This document provides details on a federal contract opportunity for construction services. The Department of Veterans Affairs Office of Information Service Center is soliciting proposals under solicitation number 36C77622R0121 for the construction of a parking garage in West Haven, Connecticut. Interested parties should respond to the design-bid-build request for proposals no later than the date specified for consideration. The opportunity involves building a new parking garage to serve the VA facility located in West Haven. Proposals should include pricing and schedules to complete the defined scope of work for the garage construction project. Relevant drawings are provided as an attachment to inform proposal responses.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DIRECTOR DATE
CHIEF OF FACILITIES MANAGEMENT SERVICE DATE
PROJECT MANAGER DATE
DEPUTY DIRECTOR DATE
CHIEF OF DESIGN AND DEVELOPMENT DATE
CHIEF OF SAFETY DATE
CHIEF OF POLICE DATE
PROJECTION LOCATION
PROJECTION LOCATION
PARKING EFFICIENCY = 340SF/SPACE
STANDARD SPACE = 9'-0" X 18'-0" @ 90°
ADA = 9'-0" X 18'-0" W/5'-0" ACCESIBLE AISLES @ 90°
ADA VAN ACCESSIBLE = 11'-0" X 18'-0" W/5'-0" ACCESIBLE AISLES @ 90°
PROJECTION LOCATION
STATEMENT OF BID ITEMS
A. BID DEDUCT A - LANDSCAPING
LANDSCAPING ALONG THE NORTHEAST FENCE OF THE GARAGE SHALL
REMAIN. REMOVE ALL OTHER FOUNDATION PLANTINGS FROM THE BASE
BID, PER SHEET PL102.
B. BID DEDUCT B - CAR COUNT EQUIPMENT
IN ADDITION TO BID DEDUCT A, ELIMINATE CAR COUNT EQUIPMENT AT
BOTH ENTRANCES AND NECESSARY SUPPORT EQUIPMENT THROUGHOUT
THE GARAGE. REFER TO SHEET AP511 AND COORDINATE WITH
ENGINEERING DRAWINGS.
C. BID DEDUCT C - ELEVATOR
IN ADDITION TO BID DEDUCT A AND B, ELIMINATE ONE ELEVATOR AND ALL
NECESSARY EQUIPMENT, ONE DUCTLESS SPLIT SYSTEM HEATPUMP IN
ROOM 105, AND FINISH WORK. ELEVATOR SHAFT TO REMAIN. REFER TO
SHEETS AE101 THROUGH AE105 AND COORDINATE WITH ENGINEERING
DRAWINGS.
D. BID DEDUCT D - SECTION OF PARKING GARAGE
IN ADDITION TO BID DEDUCTS A, B, AND C, ELIMINATE LEVEL 5 (WEST) AND
ALL ASSOCIATED ITEMS BETWEEN COLUMN LINES A1 TO B7, REMOVE ONE
LEVEL OF WEST STAIR TOWER. ELIMINATE CONCRETE DOUBLE T'S AND
TOPPING SLAB, SPANDRELS AND BEAMS FROM COLUMN LINES A1 TO B7
AND ALL ASSOCIATED WASHES, FINISHES AND DIV. 07 WORK
(WATERPROOFING) PERTAINING TO THIS REMOVED PORTION. REDUCE
HEIGHT BY 11'-4" FOR EACH COLUMN LOCATED ON COLUMN LINES 1
THROUGH 7 AND A THROUGH B. ELIMINATE THE CABLE BARRIER ON
COLUMN LINE B2 TO B7.
REVISE SCUPPER & DOWNSPOUT, LIGHTING, STANDPIPE AND POWER TO
COORDINATE WITH ROOF INSTALLED AT ALTERNATE HEIGHT/LEVEL.
REMOVE DOOR 504a AND ASSOCIATED HARDWARE. ALL POLE-MOUNTED
LIGHTING, ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID LIGHTING ON LEVEL
4 (WEST).
ALL POWER ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID POWER ON LEVEL 4
(WEST).
ALL PLUMBING ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID PLUMBING ON
LEVEL 4 (WEST).
ALL FIRE PROTECTION ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID FIRE
PROTECTION ON LEVEL 4 (WEST).
ALL SECURITY ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID SECURITY ON
LEVEL 4 (WEST).
ALL TECHNOLOGY ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID
TECHNOLOGY ON LEVEL 4 (WEST).
ELIMINATE SIGNAGE ASSOCIATED WITH ELIMINATED PORTION OF LEVEL 5
(WEST) STAIR 504.
BID DEDUCT SHALL BE COORDINATED WITH ALL DISCIPLINES.
E. BID DEDUCT E - REMOVE SECTION OF PARKING GARAGE
IN ADDITION TO BID DEDUCTS A, B, C, AND D, ELIMINATE LEVEL 4 AND ALL
ASSOCIATED ITEMS BETWEEN COLUMN LINES A7 TO C8 AND B1 TO C7,
REMOVE ONE LEVEL OF EAST STAIR/ELEVATOR TOWER. ELIMINATE
CONCRETE DOUBLE T'S AND TOPPING SLAB, SPANDRELS AND BEAMS
FROM COLUMN LINES A7 TO C8 AND B1 TO C7 AND ALL ASSOCIATED
WASHES, FINISHES AND DIV. 07 WORK (WATERPROOFING). REDUCE
HEIGHT BY 11'-4" FOR EACH COLUMN LOCATED ON COLUMN LINES 1
THROUGH 8 AND A THROUGH C. ELIMINATE THE CABLE BARRIER ON
COLUMN LINE B2 TO B7.
REVISE SCUPPER & DOWNSPOUT, LIGHTING, STANDPIPE AND POWER TO
COORDINATE WITH ROOF INSTALLED AT ALTERNATE HEIGHT. REMOVE
DOOR 501a AND ASSOCIATED HARDWARE. ALL LIGHTING, ASSOCIATED
WITH ELIMINATED PORTION OF THE GARAGE IS RELOCATED TO LEVEL 3, IN
LIEU OF BASE BID LIGHTING ON LEVEL 3.
ALL POWER ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 3, IN LIEU OF BASE BID POWER ON LEVEL 3.
ALL PLUMBING ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID PLUMBING ON LEVEL 3.
ALL FIRE PROTECTION ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID FIRE
PROTECTION ON LEVEL 3.
ALL SECURITY ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID SECURITY ON LEVEL 3.
ALL TECHNOLOGY ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID TECHNOLOGY
ON LEVEL 3.
ELIMINATE SIGNAGE ASSOCIATED WITH ELIMINATED PORTION OF LEVEL 4
STAIR 401.
BID DEDUCT SHALL BE COORDINATED WITH ALL DISCIPLINES.
BASE BID: IS THE FULL CONSTRUCTION OF THE PROPOSED PARKING
GARAGE AS REPRESENTED IN THE CONSTRUCTION DRAWINGS: WORK
INCLUDES GENERAL CONSTRUCTION, ALTERNATIONS, ROADS, WALKS,
GRADING, DRAINAGE, FOUNDATIONS AND CONSTRUCTION OF NEW PRE-
CAST PARKING GARAGE, AND ALL OF ITS ELEMENTS AS WELL AS
NECESSARY REMOVAL OF EXISTING STRUCTURES, CONSTRUCTION, AND
CERTAIN OTHER ITEMS.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\j jo n e s \D o c u m e n ts
\2
.1
A v jjo n e s
J S
C .r v t
/6
/2
:5
:2
P
M
GI000
COVER SHEET
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
689-409
FACILITIES MANAGEMENT
11/30/2021 ARO JDJ
689-409
WEST HAVEN PARKING GARAGE
VA CONNECTICUT HEALTHCARE SYSTEM
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
100% CONSTRUCTION DOCUMENTS
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
856.429.4000
SHEET INDEX
SHEET NUMBER SHEET NAME
GENERAL
GI000 COVER SHEET
GI101 CODE ANALYSIS AND LIFE SAFETY PLANS
GC102 BID DEDUCTS
CIVIL
CI001 CIVIL NOTES AND LEGEND
CI002 PHASING PLAN - PHASE 1
CI003 PHASING PLAN - PHASE 2
CI004 PHASING PLAN - PHASE 3
CI501 MAITENANCE OF TRAFFIC DETAILS
CD101 DEMOLITION PLAN
CS101 SITE PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CG101 GRADING PLAN
CU101 UTILITY PLAN
CU201 PLAN AND PROFILE - STORM SEWER PROFILE
CU202 PLAN AND PROFILE - ELECTRICAL DUCT BANK
CU203 PLAN AND PROFILE - ELECTRICAL DUCT BANK
CU204 PLAN AND PROFILE - SANITARY SEWER
CU501 UTILITY DETAILS
CU502 UTILITY DETAILS
CU503 UTILITY DETAILS
CJ101 EROSION CONTROL PLAN
CJ501 EROSION CONTROL DETAILS
LP101 PLANTING PLAN
LP102 PLANTING PLAN DEDUCT
LP501 LANDSCAPE DETAILS
STRUCTURAL
SI001 STRUCTURAL SYMBOLS AND ABBREVIATIONS
SI002 STRUCTURAL GENERAL NOTES
SI003 LOAD MAPS AND DESIGN DATA
SB101 FOUNDATION PLAN
SB401 ENLARGED FOUNDATION PLANS
SB501 FOUNDATION SECTIONS AND DETAILS
SB502 FOUNDATION SECTIONS AND DETAILS
SF101 SLAB-ON-GRADE PLAN
SF102 LEVEL 2 FRAMING PLAN
SF103 LEVEL 3 FRAMING PLAN
SF104 LEVEL 4 FRAMING PLAN
SF105 LEVEL 5 FRAMING PLAN
SF201 BUILDING ELEVATIONS
SF202 BUILDING ELEVATIONS
SF203 SHEARWALL ELEVATIONS
SF204 PRECAST WALL ELEVATIONS
SF401 ENLARGED FRAMING PLANS - STAIR 1 AND 2
SF402 ENLARGED FRAMING PLANS - ENTRANCE CANOPIES
SF501 FRAMING SECTIONS AND DETAILS
SF502 FRAMING SECTIONS AND DETAILS
SF503 FRAMING SECTIONS AND DETAILS
SF901 ISOMETRICS
ARCHITECTURAL
AE001 ARCHITECTURAL SYMBOLS AND ABBREVIATIONS
AE101 LEVEL 1 ARCHITECTURAL PLAN
AE102 LEVEL 2 ARCHITECTURAL PLAN
AE103 LEVEL 3 ARCHITECTURAL PLAN
AE104 LEVEL 4 ARCHITECTURAL PLAN
AE105 LEVEL 5 ARCHITECTURAL PLAN
AE106 ROOF PLAN
AE201 BUILDING ELEVATIONS
AE202 ENLARGED ELEVATIONS
AE301 BUILDING SECTIONS
AE311 WALL SECTIONS
AE320 EAST STAIR SECTIONS
AE321 EAST STAIR AND ELEVATOR SECTIONS
AE322 EAST STAIR AND ELEVATOR SECTIONS
AE323 WEST STAIR SECTIONS
AE324 WEST STAIR SECTIONS AND DETAILS
AE325 ELEVATOR ELEVATION AND SIGNAGE
AE326 STAIR TOWER ISOMETRICS
AE401 ENLARGED PLANS
AE501 BUILDING DETAILS
AE601 DOOR SCHEDULE
AE602 STOREFRONT ELEVATIONS AND DETAILS
FUNCTIONAL
AP101 LEVEL 1 STRIPING, SIGNAGE AND WATERPROOFING PLAN
AP102 LEVEL 2 STRIPING, SIGNAGE AND WATERPROOFING PLAN
AP103 LEVEL 3 STRIPING, SIGNAGE AND WATERPROOFING PLAN
AP104 LEVEL 4 STRIPING, SIGNAGE AND WATERPROOFING PLAN
AP105 LEVEL 5 STRIPING, SIGNAGE AND WATERPROOFING PLAN
AP501 STRIPING AND PAINTED GRAPHICS DETAILS
AP511 SIGNAGE SCHEDULE AND DETAILS
AP512 SIGNAGE SCHEDULE AND DETAILS
AP513 WATERPROOFING DETAILS
FIRE PROTECTION
FX001 FIRE PROTECTION DETAILS, NOTES AND LEGEND
FX101 FIRE PROTECTION PLAN - LEVEL 1
FX102 FIRE PROTECTION PLAN - LEVELS 2 TO 4
FX105 FIRE PROTECTION PLAN - PARTIAL LEVEL 4 & LEVEL 5
FX301 FIRE PROTECTION SECTIONS
PLUMBING
PP001 PLUMBING - ABBREVIATIONS, NOTES & SYMBOLS
PP101 PLUMBING PLAN - LEVEL 1
PP102 PLUMBING PLAN - LEVELS 2 TO 4
PP105 PLUMBING PLAN - PARTIAL LEVEL 4 & LEVEL 5
PP301 PLUMBING SECTIONS
PP501 PLUMBING DETAILS AND SCHEDULES
MECHANICAL
MI001 MECHANICAL ABBREVIATIONS, NOTES, & SYMBOLS
MH101 MECHANICAL PLAN - LEVEL 1
MH102 MECHANICAL PLAN - PARTIAL LEVEL 4 & LEVEL 5
MI701 MECHANICAL SCHEDULES
MI702 MECHANICAL DETAILS
ELECTRICAL
EI001 ELECTRICAL ABBREVIATIONS & SYMBOLS
EI002 ELECTRICAL NOTES
ES101 ELECTRICAL PLAN SITE
EY101 ELECTRICAL SYSTEMS PLAN - LEVEL 1
EY102 ELECTRICAL SYSTEMS PLAN - LEVELS 2 TO 4
EY105 ELECTRICAL SYSTEMS PLAN - PARTIAL LEVEL 4 & LEVEL 5
EL101 ELECTRICAL LIGHTING PLAN - LEVEL 1
EL102 ELECTRICAL LIGHTING PLAN - LEVELS 2 TO 4
EL105 ELECTRICAL LIGHTING PLAN - PARTIAL LEVEL 4 & LEVEL 5
EP001 ELECTRICAL BUILDING 2 WORK PLAN
EP101 ELECTRICAL POWER PLAN - LEVEL 1
EP102 ELECTRICAL POWER PLAN - LEVELS 2 TO 4
EP105 ELECTRICAL POWER PLAN - PARTIAL LEVEL 4 & LEVEL 5
FA101 FIRE ALARM PLAN - LEVEL 1
FA102 FIRE ALARM PLAN - LEVELS 2 TO 4
FA105 FIRE ALARM PLAN - PARTIAL LEVEL 4 & LEVEL 5
EI501 ELECTRICAL DETAILS
EI502 ELECTRICAL DETAILS
EI503 ELECTRICAL DETAILS
EI504 ELECTRICAL DETAILS
EI601 ELECTRICAL SINGLE LINE DIAGRAM
EI602 ELECTRICAL SCHEDULES
Contact:Contact:Contact:Contact: Contact:
MILLER REMICK
Benjamin Harless
PE
MECHANICAL,
ELECTRICAL &
PLUMBING
GUIDON DESIGN INC.
Mark VanderWoude
PE
STRUCTURAL
ENGINEER
GUIDON DESIGN INC.
Stacey Paul
Project Manager, PE
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 104 e: spaul@guidondesign.com
CIVIL
ENGINEER
VA WEST HAVEN MEDICAL CENTER
Joseph Simonetta
COR
950 Campbell Avenue West Haven, CT 06516 p: 203.500.2186 e: joseph.simonetta2@va.gov
OWNER
GUIDON DESIGN INC.
Adam Ogrzewalla
Architect
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 103 e: aogrzewalla@guidondesign.com
ARCHITECT
1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 x 119 e: mvanderwoude@guidondesign.com
1010 Kings Highway South Building Two - 2nd Floor Cherry Hill, NJ 08034 p: 856.429.4000 e: bharless@miller-remick.com
AREA MAP
VICINITY MAP
CAMPUS MAP
GARAGE PARKING SUMMARY
DESCRIPTION COUNT
LEVEL 1
ADA VAN ACCESSIBLE PARKING SPACE 3
PARKING SPACE 92
LEVEL 2
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 3
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 4
ADA PARKING SPACE 9
PARKING SPACE 92
LEVEL 5 - WEST
PARKING SPACE 5
GARAGE TOTAL: 403
Revisions: Date:
UP
DN
1 2 3 4 5 6 7 8
A
B
C
1.5
31162 SF
200156
S
DISTANCE BETWEEN EXITS = 250'-8"
DIAGONAL DISTANCE = 296'-10"
M A
X T
R A
V E
L D
IS
T
A N
C E
'-1
"134 SF
S
134 SF
S
343 SF
S
173 SF
S
FECFEC FEC
EXIT
EXIT
B.6
ELECTRICAL
SECURITY
OIT
STORAGE
WEST STAIR
104 LEVEL 1 - LOBBY
ELEV 2
ELEV 1
102EAST STAIR
ELEV. CONTROLS
346 SF
S
99 SF
S
1 2 3 4 5 6 7 8
A
B
C
1.5
32219 SF
200162
S
173 SF
S
DISTANCE BETWEEN EXITS = 250'-8"
DIAGONAL DISTANCE = 296'-10"
M A
X T
R A
V E
L D
IS
T
A N
C E
'-9
FECFEC FEC
FEC
EXIT
EXIT
B.6
WEST STAIR
EAST STAIR
LEVEL 2 - LOBBY
ELEV 2
ELEV 1
1 2 3 4 5 6 7 8
A
B
C
1.5
32219 SF
200162
S
173 SF
S
DISTANCE BETWEEN EXITS = 250'-8"
DIAGONAL DISTANCE = 296'-10"
M A
X T
R A
V E
L D
IS
T
A N
C E
'-9
FECFEC FEC
FEC
EXIT
EXIT
B.6
WEST STAIR
LEVEL 3 - LOBBY
EAST STAIR
ELEV 1
ELEV 2
1 2 3 4 5 6 7 8
A
B
C
1.5
32219 SF
200162
S
173 SF
S
DISTANCE BETWEEN EXITS = 250'-8"
DIAGONAL DISTANCE = 296'-10"
M A
X T
R A
V E
L D
IS
T
A N
C E
'-9
FECFEC FEC
FEC
EXIT
EXIT
B.6
ELEV 2
ELEV 1
LEVEL 4 - LOBBY
EAST STAIR
WEST STAIR
TOTAL OCCUPANCY
FEC
EXIT
OCCUPANCY LOAD FACTOR
EXITS REQUIRED
SQUARE FOOTAGE
OCCUPANCY TYPE
EGRESS EXIT SIGNAGE
FIRE EXTINGUISHER CABINET
DIAGONAL DISTANCE
EXIT SEPARATION DISTANCE
EGRESS PATH
2 HR - FIRE SEPARATION
1 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREA
B
1500 SF
CODE ANALYSIS LEGEND
BUILDING CODES
VA DESIGN MANUALS PG-18-10
BUILDING CODE PROJECT ANALYSIS
1 2 3 4 5 6 7 8
A
B
C
1.5
B.6
DISTANCE BETWEEN EXITS = 250'-8"
DIAGONAL DISTANCE = 296'-10"
MAX TRAVEL DISTANCE = 61'-0"
FEC FEC
EXIT
2568 SF
20013
S
WEST STAIR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\j jo n e s \D o c u m e n ts
\2
.1
A v jjo n e s
J S
C .r v t
/6
/2
:5
:3
P
M
GI101
CODE ANALYSIS AND LIFE SAFETY
PLANSGUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
689-409
FACILITIES MANAGEMENT
11/30/2021 AO JDJ
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
856.429.4000
LIFE SAFETY OCCUPANCY COUNT
AREA SF OCC OCC FACTOR # OF OCC
Not Placed
ELECTRICAL Not Placed S 200 2
CONTROL RM Not Placed S 200 1
LEVEL 1
PARKING 31162 SF S 200 156
SECURITY 134 SF S 200 1
OIT 134 SF S 200 1
STORAGE 343 SF S 200 2
LOBBY 173 SF S 200 1
ELECTRICAL 346 SF S 200 2
ELEV. CONTROLS 99 SF S 200 1
LEVEL 2
PARKING 32219 SF S 200 162
LOBBY 173 SF S 200 1
LEVEL 3
PARKING 32219 SF S 200 162
LOBBY 173 SF S 200 1
LEVEL 4
PARKING 32219 SF S 200 162
LOBBY 173 SF S 200 1
LEVEL 5 - WEST
PARKING 2568 SF S 200 13
132136 SF 669
SCALE: 3/64" = 1'-0"GI101
2 LEVEL 1
SCALE: 3/64" = 1'-0"GI101
3 LEVEL 2
SCALE: 3/64" = 1'-0"GI101
4 LEVEL 3
SCALE: 3/64" = 1'-0"GI101
5 LEVEL 4
GROSS BUILDING AREA
FLOOR SF
LEVEL 1
GROSS FLOOR AREA 33630 SF
LEVEL 2
GROSS FLOOR AREA 33630 SF
LEVEL 3
GROSS FLOOR AREA 33630 SF
LEVEL 4
GROSS FLOOR AREA 33630 SF
LEVEL 5 - WEST
GROSS FLOOR AREA 2875 SF
137394 SF
LEVEL 4
EL 134'-0"
LEVEL 3
EL 122'-8"
LEVEL 2
EL 111'-4"
LEVEL 1
EL 100'-0"
LEVEL 4 - WEST
EL 128'-0"
LEVEL 3 - WEST
EL 116'-8"
LEVEL 2 - WEST
EL 105'-4"
LEVEL 1 - WEST
EL 94'-0"
LEVEL 5 - WEST
EL 139'-4"
ISOMETRIC VIEW KEY
SCALE: 3/64" = 1'-0"GI101
6 LEVEL 5
UP
1 2 3 4 5 6 7 8
A
B
C
1.5
B.6
C
1 2 3 4 5 6 7 8
A
B
C
1.5
B.6
D
E
E X
T E
N T
O F
B
ID
D E
D U
C T
D
A P
P R
O X
. 6 2'
EXTENT OF BID DEDUCT "D"
APPROX. 226' - 0"
E X
T E
N T
O F
B
ID
D E
D U
C T
E
A P
P R
O X
. 1
1/
2"
EXTENT OF BID DEDUCT "E"
APPROX. 54' - 10"
E X
T E
N T
O F
B
ID
D E
D U
C T
E
A P
P R
O X
. 6 2'
EXTENT OF BID DEDUCT "E"
APPROX. 272' - 0"
BID DEDUCT "D"
PARKING SPACE REDUCTION:
TOTAL = 45 (STANDARD SPACES)
BID DEDUCT "E"
PARKING SPACE REDUCTION:
TOTAL = 56 (47 STANDARD & 9 ADA SPACES)
STATEMENT OF BID ITEMS
A. BID DEDUCT A - LANDSCAPING
LANDSCAPING ALONG THE NORTHEAST FENCE OF THE GARAGE SHALL
REMAIN. REMOVE ALL OTHER FOUNDATION PLANTINGS FROM THE BASE
BID, PER SHEET PL102.
B. BID DEDUCT B - CAR COUNT EQUIPMENT
IN ADDITION TO BID DEDUCT A, ELIMINATE CAR COUNT EQUIPMENT AT
BOTH ENTRANCES AND NECESSARY SUPPORT EQUIPMENT THROUGHOUT
THE GARAGE. REFER TO SHEET AP511 AND COORDINATE WITH
ENGINEERING DRAWINGS.
C. BID DEDUCT C - ELEVATOR
IN ADDITION TO BID DEDUCT A AND B, ELIMINATE ONE ELEVATOR AND ALL
NECESSARY EQUIPMENT, ONE DUCTLESS SPLIT SYSTEM HEATPUMP IN
ROOM 105, AND FINISH WORK. ELEVATOR SHAFT TO REMAIN. REFER TO
SHEETS AE101 THROUGH AE105 AND COORDINATE WITH ENGINEERING
DRAWINGS.
D. BID DEDUCT D - SECTION OF PARKING GARAGE
IN ADDITION TO BID DEDUCTS A, B, AND C, ELIMINATE LEVEL 5 (WEST) AND
ALL ASSOCIATED ITEMS BETWEEN COLUMN LINES A1 TO B7, REMOVE ONE
LEVEL OF WEST STAIR TOWER. ELIMINATE CONCRETE DOUBLE T'S AND
TOPPING SLAB, SPANDRELS AND BEAMS FROM COLUMN LINES A1 TO B7
AND ALL ASSOCIATED WASHES, FINISHES AND DIV. 07 WORK
(WATERPROOFING) PERTAINING TO THIS REMOVED PORTION. REDUCE
HEIGHT BY 11'-4" FOR EACH COLUMN LOCATED ON COLUMN LINES 1
THROUGH 7 AND A THROUGH B. ELIMINATE THE CABLE BARRIER ON
COLUMN LINE B2 TO B7.
REVISE SCUPPER & DOWNSPOUT, LIGHTING, STANDPIPE AND POWER TO
COORDINATE WITH ROOF INSTALLED AT ALTERNATE HEIGHT/LEVEL.
REMOVE DOOR 504a AND ASSOCIATED HARDWARE. ALL POLE-MOUNTED
LIGHTING, ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID LIGHTING ON LEVEL
4 (WEST).
ALL POWER ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID POWER ON LEVEL 4
(WEST).
ALL PLUMBING ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID PLUMBING ON
LEVEL 4 (WEST).
ALL FIRE PROTECTION ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID FIRE
PROTECTION ON LEVEL 4 (WEST).
ALL SECURITY ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID SECURITY ON
LEVEL 4 (WEST).
ALL TECHNOLOGY ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 4 (WEST), IN LIEU OF BASE BID
TECHNOLOGY ON LEVEL 4 (WEST).
ELIMINATE SIGNAGE ASSOCIATED WITH ELIMINATED PORTION OF LEVEL 5
(WEST) STAIR 504.
BID DEDUCT SHALL BE COORDINATED WITH ALL DISCIPLINES.
E. BID DEDUCT E - REMOVE SECTION OF PARKING GARAGE
IN ADDITION TO BID DEDUCTS A, B, C, AND D, ELIMINATE LEVEL 4 AND ALL
ASSOCIATED ITEMS BETWEEN COLUMN LINES A7 TO C8 AND B1 TO C7,
REMOVE ONE LEVEL OF EAST STAIR/ELEVATOR TOWER. ELIMINATE
CONCRETE DOUBLE T'S AND TOPPING SLAB, SPANDRELS AND BEAMS
FROM COLUMN LINES A7 TO C8 AND B1 TO C7 AND ALL ASSOCIATED
WASHES, FINISHES AND DIV. 07 WORK (WATERPROOFING). REDUCE
HEIGHT BY 11'-4" FOR EACH COLUMN LOCATED ON COLUMN LINES 1
THROUGH 8 AND A THROUGH C. ELIMINATE THE CABLE BARRIER ON
COLUMN LINE B2 TO B7.
REVISE SCUPPER & DOWNSPOUT, LIGHTING, STANDPIPE AND POWER TO
COORDINATE WITH ROOF INSTALLED AT ALTERNATE HEIGHT. REMOVE
DOOR 501a AND ASSOCIATED HARDWARE. ALL LIGHTING, ASSOCIATED
WITH ELIMINATED PORTION OF THE GARAGE IS RELOCATED TO LEVEL 3, IN
LIEU OF BASE BID LIGHTING ON LEVEL 3.
ALL POWER ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE IS
RELOCATED TO LEVEL 3, IN LIEU OF BASE BID POWER ON LEVEL 3.
ALL PLUMBING ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID PLUMBING ON LEVEL 3.
ALL FIRE PROTECTION ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID FIRE
PROTECTION ON LEVEL 3.
ALL SECURITY ASSOCIATED WITH ELIMINATED PORTION OF THE GARAGE
IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID SECURITY ON LEVEL 3.
ALL TECHNOLOGY ASSOCIATED WITH ELIMINATED PORTION OF THE
GARAGE IS RELOCATED TO LEVEL 3, IN LIEU OF BASE BID TECHNOLOGY
ON LEVEL 3.
ELIMINATE SIGNAGE ASSOCIATED WITH ELIMINATED PORTION OF LEVEL 4
STAIR 401.
BID DEDUCT SHALL BE COORDINATED WITH ALL DISCIPLINES.
BASE BID: IS THE FULL CONSTRUCTION OF THE PROPOSED PARKING
GARAGE AS REPRESENTED IN THE CONSTRUCTION DRAWINGS: WORK
INCLUDES GENERAL CONSTRUCTION, ALTERNATIONS, ROADS, WALKS,
GRADING, DRAINAGE, FOUNDATIONS AND CONSTRUCTION OF NEW PRE-
CAST PARKING GARAGE, AND ALL OF ITS ELEMENTS AS WELL AS
NECESSARY REMOVAL OF EXISTING STRUCTURES, CONSTRUCTION, AND
CERTAIN OTHER ITEMS.
NOTE: REFERENCE BID ALTERNATE DESCRIPTION FOR MORE INFORMATION.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
Consultant:
C U s e rs
\j jo n e s \D o c u m e n ts
\2
.1
A v jjo n e s
J S
C .r v t
/6
/2
:5
:2
P
M
GC102
BID DEDUCTS
GUIDON
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
950 CAMPBELL AVENUE, WEST HAVEN, CT 06516
689-409
FACILITIES MANAGEMENT
11/30/2021 AO JDJ
100% CONSTRUCTION
DOCUMENTS
NON-SPRINKLERED
856.429.4000
SCALE: 1/16" = 1'-0"GC102
1 LEVEL 1 ARCHITECTURAL PLAN - BID DEDUCT "C"
SCALE: 1/16" = 1'-0"GC102
2 ROOF PLAN - BID DEDUCT "D" & "F"
SCALE: 12" = 1'-0"GC102
3 PL-13 PARKING AVAILABLITY SIGN - BID DEDUCT "B"
LEVEL 4
EL 139'-0 3/4"
LEVEL 3
EL 127'-8 3/4"
LEVEL 2
EL 116'-4 3/4"
LEVEL 1
EL 105'-0 3/4"
LEVEL 4 - WEST
EL 133'- 0 3/4"
LEVEL 3 - WEST
EL 121'- 8 3/4"
LEVEL 2 - WEST
EL 110'- 4 3/4"
LEVEL 1 - WEST
EL 99'-0 3/4"
LEVEL 5 - WEST
EL 144'- 4 3/4"
ISOMETRIC VIEW KEY
CI001
CIVIL NOTES AND LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CI002
PHASING PLAN - PHASE 1
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
ACCESS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CI003
PHASING PLAN - PHASE 2
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CI004
PHASING PLAN - PHASE 3
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
ACCESS
TEMPORARY
PEDESTRIAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CI501
MAINTENANCE OF TRAFFIC
DETAILS
ROAD CLOSED
THRU TRAFFIC
TO
END
DETOUR
DETOUR DETOUR DETOUR
ONE
WAY
ONE
WAY NO
PARKING
DO NOT
ENTER ONLY
TO PATIENT
PICKUP
TO PATIENT
PICKUP
TO PATIENT
PICKUP
PATIENT
DROPOFF
ONLY
DETOUR DETOUR DETOUR
TO PATIENT
PARKING
TO PATIENT
PARKING
TO PATIENT
PARKING
NOT AN
ACCESSIBLE
ROUTE
GENERAL
PATIENT
PARKING
ACCESSIBLE
PATIENT
PARKING
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CD101
DEMOLITION PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CS101
SITE PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CS501
SITE DETAILS
PUSH
BUTTON
FOR
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CS502
SITE DETAILS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CG101
GRADING PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CU101
UTILITY PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CU201
PLAN AND PROFILE -
STORM SEWER
N
0 4020
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CU202
PLAN AND PROFILE -
STORM SEWER
N
0 4020
N
0 4020
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CU203
PLAN AND PROFILE -
ELECTRICAL DUCT BANK
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CU204
PLAN AND PROFILE -
SANITARY SEWER
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CU501
UTILITY DETAILS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CU502
UTILITY DETAILS
Phone (888) 344-9044 Fax (423) 826-2112 2705 Kanasita Drive, Chattanooga, TN 37343
STORMWATER TREATMENT SOLUTIONS
www.aquashieldinc.com Aqua-Swirl Concentrator Model AS-4 PCS Standard Detail
AS-4 PCS STD
01/12/11 Scale:
Drawn By:
Document:
Date:
JCW
1:20
U.S. Patent No. 6524473 and other Patent Pending
* Please see accompanied Aqua-Swirl specification notes.
* See Site Plan for actual system orientation.
** Orientation may vary from 90°, 180°, or custom angles to meet site conditions.
A
In le t Outlet
A
Pipe coupling by Contractor.
12" long Stub-out by Manufacturer.
Pipe coupling by Contractor.
12" long Stub-out by Manufacturer.
Vent
Arched Baffle
Octagonal Base Plate
STORMWATER TREATMENT SOLUTIONS
Phone (888) 344-9044 www.aquashieldinc.com
Vent
Arched Baffle
Slide riser over top ring and bolt in 4 placesRiser
Swirl Inlet Swirl Outlet
Bedding
Undisturbed Soil
Backfill
Section A-A Plan View
Grade (Rim)
Rim elevations to match finished grade. PCS risers should NOT be field cut by Contractor.
Manhole Frame and Cover by Manufacturer.
(See Details)
Backfill shall extend at least 18 inch [457 mm] outward from Swirl Concentrator and for the full height of the Swirl Concentrator (including riser) extending laterally to undisturbed soils. (See MH Detail Below)
4 1/2" [114 mm]
1/2" [13 mm]
1" [25 mm]
Manhole Frame & Cover Detail
NTS
For Non-Traffic Areas Only
Soil
1" [25 mm]
Unless other traffic barriers are present, bollards shall be placed around access riser(s) in non-traffic areas to prevent inadvertent loading by maintenance vehicles.
Soil
Place small amount of concrete [3,000 psi [20 MPa] (min)] to support and level manhole frame.
DO NOT allow manhole frame to rest upon riser.
Riser
Frame
Cover 48"
[1219 mm] Min.
12" [305 mm]
Wrap Compressible Expansion Joint Material to a minimum
1-inch [25 mm] thickness around top of riser to allow transfer of inadvertent loading from manhole cover to concrete slab.
Backfill (90% Proctor Density)
Concrete Concrete8" [203 mm]
Gravel Backfill Gravel Backfill
Cover
Frame
1" [25 mm] Thick Expansion Joint
Material30" [762 mm] Riser
#4 [13 mm] Rebar @ 6" [152 mm]
Each Way
3,000 psi [20 MPa] (min) Concrete
Manhole Frame & Cover Detail For Traffic Loading Areas
NTS
If traffic loading (H-20) is required or anticipated, a 4-foot [1.22 m] diameter, 14-inch [356 mm] thick reinforced concrete pad must be placed over the Stormwater Treatment System Riser to support and level the manhole frame, as shown. The top of riser pipe must be wrapped with compressible expansion joint material to a minimum 1-inch [25 mm] thickness to allow transfer of wheel loads from manhole cover to concrete slab. Manhole cover shall bear on concrete slab and not on riser pipe. The concrete slab shall have a minimum strength of 3,000 psi [20 MPa] and be reinforced with #4 [13 mm] reinforcing steel as shown. Minimum cover over reinforcing steel shall be 1-inch [25 mm]. Top of manhole cover and concrete slab shall be level with finish grade.
Backfill (90% Proctor Density)
Aqua-Swirl Polymer Coated Steel (PCS) Stormwater Treatment System
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CU503
UTILITY DETAILS
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
01/12/2022 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
N
0 4020
CJ101
EROSION CONTROL PLAN
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
MILLER REMICK
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NJ 08034
856.429.4000
BENJAMIN HARLESS
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
11/30/2021 SLP DSMRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT CJ501
EROSION CONTROL
DETAILS
JS
SS
IG
CB
PO
GB
GB
SS
CB
IG
CA
JS
CA
IG
CB
SS
JS
JS
CB
JS
JS
JS
CB
JS
JS
CB
CB
PO
GB
GB
GB
DG
VD
HP
CK
SS
SS
IG
SS
IG
LM
LM
HP
SS
CA
IG
SS
IG
CB
SS
SS
IG
CA
CP
CP
LM
DG
DG
CP
IG
IG
SS
VD
GB
CP
GB
CP
IG
LM
LM
LM
PS
PS
PS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
LAND STEWARDS DESIGN GROUP
5022 ROCKVILLE ROAD
INDIANAPOLIS, IN 46224
317.771.5975
DAVID COUNSELL
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
12/06/2021 LOW BASRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
STATE OF
PE 11700768DA
VI
D
WAY
N E COUNSELLRE
GISTERED
INDIA NA
PROFESSI ONAL EN
GI
N
EE
R
PLANSCALE: 1" = 10'-0"
OVERALL PLANTING PLAN1
SCALE IN FEET
0 10' 20'
N
DECIDUOUS TREES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
CB Carpinus betulus 'Fastigata' / Common Hornbeam 1.5" CAL. B & B PER PLANS 8 6' CLEAR TO BASE CK Cornus kousa chinensis / Chinese Dogwood Tree 1" CAL. B & B PER PLANS 3 6' CLEAR TO BASE GB Ginkgo biloba / Ginkgo Tree 2" CAL. B & B PER PLANS 7 6' CLEAR TO BASE
EVERGREEN TREES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SIZING QTY REMARKS
JS Juniper scopulorum 'Skyrocket' / Skyrocket Juniper 8' CAL. B & B PER PLANS 11 6' CLEAR TO BASE PO Picea omorika / Serbian Spruce 8' CAL. B & B PER PLANS 2 6' CLEAR TO BASE
DECIDUOUS SHRUBS
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
CA Cornus alba 'Ivory Halo' / Red Twig Dogwood 3 GAL. PER PLANS 4 DG Deutzia gracilis 'Nikko' / Deutzia 3 GAL. PER PLANS 18 HP Hydrangea paniculata 'Quick Fire' / Panicle Hydrangea 5 GAL. PER PLANS 7 VD Viburnum dentatum 'Blue Muffin' / Arrowwood Viburnum 3 GAL. PER PLANS 8
EVERGREEN SHRUBS
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
IG Ilex glabra 'Compacta' / Inkberry 3 GAL. PER PLANS 48
ORNAMENTAL GRASSES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
CP Carex pensylvanica / Sedge FLAT 12" O.C. 49
PERENNIALS & GROUNDCOVER
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
LM Liriope muscari 'Big Blue' / Lily Turf FLAT 12" O.C. 120 PS Phlox subulata 'White Delight' / Creeping Phlox FLAT 12" O.C. 32 SS Salvia sylvestris 'May Night' / Meadow Sage 1 GAL. PER PLANS 70
OVERALL PLANTING SCHEDULE
PLANTING CODED NOTES
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIAL AND
GROUNDCOVER AREAS
DETAIL 1 - SHEET PL103
DETAIL 5 - SHEET PL103
DETAILS 3, 4 - SHEET PL103
DECIDUOUS TREE
DETAIL 5 - SHEET PL103
DETAIL 1 - SHEET PL103EVERGREEN TREE
KENTUCKY BLUEGRASS
SOD/SEED, TYP.
1. ALL BED LINES SHALL BE REVIEWED AND APPROVED BY THE CLIENT PRIOR TO INSTALLATION.
2. ALL TREE LOCATIONS SHALL BE REVIEWED AND APPROVED BY THE CLIENT PRIOR TO
INSTALLATION.
3. ALL PLANTING PROCEDURES ARE SUBJECT TO THE REVIEW OF THE CLIENT. THE CONTRACTOR
SHALL CORRECT ANY DEFICIENCIES FOUND AT NO ADDITIONAL COST TO THE CLIENT.
4. PLANT QUANTITIES LISTED IN SCHEDULE ARE PROJECT TOTALS, NOT SHEET. PLANS TAKE
PRECEDENT OVER SCHEDULE QUANTITIES. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL QUANTITIES ON PLANS.
5. IN THE EVENT THAT PLANT MATERIALS SPECIFIED ARE NOT AVAILABLE, CONTACT THE CLIENT FOR
APPROVED SUBSTITUTIONS. NO SUBSTITUTIONS AS TO TYPE, SIZE, OR SPACING OF PLANT
MATERIALS SPECIFIED ON THIS PLAN MAY BE MADE WITHOUT THE APPROVAL OF THE CLIENT.
6. VERIFY THAT ALL PLANTING PRODUCTS, PLANT MATERIAL, AND PLANT QUANTITIES DELIVERED TO THE SITE MATCH WHAT IS INDICATED ON THE PLANS AND SPECIFICATIONS. ALL PLANT MATERIAL DELIVERED TO THE SITE IS SUBJECT TO THE REVIEW OF THE CLIENT BEFORE, DURING AND AFTER
INSTALLATION.
7. PROTECT ALL PLANT MATERIAL DURING DELIVERY TO PREVENT DAMAGE TO ROOT BALLS,
TRUNKS, BRANCHES AND THE DESICCATION OF LEAVES. PROTECT ALL PLANT MATERIAL DURING
SHIPPING WITH SHADE CLOTH OR SHIP WITH ENCLOSED TRANSPORT. MAINTAIN PROTECTIONS
AND HEALTH OF PLANT MATERIAL STORED ON SITE. HANDLE ALL TREES WITH NYLON STRAPS. NO
CHAINS OR CABLES WILL BE ALLOWED. DAMAGED PLANTS WILL BE REJECTED AND REMOVED
IMMEDIATELY FROM THE SITE.
8. ALL PLANT MATERIAL SHALL BE NURSERY GROWN, WELL-FORMED, TRUE TO SPECIES, HARDENED OFF WITH VIGOROUS ROOT SYSTEMS, FULL CROWN AND CANOPIES, FREE FROM DISEASE, PESTS AND INSECTS, AND DEFECTS SUCH AS KNOTS, SUN SCALD, WINDBURN, LEAF DIS-COLORATION, IRREGULAR BRANCHING OR INJURIES, AND SHALL COMPLY WITH THE LATEST EDITION OF THE
AMERICAN STANDARD FOR NURSERY STOCK.
9. ALL PLANT MATERIALS, INCLUDING RELOCATED PLANT MATERIAL, SHALL BE PLANTED IN A
PROFESSIONAL MANNER TYPICAL TO THE INDUSTRY STANDARDS OF THE AREA TO ASSURE
COMPLETE SURVIVABILITY OF ALL INSTALLED PLANT MATERIALS AS WELL AS TO PROVIDE AN
AESTHETICALLY APPROVED PROJECT. CONTRACTOR SHALL REFER TO THE PLANTING DETAILS
FOR MINIMUM SIZE AND WIDTH OF PLANTING PITS AND BEDS, GUYING AND STAKING, MULCHING, AND OTHER PLANTING REQUIREMENTS.
10. ALL PLANTING AREAS SHALL BE WEED FREE PRIOR TO PLANTING INSTALLATION.
11. REMOVE ALL PLANTING AND LANDSCAPE DEBRIS FROM THE PROJECT SITE AND SWEEP AND
WASH CLEAN ALL PAVED AND FINISHED SURFACES AFFECTED BY THE LANDSCAPE INSTALLATION.
12. MULCH TO BE INSTALLED IN ALL PLANT BED AREAS AT 3" DEPTH.
GENERAL PLANTING NOTES
LP 101
PLANTING PLAN
PO
GB
GB
PO
GB
GB
GB
DG
VD
HP
CK
CP
CP
LM
DG
DG
CP
VD
GB
CP
GB
CP
IG
LM
LM
LM
PS
PS
PS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
LAND STEWARDS DESIGN GROUP
5022 ROCKVILLE ROAD
INDIANAPOLIS, IN 46224
317.771.5975
DAVID COUNSELL
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
12/06/2021 LOW BASRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
STATE OF
PE 11700768DA
VI
D
WAY
N E COUNSELLRE
GISTERED
INDIA NA
PROFESSI ONAL EN
GI
N
EE
R
PLANSCALE: 1" = 10'-0"
OVERALL PLANTING PLAN1
SCALE IN FEET
0 10' 20'
N
DECIDUOUS TREES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
CK Cornus kousa chinensis / Chinese Dogwood Tree 1" CAL. B & B PER PLANS 3 6' CLEAR TO BASE GB Ginkgo biloba / Ginkgo Tree 2" CAL. B & B PER PLANS 7 6' CLEAR TO BASE
EVERGREEN TREES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SIZING QTY REMARKS
PO Picea omorika / Serbian Spruce 8' B & B PER PLANS 2 6' CLEAR TO BASE
DECIDUOUS SHRUBS
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
DG Deutzia gracilis 'Nikko' / Deutzia 3 GAL. PER PLANS 18 HP Hydrangea paniculata 'Quick Fire' / Panicle Hydrangea 5 GAL. PER PLANS 4 VD Viburnum dentatum 'Blue Muffin' / Arrowwood Viburnum 3 GAL. PER PLANS 8
EVERGREEN SHRUBS
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
IG Ilex glabra 'Compacta' / Inkberry 3 GAL. PER PLANS 4
ORNAMENTAL GRASSES
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
CP Carex pensylvanica / Sedge FLAT 12" O.C. 49
PERENNIALS & GROUNDCOVER
CODE BOTANICAL NAME / COMMON NAME SIZE CONT SPACING QTY REMARKS
LM Liriope muscari 'Big Blue' / Lily Turf FLAT 12" O.C. 97 PS Phlox subulata 'White Delight' / Creeping Phlox FLAT 12" O.C. 32
OVERALL PLANTING SCHEDULE
PLANTING CODED NOTES
DECIDUOUS SHRUBS
EVERGREEN SHRUBS
PERENNIAL AND
GROUNDCOVER AREAS
DETAIL 1 - SHEET PL103
DETAIL 5 - SHEET PL103
DETAILS 3, 4 - SHEET PL103
DECIDUOUS TREE
DETAIL 5 - SHEET PL103
DETAIL 1 - SHEET PL103EVERGREEN TREE
KENTUCKY BLUEGRASS
SOD/SEED, TYP.
1. ALL BED LINES SHALL BE REVIEWED AND APPROVED BY THE CLIENT PRIOR TO INSTALLATION.
2. ALL TREE LOCATIONS SHALL BE REVIEWED AND APPROVED BY THE CLIENT PRIOR TO
INSTALLATION.
3. ALL PLANTING PROCEDURES ARE SUBJECT TO THE REVIEW OF THE CLIENT. THE CONTRACTOR
SHALL CORRECT ANY DEFICIENCIES FOUND AT NO ADDITIONAL COST TO THE CLIENT.
4. PLANT QUANTITIES LISTED IN SCHEDULE ARE PROJECT TOTALS, NOT SHEET. PLANS TAKE
PRECEDENT OVER SCHEDULE QUANTITIES. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING
ALL QUANTITIES ON PLANS.
5. IN THE EVENT THAT PLANT MATERIALS SPECIFIED ARE NOT AVAILABLE, CONTACT THE CLIENT FOR
APPROVED SUBSTITUTIONS. NO SUBSTITUTIONS AS TO TYPE, SIZE, OR SPACING OF PLANT
MATERIALS SPECIFIED ON THIS PLAN MAY BE MADE WITHOUT THE APPROVAL OF THE CLIENT.
6. VERIFY THAT ALL PLANTING PRODUCTS, PLANT MATERIAL, AND PLANT QUANTITIES DELIVERED TO THE SITE MATCH WHAT IS INDICATED ON THE PLANS AND SPECIFICATIONS. ALL PLANT MATERIAL DELIVERED TO THE SITE IS SUBJECT TO THE REVIEW OF THE CLIENT BEFORE, DURING AND AFTER
INSTALLATION.
7. PROTECT ALL PLANT MATERIAL DURING DELIVERY TO PREVENT DAMAGE TO ROOT BALLS,
TRUNKS, BRANCHES AND THE DESICCATION OF LEAVES. PROTECT ALL PLANT MATERIAL DURING
SHIPPING WITH SHADE CLOTH OR SHIP WITH ENCLOSED TRANSPORT. MAINTAIN PROTECTIONS
AND HEALTH OF PLANT MATERIAL STORED ON SITE. HANDLE ALL TREES WITH NYLON STRAPS. NO
CHAINS OR CABLES WILL BE ALLOWED. DAMAGED PLANTS WILL BE REJECTED AND REMOVED
IMMEDIATELY FROM THE SITE.
8. ALL PLANT MATERIAL SHALL BE NURSERY GROWN, WELL-FORMED, TRUE TO SPECIES, HARDENED OFF WITH VIGOROUS ROOT SYSTEMS, FULL CROWN AND CANOPIES, FREE FROM DISEASE, PESTS AND INSECTS, AND DEFECTS SUCH AS KNOTS, SUN SCALD, WINDBURN, LEAF DIS-COLORATION, IRREGULAR BRANCHING OR INJURIES, AND SHALL COMPLY WITH THE LATEST EDITION OF THE
AMERICAN STANDARD FOR NURSERY STOCK.
9. ALL PLANT MATERIALS, INCLUDING RELOCATED PLANT MATERIAL, SHALL BE PLANTED IN A
PROFESSIONAL MANNER TYPICAL TO THE INDUSTRY STANDARDS OF THE AREA TO ASSURE
COMPLETE SURVIVABILITY OF ALL INSTALLED PLANT MATERIALS AS WELL AS TO PROVIDE AN
AESTHETICALLY APPROVED PROJECT. CONTRACTOR SHALL REFER TO THE PLANTING DETAILS
FOR MINIMUM SIZE AND WIDTH OF PLANTING PITS AND BEDS, GUYING AND STAKING, MULCHING, AND OTHER PLANTING REQUIREMENTS.
10. ALL PLANTING AREAS SHALL BE WEED FREE PRIOR TO PLANTING INSTALLATION.
11. REMOVE ALL PLANTING AND LANDSCAPE DEBRIS FROM THE PROJECT SITE AND SWEEP AND
WASH CLEAN ALL PAVED AND FINISHED SURFACES AFFECTED BY THE LANDSCAPE INSTALLATION.
12. MULCH TO BE INSTALLED IN ALL PLANT BED AREAS AT 3" DEPTH.
GENERAL PLANTING NOTES
LP102
PLANTING PLAN DEDUCT
12" MIN. PLANTING MIXTURE FOR PLANTING
BED AREAS
TOP DRESS WITH 1" SHREDDED HARDWOOD
BARK MULCH, INSTALLED AFTER PLANTING
2" SHREDDED HARDWOOD BARK MULCH,
INSTALLED BEFORE PLANTING
GROUNDCOVER AS SPECIFIEDVARIES, SEE
SCHEDULE
SCALE: 1/2" = 1'-0"
GROUNDCOVER PLANTING3
BACKFILL PLANTING MIXTURE
FINISH GRADE
3" DEPTH MULCH
PLANT ROOT FLARE 1" ABOVE
FINISHED GRADE
ORNAMENTAL GRASS
OR PERENNIAL
6" MIN.
" M
IN
SCALE: 1/2" = 1'-0"
ORNAMENTAL GRASS & PERENNIAL PLANTING4
12" OC SQUARE FEET X 1.15
NOTE:
1. SPACING FOR GROUNDCOVERS,
SHRUBS, AND PERENNIALS
2. HARDWOOD BARK MULCH BETWEEN
PLANTS TO FILL PLANTING BED
CONTAINER
SHREDDED BARK MULCH
GROUNDCOVER OR SHRUB PIT
INCHES
BETWEEN
PLANTS
PLANT QUANTITIES
PER SQUARE FOOT
SCALE: 1/2" = 1'-0"
PLANT SPACING2
NOTES:
1. REMOVE ALL PLASTIC AND WIRE TAGS AND
CORDS.
2. PRUNE OUT ALL BROKEN BRANCHES WHEN
PLANTED.
3. SCARIFY SIDES AND BOTTOM OF PLANTING PIT.
4. REMOVE TOP 1
2 OF BURLAP AND WIRE BASKET
FROM ROOT BALL.
3"
D
EP
TH
O
F R
O O
T
BA
LL
6"
3x ROOT BALL DIA. MIN.
PLACE ROOT BALL ON TAMPED SOIL.
FASTEN TRUNK TO STAKE WITH RUBBER HOSE,
GUY WIRE AND REFLECTIVE FLAGGING
3" MULCH LAYER AS SPECIFIED.
TWO WOODEN STAKES SPACED EQUALLY
AROUND TREE, ANCHORED FIRMLY IN GROUND.
PLANTING BACKFILL MIXTURE.
SET TOP OF ROOT BALL 2-3" ABOVE
FINISH GRADE.
SCALE: 1/2" = 1'-0"
TREE PLANTING1
DO NOT CUT LEADER.
AFTER PLANTING, THIN BRANCHES BY 1/3,
RETAINING NORMAL TREE SHAPE.
3" HIGH EARTH SAUCER BEYOND
EDGE OF ROOT BALL.
SET ROOT FLARE 1" ABOVE FINISH GRADE
3" DEPTH SHREDDED
HARDWOOD BARK MULCH
ENTIRE PLANTING AREA
BACKFILL PLANTING MIXTURE
6" HAND TAMPED SETTING PAD OF
PLANTING MIXTURE; HAND TAMP
BELOW ROOTBALL AND SETTLE
PLANTING MIXTURE AROUND
ROOTBALL BY WATERING ONLY
SHRUB PIT WIDTH 2X
ROOTBALL DIA. MIN.
SCALE: 1/2" = 1'-0"
SHRUB PLANTING5
SCALE: NTS
CONCRETE PARK BENCH6
VENDOR: CROWD CONTROL WAREHOUSE
PRODUCT: PRECAST SOLID CONCRETE PARK
BENCH WITH BACK
SKU #: CCW-33-029-00540
COLOR: WHITE STANDARD ACID WASH
(OR APPROVED EQUAL)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
100% CONSTRUCTION
DOCUMENTS
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseARCHITECT/ENGINEER OF RECORD A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
GUIDON DESIGN INC.
1221 N. PENNSYLVANIA STREET
INDIANAPOLIS, IN 46202
317.800.6388
STACEY PAUL
CONSULTANT:
LAND STEWARDS DESIGN GROUP
5022 ROCKVILLE ROAD
INDIANAPOLIS, IN 46224
317.771.5975
DAVID COUNSELL
WEST HAVEN PARKING GARAGE
DESIGN
WEST HAVEN, CT
689-409
Project Director
12/06/2021 LOW BASRevisions: Date:
NON-SPRINKLEREDFACILITIES MANAGEMENT
STATE OF
PE 11700768DA
VI
D
WAY
N E COUNSELLRE
GISTERED
INDIA NA
PROFESSI ONAL EN
GI
N
EE
R
LP 501
PLANTING DETAILS
MISCELLANEOUS SYMBOLS
NORTH ARROW
GRIDLINES
EARTH
SECTION NUMBER
SHEET NUMBER
S101
S101
CALLOUT NUMBER
SHEET NUMBER
A
ELEVATION REFERENCE
LIMIT OF EXTENT
CONTINUOUS EXTENT
F ## COLUMN FOOTING NOTATION
GB ## GRADE BEAM NOTATION
P ## PIER NOTATION
B ## CONCRETE BEAM NOTATION
PC ## PILE CAP NOTATION
WF ## WALL FOOTING NOTATION
SHEAR WALL…