This document is a detailed construction specification and technical drawing set for an asphalt shingle roof replacement and interior repairs project at the Monadnock State Park Hikers Cabin (MD05) located in New Hampshire. The project number is CAP-2505 and involves comprehensive roof rehabilitation, including replacing asphalt shingles, installing new flashing, repairing stone masonry chimney, and performing interior repairs. The technical drawings provide precise installation instructions for roofing materials, including specific guidelines for shingle placement, nailing patterns, cement application, drip edge installation, and chimney flashing details.

The specifications include technical requirements for roof installation using GAF roofing products, with detailed instructions for cold weather applications, ridge cap shingle installation, and leak barrier placement. The project involves replacing the existing roof covering, repairing the stone masonry chimney by re-pointing from the base upward, and performing interior repairs such as replacing drywall and trim. The drawings include multiple technical diagrams showing precise installation methods for shingles, ridge caps, starter courses, and flashing, with specific measurements and placement instructions to ensure proper waterproofing and wind resistance.

View the file

Other files

File Type Posted
rfb-dncr-cap-2505-award.pdf PDF
rfb-dncr-cap-2505.pdf PDF
attachment-1-rfb-dncr-cap-2505.pdf PDF
RFB DNCR CAP-2505.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

ASPHALT SHINGLE ROOF REPLACEMENT

AutoCAD SHX Text

HIKERS CABIN

AutoCAD SHX Text

CAPITAL PROJECTS & MAINTENANCE

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

JAFFREY, NEW HAMPSHIRE

AutoCAD SHX Text

MONADNOCK STATE PARK

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

AUG 29, 2025

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2505

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text NOTES: 1. STRIP AND DISPOSE ALL OF THE STRIP AND DISPOSE ALL OF THE ASPHALT SHINGLE ROOFING INCLUDING UNDERLAYMENTS AND ICE AND WATERSHIELD PROTECTION. 2. REPAIR EXISTING SHEATHING PER REPAIR EXISTING SHEATHING PER ALLOWANCES 3. INSTALL ICE AND WATERSHIELD INSTALL ICE AND WATERSHIELD LEAK BARRIERS. 4. INSTALL DRIP EDGE. INSTALL DRIP EDGE. 5. INSTALL ASPHALT SHINGLE ROOF INSTALL ASPHALT SHINGLE ROOF UNDERLAYMENT. 6. INSTALL ASPHALT SHINGLES. INSTALL ASPHALT SHINGLES. 7. REPOINT STONE MASONRY REPOINT STONE MASONRY CHIMNEY FROM THE FOUNDATION TO CHIMNEY CAP. 8. INSTALL ZINC COATED COPPER INSTALL ZINC COATED COPPER STEP FLASHING AT THE CHIMNEY. 9. REPLACE ALL LEAD COUNTER REPLACE ALL LEAD COUNTER CHIMNEY FLASHING. 10. REPLACE MISSING SHEETROCK IN REPLACE MISSING SHEETROCK IN THE INTERIOR OF THE BUILDING.

AutoCAD SHX Text

1ST COURSE ICE & WATERSHIELD AT EAVES

AutoCAD SHX Text

2ND COURSE ICE & WATERSHIELD AT EAVES

AutoCAD SHX Text

ICE & WATERSHIELD AT RAKES

AutoCAD SHX Text

2ND COURSE ICE & WATERSHIELD AT EAVES

AutoCAD SHX Text

LINE OF BUILDING BELOW

AutoCAD SHX Text 1" x 5" FASCIA TRIM BOARD

AutoCAD SHX Text 2" x 8" FLYING RAFTER

AutoCAD SHX Text

ASPHALT SHINGLES

AutoCAD SHX Text

ICE & WATERSHIELD (2) 36" WIDE COURSES AT EAVES AND RAKES

AutoCAD SHX Text

SHINGLE UNDERLAYMENT ENTIRE ROOF DECK

AutoCAD SHX Text DRIP EDGE 5" DECK FLANGE WITH 1.5" DROP AND " 38" HEMMED DRIP "MILL FINISH" AT EAVES AND RAKES.

AutoCAD SHX Text 2 1

AutoCAD SHX Text

HIKERS CABIN ROOF PLAN

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text 6 1

AutoCAD SHX Text

STONE MASONRY CHIMNEY

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text 4 1

AutoCAD SHX Text

STONE MASONRY CHIMNEY

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text 1 1

AutoCAD SHX Text

MONADNOCK STATE PARK HIKERS CABIN (MOD03)

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text 3 1

AutoCAD SHX Text

DRIPEDGE DETAIL

AutoCAD SHX Text

SCALE: 1" = 1'-0"

AutoCAD SHX Text

REMOVE AND REPLACE ALL LEAD FLASHING WITH NEW 3LB/SQFT LEAD.

AutoCAD SHX Text

REMOVE HAT AND RECONSTRUCT.

AutoCAD SHX Text

RECONSTRUCT CHIMNEY HAT SUPPORTS.

AutoCAD SHX Text

REPOINT STONE MASONRY CHIMNEY FROM ROOFLINE UP.

AutoCAD SHX Text

REMOVE NAILS IN ENDS OF RAFTERS.

AutoCAD SHX Text

3/8" REBAR BOTH WAYS 6" O.C.

AutoCAD SHX Text 7 1

AutoCAD SHX Text

HIKERS CABIN CHIMNEY HAT

AutoCAD SHX Text

SCALE: 1/2" =1'-0"

AutoCAD SHX Text

WIRE TIE AT EACH INTERSECTION

AutoCAD SHX Text

NOTE: PRECAST CHIMNEY HAT CONCRETE SHALL BE 5000 PSI

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

SLOPE

AutoCAD SHX Text

STOVE PIPE PENETRATION

AutoCAD SHX Text

ICE & WATERSHIELD

AutoCAD SHX Text

REPOINT ENTIRE STONE MASONRY CHIMNEY

AutoCAD SHX Text 5 1

AutoCAD SHX Text

STONE MASONRY CHIMNEY

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text

REMOVE CHIMNEY HAT AND RECONSTRUCT.

AutoCAD SHX Text

RECONSTRUCT CHIMNEY HAT SUPPORTS.

AutoCAD SHX Text

REPOINT STONE MASONRY CHIMNEY FROM FOOTING TO TOP.

AutoCAD SHX Text

REMOVE AND REPLACE ALL LEAD COUNTER FLASHING WITH 3LB/SQFT LEAD.

AutoCAD SHX Text

ROCK FROM CHIMNEY HAT SUPPORT.

AutoCAD SHX Text

LOCATE CHIMNEY FOUNDATION BASE AND REPOINT CHIMNEY FROM BASE TO TOP.

AutoCAD SHX Text

3/8" REBAR BOTH WAYS 6" O.C.

AutoCAD SHX Text

APPLY ASPHALT SHINGLES OVER UNDERLAYMENT

AutoCAD SHX Text

APPLY ASPHALT SHINGLES OVER UNDERLAYMENT

AutoCAD SHX Text ASHPHALT SHINGLE ROOF REPLACEMENT AND INTERIOR REPAIRS MONADNOCK STATE PARK HIKERS CABIN (MOD03) 169 POOLE RD. JAFFEREY, NH 03452 PROJECT No. CAP-2505

NOTE: BIDDERS SHALL VERIFY ALL DIMESNIONS BEFORE SUBMITTING A BID AND BEFORE BEGINING ANY WORK. ANY DISCREPANCIES SHOULD BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER FOR CONSIDERATION.

ONE PIECE LEAD BASE FLASHING

(APRON) EXTEND AT LEAST 5" ONTO

ROOF DECK.

USE ONE PIECE LEAD STEP

FLASHING FOR EACH SHINGLE

COURSE. PLACE STEP FLASHING

OVER THE SHINGLE AND NAIL

EACH STEP FLASHING PIECE TO

THE ROOF DECK WITH 2 COPPER

NAILS. SEAL THE OVERLYING

ASPHALT SHINGLES TO THE STEP

FLASHING WITH ASPHALT PLASTIC

CEMENT.

EXTEND LEAD COUNTER FLASHING

OVER BASE FLASHING.

STONE MASONRY CHIMNEY RE-POINT

CHIMNEY FROM THE CHIMNEY BASE UP.

FIRST COURSE

SECOND COURSE

17"

(432mm)

THIRD COURSE

6"

(152mm)11"

(279mm)

FOURTH COURSE

FIFTH COURSE

UNDERLAYMENT

FOURTH COURSE:

THIRD COURSE:

SECOND COURSE:

FIRST COURSE:

PLACE FIRST COURSE OF SHINGLES 1/4"

- 3/4" OVER EAVE AND RAKE EDGES,

COVERING STARTER COURSE

OVERHANG, TO PROVIDE DRIP EDGE.

SHINGLE

INSTALLATION

REMAINING

COURSES:

NOTES:

DRIP EDGE HEM CORNERS

ALUMINUM MIL FINISH DRIP EDGE APPLIED

DIRECT TO THE ROOF DECK AT EAVES

DO NOT SAW CUT STONES FOR

THE LEAD COUNTER FLASHING

INSTALLATION. REUSE THE THE

EXISTING COUNTER FLASHING

LOCATIONS.

ONE PIECE LEAD BASE FLASHING

EXTEND AT LEAST 12" UP THE FACE OF

THE CHIMNEY'S

EXTEND LEAD COUNTER FLASHING

OVER LEAD COATED COPPER BASE

FLASHING.

WRAP CORNERS OF LEAD BASE

FLASHING AT LEAST 3"

ICE & WATERSHIELD

NOTE: DO NOT RUN ICE AND

WATERSHIELD OR OTHER

UNDERLAYMENTS UP THE FACE,

SIDEWALLS, OR BACK OF THE

CHIMNEYS'.

ALUMINUM MILL FINISH DRIP EDGE APPLIED

OVER ICE AND WATERSHIELD AT RAKES

13-1/4" (368 - 445mm)

39-3/8" (1m)

ENHANCED NAILING PATTERN - six nails per shingle*

* required by some local codes and required for enhanced wind coverage on certain products.

See limited warranty for details.

5-3/4" - 6-1/4" (146mm - 159mm) from bottom of shingle

(13 - 64mm) 1/2" - 2-1/2"

(165 - 241mm) 6-1/2" - 9-1/2"

14-1/2" - 17-1/2"

(165 - 241mm) 6-1/2" - 9-1/2"

(368 - 445mm) 14-1/2" - 17-1/2"

Cement locations (4 quarter-sized dabs of cement on back of shingle)

CEMENT

HAND SEALING REQUIRED: TO HAND-SEAL SHINGLES AND TO ENSURE IMMEDIATE

SEALING, APPLY 4 QUARTER-SIZED DABS OF SHINGLE TAB ADHESIVE ON THE BACK OF

THE SHINGLE 1" (25 MM) AND 13" (330 MM) IN FROM EACH SIDE AND

1" (25 MM) UP FROM BOTTOM OF THE SHINGLE. PRESS SHINGLE FIRMLY INTO THE

ADHESIVE.

CAUTION: APPLY ONLY A THIN UNIFORM LAYER OF ASPHALT PLASTIC CEMENT LESS THAN

1/8" (3 MM) THICK. EXCESS AMOUNTS CAN CAUSE BLISTERING OF THE SHINGLES AND MAY

SOFTEN THE ASPHALT IN UNDERLAYMENTS AND LEAK BARRIERS, RESULTING IN THE

ASPHALT DRIPPING AND STAINING.

AutoCAD SHX Text REPLACE R-15 FACED FIBERGLASS INSULATION BATTS. REPLACE 6 MIL-POLYETHYLENE VAPOR BARRIER. REPLACE 1/2" DRYWALL ALONG WALL AND CEILING. TAPE & MUD JOINTS. FINISH SAND AND PRIME COAT "WHITE". INSTALL DOUGLAS FIR TRIM BOARDS 3/8" X 2-3/4" PRE-PAINTED TO MATCH EXISTING GREEN TRIM BOARDS..

AutoCAD SHX Text

INTERIOR 2X4 PARTITION WALL

AutoCAD SHX Text

REPLACE 1/2" SHEETROCK

AutoCAD SHX Text

CEILING AT PEAK

AutoCAD SHX Text

RIDGE AT CEILING

AutoCAD SHX Text

EXISTING LIGHTING FIXTURE

AutoCAD SHX Text

CEILING IS SLOPED AT 4:12

AutoCAD SHX Text 6 2

AutoCAD SHX Text

HIKERS CABIN FLOOR PLAN

AutoCAD SHX Text

SCALE: 1/4" = 1'-0"

AutoCAD SHX Text

LIMIT OF INTERIOR WORK

AutoCAD SHX Text 8 2

AutoCAD SHX Text

HIKERS CABIN INTERIOR

AutoCAD SHX Text

SCALE: N/A

AutoCAD SHX Text 7 2

AutoCAD SHX Text

DRYWALL REPAIRS

AutoCAD SHX Text

SCALE: 1/2" = 1'-0"

AutoCAD SHX Text

REPOINT EXTERIOR STONE MASONRY CHIMNEY

AutoCAD SHX Text REMOVE AND REPLACE INSULATION, & VAPOR BARRIERS WITH NEW R-15 FACED FIBERGLASS BATTS AND 15 MIL POLY VAPOR BARRIER. REPLACE " DRYWALL, 12" DRYWALL, AND WOOD TRIM ALONG CEILING AND WALL. PAINT TO MATCH EXISTING GREEN TRIM BOARDS.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

CAPITAL PROJECTS & MAINTENANCE

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text N/A

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

AUG 29, 2025

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2505

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

CHIMNEY FLASHING DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

TRIM 17" (432MM) OFF FIRST SHINGLE

AutoCAD SHX Text

TRIM 11" (279MM) OFF FIRST SHINGLE

AutoCAD SHX Text

TRIM 6" (152MM) OFF FIRST SHINGLE

AutoCAD SHX Text

START WITH FULL SHINGLE

AutoCAD SHX Text

START AT EITHER RAKE AND LAY IN EITHER DIRECTION

AutoCAD SHX Text

1. CONTINUE EACH COURSE WITH CONTINUE EACH COURSE WITH WHOLE SHINGLES.

AutoCAD SHX Text REPEAT THE 1ST - 4TH COURSE INSTRUCTIONS ON THE REMAINING COURSES, STARTING THE FIFTH COURSE WITH A FULL SHINGLE.

AutoCAD SHX Text

2. STRIKE A CHALK LINEABOUT STRIKE A CHALK LINEABOUT EVERY 6 COURSES TO CHECK PARALLEL ALIGNMENT WITH EAVES.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHINGLE INSTALLATION DETAILS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text Self seal adhesive on back

AutoCAD SHX Text Nail guide line

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GAF ENHANCED NAILING PATTERN

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GAF CEMENT LOCATIONS

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

ROOF REPLACEMENT

AutoCAD SHX Text

HIKERS CABIN

AutoCAD SHX Text

JAFFERY, NEW HAMPSHIRE

AutoCAD SHX Text

MONADNOCK STATE PARK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HAND SEALING DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text NOTES: 1. STRIP AND DISPOSE ALL OF THE STRIP AND DISPOSE ALL OF THE ASPHALT SHINGLE ROOFING INCLUDING UNDERLAYMENTS AND ICE AND WATERSHIELD PROTECTION. 2. REPAIR EXISTING SHEATHING PER REPAIR EXISTING SHEATHING PER ALLOWANCES 3. INSTALL ICE AND WATERSHIELD INSTALL ICE AND WATERSHIELD LEAK BARRIERS. 4. INSTALL DRIP EDGE. INSTALL DRIP EDGE. 5. INSTALL ASPHALT SHINGLE ROOF INSTALL ASPHALT SHINGLE ROOF UNDERLAYMENT. 6. INSTALL ASPHALT SHINGLES. INSTALL ASPHALT SHINGLES. 7. REPOINT STONE MASONRY REPOINT STONE MASONRY CHIMNEY FROM THE FOUNDATION TO CHIMNEY CAP. 8. INSTALL ZINC COATED COPPER INSTALL ZINC COATED COPPER STEP FLASHING AT THE CHIMNEY. 9. REPLACE ALL LEAD COUNTER REPLACE ALL LEAD COUNTER CHIMNEY FLASHING. 10. REPLACE MISSING SHEETROCK IN REPLACE MISSING SHEETROCK IN THE INTERIOR OF THE BUILDING.

AutoCAD SHX Text

REPOINT INTERIOR OF CHIMNEY FROM FLOOR TO CEILING BEFORE INSULATING AND DRYWALL

REPOINT INTERIOR OF CHIMNEY FROM FLOOR TO CEILING BEFORE INSULATION AND DRYWALL.

8"

NAIL APPROXIMATELY 11

2"- 3"

(38 - 76MM) ABOVE THE BUTT

EDGE OF THE SHINGLE AND

APPROXIMATELY 1" - 2" (25 -

51MM) AND 10" - 12" (254 -

305MM) IN FROM OF EACH SIDE

OVERLAP EAVE EDGE STARTER

STRIP AT LEAST 3" (76MM)

FOR MAXIMUM WIND

RESISTANCE ALONG RAKES,

INSTALL GAF STARTER STRIP

SHINGLES AND CEMENT

SHINGLES TO UNDERLAYMENT

AND EACH OTHER IN A 4" (102

MM) WIDTH OF ASPHALT

PLASTIC CEMENT.

TM

TRIM 5" (127MM) FROM END OF FIRST

SHINGLE

START AT EITHER RAKE AND LAY IN EITHER DIRECTION

PLACE STARTER SHINGLE 14"

-3 4" (6 - 19MM) OVER EAVES

AND RAKE EDGES TO

PROVIDE DRIP EDGE.

5"

(127mm)

ALUMINUM DRIP EDGE "WHITE".

6" DECK FLANGE WITH 1-1/2"

FASCIA AND HEMMED 3/8" DRIP.

ALONG

RAKE, PUT

NON-CORROSIVE

METAL DRIP

EDGE

ON TOP OF

SHINGLE-MATE

ROOF DECK

PROTECTION.

SHINGLE-MATE

ROOF DECK

PROTECTION

R

ALONG EAVES, PUT

SHINGLE-MATE ROOF DECK

PROTECTION ON TOP OF

NON-CORROSIVE METAL

DRIP EDGE.

6' min.

(1.83M)

4" END LAP

(102MM)

2" SIDE LAP

(52MM)

R

R

BETWEEN END

LAPS

*USE ICE & WATERSHIELD, WEATHER WATCH ,

STORMGUARD OR OTHER GAF LEAK BARRIER

ON ENTIRE ROOF DECK AS REQUIRED

R

R

12"

36" (914mm)

(305mm)

Perforations

9" (229mm)

12" (305mm)

Sealant

9" (229 mm)

12" (305 mm)

1" (25 mm)

1" (25 mm)

11.5" (292 mm)

Nail

FOR COLD WEATHER APPLICATION

· IN COLD WEATHER, WARM TIMBERTEX® RIDGE CAP SHINGLES

BEFORE BENDING.

· WHEN SELF-SEALING MAY BE DELAYED DUE TO COLD

WEATHER, APPLY QUARTER-SIZED DABS OF ASPHALT

PLASTIC CEMENT (MUST CONFORM TO ASTM D4586 TYPE I OR

TYPE II) BETWEEN RIDGE CAP PIECES AND PRESS FIRMLY TO

INSURE GOOD CONTACT BETWEEN PIECES.

FOR MAXIMUM WIND SPEED COVERAGE UNDER LTD. WARRANTY

· APPLY A 1/4” (6 MM) WIDE BEAD OF HENKEL PL® URETHANE

SEALANT OR SONNEBORN® NP-1™ URETHANE SEALANT TO

EACH RIDGE CAP SHINGLE 3/4”-1” (19MM - 25MM) FROM THE

SHINGLE EDGE, SET PARALLEL TO THE RIDGE (SEE FIGURE 3).

NOTE: EXCESSIVE APPLICATION OF TAB ADHESIVE CAN CAUSE

BLISTERING OF RIDGE CAP SHINGLE.

AutoCAD SHX Text (203mm)

AutoCAD SHX Text

EXPOSURE

AutoCAD SHX Text

NAIL 9" (229MM) FROM BOTTOM AND 1" (25MM) FROM EDGE

AutoCAD SHX Text

SELF-SEAL ADHESIVE ON BACK

AutoCAD SHX Text

BOTTOM BACKER

AutoCAD SHX Text

STARTER COURSE

AutoCAD SHX Text

TOP STRIP

AutoCAD SHX Text

GAF SHINGLE-MATE UNDERLAYMENT OVER ICE & WATERSHIELD ENTIRE ROOF DECK

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

AutoCAD SHX Text

STATE OF NEW HAMPSHIRE

AutoCAD SHX Text

DEPARTMENT OF NATURAL AND CULTURAL RESOURCES

AutoCAD SHX Text

OF

AutoCAD SHX Text

AutoCAD SHX Text

EDWARD MUSSEY

AutoCAD SHX Text

APPROVED BY:

AutoCAD SHX Text

DRAWN BY:

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

AUG 29, 2025

AutoCAD SHX Text

PROJECT #

AutoCAD SHX Text

CAP-2505

AutoCAD SHX Text

ROOF REPLACEMENT

AutoCAD SHX Text NOTES: 1. STRIP AND DISPOSE STRIP AND DISPOSE ALL ASPHALT SHINGLE ROOFING AND DRIP EDGE. 2. INSTALL ICE & INSTALL ICE & WATERSHIELD ON ENTIRE ROOF DECK & ALONG EAVES, RAKES AND VALLEYS. 3. INSTALL DRIPEDGE. INSTALL DRIPEDGE. 4. INSTALL ASPHALT INSTALL ASPHALT SHINGLES. 5. PROVIDE INSTALLERS & PROVIDE INSTALLERS & SHINGLE MANUFACTURER WARRANTIES.

AutoCAD SHX Text NOTES: 1. LEAK BARRIER'S SHALL BE APPLIED IN FAIR LEAK BARRIER'S SHALL BE APPLIED IN FAIR WEATHER WHEN THE AIR, ROOF DECK, AND MEMBRANE ARE AT TEMPERATURES OF 40 F OR HIGHER. ROOF COVERING MATERIAL SHALL BE APPLIED AT TEMPERATURES OF 40 F OR HIGHER.

AutoCAD SHX Text

GAF TIMBERTEX RIDGE CAP 12" IN "WEATHERD WOOD"

AutoCAD SHX Text

COBRA SNOW COUNTRY ADVANCED RIDGE VENT 11.5" (292 MM)

AutoCAD SHX Text

GAF UHDZ SHINGLES IN "WEATHERED WOOD"

AutoCAD SHX Text

GAF SHINGLEMATE

AutoCAD SHX Text

ICE & WATERSHIELD ENTIRE ROOF DECK

AutoCAD SHX Text

EXISTING 5/8" PLYWOOD DECKING

AutoCAD SHX Text

EXISTING TRUSS

AutoCAD SHX Text NOTE: USE SUPPLIED 3" (76 MM) CORROSION RESISTANT RING SHANK NAILS INCLUDED WITH THE RIDGE VENT.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

HIKERS CABIN

AutoCAD SHX Text

CAPITAL PROJECTS & MAINTENANCE

AutoCAD SHX Text

STEWARTSTOWN, NEW HAMPSHIRE

AutoCAD SHX Text

COLEMAN STATE PARK

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

TIMBERTEX INSTALLATION DETAIL

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

PROSTART INSTALLATION

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SHINGLE-MATE INSTALLATION DETAIL 4:12 OR MORE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

RIDGE VENT DETAIL (TYPICAL)

NOT TO SCALE

Sheets and Views
CAP-2505 HIKERS CABIN ROOFING-SHEET 1
CAP-2505 HIKERS CABIN ROOFING-SHEET 2
CAP-2505 HIKERS CABIN ROOFING-SHEET 3

File details come from the government source that posted it. Updated .