Attachment 2 Final Drawings.pdf
PDF 10 MB Posted
- Attached to
- Upgrade HVAC for Bee Lab/Headhouse in Logan, UT
- Solicitation number
- 1232SA26Q0282
About this file
File Summary
This document is an architectural and engineering design package for an HVAC upgrade at the USDA Bee Lab/Headhouse Facility located at Utah State University in Logan, Utah. The project, identified as 2024-32, involves selective demolition and reconstruction of mechanical, electrical, and plumbing systems serving the Pollinating Insect-Biology Management, Systematics Research Unit.
The scope of work includes installation of new heating and cooling equipment, including two condensing boilers (B-1 and B-2), two end-suction pumps (P-1 and P-2), four inline circulators (P-3 and P-4), five unit heaters (UH-1 through UH-5), two ductless split system indoor units (AC-1 and AC-2), two condensing units (CU-1 and CU-2), one humidifier (HUM-1), one space distribution unit (SDU-1), two fan-powered terminal units (FPB-1 and FPB-2), and six exhaust fans (EF-G1 through EF-G6). An additive alternate (#1) provides for variable frequency drive-interlocked exhaust fans with backdraft dampers, bug guards, and factory-authorized startup. The project requires replacement of grooved fittings with welded connections throughout the heating hot water system, test and balance by a NEBB or AABC certified contractor, third-party commissioning by a licensed mechanical engineer, and comprehensive operation and maintenance documentation. The work must comply with current NEC, IBC, NFPA, and IFC codes, with all mechanical systems tied into the existing Johnson Controls Building Management System.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
H E
ID
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
R
S C
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
O N
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:3
A M
01.12.2026
CONDOC
AJL
K. RIGBY
G000
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
COVER SHEET
UPGRADE HVAC FOR USDA BEE LAB/HEADHOUSE
FACILITY
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
CONDOC
ajc ArchitectsARCHITECTURAL
SPECTRUM ENGINEERSMECH/PLUMB
SPECTRUM ENGINEERSELECTRICAL
703 EAST 1700 SOUTH
SALT LAKE CITY, UT 84105
PHONE: 801.466.8818
NAME: JUSTIN HEPPLER
EMAIL: JHEPPLER@AJCARCHITECTS.COM
324 STATE ST, SUITE 400
SALT LAKE CITY, UT 84111
PHONE: 801.328.5151
NAME: RYAN H BOOGAARD
EMAIL: RYAN.BOOGAARD@SPECENG.COM
324 STATE ST, SUITE 400
SALT LAKE CITY, UT 841111
PHONE: 801.328.5151
NAME: SPENCER L LITTLE
EMAIL: SPENCER.LITTLE@SPECENG.COM
USDAOWNER
800 BUCHANAN STREET
ALBANY, CA 94710
PHONE: 510.559.6340
NAME: PETER LANE
EMAIL: PETER.LANE@USDA.GOV
ADD ALTERNATES:
ADD ALT #1: (REFER TO SHEET MH101)
PROVIDE NEW VARIABLE FREQUENCY DRIVE INTELOCKED WITH CONTROLS SYSTEM.
FAN TO MODULATE BASED OFF OF COOLING AND VENTILATION NEEDS OF SPACE.
• PROVIDE WITH BACKDRAFT DAMPER, DISCONNECT SWITCH,
SUPPORT STAND AND BRACKETS, ISOLATOR, AND EXTERNAL RATED ENCLOSURE.
• PROVIDE WITH VARIABLE FREQUENCY DRIVE.
• PROVIDE WITH BUG GUARD ON FAN INLET.
• PROVIDE FACTORY AUTHORIZED STARTUP OF EQUIPMENT
INCLUDING STARTUP OF ANY FACTORY CONTROLS TO ENSURE
PROPER SEQUENCING AND/OR COMMUNICATION TO BMS.
MARK DATE DESCRIPTION
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/1
/2
:0
:2
P M
01.12.2026
CONDOC
AJL
K. RIGBY
G001
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
DRAWING INDEX AND
GENERAL NOTES
GENERAL NOTES:
1 THE GENERAL CONTRACTOR SHALL HEREAFTER BE REFERRED TO AS "GENERAL
CONTRACTOR" OR "GC". THE OWNER MAY HEREAFTER BE REFERRED TO AS
"OWNER".
2 THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REGARDLESS OF THE
LOCATION OF THE INFORMATION IN THE DOCUMENTS. THE GENERAL CONTRACTOR
SHALL UTILIZE THE COMPLETE & ENTIRE CONSTRUCTION DRAWINGS AND WRITTEN
SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE COMPLETE
CONSTRUCTION OF THIS PROJECT AND IS RESPONSIBLE TO COORDINATE ALL
DRAWINGS AND SPECIFICATIONS WITH ALL SUBCONTRACTORS REGARDLESS OF
LOCATION IN CONTRACT DOCUMENTS. ITEMS LISTED IN DRAWINGS MAY NOT BE
INCLUDED IN SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS MAY NOT BE
INCLUDED IN DRAWINGS.
3 UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING NOT IN
CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND INSTALLATION OF SAME
ARE PART OF THE CONTRACT AS DEFINED BY THE ENTIRE CONSTRUCTION
DOCUMENTS AND SPECIFICATIONS. THE GC SHALL PROVIDE AND INSTALL ALL
ACCESSORIES, COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK DEPICTED
OR SPECIFIED.
4 THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS
PRIOR TO BEGINNING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND
MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS. THE GC SHALL
ACCEPT PREMISES AS FOUND. OWNER WILL MAINTAIN THE EXISTING CONDITION OF
THE SITE AND EXISTING STRUCTURES AT THE TIME OF BIDDING.
5 DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT
INTENDED. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT ANY
SUCH DISCREPANCIES DURING BIDDING AND PRIOR TO COMMENCING WORK.
6 DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS: DO NOT SCALE DRAWINGS TO
DETERMINE ANY LOCATIONS. THE ARCHITECT SHALL BE NOTIFIED OF ANY
DISCREPANCY PRIOR TO CONTINUING WITH WORK. CHANGES IN THE WORK TO BE
DOCUMENTED IN WRITING AND APPROVED IN WRITING PRIOR TO BEING STARTED -
(IMPLEMENTED)
7 ALL PLAN DIMENSIONS ARE FROM GRIDLINE OR FACE OF STUD OR FACE OF BLOCK
UNLESS OTHERWISE INDICATED. SEE SECTION ON "DIMENSIONING" THIS SHEET.
8 THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ALL CONDITIONS REQUIRING
COORDINATION/ CHANGES WITH THE CONTRACT DOCUMENTS. COORDINATION /
APPROVAL SHALL TAKE PLACE BEFORE THE WORK BEGINS. ALL CHANGES TO THE
CONTRACT COST SHALL BE APPROVED THROUGH A CHANGE ORDER.
9 DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER
SMALL SCALE DRAWINGS.
10 THE ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR CONFORMANCE
WITH DESIGN CONCEPT OF THE PROJECT. THE ARCHITECT'S REVIEW OF A SEPARATE
ITEM SHALL NOT INDICATE APPROVAL OF AN ASSEMBLY IN WHICH THE ITEM
FUNCTIONS. THE ARCHITECT WILL NOT REVIEW SHOP DRAWINGS UNTIL THE GC HAS
REVIEWED AND STAMPED THE SHOP DRAWING/SUBMITTAL. THE GC IS RESPONSIBLE
FOR FIELD VERIFYING ALL DIMENSIONS SHOWN ON THE SHOP DRAWINGS. THE
ARCHITECT'S REVIEW OF THE SHOP DRAWINGS SHALL NOT OVERRIDE THE
CONDITIONS DESCRIBED IN THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY
NOTED OTHERWISE BY THE ARCHITECT. WORK SHALL NOT PROCEED WITHOUT
RETURNED REVIEWED SUBMITTALS.
11 FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S STANDARD
DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN ACCORDANCE WITH THE
PROJECT SPECIFICATIONS.
12 ALL WORK, MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE
CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES
HAVING JURISDICTION AT THE PROJECT LOCATION. THE GENERAL CONTRACTOR
MUST COMPLY WITH THE CONTRACTOR REGISTRATION REQUIREMENTS OF ALL
GOVERNING AUTHORITIES.
13 THE GENERAL CONTRACTOR SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING
AUTHORITIES AND UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING
INSPECTION.
14 THE GENERAL CONTRACTOR SHALL MAINTAIN ALL REQUIRED EXITS AND FIRE LANES IN
WORKING ORDER.
15 A BUILDING PERMIT PROVIDED BY USU IS REQUIRED. ALL PERMITS AND CONNECTION
FEES SHALL BE SECURED BY THE GENERAL CONTRACTOR AND REIMBURSED THROUGH
THE OWNER.
16 MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO
THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. SEE
CODE SUMMARY, SHEET G005.
17 THE GENERAL CONTRACTOR SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND
LIABLE FOR PUBLIC AND EMPLOYEE PROTECTION AS NECESSARY AND AS REQUIRED
BY THE CODES, INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS.
ALL WORK SHALL CONFORM TO THE ORDINANCES AND REGULATIONS OF
GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT.
18 THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES FOR DUST
AND NOISE CONTROL, AND ALL REQUIRED ENVIRONMENTAL PROTECTION WHERE
WORK JOINS EXISTING CONDITIONS.
19 ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A
CLEAN (BROOM) CONDITION DAILY.
20 APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE
GENERAL CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD CONDITION, ONE
COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS, ON
THE PREMISES AT ALL TIMES. THESE ARE TO BE KEPT UNDER THE CARE OF THE JOB
SUPERINTENDENT.
21 THE GENERAL CONTRACTOR IS TO ASSURE THAT NO REBAR OR REINFORCEMENT IS
PRESENT PRIOR TO CORE DRILLING OR PLACING BOLTS OR ANY OTHER ITEM WHICH
COULD DISTURB THE STRUCTURAL SLAB OR FOUNDATION WALLS.
22 PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE
REQUIRED.
23 PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER AND DRYWALL
SURFACES WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL, UNLESS NOTED
OTHERWISE.
24 ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH
APPROPRIATE SEALANT MATERIAL.
25 THE GC SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT PADS & BASES WITH
EQUIPMENT MANUFACTURERS & SHALL VERIFY ALL SIZES AND LOCATIONS OF DUCT
OPENINGS ON ROOF AND INTERIOR SHAFTS.
SCOPE OF WORK:
NEW HVAC SYSTEM AT EXISTING RESEARCH LAB BUILDING. UTAH STATE UNIVERSITY
CAMPUS LOGAN UTAH. SELECTRIVE DEMOLITION AND RECONSTRUCTION AS
INDICATED. ELECTRICAL POWER UPGRADES AS INDICATED.
DRAWING INDEX:
GENERAL
G000 COVER SHEET
G001 DRAWING INDEX AND GENERAL NOTES
G002 ABBREVIATIONS, DIMENSIONING LEGEND, SYMBOLS
G003 VICINITY MAP, LOCATION MAP
G005 BUILDING CODE SUMMARY, CODE PLAN
ARCHITECTURAL
AD101 DEMOLITION PLAN
A101 ANNOTATED FLOOR PLAN
A131 CEILING PLAN
A140 ROOF PLAN
A500 DETAILS
MECHANICAL
ME001 MECHANICAL COVER SHEET
ME501 MECHANICAL DETAILS
ME601 MECHANICAL SCHEDULES
ME602 MECHANICAL SCHEDULES
MD101 LEVEL 1 MECHANICAL DEMO PLAN
MD102 ROOF MECHANICAL DEMO PLAN
MH101 LEVEL 1 MECHANICAL PLAN
MH102 ROOF MECHANICAL PLAN
MH401 ENLARGED MECHANICAL PLANS
ELECTRICAL
EE001 ELECTRICAL COVER SHEET
EE504 ELEC-MECH DETAILS
ED101 LEVEL 1 ELECTRICAL DEMOLITION PLAN
EP101 LEVEL 1 POWER PLAN
EP102 ROOF POWER PLAN
EP605 EQUIPMENT SCHEDULE
EP616 PANEL SCHEDULES
EP617 PANEL SCHEDULES
ADD ALTERNATES:
ADD ALT #1: PROVIDE NEW VARIABLE SPEED FANS. REUSE EXISTING OPENINGS WHERE
POSSIBLE.
CL
DRAWING NUMBER
DRAWING NAME
DRAWING SCALE
01 WINDOW/CURTAIN WALL DESIGNATION. SEE WINDOW SCHEDULE.
A101
A9
A
A9
A
DATUM TAGREVISION CLOUD & TAG
REVISION CLOUD
AROUND AREA OF
CHANGE
DELTA SYMBOL
& REVISION
NUMBER
? KEYNOTE.
GRID HEAD
n
GLAZING DESIGNATION.
GLAZING MODIFIER
201.1 DOOR DESIGNATION. SEE DOOR SCHEDULE
F1 WALL, FLOOR, CEILING, ROOF TYPE DESIGNATION. SEE APPROPRIATE
TYPE SHEETS.
WALL, FLOOR, BASE, CEILING FINISH TAG. THIS SYMBOL WHEN
ATTACHED TO A WALL SHALL INDICATE THIS FINISH FOR ENTIRE
LENGTH OF WALL FROM ONE INTERSECTION TO THE NEXT AND NOT
BE TERMINATED BY WINDOWS OR DOORS UNO.
ROOM NAME
ROOM NAME TAG
NW
SW
EWWWFF BF
Ø
CENTER LINE
NUMBER
DEGREE
AND
AT
WORK POINT OR ELEV. BENCH MARK
DIAMETER OR ROUND
NORTH ARROW
DETAIL TAGS
DETAIL NUMBER
PAGE WHERE FOUND
DETAIL CUT LINE
DETAILED AREA
WALL SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
BUILDING SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
DRAWING TITLE
ELEVATION TAGS
PAGE
VIEW
ROOM FINISH TAG
FLOOR FINISH
CORRESPONDING
WALL FINISHES
BASE FINISH
MISCELLANEOUS KEYED NOTE SYMBOLS
ROOM NAME
ROOM NUMBER
ELEVATION DATUM
INDICATES ITEM OR
FLOOR LEVEL BEING
REFERENCED
A1 A101
NAME
ELEVATION
AA
A1 A101
A1 A101
A1 A101
1/8" = 1'-0", DWG REF: R101
DRAWING NAME
DRAWING REF
METAL
EARTH
CONCRETE
CONCRETE
MASONRY UNIT
FINISHED WOOD
MEMBER
PLYWOOD
BATT INSULATION
GYP. BOARD
CONTINUOUS WOOD
MEMBER
WOOD BLOCKING
OR SHIM
PLASTER OR STUCCO RIGID INSULATION
MINERAL WOOL
INSULATION
GRAVEL
MDF
METAL OR WOOD STUD FRAMED WALL
• WALL TYPE DESIGNATES WIDTH OF WALL
• WIDTH OF WALL DIMENSIONED ONLY AT
1/4"=1' OR LARGER SCALE
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
METAL OR WOOD STUD FRAMED WALL W/
MASONRY OR STONE VENEER
• WIDTH OF WALL DIMENSIONED FROM
FACE OF MASONRY.
• WIDTH OF MASONRY WALL DIMENSIONED
FROM FACE OF STUD.
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
MASONRY WALL
• WIDTH OF WALL DIMENSIONED TO
NOMINAL SIZE.
• DOORS DIMENSIONED TO CENTERLINE OF
NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT MASONRY OPENING.
CONCRETE WALL
• ACTUAL WIDTH OF WALL DIMENSIONED
• DOORS DIMENSIONED TO CENTERLINE OF
NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
NEW CONSTRUCTION SHOWN HATCHED PER MATERIAL W/ THICKER LINE.
ALL EXISTING COMPONENTS SHOWN THIN LINE SOLID, SOLID GRAY HATCH.
ALL EXISTING COMPONENTS SHOWN THIN LINE SOLID, SOLID GRAY HATCH.
ALL COMPONENTS TO BE DEMOLISHED ARE SHOWN DASHED, THICK LINE.
EXISTING
METAL OR WOOD STUD FRAMED WALL.
• WIDTH OF WALL DIMENSIONED TO
FINISHED FACE.
• DOORS DIMENSIONED TO NOMINAL
DOOR SIZE EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
METAL OR WOOD STUD FRAMED WALL W/
MASONRY OR STONE VENEER
• WIDTH OF WALL DIMENSIONED FROM
FINISHED FACE TO OVERALL NOMINAL
WIDTH.
• DOORS DIMENSIONED TO NOMINAL
DOOR SIZE EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
MASONRY WALL (TO REMAIN)
• WIDTH OF WALL DIMENSIONED TO
NOMINAL SIZE.
• DOORS DIMENSIONED TO NOMINAL
DOOR SIZE EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
CONCRETE WALL (TO REMAIN)
• NOMINAL WIDTH OF WALL
DIMENSIONED.
• DOORS DIMENSIONED TO NOMINAL
DOOR SIZE EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE.
ALL NEW CONSTRUCTION IS SHOWN HATCHED & SHADED AS ILLUSTRATED BELOW.
ALL NEW CONSTRUCTION IS FULLY NOTED AS SHOWN BELOW.
ALL WORK IS NEW UNLESS LABELED "EXISTING"
ALL EXISTING CONSTRUCTION IS SHOWN WITHOUT HATCH AS ILLUSTRATED BELOW.
ALL EXISTING CONSTRUCTION IS LABELED "EXISTING" BY KEYNOTE OR OTHERWISE.
ALL DIMENSIONS TO EXISTING ARE APPROXIMATE ONLY AND ARE TO BE FIELD
VERIFIED BY THE CONTRACTOR.
(DEMOLISH
EXISTING)
(EXISTING TO
REMAIN)
DOOR TAG
WALL TYPE
WALL TYPE
WALL TYPE
WALL TYPE
WINDOW TYPE
WINDOW TYPE
WINDOW TYPE
WALL TYPE
DIMENSIONING LEGEND
NEW CONSTRUCTION AT EXISTING
EXISTING CONDITIONS
DEMOLITION AT EXISTING
1 1
1 1
1 1
1 1
4M
6A
X
TO
P
4'-0"
/4
4'-0"
4'-0"
4'-0"
4'-0"
3'-3 1/2" ±
/8
/8
/8
4'-0" ±
4'-0" ±
4'-0" ±
RIGHT SIDE
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:3
A M
01.12.2026
CONDOC
AJL
K. RIGBY
G002
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
ABBREVIATIONS,
DIMENSIONING
LEGEND, SYMBOLS
SECTION MATERIALS LEGEND
SYMBOLS
ABBREV ABBREVIATION (S)
ABB ABBREVIATION (S)
A.F.F. ABOVE FINISHED FLOOR
AD ACCESS DOOR
ACOUS ACOUSTICAL
A/C AIR CONDITIONING
ALUM ALUMINUM
AB ANCHOR BOLT
APPR APPROVED
AC ASPHALT CONCRETE
BM BEAM
BLK BLOCK
BD BOARD
BOT BOTTOM
B.O. BOTTOM OF
B.O.B. BOTTOM OF BEAM
BLDG BUILDING
CLG CEILING
CH CEILING HEIGHT
CEM CEMENT
C/C CENTER TO CENTER
CER CERAMIC
CLR CLEAR
CLOS CLOSET
COL COLUMN
COMPO COMPOSITION
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONN CONNECTION
CONT CONTINUOUS
CORD COORDINATE
CORR CORRIDOR
CSK COUNTERSINK
DEL DELETE
DEMO DEMOLITION
DET DETAIL
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DR DOOR
DO DOOR OPENING
DBL DOUBLE
DF DOUGLAS FIR
DN DOWN
DS DOWNSPOUT
DWG DRAWING
DF DRINKING FOUNTAIN
EA EACH
EWC ELECTRIC WATER COOLER
ELEC ELECTRICAL
ELEV OR EL ELEVATION
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EJ EXPANSION JOINT
EXT EXTERIOR
FOC FACE OF CONCRETE
FOS FACE OF STUD
FOW FACE OF WALL
FT FEET
FRP FIBER REINFORCED PLASTIC
FIN FINISH
FF FINISH FLOOR
FO FINISHED OPENING
FHC FIRE HOSE CABINET
FLR FLOOR
FD FLOOR DRAIN
FS FLOOR SINK
FDN FOUNDATION
FH FULL HEIGHT
FS FULL SIZE
FSD FULL SIZE DETAIL
GALV OR
GV
GALVANIZED
GA GAUGE
GC GENERAL CONTRACTOR
GL GLASS
