN LINES] TO THE BACK OF CURB, OR TO THE EDGE OF SURFACING UNLESS OTHERWISE NOTED. REFER TO ARCHITECTURAL PLANS FOR SPECIFIC
BUILDING INFORMATION.
4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING A SITE CONSTRUCTION TRAFFIC CONTROL PLAN AND OBTAINING ANY REQUIRED APPROVALS FROM THE LOCAL JURISDICTIONAL AUTHORITY. THE SITE CONSTRUCTION TRAFFIC CONTROL PLAN SHALL TAKE INTO ACCOUNT THE ENTERING AND EXITING OF CONSTRUCTION TRAFFIC ONTO THE ROADWAY AND THE IMPACT TO THE FLOW OF TRAFFIC. THIS PLAN SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF THE MUTCD. THIS SITE CONSTRUCTION TRAFFIC CONTROL PLAN SHALL BE IN ADDITION TO ANY TRAFFIC CONTROL PLAN
PROVIDED IN THE PLAN SET FOR ROADWAY IMPROVEMENTS.
5. CONTRACTOR IS RESPONSIBLE FOR ADJUSTING ELEVATIONS OF ALL AT-GRADE STRUCTURES AND UTILITIES TO REMAIN
(VALVE BOXES, MANHOLES, INLETS, VAULTS, ETC) TO MATCH PROPOSED FINISHED GRADES.
CONCRETE SIDEWALK (SEE DETAIL)
CONCRETE SIDEWALK (SEE DETAIL)
NEW BUILDING
FFE = 224.00
B3/C3
STAIRS ON GRADE
(SEE DETAIL)TIE TO EXISTING
SIDEWALK WITH
SMOOTH TRANSITION
TIE TO EXISTING
SIDEWALK WITH
SMOOTH TRANSITION
CONCRETE SIDEWALK (SEE DETAIL)
5'
5'
5'
5.39'
.33
.62
5'
36.33'
5'
CONCRETE SIDEWALK
CONCRETE PAVING
STAIRS ON GRADE
(SEE DETAIL)
ACCESSIBLE PARKING
SYMBOL AND STRIPING
(SEE DETAIL) (TYP.)
IN-LINE ACCESSIBLE
RAMP (SEE DETAIL)
CONCRETE PAVING IN
ACCESSIBLE PARKING
(SEE DETAIL)
EXISTING ASPHALT
PAVING AND STRIPING
TO REMAIN
EXISTING ASPHALT
PAVING AND STRIPING
TO REMAIN
SIDEWALK FLUSH WITH PAVEMENT
NEW EDGE OF SIDEWALK
ACCESSIBLE PARKING
SIGN WITH "VAN" PLAQUE
(SEE DETAIL)
ACCESSIBLE PARKING
SIGN (SEE DETAIL)
18' 9'
(TY
P)
9'
(TY
P)
9'
(TY
P)
6'
5'
5'
6'
5'
5'
5'
TIE TO EXISTING
PAVEMENT WITH
SMOOTH TRANSITION
TIE TO EXISTING SIDEWALK
WITH SMOOTH TRANSITION
TIE TO EXISTING SIDEWALK WITH
SMOOTH TRANSITION
NEW HAND/GUARD RAILS
(SEE ARCHITECTURAL DETAIL)
7/27/20
5'
TIE TO EXISTING
SIDEWALK WITH
SMOOTH TRANSITION
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
0 22
ST
ST
ST
ST
ST
ST
ST
SCALE: 1"=10'
10 20
5 15
GRADING NOTES:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING COMPACTION TESTING.
2. ALL TOPSOIL SHALL BE STRIPPED WITHIN THE PROPOSED LIMITS OF GRADING AND SHALL BE STOCKPILED ON-SITE IN AN APPROVED LOCATION FOR LATER USE WITH ANY EXCESS TO BE DISPOSED OF OFF-SITE ONCE ALL LANDSCAPED AREAS
HAVE BEEN BROUGHT TO FINISH GRADE UNLESS OTHERWISE NOTED ON THE PLANS.
3. SUBGRADE SHALL BE PROOF ROLLED WITH A HEAVILY LOADED DUMP TRUCK AND APPROVED BY THE GEOTECHNICAL ENGINEER PRIOR TO PLACING FILL. ANY AREAS SHOWING SIGNS OF PUMPING, RUTTING, OR ANY UNSUITABLE (ORGANIC, SOFT, WET, LOOSE) MATERIAL FOUND IN PLACE SHALL BE UNDERCUT AND REPLACED, OR MOISTURE CONDITIONED AND
COMPACTED TO THE SPECIFIED DENSITY AND MOISTURE CONTENT LISTED BELOW.
4. ALL EXPOSED SUBGRADE SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 12", MOISTURE CONDITIONED, AND RECOMPACTED, AS NEEDED TO ACHIEVE THE SPECIFIED DENSITY AND MOISTURE CONTENT LISTED BELOW, UNLESS OTHERWISE
DETERMINED BY A GEOTECHNICAL ENGINEER.
5. CONTRACTOR SHALL BE RESPONSIBLE TO PROTECT PREPARED SUBGRADE AND RESTORE TO PROJECT SPECIFICATIONS IF
DAMAGED OR COMPROMISED DUE TO INCLEMENT WEATHER AND/OR CONSTRUCTION TRAFFIC.
6. FILL MATERIAL SHALL HAVE THE FOLLOWING PROPERTIES: VIRTUALLY FREE OF ORGANICS, NO ROCK FRAGMENTS GREATER THAN [4"] WITHIN [4'] OF FINISH GRADE, LIQUID LIMIT NOT EXCEEDING 50, PLASTICITY INDEX NOT EXCEEDING 30, AND A MAXIMUM DRY DENSITY OF NO LESS THAN 100PCF AS DETERMINED BY ASTM D-698, MODIFIED PROCTOR.
7. PLACE FILL MATERIAL IN 8" MAXIMUM LOOSE LIFTS AND COMPACT TO REQUIREMENTS LISTED BELOW.
8. COMPACTION TESTS SHALL BE TAKEN AT THE RECOMMENDATION OF THE ON-SITE GEOTECHNICAL ENGINEER, BUT AT A
MINIMUM EVERY 2,500 SQUARE FEET OF AREA PER 8" LIFT.
9. FILL MATERIAL TO BE WITHIN ±2.0% OF OPTIMUM MOISTURE CONTENT AT THE TIME OF COMPACTION, UNLESS OTHERWISE
DETERMINED BY A GEOTECHNICAL ENGINEER.
10. MINIMUM COMPACTION REQUIREMENTS ARE EXPRESSED BELOW AS A PERCENTAGE OF THE MATERIAL'S MAXIMUM DRY
DENSITY AS DETERMINED BY MODIFIED PROCTOR ASTM D-1557.
*STRUCTURAL AREAS INCLUDE ZONES OF INFLUENCE AROUND THE BUILDING, PAVEMENT AREAS, FILL SLOPES, ETC.
11. COMPACTION WITHIN LIMITED SPACES (I.E. MANHOLES, INLETS, UTILITY TRENCHES) SHOULD BE BACKFILLED AND COMPACTED SYSTEMATICALLY, AT THE DIRECTION OF THE ON-SITE GEOTECHNICAL ENGINEER. STONE BACKFILL SHALL BE INSTALLED IN 12" MAXIMUM LOOSE LIFTS AND COMPACTED WITH 6-8 PASSES OF A VIBRATORY COMPACTOR.
12. CLEARING LIMITS SHALL BE 5' OUTSIDE OF ALL PROPOSED GRADED AREAS OR NOT BEYOND THE PROPERTY LINES
WHICHEVER IS LESS.
13. NO GRADING OFF-SITE OR IN ANY ROAD RIGHT-OF-WAY WITHOUT PROPER APPROVALS AND PRIOR NOTIFICATION.
14. COORDINATE THE SEQUENCING OF ALL GRADING OPERATIONS WITH THE EROSION CONTROL PLAN.
15. THE MAXIMUM SLOPE IN HANDICAP PARKING AREAS SHALL NOT EXCEED 2.0% GRADE IN ANY DIRECTION. SLOPE IN THE DIRECTION OF TRAVEL IN ALL HANDICAP ACCESS ROUTES SHALL NOT EXCEED 5.0% GRADE AND 2.0% CROSS SLOPE.
16. ALL GRADING ADJACENT TO EXISTING OR PROPOSED BUILDINGS SHALL BE SLOPED AWAY FROM THE STRUCTURES AT A MINIMUM OF 1.0% GRADE. THE CONTRACTOR SHALL ENSURE POSITIVE DRAINAGE AWAY FROM THE STRUCTURES. NOTIFY
LBYD OF ANY DISCREPANCIES.
17. PROPOSED GRADES INDICATED ON THIS PLAN ARE TO FINISH GRADE. THE CONTRACTOR SHALL MAKE SUBGRADE
ADJUSTMENTS FOR TOPSOIL, PAVING, BUILDING PAD, ETC.
18. ALL PROPOSED STORM INLETS (GRATES, CURB, YARD, AREA DRAINS) SHALL BE LOCATED AT THE LOWPOINTS. GRADING
SHALL BE TO DIRECT RUNOFF TO THESE INLETS. NOTIFY LBYD OF ANY DISCREPANCIES.
19. STORM DRAINAGE SYSTEMS SHALL BE CONSTRUCTED FROM DOWNSTREAM TO UPSTREAM. VERIFY ALL PIPE SLOPES, INVERTS, AND POINTS OF CONNECTION PRIOR TO CONSTRUCTION. NOTIFY LBYD OF ANY DISCREPANCIES.
20. FILL SLOPES SHOULD BE BENCHED INTO THE EXISTING SLOPES AND SHOULD BE COORDINATED WITH THE ONSITE GEOTECHNICAL ENGINEER FOR BENCH DETAILS (HEIGHT AND DEPTH OF BENCH INTO THE SLOPE.)
21. WHERE ROCK IS ENCOUNTERED WITHIN 18" OF THE PAVING SUBGRADE AND 36" OF THE BUILDING SUBGRADE,, THE "CUT LINE" SHALL BE PER THE SPECIFICATIONS. SEE THE SPECIFICATIONS FOR "CUT LINE" DIMENSIONS BELOW BUILDING PADS AND PARKING AREAS. SUITABLE MATERIAL SHALL BE REPLACED TO THE PROPOSED SUBGRADE ELEVATION.
22. GRADING ADJACENT TO THE BUILDING SHALL BE COORDINATED WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR FOUNDATION WALLS, STEM WALLS, DRAINS, AND OTHER CONDITIONS. THE CONTRACTOR SHALL NOTIFY LBYD INC. OF ANY
DISCREPANCIES.
AREA STRUCTURAL* VEHICULAR
PAVEMENT
SIDEWALKS LANDSCAPE/UNPAVED
% MAXIMUM DRY
DENSITY [98%] [98%] [98%] [95%] [85% IN UPPER
2']
NEW BUILDING
FFE = 224.00
B4/C4
4.5:1
MINOR CONTOUR
ST STORM DRAINAGE
PIPING (15"Ø OR LESS)
TOP OF CURB
BOTTOM OF CURB
MAJOR CONTOUR
SPOT ELEVATION
STORM DRAINAGE
PIPING (18"Ø OR MORE)
FL = 219.04
FL = 220.00
FL = 220.375
224.00
224.00
224.00
224.00
224.00
GRADING NOTES:
1. ALL EXCESS SOIL MATERIAL EXCAVATED AS A PART OF THE
PROJECTS SHALL BE DISPOSED OF ON BASE. COORDINATE
DISPOSAL LOCATION WITH W.C.E
STORM DRAINAGE NOTES:
1. THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS ON ALL STORM PIPE MATERIALS TO LBYD PRIOR TO INSTALLATION
AND/OR FABRICATION.
2. ALL PROPOSED STORM INLETS (GRATES, CURB, YARD, AREA DRAINS) ARE TO BE LOCATED AT THE LOWPOINTS. GRADING
SHALL BE TO DIRECT RUNOFF TO THESE INLETS. NOTIFY LBYD OF ANY DISCREPANCIES.
3. STORM DRAINAGE SYSTEMS SHALL BE CONSTRUCTED FROM DOWNSTREAM TO UPSTREAM. VERIFY ALL PIPE SLOPES, INVERTS, AND POINTS OF CONNECTION PRIOR TO CONSTRUCTION. NOTIFY LBYD OF ANY DISCREPANCIES.
4. THE CONTRACTOR SHALL VERIFY ALL EXISTING AND PROPOSED STORM PIPE GRADES AND POINTS OF CONNECTION PRIOR
TO INSTALLATION. LBYD SHALL BE NOTIFIED OF ANY DEVIATIONS PRIOR TO CONSTRUCTION.
5. PROPOSED STORM PIPES 30" AND LESS SHALL BE BEDDED IN 4" OF CRUSHED AGGREGATE AND STORM PIPES 36" AND
GREATER SHALL BE BEDDED IN A 6" OF CRUSHED AGGREGATE.
6. ALL STORM PIPES 15" AND LESS SHALL BE SMOOTH LINED SCH 40 POLYVINYL CHLORIDE (PVC) WITH WATER-TIGHT JOINTS
UNLESS OTHERWISE NOTED, INSTALLED PER MANUFACTURERS RECOMMENDATIONS
7. CONTRACTOR SHALL PROVIDE CAST IRON DOWNSPOUT BOOTS, CLEANOUTS AND COLLECTOR LINES FROM ALL EXTERIOR DOWNSPOUTS TO CONNECT TO PRIMARY STORM DRAINAGE SYSTEM. COORDINATE WITH EXTERIOR ELEVATIONS, ROOF AND PLUMBING PLANS FOR DOWNSPOUT LOCATIONS. COORDINATE DOWNSPOUT MODEL NUMBER WITH THE ARCHITECT.
8. CONTRACTOR SHALL COORDINATE ROOF DRAIN COLLECTOR LINES, DOWNSPOUTS AND BOOTS WITH FOOTING ELEVATIONS ON THE STRUCTURAL PLANS PRIOR TO POURING FOOTINGS. TOP OF FOOTINGS SHALL BE A MINIMUM OF 3' BELOW GRADE AT ALL ROOF DRAIN DOWNSPOUT LOCATIONS TO ENSURE ADEQUATE COVER TO TRANSITION TO BELOW GRADE PIPING.
219.76
219.76
218.99
218.99
223.76
223.76
219.76
219.76
223.76
223.76
223.93
223.93
223.93
223.93
223.93
223.93
223.82
223.89
223.89
223.89
223.89
223.89
223.89
223.82
223.82
223.81 223.81
224.40
224.40
MATCH LIMITS OF ACCESSIBLE PARKING
CONCRETE PAVING TO EXISTING ASPHALT.
DO NOT EXCEED 2% SLOPE IN ANY
DIRECTION IN CONCRETE PAVING AREA
TIE TO EXISTING GRATE INLET.
INV = 218.74
6" PVC SCH40 ROOF
DRAIN LINE @ 1.0
MINIMUM SLOPE
(TYP)
57 LF 6" PVC SCH40
STORM LINE @ 1.5%
SLOPE
50 LF 6" PVC SCH40
STORM LINE @ 1.5%
SLOPE
65 LF 6" PVC SCH40
STORM LINE @ 1.5%
SLOPE
11 LF 6" PVC SCH40
STORM LINE @ 1.5%
SLOPE
FL = 220.86
223.91
223.93
224.00
223.97
223.97
223.97
223.97
219.00
219.09
223.86
223.93
20 LF 6" PVC SCH40
STORM LINE @ 1.5%
SLOPE
(8) 6" RISERS
223.90 223.90
224.6 224.6
225.01 M.E. 225.1 M.E.
(8) 6" RISERS
N
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
2" W
2" W
2" W
" W
2" W
6" F
6" F
6" F
" F
6" F
4" SS
4" SS
4"
SS
4"
SS
4" SS
4" SS
CO
CO
CO
CO
CO
0 22
ST
ST
ST
ST
ST
ST
ST
COMM
CO
MM
SCALE: 1"=10'
10 20
5 15
N
UTILITY NOTES:
1. CONTRACTOR TO COORDINATE WITH OWNER PRIOR TO ANY DEMOLITION REGARDING ITEMS TO BE SALVAGED, RECYCLED, AND REUSED. CONTRACTOR SHALL REMOVE ITEMS TO BE SALVAGED WITH EXTREME CAUTION TO PREVENT DAMAGE.
CONTRACTOR SHALL TURN ALL SALVAGED ITEMS OVER TO OWNER.
2. THE SITE CONTRACTOR IS RESPONSIBLE FOR COMPLETING ALL UTILITY SERVICES (WATER, SEWER, GAS, ELECTRICAL, TELEPHONE, CABLE TV) FROM THE POINT THE RESPECTIVE UTILITY COMPANY COMPLETES THEIR WORK TO THE POINT OF
CONNECTION AT THE BUILDING.
3. REFER TO ARCHITECTURAL, MECHANICAL, PLUMBING, ELECTRICAL, ETC. PLANS FOR ALL PROPOSED UTILITY POINTS OF
CONNECTION AT THE BUILDING. NOTIFY ARCHITECT, LBYD OF ANY DISCREPANCIES.
4. GRAVITY SEWER SYSTEMS SHALL BE CONSTRUCTED FROM DOWNSTREAM TO UPSTREAM. VERIFY ALL PIPE SLOPES, INVERTS, AND POINTS OF CONNECTION PRIOR TO CONSTRUCTION. NOTIFY LBYD OF ANY DISCREPANCIES.
5. THE CONTRACTOR SHALL VERIFY ALL EXISTING AND PROPOSED GRAVITY SEWER PIPE GRADES AND POINTS OF CONNECTION PRIOR TO INSTALLATION. LBYD SHALL BE NOTIFIED OF ANY DEVIATIONS PRIOR TO CONSTRUCTION.
6. BACKFLOW PREVENTION AND METERING SHALL INSIDE THE BUILDING. REFERENCE PLUMBING AND FIRE PROTECTION DRAWINGS FOR DETAILS WATER SERVICES 4 INCHES IN DIAMETER AND GREATER SHALL BE DIP(CL.350) AND WATER SERVICES LESS THAN 3 INCHES IN DIAMETER SHALL BE TYPE "K" COPPER UNLESS OTHERWISE INDICATED ON THE PLANS.
7. WATER MAINS AND SERVICES SHALL BE A MINIMUM OF 10 FEET HORIZONTAL AND 2 FEET VERTICAL FROM ALL SANITARY
SEWER MAINS AND LATERALS.
8. WATER MAINS AND SERVICES SHALL BE INSTALLED IN ACCORDANCE WITH THE LOCAL UTILITY COMPANY'S REQUIREMENTS.
ALL MAINS AND SERVICES SHALL BE INSTALLED WITH A MINIMUM OF 36" COVER UNLESS OTHERWISE INDICATED ON PLANS.
9. ALL SANITARY SEWER MAINS AND LATERALS SHALL BE DIP CL350 UNLESS OTHERWISE REQUIRED BY THE LOCAL UTILITY
COMPANY.
10. ALL UNDERGROUND [ELECTRICAL, TELEPHONE, AND CABLE TV] SHALL BE INSTALLED IN PVC CONDUIT OR CONCRETE ENCASED DUCT BANK WITH PULL WIRE MEETING THE LOCAL UTILITY COMPANY'S REQUIREMENTS. INFORMATION SHOWN ON CIVIL DRAWINGS FOR REFERENCE ONLY. REFER TO ELECTRICAL PLANS FOR SPECIFIC INFORMATION.
11. UTILITY TRENCHES SHALL BE BACKFILLED WITH COMPACTED FILL PLACED IN 6 INCH LOOSE LIFTS. FILL SHALL BE
COMPACTED TO 98% STANDARD PROCTOR AND OPTIMUM MOISTURE CONTENT WITHIN ±2.0%.
12. WHEN INSTALLING UTILITIES IN EXISTING PAVED AREAS OR IN AREAS WHERE SOILS ARE CONSIDERED UNSUITABLE FOR BEDDING OR BACKFILLING, UTILITY TRENCHES SHALL BE BACKFILLED FULL DEPTH WITH CRUSHED AGGREGATE.
13. WHERE UTILITIES ARE TO BE INSTALLED IN AREAS OF EXISTING [PAVING, HARDSCAPE, SIDEWALKS, ETC.] CONTRACTOR SHALL SAWCUT AND REMOVE EXISTING [PAVING, HARDSCAPE, SIDEWALK ETC.] AND REPLACE IN LIKE KIND AND RESTRIPE
AS NECESSARY. BACKFILL TRENCH FULL DEPTH WITH STONE.
14. CONTRACTOR IS RESPONSIBLE FOR ADJUSTING ELEVATIONS OF ALL AT-GRADE STRUCTURES AND UTILITIES TO REMAIN
(VALVE BOXES, MANHOLES, INLETS, VAULTS, ETC) TO MATCH PROPOSED FINISHED GRADES.
15. CONTRACTOR IS RESPONSIBLE FOR PROVIDING TAMPER SWITCHES AND ASSOCIATED CONDUIT, WIRING, ETC ON FIRE SERVICE POST INDICATOR VALVES AND VALVES IN PIT MOUNTED FIRE BACKFLOW PREVENTOR ASSEMBLIES. COORDINATE
WITH FIRE PROTECTION AND ELECTRICAL PLANS.
16. PROVIDE 4" DIP CL 350 GRAVITY DRAIN LINE FROM ALL BELOW GRADE UTILITY VAULTS TO THE NEAREST STORM DRAINAGE
INLET OR DAYLIGHT AT GRADE.
FL = 221.00
FL = 220.24
FL = 218.92
EXISTING SANITARY SEWER MANHOLE
INV IN = 217.21
COMMUNICATIONS LINE TO NEW
HANDHOLE (SHOWN FOR
REFERENCE ONLY, SEE ELECTRICAL)
6" DIP CL350 FIRE SERVICE LINE
2" TYPE K COPPER
DOMESTIC WATER LINE
4" DIP CL 350 SANITARY SEWER LINE
@ 1.5% SLOPE
FIRE SERVICE F
DOMESTIC WATER W
COMMUNICATION
SANITARY SEWER SS
COMM
FIRE HYDRANT
SANITARY SEWER
MANHOLE
CLEANOUTCO
IRRIGATION SERVICEIRR
112 LF 4" DIP CL 350 SANITARY
SEWER LINE @ 1.5% SLOPE
85 LF 4" DIP CL 350 SANITARY
SEWER LINE @ 1.5% SLOPE
54LF 4" DIP CL 350 SANITARY SEWER
LINE @ 1.5% SLOPE
NEW BUILDING
FFE = 224.00
B5/C5
POST INDICATOR VALVE
WITH TAMPER SWITHCES
(SEE DETAIL)
2" GATE VALVE (SEE
DETAIL)
SECONDARY CONDUCTORS
(SEE ELECTRICAL)
CONNECT TO EXISTING WATER LINE
WITH CUT-IN-TEE CONNECTIONS
MATCH EXISTING WATER LINE SIZE.
(SEE SPECIAL NOTE #2)
SEE PLUMBING AND FIRE
PROTECTION DRAWINGS FOR WATER
LINE CONTINUATION TO BUILDING
NEW LIGHT POLE (SEE
ELECTRICAL)
NEW LIGHT POLE (SEE
ELECTRICAL)
" R
CP
6" CLAY
" P
VC
" R
CP TO 12
" P
VC
0 22
ST
ST
ST
ST
ST
ST
ST
SCALE: 1"=10'
10 20
5 15
N
EROSION CONTROL NOTES:
1. SITE EROSION CONTROL MEASURES SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE, AND LOCAL LAWS, CODES, AND
REGULATIONS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A "NOTICE OF INTENT"(NOI) FROM ADEM THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MONITORING, INSPECTIONS, ETC. TO ENSURE THE OWNER THAT THE SITE IS AT ALL TIMES IN ACCORDANCE WITH ADEM RULES & REGULATIONS. DOCUMENTATION OF INSPECTIONS BY A Q.C.I. OR Q.C.P. SHALL BE MAINTAINED BY THE CONTRACTOR AND PROVIDED TO THE OWNER AT HIS/HER REQUEST. ANY AND ALL FEES, FINES, ETC., SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
3. ALL EROSION CONTROL DEVICES SHALL BE PROPERLY MAINTAINED DURING THE CONSTRUCTION PROCESS AND UNTIL ALL DISTURBED AREAS HAVE BEEN PERMANENTLY STABILIZED. ALL EROSION CONTROL INSTALLATION AND MAINTENANCE SHALL BE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
4. EROSION CONTROL DEVICES SHOWN ON THESE PLANS ARE A MINIMUM AND ARE DEPENDENT ON THE CONTRACTOR'S CONSTRUCTION PHASING OF THE PROJECT. ADDITIONAL DEVICES SHALL BE INSTALLED AS REQUIRED TO PREVENT SILTATION, EROSION AND OTHER DEGRADATION OR POLLUTION TO THE SITE OR ADJACENT PROPERTIES, STREAMS, DITCHES, AND PUBLIC ROADWAYS. ADDITIONAL MEASURES MAY INCLUDE, AS MINIMUM, TEMPORARY SEDIMENT BASINS, CONSTRUCTION EXITS PAD, VEHICLE WASH RACKS, SILT FENCING, STRAW AND RIP RAP CHECK DAMS, DIVERSION DITCHES, ETC. THESE ADDITIONAL MEASURES SHALL BE AT NO ADDITIONAL COST TO THE OWNER.
5. EROSION CONTROL DEVICES SHALL INCLUDE, BUT NOT LIMITED, TO THE FOLLOWING DEVICES: SILT FENCING, BRUSH BERMS, SEDIMENT BASINS, DETENTION PONDS, STRAW WATTLES , CHECK DAMS, FILTER BERMS, JUTE MATTING, VEGETATIVE FILTER STRIPS, TURF REINFORCEMENT MAT, DIVERSION BERMS, ETC.
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ALL EROSION CONTROL DEVICES IN GOOD OPERATING CONDITION DURING ALL LAND DISTURBING ACTIVITIES. THIS RESPONSIBILITY SHALL INCLUDE THE CLEANUP AND/OR
REPAIRS TO THE DEVICES AT NO ADDITIONAL COST TO THE OWNER.
