This document provides details for a federal contract opportunity to perform adaptive reuse work on the Maurice Stephens House located at Valley Forge National Historical Park. The solicitation seeks construction services including interior and exterior restoration of the existing house, installation of a new foundation and deck, and associated site and mechanical work. The NAICS code for this opportunity is 238990 for specialty trades contracting. As a total small business set-aside, only small businesses under $16.5 million in annual revenue are eligible for award. The contract value is estimated between $1,000,000 to $5,000,000 and is subject to Davis-Bacon prevailing wage requirements. Interested parties must attend a mandatory site visit and submit proposals in accordance with instructions in the solicitation. The awarding agency is the Department of the Interior National Park Service Northeast Region.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TASK ORDER NO: 20F0030

PMIS/PACKAGE NUMBER: 238128

PROJECT NUMBERS:

P O T T S T O W N

E X P

YVALLEY FORGE PARK RD

SCHU

YLKILL

RIVE

R

CO

UN

TY

L

INE

R

DGULPH RD

N

OU

TE

R

LIN

E

DR

MAURICE

STEPHENS HOUSE

VALLEY FORGE

VISITOR CENTER

MAURICE STEPHENS HOUSE

VALLEY FORGE NATIONAL HISTORICAL PARK

1400 North Outer Line Dr., King of Prussia, PA 19406

CONSTRUCTION DOCUMENTS

ADAPTIVE REUSE OF THE

OPTIONS:

OPTION A: PROVIDE LIGHTNING PROTECTION SYSTEM.

OPTION B: PROVIDE EXTERIOR WINDOW SHUTTERS.

OPTION C: PROVIDE INTERIOR STORM WINDOWS.

OPTION D: PROVIDE REINFORCING AT ELL FLOORING.

TITLE OF DRAWING DRAWING NO.

PKG

NO.

SHEET

OF

LOCATION WITHIN PARK

NAME OF PARK

REGION COUNTY STATE

UNITED STATES

DEPARTMENT OF THE INTERIOR

NATIONAL PARK SERVICE

DENVER SERVICE CENTER

Prepared in Accordance with Design Development (Title I)

OR

Variance from Design Development (Title I) approved by Superintendent on

OR

Construction Drawing Not Preceded by Design Development (Title I)

QUALITY DESIGN CERTIFICATIONMark Sheet REVISION Date Initial

ARCHITECT

JOHN G. WAITE ASSOCIATES, ARCHITECTS, PLLC

ALBANY, NY

Project Manager Date

DATE

ADAPTIVE REUSE OF THE MAURICE STEPHENS HOUSE

VALLEY FORGE PARK ROAD, KING OF PRUSSIA, PA 19406

238128 1

VALLEY FORGE NATIONAL HISTORICAL PARK

NER MONTGOMERY PA

02/18/2022

G000

1 LOCATION PLAN

DRAWING INDEX:

STRUCTURAL

S000 GENERAL NOTES - STRUCTURAL

S010 BASEMENT REMOVALS PLAN - STRUCTURAL

S011 FIRST FLOOR REMOVALS PLAN - STRUCTURAL

S012 SECOND FOOR REMOVALS PLAN - STRUCTURAL

S013 THIRD FLOOR REMOVALS PLAN - STRUCTURAL

S014 ROOF REMOVALS PLAN - STRUCTURAL

S100 BASEMENT PLAN - STRUCTURAL

S101 FIRST FLOOR PLAN - STRUCTURAL

S102 SECOND FLOOR PLAN - STRUCTURAL

S103 THIRD FLOOR PLAN - STRUCTURAL

S104 ROOF PLAN - STRUCTURAL

S200 TYPICAL DETAILS - STRUCTURAL

FIRE PROTECTION

FP001 COVER SHEET - FIRE PROTECTION

FP100 BASEMENT FLOOR PLAN - FIRE PROTECTION

FP101 FIRST FLOOR PLAN - FIRE PROTECTION

FP102 SECOND FLOOR PLAN - FIRE PROTECTION

FP103 THIRD FLOOR PLAN - FIRE PROTECTION

FP200 SCHEDULES AND RISER DIAGRAM - FIRE PROTECTION

FP300 DETAILS - FIRE PROTECTION

FP301 DETAILS - FIRE PROTECTION

PLUMBING

P001 COVER SHEET - PLUMBING

P100 BASEMENT FLOOR PLAN - PLUMBING

P101 FIRST FLOOR PLAN - PLUMBING

P102 SECOND FLOOR PLAN - PLUMBING

P103 THIRD FLOOR PLAN - PLUMBING

P104 ROOF PLAN - PLUMBING

P300 SCHEDULES - PLUMBING

P301 SCHEDULES - PLUMBING

P400 DETAILS - PLUMBING

P401 DETAILS - PLUMBING

MECHANICAL

M001 COVER SHEET - MECHANICAL

M002 FLOW AND CONTROL DIAGRAMS - MECHANICAL

M003 VRF PIPING DIAGRAMS - MECHANICAL

M100 BASEMENT FLOOR PLAN - MECHANCIAL

M101 FIRST FLOOR PLAN - MECHANCIAL

M102 SECOND FLOOR PLAN - MECHANCIAL

M103 THIRD FLOOR PLAN - MECHANCIAL

M300 SCHEDULES - MECHANICAL

M301 SCHEDULES - MECHANICAL

M400 DETAILS - MECHANICAL

M401 DETAILS - MECHANICAL

ELECTRICAL

E001 COVER SHEET - ELECTRICAL

E002 LIGHTING FIXTURE SCHEDULE - ELECTRICAL

E100 BASEMENT FLOOR PLAN - ELECTRICAL

E101 FIRST FLOOR PLAN - ELECTRICAL

E102 SECOND FLOOR PLAN - ELECTRICAL

E103 THIRD FLOOR PLAN - ELECTRICAL

E200 BASEMENT REFLECTED CEILING PLAN - LIGHTING

E201 1ST FLOOR REFLECTED CEILING PLAN - LIGHTING

E202 2ND FLOOR REFLECTED CEILNG PLAN - LIGHTING

E203 3RD FLOOR REFLECTED CEILING PLAN - LIGHTING

E400 SINGLE LINE DIAGRAM - ELECTRICAL

E401 FIRE ALARM RISER DIAGRAM - ELECTRICAL

E500 PANEL SCHEDULES - ELECTRICAL

E600 DETAILS - ELECTRICAL

E601 DETAILS - ELECTRICAL

A104 ROOF PLAN

A105 ADDITION FIRST FLOOR PLAN

A110 BASEMENT REFLECTED CEILING PLAN

A111 FIRST FLOOR REFLECTED CEILING PLAN

A112 SECOND FLOOR REFLECTED CEILING PLAN

A113 THIRD FLOOR REFLECTED CEILING PLAN

A200 SOUTH ELEVATION

A201 WEST ELEVATION

A202 NORTH ELEVATION

A203 EAST ELEVATION

A300 ADDITION SECTIONS

A301 TRANSVERSE SECTIONS

A302 LONGITUDINAL SECTION

A310 3D VIEW

A311 3D VIEW

A400 INTERIOR ELEVATIONS: B001

A401 INTERIOR ELEVATIONS: B002

A410 INTERIOR ELEVATIONS: ROOM 101

A411 INTERIOR ELEVATIONS: ROOM 102

A412 INTERIOR ELEVATIONS: ROOM 103

A413 INTERIOR ELEVATIONS: ROOM 103

A414 INTERIOR ELEVATIONS: ROOM 104

A420 INTERIOR ELEVATIONS: ROOMS 201 & 204

A421 INTERIOR ELEVATIONS: ROOMS 202 & 203

A422 INTERIOR ELEVATIONS: ROOM 205

A423 INTERIOR ELEVATIONS: ROOM 206

A424 INTERIOR ELEVATIONS: ROOMS 206 & 207

A430 INTERIOR ELEVATIONS: ROOMS 301 & 303

A431 INTERIOR ELEVATIONS: ROOM 302

A450 INTERIOR ELEVATIONS: ROOM 150

A451 INTERIOR ELEVATIONS: ROOM 150

A452 INTERIOR ELEVATIONS: ROOMS 151, 152

A501 ROOF DETAILS

A502 ROOF DETAILS

A503 ROOF DETAILS

A510 WALL SECTIONS

A511 WINDOW WELL DETAILS

A512 FOUNDATION DETAILS

A513 WINDOW WELL DETAILS

A514 BASEMENT WINDOW AND LINTEL DETAILS

A520 RAMP DETAILS

A521 DECK RAILING DETAILS

A522 STOOP DETAILS

A523 RESTORED KITCHEN STAIR

A524 BASEMENT STAIR DETAILS

A600 DOOR SCHEDULE

A601 DOOR AND WINDOW NOTES AND TYPES

A602 DOOR DETAILS

A603 DOOR DETAILS

A610 WINDOW SCHEDULE

A611 WINDOW DETAILS

A612 WINDOW SHUTTER DETAILS

A620 ROOM FINISH SCHEDULE

A621 FLOOR AND CEILING TYPES

A622 FLOOR AND CEILING TYPES

A623 WALL TYPES

A700 CASEWORK DETAILS

A701 CASEWORK DETAILS

GENERAL

G000 TITLE SHEET

C100 TOPOGRAPHIC SURVEY

C101 SITE LOCATION PLAN

C500 SITE DETAILS

BUILDING CODE

R001 CODE NOTES

R100 BASEMENT FLOOR CODE PLAN

R101 FIRST FLOOR CODE PLAN

R102 SECOND FLOOR CODE PLAN

R103 THIRD FLOOR CODE PLAN

ARCHITECTURE

D100 BASEMENT PLAN - REMOVALS

D101 FIRST FLOOR PLAN - REMOVALS

D102 SECOND FLOOR PLAN - REMOVALS

D103 THIRD FLOOR PLAN - REMOVALS

D104 ROOF PLAN - REMOVALS

D110 BASEMENT REFLECTED CEILING PLAN-REMOVALS

D111 1ST FLOOR REFLECTED CEILING PLAN-REMOVALS

D112 2ND FLOOR REFLECTED CEILING PLAN-REMOVALS

D113 3RD FLOOR REFLECTED CEILING PLAN-REMOVALS

D400 INTERIOR ELEVATIONS: B001 - REMOVALS

D401 INTERIOR ELEVATIONS: B002 - REMOVALS

D410 INTERIOR ELEVATIONS: ROOM 101 - REMOVALS

D411 INTERIOR ELEVATIONS: ROOM 102 - REMOVALS

D412 INTERIOR ELEVATIONS: ROOM 103 - REMOVALS

D413 INTERIOR ELEVATIONS: ROOM 103 - REMOVALS

D414 INTERIOR ELEVATIONS: ROOM 104 - REMOVALS

D420 INTERIOR ELEV: ROOMS 201 & 204 - REMOVALS

D421 INTERIOR ELEV: ROOMS 202 & 203 - REMOVALS

D422 INTERIOR ELEVATIONS: ROOM 205 - REMOVALS

D423 INTERIOR ELEVATIONS: ROOM 206 - REMOVALS

D424 INTERIOR ELEV: ROOMS 206 & 207 - REMOVALS

D430 INTERIOR ELEV: ROOMS 301 & 303 - REMOVALS

D431 INTERIOR ELEVATIONS: ROOM 302 - REMOVALS

A100 BASEMENT FLOOR PLAN

A101 FIRST FLOOR PLAN

A102 SECOND FLOOR PLAN

A103 THIRD FLOOR PLAN

Reinforcement to be included in base bid. Descriptions of Options D & E provided in addendum description document.

jamoore Cross-Out

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

SCHEMATIC

DESIGN

NOT FOR

CONSTRUCTION

JS

PJM V001

ADAPTIVE REUSE OF

MAURICE STEPHENS HOUSE

TOPOGRAPHIC SURVEY 238128

3 2012/11/20

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

MFS

0 20' 40'

Scale: 1" = 20'-0"

10' C100

OF2 29

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

CONSTRUCTION

DOCUMENTS 75%

NOT FOR

CONSTRUCTION

JGWA

JS

PJM C100

ADAPTIVE REUSE OF

MAURICE STEPHENS HOUSE

TOPOGRAPHIC SURVEY 238128

2 008/27/2021

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

CONSTRUCTION

DOCUMENTS 100%

NOT FOR

CONSTRUCTION

JGWA

JS

PJM C100

ADAPTIVE REUSE OF

MAURICE STEPHENS HOUSE

TOPOGRAPHIC SURVEY 238128

2 12211/05/2021

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

JS

PJM C100

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

TOPOGRAPHIC SURVEY 238128

2 15012/17/2021

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

JS

PJM C100

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

TOPOGRAPHIC SURVEY 238128

2 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

EXISTING BUILDING.EXISTING MAURICE STEPHENS HOUSE.

EXISTING STONE TERRACE RETAINING WALL.

PROVIDE ADDITION AND DECK.

PROVIDE RAMP.

PROVIDE CONCRETE PAD FOR HVAC

EQUIPMENT.

EXISTING PARKING LOT

NO WORK

EXISTING STONE SPRING HOUSE.

NO WORK.

SCALE OF FEET

DRIVEWAY TO VALLEY FORGE PARK ROAD.

PROPOSED DUMPSTER LOCATION.

DUMPSTER BY OTHERS.

REMOVE TREE.

S

S

SEPTIC TANKSEXISTING SEPTIC HOLDING TANKS

TO REMAIN.

PROVIDE INLET GRATE. TIE INTO

EXISTING DRAINAGE PIPING BELOW.

EXISTING INFORMATIONAL SIGN TO

REMAIN.

EXISTING TRANSFORMER VAULT TO BE

REMOVED BY THE GOVERNMENT.

33-4600-104 PROVIDE FOUNDATION

DRAIN AT EXISTING MAIN HOUSE. DRAIN

TO DAYLIGHT TO WEST SIDE OF BUILDING.

INVERT = 158.00' +/-

EXISTING FIRE HYDRANT TO REMAIN.

PROTECT EXISTING TREE TO

REMAIN.

EXISTING CISTERN WITH STONE

CAP TO REMAIN. N.I.C.

32-1400-104 PROVIDE PAVED STONE

PEDESTRIAN WALK.

26' - 5"

C500

ALIGN

C500

C500

C500

2 SIMILAR

C500

33-4600-116 PROVIDE CLEANOUT

FLUSH TO GRADE.

33-4600-116 PROVIDE CLEANOUT

FLUSH TO GRADE.

EXISTING INLET GRATE. TO REMAIN.

33-4600-115 PROVIDE FOUNDATION

DRAIN. DRAIN TO DAYLIGHT. INVERT =

155.85' +/-

33-4600-114 EXISTING INVERT OUT =

155.85' +/- VERIFY IN FIELD

PARKING LOT AVAILABLE FOR

CONTRACTOR PARKING AND

LAY DOWN AREA.

APPROXIMATE CONSTRUCTION

LIMIT LINE.

02-4297-032 REMOVE PORTION OF

EXISTING STONE PATH AT INTERSECTION

WITH NEW PATH.

02-4297-032 REMOVE PORTION OF

EXISTING STONE PATH AT INTERSECTION

WITH NEW PATH.

TO

SD

SD

SD

SD

E

W

W

W

W

W

W

W

W

EW

EW

EW

EW

TIE NEW WATER LINE INTO

EXISTING MAIN WITH VALVE

BOX.

33-4600-103 PROVIDE CATCH BASIN

AND INLET GRATE. REFER TO DETAIL

3/A512.

PROVIDE 4" DIAMETER WATER

MAIN.

EW

SD

W

E

EW

SD

W

E

E E

EXISTING ELECTRICAL CONDUIT AND

HAND HOLE TO TRANSFORMER ON

ROUTE 23.

LEGEND:

UNMOWED AREA.

EXISTING STORM DRAIN PIPING.

PROVIDE 6" DIAMETER STORM DRAIN PIPING.

APPROXIMATE CONSTRUCTION LIMIT LINE.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH, JDF

MKS C101

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

SITE LOCATION PLAN 238128

3 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

C101

1 SITE LOCATION PLAN

SCALE N

GENERAL NOTES - SITE

1. RESTORE DISTURBED LANDSCAPE UPON COMPLETION OF

WORK.

20 0 20 4020 0 20 40

SCALE NSCALE N

SCALE OF FEET

APPROXIMATE LOACTION OF EXISTING

WATER LINE.

EXISTING SANITARY DRAIN TO REMAIN.

PROVIDE UNDERGROUND ELECTRICAL

SERVICE.

PROVIDE 4" DIAMETER WATER MAIN.

GENERAL NOTES

C500

C500

C500

10' - 8"

11' - 8"

03-3000-004 PROVIDE REINFORCED

CONCRETE EQUIPMENT PAD

REFER TO MECHANICAL

DRAWINGS FOR HVAC

EQUIPMENT.

REFER TO ELECTRICAL

DRAWINGS FOR SERVICE OUTLET

AND DISCONNECT.

604 PROVIDE HVAC UNIT ENCLOSURE.

REFER TO CIVIL AND MECHANICAL

DRAWINGS.

LC

LC

LC

LCLC

C1

REFER TO MECHANICAL

DRAWINGS FOR HVAC

EQUIPMENT.

REFER TO MECHANICAL

DRAWINGS FOR HVAC

EQUIPMENT.

06-1000-108 PROVIDE TREATED 1X4

BOARD FENCING. TYPICAL.

03-3000-005 PROVIDE REINFORCED

CONCRETE EQUIPMENT PAD. PROVIDE #4

BARS AT 12" O.C. BOTH WAYS. PROVIDE

TURNED DOWN SLAB EDGE.

08-7100-003 PROVIDE GATE LATCH

AND HINGES.

03-3000-005 PROVIDE REINFORCED

CONCRETE EQUIPMENT PAD. PROVIDE #4

BARS AT 12" O.C. BOTH WAYS. PROVIDE

TURNED DOWN SLAB EDGE.

C1

604 PROVIDE HVAC UNIT ENCLOSURE.

REFER TO CIVIL AND MECHANICAL

DRAWINGS.

06-1000-108 PROVIDE TREATED 1X4

BOARD FENCING. TYPICAL.

06-1000-107 PROVIDE TREATED 2X4

RAILS. TYPICAL.

06-1000-109 PROVIDE METAL POST

BASE. TYPICAL.

03-3000-005 PROVIDE REINFORCED

CONCRETE EQUIPMENT PAD. PROVIDE #4

BARS AT 12" O.C. BOTH WAYS. PROVIDE

TURNED DOWN SLAB EDGE.

1' M

IN

. 6 M

IN

8"

REFER TO MECHANICAL

DRAWINGS FOR HVAC

EQUIPMENT.

33-4600-120 PROVIDE 4" CRUSHED

STONE.

REFER TO MECHANICAL

DRAWINGS FOR HVAC

EQUIPMENT.

5' - 0"

33-4600-120 PROVIDE 4" CRUSHED

STONE.

32-1400-102 PROVIDE 1 1/2" SAND

SETTING BED.

32-1400-101 PROVIDE SANDED JOINTS.

32-1400-100 PROVIDE 2" THICK STONE

PAVING.

FINISHED GRADE.

33-4600-106 PROVIDE TEN (10)

SQUARE FOOT CRUSHED GRAVEL BED AT

PIPING DAYLIGHT.

33-4600-105 PROVIDE STORM DRAIN

PIPING PER CIVIL PLAN.

33-4600-113 INVERT OUT = 159.5'

+/- VERIFY IN FIELD.

33-4600-112 PROVIDE CONCRETE

FLOOR.

33-4600-111 REMOVE PORTION OF

EXISTING CORRUGATED METAL DRAIN

PIPING.

33-4600-110 PROVIDE PRECAST

CONCRETE CATCH BASIN.

TOP OF FRAME = 165.75' +/-

VERIFY IN FIELD.

33-4600-108 PROVIDE 2-0" X 3'-0"

CAST-IRON GRATE.

33-4600-107 ALIGN TOP OF FRAME

WITH EXISTING PAVING.

33-4600-107 ALIGN TOP OF FRAME

WITH EXISTING PAVING.

EXISTING ASPHALT PAVING TO

REMAIN.

FINISHED GRADE.

32-1400-100 PROVIDE 2" THICK STONE

PAVING.

33-4600-120 PROVIDE 4" CRUSHED

STONE.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS C500

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

SITE DETAILS 238128

4 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

C500 SCALE F

3 ENCLOSURE PLAN

C500 SCALE F

6 ENCLOSURE ELEVATION - WEST

C500 SCALE F

7 ENCLOSURE ELEVATION - NORTH

C500

4 ENCLOSURE DETAIL SECTION

SCALE F

C500 SCALE F

1 STONE PAVING DETAIL

C500 SCALE F

2 DRAIN OUTFALL DETAIL

C500

5 CATCH BASIN DETAIL

SCALE F 2 0 2 4

SCALE F

SCALE OF FEET

GENERAL SYMBOL LEGEND:

A101

1 SIM

A101

NAME

ELEVATION1

A101

1i

X001

A101

VIEW NAME

SCALE A

ALIGN

A101

DETAIL NUMBER

TITLE

SCALE

DETAIL SHEET NUMBER

REFERENCING SHEET NUMBER

GRAPHIC SCALE IN FEET DENOTES ALIGNMENT OF

INDICATED SURFACES

SPECIFICATION NUMBER

DIVISION NUMBER

CENTERLINE

COLUMN GRID LINE

DATUM

SPOT ELEVATION

NORTH ARROW

1i

ROOM NAME

ROOM NUMBER

ROOM AREA

DOOR NUMBER

WINDOW NUMBER

WALL TYPE

CEILING/FLOOR TYPE

REVISION CLOUD

DETAIL NUMBER

DETAIL SHEET REFERENCE

SECTION/DETAIL NUMBER

SECTION/DETAIL SHEET

REFERENCE

ELEVATION NUMBER

ELEVATION SHEET REFERENCE

ELEVATION NUMBER - TYPICAL

ELEVATION SHEET REFERENCE

ELEVATION

UNIQUE NOTE NUMBER

XX-XXXX-XXX

1 0 1 2

SCALE OF INCHES

SCALE L

Room name

150 SF

ACM ASBESTOS CONTAINING MATERIAL

AV AUDIOVISUAL

C CENTERLINE

CMU CONCRETE MASONRY UNIT

CR CARD READER

CS CEILING SPEAKER

DN DOWN

EC ELECTRICAL CONTRACTOR

ELEV. ELEVATOR

EQ EQUAL

FLR FLOOR

HR HOUR

IT INFORMATION TECHNOLOGY

MAX. MAXIMUM

MEP MECHANICAL ELECTRICAL AND PLUMBING

MEPFP MECHANICAL ELECTRICAL PLUMBING

AND FIRE PROTECTION

P PERSONS

PSF PER SQUARE FOOT

MIN. MINIMUM

MS MOTION SENSOR

O.C. ON CENTER

OPP. OPPOSITE

OS OCCUPANCY SENSOR

S.F. SQUARE FEET

SIM. SIMILAR

STD STANDARD

TYP. TYPICAL

WAP WIRELESS ACCESS POINT

N.I.C. NOT IN CONTRACT

ABBREVIATIONS:

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS R001

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

CODE NOTES 238128

5 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

APPLICABLE CODES

2018 INTERNATIONAL BUILDING CODE

2010 ADA STANDARDS FOR ACCESSIBLE DESIGN

2015 ABASS

2021 NFPA 101

USE AND OCCUPANCY

THE BUILDING WAS CONSTRUCTED IN 1816 WITH A CIRCA 1841 ADDITION.

THE BUILDING IS CURRENTLY VACANT.

PROPOSED USES:

BASEMENT:

FIRST FLOOR:

SECOND FLOOR B:

THIRD FLOORB:

NON-SEPARATED MIXED USES ARE PERMITTED PER IBC 508.3.1.

GENERAL BUILDING HEIGHTS AND AREAS

BUILDING AREAS:

BASEMENT

FIRST FLOOR

FIRST FLOOR ADDITION

SECOND FLOOR

THIRD FLOOR

TOTAL HABITABLE SPACE

PROPOSED ENTRY PORCH

PROPOSED EXTERIOR DECK

EXISTING HEIGHT FROM AVERAGE GRADE PLANE TO AVERAGE ROOF PLANE IS

27’-0” +/-

EXISTING HEIGHT TO THE TOP OF HIGHEST CHIMNEY IS 45’-0” +/-

THE EXISTING BUILDING IS THREE STORIES.

THE PROPOSED USES COMPLY WITH IBC TABLES 504.3, 504.4 AND 506.2 FOR

HEIGHT, NUMBER OF STORIES, AND AREA, RESPECTIVELY.

TYPES OF CONSTRUCTION

THE BUILDING IS CONSTRUCTED OF RUBBLE STONE MASONRY WALLS WITH

PARTIALLY EXPOSED WOOD-FRAMED FLOORS AND ROOFS.

THE EXISTING CONSTRUCTION TYPE IS III-B.

THE PROPOSED ADDITION WILL BE WOOD-FRAMED OVER A CONCRETE

FOUNDATION. CONSTRUCTION TYPE V-B.

FIRE PROTECTION

THE BUILDING CURRENTLY HAS AN INOPERATIVE PARTIAL FIRE ALARM SYSTEM.

THE BUILDING IS NOT CURRENTLY PROTECTED WITH A SPRINKLER SYSTEM. A

SPRINKLER SYSTEM WILL BE PROVIDED THROUGHOUT THE BUILDING.

STANDPIPES ARE NOT REQUIRED PER IBC 905.3.1.

PORTABLE FIRE EXTINGUISHERS ARE REQUIRED PER IBC 906.1.

A FIRE ALARM SYSTEM WILL BE PROVIDED THROUGHOUT THE BUILDING.

MEANS OF EGRESS

DETAILED OCCUPANCY NOTES

RESTAURANT SEATING SPACE CALCULATED AT 15 SF NET PER PERSON PER IBC

TABLE 1004.5 (TABLES AND CHAIRS)

RESTAURANT SERVING AREA CALCULATED AT 5 SF PER PERSON PER IBC TABLE

1004.5 (STANDING ROOM)

RESTAURANT PREPARATION AREA CALCULATED AT 200 SF PER PERSON PER

IBC 1004.5

OFFICE SPACE CALCULATED AT 150 SF GROSS PER PERSON PER IBC TABLE

1004.5.

MECHANICAL SPACE IS CALCULATED AT 300 SF PER PERSON PER IBC TABLE

1004.5.

CAFÉ SEATING LAYOUT INDICATED ON CODE DRAWINGS AS (34 + 40 PEOPLE).

BASEMENT

ROOM 001 452 SF MECHANICAL 2 PEOPLE

ROOM 002 444 SF MECHANICAL 2 PEOPLE

SUBTOTAL 4 PEOPLE

FIRST FLOOR (PER SEATING LAYOUT)

ROOM 101 155 SFSTAIR HALL 0 PEOPLE

ROOM 102 240 SFCAFÉ PREP 3 PEOPLE

ROOM 102 120 SFCAFÉ SERVING 24 PEOPLE

ROOM 103 332 SFCAFÉ SEATING 23 PEOPLE (18 PEOPLE)

ROOM 104 275 SFCAFÉ SEATING 19 PEOPLE (16 PEOPLE)

ADDITION 268 SFNO OCCUPANCY 0 PEOPLE

SUBTOTAL 69 PEOPLE (61 PEOPLE)

OUTDOOR SEATING AREA 705 SF 47 PEOPLE (40 PEOPLE)

OUTDOOR SEATING IS NOT INCLUDED IN THE EGRESS TOTAL.

SECOND FLOOR

ROOM 201 64 SFSTAIRWAY 0 PEOPLE

ROOM 202 169 SF OFFICE 2 PEOPLE

ROOM 203 171 SF OFFICE 2 PEOPLE

ROOM 204 68 SFRESTROOM 0 PEOPLE

ROOM 205 152 SF OFFICE 2 PEOPLE

ROOM 206 183 SF OFFICE 2 PEOPLE

ROOM 207 298 SF ELL SEATING 19 PEOPLE

SUBTOTAL 27 PEOPLE

THIRD FLOOR

ROOM 301 319 SF MECHANICAL 2 PEOPLE

ROOM 302 223 SF MECHANICAL 1 PEOPLE

ROOM 303 116 SF MECHANICAL 1 PERSON

ROOM 302A 147 SF STAIR 0 PEOPLE

SUBTOTAL 4 PEOPLE

TOTAL OCCUPANTS 135 PEOPLE (120 PEOPLE)

POSTED OCCUPANCY SIGNS ARE REQUIRED IN ASSEMBLY SPACES PER IBC

1004.9

NO SINGLE SPACE IN THE BUILDING IS REQUIRED TO HAVE TWO MEANS OF

EGRESS PER IBC TABLE 1006.2.1.

IBC TABLE 1006.3.2(2) INDICATES THAT:

1. THE BASEMENT IS PERMITTED TO HAVE A SINGLE MEANS OF EGRESS. THE

MAXIMUM COMMON PATH OF TRAVEL IS 45 FEET.

2. THE FIRST FLOOR IS REQUIRED TO HAVE TWO MEANS OF EGRESS. THE

MAXIMUM COMMON PATH OF TRAVEL IS 31 FEET.

3. THE SECOND FLOOR IS PERMITTED TO HAVE A SINGLE MEANS OF EGRESS.

THE MAXIMUM COMMON PATH OF TRAVEL IS 67 FEET.

4. THE THIRD FLOOR IS REQUIRED TO HAVE TWO MEANS OF EGRESS IF

OCCUPIED. THE MAXIMUM COMMON PATH OF TRAVEL IS 113 FEET.

EMERGENCY LIGHTING IS REQUIRED PER IBC 1008.3.2.

NO SPACES HAVE AN OCCUPANT LOAD MORE THAN 50 PEOPLE, SO

ALL DOORS MAY SWING INWARD PER IBC 1010.1.2.1

EXIT SIGNS ARE NOT REQUIRED PER IBC 1013.1 EXCEPTION 1.

EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED THE MAXIMUM

PERMITTED VALUES IN IBC TABLE 1017.2 AT ANY POINT WITHIN THE

BUILDING. THE MAXIMUM TRAVEL DISTANCE IN THE BUILDING IS 113 FEET.

EXIT STAIRS ARE NOT REQUIRED TO BE ENCLOSED PER IEBC 1203.6.

PLUMBING FIXTURES

PER IBC TABLE 2902.2 THE FOLLOWING ARE REQUIRED:

FOR A-2 USE:

FOR B USE:

FOR ALL USES:

A FAMILY RESTROOM IS NOT REQUIRED PER 1109.2.1.

CODE NOTES

1 MEN’S TOILET

1 WOMEN’S TOILET

1 LAVATORY

1 TOILET

1 LAVATORY

1 DRINKING FOUNTAIN

1 SERVICE SINK1,018 SF

1,294 SF

273 SF

1,302 SF

919 SF

4,806 SF

292 SF

501 SF

MECHANICAL SPACE

A-2 RESTAURANT

OFFICES

MECHANICAL SPACE

452 SF

NORTH

BASEMENT

B001

2 P

444 SF

SOUTH

BASEMENT

B002

2 P

S02S01

N02

002.1

4 0 4 8

SCALE D

SCALE OF FEET

001.1 001.2

CRAWL SPACE

B004

1 1

CRAWL SPACE

B006

BULKHEAD

B003

COMMON PATH OF TRAVEL

45'

691 SF

CRAWL SPACE

B005

N01

1816 STONE HOUSE C. 1841 STONE ELL PROPOSED ADDITION PROPOSED DECK

ROOM NAME

ROOM NUMBER

AREA (SF)

OCCUPANT LOAD PER CODE

(OCCUPANT LOAD PER LAYOUT)

CODE SYMBOL LEGEND:

PEOPLE EGRESSING THROUGH THIS DOOR

PER CODE

(PEOPLE EGRESSING THROUGH THIS DOOR

PER LAYOUT)

ADA REQUIRED MANEUVERING CLEARANCE.

FE

FE

PROVIDE SEMI-RECESSED FIRE EXTINGUISHER

CABINET.

PROVIDE WALL-MOUNTED FIRE EXTINGUISHER.

X (X)

FLOOR GRILLS.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS R100

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

BASEMENT FLOOR CODE PLAN 238128

6 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

R100 SCALE D

1 BASEMENT FLOOR CODE PLAN

FE

jamoore Line jamoore Text Box Base bid jamoore Text Box Option D jamoore PolyLine jamoore Text Box Base Bid jamoore Line jamoore Text Box Option D

Line

P F

20 SF

BASEMENT

STAIR

101B

153 SF

CENTER HALL

330 SF

DINING ROOM

23P (18P)

21 SF

STAIR

103A

8 SF

ELL PASSAGE

103B

11 SF

STAIR

VESTIBULE

101A

275 SF

ELL DINING

19P (16P)

9 SF

ELL STAIR

104A

14 SF

ELL CLOSET

104B

121 SF

CAFE

24P

S11 S12

101.1

S13 S14

104.1

S15

104.4

104.2

N11N12

103.1101.2

N13N14

102.2

103.2

101.3

103.4

103.3

103.6

104.3

103.5

4 0 4 8

SCALE D

SCALE OF FEET

DOOR 101.1

CLEAR OPENING

WIDTH IS 34".

CLEAR HEIGHT IS

75 1/2".

PROPOSED DOOR

103.7 CLEAR

OPENING WIDTH IS

35". CLEAR

HEIGHT IS 80".

DOOR 104.1

CLEAR OPENING

WIDTH IS 30 1/2".

CLEAR HEIGHT IS

81 1/4".

DOOR 103.1

CLEAR OPENING

WIDTH IS 34 1/2".

CLEAR HEIGHT IS

70 1/2".

DOOR 104.2

CLEAR OPENING

WIDTH IS 31 1/2".

CLEAR HEIGHT IS

79 3/4".

DOOR 101.2

CLEAR OPENING

WIDTH IS 33 1/2".

CLEAR HEIGHT IS

71 1/2".

DOOR 101.1

DOOR 101.2

DOOR 103.1 DOOR 104.2

DOOR 104.1

PROPOSED DOOR 103.7

22 SF

SPRINKLER

VALVES

150A

82 SF

HALL

22 SF

JANITOR'S

CLOSET

150B

68 SF

RESTROOM

69 SF

RESTROOM

221 SF

CAFE

PREPARATION

3P

103.8

103.7

PROPOSED 22" X 30" ATTIC ACCESS

HATCH ABOVE.

PROPOSED 22" X 30" CRAWL SPACE

ACCESS PANEL.

COMMON PATH OF TRAVEL

31'

C O M M O N

P A T H

O F

T R A V E L

C O M M O N

P A T H

O F

T R A V E L

COMMON PATH OF TRAVEL 45'

ACCESSIBLE PATH TO PARKING AREA.

581 SF

TERRACE

SEATING

39P (34P)FE

FE

150.1

150.2

151.1

152.1

102.1

150.3

ROOM NAME

ROOM NUMBER

AREA (SF)

OCCUPANT LOAD PER CODE

(OCCUPANT LOAD PER LAYOUT)

CODE SYMBOL LEGEND:

PEOPLE EGRESSING THROUGH THIS DOOR

PER CODE

(PEOPLE EGRESSING THROUGH THIS DOOR

PER LAYOUT)

ADA REQUIRED MANEUVERING CLEARANCE.

FE

FE

PROVIDE SEMI-RECESSED FIRE EXTINGUISHER

CABINET.

PROVIDE WALL-MOUNTED FIRE EXTINGUISHER.

X (X)

FLOOR GRILLS.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS R101

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

FIRST FLOOR CODE PLAN 238128

7 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

R101 SCALE D

1 FIRST FLOOR CODE PLAN

GENERAL NOTES - FIRST FLOO...

1. REQUIRED CLEAR DOOR WIDTH MINIMUM 32" TO FACE

OF DOOR.

2. REQUIRED CLEAR DOOR HEIGHT MINIMUM 78".

GENERAL NOTES

jamoore PolyLine jamoore Text Box Base Bid jamoore Text Box Option E

Rectangle

169 SF

NORTHWEST

OFFICE

2P

171 SF

SOUTHWEST

OFFICE

2P

31 SF

RESTROOM

64 SF

HALL

152 SF

NORTHEAST

OFFICE

2P

183 SF

SOUTHEAST

OFFICE

2P

11 SF

STAIR

205A

298 SF

ELL SEATING

19P

4 SF

CLOSET

205B

19 SF

STAIR

103A

4 SF

CLOSET

202A

3 SF

CLOSET

203A

4 SF

CLOSET

203B

4 SF

CLOSET

202B

61 SF

MAIN STAIR

201A

202.3

202.2

203.3

203.2

S21 S22 S23 S24 S25

N27 N26 N25 N24 N23 N22 N21

S26 S27

203.1

202.1

206.1

205.1

206.2

205.4

205.3

205.2

4 0 4 8

SCALE D

SCALE OF FEET

ADDITION ATTIC

EXISTING ATTIC ACCESS ABOVE.

COMMON PATH OF TRAVEL 67'

C

OM

MO

N

PA

TH

O F

TR

AV

EL

3'

204.2

24 SF

VESTIBULE

204A

FE

204.1

204.3

ROOM NAME

ROOM NUMBER

AREA (SF)

OCCUPANT LOAD PER CODE

(OCCUPANT LOAD PER LAYOUT)

CODE SYMBOL LEGEND:

PEOPLE EGRESSING THROUGH THIS DOOR

PER CODE

(PEOPLE EGRESSING THROUGH THIS DOOR

PER LAYOUT)

ADA REQUIRED MANEUVERING CLEARANCE.

FE

FE

PROVIDE SEMI-RECESSED FIRE EXTINGUISHER

CABINET.

PROVIDE WALL-MOUNTED FIRE EXTINGUISHER.

X (X)

FLOOR GRILLS.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS R102

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

SECOND FLOOR CODE PLAN 238128

8 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

R102 SCALE D

1 SECOND FLOOR CODE PLAN

jamoore Cloud+ jamoore Cloud+ Option E

147 SF

MAIN STAIR

HALL

302A

225 SF

WEST

MECHANICAL

ROOM

2P

116 SF

NORTH ROOM

1P

W31

W32

E31

E32

ELL ATTIC

303.1

301.1

4 0 4 8

SCALE D

SCALE OF FEET

319 SF

EAST ROOM

3P

EXISTING ATTIC ACCESS ABOVE.

CO

MM

ON

P

AT

H

OF

T

RA

VE

L

3'

302.1

FE

HEADROOM AT STAIRS IS

BELOW REQUIRED MINIMUM.

ROOM NAME

ROOM NUMBER

AREA (SF)

OCCUPANT LOAD PER CODE

(OCCUPANT LOAD PER LAYOUT)

CODE SYMBOL LEGEND:

PEOPLE EGRESSING THROUGH THIS DOOR

PER CODE

(PEOPLE EGRESSING THROUGH THIS DOOR

PER LAYOUT)

ADA REQUIRED MANEUVERING CLEARANCE.

FE

FE

PROVIDE SEMI-RECESSED FIRE EXTINGUISHER

CABINET.

PROVIDE WALL-MOUNTED FIRE EXTINGUISHER.

X (X)

FLOOR GRILLS.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS R103

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

THIRD FLOOR CODE PLAN 238128

9 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

R103 SCALE D

1 THIRD FLOOR CODE PLAN

NOTES - THIRD FLOOR CODE PLAN

1. OFFICE OCCUPANCY INDICATED FOR THIS FLOOR IS FOR

REFERENCE ONLY FOR A POTENTIAL FUTURE PHASE. NO

OCCUPANCY BEYOND MECHANICAL SPACE IS PROPOSED

FOR THIS FLOOR IN THIS PROJECT.

2. EXSTING CEILING HEIGHT THROUGHOUT THIS FLOOR IS

APPROXIMATELY 82". MINIMUM REQUIRED IS 90".

GENERAL NOTES

jamoore Cloud+ jamoore

UP

S02S01

N02

002.1

4 0 4 8

SCALE D

SCALE OF FEET

001.1 001.2

E01

02-4297-008 REMOVE WOOD STAIR.

02-4297-002 PARTIALLY DISMANTLE

WOOD AND SHEET METAL COMPONENTS

OF ASH DUMP ENCLOSURE LID. SALVAGE

AND LABEL ALL COMPONENTS.

37'-0" X 12'-8"

37'-0" X 12'-8"

16'-7" X 18'-0"

452 SF

NORTH

BASEMENT

444 SF

SOUTH

BASEMENT

298 SF

ELL CRAWL

SPACE

19 SF

BULKHEAD

02-4297-001 REMOVE OIL TANKS AND

ASSOCIATED PIPING.

02-4297-001 REMOVE OIL TANKS AND

ASSOCIATED PIPING.

02-4297-029 REMOVE BOILER.

D400

D400

D400

D401

D401

D401

D401

D400

NO1

02-4297-059 REMOVE WOOD POST.

LEGEND:

REMOVE ITEM.

REMOVE FLOORING.

SALVAGE WOOD FLOORING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D100

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

BASEMENT PLAN - REMOVALS 238128

10 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

D100 SCALE D

1 BASEMENT REMOVALS PLAN

GENERAL NOTES

1. REMOVE ALL HEATING, PLUMBING, ELECTRICAL, FIRE

PROTECTION, AND SECURITY WIRING, DEVICES, AND

HARDWARE.

DN

UP

UP

S11 S12

101.1

S13 S14

104.1

S15

104.4

104.2

N11N12

103.1101.2

N13N14

102.2

101.3

103.4

103.3

103.6

104.3

103.5 UP

103.7

103.8

UP

UP

14'-2" X 26'-10"

7'-4" X 26'-10"

12'-10" X 26'-10"

16'-7" X 18'-0"

20 SF

BASEMENT

STAIR

101B

155 SF

CENTER HALL

330 SF

HISTORIC

KITCHEN

20 SF

KITCHEN STAIR

103A

8 SF

ELL PASSAGE

103B

11 SF

STAIR

VESTIBULE

101A

275 SF

ELL KITCHEN

9 SF

ELL STAIR

104A

14 SF

ELL CLOSET

104B

360 SF

DOUBLE

PARLOR

4 0 4 8

SCALE D

SCALE OF FEET

02-4297-004 REMOVE WOOD STAIR

AND LANDING.

02-4297-010 REMOVE WOOD

BULKHEAD DOOR AND STONE MASONRY

KNEEWALLS.

02-4297-007 REMOVE EXISTING

MASONRY STEPS AND LANDING. SALVAGE

STONE FOR RE-USE.

02-4297-007 REMOVE EXISTING

MASONRY STEPS AND LANDING. SALVAGE

STONE FOR RE-USE.

02-4297-014 REMOVE PORTION OF

WALL FINISH AND FRAMING.

02-4297-013 REMOVE FRAME INFILL AT

MASONRY OPENING.

02-4297-011 REMOVE UPPERMOST

LAYER OF WOOD FLOORING THIS ROOM

ONLY.

02-4297-015 REMOVE BOXED-OUT

FRAMING AND FINISHES.

D410

D410

D410

D410

D410

D400

D411

D411

D411

D411

D412

D412

D412

D412

D413

D413

D413

D413

D413

D414

D414

D414

D414

02-4297-015 REMOVE BOXED-OUT

FRAMING AND FINISHES.

02-4297-033 REMOVE FIN-TUBE

RADIATOR.

02-4297-033 REMOVE FIN-TUBE

RADIATOR.

02-4297-033 REMOVE FIN-TUBE

RADIATOR.

02-4297-034 REMOVE ELECTRICAL

PANEL.

D400

02-4297-035 REMOVE HANDRAIL.

02-4297-036 SALVAGE STONE PAVING.

02-4297-037 REMOVE DOWNSPOUT.

D424

102.1

02-4297-033 REMOVE FIN-TUBE

RADIATOR.

02-4297-061 SALVAGE EXISTING WOOD

FLOORING.

LEGEND:

REMOVE ITEM.

REMOVE FLOORING.

SALVAGE WOOD FLOORING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D101

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

FIRST FLOOR PLAN - REMOVALS 238128

11 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

D101 SCALE D

1 FIRST FLOOR REMOVALS PLAN

GENERAL NOTES

1. REMOVE ALL HEATING, PLUMBING, ELECTRICAL, FIRE

PROTECTION, AND SECURITY WIRING, DEVICES, AND

202.3

202.2

203.3

203.2

S21 S22 S23 S24 S25

N27 N26 N25 N24 N23 N22 N21

S26 S27

203.1

202.1

206.1

205.1

206.2

205.4

205.3

205.2

DN

4 0 4 8

SCALE D

SCALE OF FEET

UP

12'-10" X 13'-2"

12'-10" X 13'-4" 14'-8" X 13'-3"

11'-6" X 13'-3"

16'-7" X 18'-0"

7'-4" X 4'-5"

7'-4" X 10'-8"

169 SF

NORTHWEST

CHAMBER

171 SF

SOUTHWEST

CHAMBER

69 SF

BATHROOM

64 SF

HALL

152 SF

NORTHEAST

CHAMBER

183 SF

SOUTHEAST

CHAMBER

11 SF

STAIR

205A

298 SF

ELL CHAMBER

4 SF

CLOSET

205B

19 SF

CLOSET

205C

4 SF

CLOSET

202A

3 SF

CLOSET

203A

4 SF

CLOSET

203B

4 SF

CLOSET

202B

61 SF

MAIN STAIR

201A

02-4297-019 SALVAGE WOOD SHELVES.

02-4297-019 SALVAGE WOOD SHELVES.

02-4297-018 REMOVE WOOD BOARDS

AND PIPING AT HISTORIC HEARTH.

02-4297-018 REMOVE WOOD BOARDS

AND PIPING AT HISTORIC HEARTH.

02-4297-018 REMOVE WOOD BOARDS

AND PIPING AT HISTORIC HEARTH.

02-4297-017 REMOVE ALL FIXTURES

AND MODERN FINISHES THIS SPACE.

HISTORIC FLOORING AND PLASTER TO

REMAIN.

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

D420

D420

D420

D421

D421

D421

D421

D421

D421

D421

D421

D422

D422

D422

D422

D423

D423

D423

D423

D424

D424

D424

D424

D420

D420

D413

02-4297-038 REMOVE CARPET.

02-4297-038 REMOVE CARPET.

02-4297-039 REMOVE DEBRIS.

D424

D424

D420

204.1

1 3

08-1433-101 REMOVE EXISTING DOOR

PANEL.

LEGEND:

REMOVE ITEM.

REMOVE FLOORING.

SALVAGE WOOD FLOORING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D102

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

SECOND FLOOR PLAN - REMOVALS 238128

12 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

D102 SCALE D

1 SECOND FLOOR REMOVALS PLAN

GENERAL NOTES

1. REMOVE ALL HEATING, PLUMBING, ELECTRICAL, FIRE

PROTECTION, AND SECURITY WIRING, DEVICES, AND

W31

W32

E31

E32

303.1

301.1

DN

4 0 4 8

SCALE D

SCALE OF FEET

14'-4" X 8'-6"

22'-7" X 13'-5"

14'-4" X 22'-3"

02-4297-020 REMOVE MODERN KNEE

WALL FRAMING.

02-4297-020 REMOVE MODERN KNEE

WALL FRAMING.

D430

D430

D430

D430

D431

D431

D430

D430

D430

D430

8 D422

D422

D422

D431

D431

D431

02-4297-040 SALVAGE DOORS.

116 SF

NORTH ROOM

319 SF

EAST ROOM

378 SF

MAIN STAIR

187 SF

ELL ATTIC

02-4297-055 REMOVE ATTIC HATCH.

LEGEND:

REMOVE ITEM.

REMOVE FLOORING.

SALVAGE WOOD FLOORING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D103

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

THIRD FLOOR PLAN - REMOVALS 238128

13 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

D103 SCALE D

1 THIRD FLOOR REMOVALS PLAN

GENERAL NOTES

1. REMOVE ALL HEATING, PLUMBING, ELECTRICAL, FIRE

PROTECTION, AND SECURITY WIRING, DEVICES, AND

4 0 4 8

SCALE D

SCALE OF FEET

02-4297-021 REMOVE EXISTING WOOD

SHINGLES, SHEET METAL GUTTERS AND

FLASHING.

02-4297-021 REMOVE EXISTING WOOD

SHINGLES, SHEET METAL GUTTERS AND

FLASHING.

LEGEND:

REMOVE EXISTING WOOD SHINGLES, SHEET METAL

GUTTERS AND FLASHING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D104

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

ROOF PLAN - REMOVALS 238128

14 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

KAO, ES

D104

1 ROOF REMOVALS PLAN

SCALE D

GENERAL NOTES

1. REMOVE ALL HEATING, PLUMBING, ELECTRICAL, FIRE

PROTECTION, AND SECURITY WIRING, DEVICES, AND

SOUTH

BASEMENT

NORTH

BASEMENT

ELL CRAWL

SPACE

4 0 4 8

SCALE D

SCALE OF FEET

02-4297-025 REMOVE WOOD BOARD

CEILING.

02-4297-025 REMOVE WOOD BOARD

CEILING.

02-4297-025 REMOVE WOOD BOARD

CEILING.

LEGEND:

REMOVE HISTORIC WOOD BOARD

CEILING.

REMOVE ITEMS INDICATED BY

DASHED LINES.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D110

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

BASEMENT REFLECTED CEILING PLAN-REMOVALS 238128

15 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D110 SCALE D

1 BASEMENT REFLECTED CEILING PLAN - REMOVALS

1. REMOVE ALL CONDUIT AND PIPING - THIS FLOOR.

REMOVE ABANDONED

SURFACE-MOUNTED WIRING,

CONDUIT, AND DEVICES. REFER

TO ELECTRICAL.

DOUBLE

PARLOR

CENTER HALL

HISTORIC

KITCHEN

ELL KITCHEN

02-4297-054 REMOVE FURRED OUT

GYPSUM BOARD CEILING - THIS ROOM.

4 0 4 8

SCALE D

SCALE OF FEET

02-4297-056 REMOVE PORTION OF

CEILING TO INSTALL PLUMBING PIPING.

LEGEND:

REMOVE CONDUIT OR DEVICE.

REMOVE PORTION OF CEILING TO INSTALL

PLUMBING PIPING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D111

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

1ST FLOOR REFLECTED CEILING PLAN-REMOVALS 238128

16 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D111 SCALE D

1 FIRST FLOOR REFLECTED CEILING PLAN - REMOVALS

NORTHWEST

CHAMBER

SOUTHWEST

CHAMBER

HALL

BATHROOM

SOUTHEAST

CHAMBER

NORTHEAST

CHAMBER

ELL CHAMBER

4 0 4 8

SCALE D

SCALE OF FEET

02-4297-055 REMOVE ATTIC HATCH.

LEGEND:

REMOVE CONDUIT OR DEVICE.

REMOVE PORTION OF CEILING TO INSTALL

PLUMBING PIPING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D112

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

2ND FLOOR REFLECTED CEILING PLAN-REMOVALS 238128

17 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D112 SCALE D

1 SECOND FLOOR REFLECTED CEILING PLAN - REMOVALS

NORTH ROOM

EAST ROOM

MAIN STAIR

4 0 4 8

SCALE D

SCALE OF FEET

LEGEND:

REMOVE CONDUIT OR DEVICE.

REMOVE PORTION OF CEILING TO INSTALL

PLUMBING PIPING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D113

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

3RD FLOOR REFLECTED CEILING PLAN-REMOVALS 238128

18 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D113 SCALE D

1 THIRD FLOOR REFLECTED CELING PLAN - REMOVALS

N02

02-4297-001 REMOVE OIL TANKS AND

ASSOCIATED PIPING.

02-4297-001 REMOVE OIL TANKS AND

ASSOCIATED PIPING.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

001.2 001.1

02-4297-045 REMOVE PIPING.

02-4297-045 REMOVE PIPING.

02-4297-058 REMOVE WOOD LINTEL.

SEE S010.

02-4297-058 REMOVE WOOD LINTEL.

SEE S010.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

101.3 103.4

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-024 REMOVE EXISTING

HANDRAIL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH, EAS

MKS D400

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: B001 - REMOVALS 238128

19 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D400 SCALE F

1 ELEVATION - ROOM B001 NORTH REMOVALS

D400 SCALE F

3 ELEVATION - ROOM B001 SOUTH REMOVALS

D400 SCALE F

4 ELEVATION - ROOM B001 WEST REMOVALS

D400 SCALE F

2 ELEVATION - ROOM B001 EAST REMOVALS

2 0 2 4

SCALE F

SCALE OF FEET

D400 SCALE F

5 ELEVATION - ROOM 101A WEST REMOVALS

D400 SCALE F

6 ELEVATION - ROOM 101A NORTH REMOVALS

D400 SCALE F

7 ELEVATION - ROOM 101A EAST REMOVALS

001.1 001.2

02-4297-045 REMOVE PIPING.02-4297-045 REMOVE PIPING.

02-4297-058 REMOVE WOOD LINTEL.

SEE S010.

02-4297-058 REMOVE WOOD LINTEL.

SEE S010.

002.1

02-4297-058 REMOVE WOOD LINTEL.

SEE S010.

S02 S01

02-4297-002 PARTIALLY DISMANTLE

WOOD AND SHEET METAL COMPONENTS

OF ASH DUMP ENCLOSURE LID. SALVAGE

AND LABEL ALL COMPONENTS.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D401

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: B002 - REMOVALS 238128

20 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D401 SCALE F

1 ELEVATION - ROOM B002 NORTH REMOVALS

D401 SCALE F

2 ELEVATION - ROOM B002 EAST REMOVALS

D401 SCALE F

3 ELEVATION - ROOM B002 SOUTH REMOVALS

D401 SCALE F

4 ELEVATION - ROOM B002 WEST REMOVALS

2 0 2 4

101.2 101.3

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-015 REMOVE BOXED-OUT

FRAMING AND FINISHES.

02-4297-045 REMOVE PIPING.

101.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-045 REMOVE PIPING.

02-4297-015 REMOVE BOXED-OUT

FRAMING AND FINISHES.

102.2

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-031 REMOVE INTERPRETIVE

PANEL.

102.1

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D410

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 101 - REMOVALS

238128

21 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D410 SCALE F

1 ELEVATION - HALL 101 NORTH REMOVALS

D410 SCALE F

2 ELEVATION - HALL 101 STAIR REMOVALS

D410 SCALE F

3 ELEVATION - HALL 101 EAST REMOVALS

D410 SCALE F

4 ELEVATION - HALL 101 SOUTH REMOVALS

D410 SCALE F

5 ELEVATION - HALL 101 WEST REMOVALS

2 0 2 4

N13N14

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

102.2

02-4297-026 REMOVE FELT BOARD.

102.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

S12 S11

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D411

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 102 - REMOVALS 238128

22 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D411 SCALE F

1 ELEVATION - ROOM 102 NORTH REMOVALS

D411 SCALE F

2 ELEVATION - ROOM 102 EAST REMOVALS

D411 SCALE F

3 ELEVATION - ROOM 102 SOUTH REMOVALS

D411 SCALE F

4 ELEVATION - ROOM 102 WEST REMOVALS

2 0 2 4

103.1

N12

02-4297-005 REMOVE MODERN

FINISHES TO EXPOSE STONE INFILL AT

HISTORIC FIREPLACE OPENING.

103.6

103.5

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

S14 S13

103.3

02-4297-042 REMOVE COAT RACK.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-042 REMOVE COAT RACK.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D412

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 103 - REMOVALS 238128

23 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D412 SCALE F

1 ELEVATION - ROOM 103 NORTH

D412 SCALE F

2 ELEVATION - ROOM 103 EAST

D412 SCALE F

3 ELEVATION - ROOM 103 SOUTH

D412 SCALE F

4 ELEVATION - ROOM 103 WEST

2 0 2 4

205.3

103.5

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

CLOSET 205C

02-4297-016 REMOVE INFILL FLOORING

AND FRAMING AT HISTORIC STAIR

OPENING. REMOVE SHELF AND HANGING

ROD.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D413

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 103 - REMOVALS 238128

24 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D413 SCALE F

1 ELEVATION - ROOM 103A WEST REMOVALS

D413 SCALE F

2 ELEVATION - ROOM 103A NORTH REMOVALS

D413 SCALE F

3 ELEVATION - ROOM 103A EAST STAIR REMOVALS

D413 SCALE F

4 ELEVATION - ROOM 103B NORTH REMOVALS

D413 SCALE F

5 ELEVATION - ROOM 103B SOUTH REMOVALS

D413 SCALE F

6 ELEVATION - STAIR 205C SOUTH REMOVALS

2 0 2 4

SCALE F

CLOSET 205C

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

104.2 104.4

N11

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

104.3

02-4297-027 SALVAGE INTERPRETIVE

PANEL. DELIVER TO GOVERNMENT.

S15

104.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-027 SALVAGE INTERPRETIVE

PANEL. DELIVER TO GOVERNMENT.

02-4297-042 REMOVE COAT RACK.

02-4297-043 REMOVE WOOD. PATCH

ANCHOR HOLES.

02-4297-043 REMOVE WOOD. PATCH

ANCHOR HOLES.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D414

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 104 - REMOVALS 238128

25 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D414 SCALE F

1 ELEVATION - ROOM 104 NORTH REMOVALS

D414 SCALE F

2 ELEVATION - ROOM 104 EAST REMOVALS

D414 SCALE F

3 ELEVATION - ROOM 104 SOUTH REMOVALS

D414 SCALE F

4 ELEVATION - ROOM 104 WEST REMOVALS

2 0 2 4

205.1 206.1

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

204.1

202.1203.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

08-1433-101 REMOVE EXISTING DOOR

PANEL.

N25

02-4297-051 REMOVE BATHTUB AND

SURROUND.

02-4297-052 REMOVE TOILET.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-049 REMOVE SOAP

DISPENSER.

02-4297-048 REMOVE MIRROR.

02-4297-050 REMOVE VANITY, SINK,

AND FAUCET.

02-4297-051 REMOVE BATHTUB AND

SURROUND.

204.1 S23

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-047 REMOVE EXISTING TOILET

PAPER DISPENSER. PATCH HOLES IN

CHAIR RAIL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

D420

D420

D420

D420

204.1

02-4297-051 REMOVE BATHTUB AND

SURROUND.

02-4297-050 REMOVE VANITY, SINK,

AND FAUCET.

02-4297-052 REMOVE TOILET.

BATHROOM

02-4297-057 REMOVE SHEET FLOORING

DOWN TO HISTORIC WOOD FLOORING.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D420

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEV: ROOMS 201 & 204 - REMOVALS 238128

26 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D420 SCALE F

8 ELEVATION - HALL 201 EAST W/ RAILING REMOVALS

D420 SCALE F

9 ELEVATION - HALL 201 SOUTH REMOVALS

D420 SCALE F

5 ELEVATION - HALL 201 WEST REMOVALS

D420 SCALE F

6 ELEVATION - STAIR 201A NORTH REMOVALS

D420 SCALE F

7 ELEVATION - STAIR 201A EAST REMOVALS

D420 SCALE F

2 ELEVATION - RESTROOM 204A EAST REMOVALS

D420 SCALE F

4 ELEVATION - RESTROOM 204A WEST REMOVALS

D420 SCALE F

1 ELEVATION - RESTROOM 204A NORTH REMOVALS

D420 SCALE F

3 ELEVATION - RESTROOM 204 SOUTH REMOVALS

2 0 2 4

SCALE F

SCALE OF FEET

D420

10 PLAN - RESTROOM 204 - REMOVALS

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

N27 N26

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

202.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

202.2 202.3

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

203.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

08-1433-101 REMOVE EXISTING DOOR

PANEL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

S22 S21

203.2 203.3

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D421

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEV: ROOMS 202 & 203 - REMOVALS 238128

27 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D421 SCALE F

1 ELEVATION - ROOM 202 NORTH REMOVALS

D421 SCALE F

2 ELEVATION - ROOM 202 EAST REMOVALS

D421 SCALE F

3 ELEVATION - ROOM 202 SOUTH REMOVALS

D421 SCALE F

4 ELEVATION - ROOM 202 WEST REMOVALS

D421 SCALE F

5 ELEVATION - ROOM 203 NORTH REMOVALS

D421 SCALE F

6 ELEVATION - ROOM 203 EAST REMOVALS

D421 SCALE F

7 ELEVATION - ROOM 203 SOUTH REMOVALS

D421 SCALE F

8 ELEVATION - ROOM 203 WEST REMOVALS

2 0 2 4

N24 N23

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

205.2

205.3 205.4

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

206.2

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

205.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

205.2

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D422

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 205 - REMOVALS 238128

28 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D422 SCALE F

1 ELEVATION - ROOM 205 NORTH REMOVALS

D422 SCALE F

2 ELEVATION - ROOM 205 EAST REMOVALS

D422 SCALE F

3 ELEVATION - ROOM 205 SOUTH REMOVALS

D422 SCALE F

4 ELEVATION - ROOM 205 WEST REMOVALS

D422 SCALE F

5 ELEVATION - STAIR 205A WEST REMOVALS

D422 SCALE F

6 ELEVATION - STAIR 205A NORTH REMOVALS

D422 SCALE F

7 ELEVATION - STAIR 205A EAST REMOVALS

2 0 2 4

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

206.2

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

S25 S24

206.1

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D423

ADAPTIVE REUSE OF THE

MAURICE STEPHENS HOUSE

INTERIOR ELEVATIONS: ROOM 206 - REMOVALS 238128

29 15002/18/2022

VALLEY FORGE NATIONAL HISTORICAL PARK

KING OF PRUSSIA, PA 19406

D423 SCALE F

1 ELEVATION - ROOM 206 NORTH REMOVALS

D423 SCALE F

2 ELEVATION - ROOM 206 EAST REMOVALS

D423 SCALE F

3 ELEVATION - ROOM 206 SOUTH REMOVALS

D423 SCALE F

4 ELEVATION - ROOM 206 WEST REMOVALS

2 0 2 4

S27 S26

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

N22 N21N21

02-4297-023 REMOVE ABANDONED

ELECTRICAL DEVICES,

SURFACE-MOUNTED WIRING, AND

CONDUIT - TYPICAL.

02-4297-024 REMOVE EXISTING

HANDRAIL.

LEGEND - INTERIOR ELEVATIONS:

REMOVE INDICATED ITEM.

REMOVE WALL.

DESIGNED:

TECH REVIEW:

DATE:

SUB SHEET NO. TITLE OF SHEET DRAWING NO.

PMIS/PKG NO.

SHEET

OF

JGWA

EAD, PH

MKS D424

ADAPTIVE…

This is the start of the file's text. The full file is on GovTribe.