GFRC GLASS FIBER REINFORCED
CONCRETE
GR GRADE
GYP. BD. GYPSUM BOARD
HDWD HARDWOOD
H HIGH
HP HIGH POINT
HM HOLLOW METAL
HORIZ HORIZONTAL
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
LAV LAVATORY
LEV LEVEL
LTWT LIGHT WEIGHT
LTG LIGHTING
ABBREVIATIONS
MAINT MAINTENANCE
MFG MANUFACTURER
MO MASONRY OPENING
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MB MECHANICAL BOLT
MET METAL
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MULL MULLION
(N) NEW
NR NON-RATED
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. NUMBER
OFF OFFICE
OC ON CENTER
OPN'G OPENING
OCC OPERATOR CONTROL CENTER
OPP OPPOSITE
OH OPPOSITE HAND
OD OUTSIDE DIAMETER
OF OVERFLOW
OFI OWNER FURNISH ITEM
OFOI OWNER FURNISHED OWNER
INSTALLED
PR PAIR
PLAS PLASTIC
PL PLATE
PLWD PLYWOOD
PC PORTLAND CEMENT
PREP PREPARATION
PT PRESSURE TREATED
PTDF PRESSURE TREATED DOUGLAS
FIR
PROJ PROJECTION
QT QUARRY TILE
REF FREFERENCE
R OR RAD RADIUS
REDW'D REDWOOD
REFL REFLECTED
RCP REFLECTED CEILING PLAN
REINF REINFORCE
REQ'D REQUIRED
RES RESILIENT
RR RESTROOM(S)
R RISER
RD ROOF DRAIN
RTU ROOF TOP UNIT
RM ROOM
R.O. ROUGH OPENING
SECT SECTION
SHT SHEET
SIM SIMILAR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STG STORAGE
STRUCT STRUCTURAL
SIMUL SUMULATED
SUSP SUSPENDED
SYM SYMMETRICAL
TEL TELEPHONE
TEMP TEMPERED
THK THICK
T&G TONGUE & GROOVE
TBC TOP BACK OF CURB
T.O. TOP OF
T.O.C. TOP OF CONCRETE OR CURB
T.O.F TOP OF FOOTING
T.O.P. TOP OF PARAPET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TDC TRAFFIC DECK COVERING
T TREAD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
V.I.F. VERIFY IN FIELD
VER VERTICAL
WC WATER CLOSET
WL WATER LEVEL
WP WATERPROOFING
W WIDE
W/ WITH
WD WOOD
WP WORKING POINT
WI WROUGHT IRON
E 1400 N
E
PROJECT LOCATION
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
G003
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:3
A M
01.12.2026
CONDOC
AJL
K. RIGBY
G003
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
VICINITY MAP,
LOCATION MAP
NTS
VICINTY MAP
GENERAL NOTES:
nNTS
LOCATION MAP
n
A DB C
-2
TOTAL TRAVEL = 81'
COMMON PATH = 33'
TOTAL TRAVEL = 110'
COMMON PATH = 21'
OFFICE
VEST
OFFICE
JAN
TOILET
TOILET
OFFICE
OFFICE
CORR
TELE
MECHANICAL
ELECTRICAL
PATH LAB
LAB
COLD ROOM
CORR
MOLECULAR
LAB
LAB ROOM
BREAK ROOM
LAB WORKROOM
STORAGEOBSERVATION
GREENHOUSEGREENHOUSE
CORR
CORR
CORR
CORR
CORR
LAB
MOLECULAR
LAB
FREEZER/INCUBATOR
ROOM
FE
F E
FE
EXIT
180 22
EXIT
180 22
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
FE
EXIT
180 22
CODE LEGEND
REFERENCES:
· UL FIRE RESISTANCE DIRECTORY; CURRENT EDITION.
· NFPA 101 LIFE SAFETY CODE
· ALL GOVERNING LOCAL AND REGIONAL BUILDING CODES
FIRESTOP SYSTEM INSTALLATION MUST MEET REQUIREMENTS OF ASTM E1966 (UL 2079)
TESTED ASSEMBLIES THAT PROVIDE A FIRE RATING EQUAL TO THAT OF THE
SURROUNDING CONSTRUCTION.
UL NOTES
EXIT TRAVEL DISTANCE
EXISTING FIRE EXTINGUISHER
DOOR EXIT CAPACITY / REQUIRED EXIT CAPACITY
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:4
A M
01.12.2026
CONDOC
AJL/MT
K. RIGBY
G005
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
BUILDING CODE
SUMMARY, CODE
PLAN
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n 1/8" = 1'-0" , A2
CODE PLAN
GENERAL NOTES
NFPA 101 2024
NFPA 13 2022
NFPA 1 2024
NFPA 220 2024
NFPA 5000 2024
INTERNATIONAL BUILDING CODE (IBC) 2021
INTERNATIONAL EXISTING BUILDING CODE 2021
ICC ANSI A117.1 2017
OCCUPANCY CLASSIFICATION – NFPA 101-3.3.198.3 & IBC CHAPTER 3
‘B’ - BUSINESS
TYPE OF CONSTRUCTION – NFPA 220 4.4.2 & IBC CHAPTER 6
TYPE III (200) / TYPE III - B
AUTOMATIC SPRINKLER SYSTEM – NFPA 13 & IBC SECTION 903.2.6
N/A – NOT SPRINKLED
BUILDING CODE SUMMARY
GROSS BUILDING AREA:
HEADHOUSE 5,913 S.F.
GREENHOUSE 1 2,491 S.F.
GREENHOUSE 2 2,491 S.F.
ALLOWABLE BUILDING HEIGHT – NFPA 5000 TABLE 7.4.1 & IBC CHAPTER 5, TABLE 504.3
ALLOWED: 55 FEET
ACTUAL: 16 FEET
ALLOWABLE STORIES ABOVE GRADE PLANE – NFPA 5000 TABLE 7.4.1 & IBC CHAPTER 5,
TABLE 504.4
ALLOWED: 4 / 3 STORIES
ACTUAL: 1 STORY
ALLOWABLE BUILDING AREA – NFPA 5000 TABLE 7.4.1 & IBC CHAPTER 5, TABLE 506.2
ALLOWED: 19,000 S.F.
ACTUAL: 10,895 S.F.
BUILDING AREA SUMMARY
FIRE RESISTIVE REQUIREMENTS – NFPA 5000 TABLE 7.2.1.1 & IBC CHAPTER 6, TABLE 601
STRUCTURAL FRAME
EXTERIOR 2.0 HOURS
INTERIOR 0.0 HOURS
EXTERIOR NONBEARING WALLS 0.0 HOURS
INTERIOR NONBEARING WALLS 0.0 HOURS
FLOOR (INCLUDING SUPPORTING BEAM AND JOISTS) 0.0 HOURS
ROOF (INCLUDING SUPPORTING BEAM AND JOISTS) 0.0 HOURS
CORRIDORS – NFPA 101, 38.3.6.1(2) & IBC TABLE 1020.1;
1-HR RATED
TRAVEL DISTANCE – NFPA 101, 38.2.6.2 & IBC SECTION 1017.2
200 FEET
COMMON PATH OF EGRESS TRAVEL – NFPA 101, 38.2.5.2.3 & IBC TABLE 1006.2.1
75 FEET
EXIT SEPARATION – NFPA 101, 7.5.1.3.2 & IBC SECTION 1007.1.1
SEPARATION OF EXITS SHALL BE 1/2 THE LENGTH OF THE MAXIMUM DIAGONAL
DIMENSION.