7. EROSION CONTROL DEVICES SHALL BE MONITORED AND MAINTAINED UNTIL THE SITE HAS BEEN PERMANENTLY STABILIZED AND AFTER EACH RAINFALL GREATER THAN 0.75 INCHES IN A 24 HOUR PERIOD, ANY WIND GUSTS GREATER THAN 25 MPH, AND ANY SUSTAINED WINDS GREATER THAN 20 MPH IN A 24 HOUR PERIOD.
8. AFTER ALL LAND DISTURBANCE ACTIVITIES HAVE CEASED AND AFTER ALL DISTURBED AREAS HAVE BEEN PERMANENTLY STABILIZED, THE EROSION CONTROL DEVICES SHALL BE REMOVED BY THE CONTRACTOR AND THE AREA CLEANED AND
DRESSED.
9. DEWATERING OPERATIONS MAY NOT BE DISCHARGED IN A MANNER THAT CAUSES EROSION OF THE SITE OR POLLUTION TO
ADJACENT PROPERTIES, STREAMS, DITCHES, OR PUBLIC ROADWAYS.
10. A GRAVELED ACCESS DRIVE OF SUFFICIENT SIZE SHALL BE AT EACH SITE ENTRANCE/EXIT TO PREVENT TRACKING OF DIRT AND SEDIMENT ONTO PUBLIC OR PRIVATE ROADWAYS. IF SEDIMENT REACHES THE ROADWAY, THEN IT MUST BE CLEANED
AT THE END OF EACH WORKDAY.
11. ALL LAND DISTURBANCE ACTIVITIES SHALL BE CONDUCTED IN A LOGICAL SEQUENCE TO MINIMIZE THE EXPOSURE OF BARE
AREAS AT ANY ONE TIME.
12. ALL DISTURBED AREAS LEFT INACTIVE FOR MORE THAN 13 DAYS SHALL BE SEEDED AND MULCHED IN ACCORDANCE WITH
[ALDOT SPECIFICATIONS SECTION 652 AND 656.]
13. ALL PREVIOUSLY GRADED AREAS SHALL RECEIVE 4 INCHES OF TOPSOIL AND PERMANENT GRASSING UNLESS OTHERWISE
INDICATED ON THE LANDSCAPE PLAN.
14. PRIOR TO SITE CLEARING, ALL PERIMETER SILT FENCING, BRUSH BERMS, ETC. AND GRAVELED ACCESS DRIVES SHALL BE
INSTALLED.
NEW BUILDING
FFE = 224.00
B6/C6
SILT FENCINGSB
WIP
CEP
WATTLE INLET PROTECTION
CONSTRUCTION EXIT PAD
TOPSOIL
SS
ECB
DV
PS
TS
SOD
MU
EROSION CONTROL BLANKET
DIVERSION BERM
PERMANENT SEEDING
TEMPORARY SEEDING
SODDING
MULCHING
SB
SB
SB
TS
MU
TS
MU
TS
MU
TS
MU
TS
MU
TS
MU
TS
MU
TS
MU
WIP
WIP
SOD
SOD
ECB
ECB
ECB
ECB
VEHICLE FUELING AND
MAINTENANCE AREA
PROJECT SIGN
PROJECT RAIN GAUGE
CEP
VEHICLE WASHDOWN AREA
CONCRETE
WASHOUT AREA
SILTSOXX
TSG
SS
SB
SB
SB
SB
TSG
PS
TSG
PS
TSG
PS
TSG
PS
TSG
PS
TSG
PS
TSG
PS
TSG
PS
WIP
B7/C7
FLOW
SURFACE FLOW
12" WATTLE
SURFACE FLOW
SURFACE FLO
W
WOOD STAKE
DETAIL 1
DIRECTION (TYPICAL)
STORM SEWER
DROP INLET
WOOD STAKE
SEE DETAIL 2 STORM SEWER
DROP INLET
DIRECTION (TYPICAL)
DIRECTION (TYPICAL)
ANCHOR THROUGH NETTING
ANCHOR THROUGH
NETTING
STORM SEWER CURB INLET
PLAN VIEW
WOOD STAKE
CHANNEL BOTTOM
WOOD STAKE
WOOD STAKE TO
ONLY PENETRATE
NETTING, NOT
CORE MATERIAL
STAKE DETAIL 1
FLOW
STAKE DETAIL 2
2'
MI
N
2'
MI
N
WOOD STAKE TO ONLY PENETRATE
NETTING, NOT CORE MATERIAL
NOTE:
WATTLES MAY BE A STRAW
WATTLE, A CURLEX SEDIMENT
LOG, OR APPROVED EQUAL.
MAINTENANCE SCHEDULE:
REMOVE SEDIMENT DEPOSITS PROMPTLY AFTER IT HAS ACCUMULATED TO 1/2 OF THE ORIGINAL CAPACITY, TAKING CARE NOT TO UNDERMINE THE ENTRENCHED WATTLES. INSPECT PERIODICALLY
FOR DETERIORATION OR DAMAGE FROM CONSTRUCTION ACTIVITIES. REPAIR DAMAGED BARRIER
IMMEDIATELY.
12" WATTLE
12" WATTLE 12" WATTLE
12" WATTLE
WATTLE INLET RPOTECTION
N.T.S.
C-6
DROP INLET PROTECTION
CURB INLET PROTECTION
WIP
GEOTEXTILE
PIN GEOTEXTILE
AT INLET 5" O.C.
EXTEND GEOTEXTILE
1' BEYOND WATTLE
GEOTEXTILE
ROLL NO. 1
ROLL NO. 2
ROLL NO. 3
5'
INSTALLATION:
1. START AT DOWNSTREAM TERMINAL AND PROGRESS UPSTREAM.
2. FIRST ROLL IS CENTERED LONGITUDINALLY IN MID CHANNEL AND PINNED WITH TEMPORARY
STAKES TO MAINTAIN ALIGNMENT.
3. SUBSEQUENT ROLLS FOLLOW IN STAGGERED SEQUENCE BEHIND FIRST ROLL. USE CENTER
ROLL FOR ALIGNMENT TO CHANNEL CENTER.
4. WORK OUTWARDS FROM CHANNEL CENTER TO EDGE.
5. USE 3" OVERLAP AND STAKE AT 5' INTERVALS ALONG SEAMS.
6. USE 3' OVERLAPS AND SHINGLE DOWNSTREAM TO CONNECT LINING AT ROLL ENDS.
7. ANCHOR PRODUCTS SO THAT A CONTINUOUS, FIRM CONTACT (NO TENTING) WITH THE SOIL
SURFACE/SEED BAD IS MAINTAINED.
SEQUENTIAL ROLL RUN OUT
IN CHANNELS
3' OVERLAP
5'
PICTORIAL VIEW OF TRANSVERSE SLOT
9"STAKE
6"
38"
MAINTENANCE
INSPECT AFTER STORM EVENTS UNTIL VEGETATION IS ESTABLISHED
FOR EROSION OR UNDERMINING BENEATH BLANKETS. IF ANY AREA
SHOWS EROSION, PULL BACK THAT PORTION OF THE BLANKET, ADD
TAMPED SOIL AND RESEED; THEN RESECURE THE BLANKETS
IF BLANKETS SHOULD BECOME DISLOCATED OR DAMAGED, REPAIR
OR REPLACE AND RESECURE IMMEDIATELY.
EROSION CONTROL BLANKET
N.T.S.
C-6ECB
FRONT VIEW
6" MIN. TRENCH
10' MAX O.C.
SIDE VIEW
FLOW
" M
IN
" M
IN
" M
IN
" M
IN
SPECIAL NOTES:
1. SILT FENCE FABRIC SHALL BE PER TABLE SB-1 FROM THE LATEST ALABAMA EROSION
CONTROL HANDBOOK.
2. USE D.O.T. APPROVED WOVEN WIRE FENCE.
3. USE 5' MIN. STEEL POSTS (1.3 LB/FT MIN.).
WOVEN WIRE
FENCE BACKING
"-3
2" M
IN
STEEL POSTS
GROUND LINE
STEEL POST
WOVEN WIRE FENCE
GEOTEXTILE FABRIC
GROUND LINE
COMPACTED SOIL
6" MIN.6"
M
IN
NOTES:
1. THE WOVEN WIRE FENCING SHALL BE FASTENED TO THE UPSTREAM SIDE OF POSTS
BY STAPLES OF WIRE TIES.
2. GEOTEXTILE FABRIC SHALL BE SECURELY FASTENED TO THE WOVEN WIRE FENCING.
MAINTENANCE SCHEDULE:
REMOVE SEDIMENT DEPOSITS WHEN THEY REACH A DEPTH OF 15" OR 1/2 THE HEIGHT
OF THE FENCE AS INSTALLED TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE
NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. SHOULD THE FABRIC OR SILT
FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT
PROMPTLY.
(TYPE A)
SILT FENCE - TYPE A
N.T.S.
C-6SB
LOOP GEOTEXTILE FABRIC
OVER POSTS AND WIRE
FASTENER
"-3
2" M
IN
HOGWIRE FASTENERS
EVERY 2'
BERM
BERM
BE
RM
3:1
3:1 3:1
3:1
B
OR AS REQUIRED TO
CONTAIN WASTE CONCRETE
SECTION B
SECTION A
CONCRETE WASHOUT AREA INSTALLATION NOTES
1. THE CONCRETE WASHOUT AREA SHALL BE INSTALLED PRIOR TO ANY
CONCRETE PLACEMENT ON SITE.
2. SIGNS SHALL BE PLACED AT THE CONSTRUCTION ENTRANCE, AT THE
WASHOUT AREA, AND ELSEWHERE AS NECESSARY TO CLEARLY
INDICATE THE LOCATION OF THE CONCRETE WASHOUT AREA TO
OPERATORS OF CONCRETE TRUCKS AND PUMP RIGS.
3. EXCAVATED MATERIAL SHALL BE UTILIZED IN PERIMETER BERM
CONSTRUCTION.
4. IMPERMEABLE PLASTIC SHEETING SHALL BE 30 MIL TO PREVENT ANY
TEARING, PUNCTURES, OR LEAKING.
CONCRETE WASHOUT AREA MAINTENANCE NOTES
1. THE CONCRETE WASHOUT AREA SHALL BE REPAIRED AND
ENLARGED OR CLEANED OUT AS NECESSARY TO MAINTAIN CAPACITY
FOR WASTED CONCRETE.
2. AT THE END OF CONSTRUCTION, ALL CONCRETE SHALL BE REMOVED
FROM THE SITE AND DISPOSED OF AT AN APPROVED WASTE SITE.
3. WHEN THE CONCRETE WASHOUT AREA IS REMOVED, THE DISTURBED
AREA SHALL BE SEEDED AND MULCHED OR OTHERWISE STABILIZED.
4. INSPECT WEEKLY, DURING AND AFTER ANY STORM EVENT.
SIGN
8'x8' MIN.
IMPERMEABLE
PLASTIC
MEMBRANE
8'x8' MIN.
12" MIN.
3:1 OF FLATTER
SIDE SLOPES
GROUND SURFACE
IMPERMEABLE PLASTIC MEMBRANEBERM AROUND
PERIMETER
2'-0" MIN.
COMPACTED EMBANKMENT
MATERIAL (TYP.)
CONCRETE WASHOUT AREA
N.T.S.
C-6
VW
15' MIN
50' MIN
1" TO 2 12" SIZE COARSE AGGREGATE
8" M
IN
GROUND SURFACE
1.0%
MIN
NOTE:
1. SEE SILT FENCE DETAIL FOR INSTALLATION
2. SEE DETAIL FOR WATTLE CHECK DAM
INSTALLATION
SILT FENCE
WATTLE
CHECK DAM
DIVERSION BERM
VEHICLE WASHDOWN AREA
N.T.S.
C-6
NOTES:
1. ANY DISTURBED AREA SHALL, WITHIN FOURTEEN (14) DAYS OF
STOPPING WORK, BE PLANTED OR OTHERWISE PROVIDED WITH
GROUND COVER, MATERIALS, DEVICES, AND/OR STRUCTURES
SUFFICIENT TO RESTRAIN ALL FORMS OF EROSION, TO THE
MAXIMUM EXTENT PRACTICABLE.
2. CONTRACTOR TO COORDINATE PERMANENT SEEDING WITH
OWNER.
TABLE MU-1
MULCHING MATERIALS AND
APPLICATION RATES
MATERIAL RATE PER ACRE
(PER 1,000 SQ.FT.
NOTES
STRAW WITH
SEED
1 1/2 - 2 TONS
(70 LBS - 90 LBS)
SPREAD BY HAND OR MACHINE TO ATTAIN 75%
GROUNDCOVER; ANCHOR WHEN SUBJECT TO
BLOWING.
STRAW ALONE
(NO SEED)
2 1/2 - 3 TONS
(115 LBS - 160 LBS)
SPREAD BY HAND OR MACHINE; ANCHOR WHEN
SUBJECT TO BLOWING.
WOOD CHIPS 5-6 TONS
(225 LBS - 270 LBS)
TREAT WITH 12 LBS. NITROGEN/TON.
BARK 35 CUBIC YARDS
(0.8 CUBIC YARD)
CAN APPLY WITH MULCH BLOWER.
PINE STRAW 1-2 TONS
(45 LBS - 90 LBS)
SPREAD BY HAND OR MACHINE; WILL NOT BLOW
LIKE STRAW.
PEANUT HULLS 10-20 TON
(450 LBS - 900 LBS)
WILL WASH OFF SLOPES. TREAT WITH 12 LBS.
NITROGEN/TON.
TABLE TS-1
COMMONLY USED PLANTS FOR TEMPORARY COVER
SPECIES SEEDING RATE
PER AC PLS
NORTH CENTRAL SOUTH
MILLET, BROWNTOP, OR
GERMAN
40 LBS MAY 1 -
AUG 1
ARP 1 -
AUG 15
APR 1 -
AUG 15
RYE 3 BU SEPT 1 -
NOV 15
SEPT 15 -
NOV 15
SEPT 15 -
NOV 15
RYEGRASS 30 LBS AUG 1 -
SEPT 15
SEPT 1 -
OCT 15
SEPT 1 -
OCT 15
SORGHUM - SUDAN HYBRIDS 40 LBS MAY 1 -
AUG 1
APR 15 -
AUG 1
APR 1 -
AUG 15
SUNDANGRASS 40 LBS MAY 1 -
AUG 1
APR 15 -
AUG 1
APR 1 -
AUG 15
WHEAT 3 BU SEPT 1 -
NOV 1
SEPT 15 -
NOV 15
SEPT 15 -
NOV 15
COMMON BERMUDAGRASS 10 LBS APR 1 -
JULY 1
MAR 15 -
JULY 15
MAR 1 -
JULY 15
CRIMSON CLOVER 10 LBS SEPT 1 -
NOV 1
SEPT 1 -
NOV 1
SEPT 1 -
NOV 1
TABLE PS-1
COMMONLY USED PLANTS FOR PERMANENT
COVER WITH SEEDING RATES AND DATES
SPECIES SEEDING RATE
PER AC PLS
NORTH CENTRAL SOUTH
BAHIAGRASS,
PENSACOLA
40 LBS -- MAR 1 -
JULY 1
FEB 1 -
NOV 1
BERMUDAGRASS,
COMMON
10 LBS APR 1 -
JULY 1
MAR 15 -
JULY 15
MAR 1 -
JULY 15
BAHIAGRASS,
PENSACOLA
BERMUDAGRASS,
COMMON
30 LBS
5 LBS
-- MAR 1 -
JULY 1
MAR 1 -
JULY 15
BERNUDAGRASS,
HYBRID (LAWN TYPES)
SOLID SOD ANYTIME ANYTIME ANYTIME
BERNUDAGRASS,
HYBRID (LAWN TYPES)
SPRIGS
1/SQ FT
MAR 1 -
AUG 1
MAR 1 -
AUG 1
FEB 15 -
SEPT 1
FESCUE, TALL 40 - 50 LBS SEPT 1 -
NOV 1
SEPT 1 -
NOV 1
SERICEA 40 - 60 LBS MAR 15 -
JULY 15
MAR 1 -
JULY 15
FEB 15 -
JULY 15
SERICEA & COMMON
BERMUDAGRASS
40 - 60 LBS
10 LBS
MAR 15 -
JULY 15
MAR 1 -
JULY 15
FEB 15 -
JULY 15
SWITCHGRASS, ALAMO 4 LBS APR 1 -
JUN 15
MAR 15 -
JUN 15
MAR 15 -
JUN 15
PLS MEANS PURE LIVE SEED AND IS USED TO ADJUST SEEDING RATES. FOR EXAMPLE:
TO PLANT 10 LBS PLS OF A SPECIES WITH GERMINATION OF 80% AND 10% INERT MATERIAL
-> 10 LBS / 0.70 = 14.3 LBS.
N.T.S.
MULCHING, TEMPORARY SEEDING, &
PERMANENT SEEDING DIRECTIONS
SECTION
FLOW
CONCRETE BLOCKS OR SAND BAGS
SIZED AS NEEDED (10' O.C.)
SiltSoxx TM (8",12", or 18" TYP)
EXISTING GRADE
PAVEMENT OR
IMPERVIOUS SURFACE
CONCRETE BLOCKS OR SAND BAGS
SIZED AS NEEDED (10' O.C.)
WATER FLOW
WORK AREA
SILTSOXX (8", 12", 18" TYP)
NOTES:
1. ALL MATERIAL TO MEET SPECIFICATIONS.
2.FILTER MEDIA TO MEET APPLICATION
REQUIREMENTS.
3.FILTER MEDIA TO BE DISPERSED ON SITE,
AS DETERMINED BY ENGINEER.
PLAN
SiltSoxxTM for Sediment Control on Pavement N.T.S.
C-6
C-6
B8/C8
CONCRETE WALK SECTION
CONTRACTION JOINT
1/8"
VARIES
1/4" PER FOOT CROSS SLOPE
(UNLESS OTHERWISE SHOWN)
NOTES:
1. CONTRACTION (SAW CUT) JOINTS TO BE EVERY 5 TO 8 FEET WITH A MAXIMUM
SPACING OF TWICE THE SLAB THICKNESS IN FEET; CUT TO A DEPTH OF 1''
MINIMUM TO 1 13 '' MAXIMUM.
2. CUT CONTRACTION JOINTS BETWEEN 2 HOURS AND 12 HOURS OF CONCRETE
PLACEMENT.
3. PLACE ISOLATION JOINTS WHEN ADJACENT TO BUILDINGS, CURBS, ETC. USE A 12"
THICK PRE-MOULDED EXPANSION JOINT FILLER CONFORMING TO ASTM D1751 OR
D1752 TO CREATE A BOND BREAK. INSTALL JOINT SEALER OVER JOINT FILLER.
4. CONCRETE TO BE 4000 PSI COMPRESSIVE STRENGTH UNLESS OTHERWISE
NOTED.
5. PLACE SIDEWALK ON COMPACTED SUBGRADE- 98% STANDARD PROCTOR
DENSITY (ASTM D1557) UNLESS OTHERWISE NOTED.
FINISHED GRADE
4" CONCRETE PAVEMENT
R1/8"
TYPICAL SIDEWALK DETAIL
N.T.S.
C-3
4''
1" TO 11
3"
ISOLATION JOINT
1/2"
SEE NOTE 3
1" TYP.
SUB GRADE CAREFULLY PLACED AND
COMPACTED SELECTED EARTH
BEDDING IN 6" LAYERS
6"
MIN.6"
MIN.
VARIES
VA
RI
ES
DIA.
SELECT GRANULAR MATERIAL
(SEE SPECIFICATIONS)
SPRING LINE
1'
4" T
HI
CK
6"
T O
" P
IP
E
6" T
HI
CK
" A
ND
LA
RG
ER
P
IP
E
TYPICAL PIPE BEDDING AND INITIAL
BACKFILL UNDER UNIMPROVED SURFACES
N.T.S.
C-5
B
NOTE:
BASE SECTION SHALL BE SET ON FOUNDATION OF COMPACTED NO.
57 OR NO. 67 COMPACTED STONE AGGREGATE A MINIMUM OF 12"
THICKNESS AND COVERING THE ENTIRE BOTTOM OF THE
EXCAVATION FOR THE MANHOLE.
5" 4' DIAMETER 5"
4" MORTER
D"
INVERTAPPROVED NON-SHRINKING GROUT
6" MI
N.
"D" (FOR LARGEST PIPE
ENTERING MANHOLE)
6" MIN. (IF MANHOLE HEIGHT IS
GREATER THAN 10' MIN. BASE
SECTION THICKNESS SHALL BE 12")
D/
SECTION A-A
FACTORY CAST OPENINGS
MIN. 2" CLEARANCE IS REQUIRED
ON ALL INCOMING PIPES.
SERVICE LINE
DEFLECTION ANGLE
PLACE STEPS ON LEAST
OBSTRUCTED WALL
THE INVERT OF ALL LATERAL PIPES
SHALL BE SET AT THE SPRING
LINE OF THE OUTFALL PIPE
OR AS INDICATED IN THE PLANS.
FINISHED GRADE
NOTE:
PRECAST SECTION
SHALL BE REINFORCED
AS PER ASTM C478
TOP OF PAVEMENT
MANHOLE FRAME AND COVER
PER LOCAL STANDARDS
3'
2'
MA
X.
1'- 4"
(T
YP
PRECAST
RISER
SECTIONS
5" 4' 5" MANHOLE STEPS
(PER LOCAL STANDARDS)
VA
RI
AB
LE
D
D
2'
MA
X.
A
TYPICAL
LATERAL
PIPE
SPRING
LINEB
APPROVED NON-SHRINKING
GROUT
FL IN
FL OUT1" MI
N.D/
A
SECTION
SECTION B-B
SANITARY SEWER MANHOLE
N.T.S.
C-5
SOIL BEARING LOAD
P.S.F.
SOIL BEARING LOAD
MUCK
SOFT CLAY
SILT
SANDY SILT
SAND
SANDY CLAY
HARD PAN
1,000 1,500 3,000 4,000 6,000 9,000
*BASED ON 150 PSI TEST PRESSURE
20" 18" 16" 14" 12" 10" 8" 6" 4"
THRUST AT FITTINGS IN POUNDS*
PIPE SIZE 90° BEND
2,666 5,998
10,663 16,661 23,992 32,655 42,652 53,981 66,643
45° BEND
1,443 3,246 5,771 9,017
12,984 17,673 23,083 29,214 36,067
22.5° BEND
1,655 2,942 4,597 6,619 9,010
11,768 14,893 18,387
TEE OR PLUG
1,885 4,241 7,540
11,781 16,965 23,091 30,160 38,170
47,124WIDTH OF THRUST BLO
CK
DE
PT
H
OF
TH
RU
ST
B
LO
CK
END AREA OF THRUST BLOCK
(IN SQUARE FEET) = ---------------------------------------------------
SOIL BEARING LOAD (AT FITTING)
THRUST (AT FITTING)
24" 95,966 51,937 26,477 67,858
X 1.5
NOTE: THE WIDTH OF THE THRUST
BLOCK SHALL BE 2X THE DEPTH OF THE
THRUST BLOCK.
UNDISTURBED SOIL
3000 P.S.I. CONCRETE
THRUST
BLOCK THRUST BLOCK
WATER MAIN
TYPICAL THRUST BLOCK
N.T.S.
C-5
18"
SQUARE
CONCRETE
4" D.I.P.
4" - 30° D.I. BEND
4" X D" D.I. WYE
D"
3"
ENCASE WYE IN CONCRETEIF LINE ENDS AT THIS
POINT, A PLUG SHALL BE
INSTALLED IN THE BELL.
9"
JOSAM #58900 CLEANOUT C.I.
FERRULE AND BRASS PLUG
MI
NI
MU
M
CO
VE
R
SE
E
SP
EC
IF
IC
AT
IO
NS
TYPICAL CLEANOUT
N.T.S.
C-5
1'-6" SQUARE
6"
VARIABLE
VA
RI
AB
LE
FINISH GRADE
# 4 BARS PLACED IN
CENTER EACH WAY
4,000 PSI CONCRETE
ADJUSTABLE VALVE BOX
TYPICAL GATE VALVE
N.T.S.
C-5
FINISHED GRADE
AL
L P
IV
'S
S
TD
. H
T.
AS
P
ER
F
IR
E
CO
DE
MUELLER CO. ADJUSTABLE TYPE
INDICATOR POST, MODEL A-20800
OR APPROVED EQUAL WITH TAMPER
SWITCHES. COORDINATE WITH
ELECTRICAL FOR MONITORING.
COMPACTED SOIL
MATERIAL
LE
NG
TH
T
O
SU
IT
B
UR
Y
D.I. PIPE
MUELLER CO. MODEL A-2052-16 PIV
OR APPROVED EQUAL.
TYPICAL POST
INDICATOR VALVE SETTING
N.T.S.
C-5
CONCRETE SIDEWALK DETAIL
WWR - SEE
SEE MECH. AND ELEC. DRAWINGS
#4@12 EW T&B
COORDINATE SIZE, NUMBER
AND LOCATION OF ANCHOR
RODS WITH EQUIP. SUPPLIER
#3@36 EW
1" ISOLATION
JOINT
1'-0"
EQUIPMENT PAD FOUNDATION DETAIL
N.T.S.
#4@12 EW T&B
1'-4" MIN
2'
MA
X
8" M
IN
2 #4 CONT.
HOOK BAR AT TURN DOWN SIDE #4 @ 12 DWLS
TURNDOWN SLAB END CONDITION
C-5
VARIES
STABLE SUBGRADE
APPROVED BY
GEOTECH
LOWER LIMIT OF
IMPROVED SURFACE
6"
MIN.
6"
MIN.
VA
RI
ES
DIA.
SELECT GRANULAR MATERIAL
(SEE SPECIFICATIONS)
SPRING LINE
1'
4" T
HI
CK
6"
T O
" P
IP
E
6" T
HI
CK
" A
ND
LA
RG
ER
P
IP
E
FINAL BACKFILL COMPACTED
MATERIAL PLACED IN 6" LAYERS
TYPICAL PIPE BEDDING AND INITIAL
BACKFILL UNDER IMPROVED SURFACES
N.T.