Attachment 2 - AF 66 - 29 JAN 24.xlsx

XLSX spreadsheet 29 KB Posted

Attached to
Cathodic Protection Beale AFB
Solicitation number
FA468624R0032
Issued by

About this file

This document is an Attachment 2 - AF 66 - 29 JAN 24.xlsx, which appears to be a submittal schedule for a federal contract opportunity. The related federal contract opportunity is for a Cathodic Protection System project at Beale AFB, with a Solicitation Number of FA468624R0032.

The key details include: The project is for a Cathodic Protection System for 7 water wells at Beale AFB, with a contract value between $300K - $500K. The NAICS code is 238190 Cathodic Protection Installation. Important dates include a site visit on 13 August 2024, RFI due on 15 August 2024, and proposal due on 21 August 2024. The project requires various technical submittals such as design drawings, specifications, test results, manuals, and other documentation. The document also lists the required submission dates and review process for the various submittal items.

View the file

Other files

File Type Posted
Solicitation Amendment - FA468624R00320002.pdf PDF
Solicitation Amendment FA468624R00320002 SF 30.pdf PDF
Pre-bid RFIs .xlsx XLSX spreadsheet
Solicitation Amendment - FA468624R00320001.pdf PDF
Attachment 9 - Sec L - 30 Jul 2024.docx DOCX document
Attachment 8 - Hold Harmless Agreement - Cathodic Protection Wells.docx DOCX document
Solicitation Amendment FA468624R00320001 SF 30.pdf PDF
Attachment 10 - Sec M - 30 Jul 24.docx DOCX document
Attachment 4 - Cathodic Protection AF Form 813 - 23 May 24.pdf PDF
Attachment 12 - Site Map- Utilities.pdf PDF
Solicitation - FA468624R0032 - signed.pdf PDF
Attachment 14 - Well Data -Table.JPG JPG image
Attachment 6 - AF 3052 Supplemental guidance.docx DOCX document
Attachment 11 - CONTRACTOR EAL 2024.xlsx XLSX spreadsheet
Attachment 8 - Hold Harmless Agreement - Cathodic Protection Wells.docx DOCX document
Attachment 3 - Site plan-CP direction - 29 Jan 24.xlsx XLSX spreadsheet
Attachment 7 - Past Performance Questionnaire - Cathodic Protection Wells.pdf PDF
Attachment 13 - Well CP as-built.pdf PDF
Attachment 5 - AF 3052 Cost Estimate Breakdown.xlsx XLSX spreadsheet
Attachment 1 - SON_27 Jun 24.pdf PDF
Attachment 10 - Sec M - 30 Jul 24.docx DOCX document
Attachment 9 - Sec L - 30 Jul 2024.docx DOCX document
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Submittal 1

SCHEDULE OF MATERIAL SUBMITTALSPROJECT NUMBERPROJECT NAMESOLICITATION /CONTRACT NUMBER
1135097Repair Cathodic Protection System at Well FieldsFA468624R0013
TO BE COMPLETED BY PROJECT ENGINEERTO BE COMPLETED BY CONTRACT ADMINISTRATOR
LINE NUMBERNote: 3 copies required per submittal. Government will retain all submittals. Provide an electronic copy for each submittal.CERTIF. OF COMPLIANCESHOP DRAWINGSCOLOR SELECTIONMANUFATURUR'S RECOMMENDATIONCATALOG DATAO&M RECOMMENDATIONSCALCULATIONSWARRANTYDRAWINGSREPORTTEST RESULTSREQUIRED SUBMISSION DATEDATE TO CONTRACTINGDATE TO CIVIL ENGINEERINGRETURN SUSPENSE DATESUBMITTAL NUMBERSAPPROVEDDISAPPROVEDCONTRACTOR SUBMITTALFINAL APPROVAL
GENERAL
Project Specific Form 66XNTP + 15
Construction ScheduleXNTP + 7
TCN Schedule (electronic required, hard copy optional)XNTP + 7
Contractor's Health, Safety, and Environment PlanXXNTP + 7
Contractor's QA/QC PlanXXX
Copy of Engineering License(s) of person or consultancy responsible for designXDesign
DESIGN
All submissions to be provided electronically unless noted.XxXXXXxXxNTP + 15PE STAMP REQ'D, NO HARD COPY
Roof Drain Storm Sewer Tie In
Wind Loading Diagrams for Roof
Structural Connection Details for Shear Walls
Structural Connection Details for Framing
Structural Connection Details for Blast Resistant Doors & Windows
HVAC Calculations
Sprinkler Layout
Fire Alarm Layout
Communications Layout
Technical SpecificationsXXXXNTP+45PE STAMP REQ'D, NO HARD COPY
DEMOLITION/ASBESTOS
Demolition Plan
Asbestoes Plan (IF NEEDED)XX
CIVIL
Soil Gradations for each type of soil used
Moisture-Density curve for each type of soil used
Nuclear Densometer Calibration
Soil Compaction Test Results for Utilities, Facilities & PavementXXXInstall+15
Storm Pipe
ARCHITECTURAL
Blast Resistant Doors and Frames
Door Hardware
Gypsum Board-Type X
Gypsum Board-Type X-Mold Resistant
Wood Paneling
Wood Chair Rails
Wood Ceiling Cloud
Sheet Vinyl Flooring
Rubber Base
Ceiling Tiles
Blast Resistant Window
Glazing
Solid Surface Countertops
Kitchen Cabinets
Garbage Disposal
Interior Paint
Exterior PaintNTP+45
Roofing System
Roofing Insulation
Roof Drains
Scuppers
Coping
Flashing
STRUCTURAL
Reinforcing Steel Drawings
Concrete Mix Design
Concrete Curing Compounds, Admixtures, Joint Sealants, Expansion Joints
Concrete Field Test Results
Reinforcing Steel Mill Certifications
Slump Test results & Concrete Truck Tickets (per truck)
7-Day Concrete Compressive Strength Test
28-Day Concrete Compressive Strength Test
Blast Resistant Window Attachment
MECHANICAL

PLUMBING

INTERIOR ELECTRICAL
Cables(electrical,comm,fire alarm)XXXNTP+7
SwitchesXXNTP+7
ReceptaclesXXXNTP+7
PanelsXXNTP+7
BreakersXXNTP+7
ConduitsXXX
Lighting Fixtures
Lighting UPS units (if req'd)
Communication System Outlets(incl jacks)
Communications patch panels
PA Speakers
Fire Alarm Devices (All)
Occupancy Sensors
Power Packs
EXTERIOR ELECTRICAL
Conduits (IF NEEDED)XXX
Transformer
Meter
Cables(med & low voltage)xXXXXXNTP+14
SwitchesxxNTP+14
ContactorsxNTP+14
PanelsNTP+14
BreakersxXxNTP+14
ControllerxXNTP+14
Junction CabinetXxXNTP+14
Heating MatNTP+14
CLOSEOUT
O&M maint data and maint manuals & Manufacturer's Warranty for Communications EquipmentXxXXInstall + 4
Factory and Field Test Certificates, Logs and Test ResultsxXXBefore Acceptance
Inspection LogbookxXxBefore Acceptance
As Builts (electronic in AutoCAD and hard copies on Mylar)XXFinal + 7