OCCUPANCY LOADS – IBC TABLE 1004.5
AGRICULTURE 300 GROSS
BUSINESS OFFICES 150 GROSS
OCCUPANTS
OFFICES 40
GREENHOUSE 4
TOTAL OCCUPANTS 44
NUMBER OF REQUIRED EXITS – NFPA 101, 38.2.4.1(2) & IBC TABLE 1006.2.1
REQUIRED: 2
PROVIDED: 3
MINIMUM CORRIDOR WIDTHS – NFPA 101, 39.2.3.2 & IBC TABLE 1020.2
REQUIRED: 44 INCHES
PROVIDED: 72 INCHES
DEAD END CORRIDORS – NFPA 5000, 28.2.5.3.2 & IBC SECTION 1020.4
20 FEET
PORTABLE FIRE EXTINGUISHERS: NFPA 1, 13.6.1.2 & IBC SECTION 906
MAXIMUM DISTANCE OF TRAVEL TO EXTINGUISHER 75 FEET
LIFE SAFETY SUMMARY
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
A DB C
-2
OFFICE
OFFICE
TOILET
TOILET
08 OFFICE
PATH LAB
ELECTRICAL
MECHANICAL
FREEZER/INCUBATOR
ROOM
MOLECULAR LAB
MOLECULAR LAB
LAB ROOM
BREAK ROOM
LAB WORKROOM
VEST
OFFICE
LAB
LAB
COLD ROOM
OBSERVATION
STORAGE
CORR
CORR
CORR
TELE
CORR
CORR
JAN
31'-0" 18'-0" 32'-0"
GREENHOUSE
GREENHOUSE
CORR
CORR
2 1
1 1
2 2
44 2 2
5 5
9 9
9 9
9 9
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:3
A M
01.12.2026
CONDOC
AJL
K. RIGBY
AD101
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
DEMOLITION PLAN
ALL ITEMS SHOWN THIS PAGE ARE EXISTING TO REMAIN UNLESS NOTED OTHERWISE
GRAPHICALLY OR BY KEYED NOTE. EXTENTS OF THIS SELECTIVE DEMOLITION PACKAGE
ARE THE BUILDING'S ENVELOPE AND ANY SMALL PENETRATIONS TO BE SEALED TO
MAINTAIN AN AIRTIGHT ENVELOPE. CONTRACTOR TO PROVIDE ANY TEMPORARY
CONSTRUCTION TO MAINTAIN ENVELOPE INTEGRITY.
STANDARD GRAPHIC REPRESENTATIONS OF WALLS, DOORS, PLUMBING FIXTURES &
TOILET ACCESSORIES INDEPENDENTLY REFERENCE DEMO OR EXISTING TO REMAIN
CONDITIONS WITH OR WITHOUT AN ATTACHED KEYED NOTE. PROVIDE DEMO OF ALL
ITEMS SHOWN DASHED. (SEE PRECEDING NOTE).
SEE MECHANICAL (MD) DEMO & ELECTRICAL (ED) DEMO SHEETS AND
SPECIFICATIONS FOR ADDITIONAL DEMOLITION OR EXISTING CONDITIONS
INFORMATION. WHERE PLUMBING, MECHANICAL OR ELECTRICAL ITEMS ARE SHOWN
DEMO’D ON THIS PAGE. THE INFORMATION IS SUPPLIED AS A SUPPLEMENT TO THE MD
SHEETS AND ED SHEETS. THE EXTENT OF THE DEMOLITION IS AS PER REQUIRED BY THE
SPECIFICATIONS, MD SHEETS AND ED SHEETS.
DISPOSE OF ALL MATERIALS MARKED AS "REMOVE" OR "DEMO" RECYCLE REMOVED
MATERIALS WHENEVER PRACTICAL.” CONDITIONS MARKED "SALVAGED" ARE REUSED
DURING NEW CONSTRUCTION AND SHOULD BE PROTECT UNTIL REINSTALLATION.
COORDINATE WITH ARCHITECT ANY DISCREPENCIES.
REMOVE: UNLESS ITEMS ARE OTHERWISE INDICATED TO BE REINSTALLED OR
SALAVAGED, REMOVE AND DISPOSE BY RECYCLING TO GREATEST EXTENT POSSIBLE
OR IS PRACTICAL
REMOVE AND REINSTALL: REMOVE ITEMS INDICATED; CLEAN, SERVICE AND
OTHERWISE PERPARE FOR SERVICE; REINSTALL IN THE SAME LOCATION (OR IN THE
LOCATION INDICATED).
REMOVE AND RECYCLE: REMOVE AND RECYCLE TO THE GRATEST EXTENT PRACTICAL
OF ITEMS INDICATED. ALL DEMOLISHED OR REMOVED ITEMS AND MATERIALS SHALL
BE CONSIDERED SCRAP, EXCEPT FOR THOSE INDICATED TO REMAIN, THOSE
INDICATED TO BE REINSTALLED, AND THOSE INDICATED TO BE SALVAGED.
EXISTING TO REMAIN: CONSTRUCTION OR ITEMS INDICATED TO REMAIN SHALL BE
PROTECTED AGAINST DAMAGE DURING DEMOLITION OPERATIONS. WHERE
PRACTICABLE, AND WITH THE ARCHITECT'S PERMISSION, THE CONTRACTOR MAY
ELECT TO REMOVE ITEMS TO A SUITABLE STORAGE LOCATION DURING DEMOLITION
AND THEN PROPERLY CLEAN AND REINSTALL THE ITEMS.
KEYED NOTES:
1 EXISTING WALL TO BE PROTECTED DURING CONSTRUCTION AND REMAIN.
2 EXISTING DOOR TO BE PROTECTED DURING CONSTRUCTION AND REMAIN.
3 EXISTING STOREFRONT SYSTEM TO BE PROTECTED DURING CONSTRUCTION AND
REMAIN.
4 EXISTING GREENHOUSE WALL TO REMAIN, PROTECT DURING ALL PHASES OF
CONSTRUCTION.
5 EXISTING EXHAUST FAN TO BE REMOVED, SEE MECHANICAL DRAWINGS, ADD ALT #1
6 EXISTING EVAPORATIVE COOLING MEDIA TO BE REMOVED, SEE MECHANICAL
DRAWINGS, ADD ALT #1
7 EXISTING HUMIDIFIER TO BE REMOVED, PATCH AND REPAIR SURROUNDING AREA AS
NEEDED , SEE MECHANICAL DRAWINGS.
8 EXISTING VAV BOX TO BE REMOVED, REMOVE EXISTING CEILING SYSTEM AS NEEDED
FOR REMOVAL AND REPLACEMENT SEE MECHANICAL DRAWINGS.
9 PROVIDE SHEET METAL INFILL PANEL AT ALL LOCATIONS WHERE EXISTING FANS ARE
TO BE REMOVED. PROVIDE FULL BEAD OF SEALANT AT PERIMETER OF PANEL AND
ATTACH TO EXISTING WINDOW FRAME WITH SELF TAPPING SCREWS WITH NEOPRENE
WASHERS . PROVIDE CONT SEALANT AT ALL PENETRATIONS THAT ARE TO BE MADE
THRU PANEL.
DEMOLITION DEFINITIONS
DEMOLITION NOTES
GENERAL NOTES:
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n1/8" = 1'-0" , DEMOLITION PLAN
OFFICE
OFFICE
TOILET
TOILET
08 OFFICE
PATH LAB
ELECTRICAL
MECHANICAL
FREEZER/INCUBATOR
ROOM
MOLECULAR LAB
MOLECULAR LAB
LAB ROOM
BREAK ROOM
LAB WORKROOM
VEST
OFFICE
LAB
LAB
COLD ROOM
OBSERVATION
STORAGE
CORR
CORR
CORR
TELE
CORR
CORR
JAN
-2
31'-0" 18'-0" 32'-0"
GREENHOUSE
GREENHOUSE
CORR
CORR
2 1
1 1
2 2
44 2 2
ADD ALT #1:
PROVIDE NEW
VARIABLE SPEED
FANS. REUSE
EXISTING OPENINGS
WHERE POSSIBLE.
ADD ALT #1:
PROVIDE NEW
VARIABLE SPEED
FANS. REUSE
EXISTING OPENINGS
WHERE POSSIBLE.
6 6
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
DUE TO THE ABSENCE OF ACCURATE RECORD DRAWINGS FOR THE ORIGINAL BUILDING
DESIGN, MANY DESIGN DECISIONS MADE FOR THIS PROJECT HAVE BEEN BASED ON
ASSUMPTIONS AND VISUAL INSPECTIONS OF EXISTING SITE CONDITIONS BY THE DESIGN
TEAM - CONSEQUENTLY, DISPARITIES BETWEEN ASSUMED AND ACTUAL EXISTING
CONDITIONS MAY ARISE.
IT IS IMPERATIVE THAT THE CONTRACTOR CAREFULLY VERIFIES ALL EXISTING CONDITIONS
AND COORDINATES THEM WITH THE NEW WORK .
IF THE EXISTING CONDITIONS ARE FOUND TO DEVIATE FROM THE ASSUMPTIONS MADE IN
THE DESIGN, RESULTING IN CONFLICTS, THE CONTRACTOR IS REQUIRED TO COORDINATE
THE VERIFIED SITE CONDITIONS AS WELL AS THE RESULTING CONFLICTS, WITH THE
ARCHITECT (FOR RESOLUTION), BEFORE PROCEEDING WITH THE INSTALLATION OF NEW
WORK.
EXISTING BUILDING NOTE
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:2
A M
01.12.2026
CONDOC
AJL
K. RIGBY
A101
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
ANNOTATED FLOOR
PLAN
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16'
1/8" = 1'-0" A2
ANNOTATED FLOOR PLAN
n
GENERAL NOTES:
KEYED NOTES:
1 EXISTING WALL TO BE PROTECTED DURING CONSTRUCTION AND REMAIN.
2 EXISTING DOOR TO BE PROTECTED DURING CONSTRUCTION AND REMAIN.
3 EXISTING STOREFRONT SYSTEM TO BE PROTECTED DURING CONSTRUCTION AND
REMAIN.
4 EXISTING GREENHOUSE WALL TO REMAIN, PROTECT DURING ALL PHASES OF
CONSTRUCTION.
5 NEW MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS.
6 PROVIDE SHEET METAL INFILL PANEL AT ALL LOCATIONS WHERE EXISTING FANS ARE
TO BE REMOVED. PROVIDE FULL BEAD OF SEALANT AT PERIMETER OF PANEL AND
ATTACH TO EXISTING WINDOW FRAME WITH SELF TAPPING SCREWS WITH NEOPRENE
WASHERS . PROVIDE CONT SEALANT AT ALL PENETRATIONS THAT ARE TO BE MADE
THRU PANEL.
OFFICE
VEST
OFFICE
TOILET
JAN
18 TOILET
OFFICE
OFFICE
PATH LAB
ELECTRICAL
CORR
CORR
MECHANICAL
CORR
FREEZER/INCUBATOR
ROOM
MOLECULAR LAB
COLD ROOM
BREAK ROOM
LAB
LAB
LAB WORKROOM
LAB ROOM
25MOLECULAR LAB
CORR
OBSERVATION
STORAGE
-2
31'-0" 18'-0" 32'-0"
GREENHOUSE
GREENHOUSE
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
DUE TO THE ABSENCE OF ACCURATE RECORD DRAWINGS FOR THE ORIGINAL BUILDING
DESIGN, MANY DESIGN DECISIONS MADE FOR THIS PROJECT HAVE BEEN BASED ON
ASSUMPTIONS AND VISUAL INSPECTIONS OF EXISTING SITE CONDITIONS BY THE DESIGN
TEAM - CONSEQUENTLY, DISPARITIES BETWEEN ASSUMED AND ACTUAL EXISTING
CONDITIONS MAY ARISE.
IT IS IMPERATIVE THAT THE CONTRACTOR CAREFULLY VERIFIES ALL EXISTING CONDITIONS
AND COORDINATES THEM WITH THE NEW WORK .
IF THE EXISTING CONDITIONS ARE FOUND TO DEVIATE FROM THE ASSUMPTIONS MADE IN
THE DESIGN, RESULTING IN CONFLICTS, THE CONTRACTOR IS REQUIRED TO COORDINATE
THE VERIFIED SITE CONDITIONS AS WELL AS THE RESULTING CONFLICTS, WITH THE
ARCHITECT (FOR RESOLUTION), BEFORE PROCEEDING WITH THE INSTALLATION OF NEW
WORK.
EXISTING BUILDING NOTE
SURFACE MOUNTED OR LAY-IN CEILING
FLUORESCENT FIXTURE. SEE ELECTRICAL
PLAN FOR SIZE AND TYPE.
SUPPLY, RETURN & EXHAUST
DIFFUSERS/GRILLES. SEE MECHANICAL.
RETURN/
EXHAUST
SUPPLY
THIS IS A REFLECTED CEILING PLAN AND IS NOT TO BE INTENDED TO BE A LIGHTING
PLAN. NO WALL MOUNTED LIGHTING FIXTURES OR OTHER WALL MOUNTED
APPURTENANCES ARE SHOWN. SEE THE LIGHTING PLAN FOR ALL LIGHTING AND EGRESS
SIGNS, SIZE AND TYPES OF ELECTRICAL FIXTURES ETC. SEE MECHANICAL PLANS FOR ALL
CEILING MOUNTED DIFFUSERS/GRILLES ETC.
SYMBOL LEGEND
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:2
A M
01.12.2026
CONDOC
AJL
K. RIGBY
A131
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
CEILING PLAN
1/8" = 1'-0" , REFLECTED CEILING PLAN
GENERAL NOTES AND LEGENDS:
0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n
KEYED NOTES:
1 EXISTING LAY-IN PANEL CEILING SYSTEM TO BE REMOVED AS NEEDED TO REMOVE
EXISTING MECHANICAL UNIT AND REPLACE. CEILING SYSTEM TO BE REPLACED IN
KIND. COORDINATE WITH MECHANICAL DWGS
2 EXISTING SUSPENDED ACOUSTICAL PANEL CEILING SYSTEM. TO REMAIN, PROTECT.
3 EXISTING GYP BOARD CEILING TO REMAIN.
4 EXISTING GREENHOUSE WALL TO REMAIN, PROTECT DURING ALL PHASES OF
CONSTRUCTION.
5 EXISTING GREENHOUSE ROOF/CEILING, PROTECT DURING ALL PHASES OF
DEMOLITION AND CONSTRUCTION.
6 CEILING MOUNTED MECHANICAL UNIT.
CEILING LEGEND:
SEE SHEET G001 FOR DRAWING INDEX.
SEE SHEET G001 FOR GENERAL NOTES AND SHEET G002 FOR ABBREVIATIONS.
DO NOT SCALE DRAWINGS.
CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS
BEFORE BEGINNING WORK, AND SHALL REPORT TO THE ARCHITECT ANY ERRORS,
INCONSISTENCIES OR OMISSIONS BEFORE BEGINNING WORK. SEE GENERAL NOTES AND
SPECIFICATIONS.
A DB C
-2
31'-0" 18'-0" 32'-0"
3 3
5 5
DUE TO THE ABSENCE OF ACCURATE RECORD DRAWINGS FOR THE ORIGINAL BUILDING
DESIGN, MANY DESIGN DECISIONS MADE FOR THIS PROJECT HAVE BEEN BASED ON
ASSUMPTIONS AND VISUAL INSPECTIONS OF EXISTING SITE CONDITIONS BY THE DESIGN
TEAM - CONSEQUENTLY, DISPARITIES BETWEEN ASSUMED AND ACTUAL EXISTING
CONDITIONS MAY ARISE.
IT IS IMPERATIVE THAT THE CONTRACTOR CAREFULLY VERIFIES ALL EXISTING CONDITIONS
AND COORDINATES THEM WITH THE NEW WORK .
IF THE EXISTING CONDITIONS ARE FOUND TO DEVIATE FROM THE ASSUMPTIONS MADE IN
THE DESIGN, RESULTING IN CONFLICTS, THE CONTRACTOR IS REQUIRED TO COORDINATE
THE VERIFIED SITE CONDITIONS AS WELL AS THE RESULTING CONFLICTS, WITH THE
ARCHITECT (FOR RESOLUTION), BEFORE PROCEEDING WITH THE INSTALLATION OF NEW
WORK.
EXISTING BUILDING NOTE
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:2
A M
01.12.2026
CONDOC
AJL
K. RIGBY
A140
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
ROOF PLAN
GENERAL NOTES AND LEGENDS:
1/8" = 1'-0" , ROOF PLAN 0'
SCALE : 1/8" = 1'-0"
8'4' 24'16' n
KEYED NOTES:
1 EXISTING ROOF HATCH
2 EXISTING ROOFING SYSTEM TO REMAIN. MUST MAINTAIN EXISTING ROOFING
WARRANTY.
3 EXISTING EQUIPMENT TO REMAIN
4 EXISTING GREENHOUSE ROOF SYSTEM TO REMAIN, PROTECT.
5 NEW MECHANICAL EQUIPMENT, SEE MECHANICAL DRAWINGS.
6 PATCH EXISTING ROOF SYSTEM TO PROVIDE A LEAK PROOF SEAL, MAINTAIN
EXISTING ROOFING WARRANTY.
EXISTING ROOFING SYSTEM WARRANTY TO BE MAINTAINED BY ALL NEW ROOFING
WORK & PATCH & REPAIRS.
12'-0 " O
.C
2'-0
O.C
4'-0" O.C.
12'-0" O.C.
LATERAL RESTRAINT: BEGIN
WITHIN 6" OF WALL (3) 12 GA.
SPLAY WIRES @ 12'-0" O.C. (EA
DIRECTION) AND
COMPRESSION POST TO
STRUCTURE
9 GA. HANGER WIRE TYPICAL @
4'-0" O.C. U.NO. EACH
DIRECTION., (3) TURNS MIN, ON
WIRE TIE
MAIN RUNNER
CROSS RUNNER
STEEL STUD
COMPRESSION POST
ANCHOR TO DECK.
#12 HANGER WIRE.
MAIN BEAM.
CROSS TEE.
45° or less
45° or less 45° or less
45° or less
POP RIVET TEE TO ANGLE.
7/8" WALL ANGLE.
9 GA. WIRE WITHIN 8" OF WALL.
STABILIZER BAR.
2" WALL ANGLE.
9 GA. WIRE WITHIN 8" OF WALL.
HEAVY DUTY "T" BAR.
UNATTACHED WALL:
ATTACHED WALL:
A
LL
I D
E A
S
D E S
IG
N S
A R R A
N G
E M
E N
TS
A
N D
P
LA
N S I N
D
IC
A
TE
D O
R R
E P R E S E N
TE
D
B Y T
H
IS
D R A
W
IN
G A
R E O
W N
E D
B Y A
N D
T H
E P
R O
P E R
TY
O F A
J C
A R C
H
IT
E C
TS
P
C A
N D
W E R E C
R E A
TE
D
E V O
LV
E D
A
N D
D E V E
LO
P E D
F O
R U
S E O
N A
N D
I N
C O
N N
E C
TI
O
N W
IT
H
T H
E S
P E C
IF
IE
D P
R O
J E C
T.
N
O N
E O
F T
A
S
D E S
IG
N S, A R R A
N G
E M
E N
TS
O
R P
LA
N
S S
H A
LL
B
E U
S E D
B Y O
R D
IS
C
LO
S E D
T O
A N
Y P
E R S O
N
F
IR
M
O R C
O R P O
R A
TI
O
N F
O R A
N Y P
U R P O
S E W
H A
TS
O
E V E R W
IT
H
O U
T W
R
IT
TE
N
C O
N S E N
T O
F A
J C
A R C
H
IT
E C
TS
P
C
W R
IT
TE
N
D
IM
E N
S
IO
N S O
N T
H E S E D
R A
W
IN
G S S
H A
LL
H
A V E P
R E C
E D
E N
C E O
V
A
LE
D
IM
E N
S
IO
N S
C O
N
TR
A C
TO
R S S
H A
LL
V
E R
IF
Y A
N D
B E R
E S P O
N S
IB
LE
F
O R A
LL
D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S O
N T
H E J
O B A
N D
T H
IS
O
F F
IC
E M
U S T
B E N
O
TI
F
IE
D O
F A
N Y V
A R
IA
TI
O
N F
R O
M T
H E D
IM
E N
S
IO
N S A
N D
C O
N D
IT
IO
N S S
H O
W N
B Y T
H E S E D
R A
W
IN
G S
W A
R N
IN
G
R E P R O
D U
C
TI
R E O
F I S A
C R
IM
IN
A
L O
F F E N
S E U
N D
E R
U
.S .C
S E C
U
N A
U
TH
O R
IZ
E D
D
IS
C
LO
S U
R E M
A Y C
O N
S
TI
TU
TE
T R A
D E S
E C
R E T
M
IS
A P P R O
P R
IA
TI
O
N I N
V
IO
LA
TI
O N
O F I .C
.2
-2 -3
-1
E T.
S E Q
A
N D
O
TH
E R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
01.12.2026
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
/2
-3
U S D
A B e e
L a b L o g a n
H V
A C a la rs e n a jc a rc h it e c ts
.c o m .r v t
/8
/2
:2
:3
A M
01.12.2026
CONDOC
AJL
K. RIGBY
A500
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
DETAILS
3" = 1'-0" , TYP. 2' x 4' SUSPENDED CEILING BRACING
3" = 1'-0" , CEILING - TYP. SEISMIC CEILING BRACING
3" = 1'-0" , TYP. SEISMIC SUSPENDED CEILING DETAIL
* NOTE: EXISTING CEILING
SYSTEM TO REMAIN & BE RE-USED
* NOTE: EXISTING CEILING
SYSTEM TO REMAIN & BE RE-USED
* NOTE: EXISTING CEILING
SYSTEM TO REMAIN & BE RE-USED
L L I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T
S A
N D
P L A
N S
I N
D
IC
A T
E D
O R
R E
P R
E S
E N
T E
D B
Y T
H
IS
D R
A W
IN
G
A R
E O
W N
E D
B Y
A N
D T
H E
P R
O P
E R
T Y
O F
A J C
A R
C H
IT
E
C T
S P
C A
N D
W E
R E
C R
E A
T E
D
E V
O L V
E D
A
N D
D E
V E
L O
P E
D F
O R
U S
E O
N A
N D
I N
C O
N N
E C
T
IO
N W
IT
T
E
S P
E C
IF
IE
D P
R O
J E
C T
N
O N
E O
F T
H E
I D
E A
S
D E
S
IG
N S
A
R R
A N
G E
M E
N T
S O
R P
L A
N S
S H
A L L B
E U
S E
D B
Y O
R D
IS
C
L O
S E
D T
O A
N Y
P E
R S
O N
F
IR
M
O
R C
O R
P O
R A
T
IO
N F
O R
A N
Y P
U R
P O
S E
W H
A T
S O
E V
E R
W
IT
H O
U T
W R
IT
T
E N
C O
N S
E N
T O
F A
J C
A R
C H
IT
E
C
P
W
R
IT
T E
N D
IM
E
N S
IO
N
S O
N T
H E
S E
D R
A W
IN
G
S S
H A
L L H
A V
E P
R E
C E
D E
N C
E O
V E
R S
C A
L E
D
IM
E N
S
IO
N S
C
O N
T R
A C
T O
R S
S H
A L L V
E R
IF
Y
A N
D B
E R
E S
P O
N S
IB
L E
F O
R A
L L D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
O N
T H
E J
O B
A N
D T
H
IS
O F
F
IC
E M
U S
T B
E N
O T
IF
IE
D
F
Y V
A R
IA
T
IO
N
F R
O M
T H
E D
IM
E
N S
IO
N
S A
N D
C O
N D
IT
IO
N S
S H
O W
N B
Y T
H E
S E
D R
A W
IN
G
S
W A
R N
IN
G
R
E P
R O
D U
C T
IO
N
H E
R E
O F
I S
A C
R
IM
IN
A
L O
F F
E N
S E
U N
D E
R
U
.S .C
S
E C
U N
A U
T H
O R
IZ
E
D D
IS
C
L O
S U
R E
M A
Y C
O N
S T
IT
U
T E
T R
A D
E S
E C
R
M
IS
A P
P R
O P
R
IA
T
IO
N I N
V
IO
L A
T
IO
N O
F I .C
.2 -2
-3 -1
E T
S
E Q
A
N D
O T
H E
R L
A W
S
SHEET NUMBER:
ISSUE DATE:
ISSUE TYPE:
DRAWN BY:
CHECKED BY:
PROJECT#:
PROJECT DESCRIPTION
SHEET NAME:
REVISIONS
ARCHITECT / CONSULTANT
703 east 1700 south salt lake city, ut 84105 ajcarchitects.com
A u to d e sk
D o c s:
-3
U
S D
A B e e
L a b H
V A
C L o g a n
-M e c h U
S D
A B e e
.r v t
:5
:3
P
M
01.12.2026
CONDOC
RHB
RHB
ME001
2024-32
POLLINATING INSECT-BIOLOGY
MANAGEMENT, SYSTEMATICS
RESEARCH UNIT
UTAH STATE UNIVERSITY
880 EAST 1400 NORTH
LOGAN, UT 84131
UPGRADE HVAC FOR
USDA BEE
LAB/HEADHOUSE
FACILITY
MECHANICAL COVER
SHEET
MECHANICAL SHEET INDEX
ME001 MECHANICAL COVER SHEET
ME501 MECHANICAL DETAILS
ME601 MECHANICAL SCHEDULES
ME602 MECHANICAL SCHEDULES
MD101 LEVEL 1 MECHANICAL DEMO PLAN
MD102 ROOF MECHANICAL DEMO PLAN
MH101 LEVEL 1 MECHANICAL PLAN
MH102 ROOF MECHANICAL PLAN
MH401 ENLARGED MECHANICAL PLANS
ABBREVIATIONS
NOTE: ALL ABBREVIATIONS MAY NOT BE USED.
DEFINITIONS
NOTE: ALL DEFINITIONS MAY NOT BE USED.
INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS,
NOTES, OR SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR
SCHEDULES IN THE SPECIFICATIONS, AND SIMILAR REQUIREMENTS IN THE
CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN", "NOTED",
"SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE
THE REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.
DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED",
"SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY
THE ENGINEER", "REQUESTED BY THE ENGINEER", AND SIMILAR PHRASES.
APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE
ENGINEER'S ACTION ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND
REQUESTS, IS LIMITED TO THE ENGINEER'S DUTIES AND RESPONSIBILITIES AS
STATED IN GENERAL AND SUPPLEMENTARY CONDITIONS.
FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO
THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY,
INSTALLATION, AND SIMILAR OPERATIONS."
INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT
SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION,
PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING,
PROTECTING, CLEANING, AND SIMILAR OPERATIONS."
PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE
AND READY FOR THE INTENDED USE."
INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY
THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-
SUBCONTRACTOR, FOR PERFORMANCE OF A PARTICULAR CONSTRUCTION
ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR
OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE
OPERATIONS THEY ARE ENGAGED TO PERFORM.
(E) EXISTING
(F) FUTURE
AC AIR CONDITION(-ING,-ED)
APD AIR PRESSURE DROP
BD BALANCING DAMPER
BHP BRAKE HORSE POWER
BTU BRITISH THERMAL UNIT
BTUH BTU/HOUR
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CV CONTROL VALVE
DB DRY BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RECIRC
DP DEPTH, DEEP, OR DROP IN PRESSURE
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFICIENCY
ELEC ELECTRIC
ELEV ELEVATION
ENT ENTERING
EVAP EVAPORAT(-E, -ING, -ED, -OR)
EWT ENTERING WATER TEMPERATURE
EXT EXTERNAL
FD FIRE DAMPER
FLA FULL LOAD AMPS
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
FSD FIRE SMOKE DAMPER
GE GREASE EXHAUST
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HD HEAD
HG MERCURY
HP HORSEPOWER
HR HOUR
HTG HEATING
HZ HERTZ (FREQUENCY)
IN INCH
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LH LATENT HEAT
LRA LOCKED ROTOR AMPS
LVG LEAVING
LWT LEAVING WATER TEMPERATURE
MBH THOUSAND BTU PER HOUR
MCA MINIMUM CIRCUIT AMPS
MFR MANUFACTUR(-ER, -ED)
NC NORMALLY CLOSED OR NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPSH NET POSITIVE SUCTION HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
OZ OUNCE
PD PRESSURE DROP OR…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .