Attachment 11 CLIN G Drawings.pdf
PDF 4 MB Posted
- Solicitation number
- 12805B24R0036
About this file
This document contains drawings and specifications for CLIN "G" - Security Landscaping as part of the Site Security Improvements project for the National Bio & Agro Defense Facility (NBAF) in Manhattan, Kansas. The drawings provide details for landscape hardening, new concrete pedestrian sidewalks, and routing new electrical work around the new landscaping. The project is being procured by the United States Department of Agriculture (USDA) Agricultural Research Service (ARS) Plains Area Acquisition Office as a $1-5 million Firm Fixed Price construction contract, anticipated to be set aside for Small Businesses with a NAICS code of 236220 Commercial and Institutional Building Construction. A mandatory site visit will be required as part of the evaluation factors. The Request for Proposal is expected to be issued around July 2, 2024 and will be accessible via sam.gov.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
USDA
VICINITY MAP (1" = 0.4 MILES)
NATIONAL BIO AND AGRO DEFENSE FACILITY (NBAF)
1980 DENISON AVENUE
MANHATTAN, KS 66502
INDEX OF DRAWINGS
CLIN "G" - SECURITY LANDSCAPING
TITLE SHEET
T-101
GENERAL NOTES:
1. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO PERFORMING
WORK OR FABRICATION OR PURCHASE OF EQUIPMENT, MATERIALS, AND ASSEMBLIES. ANY DEVIATIONS SHALL BE BROUGHT TO THE CONTRACTING OFFICER'S ATTENTION FOR RESOLUTION BEFORE PROCEEDING WITH ANY
CONSTRUCTION, FABRICATION, OR EQUIPMENT PURCHASE.
2. THE FACILITY WILL REMAIN IN OPERATION DURING ALL PHASES OF CONSTRUCTION. ALL MEANS OF EGRESS
MUST REMAIN FREE AND CLEAR.
3. COORDINATE CONSTRUCTION ACCESS AND STAGING AREA(S) WITH CONTRACTING OFFICER PRIOR TO
COMMENCING WORK.
U.S. DEPARTMENT OF AGRICULTURE
AGRICULTURAL RESEARCH SERVICE
SITE SECURITY IMPROVEMENTS DESIGN
CONTRACT NO: 12805B23D0001
NATIONAL BIO AND AGRO DEFENSE FACILITY (NBAF)
MANHATTAN, KANSAS
SHEET NO. DRAWING NO. TITLE
T-101 1 OF 6 CLIN "G" - SECURITY LANDSCAPING TITLE SHEET
T-102 2 OF 6 CLIN "G" - GENERAL NOTES
V-101 3 OF 6 SURVEY PLAN - CLIN "G"
C-101 4 OF 6 DEMO PLAN - CLIN "G"
C-201 5 OF 6 SITE PLAN - CLIN "G"
C-501 6 OF 6 CLIN "G" - DETAILS
U
D A
S
PROJECT LOCATION
PROJECT
LOCATION
PROJECT LOCATION
LOCATION MAP (1" = 60 MILES)
lhenderson Chip NBAF 8
CLIN "G" - GENERAL NOTES
T-102
U
D
DEMOLITION NOTES
D-1 PROTECT ASSETS AND FINISHES NOT SHOWN TO BE REMOVED. ANY DAMAGE CAUSED BY
CONSTRUCTION OPERATIONS SHALL BE REPAIRED TO MATCH THE EXISTING CONDITIONS AT NO
COST TO THE GOVERNMENT.
D-2 AT A MINIMUM, PROVIDE 4' TALL TEMPORARY ORANGE HIGH DENSITY POLYETHYLENE SAFETY
FENCE TO ISOLATE HAZARD AND CONSTRUCTION FROM UNAUTHORIZED ACCESS.
D-3 CARE SHALL BE TAKEN IN ALL OPEN SUBGRADES TO PREVENT DETERIORATION CAUSED BY
WEATHER. DEWATER ALL OPEN SUBGRADES AS REQUIRED TO MAINTAIN STABILITY.
D-4 AT A MINIMUM, PROVIDE TEMPORARY TRAFFIC CONTROL AS REQUIRED FOR PHASING AND
CONSTRUCTION. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE MANUAL OF
UNIFORM TRAFFIC CONTROL DEVICES (MUTCD).
D-5 THE CONTRACTOR SHALL CONTROL THE SPREAD OF DUST AND IRRITANTS TO OTHER SPACES, ADJACENT BUILDINGS AND OUTSIDE OF DESIGNATED WORK AREAS.
D-6 THE CONTRACTOR SHALL PROVIDE CLEAN, STRAIGHT, NEAT CUTS FOR DEMOLITION THAT MINIMIZE
IMPACTS AND ADVERSE EFFECTS ON EXISTING FINISHES. COORDINATE THE LOCATION OF THE
CUTS TO ACCOMMODATE FINAL FINISHES.
D-7 WHERE NEW WORK IMPACTS RIGID PAVEMENT, CURB, OR CONCRETE WALKS, THE CONCRETE
SHALL BE SAW-CUT AND REMOVED AND REPLACED TO THE NEAREST CONTROL OR EXPANSION
JOINT, BE REPLACED LIKE-IN-KIND AND HAVE THE JOINT SEALED.
GENERAL NOTES
GN-1 THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE THE PROJECT SPECIFICATIONS.
REVIEW ALL PROJECT DOCUMENTS PRIOR TO START OF CONSTRUCTION. REPORT ANY
DISCREPANCIES TO CONTRACTING OFFICER PRIOR TO PROCEEDING WITH WORK. DIMENSIONS
RELATING TO EXISTING CONSTRUCTION ARE TO BE FIELD VERIFIED. THE CONTRACTOR SHALL
IMMEDIATELY COMMUNICATE, IN WRITING TO THE CONTRACTING OFFICER, CONCERNS WHERE
THEY BELIEVE DESIGN DOCUMENTS ARE INSUFFICIENT, INADEQUATE OR INCORRECT FOR
PERFORMING THE CONSTRUCTION WORK.
GN-2 EXISTING UTILITIES ARE SHOWN IN THEIR APPROXIMATE LOCATIONS AS LOCATED AT THE TIME
OF THE DESIGN SITE VISIT.
AT THE BEGINNING OF THE PROJECT AND PRIOR TO ORDERING MATERIALS:
· THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE EXACT LOCATION
OF EXISTING UTILITIES ON SITE.
· WHERE NEW WORK IS INDICATED TO CROSS EXISTING UTILITIES, THE CONTRACTOR
SHALL ANTICIPATE RELOCATING THE EXISTING SERVICE TO ACCOMMODATE THE NEW
INSTALLATION.
· THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL UTILITIES AND DETERMINE THE
POINTS OF CONNECTIONS (SUCH AS WATER, SEWER, ELECTRIC, GAS, COMMUNICATION
AND STORM DRAINAGE).
· THE CONTRACTOR SHALL PERFORM A FULL LOCATION ALONG THE LENGTH OF ANY
GRAVITY UTILITY ALIGNMENT TO DETERMINE IF THERE ARE OBSTRUCTIONS THAT
PREVENT THE CONSTRUCTION OF THE PLANNED DESIGN.
DOCUMENT ALL FINDINGS AND PROVIDE TO THE CONTRACTING OFFICER PRIOR TO BEGINNING
CONSTRUCTION.
GN-3 COORDINATE CIVIL WORKS AND OTHER TRADES.
GN-4 ALL DETAILS AND SECTIONS ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE
CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT EXCEPT
WHERE A SEPARATE DETAIL IS SHOWN.
GN-5 THE CONTRACTOR SHALL TAKE CARE, BY THE USE OF GRADING, DIVERSION AND DEWATERING, TO PREVENT PONDING OF WATER ON SITE IN AREAS OF OPEN TRENCHES AND
STRUCTURAL/PAVEMENT SUBGRADES.
GN-6 THE CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS OF ALL OF THE NEW UTILITIES AND
SERVICE, SITE FEATURES AND CHANGES MADE DURING THE WORK.
GN-7 PRODUCTS SHALL BE INSTALLED PER MORE STRINGENT REQUIREMENTS OF THE DESIGN
DOCUMENTS OR THE MANUFACTURER'S PRINTED INSTRUCTIONS FOR THE INDICATED
APPLICATION. THESE INSTRUCTIONS SHALL BE MAINTAINED ON SITE FOR THE DURATION OF THE
INSTALLATION AT A MINIMUM.
GN-8 AT THE COMPLETION OF GRADING, THE CONTRACTOR SHALL RESPREAD 4" OF TOP SOIL ON ALL
DISTURBED UNIMPROVED LAWN AREAS, AS REQUIRED TO ESTABLISH VEGETATIVE COVER. AT
THE COMPLETION OF THE PROJECT, HAUL EXCESS SOIL OFF SITE.
GN-9 TEMPORARY SEED OR STABILIZE ALL AREAS OF EXPOSED EARTH THAT ARE PLANNED TO BE
UNFINISHED OR UNWORKED FOR A PERIOD EXCEEDING 14 DAYS.
GN-10 ALL DE-WATERING AND WASH-WATER SHALL BE PRE-TREATED WITH AN ACCEPTED MANAGEMENT
PRACTICE PRIOR TO BEING DISCHARGED INTO A STORMWATER CONVEYANCE.
PHASING NOTES
PH-1 THE CONTRACTOR SHALL PROVIDE A SCHEDULE OF CONSTRUCTION TO THE CONTRACTING
OFFICER PRIOR TO BEGINNING CONSTRUCTION. DETAILS SHALL BE PROVIDED NOTING WHERE
CONSTRUCTION WILL OCCUR, SEQUENTIAL PHASING AND THE DURATION OF THE WORK TO BE
PERFORMED. THE SCHEDULE SHALL ALSO DETAIL THE LENGTHS OF ANTICIPATED
INTERRUPTIONS AND HOW THE CONTRACTOR WILL MINIMIZE INTERRUPTIONS TO THE
GOVERNMENT'S NORMAL OPERATIONS.
RECORD DRAWING NOTES:
RD-1 CONTRACTOR SHALL MAINTAIN UPDATED RECORD DRAWINGS AT ALL TIMES THROUGH THE
DURATION OF THE PROJECT.
RD-2 DURING CONSTRUCTION OF THE PROJECT, CONTRACTOR SHALL BE RESPONSIBLE FOR
DOCUMENTING ANY CONTRACTING OFFICER APPROVED FIELD CONSTRUCTION REVISIONS TO
THE DESIGN DEPICTED ON APPROVED CONSTRUCTION DRAWINGS. THESE REVISIONS SHALL BE
USED TO PREPARE RECORD AS-BUILT DRAWINGS OF COMPLETED CONSTRUCTION.
RD-3 ALL VARIATIONS IN PROJECT CONDITIONS, LOCATIONS, AND CONFIGURATIONS, AND ANY
OTHER CHANGES OR DEVIATIONS FROM THE INFORMATION PRESENTED ON THE ORIGINAL,
APPROVED CONSTRUCTION DRAWINGS SHALL BE NOTED. THIS INCLUDES BURIED OR
CONCEALED CONSTRUCTION AND UTILITY FEATURES THAT WERE REVEALED DURING
CONSTRUCTION.
STOP
STOP HERE
ON RED
STAY RIGHT
OF ISLAND
BICYCLE
PARKING
STOP HERE
ON RED
4'X6' AREA INLET
CONCRETE
RIM=1113.37
IN(NW) 30"RCP=1087.87
OUT(SE) 30"RCP=1087.67
4'X4' AREA INLET
CONCRETE
RIM=11052.77
OUT(N) 15"RCP=1097.07
4'X4' AREA INLET
CONCRETE
RIM=1102.23
IN(S) 15"RCP=1095.78
OUT(E) 15"RCP=1095.76
AREA INLET
10" DIA PLASTIC
RIM=1100.12
OUT(W) 6"CPP=1097.80
UTILITY VAULT
UTILITY VAULT
WROUGHT IRON FENCE
WITH STAGGERED CAPPED BLOCK (TYP)
WEDGE BARRIER
WEDGE BARRIER
UTILITY VAULT
ELECTRIC TANSFORMER
6" CPP
LIMESTONE BARRIER
SNSC B AND CL
RULES AND REGULATIONS WEDGE BARRIER
CONTROL BOX
AREA INLET
UTILITY VAULT
SIGNAL VAULT
LANDSCAPING
LANDSCAPING
LANDSCAPING
CONCRETE
30" RCP
30" RCP
" R
CP
1/2" X 24" REBAR
W/PINK CP CAP
ELEV=1109.935
N=319599 E=1713763.40
1/2" X 24" REBAR
W/PINK CP CAP
ELEV=1098.170
N=319599.16 E=1713422.42
BM #62
STAINLESS STEEL
SECURITY GATE
COVERED
BUS STOP
1' STOP BAR
CANOPY
CANOPYSOLID WHITE LINE SOLID WHITE LINE
DASHED WHITE LINESOLID WHITE LINESOLID WHITE LINE
SECURITY
TURNSTILE
GATE ARM
GATE ARM
GATE ARM
15" RCP
30" RCP
FF=1100.73
BUILDING 6
B2 AND C3
SIGNAL
SIGNAL
GATE ARM
1' STOP BAR
U
D
SURVEY PLAN - CLIN "G"1
SCALE: 1" = 20'V-101
SCALE: 1" =
020 2010
20'
SURVEY PLAN - CLIN "G"
V-101
BENCHMARKS:
BM #61 CHISELED SQUARE ON CURBLINE, NORTH SIDE OF CENTER PARKING ISLAND, WEST SIDE CURBLINE.
N=320097.15 E=1713512.47
BM #62 CHISELED SQUARE ON CURBLINE, 27.5' EAST OF LOT CORNER DIRECTLY NORTH OF DENISON GATE N=319718.12 E=1713526.18
BM #63 CHISELED SQUARE JUST WEST OF INLET ON NORTH SIDE OF GAURD HOUSE AT DISCOVERY WAY N=320309.33 E=1714477.18
THIS SURVEY DOES NOT ADDRESS THE EXISTENCE OR NONEXISTENCE OF WETLANDS, ENVIRONMENTAL HAZARDS, CEMETERIES OR ANY UNDERGROUND STRUCTURE NOT OBSERVED DURING THE COURSE OF
THE SURVEY.
LEGEND
MONUMENT FOUND
PLATTED PER KANSAS STATE UNIVERSITY
ADDITION FINAL PLAT
MEASURED
CALCULATED
STREET SIGN
STEEL BOLLARD
CANOPY SUPPORT
LIGHT POLE
SPEAKER BOX
SPOT/FLOOD LIGHT
AIR CONDITIONING UNIT
ELECTRIC MANHOLE
UTILITY MANHOLE
GAS LINE RISER VALVE
UNDERGROUND GAS LINE
GAS PUMP
WATER LINE GATE VALVE
WATER SPIGOT
MONITOR WELL
SPRINKLER CONTROL BOX
FIRE HYDRANT
SANITARY SEWER MANHOLE
SANITARY SEWER CLEAN-OUT
SANITARY SEWER LINE
STORM SEWER MANHOLE
TELEPHONE MANHOLE
UNDERGROUND FIBER OPTIC CABLE
TRAFFIC CONTROL POLE
HANDICAP SIGN
HANDICAP PAINTED SYMBOL
GATE POST
WROUGHT IRON FENCE
WIRE FENCE
DECIDUOUS TREE W/ SIZE & DRIP LINE
EVERGREEN TREE W/ SIZE & DRIP LINE
1' CONTOUR INTERVAL
SPOT ELEVATION AT GROUND/PAVEMENT
CONCRETE
GRAVEL
POST INDICATOR VALVE
AREA INLET
VERTICAL DATUM IS NAVD88 DERIVED FROM CONNECTIONS TO NATIONAL CORS NETWORK VIA GPS STATIC SESSIONS ON PROJECT CONTROL PROCESSED WITH THE NATIONAL GEODETIC SURVEY'S OPUS PROJECTS UTILITY. ORTHOMETRIC HEIGHT WAS CALCULATED USING THE GEOID18 MODEL. UNITS ARE
U.S. SURVEY FEET.
HORIZONTAL DATUM IS THE KANSAS STATE PLANE COORDINATE SYSTEM, NORTH ZONE 1501, NAD83(2011) EPOCH 2010.0 AS DERIVED FROM CONNECTIONS TO NATIONAL CORS NETWORK VIA GPS STATIC SESSIONS ON PROJECT CONTROL PROCESSED WITH THE NATIONAL GEODETIC SURVEY'S OPUS PROJECTS UTILITY.
PROJECT COORDINATES WERE SCALED TO THE GROUND USING A COMBINED SCALE FACTOR OF
0.99990851687 AND APPLIED AT A GRID COORDINATE VALUE OF 320220.8087 NORTH AND 1713558.2166 EAST.
UNITS ARE U.S. SURVEY FEET. GROUND TO GRID CONVERSION: GRID NORTHING = ((PROJECT "GROUND" NORTHING - 320220.8087) * 0.99990851687) + 320220.8087 GRID EASTING = ((PROJECT "GROUND" EASTING - 1713558.2116) * 0.99990851687) + 1713558.2166.
SURVEY NOTES:
ALL SURVEY WORK WAS PERFORMED BY KAW VALLEY ENGINEERING, JULY 2023.
UTILITY LOCATE DATA, AS PERFORMED BY BLOODHOUND (JULY 2023) IS
OVERLAID ON THE PROPOSED CIVIL DRAWING.
Catch Basin Rim Elevation 1113.90
Catch Basin Rim Elevation 1102.70
Catch Basin Rim Elevation 1102.80
Catch Basin Rim Elevation 1114.00
UEx UEx UEx UEx
U E x U
E x
U Ex
UEx UEx UEx UEx UEx
UEx
UEx UEx UEx UEx UEx
U Ex
U Ex
U Ex
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx UEx
UEx
UEx UEx
SDx
SDx
SDx
SDx SDx
SDx SDxSDx
SDx
SDx
SDx
SDx SDx
SDx SDxSDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
UEx UEx
UEx
UEx
UEx UEx UEx UEx UEx
U E x U
E x
U E x U
E x
UEx UEx UEx UEx
UEx UEx UEx UEx
UExUEx
UEx
UEx UEx UEx UEx
UEx UEx
UEx UEx UEx UEx UEx UEx UEx UEx UEx
UEx UEx UEx
UEx UEx UEx UEx
UEx UEx UEx UEx UEx
UEx UEx UEx
UEx
UEx
UEx
UEx
SDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDx
SDx SDx
SDx SDx
SDx
SDx
SDx
SDx
SDx
SDx
SDx SDx
SDx SDx
SDx
SDx
SDx
SDx
SDx
SDx
SDx SDx SDx SDx SDxSDx SDx SDx SDx SDx
SDxSDxSDxSDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDxSDxSDxSDx
SDxSDxSDxSDxSDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDxSDxSDxSDxSDx
W x W x W x
W x W x W x W x W x W x W x W x W x W x
U
D
DEMO PLAN - CLIN "G"1
SCALE: 1" = 20'C-101
SCALE: 1" =
020 2010
20'
DEMO PLAN - CLIN "G"
C-101
1. REMOVE AND DISPOSE OF TREES AND ROOTS TO A MINIMUM 24"
BELOW GRADE.
2. SAWCUT, REMOVE AND DISPOSE OF CONCRETE SIDEWALK.
KEYED NOTES :#
TREE DEMOLITION
LEGEND - DEMOLITION
CONCRETE PAVEMENT/
Catch Basin Rim Elevation 1113.90
Catch Basin Rim Elevation 1102.70
Catch Basin Rim Elevation 1102.80
Catch Basin Rim Elevation 1114.00
UEx UEx UEx UEx
U E x U
E x
U Ex
UEx UEx UEx UEx UEx
UEx
UEx UEx UEx UEx UEx
U Ex
U Ex
U Ex
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx UEx
UEx
UEx UEx
SDx
SDx
SDx
SDx SDx
SDx SDxSDx
SDx
SDx
SDx
SDx SDx
SDx SDxSDx
SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx SDx
UEx UEx
UEx
UEx
UEx UEx UEx UEx UEx
U E x U
E x
U E x U
E x
UEx UEx UEx UEx
UEx UEx UEx UEx
UExUEx
UEx
UEx UEx UEx UEx
UEx UEx
UEx UEx UEx UEx UEx UEx UEx UEx UEx
UEx UEx UEx
UEx UEx UEx UEx
UEx UEx UEx UEx UEx
UEx UEx UEx
UEx
UEx
UEx
UEx
SDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDx
SDx SDx
SDx SDx
SDx
SDx
SDx
SDx
SDx
SDx
SDx SDx
SDx SDx
SDx
SDx
SDx
SDx
SDx
SDx
SDx SDx SDx SDx SDxSDx SDx SDx SDx SDx
SDxSDxSDxSDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDxSDxSDxSDx
SDxSDxSDxSDxSDxSDxSDxSDxSDxSDx SDxSDxSDxSDxSDxSDxSDxSDxSDxSDx
W x W x W x
W x W x W x W x W x W x W x W x W x W x
UEx
UEx
UEx UEx
UEx UEx
UEx UEx
UEx UEx
UEx
UEx UEx
UEx UEx
UEx UEx
UEx
UEx
UEx
UEx
UEx
UEx
UEx
UEx
SDx SDx
SDx SDx
U
D
SITE PLAN - CLIN "G"1
SCALE: 1" = 20'C-201
SCALE: 1" =
020 2010
20'
SITE PLAN - CLIN "G"
C-201
1. PROVIDE LANDSCAPE HARDENING. (SEE DETAIL 1/C-501).
2. PROVIDE NEW CONCRETE PEDESTRIAN SIDEWALK. (SEE DETAIL
2/C-501).
3. PROVIDE HANDHOLE AND NEW ELECTRICAL TO ROUTE AROUND
NEW WORK MATCH CONDUCTORS "LIKE-IN-KIND".
KEYED NOTES :#
END
BEG
NEW CONCRETE PAVEMENT
LEGEND
NEW LANDSCAPE HARDENING
C-201
ENLARGED SITE PLAN - CLIN "A"2
SCALE: NONEC-201
4' TYPICAL
4' MAX.
NARROW SIDEWALK TO 4' IN
WIDTH BETWEEN THE NEW
LANDSCAPE HARDENING
END
BEG
LANDSCAPE HARDENING DETAIL1
SCALE: 1/2" = 1'-0"C-501
"RUSTIC" STONE BOLDER
ELEVATION VIEW
PLAN/LAYOUT VIEW
6"
4" 4"
2"
NOTE:
1. PROVIDE MACRO-FIBER REINFORCING @ 1 LB/CY MIN., IN
LIEU OF WWF, IN AREAS OF STANDARD PEDESTRIAN CONC.
2. PROVIDE #3 REBAR IN THICKENED CONC. EDGES @ TRENCH
AND AREAS DRAINS.
SEALANT NOTE:
CONCRETE "THYME" COLORED - SEALANT PECORA 890 'BEIGE;
CONCRETE "CHARCOAL" COLORED - SEALANT PECORA 890 'ALUMINUM STONE'
FINISH GRADE - SEE PLAN
AGGREGATE BASE
COMPACTED SUBGRADE
6"x6"-W1.4xW1.4 WWF, @ COLORED CONC. ONLY
4" CONCRETE PAVEMENT
LIGHT DUTY PEDESTRIAN CONCRETE SIDEWALK2
SCALE: NONEC-501
U
D
CLIN "G" - DETAILS
C-501
02' 2'
1'-0"SCALE: 1/2" =
2'-6" ± 2"
4'-0" ± 6"
FINISHED GRADE
5'-0" EMBED
BACKFILL IN 8" LOOSE
LIFTS AND COMPACT
TO A MINIMUM 95%
ASTM D698
4' MAXIMUM PERMISSIBLE
SPACING AT THE WIDEST
EXPOSED LOCATION
THICKNESS
2'-0" MINIMUM
WIDTH
4'-0" ± 6"
BOULDER APPEARANCE:
1. STONE BOULDERS SHALL BE QUARRIED
FROM AND AREA THAT PROVIDES A SIMILAR
APPEARANCE TO THE CAMPUS' EXISTING
STONE FINISHES. A MINIMUM OF THREE
REASONABLY COMPLYING SAMPLES OF THE
PROPOSED MATERIAL SHALL BE PROVIDED
TO THE USDA'S CONTRACTING OFFICER
FOR EVALUATION AND WRITTEN APPROVAL
PRIOR TO BEING INCORPORATED INTO THE
PROJECT.
2. ALL EXPOSED SURFACES SHALL BE POWER
WASHED AND CLEANED OF DIRT, DEBRIS
AND OBJECTIONABLE MATERIAL NEAR THE
COMPLETION OF THE WORK IN THE AREA.
3. 5'-0" EMBED OR EMBEDMENT MUST NOT BE
LESS THAN 3'-0" WHEN ENCOUNTERING
ROCK WITH A MINIMUM OF 1-0" EMBED IN
ROCK.
FACES EXPOSED TO
THREAT SHALL BE
NEAR VERTICAL
REMOVE AND DISPOSE OF EXCESS
SOIL OFF OF GOVERNMENT
PROPERTY AS REQUIRED TO
FACILITATE NEW WORK
lhenderson Chip NBAF 8
Jonathan.Lagerquist Text Box G
| T-101 CLIN G-T-101 |
| T-101 CLIN G-T-102 |
| V-101 CLIN G-V-101 |
| C-101 CLIN G-C-101 |
| C-201 CLIN G-C-201 |
| C-501 CLIN G-C-501 |
File details come from the government source that posted it. Updated .