Attachment 1(a) - Drawings-Final 100pct 9-29-2021.pdf
PDF 2 MB Posted
- Solicitation number
- 697DCK-22-R-00004
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
z s e -1
-m
.d g n
/2
/2
:4
:2
A
M L o ri
D iV o n a
A
B
C
D
E
F
G
H
8 7 6 5 4 3 2 1
H
G
F
E
D
C
12345678
REVDRAWING NO
DATE JCN
APPROVED BY
ISSUED BY
CHECKED
DRAWN
DESIGNED
SUBMITTED BY
REVIEWED BY
FEDERAL AVIATION ADMINISTRATION
DEPARTMENT OF TRANSPORTATION
REV
DATE
APPROVED
DESCRIPTION JCN
DATE
REDLINE
APVD
A
NO.
PUMP
MANUFACTURER MODEL SERVICE
GPM
FLOW
FT H20
HEAD
RPM HP ELECTRICAL REMARKS
-P-2A
WATER
HOT
HEATING
335 105 1750 480/3/60Hz
15 -P-2B
WATER
HOT
HEATING
335 105 1750 480/3/60Hz
MIN EFF.
70%
70%
BASE PLATE
MOTOR
EQUIPMENT PAD
SUCTION DIFFUSER
ELBOW W/
BUILT-IN STRAINER
(TYP)
PUMP SCHEDULE
FLEX
CONNECTOR
(TYP)
FLR ONE ROOF
FLR ONE
BASEMENT
12" DIA12" DIA
TACO
TACO
SUCTION
END
FI SERIES
SUCTION
END
FI SERIES
MAINTENANCE PAD
CHECK
VALVE (TYP)
1'-0"
1'-6"
MASONRY FACE
x x x x x x3
E
X
IS
T
M A
T C
H
C L
R
CLR
2"
1"
CHIMNEY EQUIPMENT SUPPLIED
COORD PAD SIZE W/
P O
W E
R S
E R
V
IC
E B
U
IL
D
IN
G
ADMINISTRATION
WING
AUTOMATION
CONTROL WING
WING
INTERIM
WING
SUPPORT
OPERATIONS
KEY PLAN
BUILDING
SUPPORT
GENERAL NOTES:
SHEET NOTES:
A.
PRODUCTS OR BEGINNING CONSTRUCTION.
POTENTIAL BUILDING INTERFERENCES BEFORE ORDERING
FIELD VERIFY DIMENSIONS, CONNECTIONS, AND ANY
2 2
STORM COLLAR/FLASHING
SCREEN
RAIN CAP W/ BIRD
WIND RESISTANT
ANCHORS
FLOOR
C
M005
ATTACHED TO MASONRY WALL
RING SUPPORTS
C
M005 SCALE: 1/4" = 1' - 0"
EXISTING CHIMNEY COVER
B
M005 SCALE: 1/4" = 1' - 0"
BOILER ROOM ELEVATIONS
DRAIN
DOOR W/
CLEANOUT
AND PUMP TRIM.
PROVIDE NEW PIPING, GAUGES, VALVES, CONNECTIONS
AND SUPPORTS.
MAINTENANCE PAD AND ALL NECESSARY ANCHORS
CLEANOUT DOORS WITH DRAINS IN ASSEMBLY OR
ASSEMBLY TO INCLUDE RAIN CAPS, FLASHINGS,
FACILITY BOILER COMBUSTION REQUIREMENTS.
PROVIDE NEW CHIMNEY ASSEMBLIES BASED ON
AND FLASHING FOR CEILING PENETRATIONS.
PROVIDE MANUFACTURER RECOMMENDED FIRESTOPPING
D
M005 SCALE: NTS
MAINTENANCE PAD DETAIL
COVER TO FIT NEW CHIMNEY ASSEMBLY.
PROVIDE NEW OR RECONFIGURE EXISTING CHIMNEY
HIT-HY 200 ADHESIVE OR APPROVED EQUAL.
(TYP) EPOXIED INTO EXISTING SLAB W/ HILTI
BOND. #3 REBAR AT 12" OC AROUND PERIMETER
ROUGHEN PAD SURFACE TO 1/4" AMPLITUDE FOR
PROVIDE NEW MAINTENANCE PAD FOR CHIMNEYS.
D
M005
E D
M
IS
S
U E
D F
O R
ENGINEERING SERVICES
ENROUTE/FSS
ARTCC
ELEVATIONS AND SCHEDULE
MERGED HYDRONIC SYSTEMS REPLACEMENT
ADMINISTRATION WING BASEMENT
WAAUBURNSEATTLE
CALLEN R. COLLINSDOMINICK HUDSON
DH
DH
PROJECT ENGINEER MGR: ENGINEERING - SEATTLE
03/22/2021 1704390
ZSE-1704390-M005 A
DH 1704390PROJECT DRAWING UPDATE04/27/2021A
z s e -1
-m
.d g n
DRAWING PRODUCED ON WSA MICROSTATION SYSTEM
ATO - TECHNICAL OPERATIONS WESTERN SERVICE AREA
C O
N S
T R
U C
T
IO
N
H
W S
H
W S
| ZSE-1704390-G002 |
| ZSE-1704390-G003 |
| ZSE-1704390-G004 |
| zse-1704390-m001 |
| zse-1704390-m002 |
| ZSE-1704390-M005 |
File details come from the government source that posted it. Updated .