Attachment 2 - EHRM Upgrade -Phase 2 Construction Drawings - Part 2.pdf

PDF 16 MB Posted

Attached to
Y1DA--578-21-706 EHRM Training and Admin Space Support - Phase 2 - Hines, IL (VA-22-00052631)
Solicitation number
36C77622B0050
Issued by

About this file

This federal contract opportunity solicitation seeks proposals for the EHRM Training and Admin Space Support - Phase 2 project located in Hines, IL. The Department of Veterans Affairs Technology Acquisition Center Austin is soliciting proposals to provide construction drawings as detailed in Attachment 2 for upgrading and expanding the EHRM facility. Proposals are due by January 31, 2022. The selected contractor will be awarded a firm fixed-price contract to complete the required drawings by June 30, 2022 to support renovations of the training and administration spaces at the Hines VA Medical Center. The scope of work involves preparing architectural, mechanical, electrical and civil drawings to plan for renovations and additions to the existing facility as outlined in the statement of work.

View the file

Other files

File Type Posted
36C77622B0050 0004.docx DOCX document
36C77622B0050 0003.docx DOCX document
36C77622B0050 0002.pdf PDF
36C77622B0050 0001.zip ZIP file
Attachment 10 - Interim Life Safety Measures (ILSM) 02.pdf PDF
Attachment 19 - Hines VA Campus Site Plan.pdf PDF
Attachment 15 - No Smoking Policy 10-1-19.pdf PDF
Attachment 11 - Infection Control Risk Assessment (ICRA).pdf PDF
Attachment 1 - EHRM Upgrade - Phase 2 Construction Drawings - Part 1.pdf PDF
Attachment 8 - Above Ceiling Entry and Wall Construction Permits.pdf PDF
Attachment 3 - EHRM Training and Admin Space Support - Specifications- Rev1.pdf PDF
36C77622B0050_1.docx DOCX document
Attachment 12 - Contractor PIV Instructions and Form.pdf PDF
Attachment 14 - OIT Horizontal Cable Requirements.pdf PDF
Attachment 23 - VHA Supplemental Contract Requirements for Combatting COVID-1912-14-2021.docx DOCX document
Attachment 13 - Contractor Parking.pdf PDF
Attachment 20 - Limitations on Subcontracting.docx DOCX document
Attachment 16 - Infection Control Barrier Sample.pdf PDF
Attachment 00 - SOW 578-21-706 Construction.docx DOCX document
Attachment 17 - Hines COVID-19 Guidelines.pdf PDF
Attachment 9 - Pre-Construction Risk Assessment (PCRA).pdf PDF
Attachment 5 - Safety and Health During Construction Activities.pdf PDF
Attachment 4 - Pre-Construction Checklist.pdf PDF
Attachment 21 - Contractor Safety and Environmental Form.docx DOCX document
Attachment 6 - Cutting Welding and Other Hot Work.pdf PDF
Attachment 7 - Dig Permit SOP Form.pdf PDF
Attachment 22 - Hines Construction Wage Rates 6-24-2022 Cook.pdf PDF
Attachment 18 - Hines Underground Utility Plan.pdf PDF
Show all 28

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

C D E F G H I J K L M N O P

AE301

/A

I8

FREIGHT

ELEVATOR

OFFICE (1)

SLC-1 ACT-1

P-1B-2

OFFICE (1)

SLC-1 ACT-1

P-1B-2

TR

SLC-1 ETR

ETRETR

OFFICE (1)

SLC-1 ACT-1

P-1B-2

OFFICE (1)

SLC-1 ACT-1

P-1B-2

OFFICE (1)

SLC-1 ACT-1

P-1B-2

BREAK (6)

SLC-1 ACT-1

P-1B-2

CORRIDOR

C1

SLC-1 ACT-1

P-1B-2

/4

/4

110A

LOBBY

SLC-1 ACT-1

P-1B-2

ELEVATOR

E1-A

S2-A

STAIR

S2-A

SLC-1 P-3

P-1B-2

ELEVATOR EQUIPMENT

SLC-1 P-3

P-1-

UNISEX RESTROOM

CT-1 ACT-1

CTW-1CBT-1

UNISEX RESTROOM

CT-1 ACT-1

CTW-1CBT-1

MECHANICAL

ETR P-3

P-1- STAIR

S1-A

SLC-1 P-3

P-1B-2

SHELL SPACE

ELECTRICAL

B

112A

118A

FUTURE RESTROOMS

CPT-3

XXX

XXX

XX

XX

XX

XX

ROOM NUMBER

CEILING FINISH

WALL FINISH

ROOM NAME

FLOOR FINISH

WALL BASE FINISH

FINISH KEY

REFER TO SHEET AI800

F I N I S H N O T E S:

A. SEE ROOM FINISH SCHEDULE SHEET I800.

B. ALL FLOORING MATERIALS TO BE SLIP RESISTANT.

C. ALL FINISHES TO BE CLASS A OR B

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:3

P

M

AI801

ARCHITECTURAL FIRST FLOOR

FINISH PLAN

02/23/2022 PH TD

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

N

1/8" = 1'-0"

FIRST FLOOR FINISH PLAN

KEYPLAN

D R A W I N G N O T E S :

1 LOCKERS - RELOCATED BY VA

2 INFILL WALL WITH TYPE 4A 6" CMU WALL.

3 SEMI RECESSED FIRE EXTINGUISHER CABINET

Revisions: Date:

BID DOCUMENTS 02/23/2022

UPDN

C D E F G H I J K L M N O P

6/AI810

5/AI810

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

CLASSROOM (17)

CPT-1 ACT-1

P-1B-1

TR

SLC-1 P-3

P-1B-2

MECHANICAL ROOM

SLC-1 P-3

P-1B-2

BREAK ROOM

SLC-1 ACT-1

P-5B-2

STAIR

S2-B

SLC-1 P-3

P-1B-2

FREIGHT ELEVATOR

E2

CORRIDOR

C5

CPT-2 P-3

P-1B-2

ELEVATOR

E1-B

CERNER AND COMMAND

CENTER (30)

CPT-1 ACT-1

P-1B-1

PLANNING AND PREP

CPT-1 ACT-1

P-1B-1

CONFERENCE ROOM

CPT-1 ACT-1

P-4B-1

VENDING

SLC-1 ACT-1

P-5B-2

AE501

SIM

ELEVATOR LOBBY

CPT-2 P-3

P-1B-2

STAIR

S3-B

SLC-1 P-3

P-1B-2

CORRIDOR

C2

SLC-1 ACT-2

P-1B-2

CORRIDOR

C2

SLC-1 ACT-2

P-1B-2

CORRIDOR

C3

CPT-2 P-3

P-1B-2

CORRIDOR

C4

CPT-2 ACT-2

P-1B-2

WOMEN'S RESTROOM

CT-1 ACT-1

CTW-1CBT-1

MEN'S RESTROOM

CT-1 ACT-1

CTW-1CBT-1

ELEC.

SLC-1 P-3

P-1B-2

HAC

CT-1 P-3

P-1CBT-1

SLC-1

SLC-1

SLC-1

/Q

H

/Q

H

4/QH401

1/QH401

AE502

XXX

XXX

XX

XX

XX

XX

ROOM NUMBER

CEILING FINISH

WALL FINISH

ROOM NAME

FLOOR FINISH

WALL BASE FINISH

FINISH KEY

REFER TO SHEET AI800

F I N I S H N O T E S:

A. SEE ROOM FINISH SCHEDULE SHEET I800.

B. ALL FLOORING MATERIALS TO BE SLIP RESISTANT.

C. ALL FINISHES TO BE CLASS A OR B

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:3

P

M

AI802

ARCHITECTURAL SECOND FLOOR

FINISH PLAN

02/23/2022 PH TD

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

N

1/8" = 1'-0"

SECOND FLOOR FINISH PLAN

KEYPLAN

24" 24" 24" 24" 24" 24"

24" 24" 24" 24" 24" 24"

36"36"

36" 36" 36" 36"

36"36"36"36"48"

48" 36" 36" 36" 36"

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:4

P

M

AI810

ARCHITECTURAL INTERIOR

ELEVATIONS

02/23/2022 PH TD

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

1/4" = 1'-0"

BREAK ROOM 107 - EAST WALL

1/4" = 1'-0"

PLANNING AND PREP 242 - CASEWORK

1/4" = 1'-0"

BREAKROOM 229 - CASEWORK

DM

DM

DM

DM

TR/USB

TR/USB

TR/USB

D

D

D

WP1

2D

D4

D

D4

D

D

D

D

D

G E N E R A L N O T E S:

H I

/2

20' - 0"

EQ. 17' - 4" EQ.

/Q

H

/Q

H

4/QH401

1/QH401

6' - 0" 1' - 0"

1' - 0" 6' - 0"

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:1

P

M

QH401

ENLARGED CLASSROOM

FURNITURE PLANS

02/23/2022 PH JK

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

D R A W I N G N O T E S :

1 4 X 6 MARKER BOARD.

2 MONITOR SEE TECHNOLOGY DRAWINGS - PROVIDE BLOCKING IN WALL.

3 SUPPLY SHELF (VV).

N

1/4" = 1'-0"

ENLARGED PLAN - TYPICAL INTERIOR CLASSROOM

A. ALL ITEMS CONTRACTOR SUPPLIED AND CONTRACTOR INSTALLED

(CC) UNLESS NOTED OTHERWISE.

B. VV = VA SUPPLIED AND INSTALLED

C. LECTERN, TABLES, AND CHAIRS ARE VV.

1/4" = 1'-0"

TYPICAL CLASSROOM 1

1/4" = 1'-0"

TYPICAL CLASSROOM 2

1/4" = 1'-0"

TYPICAL CLASSROOM 4

1/4" = 1'-0"

TYPICAL CLASSROOM 3

C D E F G H I J K L M N O P

AE301

FREIGHT

ELEVATOR

121 SF

OFFICE (1)

119 SF

OFFICE (1)

114 SF

TR

120 SF

OFFICE (1)

120 SF

OFFICE (1)

120 SF

OFFICE (1)

339 SF

BREAK (6)

608 SF

CORRIDOR

C1

/4

/4

404 SF

LOBBY

61 SF

ELEVATOR EQUIPMENT

75 SF

ELEVATOR

E1-A

86 SF

UNISEX RESTROOM

86 SF

UNISEX RESTROOM

129 SF

STAIR

S2-A

108 SF

ELECTRICAL

237 SF

STAIR

S1-A

4667 SF

SHELL SPACE

SS

/A

I8

G E N E R A L N O T E S:

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:5

P

M

QH101

FIRST FLOOR FURNITURE PLAN

02/23/2022 PH TD

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

N

1/8" = 1'-0"

FIRST FLOOR FURNITURE PLAN

KEYPLAN

F U R N I T U R E N O T E S :

1 LOCKERS - RELOCATED BY VA

A. ALL TABLES, CHAIRS, WORKSTATIONS, AND DESKS SHOWN ON THIS PLAN ARE

FOR REFERENCE ONLY AND ARE VA FURNISHED AND INSTALLED.

B. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS

SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR

CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY

TO PROPERLY ACCOMMODATE THE NEW MATERIALS.

UPDN

C D E F G H I J K L M N O P

729 SF

CLASSROOM (17)

604 SF

CLASSROOM (17)

604 SF

CLASSROOM (17)

604 SF

CLASSROOM (17)

591 SF

CLASSROOM (17)

625 SF

CLASSROOM (17)

605 SF

CLASSROOM (17)

605 SF

CLASSROOM (17)

606 SF

CLASSROOM (17)

606 SF

CLASSROOM (17)

605 SF

CLASSROOM (17)

600 SF

CLASSROOM (17)

599 SF

CLASSROOM (17)

904 SF

CLASSROOM (17)

603 SF

CLASSROOM (17)

603 SF

CLASSROOM (17)

866 SF

CORRIDOR

C4

599 SF

CLASSROOM (17)

602 SF

CLASSROOM (17)

118 SF

TR

1572 SF

MECHANICAL ROOM

445 SF

BREAK ROOM

218 SF

STAIR

S2-B

82 SF

FREIGHT ELEVATOR

E2

1657 SF

CORRIDOR

C5

75 SF

ELEVATOR

E1-B

216 SF

VENDING

264 SF

MEN'S RESTROOM

265 SF

WOMEN'S RESTROOM

146 SF

STAIR

S3-B

62 SF

HAC

563 SF

ELEVATOR LOBBY

1936 SF

CERNER AND COMMAND

CENTER (30)

580 SF

PLANNING AND PREP

1832 SF

CORRIDOR

C2

135 SF

STAIR

S1-B

6/AI810

5/AI810

3/AE401

/A

E

/A

E

6/AE401

/A

E

8/AE401

/A

E

10/AE401

QH401

3' - 9"

/4

/Q

H

/Q

H

4/QH401

1/QH401

6' - 0"

85'

99'-6"

G E N E R A L N O T E S:

02/23/2022

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS

321 4 5 6 7 8 9 10

B

IM

/H in e s E

H R

M T ra in in g

C e n te r/ F

F E

H in e s

T ra in in g C e n te r_

B rv t

/2

/2

:1

:0

P

M

QH102

SECOND FLOOR FURNITURE PLAN

02/23/2022 PH TD

EHRM TRAINING AND ADMIN SPACE

SUPPORT

578-21-706

HINES, IL

BID DOCUMENTS

EDWARD HINES

JR. VAMC

N

1/8" = 1'-0"

SECOND FLOOR FURNITURE PLAN

D R A W I N G N O T E S :

1 VENDING MACHINES BY OTHERS

KEYPLAN

A. ALL TABLES, CHAIRS, WORKSTATIONS, AND DESKS SHOWN ON THIS PLAN ARE

FOR REFERENCE ONLY AND ARE VA FURNISHED AND INSTALLED.

B. WHERE EXISTING SURFACES ARE TO BE REFINISHED OR ARE TO SERVE AS

SUBSTRATE FOR THE ATTACHMENT OR APPLICATION OF NEW MATERIALS OR

CONSTRUCTION, PREPARE OR ALTER THE EXISTING SURFACES AS NECESSARY

TO PROPERLY ACCOMMODATE THE NEW MATERIALS.

ABBREVIATIONS

AC - AIR COMPRESSOR

ACC - ACCESS

AD - ACCESS DOOR

ADB - ACID DILUTION BASIN

ADJ - ADJUSTABLE

AFF - ABOVE FINISHED FLOOR

AFG - ABOVE FINISHED GRADE

ALT - ALTERNATE

AP - ACCESS PANEL

APPROX - APPROXIMATE

ARCH - ARCHITECT OR ARCHITECTURAL

ASSY - ASSEMBLY

BFP - BACKFLOW PREVENTER

BLDG - BUILDING

BOB - BOTTOM OF BEAM

BOD - BOTTOM OF DUCT

BOE - BOTTOM OF EQUIPMENT

BOF - BOTTOM OF FOOTING

BOG - BOTTOM OF GRILLE

BOP - BOTTOM OF PIPE

BOT - BOTTOM

BTWN - BETWEEN

CA - COMPRESSED AIR

CFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CLG - CEILING

CONN - CONNECT OR CONNECTION

CONTR - CONTRACTOR

COR - CONTRACTING OFFICER'S REPRESENTATIVE

CORR - CORRIDOR

CTR - CENTER

CWS - COMBINATION WATER SERVICE

D - DEPTH

DET - DETAIL

DIA - DIAMETER

DIM - DIMENSION

DN - DOWN

DS - SPRINKLER (DRY)

DWG - DRAWING

EA - EACH

EC - ELECTRICAL (DIVISION 26)

EJ - EXPANSION JOINT

ELEC - ELECTRICAL

ELEV - ELEVATOR

EQ - EQUAL

EQUIP - EQUIPMENT

ETR - EXISTING TO REMAIN

EQS - EQUIPMENT SUPPLIER

EXP - EXPANSION

EXT - EXTERIOR

EX - EXISTING

F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER MAIN)

FCE - FIRE CONTROL EQUIPMENT

FCO - FLOOR CLEANOUT

FD - FLOOR DRAIN

FDC - FIRE DEPARTMENT CONNECTION

FDV - FIRE DEPARTMENT VALVE

FF - FINISHED FLOOR ELEVATION

FHC - FIRE HOSE CABINET

FLR - FLOOR

FPM - FEET PER MINUTE

FR - FIRE RISER

FS - FIRE SERVICE

FSC - FIRE SUPPRESSION (DIVISION 21)

FT - FEET

FTG - FOOTING

GA - GAUGE

GAL - GALLON

GALV - GALVANIZED

GC - GENERAL TRADES

GPM - GALLONS PER MINUTE

HC - HVAC (DIVISION 23)

HD - HUB DRAIN

HP - HORSEPOWER OR HIGH POINT

HR - HOSE REEL

HT - HEAT TRACE

HVAC - HEATING, VENTILATING, AND AIR CONDITIONING

ID - INSIDE DIAMETER

INV - INVERT ELEVATION

IN - INCHES

JS - JANITOR SINK

L - LENGTH

LBS - POUNDS

MAX - MAXIMUM

MB - MOP BASIN

MC - MECHANICAL (DIVISION 23)

MEZZ - MEZZANINE

MFR - MANUFACTURER

MIN - MINIMUM

MISC - MISCELLANEOUS

MTD - MOUNTED

MTG - MOUNTING

N/C - NORMALLY CLOSED

NIC - NOT IN CONTRACT

N/O - NORMALLY OPEN

NOM - NOMINAL

NPT - NATIONAL PIPE THREAD

NTS - NOT TO SCALE

OA - OUTDOOR AIR

OD - OUTSIDE DIAMETER

OFCI - OWNER FURNISHED CONTRACTOR

INSTALLED

OFOI - OWNER FURNISHED OWNER INSTALLED

PC - PLUMBING (DIVISION 22)

OR PUMPED CONDENSATE RETURN

PIV - POST INDICATOR VALVE

PLBG - PLUMBING

PS - PRE-ACTION/DELUGE SPRINKLER

PRESS - PRESSURE

PRV - PRESSURE REGULATING VALVE

PSF - POUNDS PER SQUARE FOOT

PSI - POUNDS PER SQUARE INCH

PSV - PRESSURE SUSTAINING VALVE

PSIG - POUNDS PER SQUARE INCH GAUGE

RAD - RADIUS

REC - RECESSED

REQD - REQUIRED

RI - ROUGH IN

RPM - REVOLUTIONS PER MINUTE

S - SPRINKLER (WET)

SCH - SCHEDULE

SD - SPRINKLER DRAIN

SHT - SHEET

SK - SINK

SPEC - SPECIFICATIONS

SQ - SQUARE

STD - STANDARD

STRUC - STRUCTURAL OR STRUCTURE

SUC - SITE UTILITY CONTRACTOR

TEMP - TEMPERATURE

TOB - TOP OF BEAM

TOD - TOP OF DUCT

TOE - TOP OF EQUIPMENT

TOF - TOP OF FOOTING

TOJ - TOP OF JOIST

TOP - TOP OF PIPE

TOS - TOP OF SLAB OR TOP OF STEEL

TYP - TYPICAL

UNO - UNLESS NOTED OTHERWISE

VEL - VELOCITY

VIB - VALVE IN BOX

VOL - VOLUME

W/ - WITH

W/O - WITHOUT

WIV - WALL INDICATOR VALVE

WS - WATER SERVICE

VALVES AND FITTINGS

T

P

FOB

FOT

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

GAUGE - PRESSURE

GAUGE - TEMPERATURE OR THERMOMETER

UNION

CLEANOUT

STRAINER

STRAINER - WITH A BLOW DOWN VALVE AND HOSE

CONNECTION

VALVE - DRAIN WITH HOSE END CONNECTION

VALVE - PRESSURE REGULATING

VALVE - SAFETY RELIEF. PIPE DISCHARGE AIR

GAPPED TO FLOOR DRAIN UNLESS NOTED

OTHERWISE.

PLUG - PRESSURE AND TEMPERATURE TEST

TRAP PRIMER

GAUGE - VACUUM WITH STOP

CLEANOUT - TO GRADE OR FINISHED FLOOR

END CAP

MIXING FAUCET

PLUG

HOSE BIB

WALL HYDRANT

VALVE - PLUG

VALVE - SHUTOFF AND BOX

VALVE - SHUTOFF ON RISER

V

VB

TP

CO

VALVE - SOLENOID

S

P/T VALVE - PRESSURE AND TEMPERATURE SAFETY

RELIEF. PIPE DISCHARGE AIR GAPPED TO

FLOOR DRAIN UNLESS NOTED OTHERWISE.

VALVE - CHECK

VALVE - SHUTOFF: BALL, GATE, BUTTERFLY VALVE

(REFER TO SPECIFICATIONS FOR REQUIRED TYPE

BASED ON APPLICATIONS)

AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN

AND OUT

VALVE - COMBINATION SHUTOFF AND

BALANCING (REFER TO SPECIFICATIONS FOR

REQUIRED TYPE BASED ON APPLICATIONS)

A1

P1 P1OR

A1

OH

P2

B

P2

GENERAL FLOOR PLAN NOTES

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

FIRE SUPPRESSION HAZARD CLASSIFICATION AND

HAZARD CLASSIFICATION GROUP

SECTION: 1 = SECTION DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

EQUIPMENT REFERENCE. LETTER DESIGNATION

VARIES. REFER TO SCHEDULES.

EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK.

LETTER DESIGNATIONS REFER TO SCHEDULES.

CONNECT TO EXISTING

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH

IT IS SHOWN UNLESS NOTED OTHERWISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

EXISTING PIPE TO REMAIN

EXISTING PIPE TO BE REMOVED

EXPANSION JOINT

WATER METERM

PIPING SYMBOLS

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE:

BULLHEAD TEE'S ARE NOT PERMITTED)

DIRECTION OF PITCH

DROP

ELBOW DOWN

ELBOW UP

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

D

R

PIPE RISER

BC

TC

FLEX PIPING

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ADDITIONALLY, ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT.

FIRE SUPPRESSION SYMBOLS

PIPING DESIGNATIONS

FS

PIV

S

CONCEALED PENDENT SPRINKLER

FIRE HYDRANT

FLOW SWITCH

GATE VALVE OS&Y

INSTITUTIONAL PENDENT SPRINKLER

PENDENT SPRINKLER

POST INDICATOR VALVE

RECESSED PENDENT SPRINKLER

SIDE WALL SPRINKLER

SUPERVISED VALVE

UPRIGHT SPRINKLER

FIRE DEPARTMENT VALVE

SPRINKLER PIPE (DRY)

FIRE SUPPRESSION (STANDPIPE/

SPRINKLER MAIN)

FIRE SERVICE

PRE-ACTION / DELUGE SPRINKLER PIPE

SPRINKLER PIPE (WET)

SPRINKLER DRAIN PIPE

DS

F

FS

PS

S

SD

COMMMMBINATION FIRE SUPPRESSION &

DOMESTIC WATER SERVICE

CWS

A PROVIDE A COMPLETE RENOVATION TO AN EXISTING FIRE SUPPRESSION

SPRINKLER SYSTEM IN THE RENOVATED AREA.

B COORDINATE WORK WITH VAMC, PHASING PLAN AND OTHER TRADES. OFFSET

AND/OR RELOCATE EXISTING SERVICES TO ACCOMMODATE NEW WORK OF

OTHER TRADES.

C DESIGN SERVICES SHALL FOLLOW ALL VA STANDARD DESIGN PRACTICES,

DETAILS, SPECIFICATIONS AND SITE SPECIFIC COR REQUIREMENTS AS WELL AS

WORK SHOWN ON THESE DOCUMENTS. ALL DEVIATIONS FROM

AFOREMENTIONED REQUIREMENTS SHALL BE APPROVED BY THE COR.

D VERIFY THAT THERE IS ADEQUATE SPACE TO INSTALL ALL NEW PIPING

REQUIRED TO COMPLETE THIS WORK.

E ALL SPRINKLER PIPING IS LOCATED ABOVE THE CEILING (AT THE BOTTOM OF

STRUCTURE IN EXPOSED STRUCTURAL AREAS), UNLESS OTHERWISE INDICATED.

F THE BASIS OF DESIGN OF SPACING AND SIZING FOR THE COMPLETE FIRE

SUPPRESSION SPRINKLER SYSTEM SHALL BE FOR A WET PIPE SYSTEM

HYDRAULICALLY CALCULATED FOR A:

1 LIGHT HAZARD AREA LIMITED TO A MAXIMUM OF 225 SQ. FT. PER SPRINKLER

WITH THE DENSITY OF 0.10 GPM/SQ. FT. OVER THE MOST REMOTE 1500 SQ.

FT. PROVIDE AN ADDITION OF 100 GPM HOSE ALLOWANCE.

2 ALL MECHANICAL, ELECTRICAL AND SIMILAR SPACE AREAS SHALL BE

ORDINARY HAZARD (GROUP 1) LIMITED TO A MAXIMUM OF 130 SQ. FT. PER

SPRINKLER WITH A DENSITY OF 0.15 GPM/SQ. FT. PROVIDE AN ADDITION OF

250 GPM HOSE ALLOWANCE.

3 ALL STORAGE, TRASH, FILE STORAGE AND SIMILAR SPACE AREAS SHALL BE

ORDINARY HAZARD (GROUP 2) LIMITED TO A MAXIMUM OF 130 SQ. FT. PER

SPRINKLER WITH A DENSITY OF 0.20 GPM/ SQ. FT. PROVIDE AN ADDITION OF

250 GPM HOSE ALLOWANCE.

G PROVIDE SPRINKLER LOCATIONS AND RELATED PIPING.

H THE ENTIRE SPRINKLER SYSTEM SHALL CONFORM TO VAMC STANDARDS, RULES

AND REGULATIONS. REFER TO VA FIRE PROTECTION DESIGN MANUAL.

I CAREFULLY COORDINATE THE LOCATION OF ALL SPRINKLERS AND PIPING WITH

ALL OTHER TRADES AND THE ARCHITECT.

J VERIFY THE LOCATION OF ALL LIGHTING FIXTURES AND AIR DEVICES BEFORE

INSTALLATION OF SPRINKLERS.

K PROVIDE SPRINKLER PIPING LAYOUT AND SIZING.

L ALL SPRINKLER LOCATIONS MUST BE COORDINATED WITH ALL EQUIPMENT

KINDRED TO OTHER TRADES. SPRINKLER LOCATIONS MUST BE APPROVED BY

THE ARCHITECT BEFORE WORK COMMENCES. REFER TO THE ARCHITECTURAL

AND REFLECTIVE CEILING PLANS FOR ADDITIONAL INFORMATION ON ALL CEILING

TYPES, HEIGHTS AND OTHER ARCHITECTURAL FEATURES.

M MAKE NECESSARY FLOW TESTS, LAYOUT SYSTEMS, OBTAIN APPROVALS FROM

THE AUTHORITIES HAVING JURISDICTION PRIOR TO BEGINNING ANY

FABRICATION OR INSTALLATION WORK.

N SPRINKLER PIPING SHALL BE 1" MINIMUM SIZE.

O SPRINKLERS (UNLESS OTHERWISE NOTED):

EXPOSED AREAS - UPRIGHT OR PENDENT TYPE - STANDARD BRASS

CEILING AREAS - RECESSED PENDENT TYPE

P ALL HEADS SHALL BE UL LISTED AND FM APPROVED.

Q SPRINKLERS SHALL BE "QUICK RESPONSE" TYPE IN ALL AREAS EXCEPT: HIGH

TEMPERATURE AREAS, TELECOMMUNICATION, ELECTRICAL SWITCHGEAR,

ELEVATOR EQUIPMENT ROOMS AND ELEVATOR SHAFTS.

R ALL PENDENT TYPE SPRINKLERS LOCATED IN SUSPENDED CEILING TILE AREAS

SHALL BE LOCATED IN THE CENTER OF THE CEILING TILE.

S ANNULAR SPACE AT PIPE AND OTHER SIMILAR PENETRATION OF FIRE RATED

ASSEMBLIES SHALL BE FIRE STOPPED. REFER TO SPECIFICATIONS FOR FIRE

STOPPING. REFER TO ARCHITECTURAL DRAWINGS FOR CONSTRUCTION, LAYOUT

AND FIRE RATING OF FLOORS, WALLS, PARTITIONS AND OTHER BUILDING

ELEMENTS.

T A FLOW TEST IS REQUIRED. REFER TO SPECIFICATION SECTION 21 13 13 FOR

FLOW TEST INFORMATION.

U ALL SPRINKLER ZONES SHALL MATCH SMOKE COMPARTMENTS.

V REFER TO ARCHITECTURAL DRAWINGS FOR INFORMATION ON SMOKE

COMPARTMENTS, SMOKE PARTITIONS AND FIRE BARRIERS.

W PHASING: REFER TO ARCHITECTURAL DRAWINGS FOR AN OUTLINE OF PROJECT

PHASING. ADDITIONAL NOTES DESCRIBING PHASING DETAILS MAY BE INCLUDED

THROUGHOUT THIS DRAWING SET. INCLUDE ALL LABOR AND MATERIAL TO

ACCOMMODATE PHASING.

X BID ITEMS: REFER TO ARCHITECTURAL DRAWING AND SPECIFICATION SECTION

01 00 00 FOR AN OUTLINE OF BID ITEMS. ADDITIONAL NOTES DESCRIBING BID

ITEM DETAILS MAY BE INCLUDED THROUGHOUT THIS DRAWING SET.

Y SPRINKLER SYSTEM PIPING AND FITTINGS SHALL BE IN ACCORDANCE WITH

NFPA 13.

1 PIPING SIZES 2" AND SMALLER SHALL BE BLACK STEEL SCHEDULE 40

WITH THREADED END CONNECTIONS.

2 PIPING SIZES 2.5" AND LARGER SHALL BE BLACK STEEL SCHEDULE 10

WITH GROOVED CONNECTIONS. GROOVES IN SCHEDULE 10 PIPING SHALL BE

ROLLED GROOVED ONLY.

FIRE SUPPRESSION DESIGN NOTES

LOCATION: EDWARD HINES, JR VA HOSPITAL

5000 S. 5th Ave., Hines, IL 60141

BLDG 20 (S. 1ST AVE & CEMARK)

STATIC PRESSURE: 72 PSI

RESIDUAL PRESSURE: 60 PSI

FLOW: 830 GPM

DATE: 12/16/2021

NOTE: PERFORM HYDRAULIC CALCULATIONS UTILIZING THE BASIS OF DESIGN FLOW

TEST DATA PROVIDED TO BID THE FIRE SUPPRESSION SPRINKLER SYSTEM. UPON

AWARD OF THE PROJECT, A HYDRANT FLOW TEST ALONG WITH CORRESPONDING

HYDRAULIC CALCULATIONS SHALL BE PERFORMED TO VERIFY ADEQUATE PRESSURE

AND FLOW.

BASIS OF DESIGN FLOW TEST DATA

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/1

/2

:5

:0

A

M

F001

FIRE SUPPRESSION ABBREVIATIONS,

LEGEND & DRAWING INDEX

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

DRAWING INDEX - FIRE SUPPRESSION

SHEET NUMBER SHEET NAME

F001 FIRE SUPPRESSION ABBREVIATIONS, LEGEND & DRAWING INDEX

FX101 FIRE SUPPRESSION BASEMENT & FIRST FLOOR PLANS

FX102 FIRE SUPPRESSION SECOND FLOOR PLAN

BFP

S

C D E F G H I J K L M N O P

OH

2 2

OH

EXISTING FIRE

SERVICE ENTRANCE

OH

OH

OH

OH

FDC

LOBBY

E1-A

ELEVATOR

ELEVATOR

EQUIPMENT

UNISEX

RESTROOM

UNISEX

RESTROOM

MECHANICAL

BREAK (6)

C1

CORRIDOR

OFFICE (1)

OFFICE (1)

OFFICE (1)

TR

OFFICE (1)

OFFICE (1)

S2-A

STAIR

ELECTRICAL

CLOSET

SS

SHELL

SPACE

ELECTRICAL

C1

CORRIDOR

A. REFER TO SHEET F001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

B. EXISTING CORRIDORS AND/ OR ROOMS TO REMAIN OPERATIONAL AT ALL TIMES DURING

BUSINESS HOURS. AUTOMATIC SPRINKLER SYSTEM(S) SHALL BE MAINTAINED IN FULLY

OPERATIONAL CONDITION (PER NFPA 241, SPRINKLER SYSTEMS WILL BE OPERATIONAL,

BUT IMPAIRED WHILE CEILINGS ARE REMOVED). SPRINKLER SYSTEM MAY BE TAKEN

OFF-LINE FOR UP TO 8 HOURS, AS REQUIRED, TO MAKE MODIFICATIONS/ CONNECTIONS

TO EXISTING SYSTEM.

GENERAL NOTES

N O P

2 2

OH

BASEMENT

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/1

/2

:5

:0

A

M

FX101

FIRE SUPPRESSION BASEMENT & FIRST

FLOOR PLANS

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

FIRST FLOOR PLAN - FIRE SUPPRESSION

PLAN NOTES

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.

2. LIMITS OF RENOVATED AREA REQUIRING EXISTING SPRINKLER SYSTEM MODIFICATIONS.

MODIFICATIONS INCLUDE, BUT ARE NOT LIMITED TO, REPLACING ALL SPRINKLERS,

PIPE BRANCHES AND MAINS TO CONFORM TO NEW ARCHITECTURAL LAYOUTS WHERE

NECESSARY.

3. ONLY SPRINKLER PIPING SERVING ROOM'S SPRINKLER(S) SHALL BE ALLOWED ABOVE

THIS ROOM.

4. OPEN TO DECK ABOVE.

5. PROVIDE SUPERVISED VALVE TO ISOLATE SPRINKLERS SERVING ELEVATOR

EQUIPMENT ROOM.

6. PROVIDE STANDARD RESPONSE, INTERMEDIATE TEMPERATURE SPRINKLERS IN THE

ELEVATOR MACHINE ROOM.

7. PROVIDE SIDEWALL SPRINKLER IN THE ELEVATOR PIT LOCATED NO MORE THAN

2 FEET ABOVE THE PIT.

KEYPLAN

N

1/8" = 1'-0"

BASEMENT PLAN - FIRE SUPPRESSION

SS

C D E F G H I J K L M N O P

OH

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

BREAK

ROOM

CLASSROOM

(17)

CLASSROOM

(17)

MECHANICAL

ROOM

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

C4

CORRIDOR

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

S1-B

STAIR

S2-B

STAIR

C3

CORRIDOR

CERNER

AND

COMMAND

CENTER

(30)

ELEVATOR

LOBBY

S3-B

STAIR

HAC

WOMEN'S

RESTROOM

MEN'S

RESTROOM

TR

C2

CORRIDOR

CLASSROOM

(17)

VENDING

E1-B

ELEVATOR

OH

OH

OH

ELEC.

OH

PLANNING

AND PREP

C5

CORRIDOR

C5

CORRIDOR

C5

CORRIDOR

CLASSROOM

(17)

5 5

C2

CORRIDOR

C3

CORRIDOR

5 5

E2

FREIGHT

ELEVATOR

227A

ELEV.

SERVICE

CONFERENCE

ROOM

A. REFER TO SHEET F001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

B. EXISTING CORRIDORS AND/ OR ROOMS TO REMAIN OPERATIONAL AT ALL TIMES DURING

BUSINESS HOURS. AUTOMATIC SPRINKLER SYSTEM(S) SHALL BE MAINTAINED IN FULLY

OPERATIONAL CONDITION (PER NFPA 241, SPRINKLER SYSTEMS WILL BE OPERATIONAL,

BUT IMPAIRED WHILE CEILINGS ARE REMOVED). SPRINKLER SYSTEM MAY BE TAKEN

OFF-LINE FOR UP TO 8 HOURS, AS REQUIRED, TO MAKE MODIFICATIONS/ CONNECTIONS

TO EXISTING SYSTEM.

GENERAL NOTES

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/1

/2

:5

:1

A

M

FX102

FIRE SUPPRESSION SECOND FLOOR

PLAN

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

SECOND FLOOR PLAN - FIRE SUPPRESSION

PLAN NOTES

1. LIMITS OF RENOVATED AREA REQUIRING EXISTING SPRINKLER SYSTEM MODIFICATIONS.

MODIFICATIONS INCLUDE, REPLACING ALL SPRINKLERS, PIPE BRANCHES, HANGERS

AND MAINSTO CONFORM TO NEW ARCHITECTURAL LAYOUT.

NOTE: FLOOR HEIGHT IS LIMITED. CLOSE COORDINATION WITH OTHER DIVISIONS IS

CRITICAL.

2. ONLY SPRINKLER PIPING SERVING ROOM'S SPRINKLER(S) SHALL BE ALLOWED ABOVE

THIS ROOM.

3. PROVIDE SUPERVISED VALVE TO ISOLATE SPRINKLERS SERVING ELEVATOR

EQUIPMENT ROOM.

4. PROVIDE STANDARD RESPONSE, INTERMEDIATE TEMPERATURE SPRINKLERS IN THE

ELEVATOR MACHINE ROOM.

5. OPEN TO DECK ABOVE.

KEYPLAN

NOTE: ALL SYMBOLS AND ABBREVIATIONS ARE SUBJECT TO MODIFICATIONS ON OTHER DRAWINGS. ADDITIONALLY, ALL SYMBOLS OR ABBREVIATIONS MIGHT NOT NECESSARILY BE USED ON THIS PROJECT.

A1

P1 P1OR

A1

OH

P2

B

P2

GENERAL FLOOR PLAN NOTES

RISER OR STACK NUMBER

DETAIL: B = DETAIL DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

FIRE SUPPRESSION HAZARD CLASSIFICATION AND

HAZARD CLASSIFICATION GROUP

SECTION: 1 = SECTION DESIGNATION

P2 = SHEET WHERE DETAIL IS LOCATED

EQUIPMENT REFERENCE. LETTER DESIGNATION

VARIES. REFER TO SCHEDULES.

EQUIPMENT, DEVICE, OR PLUMBING FIXTURE MARK.

LETTER DESIGNATIONS REFER TO SCHEDULES.

CONNECT TO EXISTING

PLAN NOTE. APPLIES ONLY TO THE SHEET WHICH

IT IS SHOWN UNLESS NOTED OTHERWISE.

DETAIL NOTE. APPLIES ONLY TO THE ASSOCIATED DETAIL.

"UP TO" SYMBOL (ITEM ON FLOOR ABOVE)

PIPING DESIGNATIONS

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

EXISTING PIPE TO REMAIN

EXISTING PIPE TO BE REMOVED

HOT WATER PIPE (140 DEGS. F.)

HOT WATER RETURN PIPE (140 DEGS. F.)

HOT WATER RETURN PIPE (180 DEGS. F.)

140R

180R

EXPANSION JOINT

WATER METERM

PIPING SYMBOLS

BOTTOM CONNECTION (45°)

BRANCH TEE CONNECTION (NOTE:

BULLHEAD TEE'S ARE NOT PERMITTED)

DIRECTION OF PITCH

DROP

ELBOW DOWN

ELBOW UP

FLOW DIRECTION DESIGNATION

PUMP

RISE

TOP CONNECTION (45°)

TOP CONNECTION (90°)

BOTTOM CONNECTION (90°)

D

R

PIPE RISER

HOT WATER PIPE (180 DEGS. F.)

ARGON PIPE

COMPRESSED AIR PIPE

GARAGE DRAINAGE PIPE

HYDROGEN PIPE

HELIUM PIPE

KITCHEN WASTE PIPE

LABORATORY COMPRESSED AIR PIPE

LABORATORY VENT PIPE

LABORATORY VACUUM PIPE

LABORATORY WASTE PIPE

NON-POTABLE

(OVERFLOW) SECONDARY STORM DRAINAGE PIPE

PUMP DISCHARGE PIPE

PURE WATER PIPE

SANITARY DRAINAGE PIPE

SOFT COLD WATER

STORM DRAINAGE PIPE

TRAP PRIMER DISCHARGE PIPE

TEMPERED WATER PIPE

SANITARY SEWER VENT

WATER SERVICE

LV

AR

CA

GD

H2

HE

IV

IW

LA

LV

LW

NPW

OD

PD

PW

SAN

SCW

STM

TP

TW

V

WS

INDIRECT VENT PIPE

INDIRECT WASTE PIPE

K

ACID VENT PIPEAV

ACID WASTE PIPEAW

BC

TC

COMBINATION FIRE SUPPRESSION &

DOMESTIC WATER SERVICE

CWS

FLEX PIPING

VALVES AND FITTINGS

T

P

FOB

FOT

CONCENTRIC PIPE REDUCER

ECCENTRIC PIPE REDUCER

GAUGE - PRESSURE

GAUGE - TEMPERATURE OR THERMOMETER

UNION

CLEANOUT

STRAINER

STRAINER - WITH A BLOW DOWN VALVE AND HOSE

CONNECTION

VALVE - DRAIN WITH HOSE END CONNECTION

VALVE - PRESSURE REGULATING

VALVE - SAFETY RELIEF. PIPE DISCHARGE AIR

GAPPED TO FLOOR DRAIN UNLESS NOTED

OTHERWISE.

PLUG - PRESSURE AND TEMPERATURE TEST

TRAP PRIMER

GAUGE - VACUUM WITH STOP

CLEANOUT - TO GRADE OR FINISHED FLOOR

END CAP

MIXING FAUCET

PLUG

HOSE BIB

WALL HYDRANT

VALVE - PLUG

VALVE - SHUTOFF AND BOX

VALVE - SHUTOFF ON RISER

V

VB

TP

CO

VALVE - SOLENOID

S

P/T VALVE - PRESSURE AND TEMPERATURE SAFETY

RELIEF. PIPE DISCHARGE AIR GAPPED TO

FLOOR DRAIN UNLESS NOTED OTHERWISE.

VALVE - CHECK

VALVE - SHUTOFF: BALL, GATE, BUTTERFLY VALVE

(REFER TO SPECIFICATIONS FOR REQUIRED TYPE

BASED ON APPLICATIONS)

AUTOMATIC FLOW CONTROLLER WITH P/T PLUG IN

AND OUT

VALVE - COMBINATION SHUTOFF AND

BALANCING (REFER TO SPECIFICATIONS FOR

REQUIRED TYPE BASED ON APPLICATIONS)

ABBREVIATIONS

AAP - AREA ALARM PANEL (MEDICAL GAS)

AC - AIR COMPRESSOR OR AIR CONDITIONER

ACC - ACCESS

ACCU - AIR COOLED CONDENSING UNIT

AD - ACCESS DOOR OR AREA DRAIN

ADB - ACID DILUTION BASIN

ADJ - ADJUSTABLE

AFF - ABOVE FINISHED FLOOR

AFG - ABOVE FINISHED GRADE

ALT - ALTERNATE

AP - ACCESS PANEL

APPROX - APPROXIMATE

AR - AIR RECEIVER OR ARGON

ARCH - ARCHITECT OR ARCHITECTURAL

ASSY - ASSEMBLY

AV - ACID VENT

AW - ACID WASTE

BDD - BACK DRAFT DAMPER

BFP - BACKFLOW PREVENTER

BLDG - BUILDING

BOB - BOTTOM OF BEAM

BOD - BOTTOM OF DUCT

BOE - BOTTOM OF EQUIPMENT

BOF - BOTTOM OF FOOTING

BOG - BOTTOM OF GRILLE

BOP - BOTTOM OF PIPE

BOT - BOTTOM

BT - BATHTUB

BTU - BRITISH THERMAL UNIT

BTUH - BRITISH THERMAL UNIT PER HOUR

BTWN - BETWEEN

CA - COMPRESSED AIR

CB - CATCH BASIN

CBD - COUNTER BALANCED BACKDRAFT DAMPER

CFCI - CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CFM - CUBIC FEET PER MINUTE

CHS - CHILLED WATER SUPPLY

CHR - CHILLED WATER RETURN

CI - CAST IRON

CK - CLINICAL SINK

CLG - CEILING

CMU - CONCRETE MASONRY UNIT

CO - CLEAN OUT

CO2 - MEDICAL CARBON DIOXIDE

CONN - CONNECT OR CONNECTION

CONTR - CONTRACTOR

COR - CONTRACTING OFFICER'S REPRESENTATIVE

CORR - CORRIDOR

CS - CLINICAL SINK OR COLD SOFT WATER

CTR - CENTER

CU - COPPER

CW - COLD WATER

CWS - COMBINATION WATER SERVICE

OR CONDENSER WATER SUPPLY

CWR - CONDENSER WATER RETURN

D - DEPTH OR DRAIN LINE

DD - DECK DRAIN

DCW - DOMESTIC COLD WATER

DET - DETAIL

DF - DRINKING FOUNTAIN OR WATER COOLER

OR DIESEL FUEL

DFU - DRAINAGE FIXTURE UNIT

DHW - DOMESTIC HOT WATER

DHWR - DOMESTIC HOT WATER RETURN

DI - DEIONIZED WATER

DIA - DIAMETER

DIM - DIMENSION

DN - DOWN

DS - DOWN SPOUT OR SPRINKLER (DRY)

DT - PERFORATED DRAIN TILE

DWG - DRAWING

EA - EACH

EC - ELECTRICAL (DIVISION 26)

EEW - EMERGENCY EYE WASH

EJ - EXPANSION JOINT

ELEC - ELECTRICAL

ELEV - ELEVATOR

EQ - EQUAL

EQUIP - EQUIPMENT

ET - EXPANSION TANK

ETR - EXISTING TO REMAIN

ES - EMERGENCY SHOWER

EQS - EQUIPMENT SUPPLIER

EWC - ELECTRICAL WATER COOLER

EXH - EXHAUST AIR

EXP - EXPANSION

EXT - EXTERIOR

EX - EXISTING

F - FIRE SUPPRESSION (STANDPIPE/SPRINKLER

MAIN)

FCE - FIRE CONTROL EQUIPMENT

FCO - FLOOR CLEANOUT

FD - FLOOR DRAIN

FDC - FIRE DEPARTMENT CONNECTION

FDV - FIRE DEPARTMENT VALVE

FF - FINISHED FLOOR ELEVATION

FHC - FIRE HOSE CABINET

FLR - FLOOR

FM - FORCE MAIN

FOB - FLAT ON BOTTOM

FOF - FUEL OIL FLOW

FOG - FUEL OIL GAUGE

FOR - FUEL OIL RETURN

FOS - FUEL OIL SUPPLY

FOT - FLAT ON TOP

FPM - FEET PER MINUTE

FR - FIRE RISER

FS - FLOOR SINK OR FIRE SERVICE

FSC - FIRE SUPPRESSION (DIVISION 21)

FT - FEET

FTG - FOOTING

G - GAS OR NATURAL GAS

GA - GAUGE

GAL - GALLON

GALV - GALVANIZED

GC - GENERAL TRADES

GD - GARAGE DRAINAGE

GPM - GALLONS PER MINUTE

GS - GAS SERVICE

GW - GREASE WASTE

H2 - HYDROGEN

HB - HOSE BIBB

HC - HVAC (DIVISION 23)

HD - HUB DRAIN

HE - HELIUM

HG - REFRIGERANT HOT GAS

HP - HORSEPOWER OR HIGH POINT

HPC - HIGH PRESSURE CONDENSATE RETURN

HPS - HIGH PRESSURE STEAM SUPPLY

HPW - HIGH PURITY WATER

HPWR - HIGH PURITY WATER RETURN

HR - HOSE REEL

HT - HEAT TRACE

HTR - HEATER

HVAC - HEATING, VENTILATING, AND AIR

CONDITIONING

HW - HOT WATER

HWR - HEATING HOT WATER RETURN

HWS - HEATING HOT WATER SUPPLY

IA - MEDICAL INSTRUMENT AIR

ID - INSIDE DIAMETER

INV - INVERT ELEVATION

IN - INCHES

IV - INDIRECT VENT

IW - INDIRECT WASTE

JS - JANITOR SINK

K - KITCHEN WASTE

KEC - KITCHEN EQUIPMENT

L - LENGTH

LA - LABORATORY COMPRESSED AIR

LAV - LAVATORY

LBS - POUNDS

LCW - LABORATORY COLD WATER

LEC - LABORATORY EQUIPMENT

LHW - LABORATORY HOT WATER

LHWR - LABORATORY HOT WATER RETURN

LPC - LOW PRESSURE CONDENSATE RETURN

LPS - LOW PRESSURE STEAM SUPPLY

LV - LABORATORY VACUUM OR LABORATORY

VENT

LW - LABORATORY WASTE

MA - MEDICAL COMPRESSED AIR

MAP - MASTER ALARM PANEL (MEDICAL GAS)

MAX - MAXIMUM

MB - MOP BASIN

MC - MECHANICAL (DIVISION 23)

MEZZ - MEZZANINE

MFR - MANUFACTURER

MH - MANHOLE

MIN - MINIMUM OR MINUTE

MISC - MISCELLANEOUS

MTD - MOUNTED

MTG - MOUNTING

MPC - MEDIUM PRESSURE CONDENSATE RETURN

MPS - MEDIUM PRESSURE STEAM SUPPLY

MU - WATER MAKE-UP

MV - MEDICAL SURGICAL VACUUM

N2 - MEDICAL NITROGEN

N/C - NORMALLY CLOSED

NG - GASOLINE (NON-LEAD)

NIC - NOT IN CONTRACT

N/O - NORMALLY OPEN

NO - MEDICAL NITROUS OXIDE

NOM - NOMINAL

NPW - NON-POTABLE WATER

NPT - NATIONAL PIPE THREAD

NTS - NOT TO SCALE

O2 - MEDICAL OXYGEN

OA - OUTDOOR AIR

OD - OUTSIDE DIAMETER OR OVERFLOW

DRAIN

OFCI - OWNER FURNISHED CONTRACTOR

INSTALLED

OFOI - OWNER FURNISHED OWNER INSTALLED

P - PROPANE GAS

PC - PLUMBING (DIVISION 22) OR PUMPED

CONDENSATE RETURN

PD - PUMP DISCHARGE OR PARAPET DRAIN

PIV - POST INDICATOR VALVE

PLBG - PLUMBING

PS - PRE-ACTION/DELUGE SPRINKLER

PRESS - PRESSURE

PRV - PRESSURE REGULATING VALVE

PSF - POUNDS PER SQUARE FOOT

PSI - POUNDS PER SQUARE INCH

PSV - PRESSURE SUSTAINING VALVE

PSIG - POUNDS PER SQUARE INCH GAUGE

PW - PURE WATER

RA - RETURN AIR

RAD - RADIUS

RCP - REINFORCED CONCRETE PIPE

RD - ROOF DRAIN

REC - RECESSED

REQD - REQUIRED

RI - ROUGH IN

RL - REFRIGERANT LIQUID

ROS - REVERSE OSMOSIS WATER SUPPLY

ROR - REVERSE OSMOSIS WATER RETURN

RPM - REVOLUTIONS PER MINUTE

RS - REFRIGERANT SUCTION

RV - RELIEF VALVE

S - SPRINKLER (WET)

SA - SHOCK ARRESTOR OR SUPPLY AIR

SAN - SANITARY OR SANITARY DRAIN

SCH - SCHEDULE

SCW - SOFT COLD WATER

SD - SPRINKLER DRAIN OR SUBSOIL DRAIN

SH - SHOWER

SHT - SHEET

SK - SINK

SPEC - SPECIFICATIONS

SQ - SQUARE

SR - SUPPLY RISER

SS - SANITARY STACK (SOIL OR WASTE) OR

STAINLESS STEEL

STD - STANDARD

STM - STORM OR STORM DRAINAGE

STRUC - STRUCTURAL OR STRUCTURE

SUC - SITE UTILITY CONTRACTOR

T - FUEL TANK VENT

TD - TRENCH DRAIN

TEMP - TEMPERATURE

TOB - TOP OF BEAM

TOD - TOP OF DUCT

TOE - TOP OF EQUIPMENT

TOF - TOP OF FOOTING

TOJ - TOP OF JOIST

TOP - TOP OF PIPE

TOS - TOP OF SLAB OR TOP OF STEEL

TF - TRAP FILLER

TP - TRAP PRIMER OR TRAP PRIMER

DISCHARGE

TW - TEMPERED WATER

TYP - TYPICAL

UR - URINAL

UNO - UNLESS NOTED OTHERWISE

V - VENT OR SANITARY SEWER VENT

VAC - VACUUM

VC - VACUUM CLEANING

VCV - VACUUM CLEANING VALVE

VE - VACUUM EXHAUST

VEL - VELOCITY

VIB - VALVE IN BOX

VOL - VOLUME

VP - VACUUM PUMP

VS - VENT STACK

VTR - VENT THROUGH ROOF

VR - VENT RISER

W/ - WITH

W/O - WITHOUT

W - WASTE

WAGD - WASTE ANESTHESIA GAS DISPOSAL

WC - WATER CLOSET

WCO - WALL CLEANOUT

WH - WALL HYDRANT OR WATER HEATER

WIV - WALL INDICATOR VALVE

WS - WATER SERVICE

WV - WATER VALVE

YCO - YARD CLEANOUT

ZVC - ZONE VALVE CABINET

GENERAL NOTES

A ALL PIPING IS ABOVE THE CEILING (AT THE UNDERSIDE OF STRUCTURE IN

EXPOSED STRUCTURE AREAS), UNLESS OTHERWISE NOTED.

B REFER TO SCHEDULES, DETAILS AND DIAGRAMS FOR PIPING, PIPE SIZES AND

PIPELINE DEVICES NOT INDICATED ON THE FLOOR PLAN.

C ABOVE CEILING UTILITY SPACE IS LIMITED. COORDINATION WITH ALL TRADES IS

CRITICAL, PRIOR TO INSTALLATION OF ANY WORK.

D LOCATIONS AND SIZES OF EXISTING PIPING HAVE BEEN DETERMINED FROM A

REVIEW OF EXISTING DRAWINGS AND/OR SITE INSPECTION, WHERE POSSIBLE.

FIELD VERIFICATION OF EXACT LOCATIONS, ELEVATIONS, INVERTS, SIZES,

DIRECTION OF FLOW, ETC. SHALL BE REQUIRED PRIOR TO BEGINNING NEW

WORK.

E ALL PIPING SHALL BE REMOVED BACK TO WITHIN TWO PIPE DIAMETERS OF

ACTIVE MAINS AND CAPPED, OR REMOVED BACK TO POINTS OF CONNECTION

OF NEW WORK. INACCESSIBLE PIPING, WHERE SO NOTED, TO BE ABANDONED

SHALL BE DISCONNECTED FROM ACTIVE MAINS AND CAPPED OR PLUGGED IN

CONCEALED LOCATIONS.

F NEW CONNECTIONS TO EXISTING PIPING SHALL BE WITH THE SAME SIZE AS THE

EXISTING PIPING UNLESS OTHERWISE NOTED.

G ALL REMOVED MATERIAL AND EQUIPMENT SO DESIGNATED BY THE OWNER,

SHALL BE TURNED OVER AND PLACED WHERE DIRECTED. ALL MATERIAL AND

EQUIPMENT, WHICH THE OWNER DOES NOT WISH TO RETAIN, SHALL BECOME

THE PROPERTY OF THE CONTRACTOR RESPONSIBLE FOR THE REMOVAL.

H ANY RENOVATION WORK REQUIRED "OUTSIDE" OF THE BOUNDARIES/ EXTENTS

OF A SPECIFIC PHASE OF WORK OR TEMPORARY CONSTRUCTION WALLS

SHALL BE BID AS "NIGHT WORK" AND SHALL BE AS DIRECTED BY THE COR.

I ALL CORE DRILLS AND PIPE EXTENSIONS THRU THE EXISTING STRUCTURAL

FLOOR SLAB OR STRUCTURAL WALL SHALL BE X-RAYED TO DETERMINE THE

EXACT LOCATION OF THE REBAR IN THE STRUCTURAL SLAB. DO NOT CUT

THE LOWER (BOTTOM REBARS) IN THE STRUCTURAL FLOOR SLAB.

J WORKING ON EXISTING FLOORS WITH NO/ LIMITED ARCHITECTURAL SCOPE, THE

CONTRACTOR SHALL PROVIDE ALL REQUIRED FLOOR/ WALL PROTECTION (AS

REQUIRED) AND REPLACE ANY DAMAGED CEILING TILES WITH NEW. RETURN

AREA BACK TO ORIGINAL CONDITION UPON COMPLETION OF WORK.

K REFER TO ARCHITECTURAL FIRE RATED PARTITION PLAN(S) FOR LOCATIONS

AND FIRE RATINGS OF NEW AND EXISTING WALL ASSEMBLIES. ALL

PENETRATIONS THROUGH FIRE RATED ASSEMBLIES SHALL BE PROTECTED

AND/OR FIRE STOPPED AS REQUIRED TO MAINTAIN FIRE RATINGS INDICATED.

COORDINATE WITH ALL TRADES TO ENSURE FIRE RATED PENETRATION

REQUIREMENTS AND DETAILS ARE MET.

L ANNULAR SPACE OF ALL PIPE & OTHER SIMILAR PENETRATIONS OF FIRE RATED

ASSEMBLIES SHALL BE FIRE STOPPED. IN ADDITION, PENETRATIONS THROUGH

0-HOUR RATED WALLS & FLOOR SHALL BE SEALED TO RETARD THE PASSAGE

OF SMOKE.

M DOMESTIC WATER PIPING SYSTEM IN THE RENOVATED AREA SHALL BE

DISINFECTED AND TESTED IN ITS ENTIRETY. DISINFECTION AND TESTING

PROCEDURES SHALL FOLLOW VA WATER SAFETY PLAN, OTHER VA

DESIGN MANUALS, SPECIFICATIONS, AND LOCAL REQUIREMENTS.

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:2

P M

P001

PLUMBING ABBREVIATIONS, LEGEND &

DRAWING INDEX

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

DRAWING INDEX - PLUMBING

SHEET NUMBER SHEET NAME

P001 PLUMBING ABBREVIATIONS, LEGEND & DRAWING INDEX

PD100 PLUMBING BASEMENT PLAN - REMOVALS

PD101 PLUMBING FIRST FLOOR PLAN - REMOVALS

PD102 PLUMBING SECOND FLOOR PLAN - REMOVALS

PL100 PLUMBING BASEMENT PLAN - NEW WORK

PL101 PLUMBING FIRST FLOOR PLAN - NEW WORK

PL102 PLUMBING SECOND FLOOR PLAN - NEW WORK

P401 PLUMBING ENLARGED PLANS

P601 PLUMBING SCHEDULES & DETAILS

P901 PLUMBING SOIL, WASTE & VENT DIAGRAM

P902 PLUMBING SOIL, WASTE & VENT DIAGRAM

P903 PLUMBING DOMESTIC WATER DIAGRAM

P904 PLUMBING DOMESTIC WATER DIAGRAM

UP6" F

A

PD100

UP3" DCW

3"

3"

1.5"

6"

6"

2"

SAN

S A

N

S A

N

SP2

FD

CO

WC

LAV

WC

SH/FD

SAN SAN

4" S

AN

DN6" SAN 1

UP4" V 1

4"

PD

SLAB ON GRADE

SLAB ON GRADE

SLAB ON GRADE

BSMT

SLAB ON GRADE

12" SAN

SANITARY MH #2756

4" SAN

12" SAN

11 1

WV

PIV

WV

UP4" PD

Level 1 100' - 0"

Basement 87' - 9"

4" - V

CO

BASIN 1

4" - PD

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:3

P M

PD100

PLUMBING BASEMENT PLAN -

REMOVALS

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

BASEMENT PLAN - REMOVALS

PLAN NOTES

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS

INDICATED) TO REMAIN.

2. REMOVE ALL EXTRANEOUS SANITARY DRAIN AND VENT PIPING BACK TO

POINT OF NEW CONNECTION OR BACK TO ACTIVE MAIN AND CAP. CAP

PIPING IN WALLS WHERE WALLS ARE TO REMAIN OR ABOVE CEILING OR

BELOW FLOOR SLAB WHERE WALLS ARE TO BE REMOVED. NO PIPE

STUBS SHALL REMAIN VISIBLE IN FINISHED AREAS.

3. REMOVE DUPLEX SUMP PUMP, MOTORS, VALVES AND CONTROLLERS.

REMOVE SUMP PIPING BACK TO POINT OF NEW CONNECTION.

THOROUGHLY CLEAN SUMP BASIN. (BASIN TO REMAIN). REFER TO

DETAIL A, THIS SHEET.

4. CAREFUL EXCAVATION IS REQUIRED IN THIS LOCATION. VERIFY EXACT

LOCATION, INVERTS, SIZES, CONNECTIONS AND DIRECTION OF SANITARY

PIPING PRIOR TO ANY DEMOLITION. EXISTING CONDITIONS ARE

UNKNOWN.

KEYPLAN

SCALE: 1/4" = 1'-0"

SUMP PUMP - SP2

A

GENERAL NOTES:

A. REFER TO P001 FOR ABBREVIATIONS, LEGEND AND DRAWING INDEX.

B. MAINTAIN AND RESTORE, IF INTERRUPTED, THE DOMESTIC WATER SUPPLY

AND SANITARY & VENT SYSTEMS TO THE EXISTING PLUMBING FIXTURES

LOCATED IN UNDISTURBED AREA.

BFP

C D E F G H I J K L M N O P

EXISTING FIRE/ WATER

SERVICE ENTRANCE

LAV

WC

FD SH

LAV

WC 2

E-85

2 VENT STACK

FDC

VENT STACK

& VTR

DWH1

3"

FD

4"

PD

DN4" PD

HB

HB

SK 2

STORAGE ANNEX NIC

1DWH

C D E F G H I J K L M N O P

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:4

P M

PD101

PLUMBING FIRST FLOOR PLAN -

REMOVALS

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

FIRST FLOOR PLAN - REMOVALS

PLAN NOTES

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.

2. REMOVE EXISTING FIXTURE OR ITEM OF EQUIPMENT (TYPE AS INDICATED) AND ALL

EXTRANEOUS DOMESTIC WATER PIPING BACK TO POINT OF NEW CONNECTION OR

WITH-IN TWO (2) PIPE DIAMETERS OF ACTIVE MAIN. REMOVE ALL EXTRANEOUS

SANITARY DRAIN AND VENT PIPING BACK TO POINT OF NEW CONNECTION OR BACK

TO ACTIVE MAIN AND CAP. CAP PIPING IN WALLS WHERE WALLS ARE TO REMAIN OR

ABOVE CEILING OR BELOW FLOOR SLAB WHERE WALLS ARE TO BE REMOVED. NO

PIPE STUBS SHALL REMAIN VISIBLE IN FINISHED AREAS.

3. REMOVE EXISTING FLOOR DRAIN GRATE AND STRAINER, PLUG DRAIN OUTLET, AND

FILL DRAIN WITH CONCRETE FLUSH WITH EXISTING FLOOR SLAB. REMOVE

EXISTING PIPING SERVING FLOOR DRAIN BACK TO ACTIVE MAIN AND CAP OR POINT

OF NEW CONNECTION.

4. REMOVE ENTIRE EXISTING HALON SYSTEM AND ALL ASSOCIATED PIPING.

5. REMOVE ALL PLUMBING PIPING, LINE DEVICES AND ACCESSORIES REMAINING IN

THIS AREA UNLESS OTHERWISE NOTED TO REMAIN.

REMOVE EXISTING DOMESTIC WATER PIPING BACK TO POINT OF NEW CONNECTION

OR WITH-IN TWO (2) PIPE DIAMETERS OF ACTIVE MAIN AND CAP.

REMOVE ALL EXTRANEOUS SANITARY DRAIN AND VENT PIPING BACK TO POINT OF

NEW CONNECTION OR BACK TO ACTIVE MAIN AND CAP.

NO PIPE STUBS SHALL REMAIN VISIBLE IN FINISHED AREAS.

REMOVE ALL EXISTING PLUMBING PIPING PROTRUDING THRU FLOOR/ DECK TO

FLUSH WITH FLOOR/ DECK. FILL WITH CONCRETE TO FLUSH WITH EXISTING

FLOOR/ DECK .

6. EXISTING VEEDER ROOT (E-85) FUELING MANAGEMENT SYSTEM TO REMAIN.

7. CAREFUL EXCAVATION IS REQUIRED IN THIS LOCATION. VERIFY EXACT LOCATION,

INVERTS, SIZES, CONNECTIONS AND DIRECTION OF SANITARY PIPING PRIOR TO

DEMOLITION.

KEYPLAN

GENERAL NOTES:

A. REFER TO P001 FOR ABBREVIATIONS, LEGEND AND DRAWING INDEX.

B. MAINTAIN AND RESTORE, IF INTERRUPTED, THE DOMESTIC WATER SUPPLY

AND SANITARY & VENT SYSTEMS TO THE EXISTING PLUMBING FIXTURES LOCATED

IN UNDISTURBED AREA.

VTR

VENT STACK

VTR

VENT STACK

& VTR

VTR

3 1

2 VENT STACK

SK

A. REFER TO SHEET P001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

GENERAL NOTES

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:4

P M

PD102

PLUMBING SECOND FLOOR PLAN -

REMOVALS

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

SECOND FLOOR PLAN - REMOVALS

PLAN NOTES

KEYPLAN

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.

2. REMOVE EXISTING VENT STACK AND VENT THRU ROOF. PATCH TO MATCH EXISTING.

SEAL WATER-TIGHT.

3. REMOVE EXISTING FIXTURE OR ITEM OF EQUIPMENT (TYPE AS INDICATED) AND ALL

EXTRANEOUS DOMESTIC WATER PIPING BACK TO POINT OF NEW CONNECTION OR

WITH-IN TWO (2) PIPE DIAMETERS OF ACTIVE MAIN. REMOVE ALL EXTRANEOUS

SANITARY DRAIN AND VENT PIPING BACK TO POINT OF NEW CONNECTION OR BACK

TO ACTIVE MAIN AND CAP. CAP PIPING IN WALLS WHERE WALLS ARE TO REMAIN OR

ABOVE CEILING OR BELOW FLOOR SLAB WHERE WALLS ARE TO BE REMOVED. NO

PIPE STUBS SHALL REMAIN VISIBLE IN FINISHED AREAS.

4. REMOVE ALL PLUMBING PIPING, LINE DEVICES AND ACCESSORIES REMAINING IN

THIS AREA UNLESS OTHERWISE NOTED TO REMAIN.

REMOVE EXISTING DOMESTIC WATER PIPING BACK TO POINT OF NEW CONNECTION

OR WITH-IN TWO (2) PIPE DIAMETERS OF ACTIVE MAIN AND CAP.

REMOVE ALL EXTRANEOUS SANITARY DRAIN AND VENT PIPING BACK TO POINT OF

NEW CONNECTION OR BACK TO ACTIVE MAIN AND CAP.

NO PIPE STUBS SHALL REMAIN VISIBLE IN FINISHED AREAS.

REMOVE ALL EXISTING PLUMBING PIPING PROTRUDING THRU FLOOR/ DECK TO

FLUSH WITH FLOOR/ DECK. FILL WITH CONCRETE TO FLUSH WITH EXISTING

FLOOR/ DECK.

B. REMOVE ALL EXISTING PLUMBING PIPING PROTRUDING THRU FLOOR TO FLUSH

WITH FLOOR/ DECK. PROVIDE BACKING MATERIAL AND FILL WITH CONCRETE

FLUSH WITH EXISTING FLOOR/ DECK.

ELEVATOR

PIT

UP4" SAN

FD1 FD1

P-418

S A

N

SAN

SAN

SAN

3"

3"

6"

2"

S A

N

UP3" DCW

UP6" F1

UP2" SAN

CO

UP2" SAN

S A

N

FD3

SAN

2" VR

SAN

UP4" SAN

UP1.5" SAN

SAN

SAN

FD1FD1

P-418

SAN

D P601

TP

TP

P-524

TP

SP2

DN6" SAN

UP4" V

4"

PD

FD3

TP

SAN SAN

4" S

AN PIV

WV

12" SAN 12" SAN

SANITARY MH #2756

SLAB ON GRADE

SLAB ON GRADESLAB ON GRADE

BSMT

WV

4" SAN

B

PL100

A

PL100

UP4" SAN

CO

SP1

UP2" PD

CO

CO

TEST-Y & CO

UP4" PD

HD

A. REFER TO SHEET P001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

GENERAL NOTES

3"

FLOOR

3"

1. DUPLEX CONTROL PANEL. MOUNT 60" AFF TO

TOP OF PANEL.

2. INSTALL PIPE ACCESSORIES IN HORIZONTAL

PORTION OF PIPING.

3. POWER WIRING IN CONDUIT TO CONTROL

PANEL.

4. EXISTING VENT

5. EXISTING PUMPED DISCHARGE PIPING

6. BASIN LID

7. PUMP

8. PUMP REMOVAL RAIL SYSTEM.

9. EXISTING BASIN

2 2

7 7

P D

P D

NOTESV

CO

P D

4" 5

4"

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:4

P M

PL100

PLUMBING BASEMENT PLAN - NEW

WORK

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

BASEMENT PLAN - NEW WORK

PLAN NOTES

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.

2. PROVIDE SUMP PUMP ALARM AND CONTROL PANEL. COORDINATE LOCATION AND

REQUIREMENTS WITH DIVISION 26.

3. SANITARY ROUGH-INS FOR FUTURE FIT-OUT. RISE TO 24" ABOVE EXISTING FLOOR

SLAB AND CAP. SIZE AS INDICATED.

4. RUN PIPING AS HIGH AS POSSIBLE TO CONNECT TO EXISTING 6" SANITARY IN

BASEMENT.

5. VERIFY EXACT LOCATION, INVERTS, SIZES, CONNECTIONS AND DIRECTION OF

SANITARY PIPING PRIOR TO ANY CONSTRUCTION.

6. SUMP PUMP: SUBMERSIBLE DUPLEX SUMP SYSTEM (SP2)

CAPACITY: 75 GPM @ 46 FT. HEAD (EA)

MOTOR: 3 HP - 208V-3PH (EA)

DISCHARGE: 3" W/ CHECK & BALL VALVE. (EA)

PROVIDE NEW BASIN LID, CONTROLS AND RAIL SYSTEM.

7. PROVIDE ADAPTOR AND CONNECT TO STUB PROVIDED BY S.U.C.

KEYPLAN

SCALE: NONE

SUMP PUMP - SP2

A

SCALE: NONE

SANITARY MH# 2756

B

B F

P

BFP

TP

A. REFER TO SHEET P001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

GENERAL NOTESC D E F G H I J K L M N O P

ET1

FD2

FD1

FD1

FD1

FD1

P-502

P-418 (4)

P-418 (4)

P-524

P107

P-201

(3)

(2)

DWH1

TMV1

RP1

P-609

P-107

1.5" VR

P401

1"

0.5"

E-85

P-524

DN2" SANDN2" SAN

DN4" SAN

CO

TP

FD2

T P

DN4" SAN

UP2" V

FD3

V 3"2" VR

V

V

EXISTING WATER

SERVICE ENTRANCE

2" VR

P-804

1.5"3"

3"

2.5" 1.25" 2.5"

SAN

(5)

P-609

DN1.5" SAN

1.5" VR

1.5" VR

1.5" VR

TP

TP

SAN

SAN

S A

N

TP

UP1.25" DHW

UP2.5" DCW

UP2" V

DN4" SAN

SS

SHELL

SPACE

ELECTRICAL

CLOSET

S2-A

STAIR

FUT

FUTURE

RESTROOMS

MECHANICAL

LOBBY

ELEVATOR

EQUIPMENT

E1-A

ELEVATOR

TR

OFFICE (1)

OFFICE (1)

OFFICE (1)

OFFICE (1)

BREAK (6)

UP2" V

E P601

UP0.5" DCW

4" CONCRETE HOUSEKEEPING PAD

7 7

0.75"

TP

TP

TP

1.25"

DN4" PD 1

4"

PD

ELECTRICAL

HB

HB 1

1.5"1.5"

FD3

DWH 1

STORAGE ANNEX NIC

UP2" PD

8 8

DN2" PD

UP0.75" DHWR

0.5"

CO

CO

CO

TEST-Y & CO

1.5" HD

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:4

P M

PL101

PLUMBING FIRST FLOOR PLAN - NEW

WORK

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

PLAN NOTES

1. EXISTING AREA, PIPING OR PIECE OF EQUIPMENT (TYPE AS INDICATED) TO REMAIN.

2. PROVIDE 1" STUB FOR HVAC EQUIPMENT. PIPING TO BE CONTINUED/ COORDINATED

PER DIVISION 23.

3. SANITARY ROUGH-INS FOR FUTURE FIT-OUT. RISE TO 24" ABOVE EXISTING FLOOR

SLAB AND CAP. SIZE AS INDICATED.

4. 2" DCW, 0.75" DHW & 0.5" DHWR VALVED AND CAPPED WITH-IN TWO (2) PIPE

DIAMETERS OF ACTIVE MAIN STUBS FOR FUTURE EXTENSION. VALVES SHALL

BE LOCKED CLOSED.

5. SUMP PUMP, REFER TO DETIAL D/ P601. EXTEND PUMPED DRAINAGE PIPING UP TO

SECOND FLOOR, DISCHARGE INTO MOP BASIN.

6. SAW CUT AND TRENCH EXISTING FLOOR SLAB TO ACCOMMODATE NEW SANITARY

PIPING. PROVIDE BEDDING, BACKFILL AND COMPACTION PER SPECIFICATIONS. PATCH

CONCRETE FLUSH TO FINISHED FLOOR AND RESURFACE TO MATCH ADJACENT FLOOR

SLAB.

7. INSTALL BODY COMPLETE, INSTALL SOLID COVER & GASKET. TURNOVER STRAINER

TO COR.

8. FIXTURE SHALL BE VENTED BY A COMBINATION WASTE AND VENT SYSTEM PER IPC

SECTION 915. MAXIMUM SLOPE SHALL BE 1/2" PER FOOT BETWEEN FIXTURE AND

VENT CONNECTION OF SYSTEM.

9. PROVIDE SUMP PUMP ALARM AND CONTROL PANEL. COORDINATE LOCATION AND

REQUIREMENTS WITH DIVISION 26.

10. PROVIDE 0.75" SANITARY DRAIN FIXED AIR GAP FITTING FOR MECHANICAL

CONDENSATE DRAIN.

KEYPLAN

N

1/8" = 1'-0"

FIRST FLOOR PLAN - NEW WORK

TP

DN

C D E F G H I J K L M N O P

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

BREAK

ROOM

CLASSROOM

(17)

CLASSROOM

(17)

MECHANICAL

ROOM

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

C4

CORRIDOR

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

CLASSROOM

(17)

S1-B

STAIR

S2-B

STAIR

C3

CORRIDOR

P401

CERNER

AND

COMMAND

CENTER

(30)

PLANNING

AND PREP

ELEVATOR

LOBBY

S3-B

STAIR

HAC

ELEC.

WOMEN'S

RESTROOM

MEN'S

RESTROOM

C2

CORRIDOR

C5

CORRIDOR

C5

CORRIDOR

C5

CORRIDOR

TR

C2

CORRIDOR

VENDING

C4

CORRIDOR

CLASSROOM

(17)

P-609

FD2

VTR

1"

1"

FD2

P-804

2" VR

V

V

DN0.5" DCW

E2

FREIGHT

ELEVATOR

227A

ELEV.

SERVICE

CLASSROOM

(17)

2" VR

VTR

V

A P601

CONFERENCE

ROOM

A. REFER TO SHEET P001 FOR ABBREVIATIONS, SYMBOLS & INDEX OF DRAWINGS.

GENERAL NOTES

S.

#062-073523

REGISTERED

PROFESSIONAL

ENGINEER

OF

SIGER DERET

WE

H

T T

A M

GRAH

A

M

NO I S

ILLI

2021-05099

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

FULLY SPRINKLERED

U.S. Department of Veterans Affairs

B

C

D

E

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

PROJECT NO.

C

B

IM

\M o d e l\

-0

-P lu m b in g C e n tr a l_ rl c o n d y .r v t

/2

/2

:1

:5

P M

PL102

PLUMBING SECOND FLOOR PLAN - NEW

WORK

VAMC

02/23/2022 KMB RLC

EHRM TRAINING AND ADMIN SPACE 578-21-706

HINES, IL.

BID DOCUMENTS

EDWARD HINES

JR. VAMC

2021-05099

N

1/8" = 1'-0"

SECOND FLOOR PLAN - NEW WORK

KEYPLAN

PLAN NOTES

1. PROVIDE 1" STUB FOR HVAC EQUIPMENT. PIPING TO BE CONTINUED/ COORDINATED

PER DIVISION 23.

2. PIPING LOCATED IN CHASE/ WALL ABOVE FLOOR SLAB.

F G

P-610

P-107

P-107

P-107

P-201

P-201

P-107

P-107

P-107

P-524

P-809

P-107

P-107

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-418

P-502

FD1

FD1

FD1

F…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .