Attachment 11 DMC Fire Water Lines Maps.pdf

PDF 5 MB Posted

Attached to
MAINTENANCE AND REPAIR SERVICE POTABLE AND FIRE WATER GRID AT DARBY MILITARY COMMUNITY (DMC)
Solicitation number
W912PF25QA087
Issued by

About this file

This document is a site plan drawing for a Naval Facilities Engineering Command (NAVFAC) infrastructure improvement project at Camp Darby in Livorno, Italy. The contract number is N62470-17-R-5002 and the project is titled "Improve Weapons Storage Facility" for the Department of the Navy. The detailed site plan shows multiple specialized facility areas including:

  1. Specific infrastructure zones with precise mapping:
  • Munition Dock (Banchina Munizioni)
  • Loading/Unloading Dock
  • Inspection Dock
  • Areas 10-11
  • Mancino Road

The drawing is prepared by SGAI s.r.l. (an Italian engineering firm) and CIMOLAI, scaled at 1:2500, and includes detailed fire water network planning across the facility. The plan demonstrates complex site infrastructure layout with multiple reference zones, road networks, and specialized facility zones, indicating a comprehensive military facility improvement project.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

-1

.8

-1

.8

-1

.8

M H

#0 7

V

IO

N E

S

A N T O

N

IO

V

IO

N E D

EL C

ASO

N E

105 ALLEY ROAD

BASSETTO ROAD

LANCE LANE ROAD

HAWK ALLEY ROAD

BULLET BLUD ROAD

BOMB BLUD ROAD

UNIMPROVED ROAD

CANNON ROAD

VAN

NIN

I RO

A

D

RIVER

E O

S N

INSPECTION DOCK / BANCHINA ISPEZIONE

REFERENCES / RIFERIMENTI:

AFI60 ÷ AFI61

LOADING UNLOADING DOCK /

BANCHINA CARICO SCARICO

REFERENCES / RIFERIMENTI:

AFL50 ÷ AFL53

AREAS 10-11 / AREE 10-11

REFERENCES / RIFERIMENTI:

MFP10 ÷ MFP11

MUNITION DOCK / BANCHINA MUNIZIONI

REFERENCES / RIFERIMENTI:

MFM50 ÷ MFM54

MANCINO ROAD / VIA MANCINO

REFERENCES / RIFERIMENTI:

MFM50 ÷ MFM54

MFS20 ÷ MFS21

MFS30 ÷ MFS31

Corso Lino Zanussi, 26 - 33080 Porcia (PN) - Italy Tel. +39 0434 5581 - Fax +39 0434 361401 www.cimolai.com - info@cimolai.com

CIMOLAI

CIMOLAI DRAWING NO.

CONSTR. CONTR. NO.

EPROJECT NO.:

SCALE:

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

D E

P A

R T

M E

N T

O F

T H

E N

A V

Y

L A

N T

C A

P

IT

A L I M

P R

O V

E M

E N

T S

N O

R F

O L K

V

IR

G

IN

IA

D E

S C

R

IP

T

IO

N S

Y M

A

P P

R D

A T

E

L

IV

O R

N O

IT

A L

Y C

A M

P D

A R

B Y

N62470-17-R-5002

1382694

E R

I:

I M

P R

O V

E W

E A

P O

N S

S T

O R

A G

E F

A C

IL

IT

Y

N A

V A

L F

A C

IL

IT

IE

S

E N

G

IN

E E

R

IN

G C

O M

M A

N D

A T

L A

N T

IC

APPROVED BY:

CHECKED BY:

DESIGNED BY:

Via Mariotti, 20 - 47833 Morciano di Romagna (RN)

ITALY

P.IVA 01894420403

tel/fax +39 0541988277 - e -mail: sgai@sgai.com pec: sgai@pec.sgai.net www.sgai.com

SGAI s.r.l. di E.Forlani & C.

Studio di Ingegneria e Geologia Applicata

SISTEMA GESTIONE QUALITA' ISO 9001:2015 RINA 4387/00/S

REF. DRAWING PE:

1 : 2500

WSF-MRD-13-DPD-00ZZ-MFP00-A-01

M A

N C

IN

O

R O

A D

S

IT

E

F

IR

E W

A

TE

R P

LA

N

K

E Y

P

LA

N

V

IA

M A

N C

IN

O

P

L A

N

IM

E T

R

IA

D E

L L

A R

E T

E A

N T

IN

C

E N

D

IO

P

IA

N

T A

C H

IA

V

E

S. Lotti

M. Cerri

F. Forlani

E

.M

/1

1/

F.

F O

R

LA

N I

U

P D

A

TE

R E

FE

R

E N

C E

S A

N D

A D

D N

O

TE

S

/1 1/

F.

F

O R

LA

N

I

SCALE: 1 : 2500

SCALA: 1 : 2500

VIA MANCINO - PIANTA CHIAVE SEZIONI

MANCINO ROAD - SECTIONS KEY-PLAN

CHANGE REFERENCE

giuliana.rogano Casella di testo giuliana.rogano Callout Test Location pressure test tool

PIANTA GENERALE ACQUA INDUSTRIALE con DOCK
PIANTA GENERALE ACQUA INDUSTRIALE con riquadri stampa REV01
2017 034 WSF Fire System Test Report - 5apr2022 5
6-AS BUILT 30
6-AS BUILT 31
6-AS BUILT 32
6-AS BUILT 33
6-AS BUILT 34
6-AS BUILT 35
6-AS BUILT 36

File details come from the government source that posted it. Updated .