Attachment 2 Drawing Plans.pdf

PDF 3 MB Posted

Attached to
Roof Repair- Fort Bliss, T. X.
Solicitation number
W911RX-26-B-A003
Issued by

About this file

This document is a set of architectural and construction drawings for a roof replacement project at Building 2417, Fort Bliss, Texas, prepared by the Directorate of Public Works Engineering Services Division.

The project involves the complete demolition of the existing roof system and installation of a new roof assembly. The drawings specify detailed construction requirements including base flashing details with surface-mounted counterflashing at concrete walls, expansion joint flashing with metal covers, prefabricated metal curb flashing, wood curb flashing, plumbing vent details with premanufactured boots, and membrane-coated metal penetration pockets. Key construction notes mandate that the contractor maintain a complete set of construction documents, utilize standard specifications, ensure proper field verification, maintain a clean construction area, provide temporary containment/heating units during construction, obtain all required permits, comply with safety protocols, protect existing utilities, and follow all federal, state, and local regulations. The new roof system specifications include fully adhered 60 mil TPO membrane with accessories such as underlayment, waterproofing, roof drains, edge protection, insulation, tapered wood systems, and compatible accessories. All work must comply with manufacturer specifications and recommendations. The drawings also include site plans, demolition work plans, new work plans, general notes for existing conditions, and detailed construction specifications for various roof penetration and termination conditions.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D P

W

FO

R T

B

LI

SS

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

COVER SHEET

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text

FORT BLISS, TEXAS

AutoCAD SHX Text

INDEX OF DRAWINGS

AutoCAD SHX Text

NO.

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

PROJECT LOCATION MAP

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text N

AutoCAD SHX Text

PROJECT LOCATION

AutoCAD SHX Text 1 = COVER SHEET 2 = SITE PLAN 3 = DEMOLITION WORK PLAN 4 = NEW WORK PLAN 5 = DETAILS 6 = DETAILS (CONTINUED) 7 = PROJECT INFORMATION SIGNAGE DETAIL

AutoCAD SHX Text

CVRSHT

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

CASSIDY RD.

AutoCAD SHX Text

HINMAN RD.

AutoCAD SHX Text

RICKER RD.

AutoCAD SHX Text

CHAFFEE RD.

AutoCAD SHX Text

CARRINGTON RD.

AutoCAD SHX Text

BLDG. 2417

AutoCAD SHX Text

HINMAN RD.

AutoCAD SHX Text

MED-10211-5J

W

FO

R T

B

LI

SS

N

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-100

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text

SCALE: 1"=50'

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

CASSIDY RD.

AutoCAD SHX Text

CHAFFEE RD.

AutoCAD SHX Text

BLDG. 2417

AutoCAD SHX Text

CONSTRUCTION LIMITS

AutoCAD SHX Text

LAY-DOWN AREA

AutoCAD SHX Text

GENERAL NOTES (EXISTING CONDITIONS)

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text CONSTRUCTION LIMITS - CONSTRUCTION AREA TO USE DEMARCATION POINTS SUCH AS FENCING, CURBS, ETC., WHEREVER FEASIBLE UNLESS OTHERWISE NOTED.

AutoCAD SHX Text

REMOVE EXISTING ROOF SYSTEM

AutoCAD SHX Text LAY DOWN YARD TO BE SUBMITTED BY CONTRACTOR AND APPROVED BY COR & MASTER PLANNING

AutoCAD SHX Text

MED-10211-5J

AutoCAD SHX Text

1. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 2. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS (DRAWINGS, SOW, AND SPECIFICATIONS) ON SITE AT ALL TIMES AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 3. CONTRACTOR SHALL UTILIZE STATEMENT OF WORK, SPECIFICATIONS, CONTRACTOR SHALL UTILIZE STATEMENT OF WORK, SPECIFICATIONS, DRAWINGS AND CONTRACT TO ENSURE ALL CONSTRUCTION, DELIVERABLES, AND RESOURCES ARE DELIVERED TO THE GOVERNMENT. 4. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD IMMEDIATELY VIA RFI, TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 5. PRIOR TO ANY CHANGE OR MODIFICATION TO THE DRAWINGS DUE PRIOR TO ANY CHANGE OR MODIFICATION TO THE DRAWINGS DUE TO ACTUAL CONDITIONS, DPW REPRESENTATIVE SHALL BE NOTIFIED FOR REVIEW AND APPROVAL. 6. CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA IN CONTRACTOR SHALL MAINTAIN AND CLEAN CONSTRUCTION AREA IN ACCORDANCE WITH THE CONTRACT AND SAFETY RECOMMENDATIONS. 7. PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL CONDUCT A PRIOR TO CONSTRUCTION START, CONTRACTOR SHALL CONDUCT A THOROUGH PHOTOGRAPHIC SURVEY OF THE SITE. CRACKED SIDEWALKS, BROKEN WINDOWS, BENT EQUIPMENT, ETC. THIS INCLUDES INVENTORY OF ALL ITEMS ON SITE AND THEIR CONDITION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RESPONSIBILITY TO REPAIR. 8. BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE BUILDING WILL BE OCCUPIED DURING CONSTRUCTION. PROVIDE TEMPORARY COOLING/HEATING UNITS IF NECESSARY, DURING PERIODS AC AND HEATER ARE DOWN. 9. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. CONTRACTOR SHALL PROVIDE BUILDING ACCESS TO USER. 10. CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL CONTRACTOR SHALL PROVIDE AND FURNISH TRAFFIC CONTROL FOR AREA ADJACENT TO CONSTRUCTION AREA. CONTRACTOR SHALL PROVIDE ALL REQUIRED TRAFFIC CONTROL PLANS. ALL SIGNS, BARRICADES, CHANNELIZATION DEVICES, SIGN FRAMES AND ERECTION OF SUCH DEVICES SHALL CONFORM TO THE REQUIREMENTS OF THE LOCAL TRAFFIC CONTROL AUTHORITY. 11. CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING CONTRACTOR SHALL PROVIDE VEHICULAR ACCESS TO PARKING SPACES. 12. NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF NO OBSTRUCTIONS WILL BE PERMITTED WITHIN THREE FEET OF FIRE HYDRANTS. 13. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO EXISTING ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 14. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION WASTE AND DEMOLITION MATERIALS AND DEBRIS BE RECYCLED. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION FOR APPROVAL. 15. CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS AND FINISHES THAT ARE TO REMAIN. ANY DAMAGES SHALL BE REPLACED OR RESTORED WITHOUT ADDITIONAL COST TO THE GOVERNMENT. 16. ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS ANY DEMOLITION DEBRIS SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER REPRESENTATIVE PRIOR TO CONTINUING ANY ADDITIONAL WORK. 17. ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND TESTED ALL REMOVED EQUIPMENT SHALL BE REINSTALLED AND TESTED IN THE PRESENCE OF A CONTRACTING OFFICER REPRESENTATIVE. 18. EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR EXISTING SITE IMPROVEMENTS DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 19. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 20. ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S ALL WORK SHALL COMPLY WITH ALL MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL REGULATIONS/CODES.

AutoCAD SHX Text

LAY-DOWN ARE NOTES

AutoCAD SHX Text

1. LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START OF LAY-DOWN AREA SHALL BE DESIGNATED PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL COORDINATE WITH DPW MASTER PLANNING. 2. THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND THE CONTRACTOR SHALL RESTORE ANY ACCESS ROADS AND LAY-DOWN AREAS USED DURING CONSTRUCTION BACK TO THEIR ORIGINAL STABILIZED CONDITION OR BETTER. 3. CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND CONTRACTOR SHALL PROVIDE AND INSTALL ALL EQUIPMENT AND SUPPLIES REQUIRED TO SECURE THE TEMPORARY STORAGE AREA.

AutoCAD SHX Text

1. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, WHETHER IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR, WHETHER INDICATED ON THE DRAWING OR NOT, TO VERIFY THE LOCATION, DEPTH, AND CONDITION OF ALL EXITING UTILITIES AND SUBSTRUCTURES AND PROTECT THEM FROM ANY DAMAGE. 2. THE CONTRACTOR SHALL CONTACT ALL THE UTILITY COMPANIES AND CONDUCT ALL NECESSARY FIELD INVESTIGATIONS PRIOR TO ANY EXCAVATION. ANY DAMAGE TO EXISTING UTILITIES SHALL BE PROMPTLY REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO GOVERNMENT. 3. NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 NOTIFY THE DPW REPRESENTATIVE IN WRITING AT LEAST 14 DAYS BEFORE ANY UTILITY OUTAGE OR ROAD CLOSURE.

UTILITY NOTES

W

FO

R T

B

LI

SS

N N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-101

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text

DEMOLITION KEY NOTES

AutoCAD SHX Text

DEMOLITION GENERAL NOTES

AutoCAD SHX Text

EXISTING ROOF SYSTEM

AutoCAD SHX Text

EXISTING EXHAUST FAN

AutoCAD SHX Text

EXISTING EXHAUST VENT

AutoCAD SHX Text

EXISTING PIPE PENETRATION

AutoCAD SHX Text

EXISTING LIGHT SENSOR

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text E

AutoCAD SHX Text

EXISTING ANTENNA

AutoCAD SHX Text

EXISTING ELECTRICAL PENETRATION

AutoCAD SHX Text H

AutoCAD SHX Text

ABANDONED HVAC LINE PENETRATION

AutoCAD SHX Text

ABANDONED HVAC STAND

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

DEMOLITION WORK PLAN

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION WORK PLAN

AutoCAD SHX Text

SCALE: 1/16"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

DEMOLITION WORK PLAN

AutoCAD SHX Text

SCALE: 1/16"=1'-0"

AutoCAD SHX Text 268'

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text 38'-10"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text 19'-4"

AutoCAD SHX Text 12'-2"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text 8'-4"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text

MATCH-LINE

AutoCAD SHX Text

MATCH-LINE

AutoCAD SHX Text 35'-6"

AutoCAD SHX Text 21'-11"

AutoCAD SHX Text 87'

AutoCAD SHX Text 34'-6"

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text V.I.F.

AutoCAD SHX Text

MED-10211-5J

AutoCAD SHX Text

1. THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION, THE EXACT LOCATION AND QUANTITY OF EXISTING DUCTWORK, PENETRATIONS AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. CONTRACTOR MUST FIELD VERIFY AND EXAMINE EXISTING STRUCTURES, NOTE ALL CONDITIONS AS TO CHARACTER AND EXTENT OF ALL WORK INVOLVED, VALIDATE AND BID ACCORDINGLY. 2. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITIES BEFORE COMMENCING WORK. 3. GENERAL CONTRACTOR SHALL ASSURE THAT ALL GENERAL CONTRACTOR SHALL ASSURE THAT ALL SUB-CONTRACTORS HAVE REVIEWED THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, THIS INCLUDES BUT NOT LIMITED TO CONSTRUCTION DRAWINGS, SOW, SPECIFICATIONS, AMENDMENTS, MODIFICATIONS, AND CHANGE ORDERS. THE CONTRACT IS BASED ON CONSTRUCTION DOCUMENTS AS A WHOLE AND COORDINATION BETWEEN SUBCONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF THE DEMOLITION PLAN INDICATES THE GENERAL SCOPE OF ITEMS AND EXISTING CONSTRUCTION ELEMENTS TO BE REMOVED. ANY ADDITIONAL ITEMS ENCOUNTERED IN THESE GENERAL DEMOLITION AREAS, WHICH WILL INTERFERE WITH THE NEW CONSTRUCTION SHALL ALSO BE REMOVED AT NOT ADDITIONAL COST. 5. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 6. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 7. CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ALL REQUIRED BARRICADES, FENCING, COVERED WALKS, PLANKING, LIGHTING, BRACING, SHORING, WARNING SIGNS, ETC. AS REQUIRED BY OSHA AND FORT BLISS REGULATIONS FOR THE PROTECTION OF WORKMEN, STAFF AND USERS. 8. CONTRACTOR SHALL PROTECT ALL GOVERNMENT PROPERTY CONTRACTOR SHALL PROTECT ALL GOVERNMENT PROPERTY TO INCLUDE CARS, EQUIPMENT AND BUILDING SYSTEMS. 9. THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL THE CONTRACTOR IS RESPONSIBLE TO PROTECT ALL EXISTING EQUIPMENT, MATERIALS, AND FINISHES THAT ARE TO REMAIN AND WITHOUT UNNECESSARY DAMAGE. ITEMS AND MATERIAL TO BE REMOVED SHALL BE DONE IN SUCH A MANNER AS TO PREVENT DAMAGES TO ITEMS AND MATERIALS THAT REMAIN. SUCH DAMAGES SHALL BE REPAIRED OR REPLACED TO THE SATISFACTION OF THE DPW REPRESENTATIVE AND AT NO ADDITIONAL COST TO THE GOVERNMENT. ITEMS INCLUDE BUT ARE NOT LIMITED TO BROKEN CURBS, CRACKED SIDEWALKS, ETC. 10. THE CONTRACTOR SHALL OVERSEE CLEANING AND THE CONTRACTOR SHALL OVERSEE CLEANING AND ENSURE THAT THE PREMISES ARE MAINTAINED RUBBISH FREE DURING DEMOLITION WORK. FINAL CLEANUP IS THE RESPONSIBILITY OF THE CONTRACTOR. 11. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 12. THE GOVERNMENT RESERVES THE FIRST RIGHT OF THE GOVERNMENT RESERVES THE FIRST RIGHT OF REFUSAL FOR ALL DEMOLITION ITEMS. THOSE DEMOLITION ITEMS THE GOVERNMENT DOES NOT WISH TO KEEP SHALL BECOME PROPERTY OF THE CONTRACTOR FOR PROPER DISPOSAL. 13. ANY ITEMS SCHEDULED FOR DEMOLITION SUSPECTED TO ANY ITEMS SCHEDULED FOR DEMOLITION SUSPECTED TO CONTAIN HAZARDOUS MATERIALS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE COR PRIOR TO DEMOLITION. 14. CONTRACTOR TO VALIDATE/VERIFY LEAD OR ASBESTOS CONTRACTOR TO VALIDATE/VERIFY LEAD OR ASBESTOS MATERIAL TO BE REMOVED/ABATED. CONTRACTOR SHALL COMPLY WITH ALL REGULATORY REQUIREMENTS APPLICABLE TO LEAD AND ASBESTOS ABATEMENT AS INDICATED IN SURVEYS AND TESTED. 15. CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF DECK OR STRUCTURAL REPAIRS ARE NEEDED FOR GOVERNMENT CONSIDERATION. UNLESS NOTED OTHERWISE, CONTRACTOR WILL BID ON AN ESTIMATED 500 SF OF ROOF DECK AREA TO BE REPLACED AND PROVIDE FULL REPLACEMENT TO INCLUDE STEEL ANGLE REINFORCEMENT SUPPORT AS NEEDED. 16. THE CONTRACTOR SHOULD ENSURE THAT THE WORKERS THE CONTRACTOR SHOULD ENSURE THAT THE WORKERS ARE 10-FEET AWAY FROM RIO GRANDE ELECTRIC SERVICE WIRE. THE CONTRACTOR SHOULD SUBMIT A DMO THROUGH THE SERVICE ORDER DESK TO RGEC IF A COVER UP (RUBBER BLANKET) IS REQUIRED AT LEAST THREE DAYS PRIOR. 17. CONTRACTOR TO LIFT ALL MECHANICAL EQUIPMENT IN CONTRACTOR TO LIFT ALL MECHANICAL EQUIPMENT IN PLACE TO ALLOW FOR CONSTRUCTION AND REINSTALL ONCE CONSTRUCTION IS COMPLETE. 18. CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR CONTRACTOR SHALL PROVIDE TEMPORARY SUPPORT FOR ALL EXISTING UTILITIES INCLUDING BUT NOT LIMITED TO ELECTRICAL CONDUIT, GAS LINES, WIRES, ETC., AS REQUIRED TO ALLOW FOR CONSTRUCTION. 19. SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES EXPOSED ON THE ROOF. PRIME WITH ONE COAT AND PROVIDE TWO COATS OF SAFETY YELLOW PAINT. 20. ANY ABANDONED PENETRATIONS SHALL BE REMOVED ANY ABANDONED PENETRATIONS SHALL BE REMOVED AND THE DECK REPAIRED PRIOR TO INSTALLATION OF THE NEW ROOF SYSTEM. SECURE ALL SLEEVES AND PIPES BEFORE ROOF MATERIAL IS REMOVED. 21.CONTRACTOR WILL FIELD VERIFY BEFORE MOVING ANY ABANDONED PENETRATIONS. 22.ALL EQUIPMENT TO BE REMOVED SHALL BE DONE SO IN THE PRESENCE OF A GOVERNMENT REPRESENTATIVE AND INSTALLED AND TESTED IN THE PRESENCE OF A GOVERNMENT REPRESENTATIVE. 23.CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 24.THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH BINS TO DISPOSE OF CONSTRUCTION MATERIALS. 25.BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.

1 REMOVE EXISTING ROOF SYSTEM DOWN TO THE DECK. REMOVE EXISTING ROOF SYSTEM DOWN TO THE DECK. CLEAN AND PREPARE SURFACE. CONTRACTOR TO FIELD VERIFY EXISTING DRIP EDGE DIMENSION, NEW DRIP EDGE TO BE EQUAL IN DIMENSION AND PROFILE. SECURE VENTS AND OTHER ROOF PROJECTIONS, AND DRIVE PROJECTING NAILS FIRMLY HOME. CONTRACTOR TO ASSUME 500 SF OF METAL DECK REPLACEMENT, SEE DEMOLITION GENERAL NOTE #15. THE CONTRACTOR TO NOTIFY THE COR OF ANY STRUCTURAL CONCERNS. 2 RREMOVE ALL EXISTING BASE FLASHING, FLASHING, RREMOVE ALL EXISTING BASE FLASHING, FLASHING, COUNTER FLASHING, STEP FLASHING, ETC. AT EXISTING PIPE PENETRATIONS, EXHAUST FAN, ROOF VENTS, CHIMNEYS, PARAPETS, ETC. PREPARE FOR NEW FLASHING, TYPICAL. 3 REMOVE EXISTING GUTTERS AND DOWNSPOUTS. REMOVE EXISTING GUTTERS AND DOWNSPOUTS. CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS AND PROFILES. NEW GUTTERS AND DOWNSPOUT TO BE EQUAL TO EXISTING. ORIGINAL ANCHOR POINTS FOR STRAPS ON BUILDING SHOULD BE REUSED FOR INSTALLATION OF NEW LEADER HEAD AND DOWNSPOUT. 4 ALL EXISTING ROOF TOP EQUIPMENT (ANTENNAS, VENTS, ALL EXISTING ROOF TOP EQUIPMENT (ANTENNAS, VENTS, EXHAUST FANS, HVAC, EVAP UNITS, ETC.) TO INCLUDE WATER, GAS AND ELECTRICAL LINES SHALL BE PROTECTED DURING CONSTRUCTION. REMOVE IF NECESSARY TO ALLOW FOR CONSTRUCTION AND REINSTALL ONCE CONSTRUCTION IS COMPLETE. COORDINATE WITH GOVERNMENT REPRESENTATIVE AND BUILDING'S PERSONNEL PRIOR TO DISCONNECT ANY EQUIPMENT. 5 HAZARDOUS MATERIAL - THE CONTRACTOR SHALL REVIEW HAZARDOUS MATERIAL - THE CONTRACTOR SHALL REVIEW THE ASBESTOS AND LEAD SURVEY REPORTS PROVIDED WITH THIS SOW TO DETERMINE IF ANY ASBESTOS AND LEAD CONTAINING MATERIALS WILL BE IMPACTED BY THIS PROJECT. THE CONTRACTOR SHALL INFORM THE KO AND COR IF ANY ASBESTOS AND LEAD CONTAINING MATERIALS WILL BE IMPACTED DURING CONSTRUCTION. THE CONTRACTOR SHALL HIRE A LICENSED ABATEMENT COMPANY BY THE STATE OF TEXAS IF ANY MATERIAL WILL NEED TO BE ABATED PRIOR CONSTRUCTION AND SUBMIT TEST RESULTS AFTER ABATEMENT IS COMPLETED. THE CONTRACTOR SHALL SUBMIT AN ABATEMENT PLAN TO THE GOVERNMENT FOR REVIEW AND APPROVAL PRIOR TO STARTING ANY ABATEMENT WORK. CONTRACTOR TO FOLLOW ALL STATE AND LOCAL REQUIREMENTS FOR ABATEMENT.

W

FO

R T

B

LI

SS

N N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-102

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

AutoCAD SHX Text

NEW WORK PLAN

AutoCAD SHX Text

SCALE: 1/16"=1'-0"

AutoCAD SHX Text

MATCH-LINE

AutoCAD SHX Text

AutoCAD SHX Text

NEW WORK PLAN

AutoCAD SHX Text

SCALE: 1/16"=1'-0"

AutoCAD SHX Text

MATCH-LINE

AutoCAD SHX Text

NEW WORK KEY NOTES

AutoCAD SHX Text

NEW WORK GENERAL NOTES

AutoCAD SHX Text

NEW ROOF SYSTEM

AutoCAD SHX Text

EXISTING EXHAUST FAN

AutoCAD SHX Text

EXISTING EXHAUST VENT

AutoCAD SHX Text

EXISTING PIPE PENETRATION

AutoCAD SHX Text

EXISTING LIGHT SENSOR

AutoCAD SHX Text

LEGEND

AutoCAD SHX Text E

AutoCAD SHX Text

EXISTING ANTENNA

AutoCAD SHX Text

EXISTING ELECTRICAL PENETRATION

AutoCAD SHX Text

NEW WORK PLAN

AutoCAD SHX Text

MED-10211-5J

AutoCAD SHX Text

1. THESE PLANS ARE FOR REFERENCE ONLY AND MAY THESE PLANS ARE FOR REFERENCE ONLY AND MAY NOT REFLECT ALL AVAILABLE INFORMATION, THE EXACT LOCATION AND QUANTITY OF EXISTING DUCTWORK, PENETRATIONS AND EQUIPMENT MAY DEVIATE FROM LOCATIONS AND QUANTITY SHOWN ON DRAWINGS. CONTRACTOR MUST FIELD VERIFY AND EXAMINE EXISTING STRUCTURES, NOTE ALL CONDITIONS AS TO CHARACTER AND EXTENT OF ALL WORK INVOLVED, VALIDATE AND BID ACCORDINGLY. 2. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS, ALL DIMENSIONS, EXACT LOCATIONS AND QUANTITY BEFORE COMMENCING WORK. 3. GENERAL CONTRACTOR SHALL ASSURE THAT ALL GENERAL CONTRACTOR SHALL ASSURE THAT ALL SUB-CONTRACTORS HAVE REVIEWED THE ENTIRE SET OF CONSTRUCTION DOCUMENTS, THIS INCLUDES BUT NOT LIMITED TO CONSTRUCTION DRAWINGS, SOW, SPECIFICATIONS, AMENDMENTS, MODIFICATIONS, AND CHANGE ORDERS. THE CONTRACT IS BASED ON CONSTRUCTION DOCUMENTS AS A WHOLE AND COORDINATION BETWEEN SUBCONTRACTOR IS THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. 4. CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A CONTRACTOR SHALL BE RESPONSIBLE TO MAINTAIN A COMPLETE SET OF CONSTRUCTION DOCUMENTS ON SITE AND INDICATE CHANGES AS THE PROJECT PROGRESSES. 5. CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S CONTRACTOR SHALL NOTIFY CONTRACTING OFFICER'S FIELD REPRESENTATIVE IMMEDIATELY OF ANY CONFLICTS DISCOVERED IN THE FIELD VIA RFI, ASAP TO ALLOW SUFFICIENT TIME TO REVIEW AND RESOLVE THE ISSUE. 6. CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING CONTRACTOR SHALL ENSURE SAFE ACCESS TO BUILDING DURING CONSTRUCTION AND SHALL PROVIDE ALL REQUIRED BARRICADES, FENCING, COVERED WALKS, PLANKING, LIGHTING, BRACING, SHORING, WARNING SIGNS, ETC. AS REQUIRED BY OSHA AND FORT BLISS REGULATIONS FOR THE PROTECTION OF WORKMEN, STAFF AND USERS. 7. ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S ALL WORK SHALL COMPLY WITH THE MANUFACTURER'S SPECIFICATIONS/RECOMMENDATIONS, FEDERAL, STATE, AND LOCAL CODES. 8. NO NEW MATERIALS SHALL CONTAIN ASBESTOS, LEAD, NO NEW MATERIALS SHALL CONTAIN ASBESTOS, LEAD, OR ANY REGULATED MATERIALS. 9. PROVIDE NEW ROOF SYSTEM, INSULATION, ROOF BOARD PROVIDE NEW ROOF SYSTEM, INSULATION, ROOF BOARD AND UNDERLAYMENT. 30 YEAR MANUFACTURERS WARRANTY WITH 130 MPH PEAK GUST WIND SPEED COVERAGE. 10. ALL ROOF PENETRATION AND FLASHING WORK SHALL BE ALL ROOF PENETRATION AND FLASHING WORK SHALL BE THE RESPONSIBILITY OF ROOFING CONTRACTOR USING MANUFACTURER'S STANDARD DETAILS AND SHALL BE COVERED AS PART OF THE MANUFACTURER'S WARRANTY. CONTRACTOR WILL PROVIDE ALL NEW ACCESSORIES, PIPE SUPPORTS, PIPE BOOTS, CANT STRIPS, ETC. SUPPORTS SHALL NOT PENETRATE THE NEW ROOF SYSTEM. 11. ALL SHEET METAL INCLUDING COPING, GUTTERS, ALL SHEET METAL INCLUDING COPING, GUTTERS, FLASHING, TRIM, LEADER BOXES AND LEADERS ARE TO BE SUPPLIED BY METAL ROOFING MANUFACTURER AND INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. ALL GAUGES OF SHEET METAL SHALL BE ACCORDING TO MANUFACTURERS RECOMMENDATIONS. 12. ALL ROOF AND WALL PANEL TERMINATIONS, COPING, ALL ROOF AND WALL PANEL TERMINATIONS, COPING, EDGE METAL, SHALL MEET ES-1 STANDARDS. 13. SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS SECURE AND SAFEGUARD EXISTING AND\OR NEW GAS LINES EXPOSED ON THE ROOF. PRIME WITH ONE COAT AND PROVIDE TWO COATS OF SAFETY YELLOW PAINT. 14. CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE CONTRACTOR SHALL IDENTIFY AREAS OF ROOF WHERE ROOF DECK OR STRUCTURAL REPAIRS ARE NEEDED FOR GOVERNMENT CONSIDERATION. UNLESS NOTED OTHERWISE, CONTRACTOR WILL BID ON AN ESTIMATED 500 SF OF ROOF DECK AREA TO BE REPLACED AND PROVIDE FULL REPLACEMENT TO INCLUDE STEEL ANGLE REINFORCEMENT SUPPORT AS NEEDED. 15. PROVIDE TAPERED INSULATION CRICKETS AT HIGH SIDES PROVIDE TAPERED INSULATION CRICKETS AT HIGH SIDES OF ALL ROOF MOUNTED EQUIPMENT, SKYLIGHTS, CORNERS, ETC. AND ALONG WALLS AS REQUIRED TO PROVIDE POSITIVE DRAINAGE. SLOPE FOR ALL CRICKETS SHALL MATCH THE ADJACENT ROOF ASSEMBLY, SLOPE = 1/4" PER FOOT. REFER TO NRCA ROOFING MANUAL, CURRENT EDITION. 16. THE CONTRACTOR SHOULD ENSURE THAT THE WORKERS THE CONTRACTOR SHOULD ENSURE THAT THE WORKERS ARE 10-FEET AWAY FROM RIO GRANDE ELECTRIC SERVICE WIRE. THE CONTRACTOR SHOULD SUBMIT A DMO THROUGH THE SERVICE ORDER DESK TO RGEC IF A COVER UP (RUBBER BLANKET) IS REQUIRED AT LEAST THREE DAYS PRIOR. 17. PROVIDE AND INSTALL SIX, STAINLESS STEEL, MINIMUM PROVIDE AND INSTALL SIX, STAINLESS STEEL, MINIMUM 5,000 LB (22.2 kN) TENSILE STRENGTH 'D' RING TYPE PERMANENT FALL PROTECTION ROOF ANCHORS. ROOF ANCHORS SHALL COMPLY WITH OSHA 1926.502. INSTALL IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS. 18. REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, REMOVE AND REPLACE ALL DAMAGED NAILERS, SOFFIT, AND FASCIA BOARDING TO MATCH EXISTING MATERIALS. 19. ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE ALL SURFACES IN CONTACT WITH NEW WORK THAT ARE DAMAGED DUE TO NEW WORK IN PROGRESS, SHALL BE PATCHED AND REPAIRED AS REQUIRED. 20.EXISTING SITE DAMAGED BY THE CONTRACTOR SHALL BE REMOVED AND REPLACED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. ITEMS INCLUDE BUT ARE NOT LIMITED TO BROKEN CURBS, CRACKED SIDEWALKS, ETC. 21. CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS CONSTRUCTION & DEMOLITION DIVERSION: FORT BLISS REQUIRES A MINIMUM OF 60% OF CONSTRUCTION AND DEMOLITION MATERIALS AND DEBRIS FROM LANDFILLS. IF THE CONTRACTOR HAS A VALID REASON FOR NOT BEING ABLE TO MEET THIS DIVERSION GOAL, THE CONTRACTOR NEEDS TO PRESENT THEIR REASONING IN WRITING TO DPW-ENVIRONMENTAL DIVISION. 22. THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS THE CONTRACTOR SHALL NOT EMPLOY FORT BLISS TRASH BINS FOR DISPOSE OF CONSTRUCTION MATERIALS. 23. BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.BURNING ON FORT BLISS PROPERTY IS NOT PERMITTED.

1 PROVIDE AND INSTALL FULLY ADHERED 80 MIL TPO PROVIDE AND INSTALL FULLY ADHERED 80 MIL TPO ROOFING MEMBRANE SYSTEM INCLUDING ROOFING ACCESSORIES, E.G. UNDERLAYMENT, WATERPROOFING, ROOF BOARD, RIGID INSULATION, TAPERED RIGID INSULATION, CANT STRIPS AT CRICKETS, TERMINATION BARS, FLASHING AND COUNTERFLASHING, CONTINUOUS BEAD OF SEALANTS, EXPANSION AND CONTROL JOINT COVERS, FASCIA, EAVES, RACKS, SOFFITS, VENTS, GUTTERS/DOWNSPOUTS, AND BAFFLES. 2 NEW TPO ROOFING MEMBRANE SYSTEM OVER COVER NEW TPO ROOFING MEMBRANE SYSTEM OVER COVER BOARD, FULLY ADHERED 80 MIL, SCRIM OR FABRIC REINFORCED, R38 INSULATION AND 5/8-INCH GLASS-MAT ROOF BOARD. POLYISOCYANURATE (POLYISO) FOAM BOARD INSULATION SYSTEM R38 AND FACER MATERIAL SHALL BE COMPATIBLE WITH MEMBRANE APPLICATION AND APPROVED AND SUPPLIED BY TPO MEMBRANE MANUFACTURER. INSTALL IN ACCORDANCE WITH ROOFING MANUFACTURERS DETAILS REQUIRED TO MEET MANUFACTURER'S 30 YEAR ROOF WARRANTY 120 MPH WIND SPEED COVERAGE. TPO MEMBRANE TO EXTEND 18 INCHES UP PARAPET WALLS. PROVIDE NEW TAPPERED RIGID INSULATION FOR POSITIVE DRAINAGE. ROOFING SYSTEM INCLUDING ALL FLASHING TO BE VALIDATED AND INSPECTED BY MANUFACTURER'S REPRESENTATIVE DURING AND AFTER CONSTRUCTION COMPLETION. 3 PROVIDE FULLY ADHERED TPO ROOF WALK PADS AS PROVIDE FULLY ADHERED TPO ROOF WALK PADS AS MANUFACTURED BY ROOF MANUFACTURER. TEXTURED NON-REINFORCED TPO MATERIAL, MINIMUM THICKNESS OF 0.150-INCH, MINIMUM WIDTH AND LENGTH OF PAD MUST BE 30-INCHES X 30-INCHES. LOCATED AT ROOF MOUNTED MECHANICAL EQUIPMENT AND OTHER MACHINERY REQUIRING PERIODIC MAINTENANCE. 4 CONTRACTOR TO INCLUDE 500 SF OF ROOF DECK CONTRACTOR TO INCLUDE 500 SF OF ROOF DECK REPLACEMENT. NEW PLANKS SHALL BE EQUAL IN DIMENSION TO EXISTING ROOF PLANKS. CONTRACTOR TO FIELD VERIFY DECK IS SOUND AND DRY. REPLACE AREAS THAT EXHIBIT SIGNS OF DETERIORATION. IF BROKEN OR LOOSE FASTENERS THAT SECURE DECK PANELS TO ONE ANOTHER OR TO THE STRUCTURE ARE OBSERVED OR IF DECK APPEARS OR FEELS INADEQUATELY ATTACHED, NOTIFY THE COR IMMEDIATELY. 5 PROVIDE NEW BASE FLASHING AND NEW PROVIDE NEW BASE FLASHING AND NEW PREFABRICATED METAL COVERS AT ALL EXISTING EXPANSION JOINTS. PROVIDE CONTINUOUS SEALANT AT ALL JOINTS. ALL NEW FLASHING AND TRIM ITEMS FOR THE NEW TPO ROOF SYSTEM SHALL BE FROM THE SAME TPO ROOFING MANUFACTURER. CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS. 6 PROVIDE NEW PRE-MANUFACTURED TPO MEMBRANE PROVIDE NEW PRE-MANUFACTURED TPO MEMBRANE PIPE BOOTS AND PIPING AT ALL PIPE PENETRATIONS. RAISE ALL PIPE PENETRATIONS AS NECESSARY TO ALLOW FOR NEW ROOF SYSTEM. PROVIDE CONTINUOUS SEALANT AT ALL JOINTS. ALL NEW ITEMS FOR THE NEW TPO ROOF SYSTEM SHALL BE FROM THE SAME TPO ROOFING MANUFACTURER. CONTRACTOR TO FIELD VERIFY EXISTING DIMENSIONS. 7 PROVIDE AND INSTALL ALL NEW 24-GAUGE STEEL PROVIDE AND INSTALL ALL NEW 24-GAUGE STEEL GUTTERS WITH FACTORY APPLIED KYNAR FINISH COMPLETE WITH AL NECESSARY ACCESSORIES FOR INSTALLATION. NEW GUTTERS TO BE EQUAL IN DIMENSION AND PROFILE TO EXISTING. CONTRACTOR TO SHOP DRAWINGS FOR APPROVAL. 8 PROVIDE AND INSTALL ALL NEW 24-GAUGE PROVIDE AND INSTALL ALL NEW 24-GAUGE GALVANIZED DOWNSPOUTS WITH FACTORY APPLIED KYNAR FINISH COMPLETE WITH AL NECESSARY ACCESSORIES FOR INSTALLATION. NEW DOWNSPOUTS TO BE EQUAL IN DIMENSION AND PROFILE TO EXISTING. ORIGINAL ANCHOR POINTS FOR STRAPS ON BUILDING SHOULD BE REUSED. CONTRACTOR TO SUBMIT SHOP DRAWINGS FOR APPROVAL. INSTALL NEW SPLASH BLOCKS. 9 NEW PERMANENT 'D' RING TYPE FALL PROTECTION NEW PERMANENT 'D' RING TYPE FALL PROTECTION ROOF NEW PERMANENT 'D' RING TYPE FALL PROTECTION ROOF ANCHORS. ANCHORS SHALL BE INSTALLED PRIOR TO ROOF SYSTEM INSTALLATION. COORDINATE WITH THE MANUFACTURER TO ENSURE INSTALLATION WILL NOT VOID THE ROOF WARRANTY. REFERENCE NEW WORK GENERAL NOTE #17. 10 ALL EXISTING ANTENNA ARE TO BE PROTECTED ALL EXISTING ANTENNA ARE TO BE PROTECTED DURING ALL EXISTING ANTENNA ARE TO BE PROTECTED DURING CONSTRUCTION. REINSTALL ANY ANTENNA THAT WERE REMOVED ONCE CONSTRUCTION IS COMPLETE.

W

FO

R T

B

LI

SS

¾

¾

¾

¾

¾

¾

¾

¾

¾

¾

¾¾

¾

¾

¾

¾

¾

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-103

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

AutoCAD SHX Text

MEMBRANE-COATED METAL PENETRATION POCKET-DOUBLE PENETRATION

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

BASE FLASHING WITH SURFACE-MOUNTED COUNTERFLASHING AT CONCRETE WALL

AutoCAD SHX Text

AutoCAD SHX Text

BASE FLASHING AT EXPANSION JOINT WITH METAL COVER

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

BASE FLASHING AT PREFABRICATED METAL CURB

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

BASE FLASHING AT WOOD CURB

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

PLUMBING VENT (PREMANUFACTURED BOOT)

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

SEAM PLATES AND FASTENERS¾ SEE NOTE 2

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

INSTALL COMPATIBLE SEALANT OR TAPE BEHIND MEMBRANE

AutoCAD SHX Text

TERMINATION BAR FASTENED WITH APPROPRIATE FASTENERS APPROX. 12'' O.C.

AutoCAD SHX Text

INSTALL COMPRESSIBLE ELASTOMERIC SEALANT OR TAPE TO SPAN IRREGULARITIES

AutoCAD SHX Text

SHEET-METAL COUNTERFLASHING ¾ SEE NOTES 3

AutoCAD SHX Text INSTALL APPROPRIATE SEALANT (E.G., POLYURETHANE) AND TOOL TO FACILITATE WATER RUNOFF

AutoCAD SHX Text

CONCRETE FASTENERS

AutoCAD SHX Text

8'' MINIMUM

AutoCAD SHX Text

FLASHING HEIGHT

AutoCAD SHX Text

ADHERED MEMBRANE FLASHING

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

1. THIS DETAIL DOES NOT ALLOW FOR DIFFERENTIAL MOVEMENT BETWEEN THE DECK AND WALL. THIS DETAIL DOES NOT ALLOW FOR DIFFERENTIAL MOVEMENT BETWEEN THE DECK AND WALL. 2. REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS. 3. REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR COUNTERFLASHINGS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text 2 x 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾ OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text

TOP OF CURB TO DRAIN TO ONE SIDE

AutoCAD SHX Text

COMPRESSIBLE INSULATION

AutoCAD SHX Text

FLEXIBLE LINER TO SERVE AS INSULATION RETAINER (ATTACHED TO TOP OF CURB)

AutoCAD SHX Text

FLASHING HEIGHT

AutoCAD SHX Text

8'' MINIMUM

AutoCAD SHX Text

ON LOW SIDE

AutoCAD SHX Text

SEAM PLATES AND FASTENERS¾SEE NOTE 3SEE NOTE 3

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

ADHERED MEMBRANE FLASHING

AutoCAD SHX Text

FLEXIBLE WEATHERPROOF MEMBRANE CLOSURE

AutoCAD SHX Text

SHEET-METAL EXPANSION JOINT COVER WITH T-TYPE CLEAT ¾ SEE NOTES 4

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

1. THIS DETAIL ALLOWS FOR BUILDING MOVEMENT IN MULTIPLE DIRECTIONS. THIS DETAIL ALLOWS FOR BUILDING MOVEMENT IN MULTIPLE DIRECTIONS. 2. FLASHING REQUIREMENTS ARE TYPICAL FOR BOTH SIDES OF THE EXPANSION JOINT. FLASHING REQUIREMENTS ARE TYPICAL FOR BOTH SIDES OF THE EXPANSION JOINT. 3. REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS. 4. REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR EXPANSION JOINT COVERS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

PREMANUFACTURED EXPANSION JOINT COVER

AutoCAD SHX Text

OPTION

AutoCAD SHX Text

WOOD NAILER

AutoCAD SHX Text

PREFABRICATED METAL CURB

AutoCAD SHX Text 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾OVERALL OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text

SEAM PLATES AND FASTENERS¾SEE NOTE 5SEE NOTE 5

AutoCAD SHX Text

FLASHING HEIGHT

AutoCAD SHX Text

8'' MINIMUM

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

ROOFTOP EQUIPMENT FRAME

AutoCAD SHX Text

SEALING MATERIAL¾MUST MUST BE CONTINUOUS ON TOP OF THE CURB

AutoCAD SHX Text

OPTIONAL

AutoCAD SHX Text

ROOF MEMBRANE

AutoCAD SHX Text

INSULATION

AutoCAD SHX Text

RAISED CURB

AutoCAD SHX Text

BASE OF UNIT EXTENDS 1/2'' MINIMUM BEYOND TOP OF CURB

AutoCAD SHX Text

FASTENERS

AutoCAD SHX Text

COUNTERFLASHING

AutoCAD SHX Text

WOOD NAILER

AutoCAD SHX Text

FLASHING RECEIVER

AutoCAD SHX Text

1'' MINIMUM BELOW TOP OF CURB

AutoCAD SHX Text

MECHANICAL UNIT, HOOD, ETC.

AutoCAD SHX Text

REMOVABLE SHEET-METAL COUNTERFLASHING ¾ SEE NOTES 6

AutoCAD SHX Text

GASKETED FASTENERS¾MIN. MIN. TWO FASTENERS PER SIDE

AutoCAD SHX Text

ADHERED MEMBRANE FLASHING

AutoCAD SHX Text

PREFABRICATED CORNER FLASHING PIECE AT EACH CORNER

AutoCAD SHX Text

FASTENERS APPROX. 8" O.C., MIN. TWO PER SIDE

AutoCAD SHX Text

OPTION A: CURB-BEARING LOCATION FOR HEAVYWEIGHT- LOADING CONDITIONS

AutoCAD SHX Text

OPTION B: CURB-BEARING LOCATION FOR TYPICAL LOADING CONDITIONS

AutoCAD SHX Text

1. THE CURBS, TOP WOOD NAILER AND SEAL STRIP ARE TO BE THE CURBS, TOP WOOD NAILER AND SEAL STRIP ARE TO BE SUPPLIED BY THE CURB MANUFACTURER. 2. WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE SET WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. 3. WHERE THE SKYLIGHT, SCUTTLE OR SMOKE VENT FRAME OVERLAPS WHERE THE SKYLIGHT, SCUTTLE OR SMOKE VENT FRAME OVERLAPS THE BASE FLASHING AT LEAST 3 INCHES, THE REMOVABLE SHEET-METAL COUNTERFLASHING IS NOT REQUIRED. 4. NRCA RECOMMENDS DESIGNERS CONSIDER PERMANENT INTERNAL OR NRCA RECOMMENDS DESIGNERS CONSIDER PERMANENT INTERNAL OR EXTERNAL FALL-PROTECTION DEVICES AT ALL SKYLIGHTS. 5. REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS. 6. REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR COUNTERFLASHINGS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

SEALING MATERIAL

AutoCAD SHX Text

SEAM PLATES AND FASTENERS¾SEE NOTE 5SEE NOTE 5

AutoCAD SHX Text

WOOD CURB

AutoCAD SHX Text 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾OVERALL OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text

FLASHING HEIGHT

AutoCAD SHX Text

8'' MINIMUM

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

GASKETED FASTENERS¾MIN. MIN. TWO FASTENERS PER SIDE

AutoCAD SHX Text

ROOFTOP EQUIPMENT FRAME

AutoCAD SHX Text

SECTION

AutoCAD SHX Text

FLASHING MEMBRANE

AutoCAD SHX Text

WOOD CURB

AutoCAD SHX Text

FLASHING RECEIVER

AutoCAD SHX Text

1'' MINIMUM BELOW TOP OF CURB

AutoCAD SHX Text

SEALING MATERIAL¾ MUST BE CONTINUOUS ON TOP OF THE CURB

AutoCAD SHX Text

FASTENERS

AutoCAD SHX Text

COUNTERFLASHING

AutoCAD SHX Text

BASE OF UNIT EXTENDS 1/2'' MINIMUM BEYOND TOP OF CURB

AutoCAD SHX Text

MECHANICAL UNIT, HOOD, ETC.

AutoCAD SHX Text

SHEET-METAL RECEIVER WITH REMOVABLE COUNTERFLASHING ¾ SEE NOTES 6

AutoCAD SHX Text

ADHERED MEMBRANE FLASHING

AutoCAD SHX Text

PREFABRICATED CORNER FLASHING PIECE AT EACH CORNER

AutoCAD SHX Text

1. THE CURBS, TOP WOOD NAILER AND SEAL STRIP ARE TO BE THE CURBS, TOP WOOD NAILER AND SEAL STRIP ARE TO BE SUPPLIED BY THE CURB MANUFACTURER. 2. WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE WHEN POSSIBLE, THE MECHANICAL UNITS SHOULD NOT BE SET UNTIL THE ROOF MEMBRANE AND FLASHING HAVE BEEN INSTALLED. 3. WHERE THE SKYLIGHT, SCUTTLE OR SMOKE VENT FRAME WHERE THE SKYLIGHT, SCUTTLE OR SMOKE VENT FRAME OVERLAPS THE BASE FLASHING AT LEAST 3 INCHES, THE REMOVABLE SHEET-METAL COUNTERFLASHING IS NOT REQUIRED. 4. NRCA RECOMMENDS DESIGNERS CONSIDER PERMANENT NRCA RECOMMENDS DESIGNERS CONSIDER PERMANENT INTERNAL OR EXTERNAL FALL-PROTECTION DEVICES AT ALL SKYLIGHTS. 5. REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS. 6. REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR COUNTERFLASHINGS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

PREMANUFACTURED MEMBRANE FLASHING

AutoCAD SHX Text INSTALL SEALANT OR SEALANT TAPE BETWEEN PIPE AND PREMANUFACTURED MEMBRANE FLASHING

AutoCAD SHX Text

PLUMBING VENT STACK

AutoCAD SHX Text

DRAWBAND

AutoCAD SHX Text

SEALANT

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

1. VENT STACKS AND OTHER PIPES SHOULD HAVE A MINIMUM OF 12 INCHES OF CLEARANCE ON ALL SIDES FROM VENT STACKS AND OTHER PIPES SHOULD HAVE A MINIMUM OF 12 INCHES OF CLEARANCE ON ALL SIDES FROM WALLS, CURBS AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING. SEE THE INTRODUCTION TO THE CONSTRUCTION DETAILS FOR ADDITIONAL INFORMATION. 2. NRCA RECOMMENDS FLASHINGS BE 8 INCHES HIGH; HOWEVER, NRCA IS AWARE PREMANUFACTURED BOOT NRCA RECOMMENDS FLASHINGS BE 8 INCHES HIGH; HOWEVER, NRCA IS AWARE PREMANUFACTURED BOOT FLASHINGS GENERALLY WILL NOT MEET THE HEIGHT REQUIREMENT. 3. REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT AND PLACEMENT. MECHANICALLY ATTACHED SYSTEMS GENERALLY HAVE SPECIFIC ATTACHMENT REQUIREMENTS FOR PENETRATION LOCATIONS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

BASE MEMBRANE ATTACHMENT AS REQUIRED FOR SPECIFIC SYSTEM ¾ SEE NOTE 3

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

MEMBRANE-COATED METAL PENETRATION POCKET ¾ SEE NOTES 3

AutoCAD SHX Text

NONSHRINK GROUT

AutoCAD SHX Text

HOT-AIR-WELDED MEMBRANE FLASHING

AutoCAD SHX Text OPTIONAL: WEATHERPROOF SHEET-METAL RAIN COLLAR OVERLAPPING PENETRATION POCKET WITH APPROPRIATE SEALANT (E.G., POLYURETHANE)

AutoCAD SHX Text

HOT-AIR-WELDED SEAM

AutoCAD SHX Text

VERIFY DEPTH WITH SEALANT MANUFACTURER

AutoCAD SHX Text

1. PENETRATION POCKETS ARE NOT THE PREFERRED FLASHING METHOD AT PENETRATIONS BECAUSE THEY PENETRATION POCKETS ARE NOT THE PREFERRED FLASHING METHOD AT PENETRATIONS BECAUSE THEY MAY BE A MAINTENANCE PROBLEM. 2. REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT AND PLACEMENT. MECHANICALLY ATTACHED SYSTEMS GENERALLY HAVE SPECIFIC ATTACHMENT REQUIREMENTS AT PENETRATION LOCATIONS. 3. REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR PENETRATION POCKETS.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

CROWN POURABLE SEALANT

AutoCAD SHX Text

AutoCAD SHX Text N.T.S.

W

FO

R T

B

LI

SS

8' ' M

IN

IM

U M

FL

AS

H

IN

G H

EI

G

H T

¾

¾

¾

¾

¾

¾

¾

¾

AutoCAD SHX Text

REVIEWED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DESIGNED BY:

AutoCAD SHX Text

SPEC. #

AutoCAD SHX Text W.O. #

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

NUMBER:

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

MARK

AutoCAD SHX Text

DATE

AutoCAD SHX Text

OF

AutoCAD SHX Text

DIRECTORATE OF PUBLIC WORKS FORT BLISS, TEXAS

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text A-104

AutoCAD SHX Text

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AS SHOWN

AutoCAD SHX Text M.A.A.

AutoCAD SHX Text 03/31/2026

AutoCAD SHX Text E.T.

AutoCAD SHX Text E.T.

AutoCAD SHX Text

BUILDING 2417 ROOF REPLACEMENT

AutoCAD SHX Text

DETAILS (CONTINUED)

AutoCAD SHX Text

AutoCAD SHX Text

THROUGH-WALL SCUPPER

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

PIPE SUPPORT

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text 10"X10" MIN. MEMBRANE PAD FULLY ADHERED TO ROOF MEMBRANE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

AutoCAD SHX Text

PIPE SUPPORT SET IN SEALANT - - SEE NOTE 2

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

1. THIS DETAIL IS DESIGNED TO ELIMINATE ROOF DAMAGE DUE TO EXPANSION AND CONTRACTION OF PIPES. THIS DETAIL IS DESIGNED TO ELIMINATE ROOF DAMAGE DUE TO EXPANSION AND CONTRACTION OF PIPES. 2. PIPE SUPPORT PROFILES VARY. REFER TO THE MANUFACTURER FOR LOAD CAPACITY. SPACE SUPPORTS PIPE SUPPORT PROFILES VARY. REFER TO THE MANUFACTURER FOR LOAD CAPACITY. SPACE SUPPORTS EVERY 6'-0" MIN. AND ALL CHANGES IN DIRECTION ON EACH SIDE OF TURN.

AutoCAD SHX Text

SEE EPDM-9 FOR CURB FLASHING

AutoCAD SHX Text REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR SHEET-METAL COVERS.

AutoCAD SHX Text THIS DETAIL IS DESIGNED TO ELIMINATE ROOF DAMAGE DUE TO EXPANSION AND CONTRACTION OF PIPES. PIPE SUPPORT PROFILES VARY.

AutoCAD SHX Text 2.

AutoCAD SHX Text 1.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

SET FASTENERS IN SEALANT

AutoCAD SHX Text

PIPE SUPPORT¾ PROFILES VARY

AutoCAD SHX Text GUTTER BRACKETS ARE RECOMMENDED TO BE AT LEAST ONE GAUGE HEAVIER THAN GUTTER STOCK.

AutoCAD SHX Text IN CLIMATES WHERE THE WINTER TEMPERATURE REMAINS BELOW FREEZING FOR EXTENDED PERIODS OF TIME, NRCA SUGGESTS INTERIOR DRAINS TO DRAIN THE ROOF.

AutoCAD SHX Text

ON BALLASTED SYSTEMS, A DRAINAGE BAR TO RETAIN BALLAST IS REQUIRED.

AutoCAD SHX Text 3.

AutoCAD SHX Text 2.

AutoCAD SHX Text

SEALANT WATER BLOCK

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text 1.

AutoCAD SHX Text 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾ OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text SHEET-METAL GUTTER¾THE FRONT OF THE GUTTER THE FRONT OF THE GUTTER SHOULD BE A MIN. 1'' LOWER THAN THE BACK TO ALLOW OVERFLOW. SEE THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR OTHER GUTTER SHAPES.

AutoCAD SHX Text

GUTTER BRACKET SUPPORT

AutoCAD SHX Text

STIFFENING BAR

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

FULLY ADHERED MEMBRANE FLASHING

AutoCAD SHX Text

SHEET-METAL EDGE FLASHING ¾ SEE NOTES 5

AutoCAD SHX Text

GUTTER SPACERS INSTALLED BETWEEN GUTTER BRACKETS

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

FIELD SHEET OR SEPARATE MEMBRANE SHEET EXTENDED BELOW BLOCKING

AutoCAD SHX Text REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR PERIMETER EDGE METAL.

AutoCAD SHX Text 4.

AutoCAD SHX Text

APPROX. 2'' (TYP.)

AutoCAD SHX Text REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT AND PLACEMENT. MECHANICALLY ATTACHED SYSTEMS GENERALLY REQUIRE SPECIFIC ATTACHMENT REQUIREMENTS FOR PERIMETER LOCATIONS.

AutoCAD SHX Text 5.

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

SHEET-METAL GRAVEL STOP ¾ SEE NOTES 3

AutoCAD SHX Text

FIELD SHEET EXTENDED BELOW BLOCKING

AutoCAD SHX Text 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾OVERALL THICKNESS TO OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text

SELF-ADHERING MEMBRANE FLASHING (EXTEND APPROX. 2'' BEYOND FLANGE)

AutoCAD SHX Text

APPROX. 2''

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

SEALANT WATER BLOCK

AutoCAD SHX Text REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS.

AutoCAD SHX Text REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR GRAVEL STOPS.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT AND PLACEMENT. MECHANICALLY ATTACHED SYSTEMS GENERALLY HAVE SPECIFIC ATTACHMENT REQUIREMENTS FOR PERIMETER LOCATIONS.

AutoCAD SHX Text 3.

AutoCAD SHX Text

PERIMETER EDGE- METAL FLASHING¾ SEE NOTES 3 AND 4

AutoCAD SHX Text

SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM)

AutoCAD SHX Text

FIELD SHEET EXTENDED BELOW BLOCKING

AutoCAD SHX Text 2 X 6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE¾ OVERALL THICKNESS TO MATCH INSULATION

AutoCAD SHX Text

SELF-ADHERING MEMBRANE FLASHING

AutoCAD SHX Text

APPROX. 2''

AutoCAD SHX Text

OPTIONAL: WOOD NAILER AND SHEET-METAL CLOSURE

AutoCAD SHX Text

BONDING ADHESIVE

AutoCAD SHX Text

SEALANT WATER BLOCK

AutoCAD SHX Text REFER TO THE INTRODUCTION OF THE CONSTRUCTION DETAILS CHAPTER FOR ALTERNATIVE BASE SECUREMENT OPTIONS.

AutoCAD SHX Text REFER TO THE ARCHITECTURAL METAL FLASHING SECTION OF THE NRCA ROOFING MANUAL: ARCHITECTURAL METAL FLASHING, CONDENSATION AND AIR LEAKAGE CONTROL, AND REROOFING FOR DESIGN, JOINERY AND SECUREMENT OPTIONS FOR PERIMETER EDGE METAL.

AutoCAD SHX Text 1.

AutoCAD SHX Text 2.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text REFER TO MANUFACTURERS' SPECIFICATIONS FOR SPECIFIC REQUIREMENTS FOR BASE MEMBRANE ATTACHMENT AND PLACEMENT. MECHANICALLY ATTACHED SYSTEMS GENERALLY HAVE SPECIFIC ATTACHMENT REQUIREMENTS FOR PERIMETER LOCATIONS.

AutoCAD SHX Text 3.

AutoCAD SHX Text

AutoCAD SHX Text

GUTTER WITH PERIMETER EDGE METAL

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

PIPE SUPPORT CURB AT PIPING ON MECH. EQUIPMENT

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

EMBEDED EDGE METAL FLASHING (GRAVEL STOP)

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

AutoCAD SHX Text

DRAINING PERIMETER EDGE METAL

AutoCAD SHX Text N.T.S.

AutoCAD SHX Text

INSULATION

AutoCAD SHX Text

SUBSTRATE

AutoCAD SHX Text

WALL

AutoCAD SHX Text

WALL

AutoCAD SHX Text

WOOD NAILER

AutoCAD SHX Text

TPO MEMBRANE

AutoCAD SHX Text

2" MIN.

AutoCAD SHX Text

WELDED SPLICE

AutoCAD SHX Text NOTE: 1. WOOD NAILER MUST BE INSTALLED TO MEET APPLICABLE BUILDING CODES OR 200 LINEAR 200 LB IN ANY GIVEN DIRECTION. 2.

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .