ATTACHMENT 11 EHRM Tier 1 Design Drawings - 2 of 3.pdf
PDF 9 MB Posted
- Attached to
- Y1BG--757-22-1-344-0002 EHRM Infrastructure Upgrades - Columbus, OH - Tier 1 (VA-21-00085439)
- Solicitation number
- 36C77622B0048
About this file
This is a solicitation for an Invitation for Bid for EHRM Infrastructure Upgrades in Columbus, Ohio. The solicitation is set aside for Service-Disabled Veteran-Owned Small Businesses and requires offerors to be verified in the Vendor Information Pages database. Technical questions are due by August 5th and responses will be provided through amendments to the solicitation posted on SAM.gov. A mandatory site visit will be held on July 28th. Electronic bids are due on August 16th and will be publicly read aloud on a conference line. Offerors must provide representations and certifications, past performance evaluations, and safety records. The contract will require background checks for employees. Ohio sales tax exemption forms must be completed for materials purchased for the project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CRW 39RGH
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES -
COLUMBUS, OH - TIER 1
6/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
ACC
No. REVISION DESCRIPTION DATE
FULLY SPRINKLERED
Veterans Health
Administration
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
1 ASI-0001 1/26/2022
EXISTING GRADE
NOTE:
DETECTABLE WARNING TAPE
CONCRETE ENVELOPE
A. WARNING TAPE SHALL BE IMPRINTED WITH THE
WORDS "WARNING - TELECOMMUNICATIONS CABLE
BELOW" AT NO MORE THAN 48" INTERVALS. TAPE
SHALL HAVE MINIMUM THICKNESS OF 0.004" AND SHALL
HAVE MINIMUM STRENGTH OF 1750 PSI TAPE SHALL
HAVE INTEGRAL MEANS OF DETECTION BY A METAL
DETECTOR WHEN THE TAPE IS BURIED 3 FEET DEEP
AND SHALL BE MADE OF MATERIALS RESISTANT TO
DEGRADATION CAUSED BY SOIL CONDITIONS.
4-WAY DUCT BANK
SCALE: NTS
M A
X
1'
6"
A S
R E
Q U
IR
E
D (2
4" M
IN
IM
U M
#4 REBAR (TYPICAL)
MASONRY LEVELING BLOCKS
AT BASE OF SPACERS AS NEEDED
BASE AND INTERMEDIATE SPACERS
(48" ON CENTER)
B. REFER TO TECHNOLOGY SITE PLAN FOR ADDITIONAL
INFORMATION INCLUDING INNER DUCT REQUIREMENTS.
TREE PRESERVATION NOTES
TREE PROTECTION DETAIL
NOT TO SCALE
ROOT PRUNING NOTES:
C. STANDARD DUCT BANK CONSISTS (4) 4" CONDUITS, WITH MULE
TAPE AND LOCATOR WIRE INSTALLED IN EACH CONDUIT
STANDARD DUCT BANK CONSISTS OF (4) 4"
CONDUITS, WITH MULE TAPE AND LOCATOR
WIRE INSTALLED IN EACH CONDUIT
DETAILS
GS-004
CONCRETE
ASPHALT
GRAVEL
ASPHALT
BENCH
BENCH
4"
4"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2" 2"
2" 2"
2"
2" 2"
2" (TYP.)
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2" 2" 2"
2"
2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2" 2"
2"
2"
2"
2"
2"
2"
2"
2" 2"
2" 2"
2" 2"2"
2" 2"2"
2"2"
2"
2"
2"
2"
2"
2" 2"2"
2"
2" 2"
2" 2"
2"
2"
2" 2"
2"
2"
2"
2"
2"
2"
2"2"
2"
2"2"
2"
2" 2"
2"
2" 2"
2"2"
2" MULTI
2" MULTI
2" MULTI
2" MULTI
2" MULTI
2"
2"
2"
2"
1" YEW (TYP.)
2"
2"
2"
2"
2" 2"
2" 2"
2"
2"
2" 2"
2" 2"
2" 2"
2" 2"
2"
2" 2"
2"
2" 2"
2"
2" 2"
2" 2"
2" 2"
2"
2"
2" 2"
2" 2"
2"
2"
2"
2"
2"
2"
2"2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2" 2"
2"
2"2" 2" 2"
2"2"
4"
4"
4"
4"
4"
4"
4"
2"
2"
2"2"
2"
2"
EMPTY
PER PLAN
NOT FOUND
UNABLE TO DETERMINE POINT OF
TERMINATION
4"
4" 4"
H
MW
BP
T
VT
EM
PE
SCOPE BOUNDARY
25'-0" SAFETY SETBACK
MONITORING WELL & 20'-0" ACCESS CLEARANCE
RELOCATED PHOTOVOLTAIC ARRAY
BUILDING FOOTPRINT
LANDSCAPED AREA
RAISED PLANTER BOX (BOLLARD ALTERNATIVE)
HARDSCAPED AREA
MW
SECURITY BOLLARD - LIGHTED
STORMWATER DRAIN
SECURITY BOLLARD - REMOVABLE
ACCESSIBLE RAMP
LOADING ZONE / FIRE LANE
STABILIZED DECORATIVE ROCK
CONCRETE PAVERS
ACC
A
EC
WASHINGTON
WASHINGTON
WASHINGTON
W
ASHINGTON
W
ASHINGTON
N J
A M
E S R
D
N J
A M
E S R
D
N J
A M
E S R
D th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t
00 00
11 11 o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t o n e in c h o n e fo o t
00 00
22 22 th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t
00 00 22 22 o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t o n e h a lf in c h o n e fo o t
00 00 44 44 th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t th re e e ig h th s in c h o n e fo o t
00 00 44 44 o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t
00 00 44 44
88 88 o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t o n e e ig h th in c h o n e fo o t
00 00 44 44
88 88
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/9
/2
:3
:3
P
M
ARCHITECTURAL SITE PLAN
ECO 10 39BKM
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
Chalmers P. Wylie VA Ambulatory Care Center 420 North James Road Columbus, OH 43219
AS-001
SITE PLAN LEGEND
1" = 60'-0"
EXISTING SITE PLAN1
No. REVISION DESCRIPTION DATE
N
UE
OE
M/G 400A/3P
M/G 400A/3P
C
PC
R
TS
T
100/3
100/3/70
100/3/70/1
100/3/CB
PP
J
GF
OR
OR
OR
EPO
AM
VM
DM
ST
KK
GFR
M
SPD
R
LP1
A1
LIGHT FIXTURE, CEILING MOUNTED
a
LIGHTING TRACK WITH TRACK LIGHT FIXTURES
LIGHT FIXTURE, POLE MOUNTED
LIGHT FIXTURE, WALL MOUNTED
EMERGENCY BATTERY PACK LIGHT FIXTURE,
WALL MOUNTED
EMERGENCY BATTERY PACK LIGHT FIXTURE,
CEILING MOUNTED
EXIT SIGN, WALL MOUNTED, FACE/ARROWS AS INDICATED
EXIT SIGN, CEILING MOUNTED, FACE/ARROWS AS INDICATED
EMERGENCY LIGHT FIXTURE, CEILING MOUNTED
A1E a
A1 a
A1
A1
X1E
X1E
Y1E
Y1E
HOMERUN TO PANELBOARD, ARROWS INDICATE
NUMBER OF CIRCUITS, TICK MARKS INDICATE
NUMBER OF CONDUCTORS. DESIGNATIONS ARE
PANELBOARD AND CIRCUIT NUMBERS.
UNSWITCHED HOT CONDUCTORS SHOWN LEADING
NEUTRAL CONDUCTOR
NEUTRAL CONDUCTOR
SWITCHED HOT CONDUCTORS SHOWN TRAILING
GROUND CONDUCTOR
EQUIPMENT GROUNDING CONDUCTOR IN RACEWAY
ISOLATED GROUNDING CONDUCTOR IN RACEWAY
CONCEALED RACEWAY
EXPOSED RACEWAY
RACEWAY TURNING DOWN
RACEWAY TURNING UP
EQUIPMENT TERMINATION
LOW VOLTAGE CABLE (NOT ROUTED IN CONDUIT)
LIGHT FIXTURE, BOLLARDA1
RECEPTACLE, SIMPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DOUBLE-DUPLEX, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, CEILING MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, SPECIAL PURPOSE
RECEPTACLE, TWIST-LOCK
RECEPTACLE, DUPLEX, FLOOR MOUNTED, NEMA 5-20R, UNO
RECEPTACLE, DUPLEX, DROP CORD, NEMA 5-20R, UNO
RECEPTACLE, MOUNTED 6" ABOVE COUNTER,
TYPE AS INDICATED ABOVE
RECEPTACLE DESIGNATIONS AS FOLLOWS:
SWITCH, SINGLE POLE
SWITCH DESIGNATIONS AS FOLLOWS:
OCCUPANCY SENSOR, CEILING MOUNTED
POWER PACK FOR LIGHTING CONTROL
JUNCTION BOX
RECEPTACLE ON EMERGENCY POWER
RECEPTACLE, ISOLATED GROUND TYPE
MULTI-OUTLET, SURFACE RACEWAY, 24" ON CENTER,
NEMA 5-20R, UNO
SWITCHBOARD, MOTOR CONTROL CENTER OR DISTRIBUTION
PANELBOARD ON HOUSEKEEPING PAD
PANELBOARD, RECESS MOUNTED
PANELBOARD, SURFACE MOUNTED
TRANSFORMER
DISCONNECT SWITCH, NON-FUSED, 100/3 INDICATES
AMPERES/POLES, CB = CIRCUIT BREAKER TYPE
DISCONNECT SWITCH, FUSED, 100/3/70 INDICATES
AMPERES/POLES/FUSE, CB = CIRCUIT BREAKER TYPE
COMBINATION DISCONNECT SWITCH WITH MOTOR STARTER
100/3/70/1 INDICATES AMPERES/POLES/FUSE/ NEMA STARTER
SIZE, NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
MAGNETIC MOTOR STARTER, NEMA SIZE AS NOTED,
3-POLE, UNO
CONTACTOR
PHOTOCELL
RELAY
TIME SWITCH
LOW-VOLTAGE TRANSFORMER
PUSH BUTTON, TYPE AS NOTED
VARIABLE FREQUENCY DRIVE WITH DISCONNECT SWITCH
100/3/70 INDICATES AMPERES/POLES/FUSE SIZE,
NF = NON-FUSED, CB = CIRCUIT BREAKER TYPE
UNDERGROUND ELECTRIC LINE
MULTI-SERVICE FLOOR BOX/POKE-THRU WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
CABINET, RECESS MOUNTED
CABINET, SURFACE MOUNTED
RECEPTACLE, DUPLEX, GROUND-FAULT CIRCUIT
INTERRUPTER, NEMA 5-20R, UNO
MULTI-SERVICE POWER POLE WITH POWER/DATA,
TYPE AS NOTED AND/OR SCHEDULED
OVERHEAD ELECTRIC LINE
MUSHROOM TYPE PUSH BUTTON, TYPE AS NOTED
TRANSFER SWITCH, RATINGS AS INDICATED
ATS = AUTOMATIC TRANSFER SWITCH
TX#
600AF
3P
500AT
400AS
3P
225AF
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
275KW STANDBY
480Y/277V, 3PH, 4W
GENERATOR, NON-SEPARATELY DERIVED
SOURCE, TYPE AND RATINGS AS INDICATED
DRAWOUT CIRCUIT
BREAKER, RATINGS
AS INDICATED
600AF
3P
500AT
CIRCUIT BREAKER,
RATINGS AS
INDICATED
LPS-R
FUSED DISCONNECT
SWITCH, RATINGS
AS INDICATED
400AS
3P
225AF
LPS-R
COMBINATION FUSED
SWITCH AND STARTER,
RATINGS AS
PANELBOARD,
SINGLE-SECTION,
RATINGS PER
SCHEDULES
PANELBOARD,
MULTI-SECTION,
RATINGS PER
SCHEDULES
NEMA 1
AMMETER
VOLTMETER
COMBINATION DIGITAL
SHUNT-TRIP RELAY
KIRK-KEY INTERLOCK
GROUND-FAULT RELAY
UTILITY METER
RELAY
SURGE PROTECTION
AMMETER/VOLTMETER
DEVICE
AUTOMATIC TRANSFER SWITCH WITH BYPASS
TYPE AND RATINGS AS INDICATED
VARIABLE FREQUENCY
DRIVE WITH
DISCONNECT, RATINGS
GROUND CONNECTION
POTENTIAL TRANSFORMER
CURRENT TRANSFORMER
GROUND CONNECTION
WITH TEST WELL
CONTACT, OPEN
CONTACT, CLOSED
MOTOR
FEEDER TAGCAPACITOR
SURGE ARRESTER
HEATER
225A 3P
NEMA 1
INDICATED
COMBINATION CIRCUIT
BREAKER AND
STARTER, RATINGS AS
INDICATED AS INDICATED
225A 3P
200A 3P
ATS#
200A 3P
ATS#
TRANSFORMER
TX#
TRANSFORMER,
SHIELDED
200A DEAD-FRONT ELBOW
600A DEAD-FRONT ELBOW
DEAD-FRONT SPLITTER
FAULT INDICATOR
LIGHTNING PROTECTION AIR TERMINAL
LIGHTNING PROTECTION CABLE CONNECTION
LIGHTNING PROTECTION GROUND ROD
LIGHTNING PROTECTION CONDUCTOR
MTS = MANUAL TRANSFER SWITCH
LIGHTNING PROTECTION SYMBOLS
ELECTRICAL ONE-LINE DIAGRAM SYMBOLS
OS# = CEILING MOUNTED OCCUPANCY SENSOR, REFER
TO OCCUPANCY SENSOR AND SWITCH SCHEDULE
2 = TWO-POLE WALL SWITCH
3 = THREE-WAY WALL SWITCH
4 = FOUR-WAY WALL SWITCH
D = DIMMER SWITCH
OS# = OCCUPANCY SENSOR WALL SWITCH, REFER
TO OCCUPANCY SENSOR AND SWITCH SCHEDULE
P = SINGLE-POLE, SINGLE-THROW PILOT LIGHT
WALL SWITCH
K = KEYED WALL SWITCH
M = MOTOR RATED SWITCH
WP = WEATHER PROOF SWITCH AND COVER
C = CLOCK HANGER
E = EMERGENCY POWER
GF = GROUND FAULT CIRCUIT INTERRUPTER
IG = ISOLATED GROUND
S = SWITCHED
TR = TAMPER RESISTANT
WP = WEATHER PROOF COVER
WR = WEATHER RESISTANT
XP = EXPLOSION PROOF
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULE
Y1E = LIGHT FIXTURE TYPE "Y1E" REFER TO LIGHT
FIXTURE SCHEDULE
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
X1E = LIGHT FIXTURE TYPE "X1E" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
A1E = LIGHT FIXTURE TYPE "A1E" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
A1 = LIGHT FIXTURE TYPE "A1" REFER TO LIGHT
FIXTURE SCHEDULE
a = SWITCHED BY SWITCH "a"
NL = NIGHT LIGHT
= ARROW INDICATES AIMING DIRECTION
LIGHTING SYMBOLS
POWER EQUIPMENT SYMBOLS
WIRING DEVICE SYMBOLS
CIRCUITING SYMBOLS
ES EMERGENCY SHUNT RELAY
CU
MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT
PLUMBING PLAN NOTE CALL OUT
ELECTRICAL, TECHNOLOGY OR FIRE ALARM
PLUMBING EQUIPMENT DESIGNATION
EQUIPMENT DESIGNATION TAG
OWNER FURNISHED, CONTRACTOR INSTALLED
EQUIPMENT DESIGNATION
NEW WORK TO EXISTING WORK CONNECTION POINT
DETAIL REFERENCE
SECTION CUT DESIGNATION
ELECTRICAL: (AFF, AFG UNLESS NOTED OTHERWISE)
PLAN NOTE CALL OUT
EP-101
EP-101
M (CONT'D)
MV MEDIUM VOLTAGE
MVA MEGAVOLT-AMPERE
MW MEGAWATT
AUDIBLE APPLIANCES (CENTERLINE) 84"
ALARMS (TOP) 48"
ANNUNCIATOR PANELS (TOP) 48"
CLOCK OUTLETS (CENTERLINE) 84"
CONTROLS (TOP) 48"
EXIT SIGNS (WALL-MOUNTED, BOTTOM) 80"
FIRE ALARM ANNUNCIATOR PANEL (DISPLAY) 60"
FIRE ALARM BELL (EXTERIOR) 120"
FIRE ALARM CONTROL PANEL/UNIT (DISPLAY) 60"
INTERCOM (AFEA ONLY) 36"
INTERCOMS (TOP) 48"
PANELS & PANELBOARDS (TOP) 72"
PULL STATIONS (TOP) 48"
PHOTOCELLS 144"
RECEPTACLES (BOTTOM) 18"
RECEPTACLES, EXTERIOR (BOTTOM) 24"
RECEPTACLES, GARAGES (BOTTOM) 26"
RECEPTACLES IN EQUIPMENT ROOMS (TOP) 48"
RECEPTACLES ABOVE COUNTERTOPS (TOP) 44"
REMOTE INDICATING LIGHT, EQUIPMENT ROOMS (TOP) 48"
REMOTE INDICATING LIGHT, FINISHED AREAS (TOP) CEILING
SAFETY SWITCHES & STARTERS 48"
SWITCHES (TOP) 48"
TELEPHONE/DATA/TV OUTLETS (BOTTOM) 18"
VISIBLE APPLIANCES (CENTERLINE) 84"
X
W
V
U
T
S
R
ANNOTATION STANDARD MOUNTING HEIGHTS
P
O
N
M
L
K
J
I
H
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FABL FIRE ALARM BELL
FABX FIRE ALARM BOX
FACP FIRE ALARM CONTROL PANEL
FC FOOTCANDLE
FI FILM ILLUMINATOR
FIXT FIXTURE
FLA FULL LOAD AMPS
FLEX FLEXIBLE METALLIC CONDUIT
FLUOR FLUORESCENT
FO FIBER-OPTIC
FP FIRE PROTECTION
FT FEET OR FOOT
FVNR FULL VOLTAGE NON-REVERSING
FVR FULL VOLTAGE REVERSING
G
F
E
D
EC EMPTY CONDUIT
EG EQUIPMENT GROUND
EL ELEVATION
ELEC ELECTRIC OR ELECTRICAL
ELEV ELEVATOR
EMCP EMER. MONITORING CONTROL PANEL
EMER EMERGENCY
EMI ELECTROMAGNETIC INTERFERENCE
EMT ELECTRICAL METALLIC TUBING
ENCL ENCLOSURE
EPO EMERGENCY POWER OFF
ESMT EASEMENT
ETD EXISTING TO BE DEMOLISHED
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
EXIST EXISTING
DB DECIBEL OR DIRECT BURIAL
DC DIRECT CURRENT
DCP DIMMER CONTROL PANEL
DEG C DEGREES CELSIUS
DEG F DEGREES FAHRENHEIT
DEMO DEMOLITION
DIAG DIAGRAM
DISC DISCONNECT
DISTR DISTRIBUTION
DISTR PNL DISTRIBUTION PANEL
DN DOWN
DPDT DOUBLE POLE, DOUBLE THROW
DPST DOUBLE POLE, SINGLE THROW
DRSW DOOR SWITCH
DS DISCONNECT SWITCH
DWG DRAWING
C CONDUIT
CAP CAPACITY
CAT CATALOG
CATV COMMUNITY ANTENNA TELEVISION
CCR CONTROL CONTACTOR
CCTV CLOSED CIRCUIT TELEVISION
cd CANDELA
CD CONSTRUCTION DOCUMENTS
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/
CONTRACTOR INSTALLED
CF/OI CONTRACTOR FURNISHED/
OWNER
CFE CONTRACTOR FURNISHED
EQUIPMENT
CHW CHILLED WATER
CHWP CHILLED WATER PUMP
CKT CIRCUIT
CKT BRKR CIRCUIT BREAKER
CLF CURRENT LIMITING FUSE
CLG CEILING
CMU CONCRETE MASONRY UNIT
COAX COAX CABLE
COMM COMMUNICATION
CONC CONCRETE
CONT CONTINUE
CONTR CONTRACTOR
COORD COORDINATE
CPT CONTROL POWER TRANSFORMER
CRI COLOR RENDERING INDEX
CT CURRENT TRANSFORMER
CTV CABLE TELEVISION
CU COPPER
CU FT CUBIC FEET
C
B
A
ABBREVIATIONS
UFD UNDERFLOOR DUCT
UGND UNDERGROUND
UL UNDERWRITERS LABORATORY
UNO UNLESS NOTED OTHERWISE
UPS UNINTERRUPTIBLE POWER SUPPLY
UTIL UTILITY
V VOLT
VA VOLT AMPERE
VAR VOLT AMPERE REACTIVE
VCM VERTICAL CABLE MANAGER
VFD VARIABLE FREQUENCY DRIVE
VOLT VOLTAGE
TC TIME CLOCK
TEL TELEPHONE
TP TWISTED PAIR
TPS TWISTED PAIR SHIELDED
TTB TELEPHONE TERMINAL BOARD
TV TELEVISION
TYP TYPICAL
RCP REFLECTED CEILING PLAN
RCPT RECEPTACLE
REC RECESSED
REQD REQUIRED
RGS RIGID GALVANIZED STEEL
RM ROOM
RMS ROOT MEAN SQUARE
RU RACK UNIT
N NEUTRAL
NA NOT APPLICABLE
NEC NATIONAL ELECTRICAL CODE
NEMA NATIONAL ELECTRICAL
MANUFACTURERS ASSOCIATION
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NL NIGHT LIGHT
NO NORMALLY OPEN
NS NO SCALE
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OL OVERLOAD
MATV MASTER ANTENNA TELEVISION SYSTEM
MAX MAXIMUM
MC METAL-CLAD
MCA MINIMUM CIRCUIT AMPS
MCB MAIN CIRCUIT BREAKER
MCC MOTOR CONTROL CENTER
MDP MAIN DISTRIBUTION PANEL
MECH MECHANICAL
MG MOTOR GENERATOR
MH MANHOLE
MIN MINIMUM
MOCP MAXIMUM OVERCURRENT PROTECTION
MLO MAIN LUGS ONLY
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTS MANUAL TRANSFER SWITCH
KV KILOVOLT
KVA KILOVOLT AMPERE
KVAH KILOVOLT AMPERE PER HOUR
KVAR KILOVOLT AMPERE REACTIVE
KW KILOWATT
KWH KILOWATT HOUR
KWHM KILOWATT HOUR METER
JB OR J-BOX JUNCTION BOX
XFER TRANSFER
XFMR TRANSFORMER
XP EXPLOSION PROOF
LED LIGHT EMITTING DIODE
LF LINEAR FEET (FOOT)
LM LUMEN
LP LIGHT POLE
LPS LOW PRESSURE SODIUM
LRA LOCKED ROTOR AMPS
LTCP LOCAL TEMPERATURE CONTROL PANEL
LT LIGHT
LTG LIGHTING
LTG PNL LIGHTING PANEL
LTNG LIGHTNING
LV LOW VOLTAGE
W WATT
WH WATER HEATER
WP WEATHERPROOF
IESNA ILLUMINATION ENGINEERING
SOCIETY OF NORTH AMERICA
IG ISOLATED GROUND
IMC INTERMEDIATE METAL CONDUIT
INCAND INCANDESCENT
IR INFRARED
IWH INSTANTANEOUS WATER HEATER
G OR GND GROUND OR GENERATOR
GEN GENERATOR
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GTB GROUND TERMINAL BOX
SCC SHORT CIRCUIT CAPACITY
SES SERVICE ENTRANCE SECTION
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SHT SHEET
SI INTERNATIONAL SYSTEM OF UNITS
SPEC SPECIFICATION
SPST SINGLE POLE, SINGLE THROW
SURF SURFACE
SW SWITCH
SWBD SWITCHBOARD
SWGR SWITCHGEAR
P POLE
PA PUBLIC ADDRESS
PB PANELBOARD, PULL BOX, OR
PUSHBUTTON
PBPU PREFABRICATED BEDSIDE PATIENT UNIT
PCB POLYCHLORINATED BIPHENYL
PEC PHOTOELECTRIC CELL
PED PEDESTAL
PEND PENDANT
PF POWER FACTOR
PH PHASE
PNL PANEL
POD POWER OPERATED DAMPER
POE POWER OVER ETHERNET
PP PATCH PANEL
PT POTENTIAL TRANSFORMER
PTRV POWER TYPE ROOF VENTILATION
PVC POLYVINYL CHLORIDE (PLASTIC)
PWR POWER
1P SINGLE POLE
1PH SINGLE-PHASE
3P THREE POLE
3PH THREE-PHASE
3W THREE WIRE
4W FOUR WIRE
A/C AIR CONDITIONING
A/E ARCHITECT/ENGINEER
AAP ALARM ANNUNCIATOR PANEL
AC ALTERNATING CURRENT OR
ARMORED
ACC ACCESSIBLE
ADDL ADDITIONAL
ADJ ADJACENT, ADJOINING
ADO AUTOMATIC DOOR OPENER
AF AMPERE FRAME OR AMP FUSE
AFC ABOVE FINISHED COUNTER,
AUTOMATIC FREQUENCY
CONTROL, OR AVAILABLE FAULT
CURRENT
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AH AMPERE HOUR
AHJ AUTHORITY HAVING JURISDICTION
AIC AMPERE INTERRUPTING CAPACITY
ALT ALTERNATE
AMB OR A AMBIENT
AMP AMPERE
ARCH ARCHITECT
ASC AMPS SHORT CIRCUIT
AT AMPERE TRIP
ATS AUTOMATIC TRANSFER SWITCH
AUTO AUTOMATIC
AV AUDIO VISUAL
HCM HORIZONTAL CABLE MANAGER
HID HIGH INTENSITY DISCHARGE
HOA HAND-OFF-AUTOMATIC
HP HORSEPOWER
HT HEIGHT
HZ HERTZ
BAT BATTERY
BC BARE COPPER
BD BOARD
BFF BELOW FINISH FLOOR
BIL BASIC INSULATION LEVEL
BLDG BUILDING
BLK BLOCK
BPIP BOILER PLANT INSTRUMENTATION
PANEL
BRKR BREAKER
BYP BY PASS
IC INSULATION CONTACT
1. ELECTRICAL PLANS AND SECTIONS ARE INTENDED TO
ACCURATELY ILLUSTRATE THE SCOPE OF WORK, BUT ARE STILL
DIAGRAMMATIC IN NATURE.
2. ELECTRICAL DRAWINGS DO NOT SHOW ALL ACCESSORIES TO
BE INSTALLED. THE CONTRACTOR IS RESPONSIBLE FOR
ENSURING THAT ALL SYSTEMS ARE FULLY FUNCTIONAL AND
COMPLIANT WITH APPLICABLE CODES.
3. ELECTRICAL DRAWINGS REFLECT COORDINATION EFFORTS
WITH BUILDING DISCIPLINES. HOWEVER, COORDINATION WITH
OTHER TRADES IS REQUIRED.
4. ALL UPS(S) PROVIDED IN INDIVIDUAL TELECOMMUNICATIONS
ROOMS SHALL BE BACNET COMPATIBLE AND PROVIDE THE
FOLLOWING INFORMATION:
A. UPS STATUS
B. ROOM TEMPERATURE
C. ROOM HUMIDITY
GENERAL NOTES
5. PROVIDE MGE REMOTE ALARM STATUS PANEL IN THE NEW
URGENT CARE WING TO MONITOR APC SYMMETRA PX.
COORDINATE EXACT MOUNTING LOCATION WITH VA PRIOR TO
BID.
6. PROVIDE AP9613 RELAY CARD FOR USE WITH APC SYMMETRA
PX AND MGE REMOTE ALARM STATUS PANEL.
7. SEE GENERAL SHEETS FOR ADDITIONAL INFORMATION
REGARDING SCHEDULE AND PHASING REQUIREMENTS.
SCHEDULE WORK TO MINIMIZE DISRUPTION OF SERVICES.
8. COORDINATE SCHEDULE WITH THE CONTRACTING OFFICER'S
REPRESENTATIVE (COR) BEFORE THE START OF WORK.
9. PANELBOARDS AND OTHER ELECTRICAL EQUIPMENT
REQUIRE SHUTDOWN. COORDINATE SERVICE SHUT-DOWN
FOR ALL EQUIPMENT WITH THE COR.
10. MULTI-GANG BACKBOXES FOR DIFFERENT VOLTAGES AND
TYPES OF EMERGENCY AND NORMAL BRANCH WIRING
DEVICES SHALL HAVE DIVIDERS BETWEEN
DEVICES/VOLTAGES.
11. UPDATE ALL PANELBOARD SCHEDULES AFFECTED AT THE
COMPLETION OF THE PROJECT.
12. CONTRACTOR SHALL METER PANELBOARDS INDICATED IN
THE DRAWING SET FOR A MINIMUM OF 30 DAYS IN
ACCORDANCE WITH ARTICLE 220.87 OF THE 2020 NATIONAL
ELECTRICAL CODE. THE MAXIMUM METERED DEMAND PLUS
125 PERCENT SHALL NOT EXCEED THE PANELBOARD RATING.
IF CALCULATED LOAD EXCEEDS THE PANELBOARD RATING,
CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:3
A
M
ELECTRICAL LEGEND
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-000
ACC
Z Y X W V U
T S R Q P O N M L K J H
G F E D C B A
7.3
M A
T C
H L
IN
E M
A T
C H
L
IN
E
AREA A
AREA B
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:3
A
M
REFERENCE PLAN - ACC - LEVEL 1
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-101
ACC
N
3/64" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 11
A
-E -1
A
A
-E -1
B
A
-E -1
A
A
-E -1
B
E-401A
E-401A
E-401A
E-401A
Z Y X W V U
T S R Q P O N M L K
7.3
TELECOM
1A457
TELECOM
1A024
TELECOM
1A106
TELECOM
1A014
E-401A
E-401A
E-401A
E-401A
115115
116116
Electrical Room
1A360 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:3
A
M
REFERENCE PLAN - ACC - LEVEL 1 - AREA
A
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-101A
ACC
N
1/16" = 1'-0"
REFERENCE PLAN ACC - LEVEL 1 - AREA A1
ELECTRICAL KEYNOTES
115 EXISTING MAIN ELECTRICAL SERVICE GROUND BAR IN ELECTRICAL ROOM 1A360. FIELD VERIFY
LOCATION AND PROVIDE BONDING BETWEEN EXISTING ELECTRICAL SERVICE GROUND BAR
AND MAIN TELECOMMUNICATION GROUND BUSBAR (TMGB-4A201) IN SERVER ROOM 4A201.
PROVIDE GROUNDING CONDUCTORS AND BONDING ACCORDING TO TIA 607-C. REFER TO
DETAIL 1/E-501 FOR ADDITIONAL NOTES.
116 FIELD VERIFY BONDING CONDUCTOR PATH PRIOR TO BID.
117 BONDING CONDUCTOR CONTINUATION TO TELECOMMUNICATION GROUND BAR (TMGB-4A201)
IN SERVER ROOM 4A201. COORDINATE WITH TELECOMMUNICATION CABLE ROUTING TO
SERVER ROOM.
E-401B
E-401B
E-401B
J H
G F E D C B A
7.3
E-401B
E-401B
E-401B
TELECOM
1B006
TELECOM
1B002
DATA
1B609 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:4
A
M
REFERENCE PLAN - ACC - LEVEL 1 - AREA
B
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-101B
ACC
N
1/16" = 1'-0"
REFERENCE PLAN ACC - LEVEL 1 - AREA B1
E-101C
E-101C
DATA RM
Electrical
DATA RM
MDP
LP1
LP2
ETD
ETD
ETD
ETD
DATA RM
105106
TGB-106
107107
LP1
LP1
LP1
MDP
37,39,41
MDP
38,40,42
LP2 (E)
LP1 (E)
MDP (E)
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
4/
0:
4:
A
M
REFERENCE PLAN - ENGINEERING
BUILDING (A) - LEVEL 1
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-101C
ACC
N
1/8" = 1'-0"
REFERENCE PLAN - ENGINEERING BUILDING (A) - LEVEL 11
N
1/4" = 1'-0"
ENGINEERING BUILDING (A) - DATA ROOM 106 - DEMO2
N
1/4" = 1'-0"
ENGINEERING BUILDING (A)- DATA ROOM 106 - NEW3
ELECTRICAL KEYNOTES
101 DEMOLISH EXISTING RACK MOUNTED UPS.
105 PROVIDE NEW 20A RACK-MOUNTED UPS. BASIS OF DESIGN EATON BLADEUPS ( ZC0517700110000).
UPS SHALL SUPPLY A MINIMUM OF 20 MINUTES RUN TIME OF ITS CAPACITY.
106 PROVIDE TWO (2) NEW VERTICAL RACK-MOUNTED 208Y/120V, 3-PHASE, 20A INPUT POWER
DISTRIBUTION UNITS (PDU) PER RACK. BASIS OF DESIGN CHATSWORTH ECONNECT PDU
[PART#:L2-1N0G3, (30)C13, (6) C19]. REFER TO SHEET E-502 FOR PDU CONNECTION TO RACK
MOUNTED UPS, ZONE PDU'S AND OR 208Y/120V L21-20R RECEPTACLE DETAILS.
107 PROVIDE NEW 208V, 20A, 3-PHASE L21-20R RECEPTACLE TO SERVE POWER TO RACK MOUNTED UPS AND VERTICAL MOUNTED PDU ON ONE SIDE OF RACK. REFER TO DETAIL 1/E-502 FOR PDU
ARRANGEMENT IN TELECOMMUNICATION RACK.
114 PROVIDE NEW COPPER GROUND BAR ACOORDING TO DESIGN SPECIFICATIONS. BOND GROUND BUSBAR TO EXISTING BUILDING ELECTRICAL SERVICE GROUND BAR (REFERENCE THE BUILDING
GROUND SCHEMATIC RISER DIAGRAM ON 6/E-501). PROVIDE GROUNDING CONDUCTORS AND
BONDING ACCORDING TO TIA 607-C.
119 PROVIDE SECURITY CAMERA - INDOOR HD PTZ DOME SURVEILLANCE CAMERA, 12X OPTICAL ZOOM WITH AUTOFOCUS, 10X DIGITAL ZOOM, 1080P RESOLUTION AT 35/30 FRAMES PER SECOND, H.264 STREAM. IP51 RATED AGAINST DUST AND DRIPPING WATER (SUITABLE FOR SPRINKLER
ACTIVATION CONDITIONS), POWER-OVER-ETHERNET (MAX 13 WATTS), 1/2.3" CMOS SENSOR,
3.8-42.99MM FOCAL LENGTH, F1.4-F2.1 VARIABLE MAXIMUM APERTURE, 360° PAN, 180° TILT.
FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ALL NECESSARY POWER SUPPLIES,
SURGE PROTECTOR, MOUNTS AND WIRING FOR POWER, DATA, AND CONTROL FOR A COMPLETE
INSTALLATION. COORDINATE INSTALLATION LOCATION WITH VA.
122 PROVIDE BONDING TO THE NEAREST STEEL COLUMN. GROUNDING/ BONDING CONDUCTORS
SHALL COMPLY WITH TIA 607-C.
A
E-101D
E-101D
2DATA RM
112 (TYP.)
ETD (TYP.)
109109
H1C2 (E)
H1C2 3,5,7 H1C2
4,6,8 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
4/
0:
4:
A
M
REFERENCE PLAN - ENERGY CENTER (EC) -
LEVEL 1
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-101D
ACC
N
3/32" = 1'-0"
REFERENCE PLAN - ENERGY CENTER (EC) - LEVEL 11
N
1/4" = 1'-0"
ENERGY CENTER (EC) - DATA ROOM 104 - DEMO2
N
1/4" = 1'-0"
ENERGY CENTER (EC) - DATA ROOM 104 - NEW3
EC
ELECTRICAL KEYNOTES
108 PROVIDE NEW 208V, 30A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE POWER DISTRIBUTION UNIT (PDU). BASIS OF DESIGN ZONIT ZPDS-208V30A-L21-4L21-20R-CR. REFER TO DETAIL 2/E-502
FOR PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
109 PROVIDE NEW 208V, 30A, 3-PHASE L21-30R RECEPTACLE TO SERVE POWER TO RACK MOUNTED
UPS AND ZONE PDU. REFER TO DETAIL 2/E-502 FOR PDU ARRANGEMENT IN
TELECOMMUNICATION RACK.
112 REMOVE EXISTING RECEPTACLES ON COMMUNICATION RACKS. REMOVE ASSOCIATED
CONDUITS AND CIRCUITING BACK TO SOURCE PANEL.
119 PROVIDE SECURITY CAMERA - INDOOR HD PTZ DOME SURVEILLANCE CAMERA, 12X OPTICAL
ZOOM WITH AUTOFOCUS, 10X DIGITAL ZOOM, 1080P RESOLUTION AT 35/30 FRAMES PER
SECOND, H.264 STREAM. IP51 RATED AGAINST DUST AND DRIPPING WATER (SUITABLE FOR
SPRINKLER ACTIVATION CONDITIONS), POWER-OVER-ETHERNET (MAX 13 WATTS), 1/2.3" CMOS SENSOR, 3.8-42.99MM FOCAL LENGTH, F1.4-F2.1 VARIABLE MAXIMUM APERTURE, 360° PAN, 180° TILT. FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ALL NECESSARY POWER
SUPPLIES, SURGE PROTECTOR, MOUNTS AND WIRING FOR POWER, DATA, AND CONTROL FOR
A COMPLETE INSTALLATION. COORDINATE INSTALLATION LOCATION WITH VA.
122 PROVIDE BONDING TO THE NEAREST STEEL COLUMN. GROUNDING/ BONDING CONDUCTORS
SHALL COMPLY WITH TIA 607-C.
Z Y X W V U
T S R Q P O N M L K J H
G F E D C B A
7.3
M A
T C
H L
IN
E M
A T
C H
L
IN
E
AREA A
AREA B
A
-E -1
A
A
-E -1
B
A
-E -1
A
A
-E -1
B th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:4
A
M
REFERENCE PLAN - ACC - LEVEL 2
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-102
ACC
N
3/64" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 21
E-402A
E-402A
E-402A
Z Y X W V U
T S R Q P O N M L K
7.3
TELECOM
2A018
TELECOM
2A004
TELECOM
2A143
E-402A
E-402A
E-402A th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:4
A
M
REFERENCE PLAN - ACC - LEVEL 2 - AREA
A
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-102A
ACC
N
1/16" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 2 - AREA A1
E-402B
E-402B
E-402B
J H
G F E D C B A
7.3
TELECOM
2B310
TELECOM
2B102
TELECOM
2B003
E-402B
E-402B
E-402B th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:5
A
M
REFERENCE PLAN - ACC - LEVEL 2 - AREA
B
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-102B
ACC
N
1/16" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 2 - AREA B1
E-403A
E-403A
E-403A
T S R Q P O N M L K
7.3
TELECOM
3A004
TELECOM
3A015
TELECOM
3A063
E-403A
E-403A
E-403A th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:5
A
M
REFERENCE PLAN - ACC - LEVEL 3 - AREA
A
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-103A
ACC
N
1/16" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 3 - AREA A1
DN
E-404A
E-404A
T S R Q P O N M L K
7.3
SERVER / MAIN
TELECOM
4A201
TELECOM
4A041
E-404A
E-404A th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
/2
:3
:5
A
M
REFERENCE PLAN - ACC - LEVEL 4 - AREA
A
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-104A
ACC
N
1/16" = 1'-0"
REFERENCE PLAN - ACC - LEVEL 4 - AREA A1
J J
J J
7.3
TELECOM
1A014
C1N3 (E)
C1N1 (E)
C1N2 (E)
C1NA (E)
C1CA (E)
C1C1 (E)
C1SA (E)
C1DN3 (E)
C1S1 (E)
LCP (E)
T-C1C1 (E)
T-C1C1 (E)
ELECTRICAL
ROOM
1A015
ETD
ETD
ETD
C1E1 (E)
7.3
TELECOM
1A014
103104
ELECTRICAL
ROOM
1A015
T-C1C1 (E)
C1S1 (E) C1SA (E)
C1DN3 (E)
T-C1C1 (E)
LCP (E)
107107
TGB-1A014
C1E1 9,11,13
C1E1 10,12,14
C1N3 (E)
C1N2 (E)
C1N1 (E)
C1NA (E)
C1CA (E)
C1C1 (E)
C1E1 (E)
120 (TYP)
S
7.3
TELECOM
1A024
101 (TYP.)
A1N1 (E)
A1N2 (E)
A1N3 (E)
A1DN1 (E)
ELECTRICAL
ROOM
1A025
112112
ETD
ETD
A1E1 (E)
A1C1 (E)
S
7.3
TELECOM
1A024105
104(TYP.)
A1N1 (E)
A1N2 (E)
A1N3 (E)
A1DN1 (E)
ELECTRICAL
ROOM
1A025
106(TYP)
109109
TGB-1A024
A1E1 37,39,41
A1E1 38,40,42
A1C1 (E)
A1E1 (E)
O
TELECOM
1A106
LCP (E)
B1C1 (E)
B1DN1 (E)
B1N1 (E)
B1N3 (E)
B1N2 (E)
ELECTRICAL
ROOM
1A105
112112
ETD
ETD
ETD
B1CA (E) B1E1 (E)
B1NA (E)
120(TYP)
O
TELECOM
1A106
105(TYP.)
103104
LCP (E)
B1C1 (E)
B1N2 (E)
B1N1 (E)
B1DN1 (E)
(TYP)
ELECTRICAL
ROOM
1A105
111111
TGB-1A106
B1E1
10,12,14
B1E1 9,11,13
B1N3 (E)
B1CA (E) B1E1 (E)
B1NA (E)
V
TELECOM
1A457
101 (TYP.)
J1EA (E)
112112
ETD
ETD
V
TELECOM
1A457
105(TYP.)
106(TYP.)
111111
TGB-1A457
J1EA (E)
J1EA
J1EA
J1EA
J1EA
J1EA
38,40,42
J1EA
32,34,36 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
4/
0:
4:
A
M
ENLARGED PLANS - ACC - LEVEL 1 - AREA
A
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-401A
ACC
N
1/4" = 1'-0"
TELECOM ROOM 1A014 - DEMO1
N
1/4" = 1'-0"
TELECOM ROOM 1A014 - NEW2
N
1/4" = 1'-0"
TELECOM ROOM 1A024 - DEMO3
N
1/4" = 1'-0"
TELECOM ROOM 1A024 - NEW4
N
1/4" = 1'-0"
TELECOM ROOM 1A106 - DEMO5
N
1/4" = 1'-0"
TELECOM ROOM 1A106 - NEW6
N
1/4" = 1'-0"
TELECOM ROOM 1A457 - DEMO7
N
1/4" = 1'-0"
TELECOM ROOM 1A457 - NEW8
ELECTRICAL KEYNOTES
101 DEMOLISH EXISTING RACK MOUNTED UPS.
102 DEMOLISH ALL EXISTING BONDING CONDUCTORS CONNECTED TO GROUND BAR. MAINTAIN
GROUND BAR FOR USE IN NEW WORK.
103 PROVIDE GROUNDING BACKBONE CONDUCTOR AS SHOWN ON DETAIL 1, SHEET 00-E-501. ALL
GROUNDING CONDUCTOR SIZES AND BONDING SHALL COMPLY WITH TIA 607-C.
104 PROVIDE NEW NAME TAG AND LABEL FOR EXISTING GROUND BAR.
105 PROVIDE NEW 20A RACK-MOUNTED UPS. BASIS OF DESIGN EATON BLADEUPS ( ZC0517700110000).
UPS SHALL SUPPLY A MINIMUM OF 20 MINUTES RUN TIME OF ITS CAPACITY.
106 PROVIDE TWO (2) NEW VERTICAL RACK-MOUNTED 208Y/120V, 3-PHASE, 20A INPUT POWER
DISTRIBUTION UNITS (PDU) PER RACK. BASIS OF DESIGN CHATSWORTH ECONNECT PDU
[PART#:L2-1N0G3, (30)C13, (6) C19]. REFER TO SHEET E-502 FOR PDU CONNECTION TO RACK
MOUNTED UPS, ZONE PDU'S AND OR 208Y/120V L21-20R RECEPTACLE DETAILS.
107 PROVIDE NEW 208V, 20A, 3-PHASE L21-20R RECEPTACLE TO SERVE POWER TO RACK MOUNTED UPS AND VERTICAL MOUNTED PDU ON ONE SIDE OF RACK. REFER TO DETAIL 1/E-502 FOR PDU
ARRANGEMENT IN TELECOMMUNICATION RACK.
108 PROVIDE NEW 208V, 30A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE POWER DISTRIBUTION UNIT (PDU). BASIS OF DESIGN ZONIT ZPDS-208V30A-L21-4L21-20R-CR. REFER TO DETAIL 2/E-502
FOR PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
109 PROVIDE NEW 208V, 30A, 3-PHASE L21-30R RECEPTACLE TO SERVE POWER TO RACK MOUNTED UPS AND ZONE PDU. REFER TO DETAIL 2/E-502 FOR PDU ARRANGEMENT IN TELECOMMUNICATION
RACK.
110 PROVIDE NEW 208V, 60A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE POWER DISTRIBUTION UNIT (PDU). BASIS OF DESIGN ZONIT ZPDS-208V60A-HW-6L21-20R. REFER TO DETAIL 4/E-502 FOR
PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
111 PROVIDE J-BOX WITH POWER TO SERVE RACK MOUNTED ZONE PDU. REFER TO DETAIL 4/E-502
FOR PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
112 REMOVE EXISTING RECEPTACLES ON COMMUNICATION RACKS. REMOVE ASSOCIATED CONDUITS
AND CIRCUITING BACK TO SOURCE PANEL.
119 PROVIDE SECURITY CAMERA - INDOOR HD PTZ DOME SURVEILLANCE CAMERA, 12X OPTICAL ZOOM WITH AUTOFOCUS, 10X DIGITAL ZOOM, 1080P RESOLUTION AT 35/30 FRAMES PER SECOND, H.264 STREAM. IP51 RATED AGAINST DUST AND DRIPPING WATER (SUITABLE FOR SPRINKLER
ACTIVATION CONDITIONS), POWER-OVER-ETHERNET (MAX 13 WATTS), 1/2.3" CMOS SENSOR,
3.8-42.99MM FOCAL LENGTH, F1.4-F2.1 VARIABLE MAXIMUM APERTURE, 360° PAN, 180° TILT.
FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ALL NECESSARY POWER SUPPLIES,
SURGE PROTECTOR, MOUNTS AND WIRING FOR POWER, DATA, AND CONTROL FOR A COMPLETE
INSTALLATION. COORDINATE INSTALLATION LOCATION WITH VA.
120 EXISTING CONTROL EQUIPMENT ENCLOSURE TO REMAIN.
H
TELECOM
1B002
T-D1S1 (E)
T-D1C1 (E)
T-D1E1 (E)
112112ETD
ETD
ELECTRICAL
ROOM
1B031
D1N3 (E) D1N2 (E) D1N1 (E)
D1S1 (E)
D1SA (E)
J-BOX D1NA (E)
D1C1 (E)
D1F1 (E)
LCP (E)
D1CA (E)
D1E2 (E)
D1NA (E)
120 (TYP)
H
TELECOM
1B002
103104
D1CA (E)
D1F1 (E)
D1NA (E)
D1E2 (E)
D1N2 (E)
D1S1 (E)
D1N1 (E)
D1SA (E)
D1NA (E)
D1C1 (E)
T-D1S1 (E)
T-D1E1 (E)
T-D1C1 (E)
105(TYP)
(TYP)
109109
TGB-1B002
ELECTRICAL
ROOM
1B031 D1E2
37,39,41 D1E2
19,21,23
D1N3 (E)
LCP (E)
J-BOX
TELECOM
1B006
ELECTRICAL
ROOM
1B007
T-E1C1 (E)
ETD
ETD
112(TYP)
E1CA (E)
E1S1 (E)
E1C1 (E)
E1NA (E)
E1N3 (E)
E1N1 (E)
E1N2 E1E1 (E)
120 (TYP)
TELECOM
1B006
105(TYP.)
103104
ELECTRICAL
ROOM
1B007
E1S1 (E)
E1N1 (E)
E1NA (E)
E1N2
E1N3 (E)
E1C1 (E)
T-E1C1 (E)
(TYP)
109109
TGB-1B006
E1E1 (E)
E1E1 31,33,35
E1E1 32,34,36
E1CA (E)
C
DATA
1B609
F1E2 (E)
ETD
ETD
ETD
112112112
DATA
1B609
C
(TYP.)103
F1E2 (E)
106(TYP)
109109
TGB-1B609
F1E2
F1E2
F1E2 19,21,23
F1E2 22,24,26
F1E2 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. EXP. 06/23/2021
ENGR REG. NO. EXP. 06/30/2021
TELECOM
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE
PRESCOTT, AZ 86301
(928) 774-0992
ELEC ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(405) 842-6100
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RSH
1225 N. LOOP WEST, SUITE 800
HOUSTON, TX 77008
(713) 864-2900
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
OH 20314270,
OH 06253,
Drawing Number
Building Number
CIVIL ENGINEER
OLSSON
550 ST. LOUIS ST.
SPRINGFIELD, MO 65806
(417) 885-1736
PHYSICAL SECURITY
FORCE PROTECT
10901 FRONT BEACH ROAD, SUITE 1415,
PANAMA CITY BEACH, FL 32407
(502) 836-4232
/2
4/
0:
5:
A
M
ENLARGED PLANS - ACC - LEVEL 1 - AREA
B
ABMES
FINAL BID DOCUMENTS
EHRM INFRASTRUCTURE UPGRADES –
COLUMBUS, OH – TIER 1
06/28/2021
757-21-701
CHALMERS P. WYLIE VA AMBULATORY CARE CENTER
420 NORTH JAMES ROAD
COLUMBUS, OH 43219
E-401B
ACC
N
1/4" = 1'-0"
TELECOM ROOM 1B002 - DEMO1
N
1/4" = 1'-0"
TELECOM ROOM 1B002 - NEW2
N
1/4" = 1'-0"
TELECOM ROOM 1B006 - DEMO3
N
1/4" = 1'-0"
TELECOM ROOM 1B006 - NEW4
N
1/4" = 1'-0"
DATA ROOM 1B609 - DEMO5
N
1/4" = 1'-0"
DATA ROOM 1B609 - NEW6
ELECTRICAL KEYNOTES
102 DEMOLISH ALL EXISTING BONDING CONDUCTORS CONNECTED TO GROUND BAR. MAINTAIN
GROUND BAR FOR USE IN NEW WORK.
103 PROVIDE GROUNDING BACKBONE CONDUCTOR AS SHOWN ON DETAIL 1, SHEET 00-E-501. ALL
GROUNDING CONDUCTOR SIZES AND BONDING SHALL COMPLY WITH TIA 607-C.
104 PROVIDE NEW NAME TAG AND LABEL FOR EXISTING GROUND BAR.
105 PROVIDE NEW 20A RACK-MOUNTED UPS. BASIS OF DESIGN EATON BLADEUPS (
ZC0517700110000). UPS SHALL SUPPLY A MINIMUM OF 20 MINUTES RUN TIME OF ITS CAPACITY.
106 PROVIDE TWO (2) NEW VERTICAL RACK-MOUNTED 208Y/120V, 3-PHASE, 20A INPUT POWER
DISTRIBUTION UNITS (PDU) PER RACK. BASIS OF DESIGN CHATSWORTH ECONNECT PDU
[PART#:L2-1N0G3, (30)C13, (6) C19]. REFER TO SHEET E-502 FOR PDU CONNECTION TO RACK
MOUNTED UPS, ZONE PDU'S AND OR 208Y/120V L21-20R RECEPTACLE DETAILS.
108 PROVIDE NEW 208V, 30A, 3-PHASE HORIZONTAL RACK-MOUNTED ZONE POWER DISTRIBUTION UNIT (PDU). BASIS OF DESIGN ZONIT ZPDS-208V30A-L21-4L21-20R-CR. REFER TO DETAIL 2/E-502
FOR PDU ARRANGEMENT IN TELECOMMUNICATION RACK.
109 PROVIDE NEW 208V, 30A, 3-PHASE L21-30R RECEPTACLE TO SERVE POWER TO RACK MOUNTED
UPS AND ZONE PDU. REFER TO DETAIL 2/E-502 FOR PDU ARRANGEMENT IN
TELECOMMUNICATION RACK.
112 REMOVE EXISTING RECEPTACLES ON COMMUNICATION RACKS. REMOVE ASSOCIATED
CONDUITS AND CIRCUITING BACK TO SOURCE PANEL.
119 PROVIDE SECURITY CAMERA - INDOOR HD PTZ DOME SURVEILLANCE CAMERA, 12X OPTICAL
ZOOM WITH AUTOFOCUS, 10X DIGITAL ZOOM, 1080P RESOLUTION AT 35/30 FRAMES PER
SECOND, H.264 STREAM. IP51 RATED AGAINST DUST AND DRIPPING WATER (SUITABLE FOR
SPRINKLER ACTIVATION CONDITIONS), POWER-OVER-ETHERNET (MAX 13 WATTS), 1/2.3" CMOS SENSOR, 3.8-42.99MM FOCAL LENGTH, F1.4-F2.1 VARIABLE MAXIMUM APERTURE, 360° PAN, 180° TILT. FURNISHED AND INSTALLED BY CONTRACTOR. PROVIDE ALL NECESSARY POWER
SUPPLIES, SURGE PROTECTOR, MOUNTS AND WIRING FOR POWER, DATA, AND CONTROL FOR
A COMPLETE INSTALLATION. COORDINATE INSTALLATION LOCATION WITH VA.
120 EXISTING CONTROL EQUIPMENT ENCLOSURE TO REMAIN.
S
7.3
TELECOM
2A004
A2N1 (E)
A2N2 (E)
A2N3 (E)
ELECTRICAL
ROOM
2A005
ETD
ETD
112112
A2E1 (E)
A2C1 (E)
J-BOX
(TYP)
S
7.3
TELECOM
2A004
A2N1 (E)
A2N2 (E)
(TYP)
(TYP)
ELECTRICAL
ROOM
2A005
109109
TGB-2A004
A2E1 29,31,33
A2E1 28,30,32
A2E1 (E)
A2N3 (E)
A2C1 (E)
J-BOX
7.3
TELECOM
2A018
ELECTRICAL
ROOM
2A017
C2NA (E)
C2CA (E)
C2C1 (E)
LCP (E)
ETDETD
112112
C2E1 (E)
120 (TYP)
7.3
TELECOM
2A018
105(TYP.)
1…