Attachment 2 - Fire Extinguishers Price Schedule.xlsx

XLSX spreadsheet 31 KB Posted

Attached to
Fire Extinguisher Maintenance, Testing, and Inspection Federal contract opportunity
Solicitation number
FA6648-22-Q-0006
Issued by
Department of the Air Force Reserve Command

About this file

This document contains a price schedule attachment for a federal solicitation seeking fire extinguisher maintenance, testing, and inspection services. The solicitation is seeking annual and periodic maintenance on a variety of portable fire extinguisher types including ABC, dry chemical, and halon and NOVEC flight line extinguishers. Services include inspection, maintenance, hydrostatic testing, recharging, repairs and labeling in accordance with NFPA 10 and other regulations. The price schedule outlines estimated quantities and unit pricing for required services across multiple contract line item numbers and multiple option years, and includes services such as annual inspection and maintenance, recharging, hydrostatic testing, repairs and emergency services. The solicitation is issued by the Department of the Air Force Reserve Command for requirements at Homestead Air Reserve Base.

View the file

Other files for this federal contract opportunity

Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLIN DETAILED

Fire Extinguishers FOR OFFICIAL USE ONLY
Portable /wheeled type Fire Extinguishersfrequencies for yr# of
fire extUnit PriceFY 22 (Basic Yr)# of
fire extUnit PriceFY 23 (Opt yr 1)# of
fire extUnit PriceFY 24(Opt Yr 2)# of
fire extUnit PriceFY 25 (Opt Yr 3)# of
fire extUnit PriceFY 26 (Opt Yr 4)6 Month ExtensionTotal Cost
4 Line Items (CLIN):UI: EA
BASE YEAR 0001UI: EA
OPTION LINE 1001UI: EA
OPTION LINE 2001UI: EA
OPTION LINE 3001UI: EA
OPTION LINE 4001Column1
CLIN0001Annual (Monthly) Insp/Maint
Annual Insp/Maint - ABC Extinguisher, 5 - 20 lbAnnual1100$ - 01100$ - 01100$ - 01100$ - 01100$ - 0
Annual Insp/Maint - Specialized Agent Hand Held ExtiguishersAnnual20$ - 020$ - 020$ - 020$ - 020$ - 0
Recharge Agent - Extinguishers 5 lbs.As required125$ - 025$ - 010$ - 025$ - 010$ - 0
Recharge Agent - Extinguishers 10 lbs.As required25$ - 0175$ - 0190$ - 0125$ - 0240$ - 0
Recharge Agent - Extinguishers 20 lbs.As required70$ - 070$ - 0190$ - 0180$ - 070$ - 0
Insp/Maint - Dry Chemical wheeled flight line extinguishers 125 lb.As required20$ - 020$ - 020$ - 020$ - 020$ - 0
Insp/Maint - Halon wheeled flight line extinguishers 150 lb.As required55$ - 055$ - 055$ - 055$ - 055$ - 0
Insp/Maint - NOVEC 1230 wheeled flight line extinguishersAs required20$ - 020$ - 020$ - 020$ - 020$ - 0
Insp/Maint - Chemical Facility Fire suppression systemsAs required2$ - 02$ - 02$ - 02$ - 02$ - 0
Insp/Maint - Hood and Duct System(s)As required8$ - 08$ - 08$ - 08$ - 08$ - 0
Fusible Links for Hood and Duct SystemsAs required48$ - 048$ - 048$ - 048$ - 048$ - 0
LabelingAs required1400$ - 01400$ - 01400$ - 01400$ - 01400$ - 0
Tamper SealsAs required1400$ - 01400$ - 01400$ - 01400$ - 01400$ - 0
Parts/Repair CostAs required300$ - 0300$ - 0300$ - 0300$ - 0300$ - 0
Recharge Agent/Nitrogen Flightline Extinguishers Halon/NOVECAs required35$ - 02$ - 03$ - 023$ - 011$ - 0
Recharge Wet/Dry Chemical Agent Cylinders/ExtinguishersAs required26$ - 030$ - 00$ - 00$ - 06$ - 0
Labor/Trip ChargeAs required10$ - 04$ - 04$ - 010$ - 010$ - 0
Unscheduled MaintenanceAs required1$ - 01$ - 010$ - 012$ - 010$ - 0
Tire repair/replacementAs required10$ - 020$ - 020$ - 020$ - 020$ - 0
TOTAL CLIN0001$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN00025 & 6 Yr
6-YR Maintaintenance -ABC Extinguisher, 5 - 10 lb6 Yr150$ - 0150$ - 0150$ - 0150$ - 0150$ - 0
6-YR Maintaintenance -ABC Extinguisher, 20 lb6 Yr50$ - 0150$ - 0150$ - 0150$ - 050$ - 0
5-6-YR Maintaintenance - Specialized Agents5 & 6 Yr4$ - 08$ - 04$ - 04$ - 02$ - 0
6-YR Maintaintenance - 125 lb. Dry Chemical6 Yr0$ - 00$ - 08$ - 03$ - 00$ - 0
6-YR Maintaintenance - Halon 150lb.6 Yr0$ - 00$ - 00$ - 010$ - 011$ - 0
6-YR Maintaintenance - NOVEC 12306 Yr0$ - 00$ - 00$ - 020$ - 02$ - 0
6-YR Maintaintenance -Chemical Facility Fire Suppression6 Yr0$ - 00$ - 00$ - 00$ - 01$ - 0
6-YR Maintaintenance - Hood and Duct6 Yr0$ - 01$ - 00$ - 00$ - 04$ - 0
TOTAL CLIN0002$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN000312-Yr Hydro Testing/Recharging
12-YR Hydrostatic Testing - ABC Extinguisher, 5 - 10 lb12 Yr25$ - 0150$ - 050$ - 0100$ - 0100$ - 0
12-YR Hydrostatic Testing - ABC Extinguisher, 20 lb12 Yr20$ - 040$ - 040$ - 020$ - 020$ - 0
12-YR Hydrostatic Testing - Specialized Agents12 Yr2$ - 02$ - 02$ - 02$ - 04$ - 0
12-YR Hydrostatic Testing - 125 lb. Dry Chemical12 Yr6$ - 00$ - 012$ - 00$ - 00$ - 0
12-YR Hydrostatic Testing - Halon 150lb.12 Yr35$ - 00$ - 00$ - 00$ - 00$ - 0
12-YR Hydrostatic Testing - NOVEC 123012 Yr0$ - 00$ - 00$ - 00$ - 00$ - 0
12-YR Hydrostatic Testing - Chemical Facility Fire Suppression12 Yr26$ - 00$ - 00$ - 00$ - 00$ - 0
12-YR Hydrostatic Testing - Hood and Duct12 Yr0$ - 04$ - 00$ - 00$ - 00$ - 0
TOTAL CLIN0003$ - 0$ - 0$ - 0$ - 0$ - 0
CLIN0004Emergency Services
Emergency ServicesAnnual1$ - 01$ - 01$ - 01$ - 01$ - 0
TOTAL CLIN0004$ - 0$ - 0$ - 0$ - 0$ - 0
Note:
TOTAL PER BASIC YEAR4994$ - 05206$ - 05217$ - 05228$ - 05095$ - 0

File details come from the government source that posted it. Updated .